Home
        Hunter Fan 42654-01 Fan User Manual
         Contents
1.      3    Wood  Screw    eee FU VUEUUUNUEEEEDD OU Nias       7  42654 01   03 08 10    Hunter Fan Company                Toward  Ceiling Peak    For Angled Ceilings  Be sure to orient  the ceiling plate so that the two tabs  are pointing toward the ceiling peak              Steps 2 3   2 6             3    Assembling and Hanging the Fan       A WARNING  Fan may fall if not assembled as directed in these  installation instructions    3 1  Unbundle the wires from the fan    For Standard or Angled mounting     3 2  Insert the downrod through the canopy and canopy trim ring   Feed the wires from the fan through the downrod on one side of  the pin in the ball     3 3  Loosen the square head set screw on the adapter to install the  pipe and ball assembly  Note  When the pipe and ball assembly  is fully installed  2 3 threads on the pipe will still be visible  this is  normal  Securely retighten the set screw with a wrench or pliers   Skip to step 3 7     A CAUTION  The adapter has a special coating on the threads  Do  not remove this coating  the coating prevents the downrod from  unscrewing  Once assembled  do not remove the downrod    For Low Profile mounting     Note  For low profile mounting  the downrod is replaced with the  low profile washer     3 4  Remove the set screw from the adapter   3 5  Place the low profile washer into the canopy with the lip down     3 6  Align the holes in the washer with the holes in the adapter   Assemble securely with three low profile screws  
2.    2   Installing the Ceiling Plate    A CAUTION  To avoid possible electrical shock  before installing your fan     disconnect the power by turning off the circuit breakers to the outlet box    and associated wall switch location  If you cannot lock the circuit breakers    in the off position  securely fasten a prominent warning device  such as a    tag  to the service panel     2 1     2 2     2 3     2 4     2 5     2 6     Drill two pilot holes into the wood support structure through the  outermost holes in the outlet box  The pilot holes should be 9 64     in diameter     For Angled Ceilings  Be sure to orient the ceiling plate so that the  two tabs are pointing toward the ceiling peak     Your fan comes with four preinstalled noise isolators  Check to  make sure all four isolators are in place and were not removed  during shipment     Place a flat washer on each of the two 3    wood screws     Thread the supply wires from the outlet box in the ceiling through  the hole in the center of the ceiling plate     Align the slotted holes in the ceiling plate with the pilot holes you  drilled in the wood support structure  For proper alignment use  slotted holes directly across from each other     Note  The isolators should be flush against the ceiling     Pass the screws through the slotted holes in the ceiling plate into  the pilot holes you drilled     Tighten the screws into the 9 64    pilot holes  do not use lubricants  on the screws  Do not over tighten     Flat Washer  
3.    For Your Records and P      Warranty Assistance AYA O e 2      S  For reference  also attach your receipt or a copy J j  lt  uD  E    F  Ba NE AT    of your receipt to the manual       Owner   s Guide and Installation Manual     TI  zR   0    gt    ra   Q    74               SINCE 1886       a        Form  42654 01  20100308    2010 Hunter Fan Co           Welcome       Your new Hunter   ceiling fan is an addition to your home or office that  will provide comfort and performance for many years  This installation  and operation manual gives you complete instructions for installing  and operating your fan     We are proud of our work  We appreciate the opportunity to supply  you with the best ceiling fan available anywhere in the world     Before installing your fan  for your records and warranty assistance   record information from the carton and Hunter nameplate label   located on the top of the fan motor housing      Cautions and Warnings    e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING  INSTALLATION  SAVE THESE INSTRUCTIONS   Table Of Contents e Use only Hunter replacement parts   e To reduce the risk of personal injury  attach the fan directly to the  support structure of the building according to these instructions   2   Installing the Ceiling Plate and use only the hardware supplied   To avoid possible electrical shock  before installing your fan   disconnect the power by turning off the circuit breakers to the  outlet box and associated wall switch location  I
