Home

NordicTrack 831.159770 Home Gym User Manual

image

Contents

1. About the Expansion Module for IP Phone 1100 Series This document describes the Expansion Module for IP Phone 1100 Series Expansion Module and how to use it with the IP Phone Description The Expansion Module is supported on the following IP Phones e IP Phone 1120E IP Phone 1140E IP Phone 1150E The Expansion Module is a hardware accessory that connects to the IP Phone and provides additional line appearances and feature keys Up to three modules are supported The IP Phone 1120E IP Phone 1140E and IP Phone 1150E can have up to 54 additional line feature keys with three Expansion Modules Figure 1 on page 8 shows the IP Phone 1140E with an Expansion Module attached About the Expansion Module for IP Phone 1100 Series Figure 1 IP Phone 1140E with Expansion Module 000000000000000000 Features The Expansion Module has the following features e 18 keys provide up to 36 additional self labeled line programmable feature keys when using the Shift feature Using the Shift key functionality an IP Phone 1140E for example can have up to 66 additional logical line feature keys Upgradeable firmware using a TFTP or a UFTP Server A desk mount bracket and structural baseplate support the connection of an Expansion Module for IP Phone 1100 Series to an IP Phone or to another Expansion Module IP Phone and Expansion Module combination can be wall mounted using the wall mount template provid
2. Controls and settings Controls and settings When an Expansion Module is installed on an IP Phone the controls and settings of the IP Phone control both the IP Phone and the Expansion Module Use the Telephone Options menu on the attached IP Phone to set the contrast and feature key labels of the Expansion Module For more information about controls and settings including the Telephone Options menu for your IP Phone see the IP Phone user guide Shift key functionality The IP Phone 1140E and IP Phone 1150E can also have up to 36 additional line feature keys using the Shift key functionality with one Expansion Module if the Communication Server supports the Shift feature If more than one Expansion Module connected the Shift key functionality does not affect the Expansion Module since the maximum number of line feature keys is already available The Shift Outbox key on the IP Phone 1120E is a fixed key that is reserved for future feature development Services key operation The Services key is used to access user settings and certain features on the IP Phone When one or more Expansion Module are attached to the IP Phone the actions of the display diagnostics for the IP Phones DN feature key display area are duplicated for the Expansion Module If an incoming call occurs when in the diagnostic mode the call is answered by pressing the DN feature key handsfree or headset key or by picking up the handset The display a
3. Note The second Expansion Module is attached to the right side of the first Expansion Module The third Expansion Module is attached to the right side of the second Expansion Module 5 Adjust the height of the IP Phone tilt adjustment to a comfortable viewing angle Then adjust each of the Expansion Module foot stands so they are flush to the desk surface Turn the wheel on the back right side of the Expansion Module to the right if viewed from the front to tighten the Expansion Module WARNING Do not over tighten the wheel on the Expansion Module 6 Connect power to the IP Phone The Expansion Module powers up Note The Expansion Module uses the electrical connection of the IP Phone for power It does not have its own power source Setup and assembly Expansion Module startup initialization Once the Expansion Module has been installed and powered up on the IP Phone the Expansion Module initializes Table 1 lists the initialization process for the Expansion Module Table 1 Initializing Expansion Module Phase Description Expansion The self test confirms the operation of the Module performs Expansion Module local memory CPU and other self test circuitry While undergoing this self test the Expansion Module display lights up Note If the Expansion Module display does not light up or lights up and then goes blank or fails to begin flashing check that the Expansion Module is correctly installed and co
4. Module IP Phone DN feature Diagnostic step key display area Expansion Module for IP Phone 1100 Series initial screen blank area display blank Full Contrast set to highest contrast set to highest contrast LED Test blank blank Character Test Characters display across the display areas the telephone on hook icon is displayed Characters display across the display areas the telephone on hook icon is displayed Regulatory and safety information Regulatory and safety information This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Conne
5. NORTEL Expansion Module for IP Phone 1100 Series User Guide 100000000000001 0000000001 NH 0000101010100000005 10101010 Revision history Revision history December 2006 Standard 01 02 This document is up issued to include updates based on feedback Expansion Module for the IP Phone 1100 series terminology has been updated December 2006 Standard 01 01 This document is up issued to include updates based on feedback Regulatory and safety information chapter was updated after a review This is a new user guide for the Expansion Module for the IP Phone 1100 series Revision history Contents About the Expansion Module for IP Phone 1100 Series 7 Description EE 7 FeatUf S sr reset rare ae na 8 Adjusting the display ee 9 Setup and assembly neee eeen 10 Installing the Expansion Module 222 22 e en 11 Expansion Module startup initialization 14 Using the wall mount option 0 000 c ee eee ee 14 Adjusting the tilt base een 15 Controls and settings oooocoooommmmmmmm o 16 Shift key functionality ee 16 Services key operation eneen 16 Display diagnostics nnee 17 Regulatory and safety information 19 OU 20 DenAn regulatory notice for Japan 2 222220 21 Terms you should know cece eee eee ee eee 23 About the Expansion Module for IP Phone 1100 Series
