Home

Philips 21PT522A CRT Television User Manual

image

Contents

1. 11 4 Data Selection scout e 12 5 Mounting the FT85011A Transmitter FR85011A Receiver Using the Wall Clip 15 6 FT85011A Transmitter FR85011A Receiver Connections 16 7 95 232 Data Communication Wiring 18 8 5 422 Data Communication Wiring 19 9 RS 852 Wire Half Duplex Data Communication Wiring 20 10 RS 485 4 Wire Full Duplex Data Communication 21 11 Manchester Data Communication Wiring 22 12 Bi Phase Data Communication Wiring eee eee 23 List Tables Data Communication Switch Settings 13 B Data Connector Pin Assignments 17 C Troubleshooting with Front Panel Indicators 24 C2604M 7 06 3 Important Safety Instructions So m ee Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions 0 not install near any heat sources such as radiators heat registers stoves or other pparatus including amplifiers that produce heat Do not defeat
2. RECEIVER DEVICE CONNECTOR 1 RS 232 2 SELECTION 3 0 5 RX DATA IN 6 TX DATA OUT 7 8 GND RS 232 DATA CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FT85011A TRANSMITTER DEVICE B DATA CONNECTOR 1 RS 232 2 DATA SELECTION RS 232 3 RX 4 0 TX 5 RX DATA IN GND 6 TX DATA OUT 7 8 GND RS 232 DATA CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER Figure 7 RS 232 Data Communication Wiring C2604M 7 06 C2604M 7 06 FR85011A RECEIVER DEVICEA pg pg CONNECTOR 1 TX DATA 0013 RS 422 2 TX DATA OUT DATA SELECTION 3 RX DATA IN 4 RX DATA IN 1 RS 422 DATA CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FT85011A TRANSMITTER DEVICE B 8 422 1 TX DATA OUT RS 422 2 TX DATA OUT DATA SELECTION 3 RX DATA IN 4 RX DATA IN c 5 422 DATA CONNECTIONS BETWEEN DEVICE AND FT85011A TRANSMITTER Figure 8 RS 422 Data Communication Wiring 20 FR85011A RECEIVER CONNECTOR RS 485 1 THR DATA OUT DATA IN RS 485 2 WIRE 2 TJR DATA OUT DATA IN DATA SELECTION 3 2 4 5 6 7 8 GND RS 485 2 WIRE DATA CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIV
3. Figure 6 FT85011A Transmitter FR85011A Receiver Connections C2604M 7 06 Table Data Connector Pin Assignments Pin RS 485 RS 485 Number RS 232 RS 422 2 Wire 4 Wire Manchester Bi Phase 1 Out T R Qut In TX Out 2 TX Qut T R Out In TX 3 RX In RX In RX Ine W RX In 4 RX In RX In RX In RX In 5 RX In 6 TX Out m 7 Out W Out 8 TX Qut B TX Out 9 Ground Shield Shield NOTES Ground may be required based on conditions of insta EIA TIA 422 and EIA TIA 485 standards for additional information lation Refer to the current version 01 RX In Ine RX In 104 and R In denote data input to the transmitter receiver TX Out TX TX Qut T Qut and T Out denote data output from the ransmitter receiver Wdenotes white wire and B denotes black wire Data ports are not terminated For RS 422 RS 485 2 wire RS 485 4 wire Manchester and Bi Phase data signals termination may be required based on conditions of installation f termination is required terminate the data signal at the endpoint of the data bus using a 120 ohm resistor C2604M 7 06 FR85011A
4. MANCHESTER DATA CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER W DENOTES WHITE WIRE AND B DENOTES BLACK WIRE Figure 11 Manchester Data Communication Wiring C2604M 7 06 C2604M 7 06 FR85011A RECEIVER DATA CONNECTOR DEVICE A 1 BI PHASE BIENE 2 DATA SELECTION 3 RX DATA IN 4 4 RX DATA IN 5 6 7 8 SHIELD GND BI PHASE DATA CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FT85011A TRANSMITTER DEVICE B DATA CONNECTOR 1 BI PHASE BI PHASE DATA SELECTION 4 Wh 7 DATA OUT 8 TX DATA OUT GND TT M V BI PHASE DATA CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER Figure 12 Bi Phase Data Communication Wiring 23 Troubleshooting LED indicators on the front panel of the FT85011A transmitter FR85011A receiver refer to Figure 2 allow you to monitor signal status laser status data activity and operating power Table C provides information about the front panel indicators and associated troubleshooting guidelines Table C Troubleshooting with Front Panel Indicators Indicator Color Possible Cause Corrective Action Power LED Pelco badge Blue Pelco logo lights Blue Pelco logo does not light Power is being applied to the module Power is not being applied to the module Power connection is faulty No action required Check powe
