Home

Hunter Fan 42177 Thermostat User Manual

image

Contents

1. P IS Owner s Guide and Installation Manual For reference also attach your receipt or a copy of your receipt to the manual Warrenty Assistonre Type 2 Mode SINCE 1886 Form 42693 01 20091111 2009 Hunter Fan Co Welcome Your new Hunter ceiling fan is an addition to your home or office that will provide comfort and performance for many years This installation and operation manual gives you complete instructions for installing and operating your fan We are proud of our work We appreciate the opportunity to supply you with the best ceiling fan available anywhere in the world Before installing your fan for your records and warranty assistance record information from the carton and Hunter nameplate label located on the top of the fan motor housing Table Of Contents Cautions and Warnings e READ THIS ENTIRE MANUAL CAREFULLY BEFORE BEGINNING INSTALLATION SAVE THESE INSTRUCTIONS e Use only Hunter replacement parts 2 Installing the Ceiling Plate e To reduce the risk of personal injury attach the fan directly to the 3 e Assembling and Hanging the Fan 8 support structure of the building according to these instructions and use only the hardware supplied To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off posit
2. 4 1 Make sure the power is still off 4 2 To connect the wires hold the bare metal leads together and place a wire connector over them then twist clockwise until tight For all these connections use the wire connectors provided A CAUTION Be sure no bare wire or wire strands are visible after making connections downrod or low profile washer 4 4 Using the large wire connector connect the white wires and the black wires from the ceiling as follows e The white Common power wire from the ceiling to the white wire from the receiver marked on red tag NEUTRAL IN e The black power wire from the ceiling to the black wire from the receiver marked on white tag LIVE IN 4 5 Using the small wire connector connect the wires from the fan as follows The black wire from the fan to the red wire from the receiver marked on red tag FAN OUT e The white wire from the fan to the white wire from the receiver marked on white tag COMMON OUT e The black white wire from the fan to the black white wire from the receiver marked on white tag LIGHT OUT 4 6 Check each connection to make sure no bare wire or wire strands are visible Push all wires and wire connectors back through the ceiling plate hole into the outlet box 4 7 Run the white antenna wire from the receiver around the inside of the canopy for clear reception 9 e 11 11 09 Hunter Fan Company Connect the groun
3. Assembly Upper Screw Switch screws are firmly situated in the narrow end of the keyhole slots Install the remaining screw into the housing Tighten all three screws firmly Housing A CAUTION Make sure the upper switch housing is securely attached to the switch housing mounting plate Failure to properly attach and tighten all three assembly screws could result in the switch housing and light fixture falling 8 5 If you want to install the light fixture proceed with step 8 6 now If you do not want to install the light fixture you need to uninstall it now See Uninstalling the Light Fixture on step 8 14 Once you have uninstalled the light fixture continue with step 8 6 13 42693 01 11 11 09 Hunter Fan Company 8 8 6 To attach the lower switch housing connect the upper plug 8 7 e Completing Your Installation With or Without a Bowl Light Fixture Continued connector from the motor to the lower plug connector in the lower switch housing assembly Note Both plug connectors are polarized and will only fit together one way Make sure the connectors are properly aligned before connecting them Incorrect connection could cause improper operation and damage to the product lt Plug Connector Place the lower switch housing assembly over the upper switch housing Align the side screw holes in the upper and lower switch housings Attach the lower switch housing
4. sets as they were shipped 42693 01 11 11 09 Hunter Fan Company 2 Installing the Ceiling Plate A CAUTION To avoid possible electrical shock before installing your fan disconnect the power by turning off the circuit breakers to the outlet box and associated wall switch location If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 2 1 2 2 2 3 2 4 Drill two pilot holes into the wood support structure through the outermost holes in the outlet box The pilot holes should be 9 64 in diameter For Angled Ceilings Be sure to orient the ceiling plate so that the two tabs are pointing toward the ceiling peak Your fan comes with four preinstalled noise isolators Check to make sure all four isolators are in place and were not removed during shipment Place a flat washer on each of the two 3 wood screws Thread the supply wires from the outlet box in the ceiling through the hole in the center of the ceiling plate Align the slotted holes in the ceiling plate with the pilot holes you drilled in the wood support structure For proper alignment use slotted holes directly across from each other Note The isolators should be flush against the ceiling Pass the screws through the slotted holes in the ceiling plate into the pilot holes you drilled Tighten the screws into the 9 64 pilot hole
