1. N m E co O D N N LO D lt q N m lt T oO D oO N de Fes e e Ps fee si fes fri Mus f oz Tu 16 A 5 LED INDICATORS e Eight LED indicators e Power e WAN Link Transmit and Receive e Ethernet Link 100M Transmit and Receive A 6 POWER AND POWER SUPPLY SPECIFICATIONS e Either AC or DC options are available e Connection to the CopperLink Ethernet Extender requires 5VDC 5 DC power 1 0A minimum Center pin is 5V The barrel type plug has a 2 5 5 5 10mm D O D shaft length dimensions e CopperLink Ethernet Extender s rated voltage 5 0 VDC e CopperLink Ethernet Extender s rated current 1A DC A 7 ENVIRONMENTAL e Temperature 32 122 F O 50 C e Relative Humidity 5 90 non condensing e Altitude 0 15 000 ft 0 4 572 m A 8 DIMENSIONS 1 5H x 4 2W x 5 8D in 3 8H x 10 6W x 14 8D cm APPENDIX B MODELS 2156 AND 2157 SERIES FACTORY REPLACEMENT PARTS AND ACCESSORIES 2156 Base Models 2156 L CopperLink Ethernet Extender Line RJ 11 Local 2156 R CopperLink Ethernet Extender Line RJ 11 Remote 2156 2PK CopperLink Ethernet Extender Kit includes one local L and one remote R Model 2156 2157 Base Models 2157 L CopperLink Ethernet Extender Line RJ 11 Local 2157 R CopperLink Ethernet Extender Line RJ 11 Remote 2157 2PK CopperLink Ethernet Extender Kit includes one local L and one remote R Model 2157 2156 and 2157
2. with an AC or DC power supply e The supplies connection to the CopperLink Ethernet Extender is a 2 5 mm barrel receptacle with the center conductor positive see Figure 6 Power o e S Figure 8 Power connection barrel receptacle diagram e CopperLink Ethernet Extender s rated voltage 5 0 VDC e CopperLink Ethernet Extender s rated current 1 A DC External AC universal power supply e Output from power supply 5 VDC 2A e Input to power supply universal input 100 240 VAC 50 60 Hz 0 3A An approved external power supply that incorporates a disconnect device must be used and positioned within easy reach of the operators position Caution Connect the equipment to a 5 VDC source that is electri cally isolated from the AC source The 5 VDC source is to be reliably connected to earth Caution External 48 VDC power supply e Input Rated voltage 36 60 VDC Rated current 0 25 A DC at nominal 48 VDC 93 pin locking connector 3 5 mm pitch Reverse polarity protection Transient over voltage protection 100 VDC at 2 ms e Output Rated voltage 5 VDC 5 5W Rated current 1 DC 6 inch cable terminated with 2 5 mm barrel plug center positive An approved external power supply that incorporates a disconnect device must be used and positioned within easy reach of the operators position Caution Connect the equipment to a 36 60 VDC source that is electrically isolated from the AC sou
3. 1 CONNECTING THE TWISTED PAIR LINE INTERFACE The Models 2156 and 2157 support communication between two peer Ethernet LAN sites over a distance greater than 30 000 ft 9 144 m over 24 AWG 0 5 mm twisted pair wire Note The Models 2156 and 2157 use an auto rate adaption feature to provide the fastest data rate possible over the wire and distance of each Ethernet extension The actual distance and rate achieved for Ethernet extension may vary depending on the environment and type gauge of the wire used Follow the steps below to connect the CopperLink interfaces Note The Model 2156 or 2157 units work in pairs One of the units must be a Model 2156 L local or 2157 L and the other unit must be a Model 2156 R remote or 2157 R 1 To function properly the two Ethernet Extenders must be connected together using twisted pair unconditioned dry metal wire between 19 0 9mm and 26 AWG 0 4mm Leased circuits that run through signal equalization equipment are not acceptable 2 The Models 2156 and 2157 are equipped with an RJ 11 interface The CopperLink interfaces are a two wire interface Observe the sig nal pin relationships on the CopperLink interface jack The RJ 11 connector on the CopperLink Ethernet Extender s twisted pair interface is polarity insensitive and is wired for a two wire interface The signal pin relationship is shown in Figure 3 1 No Connection 2 2 Wire RING 3 2 Wire TIP EE 4 No Connection Fi
