Home
ReliOn Thermometer Thermometer User Manual
Contents
1. 34 C Lo or gt 109 4 F 43 C Hi Thermometer beeps once for each memory recall and when unit automatically turns off Short rapid continually beeps indicate battery is low 60 8 F to 104 0 F 16 0 C to 40 0 C at relative air humidity not condensing of up to 95 4 0 F to 122 0 F 20 0 C to 50 0 C Automatic shut off after approximately 1 minute of non use 1 each CR2032 battery 4 1 2 L x 1 3 8 W x 1 H 11 5cm x 3 5cm x 2 5cm With battery 1 6 ounces 45 grams Storage case Instruction Guidebook Quick Start Guide one CR2032 battery Complies with US ASTM E 1965 98 91 032 144 107 8 06 2006 ReliOn INSTRUCCIONES Termometro de O do S rvase leer completamente esta gu a detallada antes de operar la unidad y GU A DETALLADA Ingl s Espa ol O Garant a Limitada de Cinco A os Su Term metro de O do Instant neo est garantizado de estar libre de defectos de fabricaci n durante un per odo de cinco a os a partir de la fecha de la compra bajo condiciones de uso normales Esta garant a limitada no corresponde a aplicaciones cl nicas ni comerciales En caso de falla de la unidad durante el per odo de garant a devu lvala con el franqueo previamente pagado m s US 5 00 en concepto de gastos de env o y seguro a Departamento de Reparaciones 1931 Norman Drive South Waukegan IL 60085 Al devolver un producto tambi n incluya por favor una carta con su n
2. Recuerde que las temperaturas pueden variar de 97 0 F a 99 0 F 36 1 C a 37 2 C y a n as considerarse normales Las variaciones en la temperatura pueden atribuirse a factores tales como la hora del d a el nivel de actividad el ejercicio y dem s actividades Sin embargo a diferencia de las temperaturas orales las mediciones en el o do no se ven afectadas por factores tales como el fumar hablar y beber 6 No camine corra o hable durante la toma de la temperatura 7 Limpie la punta del sensor antes y despu s de cada uso 8 Guarde la unidad en el estuche protector cuando no la utilice 9 1 napa No toque el sensor con los dedos 0 No exponga la unidad a la luz del sol directa polvo o humedad Evite las temperaturas extremas 11 Evite dejar caer el term metro o los grandes golpes 12 No intente desarmarlo excepto para cambiar la bater a 13 Si no se logra una medici n deber reemplazarse la unidad NOTA El desempe o de este dispositivo puede verse afectado si se opera fuera de los niveles de temperatura y humedad recomendados si se almacena bajo niveles de temperatura y humedad fuera de los recomendados si el term metro se somete a un golpe mec nico se lo deja caer si la temperatura del paciente est por debajo de la temperatura ambiente O Limpieza y Almacenamiento A fin de garantizar mediciones exactas mantenga la lente del medidor limpia y sin rayaduras Las huellas digitales y la cera en
3. 2 Limpie la lente del sensor antes y despu s de cada uso C mo Cambiar de Modo Las lecturas de temperaturas pueden visualizarse en gra D 98 Fe dos Fahrenheit o Celsius Para conmutar entre F or C presione y mantenga en esa posici n el bot n SCAN Sin liberar ste presione tambi n el bot n M para cambiar Fig 1 entre modos Figs 1 y 2 GB Nake V0 Fig 2 Como Invocar a las Mediciones en la Memoria Las ultimas 10 mediciones tomadas quedan NET gim almacenadas en la memoria autom ticamente Para WI F invocar a las mediciones presione el bot n SCAN para encender la unidad Despu s de escuchar la S mbolo de Fig 1 se al audible pulse el bot n M para ver las Memoria g mediciones en la memoria Contin e presionando Numero de dicho bot n para ver la siguiente medici n almacenada anteriormente Fig 1 La unidad sonar cada vez que se vea el registro de una medici n C mo Cambiar la Bater a Su Term metro de O do requiere de una bater a de litio tipo CR2032 Es necesario cambiar la bater a cuando en el visor se visualice el s mbolo de poca bater a Para cambiar la bater a 1 Deslice la cubierta de bater a para retirarla 2 Con una herramienta de punta no met lica retire la bater a con sumo cuidado e inserte la nueva con el lado positivo hacia arriba 3 Vuelva a colocar la cubierta de la bater a NOTA Desh gase adecuadamente
