Home

Enterasys (ER16-GTX32

image

Contents

1. Offline On Amber The module is offline powered down and ready to hotswap Per Port Green The port transmitted a packet The OCMAC controls Transmit this LED Orange he port transmitted a flow control packet The T OCMAC controls this LED Per Port Green The port received a packet The OCMAC controls this Receive LED Orange The port received a flow control packet The OCMAC controls this LED Per Port Link Green The port hardware detected a cable plugged into the port and established a good link Off No link exists from the port Per Port Green Autonegotiation completed successfully and the phy is Quality attempting to establish a link This LED remains green while the link operates with good signal to noise ratio Fast blink Low signal to noise ratio close to data errors Slow blink Receive bit errors detected Off Autonegotiation is in progress or the phy cannot receive packet data Options Available The ER16 GTX32 04 provides switching and routing on hardware thereby eliminating the performance bottleneck caused by a single processor The module supports application switching i e Network Address Translation Server Load Balancing Per Flow Rate Limiting Access Control Lists and full RMON RMON 2 and extra features like the Local Hardware Routing Table Port Rate Limiting Aggregate Rate Limiting and Jumbo Frames that are essential for Application Service Providers Multi Dwelling
2. Unit MDU Service Providers and Large Enterprise Networks The ER16 GTX32 04 offers ten times the bandwidth available through the existing Category 5 infrastructure and interoperates with all existing X Pedition Router modules This allows network managers to leverage their existing cabling infrastructure and equipment without an extensive upgrade INSTALLING THE MODULE ELECTRICAL HAZARD Only qualified personnel should perform installation procedures Handling the Module CAUTION The ER16 GTX32 04 is designed for slots 1 7 or 9 16 only and is easily damaged by electrostatic discharge To prevent electrostatic damage observe the following guidelines Do not remove the module from its packaging until you are ready to install it Do not touch any of the module s pins connectors or components Hold the module only by its edges or front panel Wear an anti static wristband connected to a suitable earth ground whenever handling the module Store or transport this module only in appropriate anti static packaging Equipment Checklist After unpacking the ER16 GTX32 04 check the contents of the box to be sure you received the following items One ER16 GTX32 04 module in anti static bag One disposable anti static wristband Tools This installation requires the following tools Flathead screwdriver me Anti static wristband Preliminary Setup Firmware Image Requirements
3. 6 EEC EN 55022 EN 61000 3 2 EN 61000 3 3 EN 55024 AS NZS 3548 and VCCI V 3 ER16 GTX32 04 The ER16 GTX32 04 is a copper based 1000Base T Gigabit Ethernet module for the Enterasys X Pedition platform The ER16 GTX32 04 provides four ports of 1000Base T switched and routed connectivity through Category 5 RJ45 connectors and is ideal for high speed collapsed backbones and server farm connections The ER16 GTX32 04 delivers full function Layer 2 Layer 3 and Layer 4 switching and routing SPECIFICATIONS Ports 4 1000Base T Ports ASIC Type T Series Network Interface RJ 45 100m Cat5 UTP Cabling per ANSI TIA EIA 568 A Number of Flows Routes Layer 2 Entries 512 000 memory size 64 MB Layer 3 Entries 512 000 memory size 32 MB Switch Method Address based and Flow based Physical Dimensions Size 45 16 cm H x 2 54 W x 35 24 D 17 78 in H x 1 W x 13 88 D Weight 2 3 kg 5 0 lbs Power Consumption BTU hr 362 6 AC Volt Amps 107 31 Temperature Operating 41 to 104 F 5 to 40 C Storage 22 to 164 F 30 to 73 C Humidity 15 to 90 non condensing CONNECTIVITY GUIDELINES Table 1 Recommended Cable Types and Specifications Cable Type Max Length Connector 100Base TX Cat 5 100 ohm UTP 100 m 328 ft RJ 45 LEDs Table 2 LED Indicators LED Condition Status Online On Green The module is online and ready to receive process and send packets if configured to do so
4. NOTICE Enterasys Networks and its licensors reserve the right to make changes in specifications and other information contained in this document without prior notice The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made The hardware firmware or software described in this manual is subject to change without notice IN NO EVENT SHALL ENTERASYS NETWORKS AND ITS LICENSORS BE LIABLE FOR ANY INCIDENTAL INDIRECT SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO LOST PROFITS ARISING OUT OF OR RELATED TO THIS MANUAL OR THE INFORMATION CONTAINED IN IT EVEN IF ENTERASYS NETWORKS AND ITS LICENSORS HAVE BEEN ADVISED OF KNOWN OR SHOULD HAVE KNOWN THE POSSIBILITY OF SUCH DAMAGES Enterasys Networks Inc 35 Industrial Way Rochester NH 03866 5005 2001 by Enterasys Networks Inc All Rights Reserved Printed in the United States of America Order Number 9033770 November 2001 X Pedition and Enterasys Networks are registered trademarks of Enterasys Networks or its licensors All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies FCC NOTICE This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause unde
5. SHOOTING Proper Boot Sequence Offline LED lights at power up Port LEDs flicker briefly during system boot while ports initialize Online LED turns on once module is active Common Errors The ER16 is not powered up The module is not properly seated in the slot Connectors on both ends of the cable are not properly engaged The copper cable did not click into place or is not properly seated Ensure that the attached device is configured to match the configuration mode of the ER16 module e g autonegotiation enabled Helpful CLI Commands for Debugging System show hardware System show version System show bootlog ADDITIONAL INFORMATION For additional information about installing this module or to learn more about what capabilities are included in the firmware release you are using visit the Enterasys Networks web site Getting Help For additional support related to the Common CLI syntax or this document contact Enterasys Networks using one of the following methods World Wide Web http www enterasys com Phone 603 332 9400 Internet mail support enterasys com FTP ftp ftp enterasys com Login anonymous Password your email address To acquire the latest image for http Awww enterasys com download this product and any available release notes Additional documentation http www enterasys com support manuals To send comments or suggestions concerning this d