5. lt lt FLANGE La vERTICAL MOUNTING HOLE 2 Q4 HORIZONTAL MOUNTING HOLE 2 TRANSMITTER RECEIVER 4 LOWER SCREW PHILLIPS gt WALL CLIP FLANGE PAN HEAD WITH LOCK WASHER 2 1 Figure 5 Mounting the FT85011A Transmitter FR85011A Receiver Using the Wall Clip C2604M 7 06 15 CONNECTIONS Connections to the FT85011A transmitter and the FR85011A receiver are made on the rear panel of the modules and consist of the following Power connection NOTES A12 VDC or 24 VAC power supply can be used to power the transmitter receiver when used as a stand alone module A 12 VDC power supply is provided If a 24 VAC power supply is used the power supply must be a Listed Direct Plug In Power Unit marked as Class 2 and rated as 24 VAC 300 mA minimum output n extreme temperature conditions it is recommended that an industrial rated outdoor power supply such as the Pelco WCS1 4 power supply be used Fiber connection Data connection Video input connection transmitter only Video output connection receiver only Figure 6 provides an illustration of FT85011A transmitter FR850114 receiver connections POWER ALARM CONNECTION FOR RACK MOUNTED MODULE POWER CONNECTION FOR STAND ALONE MODULE FIBER OPTIC CABLE DATA COMMUNICATION CABLE REFER TO TABLE B FOR DATA CONNECTOR PIN ASSIGNMENTS AND TO FIGURES 7 12 FOR WIRING DIAGRAMS COAXIAL CABLE
6. Installation PACKAGE CONTENTS The following items are supplied 1 FT85011A transmitter or FR85011A receiver 1 Regulated switching power supply with four plug adapters North American Australian U K and European configurations 100 240 VAC 50 60 Hz input 12 VDC output 1 Wall clip with two 4 40 x 0 250 inch Phillips pan head screws with lock washers for attach ment of single module to wall 1 FT85011A FR85011A Fiber Transmitter and Receiver Installation manual this manual DATA COMMUNICATION SETUP NOTE Asa matter of convenience it is recommended that you set the desired data communication before mounting the FT85011A transmitter FR85011A receiver into a rack or onto a wall The Data Selection switch which is located on the rear panel of the FT85011A transmitter FR85011A receiver is a 10 position rotary switch that allows you to set the data communication required for the transfer of data refer to Figure 4 DATA SELECTION SWITCH Figure 4 Data Selection Switch 12 C2604M 7 06 With the FT85011A transmitter FR85011A receiver powered off the Data Selection switch to the required data communication using a small screwdriver Refer to Table A for data communication switch setti Note the fol e TheFT85011A transmitter FR85011A receiver allows data translation between RS 232 and ngs Table A Data Communication Switch Settings Data Communication
7. Switch Setting RS 232 RS 422 0 default setting 1 RS 485 2 Wire RS 485 4 Wire Manchester Bi Phase Coaxitron ony wy N NOTE Switch positions 6 9 are not used owing RS 422 signal levels Consequently the Data Selection switch can be set to 0 RS 232 on the transm to 1 RS 422 on the transmitter and to 0 RS 232 on the receiver e If you wish to change the data communication setting after the FT85011A transmitter 1A receiver has been powered on power off the transmitter receiver change the data communication setting and then power on the transmitter receiver again FR850 C2604M 7 06 itter and to 1 RS 422 on the receiver Conversely the Data Selection switch can be set MOUNTING The FT85011A transmitter FR85011A receiver can be mounted into a rack or can be used as a stan d alone module As a stand alone module the unit can be placed on a desktop or can be mounted to a wall NOTE As a matter of convenience it is recommended that you set the desired data communication before mounting the FT85011A transmitter FR85011A receiver To set the desired data communication refer to the Data Communication Setup section MOUNTING THE TRANSMITTER RECEIVER INTO A RACK The FT85011A transmitter FR85011A receiver can be installed into an RK5000 Series rack mount chassis which can be mounted into an industry standard 19 inch 48 26 cm equipment rack The RK5000 Series r