4. detr s y ligeramente hacia el costado Tomar siempre mediciones en el mismo o do pues las lecturas de temperatura pueden diferir de un o do al otro Las lecturas tomadas mientras un ni o est durmiendo no deben compararse con las tomadas cuando est despierto Se recomienda tomar tres lecturas en el mismo o do interpretando la m s alta como la lectura en el caso de Reci n nacidos en los primeros 100 d as Ni os de menos tres a os de edad con sistemas inmunol gicos compro metidos o con condiciones donde la ausencia de fiebre resulta cr tica Un usuario nuevo de un Term metro de O do hasta establecer la t cnica adecuada Introducci n Gracias por comprar el Term metro de O do MABIS S rvase leer las siguientes instrucciones para lograr las temperaturas m s exactas posibles y un funcionamiento seguro Con el debido cuidado y uso su term metro le brindar a os de uso y lecturas confiables Su Term metro de O do ha sido dise ado para controlar la temperatura corporal humana en el hogar y es adecuado para cualquier edad Es menos peligroso que el term metro rectal m s f cil y r pido que las mediciones orales tradicionales y puede incluso utilizarse mientras el ni o duerme En un segundo se toman 512 lecturas que se convierten en una sola temperatura visualiz ndose la temperatura pico en el visor NOTA Las mediciones tomadas con un Term metro de O do son comparables con las
5. el o do pueden ser causa de lecturas inexactas Para Limpiar e Use un hisopo de alcohol o un algod n suave embebido en alcohol isopropilo al 70 para la estructura del term metro y la lente del medidor Figs 1 3 No use toallas de papel las fibras pueden rayar la lente e Aseg rese de que no entre l quido en el interior del term metro e Jam s use agentes de limpieza abrasivos solventes o gasolina para limpieza e No sumerja la unidad en agua ni en otros l quidos de limpieza Para Guardar Ee e Retire la bater a si no ha usado el term metro por un per odo de tiempo prolongado e Guarde la unidad en un lugar oscuro limpio y seco a una temperatura comprendida entre 68 F 122 F 20 C 50 C Fig 3 e Proteja el term metro de impactos o golpes severos Mant ngalo guardado en el estuche protector Fig 2 Como Tomar una Lectura NOTA Muchos pediatras recomiendan el uso de term metros de 3G gt as Orc o dos para ni os de m s de 6 meses o LF OO cas qui 1 Presione y suelte el bot n SCAN ESCANEAR Despu s de Fig 1 dos segundos el sistema realizar un auto examen Fig 1 y _ mostrar la ltima temperatura tomada con s mbolo F E an ya titilando indica que el term metro est listo para tomar la JJ y lectura de la temperatura Fig 2 Fig 2 2 Suavemente inserte el medidor del term metro en el canal auditivo hasta que
6. sienta una leve resistencia El term metro emitir un sonido beep cuando el sensor de auto posici n detecta que se ha colocado correctamente Si la unidad no emite el sonido beep suavemente vuelva a colocar el tem metro NOTA Para desactivar el sensor de auto posici n presione el bot n SCAN ESCANEAR inmediatamente despu s de insertar el term metro en el canal auditivo 3 Despu s que la unidad emite el sonido beep presione el bot n SCAN ESCANEAR Fig 3 y r pidamente suelte el bot n El dispositivo emitir una vez m s un sonido beep cuando la medici n est completa NOTA Si no presiona el bot n SCAN ESCANEAR cuando est Fig 5 colocado en el canal auditivo el term metro autom ticamente tomar una medici n en 9 segundos 4 Si la medici n est por debajo de 100 4 F 38 C el term metro emitir un sonido beep una vez y la medici n se visualizar en el visor con un simbolode cara sonriente Fig 4 5 Si la temperatura es de 100 4 F 38 C o mayor el term metro emitir un sonido beep largo seguido de dos sonidos beeps cortos La medici n estar indicada en el visor mediante un s mbolo de cara triste para indicar que hay fiebre Fig 5 6 El term metro sonar autom ticamente y se apagar despu s de aproximadamente 1 minuto si no se usa NOTE A los efectos de garantizar exactitud espere 1 Espere un m nimo de 10 segundos entre lecturas sucesivas