5. ameter of the wood screws 5 64 through the inner holes of the outlet box 4 4 Attach the outlet box directly to the support brace or joist with two 8 x 1 1 2 wood screws and washers Th e bottom of the outlet box must be recessed a minimum of 1 16 into the ceiling Step 5 Prepare the Wiring 5 1 Make sure the circuit breakers to the fan supply line leads and associated wall switch location are turned off If you cannot lock the circuit breakers in the off position securely fasten a prominent warning device such as a tag to the service panel 5 2 Thread the fan supply line through the outlet box so that the fan supply line extends at least 6 beyond the box 5 3 Attach the fan supply line to the outlet box with an approved connector available at any hardware store or electrical supply house 5 4 Make certain the wiring meets all national and local standards and ANSI NFPA 70 You have now successfully prepared your ceiling fan site For instructions to install your ceiling fan go to your fan manual and continue with Section 2 Installing the Ceiling Plate 4 42693 01 11 11 09 Hunter Fan Company A CAUTION All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician Installer s Choice and Optional Accessories Support Brace Ceiling Standard Outle
6. d wire from the ceiling to the green ground wire from the ceiling plate and the green ground wire from the You must now set the jumpers in the remote 5 Setting the Remote Transmitter and Receiver Example DIP Switch Settings transmitter and DIP switches in the receiver so that they match Setting DIP switches and Jumpers When two or more fans are located near each other you may desire to have the receiver transmitter for each fan set to a different code so that the operation of one fan does not affect the operation of the other fans The DIP switches for the receiver are located on the flat surface of the receiver The Jumpers for the transmitter are in the the battery compartment 5 1 IMPORTANT Before you change the Jumper settings make sure the battery is not connected to the transmitter Change the position of the jumpers in the transmitter and the DIP switches in the receiver Be sure the position of the jumper in the transmitter matches the position of the DIP switches in the receiver If they don t match the controller will not function For instructions on how to set the jumpers read the box below 5 2 Install the included 12 volt battery into the transmitter A CAUTION The remote control device complies with part 15 of the FCC rules Changes or modifications not expressly approved by Hunter Fan Company could void your authority to operate this equipment Operation is subject to the following two condition
7. ed If so replace all the blades Problem Excessive wobbling 1 If your fan wobbles when operating use the enclosed balancing kit and instructions to balance the fan 2 Tighten all blade iron screws 3 Turn power off support fan very carefully and check that the hanger ball is properly seated In compliance with U S Federal regulations this ceiling fan contains a wattage saver that limits the light output to 190 Watts The following issues may arise if total wattage exceeds 190 Watts Issue Lights dim when turned on 1 It is normal for the lights to dim a couple of seconds after they are turned on To prevent the lights from dimming make sure the wattage of light bulbs installed match the specifications on the light sockets Issue Light shuts off suddenly 8 y If you need parts or service assistance please call 1 Turn the power to the fan off at the wall switch Wait 888 830 1326 In Canada call 1 866 268 1936 or 30 seconds then resume power to the fan visit us at our Web site at 2 If lights shut off suddenly again check to make sure http www hunterfan com total wattage of bulbs does not exceed 190 Watts Hunter Fan Company 7130 Goodlett Farms Pkwy 400 Memphis Tennessee 38016 19 42693 01 11 11 09 Hunter Fan Company
