Home

Paradyne 916x Network Card User Manual

image

Contents

1. NN NET TO NET TECHNOLOGIES Interface Module User Guide SAM2000G 12 12 Port SHDSL Access Multiplexer Also SAM2000Q 12 2B1Q and SAM2000 12 CAP 1 0 SDSL ACCESS MODULE MODELS SDSL access multiplexers are intended for use in Net to Net Technologies IPD12000 and IPD4000 DSLAMs Model types vary by the SDSL line code utilized 1 1 SAM2000G 12 The SAM2000G 12 operates with Transmission Convergence Pulse Amplitude Modulation TC PAM line code a sixteen level PAM technique which incorporates advanced Trellis code precoding spectral shaping equalization circuits and forward error correction Otherwise known as G SHDSL or SHDSL 1 2 SAM2000Q 12 The SAM20000 12 operates with Two Binary One Quaternary 2B1Q line code a four level PAM technique which reduces the signaling rate to half of the bit rate 1 3 SAM2000 12 The SAM2000G 12 operates with Carrierless Amplitude and Phase CAP modulation line code transmit and receive signals are modulated into two wide frequency bands that can pass through a filter without being attenuated NOTE Throughout this document SAM2000G is utilized to indicate all three SDSL access multiplexer models information given applies to all three models except as individually stated or otherwise noted 210 0000026 revO7 2 0 INSTALLATION CAUTION Net to Net Technologies strongly recommends the use of proper electrostatic discharge ESD precautions when handling this equipment 2 1 Un
2. either directly through the 10 100 Ethernet MGMT port on the MUM faceplate or if your DSLAM has been configured to allow inband management across your local network For direct connections verify that the MGMT LNK LED on the MUM faceplate is illuminated 4 2 2 Launch Your Web Browser Launch a web browser on your PC such as Microsoft Internet Explorer or Netscape Navigator 4 2 3 Enter Your DSLAM s IP Address Enter the DSLAM s IP Address into the address field at the top of your browser window and press the Enter key 210 0000026 revO7 4 2 4 LogIn Log in with your assigned username and password For SAM2000G configuration you must log in as a Superuser general users have read only access If your username and or password are unknown contact your System Administrator or Information Technology Manager for assistance Once you have logged in as a superuser you will be able to make configuration changes to the SAM2000G and any other interface modules installed in your IP DSLAM as desired For more detailed information regarding SAM2000G configuration via NMS refer to Net to Net s NMS Management User Guide http www nettonet com support docs 210 0000048 4 3 Via Simple Network Management Protocol SNMP NOTE The MUM200 2 does not have SNMP capabilities you must have a MUM2000 2 installed in your IP DSLAM in order to access DSLAM management or any interface modules via SNMP 4 3 1 Establish a Connection With Your IP DS
3. 13 IP Address IPD12000 Slot 14 192 168 254 252 192 168 254 253 IP Address IPD4000 Slot 5 192 168 254 252 Management IP Address Filter Range 0 0 0 0 255 255 255 255 all Subnet Mask 3 2 SAM2000G Port Parameters PARAMETER DEFAULT CONFIGURATION 255 255 255 0 Circuit Identification n a no default Back bone VLAN 0 off Flood uplink IP Range 1 0 0 0 0 255 255 255 255 all IP Range 2 0 0 0 0 0 0 0 0 Priority VLAN 0 none Protocol all Speed 272 kbps VLAN Range 0 O off 4 0 SAM2000G MANAGEMENT Once your SAM2000G has been installed bandwidth and other configurations are software selectable via your IP DSLAM s MUM Dependent upon the MUM model installed the SAM2000G may be configured via Command Line Interface CLI Simple Network Management Protocol SNMP and or Net to Net Technologies web based Network Management System NMS If your IP DSLAM is newly installed configuration of the DSLAM s IP Address Subnet Mask and Gateway must be completed via CLI or NMS before you will be able to access management data or configure any other parameters Refer to the CLI Management User Guide http www nettonet com support docs 210 0000052 or to the NMS Management User Guide http www nettonet com support docs 210 0000048 for initial configuration instructions 210 0000026 revO7 NOTE If you have an IPD12000 with two MUMs configuration alte
4. unless changed via CLI NMS or SNMP Once changed new configurations are automatically recorded in both RAM and NVRAM 6 1 1 Memory 6 1 1 1 Random Access Memory RAM Data stored in SAM2000G RAM will be erased if the module is removed from your IP DSLAM or if your IP DSLAM loses power 6 1 1 2 Non Volatile Random Access Memory NVRAM Data stored in the NVRAM of your IP DSLAM s MUM will remain intact even if your IP DSLAM loses power unless deliberately cleared or reconfigured 6 1 2 Local Files Management and interface module configurations can be saved on your PC or local network both as a backup and or for use as a template for future configurations via the MUM in your IP DSLAM Management configurations and all interface module port configurations are saved 210 0000026 revO7 concurrently SAM2000G configurations cannot be saved independently Once your IP DSLAM has been configured as desired including the SAM2000G settings can be flash uploaded to a local file through a Trivial File Transfer Protocol TFTP tool with a GET command and the following information 6 1 2 1 Backup An IP DSLAM backup file records ALL management and port configurations ITEM DATA NEEDED FOR BACKUP EXAMPLE Host Name DSLAM_IP Address XXX XXX XXX XXX 193 166 254 98 Remote Filename NVR_BACKUP BIN superuser password nvr_backup bin Password Local Filename user preference dslam27_mum13_backup bin 6 1 2 2 Template An IP DSLAM temp