4.    Hanging the Fan     Note  To hang the fan  you must tilt the canopy to an almost vertical  position so that the canopy slots sit on the ceiling plate hooks     3 7  Raise the fan and align the slots in the canopy with the hooks on  the ceiling plate     3 8  Place the slots over the hooks to hang the fan     8    Standard or Angled Mounting             Steps 3 2   3 3    9 mm  Downrod            lt  Canopy        lt  Canopy  Trim Ring       Set Screw     d                      Low Profile Mounting          Steps 3 5   3 6 Low Profile Screws         E T Fa nA  Ground aster  Wire  Canopy    Trim Ring a    in                Low Profile Screw          Step 3 6  Detail     Adapter Low Profile Screw         Low Profile  Washer             42654 01   03 08 10    Hunter Fan Company                4   Securing Fan to Secondary Support System       4 1     4 2     4 3     4 4     4 6     4 7   4 8     Find the looped end of the braided cable and insert it through the  ceiling plate and one of the holes in the outlet box into the ceiling     Access the support brace in the ceiling  You may not be able to do  this from below the ceiling depending on your installation site     Drive a wood screw and washer into the side of the brace that  holds the outlet box  Leave 3mm  1 8     of space between the  support brace and the washer     Wrap the braided cable around the support brace once creating a  complete circle       Hook the looped end of the cable over the wood screw so that the    
5.    To install a ceiling fan  be sure you can do the following   e Locate the ceiling joist or other suitable support in ceiling   e Drill holes for and install wood screws   e Identify and connect electrical wires   e Lift 40 pounds     If you need help installing the fan  your Hunter fan dealer can direct  you to a licensed installer or electrician     Gathering the Tools  You will need the following tools for installing the fan   e Electric drill with 9 64    bit  e Standard screwdriver  magnetic tip recommended   e Phillips head screwdriver  magnetic tip recommended   e Wrench or pliers    e Ladder  height dependent upon installation site     Checking Your Fan Parts    Carefully unpack your fan to avoid damage to the fan parts  Refer to  the included Parts Guide  Check for any shipping damage to the motor  or fan blades  If any parts are missing or damaged  contact your Hunter  dealer or call Hunter Technical Support Department at 866 268 1936     Preparing the Fan Site    Before you begin installing the fan  follow all the instructions in   the pullout sheet called    Preparing the Fan Site     Proper ceiling fan  location and attachment to the building structure are essential for  safety  reliable operation  maximum efficiency  and energy savings     6    Installing Multiple Fans   If you are installing more than    one fan  keep the fan blades and  blade irons  if applicable  in sets   as they were shipped        42654 01   03 08 10    Hunter Fan Company    K2          
6.   To attach the lower switch housing  connect the upper plug  connector from the motor to the lower plug connector in the  lower switch housing assembly     Note  Both plug connectors are polarized and will only fit together  one way  Make sure the connectors are properly aligned before  connecting them  Incorrect connection could cause improper  operation and damage to the product       Place the lower switch housing assembly over the upper switch  housing  Align the side screw holes in the upper and lower switch  housings  Attach the lower switch housing to the upper switch  housing with three  6 32 x 3 8    housing assembly screws        Housing  Assembly Screw          Step 8 4    N    Plug  Connector  Detail                   13  42654 01    03 08 10    Hunter Fan Company                  8 e Completing Your Installation With a Multi Staked Light Fixture  Continued     8 6  To install each shade  first loosen the three thumbscrews     8 7  Raise the shade to the light fixture  Tighten the thumbscrews  securely     8 8  Install B10 candelabra base light bulbs  60 Watt maximum each      Note  Glass shade style and number of lights may vary        Thumbscrews    Steps 8 7   8 8             Note  In compliance with Canadian federal energy regulations  this  ceiling fan contains a device that restricts the light kit to a  maximum of 190 Watts  Exceeding that limit or the marked    limit on this product may result in fire hazard or improper  operation        14  42654 01   03 
7.  Remove the blade mounting screws and rubber shipping bumpers  from the motor  Note  Some blade mounting screws are installed  in the motor to secure shipping blocks     7 4  For each blade  insert one blade mounting screw through the  blade iron  and attach lightly to the fan  Insert the second blade  mounting screw  then securely tighten both mounting screws        Blade Assembly    Use with grommet screws       Use without grommet    Blade  Mounting  Screw       12  42654 01   03 08 10    Hunter Fan Company                      Steps 8 1   8 3    8 e Completing Your Installation With a Multi Staked Light Fixture          A WARNING  Use only the light fixture supplied with this fan model     8 1  To attach the upper switch housing  partially install two  6 32 x  3 8    housing assembly screws into the switch housing mounting  plate     8 2  Align the keyhole slots in the housing with the housing assembly  screws     8 3  Turn the housing counterclockwise until the housing assembly  screws are firmly situated in the narrow end of the keyhole slots   Install the remaining  6 32 x 3 8    screw into the housing  Tighten  all three screws firmly     A CAUTION  Make sure the upper switch housing is securely attached  to the switch housing mounting plate  Failure to properly attach and  tighten all three assembly screws could result in the switch housing           l     Plug  Connector    Lower  Switch  Housing          Housin  N Upper fixture falling   Screw Switch    Housing 8 4