7. INSTRUCTION MANUAL Instant Ear Thermometer Please read this detailed guidebook completely before operating this unit DETAILED GUIDEBOOK English Spanish Limited Five Year Warranty Your Ear Thermometer is guaranteed to be free of manufacturing defects for a period of five years from the date of purchase under normal use This limited warranty does not apply to use in any clinical or commercial applications If the unit fails to operate during the warranty period return it postage prepaid along with 5 00 for return shipping and insurance to Repair Department 1931 Norman Drive South Waukegan IL 60085 When returning a product please also include a letter with your name address phone number and brief description of the specific problem Please carefully package the product to avoid any damage that may occur while in the transit Packaging insurance with returned receipt is recommended If the warrantor determines that the unit failed to operate due to a manufacturing defect the unit will be repaired or replaced at the option of the warrantor Repair or replacement of the unit is the sole remedy under this limited warranty This warranty gives you specific legal rights which vary from state to state As a condition of this warranty the enclosed warranty registration card must be completed and sent to us within 10 days of the purchase date This Limited Warranty constitutes the warrantor s only responsibility and obl
8. amos Caja Gu a de Instrucciones Gu as para un Inicio R pido una bater a tipo CR2032 Complies with US ASTM E 1965 98 Las especificaciones est n sujetas a cambio sin previo aviso 91 032 144107 8 06 2006 ReliOn 24
9. asurements taken are automatically stored into memory To recall measurements press the SCAN button to turn the unit on After the unit beeps press the M button to view measurements in Memory id memory Continue to press the M button to view the Symbol naex next previously stored measurement Fig 1 The unit will beep each time a recorded measurement is viewed Replacing the Battery Your Instant Ear Thermometer requires one lithium battery type CR2032 The battery needs to be replaced when the low battery symbol appears on the display To replace the battery 1 Slide the battery cover off 2 Using a non metal pointed tool carefully remove the battery and insert the new battery with the positive side facing up 3 Replace the battery cover NOTE Please properly dispose the battery away from small children and heat Fahrenheit Celsius Memory symbol and measurement number Scanning in progress Low battery Happy face Indicates temperature is lower than 100 4 F 38 0 C Sad face Indicates temperature is higher than 100 4 F 38 0 C Troubleshooting Display Symbol Condition Cause Corrective Action Lo Measurement is below normal temperature range Retake temperature positioning the probe snugly into the ear canal Ha Measurement is above normal temperature range Operating temperature is Retake temperature position
10. calling Measurements in Memory 0 0 000 9 Replacing the Batley ccisecac nde rre ra 9 SYMBOLS corras ar deta 10 Troubleshootnd 3 ocolocoes arteria ree 11 Product Specifications cui id a 12 e For infants it is best to position infant flat with the ear facing upwards e For children and adults it is best to stand behind and slightly to the side e Always take measurements in the same ear since temperature readings may differ from ear to ear e Readings taken while a child is sleeping should not be compared to readings taken while awake e It is recommended to take three readings in the same ear with the highest interpreted as the reading for newborn infants in the first 100 days children under three years of age with comprised immune systems or with conditions