Home
Tripp Lite 230V Power Supply User Manual
Contents
1. Source Voltage Matching Switch Set the source voltage matching switch to either 208 220 or 240 volts to match the input voltage being used Basic Operation Indicator Lights All indicator light descriptions apply when the Line Conditioner is plugged into a wall outlet and turned on Available on select models only A green NORM light will turn ON whenever your Line Conditioner is plugged in and receiving nominal AC line voltage Yellow lights labelled LOW or BOOST and HIGH or TRIM will turn ON when incoming voltage is above or below nominal AC line voltage Red lights labelled VERY HIGH or VERY LOW will turn ON when incoming voltage is substantially above or below nominal AC line voltage A green LINE Ok light will turn ON when AC power is present and no wiring faults are detected When this light is illuminated AC power is accept able for connected equipment A red LINE FAULT light will turn ON to indicate a wiring fault has been detected The condition should be investigated and repaired by a qualified technician as soon as possible A loose wall outlet may cause this light to come ON Your Line Conditioner will identify most common wiring faults but not necessarily every possible type of fault Other Features AC Receptacles The receptacles provide your connected equipment with AC line power during normal operation They adjust incoming voltage to provide equip ment with
2. 27 1 Uniplug LR 1000 1000 230 50 60 2 4 NEMA 5 15R 340 20 dB 17x 15x 17 3 6 1 Uniplug LR 2000 2000 230 50 60 2 2 NEMA 5 15R 1360 50 dB 17x 15x17 45 2 NEMA 6 15R 2 IEC 320 1 Uniplug INT T Voltage Range 168 278VAC nominal output LR2000 nominal output can be set to 208 220 or 240VAC Cordsets are IEC 320 female to NEMA 5 15 male LR2000 cordset is IEC 320 female to NEMA 6 15 male 2 Year Limited Warranty TRIPP LITE warrants its products to be free from defects in materials and workmanship for a period of two years from the date of initial purchase TRIPP LITE s obligation under this warranty is limited to repairing or replacing at its sole option any such defective products To obtain service under this warranty you must obtain a Returned Material Authorization RMA number from TRIPP LITE or an authorized TRIPP LITE service center Products must be returned to TRIPP LITE or an authorized TRIPP LITE service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warran ty does not apply to equipment which has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HEREIN TRIPP LITE MAKES NO WARRANTIES EXPRESS OR IMPLIED INCLUDING WARRANTIES OF
3. MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically TRIPP LITE is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise The policy of TRIPP LITE is one of continuous improvement Specifications are subject to change without notice TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com 2009XXXXX 93 1512_EN
4. nominal 220 240V power The receptacles also protect your equipment against damaging surges and line noise eliminating the need for external surge suppression Note As the Line Conditioner corrects fluctuating input voltages the unit will make a gentle clicking sound The frequency of the clicking will depend on the quality of the utility power in your particular area The clicking is normal and indicates the Line Conditioner is compensating for fluctuating input voltages as described in this manual Circuit Breaker Available on select models If the rated capacity of the Line Conditioner is exceeded at any time the circuit breaker will open trip Remove the overload and let the circuit breaker cool for one minute Reset the circuit breaker by pushing in the plunger Service If returning your Line Conditioner to Tripp Lite or an authorized Tripp Lite service cen ter please carefully pack the it using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the Line Conditioner is within the 2 year warranty period enclose a copy of your sales receipt Specifications Output Voltage Cord Number Surge High Frequency Dimensions Shipping Wattage Frequency Length Type of Energy Rating Noise ee HxWxD Weight Model Continuous Hz m utlets Joules 1 MHz cm kg LR 604 600 230 50 60 2 4 NEMA 5 15R 340 20 dB 15x 12x 13
5. Owners Manual TRIPP LITE LINE POWER PROTECTION CONDITIONERS 1111 W 35th Street Chicago IL 60609 USA Customer Support 1 773 869 1234 www tripplite com 220 240V 50 60 Hz ESPANOL p 6 FRANCAIS p 11 DEUTSCH p 16 Safety p 2 Quick Installation Basic Operation p 4 Service p 5 Specifications p 6 Safety This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Line Conditioners Line Conditioner Location Warnings Install your Line Conditioner indoors away from excess moisture or heat dust or direct sunlight For best performance keep the indoor temperature between 0 C and 40 C between 32 F and 104 F Leave adequate space around all sides of the Line Conditioner for proper ventilation Line Conditioner Connection Warnings Connect your Line Conditioner to a three wire grounded AC power outlet Do not remove or modify the ground pin of the Line Conditioner s plug Do not use two prong adapters with the Line Conditioner s plug Do not plug your Line Conditioner into itself this will damage the Line Conditioner and void your warranty If you are connecting your Line Conditioner to a motor powered AC generator the generator must provide clean filtered computer grade output Use care when connecting country specific plugs to selected 220 240V 50 60 Hz Line Conditioners Hot 1 and Hot 2 may be reve
6. rsed When using a French CEE7 7 plug always use the separate grounding pin supplied with the unit When using a Schuko CEE7 4 plug an ungrounded condition will exist unless separate grounding to the rear of the Line Conditioner is provided by the user Equipment Connection Warning Do not use Line Conditioners for life support applications in which a malfunction or failure of a Line Conditioner could cause failure or significantly alter the performance of a life support device Line Conditioner Maintenance Warning Line Conditioners require no maintenance Keep the Line Conditioner dry at all times DO NOT open the unit for any reason Quick Installation 220 240V 50 60 Hz Connect your computer or electronics to the Line Conditioner and the Line Conditioner to an electrical outlet A Exchange the Line Conditioner s cord with your equipment s cord Connect the Line Conditioner cord s male plug into a Line Conditioner receptacle Connect its female plug into the equipment s male input B Connect the equipment cord s male plug into a wall outlet Connect its female plug into the line conditioner s male input Connect additional equipment to the Line Conditioner in the same manner Additional cords and receptacle adapters are available to accommodate most outlet configurations Turn on your Line Conditioner s power switch Note select models