5. LAM Establish a connection between your IP DSLAM and your PC either directly through the 10 100 Ethernet MGMT port on the MUM faceplate or if your DSLAM has been configured to allow inband management across your local network For direct connections verify that the MGMT LNK LED on the MUM faceplate is illuminated 4 3 2 Launch Your MIB Browser Launch a MIB browser program on your PC If you have not yet downloaded the necessary MIBs to your PC or local network you can obtain the Net to Net enterprise MIBs from ftp ftp nettonet com download mibs and the supported portions of MIB II from the Internet Engineering Task Force RFC 1213 at http www ietf org rfc html After downloading the MIBs you will need to compile them into your MIB browser refer to your MIB browser user manual for further instruction Once the MIBs have been compiled you will be able to make configuration changes to the SAM2000G and any other interface modules installed in your IP DSLAM as desired For more detailed information regarding SAM2000G configuration via SNMP refer to Net to Net s SNMP Management User Guide http www nettonet com support docs 210 0000053 5 0 BANDWIDTH AND DISTANCE NOTE Parameters common to all interface module models are defined in the CLI NMS and SNMP Management User Guides Bandwidth however is specific to the SAM2000G 12 SAM2000Q 12 and SAM2000 12 210 0000026 revO7 The SAM2000G 12 SAM2000Q 12 and SAM2000 12 e
6. ach have nine SHDSL bandwidth options default is 272 kbps Distance capabilities at each bandwidth vary dependent upon the type of line code being utilized Distances listed below assume the use of 26 American Wire Gauge AWG cable connections made with cable of a greater gauge will link up at greater distances The ports on your module may not link up if your cables are in poor condition or if cable distances are greater than the configured bandwidth will support Although it is sometimes possible for links to be achieved under such conditions traffic quality may be effected e g packets may be dropped SHDSL BANDWIDTH kbps 2 320 2 064 1 552 1 040 784 528 400 272 144 SAM2000G 12 feet 11 300 12 200 12 800 16 000 16 800 18 400 19 400 20 200 25 400 TC PAM line code SHDSL meters 3 444 3 719 3 901 4 877 5 121 5 608 5 913 6 157 7 742 Distance SAM2000Q 12 feet 10 400 10 800 13 400 14 800 15 800 17 400 18 200 19 200 23 800 2B1Q line code meters 3 170 3 292 4 084 4 511 4 816 5 304 5 547 5 852 7 254 RETE feet 11 000 11 900 12 600 15 500 16 000 17 900 18 900 23 100 24 700 CAP line code meters 3 353 3 627 3 840 4 724 4 877 5 456 5 761 7 041 7 529 6 0 ADDITIONAL INFORMATION 6 1 Data Storage Configuration backup is inherent in Net to Net Technologies IP DSLAMs SAM2000G default parameters remain in place
7. he user will be required to correct the interference at his own expense Caution Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment 6 3 2 Industry Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la Classe A est conforme a la norme NMB 003 du Canada 6 3 3 Europe This Class A product complies with European Norm EN55022 Warning In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct the situation 210 0000026 revO7 210 0000026 rev07 Copyright 2003 Net to Net Technologies Inc The Net to Net Logo is a trademark of Net to Net Technologies Inc Worldwide Headquarters Net to Net Technologies 112 Corporate Drive Portsmouth NH 03801 USA 1 877 638 2638 210 0000026 revO7 http www NetToNet com Contact NetToNet com EMEA Headquarters Net to Net Technologies Victoria House 19 Park Way Newbury Berkshire RG14 1EE UK 44 0 1635 570950
8. late file records all management and port configurations EXCEPT the MUM s IP Address ITEM DATA NEEDED FOR BACKUP EXAMPLE Host Name DSLAM_IP Address xxx xxx XXX XXX 193 166 254 98 Remote Filename NVR_CFG BIN superuser password nvr_cfg bin Password Local Filename user preference n2n_dslam12000_template bin Configuration files can also be flash downloaded FROM a local file TO an IP DSLAM simply replace the GET command with a PUT command Refer to your TFTP user manual for further instruction 6 2 LED Indications Power PWR solid green SAM2000G is If the Power LED is not illuminated it is unlikely operational that the SAM2000G 12 is receiving power in which case none of the LEDs will be illuminated SHDSL Link Lk pulsing SHDSL connection green is established and active The SHDSL link is operational and traffic is flowing solid green problematic SHDSL A connection exists but there is indication of a connection problem with the SHDSL line no no SHDSL illumination connection 210 0000026 revO7 ee ee ee SHDSL Data flashing SHDSL activity The port is receiving data from the remote Reception Rx amber SHDSL modem or statistical packets from your IP DSLAM s management solid amber heavy Rx traffic The port is receiving large amounts of data from the remote SHDSL modem or statistical packets from your IP DSLAM s management no no activity A link ma