8. No action required being received and laser is operating properly Red The optical signal is Remote fiber module is not Check power connections not being received powered on Replace power supply if necessary Fiber optic cable is not Check fiber optic connected connections Fiber optic cable connectors Clean polish or replace fiber are dirty or are damaged optic cable connectors as necessary Fiber optic cable is Replace cable defective Optical dB losses in the Check for problems with the iber optic installation fiber optic installation for exceed the optical power example excessive dB budget specification stated losses in connectors splices in the Specifications patch panels cables section and so on Optical dB losses in the Contact Product Support iber optic installation meet he optical power budget specification stated in the Specifications section however a fiber module is defective Flashing red Laser has shut down Fiber module is operating in Ensure that fiber module C2604M 7 06 extreme environmental conditions for example operating temperature is below or above recom mended range as stated in the Specifications section operates according to operating conditions stated in the Specifications section and then cycle the power If problem persists contact Product Support Laser has reached end of life Cycle the power If problem persists contact Product S
9. a 5 dB buffer for ice losses coated models replace the first letter Fin coated version of FT85011AMSTR for example is CT85011AMSTR h higher optical power budgets contact the factory Model No Optical Maximum Laser FT85011A Compatible Power Transmission Class 1 Transmitter Receivers Wavelength Budget Distance Limit Multimode 62 5 125 pm FT85011AMSTR FR85011AMSTR 1310 nm video 26dB 6km 3 7 lt 15 6mW 850 nm data 26dB 6 3 7 0 78mW FR85011MSTR 1310 nm video 204 6 3 7 15 6 mW 850 data 2048 6 3 7 0 78 mW Single Mode 9 125 FT85011ASSTR FR85011ASSTR 1310 video 2848 46 28 6 15 6 mW 1550 nm data 2848 46 km 28 6 10 0 mW FR85011SSTR 1310 nm video 20dB 30 18 6 mi 156 mW 1550 nm data 20dB 30km 18 6 10 0 mW FT85011ASFCR FR85011ASFCR 1310 nm video 2848 46 28 6 15 6 mW 1550 nm data 28dB 46km 28 6 mi 10 0 mW FR85011SFCR 1310 nm video 2048 30 18 6 mi 156 mW 1550 nm data 20dB 30 km 18 6 10 0 mW The FT85011A transmitter and compatible receivers are classified by the FDA as Class 1 laser products When using 50 125 um multimode fiber subtract 3 dB from the optical power budget he model number with the letter C C2604M 7 06 OPTICAL POWER BUDGET TRANSMISSION DISTANCE AND LASE
10. com 1509001 United States Canada United Kingdom The Netherlands Spain Scandinavia France Middle East
11. 0 Series LCD monitors Two years on standard motorized or fixed focal length lenses Two years on Legacy CM6700 CM6800 CM9700 Series matrix and DF5 DF8 Series fixed dome products Two years on Spectra Esprit ExSite and PS20 scanners including when used in continuous motion applications e Two years on Esprit and WW5700 Series window wiper excluding wiper blades Two years except lamp and color wheel on Digital Light Processing DLP displays The lamp and color wheel will be covered for a period of 90 days The air filter is not covered under warranty Eighteen months on DX Series digital video recorders NVR300 Series network video recorders and Endura Series distributed network based video products e year except video heads on video cassette recorders VCRs Video heads will be covered for a period of six months e Six months on all pan and tilts scanners or preset lenses used in continuous motion applications that is preset scan tour and auto scan modes Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment All goods requiring warranty repair shall be sent freight prepaid to Pelco Clovis California Repairs made necessary by reason of misuse alteration normal wear or accident are not covered under this warranty Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of t