6. ct the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note The user should not make changes or modifications not expressly approved by Nortel Networks Any such changes could void the user s authority to operate the equipment This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada Warnings e This is a Class B product In a domestic environment this product can cause radio interference in which case the user must take adequate measures e Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device e Privacy of communications may not be ensured when using this telephone To prevent radio interference to the licensed service this device must be operated indoors only and should be kept away from windows to provide maximum shielding Regulatory and safety information ORLA HAUL SAE ERA VCCI DIMES 7 FA B RETE CORRI BERICHT DEE ERE LTRS 20 BNI VART VEV a RICA CEM ENDE BART HD EF HURL ACA CIE LV IRD BWE LC FAN Table 3 lists EMC compliance for various jurisdi
7. ctions Table 3 EMC compliance Jurisdiction Standard Description United States FCC CFR 47 Class B Emissions FCC Rules for Radio Part 15 Frequency Devices Canada ICES 003 Class B Emissions Interference Causing Equipment Standard Digital Apparatus Australia New AS NZS 3548 Class B Emissions Information technology Zealand CISPR 22 equipment Radio disturbance European EN 55022 Class B Emissions Information technology Community equipment Radio disturbance EN 55024 Information technology equipment Immunity characteristics Limits and methods of measurement EN 61000 3 2 Limits for harmonic current emissions equipment input current lt 16 A per phase EN 61000 3 3 Limitation of voltage fluctuations and flicker in low voltage supply systems for equipment with rated current lt 16 A Japan VCCI Regulations for voluntary control measures Other This equipment complies with the CE Marking requirements EU Countries This device complies with the essential requirements and other relevant provisions of EMC and LVD directives A copy ofthe Declaration may be obtained from http www nortel com products announcements eumrdc index html or Nortel Networks GmbH address Ingolstaedter Strasse 14 18 80807 Munich Germany Regulatory and safety information DenAn regulatory notice for Japan N Warning Please be careful of the following while installing the equipment e Please o
8. ed About the Expansion Module for IP Phone 1100 Series Adjusting the display The Expansion Module is equipped with a graphical pixel based grayscale LCD display area beside the 18 line feature keys see Figure 1 on page 8 Each of the 18 physical keys on the Expansion Module has a 10 character display label This label is set automatically however the user can edit the label using the controls on the IP Phone To adjust the display and contrast on the Expansion Module use the Contrast Adjustment option in the Telephone Options menu on the IP Phone Any contrast changes you make on the IP Phone affect the Expansion Module The Expansion Module and IP Phone do not have separate contrast adjustments The type of power supply to the phone controls what is functional on the Expansion Module for IP Phone 1100 Series The Expansion Module s backlight can only light when the local 48V power supply is present On the other hand either local 48V power supply or Power over Ethernet PoE to the phone will power all of the Expansion Module s other functionality For more information see the section Adjusting the screen display contrast in your IP Phone User Guide Setup and assembly Setup and assembly The Expansion Module mounts on the right side of the IP Phone The Expansion Module snaps into the Accessory Expansion Module AEM on the back of the IP Phone using the desk mount bracket and structural baseplate suppli
9. ed with the Expansion Module Setup and assembly Installing the Expansion Module Use the following instructions to install the Expansion Module CAUTION Damage to Equipment To avoid damaging the equipment remove the power PoE cable or local power from the IP Phone before connecting the Expansion Module CAUTION Damage to Equipment The Expansion Module is shipped with the base locked in position To avoid damaging the Expansion Module press the tilt lever located on the base at the front of the Expansion Module 4 Wall Mount Lever 1 Press the tilt lever to adjust the stand angle on the IP Phone You can adjust the stand angle to maximum instead of removing the stand See Figure 2 Setup and assembly Figure 2 Adjusting the stand angle on the IP Phone A Accessory Expansion Module AEM Port Y Z Wheel f Tilt lever EA SB 2 At the back of the IP Phone remove the rubber plug from the AEM port Place the connecting arm of the Expansion Module behind the IP Phone and align the Expansion Module connection plug to the AEM port on the back of the IP Phone 3 Insert the screws in to the top and bottom holes of the connecting arm of the Expansion Module and tighten until snug See Figure 3 Setup and assembly Figure 3 Connecting the Expansion Module Wheel Attachment screws 4 If connecting a second or a third Expansion Module repeat steps 2 to 4