where the absence of fever is critical anew user of an Instant Ear Thermometer until proper technique is established Introduction Thank you for purchasing an Instant Ear Thermometer Please read the follow ing instructions to achieve the most accurate temperatures and safe operation With proper care and use your thermometer will provide you with many years of reliable readings Your Instant Ear Thermometer is intended for monitoring human body temperature in the home and is appropriate for all ages It is less threatening than a rectal thermometer is easier and faster than standard oral measurements and can even be used while a child is s
11. de la bater a agotada de modo que quede lejos de los ni os y del calor Fahrenheit Celsius Simbolo de memoria y numero de medici n Escaneo en progreso Poca bater a Cara sonriente Indica que la temperatura es inferior a 100 4 F 38 0 C Cara triste Indica que la temperatura es superior a 100 4 F 38 0 C Soluci n de Problems S mbolo Condici n Causa Acci n Correctiva 0 Medici n inferior al rango Vuelva a tomar la temperatura Lu normal de temperatura colocando el sensor c modamente en el canal auditivo Medici n superior al rango normal de temperatura Vuelva a tomar la temperatura colocando el sensor c modamente en el canal auditivo La temperatura operativa se encuentra fuera de rango permitido 60 8 F 104 0 F 16 0 C 40 0 C Lleve el term metro a una habitaci n donde la temperatura est dentro de un rango permitido Espere 45 minutos para establizar el term metro Vuelva a tomar la temperatura colocando el sensor c modamente en el canal auditivo Visor en blanco Controle la polaridad o tensi n de la bater a Es probable que tenga que cambiar a Poca bater a Cambie la bater a de LO inmediato Advertencia de poca bateria La unidad funcionara igualmente cambie la bateria co cuando sea posible Especificaciones del Producto Nombre y n mero de modelo Sistema de v
12. er into the ear canal 3 After the unit beeps press the SCAN button Fig 3 and promptly release the button The device will beep once again after the measurement is complete NOTE If you do NOT press the SCAN button once it is placed in the ear canal the thermometer will automatically take a measurement in 9 seconds 4 If the measurement is below 100 4 F 38 C the thermometer will beep once and the measurement will be shown on the display with a happy face symbol Fig 4 5588 0 eS qui Fig 1 S 085 Fig 2 Fig 3 G BS Fig 4 a We 3 Fig 5 5 If the temperature is 100 4 F 38 C or above the thermometer will sound one long beep followed by two short beeps The measurement will be shown on the display with a sad face symbol to indicate fever Fig 5 6 Thermometer will automatically beep and shut off after approximately 1 minute of non use NOTE To ensure accuracy 1 Please wait at least 10 seconds between successive readings 2 Clean the probe lens before and after each use Changing Modes Temperature readings can be displayed in either Fahrenheit ki on 5 or Celsius To switch between F or C press and hold the A F SCAN button Without releasing also press the M button and toggle between the modes Fig 1 and 2 Fig 1 Fig 2 Recalling Measurements in Memory B3 100 5 Fig 1 The last 10 me
13. igation to repair and or replace materials or components We make no other express or implied warranties arising by operation of law or otherwise or any warranty of merchantability orfitness for a particular use or purpose whether or not the use or purpose has been disclosed to the warrantor in specifications drawings or otherwise and whether or not the warrantor s products are specifically designed and or manufactured by the warrantor for the buyer s use or purposes except for the limited warranty stated above The warrantor will not be responsible for any indirect incidental special consequential or punitive damages or other loss including but not limited to damage to or loss of other property or equipment and personal injuries whether to