12. 11A TRANSMITTER RECEIVER Figure 2 Front Panel of FT85011A Transmitter and FR85011A Receiver DATA TX LED DATA RX LED VIDEO PRESENT LED OPTIC FAULT LED optical signal status laser status indicator POWER LED Pelco badge 00000 For detailed information about the front panel indicators refer to the Troubleshooting section 10 C2604M 7 06 REAR PANEL All connections to the FT85011A transmitter and the FR85011A receiver are made to the rear panel of the modules refer to Figure 3 m sh VI VI eoo oo 8 FT85011A FR85011A TRANSMITTER RECEIVER Figure 3 Rear Panel of FT85011A Transmitter and FR85011A Receiver RACK POWER ALARM CONNECTOR 4 pin connector for power alarm connection of rack mounted module STAND ALONE POWER CONNECTOR 2 pin connector for power connection of stand alone module removable mating connector with screw terminals not shown IBER OPTIC CONNECTOR ST or FC dependent on FT85011A FR85011A model DATA CONNECTOR 9 pin connector removable mating connector with screw terminals not own DATA SELECTION SWITCH 10 position rotary switch DEO IN CONNECTOR 75 ohm BNC analog video input transmitter only DEO OUT CONNECTOR 75 ohm BNC analog video output receiver only For addi ional information about rear panel connections and about the Data Selection switch refer to the nstallation section C2604M 7 06
13. ER FT85011A TRANSMITTER RS 485 DATA CONNECTOR DEVICEB 2 WIRE 1 THR DATA OUT DATA IN RS 485 2 WIRE 2 T R DATA OUT DATA IN DATA SELECTION 3 2 4 5 6 7 8 GND RS 485 2 WIRE DATA CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER Figure 9 RS 485 2 Wire Half Duplex Data Communication Wiring C2604M 7 06 FR85011A RECEIVER CONNECTOR DATA OUT RS 485 4 WIRE TX DATA OUT DATA SELECTION RX DATA IN 3 RX DATA IN RS 485 4 WIRE DATA CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FT85011A TRANSMITTER DATA CONNECTOR TX DATA OUT RS 485 4 WIRE TX DATA OUT DATA SELECTION RX DATA IN 3 RX DATA IN RS 485 4 WIRE DATA CONNECTIONS BETWEEN DEVICE B AND FT85011A TRANSMITTER Figure 10 RS 485 4 Wire Full Duplex Data Communication Wiring C2604M 7 06 21 22 FR85011A DEVICE A DATA CONNECTOR 1 MANCHESTER MANCHES TER 2 DATA SELECTION 3 DATA 4 4 RX DATA IN 5 6 SHIELD 7 8 GND MANCHESTER DATA CONNECTIONS BETWEEN DEVICE A AND FR85011A RECEIVER FT85011A TRANSMITTER DEVICE B DATA CONNECTOR 1 MANCHESTER DATA SELECTION 4 MANCHESTER Cc 7 0014 8 TX DATA OUT GND
14. INSTALLATION FT85011A FR85011A Fiber Transmitter and Receiver Single Channel Digitally Encoded Video with Bidirectional Data C2604M 7 06 Contents Important Safety Instructions 4 Regulatory NOtICES sorser er ander ETENEE E 6 Product OVENI We Risk esee PE RI Ed Yeu dep PES 7 Description 1 7 17016 cs odesva ECL UU ACH ERREUR UNE A MEM 9 Optional 188 9 Front Panel T 10 hear Panels UA GARE EDD udis 11 12 Package Contents 12 Data Communication Setup 12 14 Mounting the Transmitter Receiver into a 14 Mounting the Transmitter Receiver to a Wall 14 EET 16 Troubleshooting re 24 OPSCINIGATONG 2 List of Illustrations 1 FT85011A Transmitter and FR85011A Receiver Single Channel Video and 5 Y ke eR ROI 7 2 Front Panel of FT85011A Transmitter and FR85011A Receiver 10 3 Rear Panel of FT85011A Transmitter and FR85011A
15. Maximum transmission distance is limited by fiber bandwidth Maximum transmission distance is based on attenuation of 0 5 dB km plus a 5 dB buffer for connector and splice losses NOTES e For conformal coated models of rack mountable transmitters and receivers replace the first letter Fin the model number with the letter C The conformal coated version of FR85011AMSTR for example is CR85011AMSTR For models with higher optical power budgets contact the factory C2604M 7 06 29 30 gt lt This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002 96 EC of the European Union regarding the disposal of waste electrical and electronic equipment WEEE Contact your local dealer for procedures for recycling this equipment 2604 7 06 PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace without charge any merchandise proved defective in material or workmanship for a period of one year after the date of shipment Exceptions to this warranty are as noted below Five years on FR FT FS Series fiber optic products Three years on Genex Series products multiplexers server and keyboard Three years on Camclosure and fixed camera models except the CC3701H 2 CC3701H 2X CC3751H 2 CC3651H 2X MC3651H 2 and MC3651H 2X camera models which have a five year warranty Three years on PMCL200 300 40