4. ISO M An ISO 9001 Certified Company Part 07M2156 2157 Doc 032131U Rev A Revised 2 4 03 USER MANUAL MODELS 2156 amp 2157 CopperLink Ethernet Extenders ink Ethernet Extender pa PATTON copper rs wae SES SF ean L Ethemet DE PATTON HE Electronics To SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 CONTENTS 1 0 1 1 1 2 1 3 1 4 1 5 2 0 2 1 2 2 3 0 3 1 3 2 3 3 3 4 C 2 Warranty Information ss sssssssrrssrnsercennnnneeennnnnns 3 Radio and IV Int rt rence sisia tesscace var enciaucuasntentwetads teucssiareoes 3 GE NOICE sienne ee arte nee dites 3 FC GP Alt OS LES SR et ee Soit 4 Industry Canada Notice 5 DOIVIC ae tn a nets 5 General INFOrmation siccscvaicecissvecececacaceacsaccivetsapensachecacsvacceesesnaeat 6 Feats inc tt eee Marea ciate cela ed sn 6 D SCHPUIODALS SR se veer ee a ents enone te er ore 6 LETS Fel ARION ana veces seesduceesseacaseasuatenenmenaunentet 8 Connecting the Twisted Pair Line Interface 8 Line Interface Connecting the 10 100Base T EINECS INTE ACC ne ne her net ne 9 Connecting the 10 100Base T Ethernet Port to a PUDO PO A M eat ne A 10 Connecting POWER runs ete tement 11 Power Input Connector 11 External AC universal power SUpply 11 External 48 VDC power Supply 12 CONSO PORN a Line dar 13 OCT AU OMe eee ees 14 F
5. REN No 0 2 Your telephone company may make changes to its facilities equip ment operations or procedures that could affect the proper func tioning of your equipment The telephone company will notify in advance of such changes to give you an opportunity to maintain uninterrupted telephone service If your Model 2156 or 2157 causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance but if advance notice is not practical you will be notified as soon as possible and will be informed of your right to file a complaint with the FCC If you experience trouble with the Model 2156 or 2157 contact Pat ton Electronics Company for service or repairs Repairs should be performed only by Patton Electronics Co You are required to notify the telephone company when you discon nect the Model 2156 or 2157 from the network 1 4 INDUSTRY CANADA NOTICE NOTICE This equipment meets the applicable Industry Canada Termi nal Equipment Technical Specifications This is confirmed by the registra tion number The abbreviation C before the registration number signifies that registration was performed based on a Declaration of conformity indicating that Industry Canada technical specifications were met It does not imply that Industry Canada approved the equipment 1 5 SERVICE All warranty and non warranty repairs must be returned freight prepaid and ins
6. User Manual 07M2156 2157 User Manual Power Supplies 08055DCUI 100 240VAC 5V reg DC 2A Universal Input Adapter Power Cords Switzerland Power Cord Only required with optional Ul power supply O8055DCUI APPENDIX C MODELS 2156 AND 2157 SERIES INTERFACE PIN ASSIGNMENT C 1 10 100BASE T INTERFACE RJ 45 Pin 1 TX Pin 2 TX Pin 3 RX Pin 6 RX Pins 4 5 7 8 no connection 1 TX data output from 2156 2157 1 ee 2 TX data output from 2156 2157 2 3 RX data input to 2156 2157 4 4 no connection 9 5 no connection ii 6 RX data input to 2156 2157 7 8 7 no connection 8 no connection C 2 COPPERLINK INTERFACE RJ 11 Pin 2 RING Pin 3 TIP e Pins 1 amp 4 no connection 1 No Connection 2 2 Wire RING 3 2 Wire TIP 4 No Connection Notes Copyright 2002 Patton Electronics Company AIT Rights Reserved 20