purchaser or others The warrantor shall in no event be liable to the purchaser for any amount in excess of the cost of repair and or replacement of the unit Manufactured for MABIS Healthcare 1931 Norman Drive South Waukegan IL 60085 USA www mabis net TOLL FREE CUSTOMER CARE HELPLINE E mail productinfo mabis net 1 800 622 4714 Phone 847 680 6811 2 Fax 847 680 9646 Helpful RIMS ca A OEA 3 MOGUCOM scaner rra 4 Product FoatUrES aida as 5 Nite Glo DISPIAY cacaos is A 5 General Care amp Important Information 6 Cleaning amp Storage comics das T Takinga Reading surcar eg ei Sete tenons A 8 Changing MOd6S zsrsr innser an aa ed a sees 9 Re
14. ing the probe snugly into the ear canal Take thermometer to a room E rr outside of the permissible where the temperature is range 60 8 F 104 0 F within the permissible range 16 0 C 40 0 C Wait 45 minutes to stabilize thermometer Retake temperature positioning the probe snugly into the ear canal Blank display Check battery polarity or voltage May need to replace battery Low battery Replace battery immediately cs Low battery warning Unit will work however LO replace battery when possible cas Product Specifications Name and model number Display system Accuracy Measuring range Memory Tone Operating temperature Storage temperature Automatic power off Battery Dimensions Weight Accessories Standards Specifications are subject to change without notice Instant Ear Thermometer 144 107 000 Liquid Crystal Display with 0 1 F 0 1 C resolution 0 4 F 96 8 F 102 2 F 0 2 C 36 0 C 39 C 0 5 F lt 96 8 F or gt 102 2 F 0 3 C lt 36 0 C or gt 39 C 93 2 F 109 4 F 34 0 C 43 0 C Automatically stores up to 10 readings One short beep sounds when the unit is turned ON After the measurement is complete one beep sounds for temperatures under 100 4 F 38 0 C One long beep followed by two short beeps sound for temperatures over 100 4 F 38 0 C One short beep sounds for temperatures lt 93 2 F
15. isualizaci n Exactitud Extensi n de temperatura Memoria Tono Temperatura operativa Temperatura de almacenamiento Apagado autom tico Bater a Dimensiones Peso Accesorios Normas Term metro de O do 144 107 000 Visor de l quido con resoluci n de 0 1 F 0 1 C 0 4 F 96 8 F 102 2 F 0 2 C 36 0 C 39 C 0 5 F lt 96 8 F 0 gt 102 2 F 0 3 C lt 36 0 C 0 gt 39 C 93 2 F 109 4 F 34 0 C 43 0 C Almacena automaticamente un maximo de 10 lecturas Se escucha un sonido beep corto cuando se enciende la unidad ON Una vez terminada la medici n se escucha un sonido beep para temperaturas inferiores a 100 4 F 38 0 C En el caso de temperaturas superiores a 100 4 F 38 0 C se escucha un sonido beep largo seguido de dos sonidos beep cortos Para temperaturas lt 93 2 F 34 C Bajas o gt 109 4 F 43 C Altas se escucha un sonido beep corto El term metro emite un sonido beep una vez para cada invocaci n de memoria y cuando la unidad se apaga autom ticamente Los sonidos beep cortos r pidos y continuos indican que queda poca bater a 60 8 F a 104 0 F 16 0 C a 40 0 C a la humedad relativa del aire no condens ndose de hasta 95 4 0 F a 122 0 F 20 0 C a 50 0 C Apagado automatico despu s de aproximadamente 1 minuto de falta de uso 1 tipo CR2032 4 1 2 L x 1 3 8 W x 1 H 11 5cm x 3 5cm x 2 5cm Con la bater a 1 6 onzas 45 gr
16. lecturas orales Fuciones de Producto Medidor Lente de medidor Bot n de SCAN Bot n de M Memoria Visor de LCD Cubierta de la bateria Exhibici n de Nite Glo Su term metro instante para el o do ofrece una exhibici n digital La exhibi ci n es iluminara aproximadamente 5 segundos cada ves que el bot n de SCAN es presionado para tomar la medida Despu s de que cada medida este completa la exhibici n permanecer iluminda aproximadamente 5 segundos La exhibici n tambi n iluminara por aproximadamente 5 segundos cada ves Cuidado General e Informacion Importante Su Term metro de O do mide el calor irradiado desde el t mpano y el tejido circundante Esta energ a se transfiere a trav s del medidor y se convierte en un valor nico de