Home

Newcon Optik LRB 7X50 Binoculars User Manual

image

Contents

1. 30 Fully multi coated optics 58 72 4 Corresponds to laser direction and approx size of the laser on target 2 Range Finder Type Measuring Range m Accuracy m Resolution m Measurement time sec Meters Y ards display Last 10 readings recall Reticule shape or o Target quality indicator Scan Mode Class 1 eye safe 905nm 20 1 512 1 0 1 Optional Optional Yes Speed Finder LRB 7x50 SPD only 3 Miscellaneous Battery Standard 9v Battery capacity gt 3000 Low Battery Indicator Yes Covering Rubberized Construction Water resistant Tripod thread 1 4 x20 Operational Temperature Range 30 55 C Storage Temperature Range 45 85 C 65 Shock g 5 500 Vibration Hz 210x150x80 Dimensions mm 1 300 Weight kg REC 0 will show instead of REC10 Ifa position is empty then 4 dashes will be displayed After REC 0 the demonstration will restart with REC 1 REC2 and so on 2 If the last measurement was that of speed then the speed will show in REC1 the distance of the vehicle will show in REC2 and so on 3 The self test procedure was completed properly if The square and cross reticle are flashing alternately The lightening power symbol reticle square 7 segment numbers KMH and MPH segments on the screen are visible Y M units of measurement yards or meters 3 KMH MPH units of speed measurement km hour or miles hour 3 Please note onl
2. 10 QUALITY CERTIFICATE The LRB 7X50 LRB 7x50 SPD is suitable for use Production date Serial number Quality Inspector signature Purchase date Salesman Shop stamp Newcon International Itd 1998 2003 Printed in Canada NEWCON OPTIK Operation Manual LRB 7x50 LRB 7x50 SPD LASER RANGE FINDER BINOCULAR In USA 3310 Prospect Ave Cleveland OH 44115 In Canada 1183 Finch Ave W Suite 302 Toronto ON M3J 2G2 Canada IMPORTANT INFORMATION Read prior to activation You have just purchased a complicated electronic device To operate it properly please read this manual carefully Here are some common precautions that must be noted e NEVER subject the unit to impact while operating or being transported e NEVER transport the unit without the case e NEVER disassemble the unit This device contains high voltage components which may be hazardous to you e NEVER reverse the polarity of a battery ALWAYS remove batteries when not in use for long periods of time e ALWAYS store in a warm dry place when not in use 9 CUSTOMER SUPPORT Should you experience any difficulties with your Newcon OPTIK product consult the enclosed manual If the problem remains unresolved contact our customer support department at 416 663 6963 or Toll free at 1 877 398 6666 Our operating hours are 9am 5pm Monday Friday Eastern Standard Time At no time should equipment be sent back to Newco
3. CTION HIGH when the number of 183 Finch Ave W 302 Toronto ON Canada MJ 262 steady received reflected signals is qualified to be enough to This Product complies with CFR 21 1040 10 1040 11 make reliable conclusion about the measured distance E The displayed statistical qualification of the reflected signal Pr a characterizes variation in expected accuracy of measurements At qualification HIGH the accuracy of measurements is stated as a ne 1 Eyepieces 9 Interpupilary distance adjustment lever 1m or 0 1 At lower rates of statistical qualification the 10 Identification Label Located on the Bottom expected accuracy may marginally degrade Please note this is an optional feature Fig 2 The display presents message LOW BAT when voltage of the primary 9 volt battery drops below 7 2 volt At this point the 3 SUPPLIED ACCESSORIES System is still functional but the battery should be replaced as soon as possible The system can operate at the voltage levels LRB 7X50 is supplied in the following assembly bove 7 volt above 7 volts z ais Case The System remains in the active displaying state for 10 seconds Neck Strap after pressing of any of the operating buttons and after 10 seconds User s manual enters the passive low power state Warranty card Alkaline or lithium type of batteries capable to sustain current 9V battery optional f drain up to 150 ma should be used for powering the S
4. H or Degrees 4 Measurement Result 5 Target Quality Indicator optional 6 Laser Active Indicator Fig 3 5 1 Preparing the Device for Operation e Unbolt a screw and open battery compartment cover at the bottom of the device e Insert one 9V battery sold separately into the battery compartment observing correct polarity e Close up the battery compartment cover tighten the screw After changing the battery it is recommended to run the CL CLEAR mode refer mode selection procedure e Take off lens caps e Look through the eyepieces 1 fig 1 e Adjust interpupilary distance by turning lever 9 fig 2 until two images converge into one e Make dioptric correction individually for each eye by rotating rubber rings 4 fig 2 of each eyepiece Now your unit is ready for operation as a conventional 7x binocular passive state 5 2 Distance Measuring Procedure a Measuring state When the Rangefinder is in the passive low power state the LCD Display is blank transparent Pressing any of the operating buttons activates the System and the Display Initially the System always assumes READY mode of operation and word READY appears on the Display Pressing Action button 6 fig 1 at this point triggers a distance measuring session and the result will be displayed in numerical form 4 fig 3 if measurement is unsuccessful then four dashes will appear in the numerical area Please note that the targe