7. e receiving antenna and or plugging the receiving equipment into a different AC out let such that the computing equipment and receiver are on different branches 1 2 CE NOTICE The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility EMC directive and the Low Voltage Directive LVD of the European Union EU A Cer tificate of Compliance is available by contacting Technical Support FCC PART 68 The Models 2156 and 2157 are not intended to be con nected to the public telephone network Caution You are required to request service from the telephone company before you connect the Model 2156 or 2157 to a network When you request service you must provide the telephone company with the following data The required Universal Service Order code USOC jack RJ 11C The make model number Ringer Equivalence Number REN and FCC Registration number of the Model 2156 or 2157 The REN helps you determine the number of devices you can con nect to your telephone line and still have all of those devices ring when your number is called In most but not all areas the sum of the RENs of all devices should not exceed five 5 0 To be certain of the number of devices you can connect to your line you should call your local telephone company to determine the maximum REN The Facility Interface Code 02LS2 The Service Order Code s SOC 9 0F
8. ernet Unlimited host support Eight front panel LEDs indicate Power WAN Ethernet LAN speed and status Convenient and standard RJ connectors for Ethernet and line External UI or 48 VDC power supply options Standard 1 year warranty A 2 WAN CHARACTERISTICS 2 3 Mbps Model 2156 or 4 6 Mbps speed Model 2157 RJ 11 connector Uses two wire unconditioned twisted pair A 3 ETHERNET Full duplex auto sensing 10Base T 100Base TX Ethernet Standard RJ 45 and built in MDI X crossover switch IEEE 8021 d transparent learning bridge up to 1 024 addresses and Spanning tree Compatible with 802 1Q VLAN Addresses deleted after 5 minutes of inactivity see adjusting rate picks best rate for a given extension distance Table 2 Model 2156 Extension Distances tables below e 2 3 Mbps Model 2156 or 4 6 Mbps speed Model 2157 e Distances up to 30 000 ft 9 144 m on 24 AWG 0 4 mm wire A 4 EXTENSION DISTANCE AND RATE e Auto gt LO 2 i 2 je 2 Mm L ven q Pe Z Se N a A 10 8 9 8 6 4 29 O O Cc a 2 Q Cc 2 Oo Cc gt x lt LL N LO N TD O o 2 GC FF Cum E D Oo E E oO D N m E To D N N E E LO D N m E lt q oO D co N 2312 0 0a 3848 4232 T DSL line 4 OCHE ole DORG Bo E o oO D o E co O D
9. gure 3 CopperLink Ethernet Extender RJ 11 twisted pair line interface 3 2 LINE INTERFACE CONNECTING THE 10 100BASE T ETHERNET INTERFACE The shielded RJ 45 port labeled fhernefis the 10 100Base T interface This port is designed to connect directly to a 10 100Base T network Figure 4 shows the signal pin relationships on this interface You may connect this port to another Ethernet device via a Type 4 or Type 5 cable that is up to 328 ft 100 m long 1 TX data output from 2156 2157 1 an 2 TX data output from 2156 2157 2 sl 3 RX data input to 2156 2157 4 4 no connection 9 5 no connection 6 RX data input to 2156 2157 8 oS 7 no connection o 8 no connection Figure 4 CopperLink Ethernet Extender 10 100Base T RJ 45 Connector Pinout Connecting the 10 100Base T Ethernet Port to a Hub or PC The Models 2156 and 2157 are equipped with an MDI X switch that enables connections to a hub DCE or PC DTE interface thereby elimininating confusion over whether a straight through or crossover cable is needed When using a straight through cable for connecting to a hub the MDI X switch should be in its released DCE mode position see Figure 5 When connecting to a PC the MDI X switch should be pushed in to engage the crossover function so you won t have to use a crossover cable __ mm DITE mode MDI X switch EE DCE mode Figure 5 MDI X switch positio