temperatura Si bien las lecturas tomadas del t mpano membrana ofrecen las lecturas m s precisas si se emplea una t cnica inadecuada se pueden generar lecturas inferiores lo que resultar en un diagn stico err neo de fiebre 1 selo solamente bajo la supervisi n de un adulto 2 La cera en el canal auditivo puede dar como resultado una lectura inexacta Consulte con su profesional de salud acerca de los procedimientos adecuados para quitar la cera y limpiar el o do No haga demasiada fuerza para insertar el sensor en la oreja No use si el canal auditivo est h medo o si hay infecci n Las mediciones en el o do son comparables a las orales
17. leeping In one second 512 readings are taken These readings are converted into a single temperature with the peak temperature displayed on the screen NOTE Measurements taken with an Instant Ear Thermometer are comparable to oral readings Product Features Probe Probe lens SCAN button M button Memory LCD display Battery cover Nite Glo Display Your Instant Ear Thermometer features an illuminating digital display The display will illuminate for approximately 5 seconds every time the SCAN button is pressed to take a measurement After each measurement is complete the display will remain illuminated for approximately 5 seconds The display will also illuminate for approximately 5 seconds every time the M button is pressed to recall a reading in memory General Care amp Important Information Your Instant Ear Thermometer measures the heat radiated from the eardrum and the surrounding tissue This energy is transferred through the probe and converted into a single temperature value Although readings taken from the eardrum tympanic membrane can provide the most accurate readings improp er technique can generate lower readings resulting in a misdiagnosed fever 1 The thermometer should only be used under the supervision of an adult 2 Earwax in ear canal may cause an inaccurate reading Consult your healthcare professional for proper removal and ear cleaning procedures 3 Do n
18. ntal especial emergente o punitorio u otra p rdida incluido aunque no limitado a da o o p rdida de otros bienes o equipos y lesiones personales al comprador o a terceros Bajo ning n concepto ser tenida el proteger como responsable ante el comprador por cualquier monto en exceso del costo de reparaci n y o reemplazo de la unidad Fabricado por MABIS Healthcare 1931 Norman Drive South Waukegan IL 60085 USA www mabis net L NEA PARA LLAMADAS CON PAGO E mail productinfo mabis net REVERTIDO DE AYUDA DE CUIDADOS Phone 847 680 6811 PARA CLIENTES 1 800 622 4714 Fax 847 680 9646 O Surgerencias Utiles ocoocooocmomcerrnnnnmno 15 IMITOQUECI N arroces 16 Funciones del ProduGle soene io ic il a 17 Exhibici n de Nite Glo 1 0 2 2 0 cee eee eee eee ee 17 Cuidado General e Informaci n Importante 18 Limpieza y Almacenamiento o oooocccoccocnon 19 C mo Tomar una Medici n n seo eck eee ee 20 C mo Cambiar los Modos casks ciedcdeneceeeeeewannawe nd 21 C mo Invocar a las Mediciones en la Memoria 21 C mo Cambiar la Baena cae ci ewer ene eee ra 21 SIMDOOS cornada tanda din 22 Soluci n de Problems occas webs at 23 Especificaciones del Producto oocccococccco 24 Sugerencias Utiles En el caso de ni os peque os es mejor colocar al ni o acostado con el o do hacia arriba En el caso de ni os m s grandes y adultos es mejor pararse
19. ombre direccion numero de tel fono y una breve descripci n del problema especifico Empaquete por favor cuidadosamente el producto para evitar cualquier da o que pueda ocurrir mientras en transito Se recomienda aseguro para el paquete con el recibo vuelto Si el proteger determina que la falla de la unidad se debi a un defecto de fabricaci n ser reparada o reemplazada a opci n del proteger La reparaci n o el reemplazo de la unidad es el nico recurso conforme a esta garant a limitada que le otorga derecho legales espec ficos que var an seg n el estado Como condici n de esta garant a deber