5. a NEWCON Authorized Service Postage insurance or shipping costs incurred in presenting your NEWCON product for warranty service are your responsibility Please include a check or money order made out to NEWCON OPTIK for the amount of 15 00 to cover shipping and handling This covers products shipped in USA or Canada only Features of the LRB 7X50 Laser Range Finder Binocular e Latest digital circuitry allows targeting through most types of glass Last Target measurement Meters Yards display Last 10 readings recall Selectable reticule shape or o Target quality indicator Speed Finder On LRB 7x50 SPD only CONTENTS Brief description Appearance of the device Supplied accessories Technical characteristics Gin es Ar Me Operation instructions 5 1 Preparing the device for operation 5 2 Distance measuring procedure Storage and maintenance instructions Trouble shooting Warranty Customer Support 10 Quality certificate Oo 9 ND BEFORE USE CAREFULLY READ ALL THE INSTRUCTIONS FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANTY 1 BRIEF DESCRIPTION LRB 7X50 SPD Laser Range Finder Binocular is an advanced Laser Range Finder system that provides instant distance measurements consistently and accurately The stereoscopic device provides convenient observation with both eyes The user can measure the distance to an object without loosing sight of the target Therefore the LRB 7X50 SPD substitute
6. either your hand nor finger is blocking objective lenses Laser emitting lens or Receiver lens e Check if the unit is steady while pressing Action button 6 STORAGE AND MAINTENANCE INSTRUCTIONS a a 2 APPEARANCE OF THE DEVICE Precautions LRB 7X50 SPD is a sophisticated precision es ss Se optical instrument equipped with electronics Therefore it should be handled with due care e Keep your device away from direct sunlight impact dust moisture and sudden changes of temperature e Do not touch the optical surfaces with fingers Doing so may damage the anti reflection coating e Avoid shocks and sharp jolts e Clean optical surfaces with professional camera lens cleaning supplies e To clean the exterior of the device use a soft clean cloth e Keep away from heating appliances and central heating e Remove the batteries when storing the device for long 2 period of time e Do not apply unnecessary force to the lens assembly agile elements and thread connections e Only the manufacturer should perform repair work _1 Eyepieces 2 Objective Lens Emitting Lens 3 Objective Lens Receiver Lens 4 Dioptric Correction Ring 5 Mode Button 6 Action Button 7 Body of the Device 8 Rubber Grip Fig 1 e TARGET REFLECTION MED when the number of steady received reflected signals is in medium range and enough to make positive conclusion about the measured distance a a e TARGET REFLE
7. n without following the instructions of our technical support department Newcon accepts no responsibility for unauthorized returns To locate NEWCON Authorized Dealer call Tel 416 663 6963 Fax 416 663 9065 Email NEWCONSALES NEWCON OPTIK COM INTERNET http WWW NEWCON OPTIK COM The defective products should be shipped to In USA 3310 Prospect Ave Cleveland OH 44115 In Canada 1183 Finch Ave W Suite 302 Toronto ON M3J 2G2 International 1183 Finch Ave W Suite 302 Toronto ON M3J 2G2 CANADA 8 WARRANTY NEWCON OPTIK warrants this product against defects in material and workmanship for one year from the date of the original date of consumer s purchase but no more than 18 months from the date of manufacturing Should your Newcon product prove defective during this period please bring the product securely packaged in its original container or an equivalent along with proof of the date of original purchase to your Newcon Dealer Newcon will repair or at its option replace the product or part thereof which on inspection by Newcon is found to be defective in materials or workmanship What This Warranty Does Not Cover NEWCON is not responsible for warranty service should the product fail to be properly maintained or fail to function properly as a result of misuse abuse improper installation neglect damage caused by disasters such as fire flood lightning improper electrical current or service other than by