10. ns Note Ifyou have difficulty achieving a working connection between the CopperLink Ethernet Extender s Ethernet port and the hub or PC change the position of the MDI X switch and try again In its released position the MDI X switch enables straight through con nections see Figure 6 or in its inserted position the MDI X switch per forms the crossover function see Figure 7 on page 11 2157 10 100Base T Port 10 100Base T Hub RJ 45 Pin No RJ 45 Pin No TX 1 RX 2 TX 2 RX 3 RX 3 TX 6 RX 6 TX Figure 6 Wiring diagram for connecting the CopperLink Ethernet Extender to a 10 100Base T hub MDI X switch released 10 2157 10 100Base T Port 10 100Base T DTE RJ 45 Pin No RJ 45 Pin No 1 TX 1 TX 2 TX 2 TX 3 RX 3 RX 6 RX 6 RX Figure 7 MDI X switch pressed in performs 10 100Base T crossover function 3 3 CONNECTING POWER An external AC or DC power supply is available separately This connec tion is made via the barrel jack on the rear panel of the Models 2156 and 2157 No configuration is necessary for the power supply See Appendix B on page 18 for domestic and international power supply and cord options 3 4 POWER INPUT CONNECTOR The CopperLink Ethernet Extender comes
11. rLink Ethernet Extenders provide high speed LAN connections between peered Ethernet LANs remote PCs or any other network enabled 10 100Base T device Operating in pairs a Model 2156 or 2157 can automatically forward LAN broadcasts multicasts and frames across a 2 wire voice grade twisted pair link The data is passed transparently unmodified through the Ether net Extenders They automatically add and delete MAC addresses only passing packets across the CopperLink line that are meant for the remote peered LAN VLG N LG NA Figure 1 Typical application The 2157 L and 2157 R work together to create a transparent extension between two peered Ethernet LANs Figure 1 shows a typical point to point application 3 0 INSTALLATION Because the CopperLink Ethernet Extenders require no configuration they can be installed quickly Installation consists of the following e Connect the line interface between the units refer to section 3 1 Connecting the Twisted Pair Line Interface on page 8 Note See Figure 2 for the rear panel connectors locations e Connect the Ethernet interface refer to section 3 2 Line Interface Connecting the 10 100Base T Ethernet Interface on page 9 e Connect the power plug refer to section 3 3 Connecting Power on page 11 Line port Console port Ethernet port Figure 2 CopperLink Ethernet Extender rear panel 3
12. rce The 36 60 VDC source is to be reliably connected to earth Caution 3 5 CONSOLE PORT The Console Port is only intended for use by Patton Electronics Technical Support technicians 4 0 OPERATION Once the CopperLink Ethernet Extenders are properly installed they should operate transparently No user settings required This section describes reading the LED status monitors 4 1 FRONT PANEL LED STATUS MONITORS The Models 2156 and 2157 feature eight front panel LEDs that monitor power Ethernet signals and the CopperLink connection Figure 9 shows the front panel location of each LED Table 1 describes the LED functions LS Ethernet Rx LED Ethernet Tx LED wan WAN i Link Rx Ethernet LED LED 100 M LED Power WAN Ethernet LED Tx Link LED LED Figure 9 CopperLink Ethernet Extender standalone unit front panel Table 1 Front panel LED description When lit indicates the unit is powered on WAN Link e On solid link is connected e Off No signal detected Flashing Data is being transmitted from the local unit to the RX remote unit Flashing Data is being received at the local unit from the remote unit Ethernet On Ethernet is linked On 100 Mbps Ethernet is selected Flashing When data is transmitted from the unit to the LAN Flashing When data is received from the LAN APPENDIX A SPECIFICATIONS A 1 GENERAL CHARACTERISTICS Compact low cost plug and play router 10 100 Eth
13. ront Panel LED Status Monitors cccccssseecssseeeesseetenseetans 14 SDECITICALIONS 555 ele ete ee ee et 15 G n ral CharaCleriSuCs as ira L nine 15 WAN Chiat aCleniSiCS as en a dei 15 PRENET ae see a a AA E eek ras Salts Sto oe ibs Extension distance ANC rate ce ccecccseeecseeecaeeeeaeseeeeeeeneeeeneees 16 LE PSCC ONS tak Sect ished ener eaten a a nent 17 Power and Power Supply Specifications oo cece ccceeceeeeeeeees 17 AMITOHANOTHAIRES SRE RSS RS eu te 17 DIMENSIONS Er A RS let ese ata hs tata RS Ae arta peta insted ac tatu 17 Models 2156 and 2157 Series Factory Replacement Parts and Accessories 18 Models 2156 and 2157 