16. NAL DATA APPLICATION ONE ONE VIDEO VIDEO INPUT OUTPUT 85011 FR85011A PO TRANSMITTER TE RECEIVER PLE COAXITRON FIBER COAXITRON DATA DATA SINGLE CHANNEL VIDEO AND COAXITRON DATA APPLICATION Figure 1 FT85011A Transmitter and FR85011A Receiver Single Channel Video and Data Applications Features of the FT85011A FR85011A fiber optic transmission system include the following e O bit digitally encoded video for high quality video transmission over a single fiber e Bidirectional data channel that supports RS 232 RS 422 RS 485 2 wire 4 wire Manchester Bi Phase and Coaxitron communication e Patent pending transmission technology allowing for Coaxitron control at full distance capabilities e Integrated wavelength division multiplexing WDM allowing video and data channels to be transmitted in the same fiber using different wavelengths e Multimode fiber support for distances up to 6 km e Single mode fiber support for distances up to 46 km Exceeds all requirements for the RS 250C Medium Haul Transmission specification Compatible with NTSC PAL and SECAM video standards 2604 7 06 7 Meets NEMA TS 2 and Caltrans traffic signal control equipment standards for ambient operating temperature mechanical shock and vibration humidity with condensation high line low line voltage conditions and transient voltage protection NOTE Conformal coating is required for operation in en
17. R CLASS 1 LIMIT FR85011A RECEIVER AND COMPATIBLE TRANSMITTERS Model No Optical Maximum Laser FR85011A Compatible Power Transmission Class 1 Receiver Transmitters Wavelength Budget Distance Limit Multimode 62 5 125 FR85011AMSTR FT85011AMSTR 1310 nm video 26dB 6km 3 7 156m 850 nm data 26dB 6km 3 7 078m FT85011MSTR 1310 nm video 20dB 6km 3 7 mi 156m 585011 5 data 2048 6km 37 078 Single Mode 9 125 FR85011ASSTR FT85011ASSTR 1310 video 2848 46 km 28 6 mi 156m 1550 nm data 28 d 46 km 28 6 mi 10 0 T85011SSTR 1310 nm video 2048 30km 18 6 mif 15 6 VI 585011557 1550 nm data 2048 30km 188 mif lt 10 0 1550 284 46 km 28 6 10 0 FT85011SFCR 1310 nm video 20d 30 km 18 6 15 6 B m B m B m FR85011ASFCR FT85011ASFCR 1310 video 2848 46 28 6 lt 15 6 FS85011SFC 1550nm data 2048 30km 188 mij 10 0 The FR85011A receiver and compatible transmitters are classified by the FDA as Class 1 laser products When using 50 125 um multimode fiber subtract 3 dB from the optical power budget
18. TR Single channel fiber optic video transmitter data transceiver single mode ST connector FR85011ASSTR Single channel fiber optic video receiver data transceiver single mode ST connector FT85011ASFCR Single channel fiber optic video transmitter data transceiver single mode FC connector FR85011ASFCR Single channel fiber optic video receiver data transceiver single mode FC connector For conformal coated models replace the first letter F in the model number with the letter C The conformal coated version of FT85011AMSTR for example is CT85011AMSTR OPTIONAL ACCESSORIES The following optional accessories are available WM5001 3U Wall mount base kit for single width module WM5001 3UEXP Wall mount expansion kit for single width module RK5000 3U 19 inch rack mount chassis for 14 slots no power 3 RUs RK5000PS 3U 19 inch rack mount chassis for 12 slots with power 3 RUs EPS5000 120 External rack power supply 1 RU dual 120 W power outputs RK5001B 3U Blank filler panel single width RK5002B 3U Blank filler panel double width RK5001 1UEXP Adapter kit that allows a 3 RU single width fiber module to be used in RK5000PS 5U rack mount chassis C2604M 7 06 FRONT PANEL The front panel ofthe FT85011Atransmitter and the FR85011A receiver provides LED indicators that allowyouto monitor data activity Signal status laser status operating power referto Figure 2 FT85011A FR850
