Home
Dimplex Compact Electric Flame Stove Heater - fireplace
Contents
1. from the terminal block Using pliers to hold the nuts on the inside of the stove remove the terminal block mounting screws Reassemble in the reverse order as above CS1205 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons TO REPLACE FLAME MOTOR FLAME ROD Remove the 8 fastening screws on the top panel and remove the top of the stove Lift glass out and store in a safe place Remove the log set by sliding to the rear of the stove and lifting out Remove the reflector rod from the flame motor by pulling the end of the rod to the left and separating it from the rubber sleeve Remove the rubber sleeve from the motor shaft Remove the 2 motor mounting screws and remove the flame motor Discard the old flame motor Lay the stove on its back with the front window facing upward Remove the bottom heater assembly cover being careful not to damage any of the wiring and lay it on the floor 10 Loosen the flame motor connections on the terminal block and remove the wires noting their original locations 11 Reassemble in the reverse order CS1205 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool of
2. bulbs and heating element to cool off to avoid accidental burning of skin Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons TO REPLACE HEATER ASSEMBLY Turn the stove over and place it top down Remove the bottom heater assembly cover being careful not to damage any of the wiring Remove the 4 heater retaining screws from the bottom of the heater assembly cover and move the heater to gain access to the heater connections being careful not to damage any of the wiring Disconnect the 2 heater switch leads from the heater Remove the wire nut and disconnect the thermal cut out wire Remove the 2 mounting brackets from the bottom of the old heater and install them on the new heater Reassemble in the reverse order as above x CS1205 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons TO REPLACE TERMINAL BLOCK Lay the stove on its back with the front window facing upward Remove the bottom heater assembly cover being careful not to damage any of the wiring and lay it on the floor Loosen the connections on the terminal block and remove the wires noting their original locations Remove the
3. the 5 fastening screws and lift the bulb shield out of the stove Examine the bulbs to determine which bulbs require replacement Hold the socket while unscrewing the bulb Hold the socket while screwing in the new bulb Replace the bulb shield and mirror and re install the top of the stove LOOSEN REMOVING AND REPLACING BULB WHILE HOLDING SOCKET LIGHT BULB REQUIREMENTS Quantity of 4 clear chandelier or candelabra bulbs with an E 12 small socket base 60 watt rating 6 CS1205 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons TO REPLACE ON OFF AND HEATER SWITCHES 1 Turn the stove over and place it top down 2 Remove the bottom heater assembly cover being careful not to damage any of the wiring 3 Remove the 4 heater retaining screws from the bottom of the heater assembly cover and move the heater to gain access to the switch connections Locate the switch to be replaced mounted on heater assembly cover and disconnect the wiring clips and connections noting their original locations Depress the retainer clips on the rear of the switch and push the switch out of the rear of the cover N CS1205 If unit was operating prior to servicing allow at least 10 minutes for light
4. OD LEVEL B REPLACEMENT PART REPLACEMENT PART NO Log Set Assembly 0477850100RP Flicker Motor 120V 2000210200RP Heater Assembly comes with cutout 2200491000RP Main On Off Switch 2800070700RP Heater Switch 2800070200RP Cord Set 120V 4100090100RP Moulded Lampholder 4200090100RP 5900250100RP i 5900530200RP 10 Foot 0477830159RP 11 Terminal Block 4000070100RP 12 Capacitor 2300030100RP OS Ol e Blade L Narro L AN CS1205 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to avoid accidental burning of skin Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons Light bulbs need to be replaced when you notice a dark section of the flame There are four bulbs under the log set which generate the flames and embers It is a good idea to replace all of the light bulbs at one time if they are close to the end of their rated life Group replacement will reduce the number of times you need to open the unit to replace the light bulbs LIGHT BULB REPLACEMENT Remove the 8 fastening screws on the top panel and remove the top of the stove Lift glass out and store in a safe place Remove
5. SERVICE MANUAL FOR COMPACT STOVE Model CS1205 X Dimplex 7400290000rev01 TABLE OF CONTENTS OPERATION PARTS DRAWING PARTS LIST WIRING DIAGRAM LIGHT BULB REPLACEMENT HEATER ON OFF SWITCH REPLACEMENT HEATER ASSEMBLY REPLACEMENT TERMINAL BLOCK REPLACEMENT FLAME MOTOR FLAME ROD REPLACEMENT POWER CORD REPLACEMENT X Dimplex PAGE 2 PAGE 3 PAGE 4 PAGE 5 PAGE 6 PAGE 7 PAGE 8 PAGE 9 PAGE 10 PAGE 11 Compact Stove Controls A Main on off switch 1 The fireplace has a manual power ON OFF switch located on the lower right side of the stove 2 To operate press the switch to turn the unit on or off B Low Heat Switch Press this switch to turn the stove to low heat C High Heat Switch Press this switch to turn the stove to high heat NY y Y RESETTING THE TEMPERATURE CUTOFF SWITCH Should the heater overheat an automatic cut out will turn the heater off and it will not come back on without being reset It can be reset by switching the MAIN ON OFF SWITCH to OFF and waiting 5 minutes before switching the unit back on CAUTION If you need to continuously reset the heater unplug the unit and call Dimplex North America Limited at 1 888 346 7539 CS1205 X Dimplex X Dimplex CS1205 REPLACEMENT PARTS COMPACT STOVE DIMPLEX CHARMGLOW PART NO 6902340100 M
6. f to avoid accidental burning of skin Disconnect power before attempting any maintenance or cleaning to reduce the risk of electric shock or damage to persons TO REPLACE THE POWER CORD Turn the stove over and place it top down Remove the bottom heater assembly cover being careful not to damage any of the wiring Remove the 4 heater retaining screws from the bottom of the heater assembly cover and move the heater to gain access to the switch connections Located and disconnect the power cord wiring connections from the heater and Main on off switch noting their original locations With needle nose pliers grasp the power cord strain relief grommet from inside the rear panel and push while twisting to remove Pull the power cord out through the hole in the rear cover Install the new cord set through the hole in the rear cover by placing the strain relief over the cord hold the strain relief with pliers and slide into mounting hole Connect all of the wiring connections in their original locations Reassemble in the reverse order as above
Download Pdf Manuals
Related Search
Related Contents
Samsung SP-46L6HX Εγχειρίδιο χρήσης エバラ 水冷式ポンプコントローラ Valueline VLAP20100B10 エコマーク「基準審議委員会」(第4回)議事要旨 manual de instalación y mantenimiento de controlador Open Access version via Utrecht University Repository 前払金 無し 部分払 有り 賃貸借期限 平成32年12月31日 納入 DESCASCARADORA DE MANÍ User Manual Copyright © All rights reserved.