1. on the two disconnected wires in the lower switch housing Install the switch housing cap and plug button to the lower switch housing Once you have uninstalled the light fixture continue with step 7 6 Steps 7 17 7 20 Male Dummy Terminal Female Dummy Terminal Plug Button _ Step 7 22 13 42856 01 01 30 09 Hunter Fan Company 8 1 8 2 8 3 8 4 8 5 8 Operating and Cleaning Your Ceiling Fan Turn on electrical power to the fan The fan pull chain controls power to the fan The pull chain has four settings in sequence High Medium Low and Off e Pull the chain slowly to change settings e Release slowly to prevent the chain from recoiling into the blades e The chain uses a breakaway connector that separates if the chain is jerked If this happens simply reinsert the chain into the connector The light pull chain controls the power to the light fixture The chain has two settings ON and OFF Ceiling fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can
2. green ground wire grounding from the fan Single Switch Wiring 4 4 Connect the white wire grounded from the ceiling to the white k wire grounded from the fan 4 5 Connect the remaining wires as follows Dual Switch Wiring i e The black wire ungrounded from the ceiling to the black wire ungrounded from the fan e The black white wire ungrounded from the fan to the wire ungrounded for the wall switch Single Switch Wiring e The black wire ungrounded from the ceiling to the black ungrounded and the black white wire ungrounded from the fan A CAUTION Be sure no bare wire or wire strands are visible after making connections 4 6 Turn the splices upward and push them carefully back through the ceiling plate into the outlet box 4 7 Spread the wires apart with the grounded wires on one side of the outlet box and the ungrounded wires on the other side of the outlet box 7 42856 01 01 30 09 Hunter Fan Company 5 e Installing the Motor Housing 5 1 Place the fan housing over the motor 5 2 Raise the trim ring to allow access to the holes on the ceiling plate Note Let the trim ring rest sitting diagonally on ceiling plate 5 3 5 4 5 5 to keep the trim ring out of the way while installing the canopy screws Align the holes in the fan housing with the holes in the ceiling plate Partially install each canopy screw into the h
3. For Your Records and Warranty Assistance For reference also attach your receipt or a copy of your receipt to the manual Form 42856 01 20090130 2009 Hunter Fan Co Type A Models Owner s Guide and Installation Manual SINCE 1886 Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS e Use only Hunter replacement parts e To reduce the risk of personal injury attach the fan directly to the Table Of Contents support structure of the building according to these instructions and use only the hardware supplied To avoid possible electrical shock before installing your fan 2 Installing the Hanger Bracket disconnect the power by turning off the circuit breakers to the 3 Assembling and Hanging the Fan 6 outlet box and associated wall switch location If you cannot lock the circuit break
4. ach product For quiet and optimum performance of your Hunter fan use only Hunter speed controls Low Profile Mounting fits close to the ceiling recommended for ceilings less A CAUTION To reduce the risk of than 8 feet high personal injury attach the fan directly to the support structure of the building according to these instructions and use only the hardware supplied 3 42856 01 01 30 09 Hunter Fan Company l Getting Ready To install a ceiling fan be sure you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 Preparing the Fan Site Before you begin installin
5. chain through the hole in the center of the glass For Light Bulbs bowl Thread the light pull chain through the hole in the center of the glass bowl Then Thread the light pull chain through the hole in the center of the cover plate Metal Disk Thread the fan pull chain through the grommet hole in the side of the cover plate Metai Rod Place the cover plate up against m the glass bowl Align the holes in the cover plate and glass bowl Thread the light pull chain Glass Bowl through the finial and screw the finial onto the threaded rod end until tight Cover Plate Reattach the fandangle to the extra pull chain Finial 12 42856 01 01 30 09 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Uninstalling the Light Fixture 7 17 To uninstall the light fixture first disconnect the plug connectors between the black wire and the red wire Disconnect the plug connectors between the two white wires Remove the two screws attaching the light kit to the lower switch housing Lower Switch Remove the light fixture from the lower switch housing Housing pulling disconnected wires through the hole in the center of the lower switch housing Note When removing the wires pull the thin plug connector male through first and then pull the other plug connector female through the hole Install the dummy terminals included in the sack parts
6. ers in the off position securely fasten a prominent warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical 6 Assembling the Blades codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician To reduce the risk of personal injury do not bend the blade attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a solid state speed control with this fan Use only Hunter speed controls 1 e Getting Ready 4 Wiring the Fan 5 Installing the Motor Housing 7 Completing Your Installation With or Without a Bowl Light Fixture 8 Operating and Cleaning Your Ceiling 9 e Troubleshooting 2009 Hunter Fan Company 2 42856 01 01 30 09 Hunter Fan Company Mounting and Optional Accessories Vy Vy Understanding Mounting Hunter s patented mounting system provides you maximum ease in installing your fan This fan was designed to be mounted only on flat ceilings and can be used on ceilings less than 8 feet high Considering Optional Accessories Low Profile at Mounting Style Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with e