8. eet high The fan blades have no obstructions to airflow such as walls or posts within 30 inches of the fan blade tips e The fan is directly below a joist or support brace that will hold the outlet box and the full weight of the fan 30 From Wall or Nearest Obstruction 7 Minimum Blades to Floor 8 Minimum Checklist for Existing Fan Site If you want to use an existing fan site complete the following checklist to Fan Support determine if the site is acceptable and safe for your new Hunter fan If you cannot check off every item prepare a new fan site as described on this page Fan Support System e Fan attaches directly to building structure e Fan support system will hold full weight of the fan and light kit Ceiling Hole The outlet box clearance hole is directly below the joist or support brace Outlet Box e The outlet box is an UL approved octagonal 4 x 1 1 2 outlet box or as specified by the support brace manufacturer The outlet box is secured to the joist or support brace by wood screws and washers through the inner holes of outlet box The outer holes of the outlet box are aligned with joist or support brace e The bottom of the outlet box is recessed a minimum of 1 16 into ceiling Wiring e The electrical cable is secured to outlet box by an approved connector e Six inches of lead wires extend from outlet box Suitable Existing Fan Site Fan Support Ou
9. h the mounting holes on the ceiling plate A WARNING The slots in the canopy must remain engaged while swinging the canopy for alignment 6 3 Holding the canopy up with the screw holes aligned partially install two canopy screws into the holes opposite the ceiling plate tabs 6 4 Partially install a canopy screw into the hole between the two ceiling plate tabs When all the holes are properly aligned securely tighten all three canopy screws 6 5 Verify that the tabs in the canopy are still in the grooves of the hanger ball 6 6 Align the tabs on the trim ring opposite the grooves in the hanger ball Using both hands push the canopy trim ring up to the top of the canopy The canopy trim ring will snap and lock into place Note Should you need to remove the trim ring press firmly on opposite sides of the trim ring directly above the groove in the hanger ball The tabs will flex out releasing the canopy trim ring Step 6 1 Step 6 2 Step 6 3 Canopy gt Canopy Trim Canopy Screw lI 42693 01 11 11 09 Hunter Fan Company 7 Assembling the Blades Hunter fans use several styles of fan blade irons brackets that hold the blade to the fan 7 1 Your fan may include blade grommets If your fan has grommets Step 7 1 Detail insert them by hand into the holes on the blades 7 2 Attach each blade to a blade iron using three blade assembly screws If y
10. ion securely fasten a prominent warning device such as a tag to the service panel All wiring must be in accordance with national and local electrical Preparing the Fan Site 1 e Getting Ready 4 Wiring the Fan 5 e Setting the Remote Transmitter and Receiver 6 Installing the Canopy and Canopy Trim Ring 7 Assembling the Blades 8 e Completing Your Installation With or codes and ANSI NFPA 70 If you are unfamiliar with wiring use a Without a Bowl Light Fixture qualified electrician 9 Operating and Cleaning Your e To reduce the risk of personal injury do not bend the blade Ceiling Fan attachment system when installing balancing or cleaning the fan Never insert foreign objects between rotating fan blades To reduce the risk of fire electrical shock or motor damage do not use a solid state speed control with this fan Use only Hunter speed controls 10 Operating the Remote Control 18 11 Troubleshooting 2009 Hunter Fan Company 2 42693 01 11 11 09 Hunter Fan Company Preparing the Fan Site Step 1 Choose the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings Choose a fan site where e No object can come in contact with the rotating fan blades during normal operation e The fan blades are at least 7 feet above the floor and the ceiling is at least 8 f
11. n the In cold weather use upward same manner as the fan finish air flow pattern To Change Airflow Direction y LN Y AKE y Turn the fan off and let it come to a complete stop Slide the reversing switch on the fan to the A opposite position Restart fan Va N Y Reversing Switch TT n AN Mia Y 17 42693 01 11 11 09 Hunter Fan Company 10 2 10 3 10 4 10 Operating the Remote Control The remote transmitter has individual buttons for turning the fan and the light off and on Use the Light buttons to turn the Light On and Off Use the Fan buttons to turn the Fan On and Off l Light Off When necessary replace the battery with a 12 volt type 23A MN 21 battery or equivalent Fan Off Steps 10 2 10 3 Light On Fan On Step 10 4 18 42693 01 11 11 09 Hunter Fan Company 11 Troubleshooting Problem Nothing happens fan does not move 1 Turn power on replace fuse or reset breaker 2 Loosen canopy check all connections according to the wiring the fan section 3 Check the plug connection in the switch housing 4 Push motor reversing switch firmly left or right to ensure that the switch is engaged 5 Pull the pull chain to ensure it is on 6 Remove the shipping bumpers Problem Noisy operation 1 Tighten the blade assembly screws and blade iron armature screws until snug 2 Check to see if the blade is crack