10. nfigured Expansion The Expansion Module display flashes until it Module establishes communication with the IP Phone ealablishes A If the Expansion Module display does not stop communication flashing communication has not been established eo with the IP Phone Check that the Expansion Module is correctly installed and configured Expansion The key labels download to the Expansion Module Module During the download the display is blank downloads key maps Using the wall mount option IP Phone and Expansion Module combination can be wall mounted using the wall mount template provided Setup and assembly Adjusting the tilt base The Expansion Module stand provides a continuous tilt adjustment so the tilt angle matches the IP Phone stand angle while accommodating variations in the desk surface A clamp mechanism is used to unlock and lock the foot stand angle CAUTION Do not over tighten the wheel on the Expansion Module The Expansion Module is tightened by spinning the wheel clockwise and loosened by spinning the wheel counter clockwise Turn the wheel on the back right side if viewed from the front of the Expansion Module to loosen the stand hinge Adjust the angle of the IP Phone using the tilt lever When the IP Phone is set to a preferred angle turn the wheel on the back of the Expansion Module to tighten the stand hinge and lock the stand at the same angle as the attached IP Phone
11. nly use the Connecting cables power cord AC adaptors shipped with the equipment or specified by Nortel to be used with the equipment If you use any other equipment it may cause failures malfunctioning or fire Power cords shipped with this equipment must not be used with any other equipment In case the above guidelines are not followed it may lead to death or severe injury A ze AUMERZEICEARSTH UTDLEITERSTEALN e HT IL BRAK ACPI TIENDE ld b Nm RENTRE WAT MARIE AE AES Rta EEN IND ERE EARD CARNE OTE KRORAERZSCEMHVET e MSN CHIVES HERO BRAK AHORA LIE CCS ERRE KEPARRGEASSRORRESOCEMHBVET Regulatory and safety information Terms you should know Terms you should know Accessory Expansion Module A built in port on an Nortel IP Phone that enables accessory components such as a Expansion Module for IP Phones 1100 Series to connect and communicate with the IP Phone Directory Number DN A one to seven digit number assigned to a system telephone Expansion Module for the IP Phone 1100 Series An accessory for IP Phone 1120E 1140E and 1150E which has 18 physical keys for additional line programmable feature keys 36 where deployed on Nortel Communication Servers supporting the shift function Feature display An area that shows status information about the feature in use It also displays the name and status of the active session Soft keys self labeled A set of keys programmed by your s
12. rademarks of Nortel Networks The Bluetooth word mark and logos are owned by the Bluetooth SIG Inc and any use of such marks by Nortel Networks is under license Other trademarks and trade names are those of their respective owners Publication Number NN43130 101 Document Release Standard 01 02 Date December 2006 Produced in Canada To provide feedback or report a problem in this document go to www nortel com documentfeedback NORTEL
13. rea remains in diagnostic mode until either the user exits the diagnostic more or the idle timeout clears the mode Once cleared the normal display for the current state of the IP Phone is displayed Controls and settings Press the Services key to access the following menu items e Display diagnostics e Set Info Display diagnostics Use the Up Down navigation keys to scroll the Display diagnostics menu to access the following screens diagnostic operations e initial screen Full Contrast LED Test Character Test Initial screen Instructions are displayed on the display area of the IP Phone and the Expansion Module The DN feature key display areas is blank Full Contrast The IP Phone and the Expansion Module display areas are set to maximum dark contrast including the DN feature key areas All LEDs are off LED Test The IP Phone and the Expansion Module LEDs are set to on The display area is cleared including the DN feature key display areas Character Test The IP Phone and the Expansion Module LEDs are set to off The available character set is displayed across all writable areas of the display including the DN feature key display areas The telephone on hook icon is displayed for all DN feature keys Controls and settings Table 2 shows the display diagnostic operation on the IP Phones and the Expansion Module Table 2 Display diagnostic operation on the IP Phone and the Expansion
14. ystem administrator The four keys located directly below the display area have four programmable layers Access the layers through the More key The soft keys are also used to configure parameters in the Telephone Options menu Terms you should know Index A R Accessory Expansion Module Regulatory and safety information AEM 23 19 Auto Dial 23 S D Shift key 16 Directory Number DN 23 Soft keys 23 Display 9 Display label 9 T DN 23 Tilt base 15 F W Feature display 23 Wall mount option 14 Features 8 Initialize the IP Phone KEM 16 Install the IP Phone KEM 10 IP Phone 2002 7 IP Phone 2004 7 IP Phone KEM 7 23 IP Phone KEM controls and set tings 16 IP Phone KEM description 7 IP Phone KEM display 9 IP Phone KEM features 8 L LCD 9 Liquid Crystal Display LCD 9 Nortel Communication Server 1000 Expansion Module for IP Phone 1100 Series User Guide Copyright 2006 Nortel Networks All Rights Reserved The information in this document is subject to change without notice The statements configurations technical data and recommendations in this document are believed to be accurate and reliable but are presented without express or implied warranty Users must take full responsibility for their applications of any products specified in this document The information in this document is proprietary to Nortel Networks Nortel Nortel Logo the Globemark SL 1 Meridian 1 and Succession are t

Download Pdf Manuals

image

Related Search

Related Contents

日立ルームエアコン 取扱説明書    Speco Technologies CVC-6146HR User's Manual  N シ リ ー ズ - 日本アキュムレータ  Festool C12 EC-TEC User's Manual    APPEX user manual  尿定性検査の基礎  Triton RL2000 User Manual  Mod. CP99 compact  

Copyright © All rights reserved.
Failed to retrieve file