19. ack mount chassis includes the following models RK5000PS 3U and RK5000 3U Designed to accommodate fiber optic modules as follows RK5000PS 3U rack mount chassis provides 12 module slots and a power supply RK5000 3U rack mount chassis provides 14 module slots a power supply is not included Power to the modules can be supplied using the optional external power supply EPS5000 120 For additional information refer to the RK5000PS 3U RK5000 3U Fiber Rack Mount Chassis Installation manual RK5000PS 5U Designed to accommodate Endura modules but can also accommodate fiber optic modules with the use of the appropriate adapter kit The RK5001 1UEXP adapter kit is required for installation of the FT85011A transmitter FR85011A receiver into the RK5000PS 5U chassis For information about the RK5000PS 5U chassis refer to the RK5000PS 5U Rack Mount Chassis Installation manual MOUNTING THE TRANSMITTER RECEIVER TO A WALL The FT85011A transmitter FR85011A receiver can be mounted to a wall in the following ways Using the supplied wall clip for attachment of a single module to a wall For installation instructions refer to the Mounting the Transmitter Receiver Using the Wall Clip section e Using the optional WM5001 wall mount kits which are designed for mounting of single width fiber optic modules The WM5001 3U base kit allows mounting of a single module to a wall The WM5001 3UEXP expansion kit allows m
20. ation Type Video Input FT85011A Video Output FR85011A Bandwidth Gain Differential Gain Differential Phase Tilt Signal to Noise Ratio DATA Number of Channels Data Communication Maximum Baud Rate GENERAL Operating Temperature Input Power Requirements LED Indicators Dimensions Unit Weight MECHANICAL Connectors Video Rack Power Alarm Stand Alone Power Data Fiber Optic C2604M 7 06 1 Pulse code modulation 8 bit resolution 1 0 Vp p 75 ohms NTSC PAL and SECAM 6 5 MHz Unity lt 2 19 196 60 dB CCIR weighted 1 RS 232 RS 422 RS 485 2 wire 4 wire Manchester Bi Phase Coaxitron 500 kbps 40 to 167 F 40 to 75 C 12 VDC or 24 VAC 300 mA Power Video Present Optic Fault Data Tx Data Rx 8 75 Dx 1 08 W x 4 81 H 22 23 x 2 14 x 12 22 cm 148 Ib 0 67 kg BNC 4 pin connector 2 pin connector screw terminal 9 pin connector screw terminal ST for multimode fiber ST or FC for single mode fiber 21 28 OPTICAL POWER BUDGET TRANSMISSION DISTANCE AND LASER CLASS 1 LIMIT FT85011A TRANSMITTER AND COMPATIBLE RECEIVERS Maximum transm Maximum transm connector and sp NOTES e For conformal The conforma e For models wi ission distance is limited by fiber bandwidth ission distance is based on attenuation of 0 5 dB km plus
21. d conform to all local codes Use only installation methods and materials capable of supporting four times the maximum specified load A CCC approved power cord must be used to power this equipment when used in China CAUTION These servicing instructions are for use by qualified service personnel only To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so C2604M 7 06 The product and or manual may bear the following marks A This symbol indicates that dangerous voltage constituting a risk of electric shock is present CAUTION RISK OF ELECTRIC SHOCK A This symbol indicates that there are important DO NOT OPEN operating and maintenance instructions in the literature accompanying this unit 2604 7 06 5 Regulatory Notices This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation RADIO AND TELEVISION INTERFERENCE This equipment has been tested and found to comply with the limits of a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This e
22. for credit and RA number if returned for repair All merchandise returned for credit may be subject to a 20 restocking and refurbishing charge Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid Ship to the appropriate address below If you are located within the continental U S Alaska Hawaii or Puerto Rico send goods to Service Department Pelco 3500 Pelco Way Clovis CA 93612 5699 If you are located outside the continental U S Alaska Hawaii or Puerto Rico and are instructed to return goods to the USA you may do one of the following If the goods are to be sent by a COURIER SERVICE send the goods to If the goods are to be sent by a FREIGHT FORWARDER send the goods to Pelco Pelco c o Expeditors 3500 Pelco Way 473 Eccles Avenue Clovis CA 93612 5699 USA South San Francisco CA 94080 USA Phone 650 737 1700 Fax 650 737 0933 REVISION HISTORY Manual Date Comments C2604M 7 06 Original version Pelco the Pelco logo Camclosure Esprit Genex Legacy and Spectra are registered trademarks of Pelco Endura and ExSite are trademarks of Copyright 2006 Pelco DLP is a registered trademark of Texas Instruments Inc All rights reserved PELLI Worldwide Headquarters 3500 Pelco Way Clovis California 933612 USA USA amp Canada Tel 800 289 9100 Fax 800 289 9150 International Tel 1 559 292 1981 Fax 1 559 348 1120 www pelco