8.  remain engaged while  swinging the canopy for alignment       Holding the canopy up with the screw holes aligned  partially    install two canopy screws into the holes opposite the ceiling plate  tabs    Partially install a canopy screw between the slots in the canopy   When all the holes are properly aligned  securely tighten all three  canopy screws    Verify that the tabs in the canopy are still in the grooves of the  hanger ball       Align the tabs on the trim ring opposite the grooves in the hanger    ball  Using both hands  push the canopy trim ring up to the top of  the canopy  The canopy trim ring will snap and lock into place   Note  Should you need to remove the trim ring  press firmly on  opposite sides of the trim ring directly above the groove in the  hanger ball  The tabs will flex out releasing the canopy trim ring        Step 6 1       Step 6 2             Step 6 3       Canopy     gt     Canopy  Trim                                 Canopy Screw    lI    42654 01   03 08 10    Hunter Fan Company                   7    Assembling the Blades    Hunter fans use several styles of fan blade irons  brackets that hold the  blade to the fan      7 1  Your fan may include blade grommets  If your fan has grommets  Step 7 1  Detail   insert them by hand into the holes on the blades     7 2  Attach each blade to a blade iron using three blade assembly  screws  If you used grommets  the blades may appear slightly loose  after screws are tightened  This is normal     7 3 
9. 08 10    Hunter Fan Company    K2             9 1        9   Operating and Cleaning Your Ceiling Fan    Turn on electrical power to the fan     9 2  The fan pull chain controls power to the fan  The pull chain has  four settings in sequence  High  Medium  Low and Off     Fa     9 4     9 5     e Pull the chain slowly to change settings     e Release slowly to prevent the chain from recoiling into the    blades     e The chain uses a breakaway connector that separates if the    chain is jerked  If this happens  simply reinsert the chain into    the connector     Ceiling fans work best by blowing air downward  counterclockwise    blade rotation  in warm weather to cool the room with a direct    breeze  In winter  having the fan draw air upward  clockwise blade    rotation  will distribute the warmer air trapped at the ceiling    around the room without causing a draft     For cleaning finishes  use a soft brush or lint free cloth to prevent    scratching  A vacuum cleaner brush nozzle can remove heavier    dust  Remove surface smudges or accumulated dirt and dust using    a mild detergent and a slightly dampened cloth  You may use  an artistic agent  but never abrasive cleaning agents as they will    damage the finish     Clean wood finish blades with a furniture polishing cloth   Occasionally  apply a light coat of furniture polish for added    protection and beauty  Clean painted and high gloss blades in the    same manner as the fan finish     To Change Airflow Direction    
10. Turn the fan off and let it come to a complete  stop  Slide the reversing switch on the fan to the    opposite position  Restart fan        42654 01   03 08 10    Hunter Fan Company    a       J    Reversing  Switch       In warm weather  use  downward air flow pattern       In cold weather  use upward  air flow pattern                      10   Troubleshooting    Problem  Nothing happens  fan does not move   1  Turn power on  replace fuse  or reset breaker    2  Loosen canopy  check all connections according to the wiring the  fan section    3  Check the plug connection in the switch housing    4  Push motor reversing switch firmly left or right to ensure that the  switch is engaged    5  Pull the pull chain to ensure it is on    6  Remove the shipping bumpers     Problem  Noisy operation    1  Tighten the blade assembly screws and blade iron armature screws  until snug     2  Check to see if the blade is cracked  If so  replace all the blades     Problem  Excessive wobbling    1  If your fan wobbles when operating  use the enclosed balancing kit  and instructions to balance the fan     2  Tighten all blade iron screws     3  Turn power off  support fan very carefully  and check that the  hanger ball is properly seated     Problem  Lights turn off when installed or dim when turned on  1  Check to make sure the wattage and type of light bulbs installed  match the specifications on the light socket   Problem  Lights shut off suddenly  1  Turn the power to the fan off at the wa