8. s a need for two separate devices binocular and range finder combining both requirements in a single device The outstanding optics provide a sharp clear image under all conditions LRB 7X50 SPD is utilizing a revolutionary digital design which is outperforming any other product in its class and price range The unit sends invisible eye safe laser beam pulses to the target The returned beams are captured by the digital circuitry The time differential allows us to calculate the distance to the target 7 TROUBLE SHOOTING The range measuring mode does not work Press the Action Button again Check that the batteries are installed properly Check the charge of the batteries Replace if they are weak How can I clear last reading before making next measurement Direct the unit s LCD reticle at the new target press the Action button The new reading will appear There are black dots in the image A LCD Liquid Crystal Display is installed in the optical channels of the device Due to manufacturing imperfections in the production process of the LCD small black dots scratches and other blemishes might be visible Those blemishes are strictly regulated for maximum allowed number size and location It does not degrade the product s performance Range measurement cannot be obtained e Check if range detection mode is activated message READY appears on the LCD display e Check if Active Button is pressed e Make sure that n
9. t must be over 20m away If the Action button 6 is held pressed for more than 3 seconds the System automatically enters SCANNING mode This feature is not available on all versions At this mode the System repetitively performs distance measuring and displaying The time interval between measurements is approximately 1 second The maximum measuring range for most objects will be 1512m The maximum measured distance will vary greatly depending on the reflectivity of the target weather conditions and more Target reflectivity depends on its color surface finish shape etc Bright colors are more reflective than darks A polished surface is more reflective than a rough one Larger targets are easier for distance measuring Measuring a target faced at 90 perpendicular to the laser beams path provides optimal results Bad weather conditions rain fog snow mist will reduce the maximum measured range Bright sunny days will reduce performance as well While the unit will work through many glass types measuring through glass will affect the results
10. y on LRB 7x50 SPD Shape of the reticle cross shape or rectangular shape 2 Please note this is an optional feature rEC1 recall function Upon pressing the Action button 6 fig 1 the Display will sequentially show results of last 10 measurements starting from the latest one The number appearing after word REC shows the number of the measurement counted back in the sequence When the System is in inactive state the 10 previous measurements are stored within the System and may be recalled any time 5 2 6 Mode Selection State Correct Order of Modes LRB 7x50 LRB 7x50 SPD Y MPH M KMH REC Y CLR M SELFTEST REC CLR 1 REC1 shows the value of the last measurement REC 2 the previous measurement and so on b Mode selection state Pressing MODE button 5 fig 1 when the System is in READY mode brings the System to the Mode selecting state Pressing the Mode button can sequentially scan the Modes The Mode under selection is being indicated on the Display by flashing of the selectable feature The flashing feature can be selected by pressing the Action button 6 The System operates in the setting Modes which are displayed as follows refer to fig 3 5 OPERATION INSTRUCTIONS Liquid Crystal Display LCD 1 Low Battery Indicator 2 Reticule cross or rectangular selectable 3 Units of Measurement Yards Meters KMH MP
11. ystem CL clear data function upon pressing the Action button 6 fig 1 the entire data on all previous measurements will be erased NOTE After changing a battery the recall stack should be cleared by exercising the CL mode OVER 100 allows to ignore targets closer than 100m Useful when looking through bush Please note this is an optional feature on early designs Latest version includes automatic Last Target selection that renders obsolete the requirement for a separate manual mode selection c Reflection Distance measuring procedure includes instant statistical processing of the package of single measuring sessions Qualitative result of the statistical processing is presented on the Display as a message TARGET REFLECTION 5 There are four statistical qualifications of the reflected signal e NO TARGET REFLECTION when a reflected signal isn t received Numerical display shows 4 dashes in the distance displaying area e TARGET REFLECTION LOW when the number of steady received reflected signals is just enough to make acceptable conclusion about the distance 4 TECHNICAL CHARACTERISTICS 1 Optics Observation Magnification x Objective Lens mm Exit Pupil Diameter mm Eye Relief mm Field of View Axial Resolution Image tilt maximum Horizontal Vertical Type of coating Interpupillary Distance mm Diopter Adjustment range Reticule Binocular 7 50 7 1 25 5 6 60

Download Pdf Manuals

image

Related Search

Related Contents

Samsung 29"-os ultrawide prémium kategóriás ívelt monitor  Tripp Lite SmartOnline 240/120V or 208/120V 12kVA 8.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 8U, USB, DB9 Serial, Hardwire  USER`S MANUAL  Trane Voyager 12.5 to 25 Tons Brochure    MLNX_EN for Linux User Manual  e4ride electric skateboard - user manual  New Buck Corporation CR8T User's Manual  View User`s Manual [US] - Acoustic Amplification  Smartline RI Detector 2300 / 2400 user manual  

Copyright © All rights reserved.
Failed to retrieve file