23. he Products Pelco s iability for any claim whether based on breach of contract negligence infringement of any rights of any party or product liability relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products In no event will Pelco be liable for any special incidental or consequential damages including loss of use loss of profit and claims of third parties however caused whether by the negligence of Pelco or otherwise he above warranty provides the Dealer with specific legal rights The Dealer may also have additional rights which are subject to variation from state to state a warranty repair is required the Dealer must contact Pelco at 800 289 9100 or 559 292 1981 to obtain a Repair Authorization number RA and provide the following information Model and serial number 2 Date of shipment number Sales Order number or Pelco invoice number 3 Details of the defect or problem there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above please include a written explanation with the product when returned Method of return shipment shall be the same or equal to the method by which the item was received by Pelco RETURNS In order to expedite parts returned to the factory for repair or credit please call the factory at 800 289 9100 or 559 292 1981 to obtain an authorization number CA number if returned
24. ounting of an additional module It is recommended that a maximum of three expansion kits be used with the base kit allowing a maximum of four single width modules to be mounted to a wall NOTE The WM5001 wall mount kits can be used with the WM5002 wall mount kits which are designed for mounting of double width fiber optic modules If mounting a mix of single width and double width modules is desired it is recommended that a maximum of two single width modules and one double width module be mounted in combination with one another For mounting instructions using the wall mount kits refer to the WM5000 Series Wall Mount Kit Installation manual C2604M 7 06 Mounting the Transmitter Receiver Using the Wall Clip NOTE Before mounting the FT85011A transmitter FR85011A receiver to a wall ensure that there is adequate space at both ends for viewing the front panel LEDs and for making the various rear panel cable connections To attach the FT85011A transmitter FR85011A receiver to a wall using the supplied wall clip refer to Figure 5 and do the following 1 Using the two vertical or horizontal wall mounting holes attach the wall clip to a wall using two screws not provided 2 Slide the module into the clip until the two holes on the bottom of the module align with the two holes on the lower flange of the clip 3 Attach the module to the clip using the two Phillips pan head screws provided for the clip EA te
25. quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission s rules This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada C2604M 7 06 0verview DESCRIPTION The FT85011A FR85011A fiber transmitter and receiver provide the ability to transmit one unidirectional composite video channel and one bidirectional data channel over one optical fiber In addition patent pending technology provides the solution for allowing Coaxitron pan tilt zoom PTZ control data to be transmitted the full distance of the fiber up to 6 km for multimode fiber and up to 46 km for single mode fiber Figure 1 illustrates FT85011A transmitter and FR85011A receiver single channel video and data applications ONE ONE VIDEO VIDEO INPUT OUTPUT FT85011A FR85011A 779 ET RECEIVER DATA FIBER DATA SINGLE CHANNEL VIDEO AND BIDIRECTIO