Series Interface Pin Assignment 19 lOMOOBAS ET INE Aer eee al eo 19 PS a Ra rt de te 19 CopperLink Interface ccc cc cee ccce ee ecee ee eeeeseeeesseeeeseneeeene estan 19 a a a Mi a A E E A T E E AA E E 19 1 0 WARRANTY INFORMATION Patton Electronics warrants all Model 2156 or 2157 components to be free from defects and will at our option repair or replace the product should it fail within one year from the first date of the shipment This warranty is limited to defects in workmanship or materials and does not cover customer damage abuse or unauthorized modification If this product fails or does not performs as warranted your sole recourse shall be repair or replacement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the u
14. se of this product These damages include but are not limited to the following lost profits lost savings and incidental or consequential damages arising from the use of or inability to use this product Patton Electronics spe cifically disclaims all other warranties expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user Note Conformity documents of all Patton products can be viewed online at www patton com under the appropriate product page 1 1 RADIO AND TV INTERFERENCE The Model 2156 or 2157 generate and use radio frequency energy and if not installed and used properly that is in strict accordance with the manufacturer s instructions may cause interference to radio and televi sion reception The Models 2156 and 2157 have been tested and found to comply with the limits for a Class A computing device in accordance with specifications in Subpart B of Part 15 of FCC rules which are designed to provide reasonable protection from such interference in a commercial installation However there is no guarantee that interference will not occur in a particular installation If the Model 2156 or 2157 does cause interference to radio or television reception which can be deter mined by disconnecting the unit the user is encouraged to try to correct the interference by one or more of the following measures moving the computing equipment away from the receiver re orienting th
15. ured to Patton Electronics All returns must have a Return Materi als Authorization number on the outside of the shipping container This number may be obtained from Patton Electronics Technical Services at e Telephone 1 301 975 1007 e Email support patton com URL http www patton com Technical support is available from 8 AM to 5 PM EST 8 00 to 17 00 UTC 5 Monday through Friday Note Packages received without an RMA number will not be accepted 2 0 GENERAL INFORMATION Thank you purchasing this Patton Electronics product This product has been thoroughly inspected and tested and is warranted for one year for parts and labor If questions arise while installing or using this product contact Technical Support at 1 301 975 1007 2 1 FEATURES e Easy to install Ethernet Extenders 70 configuration required e Auto rate adaption ensures the highest rate possible for each exten sion distance e Data rates to 2 3 Mbps for Model 2156 and 4 6 Mbps for Model 2157 e Auto sensing 10 100Base T e Extends network connections up to 30 000 ft 9 144 m over 2 wire 24 AWG unconditioned lines see Appendix A on page 15 Transparent operation to higher level protocols such as TCP IP DEC net NETBIOS IPX etc e Compatible with 802 1Q VLAN e LED indicators for Power Ethernet Link 100Base T Operation Transmit Receive WAN Link Transmit Receive e Made in the USA 2 2 DESCRIPTION The Patton Electronics Coppe
Download Pdf Manuals
Related Search
Related Contents
BENDIX BRIP-0890 User's Manual メタクレゾール “ ” や っ め 融 やけや火災 直後 物触 やけ 取扱時 乾燥庫乾燥炉か出 際 CONTRATO Nº 00001 CONTRATO DE LOCAÇÃO cahier des charges informatique protide Moçambique Secção IX Memória descritiva the QuattroFlow 20K User Manual Tecumseh AGA5549CXT Technical Data Sheet Downloads - OMEGA Engineering Flash - TAG - Techniques Audio Groupe Copyright © All rights reserved.