12. ng and Cleaning Your Ceiling Fan 9 1 Turn on electrical power to the fan 9 2 The fan pull chain controls power to the fan The pull chain has four settings in sequence High Medium Low and Off e Pull the chain slowly to change settings e Release slowly to prevent the chain from recoiling into the blades e The chain uses a breakaway connector that separates if the chain is jerked If this happens simply reinsert the chain into the connector 9 3 The light pull chain controls the power to the light fixture The In warm weather use chain has two settings ON and OFF downward air flow pattern 9 4 Ceiling fans work best by blowing air downward counterclockwise blade rotation in warm weather to cool the room with a direct breeze In winter having the fan draw air upward clockwise blade rotation will distribute the warmer air trapped at the ceiling around the room without causing a draft 9 5 For cleaning finishes use a soft brush or lint free cloth to prevent scratching A vacuum cleaner brush nozzle can remove heavier dust Remove surface smudges or accumulated dirt and dust using a mild detergent and a slightly dampened cloth You may use an artistic agent but never abrasive cleaning agents as they will damage the finish 9 6 Clean wood finish blades with a furniture polishing cloth Occasionally apply a light coat of furniture polish for added protection and beauty Clean painted and high gloss blades i
13. ou used grommets the blades may appear slightly loose after screws are tightened This is normal 7 3 Remove the blade mounting screws and rubber shipping bumpers from the motor Note Some blade mounting screws are installed in the motor to secure shipping blocks 7 4 For each blade insert one blade mounting screw through the blade iron and attach lightly to the fan Insert the second blade mounting screw then securely tighten both mounting screws Blade Assembly Use with grommet ews Use without grommet Blade Mounting Screw 12 42693 01 11 11 09 Hunter Fan Company Steps 7 1 7 2 8 Completing Your Installation With or Without a Bowl Light Fixture Your Hunter fan comes with an integrated light fixture assembly and an optional switch housing cap and plug button This feature gives you the option of installing the fan with OR without the included light fixture The steps below direct you whether or not you are installing a light fixture A WARNING Use only the light fixture supplied with this fan model 8 1 To attach the upper switch housing partially install two housing assembly screws into the switch housing mounting plate 8 2 Feed the upper plug connector through the center opening of the housing 8 3 Align the keyhole slots in the housing with the housing assembly screws Steps 8 1 8 3 Housing 8 4 Turn the housing counterclockwise until the housing assembly
14. s 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Note Use with a fan that incorporates an air gap switch normal on off wall switch A WARNING Maximum fan load is 1 Amp maximum lamp is 100 Watts Do not use any speed control with this product 10 Receiver 2 DIP Switches Set to 0111 Transmitter 1 OO DIP Switches Set to 0111 Receiver 2 DIP Switches Set to 0100 Transmitter 2 O O U Q DIP Switches Set to 0100 Example Jumpers Settings Receiver 1 4321 Transmitter 1 4321 EEEE IUIL 4 off apagado 3 on encendido 2 on encendido 1 on encendido Receiver 2 Transmitter 2 3 2 E B 4321 HOE T 4 off apagado 3 on encendido 2 off apagado 1 on encendido 42693 01 11 11 09 Hunter Fan Company Receiver DIP switches Remote Transmitter Jumper Switches 6 Installing the Canopy and Canopy Trim Ring A WARNING Failure to complete the following steps could cause the fan to fall Note It is recommended you use a magnetic tip screwdriver for the following steps 6 1 Rotate the hanger ball so the tab in the canopy is secure in the hanger ball groove Note Your fan may have multiple tabs and grooves that must be aligned 6 2 Swing the fan up to align the canopy screw holes wit
15. s do not use lubricants on the screws Do not over tighten Flat Washer 3 Wood Screw a 7 42693 01 11 11 09 Hunter Fan Company Toward Ceiling Peak For Angled Ceilings Be sure to orient the ceiling plate so that the two tabs are pointing toward the ceiling peak Steps 2 3 2 6 3 Assembling and Hanging the Fan A WARNING Fan may fall if not assembled as directed in these installation instructions 3 1 Unbundle the wires from the fan For Standard or Angled mounting 3 2 Insert the downrod through the canopy and canopy trim ring Feed the wires from the fan through the downrod on one side of the pin in the ball 3 3 Loosen the square head setscrew on the adapter to install the pipe and ball assembly Note When the pipe and ball assembly is fully installed 2 3 threads on the pipe will still be visible this is normal Securely retighten the setscrew with a wrench or pliers Skip to step 3 7 A CAUTION The adapter has a special coating on the threads Do not remove this coating the coating prevents the downrod from unscrewing Once assembled do not remove the downrod For Low Profile mounting Note For low profile mounting the downrod is replaced with the low profile washer 3 4 Remove the setscrew from the adapter 3 5 Place the low profile washer into the canopy with the lip down 3 6 Align the holes in the washer with the holes in the adapter As