26. r connection module is rack mounted reseat module or power supply as necessary Power supply has failed Replace power supply Loss of power occurs due to tripped circuit breakers blown fuses or faulty electrical service Check circuit breakers fuses or electrical service as necessary Video Present LED Green Incoming video signal is present on the channel No action required Red on transmitter Incoming video signal is not present on the channel Video source is not powered on Check power connection to the video source Video source is not connected to the transmitter Check BNC connections Coaxial cable is defective Replace cable Red on receiver Incoming video signal is not present on the channel Optical signal is not being received from the trans mitter Optic Fault LED is also red Refer to the Optic Fault LED section in this table Video source is no powered on Check power connection to the video source Video source is no connected to the transmitter Check BNC connections Coaxial cable connected to the transmitter is defective Replace cable 24 Continued on next page 2604 7 06 Table Troubleshooting with Front Panel Indicators Continued Indicator Color Meaning Possible Cause Corrective Action Optic Fault LED Green The optical signal is
27. the safety purpose of the polarized grounding type plug A polarized plug has two blades with one wider than the other A grounding plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the 0 P bsolete outlet otect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the points where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus When a cart is used use caution when moving the cart apparatus combination to avoid injury from tip over Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus WARNING reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture Installation should be done only by qualified personnel an
28. upport Continued on next page 25 Table Troubleshooting with Front Panel Indicators Continued Indicator Color Possible Cause Corrective Action Data Tx LED Flashing amber Data is being trans mitted onto the fiber by the data port No action required Red Data Selection switch is set to an invalid setting Data Selection switch is set setting 6 7 8 or 9 Set Data Selection switch to the correct setting for the desired data communication refer to Table A Not lit Data is not being Data is not present on the No action required transmitted onto the channel fiber by the data Data connection is faulty Check data connections port TET Data communication cable Replace cable is defective Data Rx LED Flashing amber Data is being action required received from the fiber by the data port Red Data Selection Data Selection switch is set Set Data Selection switch to switch is set to an 0 setting 6 7 8 or 9 the correct setting for the invalid setting desired data communication refer to Table A Not lit Data is not being Data is not present on the No action required received from the channel fiber by the data Data connection is faulty Check data connections port UT Data communication cable Replace cable is defective 26 C2604M 7 06 Specifications VIDEO Number of Channels Modul
29. vironments with relative humidity above 95 condensing No performance adjustments required 12 VDC or 24 VAC power supply Stand alone and rack mountable modular design LED indicators for monitoring of signal status laser status data activity and operating power In addition note the following The FT85011A transmitter FR85011A receiver is a Class 1 laser product that complies with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825 1 Edition 1 2 2001 08 In addition to compatibility with each other the FT85011A transmitter and the FR85011A receiver are compatible with other fiber models FT85011A transmitter is backward compatible with the FR85011 receiver FR85011A receiver is backward compatible with the FS85011 and FT85011 transmitters For optical power budget and maximum transmission distance specifications of the various module compatible pairs refer to the Specifications section For additional information about the FR85011 FS85011 and FT85011 modules refer to the manual supplied with the modules C2604M 7 06 MODELS The FT85011A FR85011A fiber transmitter and receiver consist of the following series of models Multimode Models FT85011AMSTR Single channel fiber optic video transmitter data transceiver multimode ST connector FR85011AMSTR Single channel fiber optic video receiver data transceiver multimode ST connector Single Mode Models FT85011ASS