11. braided cable lies between the washer and the support brace     Tighten the loop and secure the screw and washer all the way  down to the support brace     Coil up the excess cable     Return to the fan so you can complete the fan wiring           Steps 4 2   4 3 3mm 1 8      Support    Ceiling       Steps 4 4   4 5       _   o     lt          Brace    Outlet Box                                        or  C       m                9    42654 01   03 08 10    Hunter Fan Company                   5    Wiring the Fan    All wiring must be in accordance with national and local electrical  codes and ANSI NFPA 70 1999  If you are unfamiliar with wiring     use a qualified electrician  Wire  Connector       Wall switches are not included  Select an acceptable general use switch  in accordance with national and local electrical codes     5 1  Before attempting installation  make sure the power is still off     5 2  To connect the wires  hold the bare metal leads together and place  a wire connector over them  then twist clockwise until tight  For                      all these connections use the wire connectors provided  es    Dual Switch Wiring  5 3  Connect the bare or green ground wire  grounded  from the x y ye      2 I N  ceiling to the green ground wire  grounded  from the ceiling plate  and the green ground wire from the fan    it                     5 4  Connect the white wire  ungrounded  from the ceiling to the  white wire  ungrounded  from the fan        5 5  Connect the r
12. emaining wires as follows     Dual Switch Wiring     il    e The black wire  ungrounded  from the ceiling to the black wire   ungrounded  from the fan    e The black white wire  ungrounded  from the fan to the wire   ungrounded  for the wall switch                      Single Switch Wiring  Single Switch Wiring       Wo             s      e The black wire  ungrounded  from the ceiling to the black   ungrounded  and the black white wire  ungrounded  from    the fan    SS  e       nem                       A CAUTION  Be sure no bare wire or wire strands are visible after  making connections        5 6  Turn the splices upward and push them carefully back through the  ceiling plate into the outlet box        i    5 7  Spread the wires apart  with the grounded wires on one side of  the outlet box and the ungrounded wires on the other side of the  outlet box                 10  42654 01   03 08 10    Hunter Fan Company                   6   Installing the Canopy and Canopy Trim Ring    A WARNING  Failure to complete the following steps could cause the fan  to fall     Note  It is recommended you use a magnetic tip screwdriver for the  following steps     6 1     6 2     6 4     6 5     Rotate the hanger ball so the tab in the canopy is secure in the  hanger ball groove  Note  Your fan may have multiple tabs and  grooves that must be aligned     Swing the fan up to align the canopy screw holes with the  mounting holes on the ceiling plate     A WARNING  The slots in the canopy must
13. f you cannot lock  the circuit breakers in the off position  securely fasten a prominent  warning device  such as a tag  to the service panel   All wiring must be in accordance with national and local electrical    1    Getting Ready    3 e Assembling and Hanging the Fan    8    4 e Securing Fan to Secondary Support    6    Installing the Canopy and Canopy    PM codes and ANSI NFPA 70  If you are unfamiliar with wiring  use a  7   Assembling the Blades qualified electrician   8 e Completing Your Installation With a e To reduce the risk of personal injury  do not bend the blade   Multi Staked Light Fixture attachment system when installing  balancing  or cleaning the fan   9   Operating and Cleaning Your Ceiling Never insert foreign objects between rotating fan blades     To reduce the risk of fire  electrical shock  or motor damage  do not  use a Solid state speed control with this fan  Use only Hunter speed  controls           2010 Hunter Fan Company  2  42654 01     03 08 10    Hunter Fan Company                   Preparing the Fan Site    Step 1   Choose the Fan Site    Proper ceiling fan location and attachment to the building  structure are essential for safety  reliable operation  maximum  efficiency  and energy savings     Choose a fan site where     e No object can come in contact with the rotating fan blades during  normal operation     e The fan blades are at least 7 feet above the floor and the ceiling is  at least 8 feet high     e The fan blades have no obstructi
14. let box    4 4  Attach the outlet box directly to the support brace or joist with two  8 x 1 1 2     wood screws and washers  Th e bottom of the outlet box must be recessed a  minimum of 1 16    into the ceiling     Step 5   Prepare the Wiring    5 1  Make sure the circuit breakers to the fan supply line leads and associated wall  switch location are turned off   If you cannot lock the circuit breakers in the  off position  securely fasten a prominent warning device  such as a tag  to the  service panel    5 2  Thread the fan supply line through the outlet box so that the fan supply line  extends at least 6    beyond the box    5 3  Attach the fan supply line to the outlet box with an approved connector   available at any hardware store or electrical supply house    5 4  Make certain the wiring meets all national and local standards and ANSI NFPA  70    You have now successfully prepared your ceiling fan site  For instructions to install   your ceiling fan  go to your fan manual and continue with Section 2    Installing the   Ceiling Plate     J  42654 01   03 08 10    Hunter Fan Company                               A CAUTION  All wiring must be in    accordance with national and local  electrical codes and ANSI NFPA 70  If  you are unfamiliar with wiring  use a    qualified electrician        Installer   s Choice and Optional Accessories             Understanding Mounting and Installers Choice       Hunter s patented 3 position mounting system provides you maximum  installa
