Home

Whirlpool 3QACM07XD2 Air Conditioner User Manual

image

Contents

1. ONLY Modifying the air direction The air output louvers at the top of the air conditioner s front panel control the direc tion of the cooled air The louvers may be adjusted left right up or down Using the exhaust door The exhaust door allows the air conditioner to draw stale or smoky air from the room xhaust Pull to open exhaust door or push to close Fxhau door mee control PERSONALIZING THE FRONT PANEL Personalizing the Front Panel available on select models The appearance of the front panel can be customized to suit your tastes or to match the room The panel has a clear protective plastic cover that you can remove Then place wallpaper fabric pictures etc in the open area and replace the protective cover Removing the protective cover 1 Place the flat edge of a screwdriver into the 1 mm gap between the protective cover and the front panel 2 Carefully pry off the protective cover Replacing the protective cover 1 Insert tabs on one side of the protective cover into the tabs in the corresponding side of the front panel 2 Snap the other side of the cover into place _CARING FOR YOUR AIR CONDITIONER Caring for Your Air Conditioner In This Section Page Caring for the control panel 8 Caring for the slide out air filter Caring for the front panel etc 8 Performing annual coil cleaning Proper maintenance of y
2. ITY OF THIS OR ANY OTHER APPLIANCE THE FUMES CAN CREATE A FIRE HAZARD OR EXPLOSION SAVE THESE INSTRUCTIONS Consumer responsibilities Please The steps on pages 10 13 must be performed by a qualified installer e Be sure the air conditioner is the correct voltage and size for the area you want to cool e Be sure the air conditioner is installed in accordance with all national electrical codes and wiring regulations e Use the air conditioner only for the uses described in this manual e Be sure the air conditioner is not used by anyone unable to operate it properly e Maintain the air conditioner properly e If power cord is damaged be sure it is replaced or repaired by an authorized service technician Also please DO NOT use sharp instru ments flammable fluids or abrasive cleaners These can damage the surface of the air conditioner Parts and Features This section contains captioned illustrations of your air conditioner Please use them to become familiar with where the parts and features are located and what they look like Air conditioner Outside air intake Exhaust door Air output Protective plastic louvers control louvers cover for A i front panel i available on j select models Era Model and seria Control pane Control panei Inside air intake Stide out air filter number label door louvers handle OPERATING YOUR AIR Operating Your Air Conditioner In
3. This Section Turning the air conditioner on off Modifying the fan speed Modifying the temperature Using the FAN ONLY Cycle Modifying the air direction Using the exhaust door Operating your air conditioner properly is essential to obtain the best possible results This section tells you about each cycle and how to operate it Turning the air conditioner on off To turn the air conditioner on e Set the POWER Switch to ON To turn the air conditioner off Set the POWER Switch to OFF IMPORTANT After turning the unit off wait approximately 3 minutes before turning it back on If you don t wait 3 minutes the air conditioner will try to start but turn itself off ON Modifying the fan speed Use the FAN SPEED Switch to select a desired fan speed Use the speeds as follows HI Speed Use for maximum cooling LOW Speed Use for sleeping comfort FAN SPEED OPERATING YOUR AIR CONDITIONER VTS Oe Mn REO Modifying the temperature Set the TEMP Control to your desired COOLER setting e Turn clockwise for more cooling FAN e Turn counterclockwise for less cooling ONLY You will need to experiment to find the setting which suits you best Using the FAN ONLY Cycle The FAN ONLY Cycle circulates the room COOLER air without cooling it However if the room temperature rises above 32 C 90 F the FAN compressor will turn on and cool the room