7. g plate into the Ceiling pilot holes you drilled Plate Steps 2 4 2 6 Tighten the screws into the 9 64 pilot holes do not use lubricants on the screws Do not over tighten Flat Washer 3 Wood Screw a FENUNUNEEUOUUNUNE be 5 42856 01 01 30 09 Hunter Fan Company 3 Assembling and Hanging the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 3 1 Lift the motor assembly and hook the three tabs over the handles one at a time 6 42856 01 01 30 09 Hunter Fan Company 4 Wiring the Fan All wiring must be in accordance with national and local electrical i Iri ego e e o 4 Dual Switch Wiring codes and ANSI NFPA 70 If you are unfamiliar with wiring use a 1 z H qualified electrician 5 Wall switches are not included Select an acceptable general use switch p in accordance with national and local electrical codes g gt amp 9 4 1 Before attempting installation make sure the power is still off 4 2 To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight For all these connections use the wire connectors provided 4 3 Connect the bare or green ground wire grounding from the ceiling to the green ground wire grounding from the ceiling plate and the
8. g the fan follow all the instructions in the pullout sheet called Preparing the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings 4 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in sets as they were shipped 42856 01 01 30 09 Hunter Fan Company 2 Installing the Hanger Bracket A CAUTION To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel AA 2 1 Drill two pilot holes into the wood support structure through the outermost holes in the outlet box The pilot holes should be 9 64 S FAA in diameter TS fies 2 2 Place the trim ring over the ceiling plate sam 4 gt 2 3 Thread the lead wires from the outlet box down through the hole in the middle of the ceiling plate 2 3 Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure a 2 4 Place a flat washer on each of the two 3 wood screws and pass Pa the screws through the slotted holes in the ceilin
9. ight fixture assembly and an optional switch housing cap and plug button This feature gives you the option of installing the fan with OR without the included light fixture The steps below direct you whether or not you are installing a light fixture A WARNING Use only the light fixture supplied with this fan model 7 1 To attach the upper switch housing partially install two housing assembly screws into the switch housing mounting plate 7 2 Feed the upper plug connector through the center opening of the housing 7 3 Align the keyhole slots in the housing with the housing assembly screws Steps 7 1 7 3 Housing 7 4 Turn the housing counterclockwise until the housing assembly Assembly Apa screws are firmly situated in the narrow end of the keyhole slots Screw a P Install the remaining screw into the housing Tighten all three screws firmly A CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate Failure to properly attach and tighten all three assembly screws could result in the switch housing and light fixture falling 7 5 If you want to install the light fixture proceed with step 7 6 now If you do not want to install the light fixture you need to uninstall it now See Uninstalling the Light Fixture on step 7 17 Once you have uninstalled the light fixture continue with step 7 6 10 42856 01 01 30 09 Hunter Fan Company 7 C
10. oles in the fan housing and into the ceiling plate until all holes are aligned Securely tighten all screws Lower the trim ring on the ceiling plate to cover the canopy screws that were installed in the previous step 8 i Trim Ring Ceiling Plate PONSING Steps 5 1 5 3 Canopy Screw 42856 01 01 30 09 Hunter Fan Company 6 Assembling the Blades Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 6 1 Your fan may include blade grommets If your fan has grommets Step 6 1 Detail insert them by hand into the holes on the blades 6 2 Attach each blade to a blade iron using three blade assembly screws If you used grommets the blades may appear slightly loose after screws are tightened This is normal 6 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to secure shipping blocks 6 4 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Blade Assembly Use with grommet ews Use without grommet Blade Mounting Screw 42856 01 01 30 09 Hunter Fan Company 7 Completing Your Installation With or Without a Bowl Light Fixture Your Hunter fan comes with an integrated l
11. ompleting Your Installation With or Without a Bowl Light Fixture Continued 7 6 To attach the lower switch housing connect the upper plug 7 7 connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing to the upper switch housing with three housing assembly screws lI 42856 01 01 30 09 Hunter Fan Company Plug Connector A Steps 7 6 7 7 Lower Switch Housing Plug T Connector Detail Housing Assembly Screw 7 Completing Your Installation With or Without a Bowl Light Fixture Continued Installing the Glass Bowl 7 8 First install included B10 60 Watts Maximum bulbs into the sockets 7 9 Ifthe fandangle is attached to the extra pull chain remove it now Attach the extra pull chain included to the fan pull chain using Breakaway the plastic breakaway connector You may find the plastic Connector breakaway connector on the end of the extra chain Thread the fan pull chain through the hole in the metal disc Then thread the fan pull
12. remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish Clean wood finish blades with a furniture polishing cloth Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades in the same manner as the fan finish To Change Airflow Direction Turn the fan off and let it come to a complete stop Slide the reversing switch on the fan to the opposite position Restart fan 42856 01 01 30 09 Hunter Fan Company Reversing Switch 14 gt In warm weather use downward air flow pattern In cold weather use upward air flow pattern 9 Troubleshooting Problem Nothing happens fan does not move 1 Turn power on replace fuse or reset breaker 2 Loosen canopy check all connections according to the wiring the fan section 3 Check the plug connection in the switch housing 4 Push motor reversing switch firmly left or right to ensure that the switch is engaged 5 Pull the pull chain to ensure it is on 6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade bracket screws until snug 2 Tighten the blade screws until snug 3 Check to see if the blade is cracked If so replace all the blades 4 Change to an appro
13. ved speed control 5 Be sure that the glass is secure 6 Check and tighten the screws in the switch housing mounting plate and in the upper and lower switch housing Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade and or blade iron screws Problem Lights dim when turned on or do not turn on 1 Check to make sure wattage of light bulbs installed match the specifications on the light socket If you need parts or service assistance please call 888 830 1326 or visit us at our Web site at http www hunterfan com Hunter Fan Company 7130 Goodlett Farms Pkwy Memphis Tennessee 38016 42856 01 01 30 09 Hunter Fan Company