9. nnected port will illuminate solid or pulsing green Link up time for connections between the SAM2000G and remote SHDSL modems can vary from one to five minutes depending on the quality gauge and distance of the copper cables Default bandwidth for the SAM2000G is 272 kbps 210 0000026 revO7 SHDSL RJ21 PORT PINOUT vores 2 2 5 6 7 e e Jela Ring 1 2 3 4 E 6 7 8 9 10 11 12 os fae oe 27 afs oo ar az faa eelas os gt pins 13 25 and 38 50 are not used 3 0 SAM2000G DEFAULT CONFIGURATIONS No configuration is necessary for the SAM2000G to operate at default settings 3 1 IP DSLAM Management 3 1 1 User Access NOTE All usernames and passwords are case sensitive 3 1 1 1 Network Management System NMS and Command Line Interface CLI ACCESS USERNAME PASSWORD read write superuser Password read only general Password 3 1 1 2 Simple Network Management Protocol SNMP ACCESS COMMUNITY STRING read write Password read only Password 3 1 2 Management Parameters The parameter defaults listed are common to all DSLAM MUM model types Some models have additional configuration possibilities refer to the User Guide and or Installation Instructions for your particular model 210 0000026 revO7 PARAMETER Gateway DEFAULT CONFIGURATION 0 0 0 0 Inband Management Inband Management VLAN ID off 0 off IP Address IPD12000 Slot
10. pack and Inspect the SAM2000G If there is visible damage do not attempt to connect the device contact Customer Support at 1 877 638 2638 1 603 427 0600 for international customers or Support nettonet com 2 2 Install the SAM2000G in an IP DSLAM Chassis NOTE There must be a Multiplexer Uplink Module MUM installed in your IP DSLAM chassis in order for interface modules to operate Net to Net Technologies IP DSLAM interface modules are hot swappable installing or removing an interface module while the chassis is powered up does not affect the operational status of other interface modules within the chassis The IPD12000 is a fourteen slot chassis slots 1 12 are for interface modules such as the SAM2000G slots 13 and 14 are reserved for MUMs Interface modules may be placed in any order in slots 1 12 The IPD4000 is a five slot chassis slots 1 4 are for interface modules slot 5 is reserved for a MUM e Align the SAM2000G with the module guides in the slot chosen for installation slot 1 12 on the IPD12000 or slot 1 4 on the IPD4000 e Slide the SAM2000G firmly into the chassis DO NOT USE EXCESS FORCE e Secure the SAM2000G by tightening the fastening screws on the module faceplate Verify that the PWR Power LED on the SAM2000G faceplate is illuminated 2 3 Connect the SHDSL Line s Plug the SHDSL cable into the RJ21 port of the chosen slot on the back of your IP DSLAM Verify your connections the SHDSL LK LED for each co
11. rations can be made to a SAM2000G through either MUM most configuration s will be saved to the NVRAM of both Refer to your MUM Installation Instructions for specifics 4 1 Via Command Line Interface CLI 4 1 1 Establish a Connection With Your IP DSLAM Establish a connection between your IP DSLAM and your PC either directly through the COM port on the MUM faceplate or if your DSLAM has been configured to allow inband management across your local network 4 1 2 Launch Your Terminal Emulator Launch a terminal emulator program on your PC Net to Net Technologies copyright information will appear on your screen followed by a request for username 4 1 3 LogIn Log in with your assigned username and password For SAM2000G configuration you must log in as a Superuser general users have read only access If your username and or password are unknown contact your System Administrator or Information Technology Manager for assistance Once you have logged in as a superuser you will be able to make configuration changes to the SAM2000G and any other interface modules installed in your IP DSLAM as desired For more detailed information regarding SAM2000G configuration via CLI refer to Net to Net s CLI Management User Guide http www nettonet com support docs 210 0000052 4 2 Via Net to Net s Network Management System NMS 4 2 1 Establish a Connection With Your IP DSLAM Establish a connection between your IP DSLAM and your PC
12. y exist but the port is not receiving illumination any data from the remote SHDSL modem or statistical packets from your IP DSLAM s management SSS SS ee SHDSL Data flashing SHDSL activity The port is transmitting data to the remote Transmission amber SHDSL modem Tx Tx solid amber heavy Tx traffic The port is transmitting large amounts of data to the remote SHDSL modem no no activity A link may exist but the port is not transmitting illumination any data to the remote SHDSL modem A pulsing LED blinks steadily at a rate of once per second A flashing LED blinks ata more rapid less constant rate 6 3 Regulatory Compliance for Class A Equipment The following regulatory compliance information applies to the SAM2000G 12 SAM2000Q 12 and or SAM2000 12 as installed in Net to Net Technologies IP DSLAMs 6 3 1 US Federal Communications Commission FCC Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case t