4. Wairkpdot Owner s Note to You Important Safety Instructions Parts and Features Operating Your Air Conditioner Personalizing the Front Panel Caring for Your Air Conditioner Installing Your Air Conditioner 10 Troubleshooting 14 Obtaining Service 14 ROOM AIR CONDITIONERS Part No 1181126 A Note to You Thank you for buying a Whirlpool appliance You purchased a quality world class home appliance Years of engineering experience went into its manufacture To ensure you operate and care for your appliance properly we devel oped this Owner s Manual It is full of valuable information on how to operate and maintain your appliance properly and safely Please read it carefully Your safety is important to us This guide contains safety symbols and statements Please pay special attention to these symbols and follow any instructions given Here is a brief explanation of the use of each symbol AWARNING E15 A This symbol represents the rated current of appropriate fuse link in This symbol alerts you to such dangers amperes as personal injury burns fire and This symbol represents the Sencar shock amp EARTHING TERMINAL Please complete this section lf you ever have a question concerning this appliance or if you need service first see Obtaining Service on page 14 If service is required you will need to know your appliance s complete model and serial number You can find this information
5. dry completely before replacing it 4 Slide filter up into the slot until filter is completely fitted NOTE You may need to clean the air filter more often if it is subjected to heavy dust dirt etc Performing annual coil cleaning The coils in your air conditioner need to be Contact an authorized service company cleaned annually to prolong the air to perform this annual maintenance conditioner s life and its cooling efficiency As air moves over the coils they collect dirt sand leaves insects algae and other air borne particles INSTALLING YOUR AIR CONDITIONER Installing Your Air Conditioner In This Section General information Installation procedure General information Location Your air conditioner will work well in any location However the preferred location for the unit is on a wall out of direct sunlight The location should also provide e Adequate support for the weight of the unit e An electrical outlet within reach of the power supply cord Free movement of air to the room s to be cooled e Free movement of air to the air intake louvers inside and outside The power supply cord can be fed through either side of the front panel Electrical outlet must be available within reach of the power supply cord DO NOT use an extension cord Cabinet dimensions The cabinet dimensions are as follows WIE seiticslevedesibivtsaatecrecncipetane ives 470 m
6. e a properly grounded 3 prong wall receptacle installed by a qualified electrician Power supply DO NOT disconnect the air conditioner from its electrical supply DO NOT use an electri cal outlet that can be turned off with a switch 14 INSTALLING YOUR AIR CONDITIONER Installation procedure 1 Remove the front panel Remove tape if 4 Slide the chassis out of the cabinet any Lift panel and take it off the cabinet 5 install the drain plug and drain cup 2 Remove the shipping brackets 2 accessory parts to rear of cabinet Slide Remove the cabinet ground screw 1 drain cup down into rear support between and disconnect the green and yellow grooves in cup grounding wire NOTE Attach drain plug and drain cup assemblies and attach hose before sliding unit into cabinet Instali re Install Drain Drain cup 7 Plug plug Screws 5 od 6 Fix the cabinet to the support frame A Ua 12 Slide the chassis into the cabinet Install the cabinet seal accessory part between the cabinet and the frame wall 8 Reinstall the shipping bracket and attach with screws 2 9 Reconnect the green and yellow grounding wire AWARNING Electrical Shock Hazard Connect ground wire when unit is in cabinet Failure to do so will result in electrical shock INSTALLING YOUR AIR CON 19 Remove slide out filter from front panel Replace the front panel Insert tabs into slots
7. m Height s2sscointeisvatcnaasnruccacuptegimtetoccde 350 mm Depth with front panel sesse 600 mm D Clearance e Keep outside air intake louvers clear Front cover F Outside air intake louvers e If the wall is greater than 290 mm thick cut the wall back on a 45 angle if possible e Allow sufficient clearance around the sides and rear of the unit minimum clearance 350 mm iminimum clearance Provide adequate drainage Tilt unit toward outside so unit drains to the rear E y 5 to 10 mm Install drip cup if required Provide additional support for unit if required Support frame INSTALLING YOUR AIR CONDITIONER Provide adequate clearance so the air filter can be removed from the bottom of the front panel Must be able to remove air filter Electrical requirements Check the model and serial number label to determine the electrical requirements of your unit ALL units must use a time delay fuse or circuit breaker Grounding method Your air conditioner is equipped with a power supply cord containing a 3 prong grounding plug To minimize possible electrical shock hazard the power supply cord must be plugged into a mating 3 prong grounding type wall receptacle which is grounded in accordance with all applicable codes If a mating wall receptacle is not available it is the personal responsibility and obligation of the customer to hav