6. Version 9 0 0 0 or later Default Module Settings The default mode for each port on the ER16 is Full duplex 1000 mbs autonegotiation on To view the current mode for a particular port enter the following where x is the chassis slot that contains the line card and y is a specific port number on the card XP port show port status gi x y CLI Setup Enter the following commands at the CLI before implementing any configurations 1 Enable gt Configure gt lt Enter gt 2 Once you reach the configuration prompt you can configure the ER16 GTX32 04 using CLI commands as described in the X Pedition CLI manual Enter the character to view the options available to you in configuration mode Connector Pin Assignments The connector pins are assigned as follows Table 3 RJ45 Connector Pin Assignments Pin Connection 1 TRDO Diff Output TRDO Diff Output TRD1 Diff Output TRD2 Diff Output TRD2 Diff Output TRD Diff Output TRD3 Diff Output co y A mY A WwW N TRD3 Diff Output Hotswap You may install this module into a live system without powering off the device However do not remove an active module from a live system except under the following conditions Press the Hotswap button The Online LED will turn off and the Offline LED will turn on Remove the module OR Enter the following from the CLI and click enter Enable gt System g
7. n Technology Equipment VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions CORB PHARRESERESA EM HBR VCCI ORF HOS TDIRZABRHAE CT ZOREC RERE CHATS CMR HHEUPSMITLEMHOVETF TORETE IERA R ET SLIBRENSTEMHOVET CLASS A ITE NOTICE WARNING This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures DECLARATION OF CONFORMITY Application of Council Directive s 89 336 EEC 73 23 EEC Manufacturer s Name Enterasys Networks Inc Manufacturer s Address 35 Industrial Way PO Box 5005 Rochester NH 03867 European Representative Address Enterasys Networks Ltd Nexus House Newbury Business Park London Road Newbury Berkshire RG14 2PZ England Conformance to Directive s Product Standards EC Directive 89 336 EEC EC Directive 73 23 EEC EN 55022 EN 55024 EN 60950 EN 60825 Equipment Type Environment Networking Equipment for use in a Commercial or Light Industrial Environment Enterasys Networks Inc declares that the equipment packaged with this notice conforms to the above directives AGENCY STANDARDS Safety Meets the requirements of UL 1950 CSA 22 2 No 950 73 23 EEC EN 60825 EN 60950 and IEC 950 Electromagnetic Compatibility Compliant with the requirements of FCC Part 15 CSA C108 8 89 33
8. ocument contact the Technical Writing Department via the following email address TechWriting enterasys com Please include the document Part Number in the email message Before contacting Enterasys Networks for technical support have the following information ready Your Enterasys Networks service contract number A description of the failure A description of any action s taken to resolve the problem e g changing mode switches rebooting the unit The serial and revision numbers of all involved Enterasys Networks products in the network A description of your network environment layout cable type etc Network load and frame size at the time of trouble if known ER16 GTX32 04 Quick Start Web Site http Awww enterasys com 9033770 ENTERASYS NETWORKS n
9. sired operation NOTE This equipment has been tested and found to comply with the limits for a class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment uses generates and can radiate radio frequency energy and if not installed in accordance with the operator s manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense WARNING Changes or modifications made to this device which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment INDUSTRY CANADA NOTICE This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada VCCI NOTICE This is a class A product based on the standard of the Voluntary Control Council for Interference by Informatio
10. t Hotswap gt Out gt Slot gt The Online LED will turn off and the Offline LED will turn on Remove the module Instructions CAUTION Before performing any upgrade or installation ensure that you are properly grounded to avoid electrostatic discharge 1 Ifacoverplate is installed in the slot where you will insert the module remove the coverplate loosen the screws on the ejectors until the screws pop out then open the ejectors and pull out the plate 2 Open the ejectors at the top and bottom of the ER16 GTX32 04 3 Align the metal backpanel of the module with the card guides at the top and the bottom of the slot opening as shown in Figure 1 NOTE Make sure that the metal backpanel of the module not the circuit card is between the card guides Check both the upper and lower tracks 4 Slide the module all the way into the slot firmly but gently pressing to ensure that the pins on the back of the ER16 GTX32 04 are completely seated in the backplane 5 To lock the ER16 GT X32 04 into the slot close the ejectors Using a flathead screwdriver tighten the screw on each ejector Figure 1 Install the ER16 GTX32 04 Rotate ejector to lock in place Ejector Circuit Card Metal Backpanel ect ec i Card Guides RxO OTx Quality OLink Status LEDs CPU Board Status Indicators and Hotswap button TROUBLE

Download Pdf Manuals

image

Related Search

Related Contents

DM-C2 取扱説明書 Rev1.2  Nevelkanon De-Dust Pico  NEC NEAX2400IMX User's Manual    ANT180-L Series Stage User`s Manual  仕 様 書  NEC NP-M322W Installation and Setup Guide  COMMERCIAL AIR CONDITIONER Service Manual  Kent Express November Promotional Offers  K61 Service Manual ()  

Copyright © All rights reserved.
Failed to retrieve file