15. ll switch  Wait 30 seconds   then resume power to the fan     If you need parts or service assistance  please call  888 830 1326  In Canada  call 866 268 1936  or  visit us at our Web site at  http   www hunterfan com     Hunter Fan Company  7130 Goodlett Farms Parkway  400  Memphis  Tennessee 38016       16  42654 01   03 08 10    Hunter Fan Company             
16. ons to airflow  such as walls or  posts  within 30 inches of the fan blade tips     e The fan is directly below a joist or support brace that will hold the  outlet box and the full weight of the fan     Checklist for Existing Fan Site    30    From  Wall or  Nearest    Obstruction 7    Minimum  Blades to  Floor    8    Minimum       If you want to use an existing fan site  complete the following checklist to Fan Support    determine if the site is acceptable and safe for your new Hunter fan  If you  cannot check off every item  prepare a new fan site as described on this    page   Fan Support System   e Fan attaches directly to building structure    e Fan support system will hold full weight of the fan and light kit    Ceiling Hole      The outlet box clearance hole is directly below the joist or support brace   Outlet Box    e The outlet box is an UL approved octagonal 4    x 1 1 2    outlet box  or as  specified by the support brace manufacturer      e The outlet box is secured to the joist or support brace by wood screws  and washers through the inner holes of outlet box        The outer holes of the outlet box are aligned with joist or support brace    e The bottom of the outlet box is recessed a minimum of 1 16    into  ceiling    Wiring   e The electrical cable is secured to outlet box by an approved connector    e Six inches of lead wires extend from outlet box           Fan Support  System    Outlet Box          If your existing fan site is suitable  skip ahead to Sec
17. tion 2    Installing the  Ceiling Plate     3    42654 01   03 08 10    Hunter Fan Company                Ceiling  Height          Preparing the Fan Site  continued        Step 2   Cut the Ceiling Hole   2 1  Locate the site for the ceiling hole directly below the joist or support brace that  will hold the outlet box and fan    2 2  Cut a 4    diameter hole through the drywall or plaster of the ceiling  You will use  the hole to install the support brace and outlet box     Step 3   Install a Support Brace  If Necessary    Determine if there is a ceiling joist directly above the ceiling hole  If the joist is there    determine if it is positioned to allow you to recess the outlet box a minimum of   1 16    into the ceiling  If NOT  install a support brace as follows    3 1  Attach a 2    x 4    support brace between two joists  Position it to allow you to  recess the bottom of the outlet box a minimum of 1 16    into the ceiling    3 2  Check the support brace to ensure it will support the full weight of the fan and  light kit     Step 4   Install the Outlet Box    4 1  Obtain a UL approved octagonal 4    x 1 1 2    outlet box  plus two  8 x 1 1 2     wood screws and washers  available from any hardware store or electrical supply  house     4 2  Orient the outlet box so that both the inner and outer holes in the box align  with the joist or support brace    4 3  Drill pilot holes no larger than the minor diameter of the wood screws  5 64      through the inner holes of the out
18. tion flexibility and ease  You can install your Hunter fan in one  of three ways  depending on ceiling height and your preference  Low  Profile  Standard  or Angled mounting  The steps in this manual include    Support Brace             Ceili f   j      Standard m Box   instructions for all three Installer   s Choice mounting methods   Mounting  gt   Style Considering Optional Accessories          Consider using Hunter s optional accessories  including a wall mounted  or remote speed control  To install and use the accessories  follow   the instructions included with each product  For quiet and optimum  Standard Mounting hangs from the performance of your Hunter fan  use only Hunter speed controls                 ceiling by a downrod  included         For ceilings higher than 8 feet  you can purchase  Hunter extension downrods  All Hunter fans use    sturdy 3 4    diameter pipe to assure stability and  wobble free performance              Support Brace         A CAUTION  To  reduce the risk of  personal injury  attach  the fan directly to the  support structure of  the building according  to these instructions   and use only the  hardware supplied           Low Profile ad    Mounting  Style       Outlet Box                               Angled Mounting recommended for a Low Profile Mounting fits close to the  vaulted or angled ceiling ceiling  recommended for ceilings less  than 8 feet high    5    42654 01   03 08 10    Hunter Fan Company                   l   Getting Ready 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Instruções de operação  Genie 2060 Garage Door Opener User Manual  Function of Gmate  SMART 3.0.00D.indd  AA ARC administrators guide.book    Copyright © All rights reserved. 
   Failed to retrieve file