8. nexpectedly Delay Stop is programmed See Deluxe Remote Control Owner s Manual for more information on these TIMED MODE operations Obtaining Service If the problem is not due to an item listed in the chart above Contact the dealer from whom you pur chased the unit an authorized Whirlpool service company or refer to the guarantee booklet included with your product Registered Trademark of Whirlpool U S A 14
9. on the model and serial number label see diagram on page 4 For your convenience we included a place below for you to record these numbers the purchase date from the sales slip and your dealer s name and telephone number Keep this book and the sales slip together in a safe place for future reference Model Number Dealer Name Serial Number Dealer Phone Purchase Date IMPORTANT After turning the unit off wait approximately 3 minutes before turning it back on If you don t wait 3 minutes the air conditioner will try to start but turn itself off IMPORTANT SAFETY INSTRUCTIONS Important Safety Instructions AWARNING To reduce the risk of fire electrical shock or personal injury when using your air conditioner follow these basic safety precautions Read all instructions before using your air conditioner Complete the installation requirements as described in Installing Your Air Conditioner on pages 10 13 e Do not allow children to operate or play with the air conditioner e Do not use an extension cord with this or any other appliance e Plug the air conditioner into a grounded electrical outlet only e Do not operate the air conditioner with the front panel removed e Never clean air conditioner parts with flammable fluids The fumes can create a fire hazard or explosion e FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPOURS AND LIQUIDS IN THE VICIN
10. on the top flange of the cabinet Rotate the front panel downward until it fits snugly between cabinet side flanges Secure front panel with 2 round head screws accessory parts Replace slide out air filter NOTE Make sure the Exhaust Door Control lever is between the frame and the first air discharge louver before securing front panel with screws 13 TROUBLESHOOTING OBTAINING SERVICE Troubleshooting Performance problems often result from little things you can find and fix yourself without tools of any kind Check the chart below for problems you can fix It could save you the cost of a service call PROBLEM POSSIBLE SOLUTION Make sure unit is plugged into a live circuit with proper voltage Check if a household fuse has blown or the circuit breaker tripped Make sure unit is turned on See if the local power has failed Wait at least 3 minutes after turning unit off before trying to restart Unit blows Check if a household fuse has blown or the circuit breaker tripped household fuses or trips circuit breakers Make sure unit is plugged into a live circuit with proper voltage Make sure an extension cord is not being used Wait at least 3 minutes after turning unit off before trying to restart Remote control Replace batteries If the remote control still doesn t work call your doesn t work authorized service company Unit stops starts Deluxe Remote Control models only Check if Delay Start or u
11. our air conditioner ensures longer life and lower operating costs This section tells you how to clean your air conditioner and perform general maintenance You can always call an authorized Whirlpool service company for annual service Caring for the control panel e Wipe clean with a soft damp cloth Make sure the cloth is not dripping wet The control panel door If the control panel door pops out of place it pops back into place easily 1 Place the left door pin into the hole on the left side of the door opening 2 Flex the door slightly 3 Snap the right door pin into place Caring for the front panel etc Perform basic cleaning of the front panel by wiping it with a soft dry cloth NOTE Do not use abrasive or harsh cleaners on the front panel especially on the protective plastic cover CARING FOR YOUR AIR CONDITIONER Caring for the slide out air filter The air filter helps remove dust lint and other particles from the air The air filter is cleanable Check the air filter every few weeks to see if it needs cleaning 1 Grasp the bottom edge of the front panel with both hands as shown There are 2 finger notches in the front panel behind the filter handle 2 Slide the air filter forward and down until it releases from the front panel 3 Clean the air filter using a vacuum cleaner OR If it is very dirty wash the filter with warm water and a mild detergent Allow filter to air

Download Pdf Manuals