completar y enviarnos la ficha de registro de garant a que se remite adjunto dentro de los 10 d as de la fecha de compra Esta Garant a Limitada constituye la nica responsabilidad y obligaci n del proteger para la reparaci n y o el reemplazo de materiales o componentes No otorgamos ninguna otra garant a expresa o impl cita por ministerio de la ley o de otro modo ni ninguna garant a de comerciabilidad o uso adecuado para un uso o prop sito en particular hubiera o no sido dicho uso o prop sito revelado al proteger en especificaciones planos o de otro modo y hubiera n o no sido los productos del proteger espec ficamente dise ados y o fabricados por sta para el uso o prop sito del comprador con excepci n de la garant a limitada antes mencionada El proteger no ser tenida como responsable por todo da o indirecto incide
20. ot use excessive force to insert probe into ear 4 Do not use if ear canal is wet or if infection is present 5 Ear measurements are comparable to oral measurements Remember temperatures can vary from 97 0 F to 99 0 F 36 1 C to 37 2 C and still may be considered normal Time of day level of activity exercise and other activities can attribute to variations in temperature However unlike oral temperatures factors such as smoking talking and drinking do not affect ear measurements Do not walk run or talk during temperature taking Clean the probe tip before and after each use Store the unit in the protective case when not in use Do not touch the probe with fingers 0 Do not store the unit where it will be exposed to direct sunlight dust or humidity Avoid extreme temperatures 11 Dropping or subjecting your thermometer to strong shocks should be avoided 12 Do not attempt to disassemble the unit except to replace the battery 13 If measurement is not attainable the unit must be replaced SP PND NOTE Performance of the device may be degraded if operated outside of stated temperature and humidity range stored outside of stated temperature and humidity range thermometer undergoes mechanical shock drop patient temperature is below ambient temperature Cleaning and Storage To ensure accurate measurements clean the probe lens before and after each use Fingerprints and earwax can cause inaccurate
21. readings To Clean e Use an alcohol swab or a soft cotton swab moistened with alcohol 70 Isopropyl to the thermometer casing and probe lens Figs 1 3 Do not use paper towels The fibers may scratch the lens Make sure that liquid does not enter the interior of the thermometer Never use abrasive cleaning agents thinners or gasoline for cleaning Do not immerse into water or other cleaning liquids To Store Remove the battery if the thermometer will not be OO used for an extended period of time e Store in a sun free and dust free dry area ata temperature between 68 F 122 F 20 C 50 C e Protect the thermometer from severe impact or shock Keep stored in the protective storage case Fig 3 Taking a Reading NOTE Many pediatricians recommend the use of ear thermometers for children older than 6 months 1 Press and release the SCAN button After two seconds the system will perform a self test Fig 1 and show the last temperature taken along with a flashing F to indicate the unit is ready for measurement Fig 2 2 Gently insert the probe snugly into the ear canal until a slight resistance is felt The thermometer will beep when the auto position sensor detects proper placement If the unit does NOT beep gently reposition the thermometer NOTE To disable the auto position sensor immediately press the SCAN button after inserting the thermomet
Download Pdf Manuals
Related Search
Related Contents
THE INSTITUTE OF COMPANY SECRETARIES OF INDIA Installation Guide - University of Kent Motorsense Kosa motorowa Foice a motor AERO-868 AC IT UniPlotter User Manual タンデムバックレスト 組付・取扱説明書 LES DICTIONNAIRES - Association Française pour la Lecture USER`S MANUAL Samsung 400UXN Manual de Usuario Copyright © All rights reserved.