16. semble securely with three low profile screws Hanging the Fan Note To hang the fan you must tilt the canopy to an almost vertical position so that the canopy slots sit on the ceiling plate hooks 3 7 Raise the fan and align the slots in the canopy with the hooks on the ceiling plate 3 8 Place the slots over the hooks to hang the fan 8 Standard or Angled Mounting Steps 3 2 3 3 3 m Downrod lt Canopy lt Canopy Setscrew Trim Ring Low Profile Mounting Steps 3 5 3 6 Low Profile Screws E Fa a Ground Asier Wire Canopy Trim Ring a N Low Profile Screw Step 3 6 Detail Adapter Low Profile Screw Low Profile Washer 42693 01 11 11 09 Hunter Fan Company Receiver Step 4 3 A Ground Green Step 4 4 B Ceiling Black e Receiver Black LIVE IN C Ceiling White e Receiver White NEUTRAL IN Step 4 5 D e Fan Black White e Receiver Black White LIGHT OUT E Fan Black e Receiver Red FAN OUT F Receiver White COMMON OUT e Fan White Steps 4 3 4 7 Large Wire Small Wire Connector Connector 42693 01 P j if 4 s S B 4 Wiring the Fan All wiring must be in accordance with national and local electrical codes and ANSI NFPA 70 If you are unfamiliar with wiring use a qualified electrician
17. t Box Mounting gt Style Standard Mounting hangs from the ceiling by a downrod included Angled Mounting recommended for a vaulted or angled ceiling Understanding Mounting and Installers Choice Hunter s patented 3 position mounting system provides you maximum installation flexibility and ease You can install your Hunter fan in one of three ways depending on ceiling height and your preference Low Profile Standard or Angled mounting The steps in this manual include instructions for all three Installer s Choice mounting methods Considering Optional Accessories Consider using Hunter s optional accessories including a wall mounted or remote speed control To install and use the accessories follow the instructions included with each product For quiet and optimum performance of your Hunter fan use only Hunter speed controls For ceilings higher than 8 feet you can purchase Hunter extension downrods All Hunter fans use sturdy 3 4 diameter pipe to assure stability and wobble free performance Support Brace Low Profile ad Mounting Style Outlet Box Low Profile Mounting fits close to the ceiling recommended for ceilings less than 8 feet high 5 42693 01 11 11 09 Hunter Fan Company A CAUTION To reduce the risk of personal injury attach the fan directly to the support structure of the building according to
18. the B10 Candelabra Base 60 Watt Maximum end of the extra chain Metal Rod Glass Bowl Cover Plate Breakaway Finial Connector a 42693 01 11 11 09 Hunter Fan Company 8 e Completing Your Installation With or Without a Bowl Light Fixture Continued Uninstalling the Light Fixture 8 14 To uninstall the light fixture first disconnect the plug connectors 8 15 8 16 8 17 between the black wire and the red wire Disconnect the plug connectors between the two white wires Remove the two screws attaching the light kit to the lower switch housing Remove the light fixture from the lower switch housing pulling disconnected wires through the hole in the center of the lower switch housing Lie ie ie if i fe Ee i 2 E me Note When removing the wires pull the thin plug connector male through first and then pull the other plug connector Lower Switch female through the hole POUSINE Install the dummy terminals included in the sack parts on the two disconnected wires in the lower switch housing Install the switch housing cap and plug button to the lower switch housing Once you have uninstalled the light fixture continue with step 8 6 Step 8 16 Male Dummy Terminal Female Dummy Terminal Plug Button _ gt Step 8 19 16 42693 01 11 11 09 Hunter Fan Company 9 Operati
19. these instructions and use only the hardware supplied l Getting Ready To install a ceiling fan be sure you can do the following e Locate the ceiling joist or other suitable support in ceiling e Drill holes for and install wood screws e Identify and connect electrical wires e Lift 40 pounds If you need help installing the fan your Hunter fan dealer can direct you to a licensed installer or electrician Gathering the Tools You will need the following tools for installing the fan e Electric drill with 9 64 bit e Standard screwdriver magnetic tip recommended e Phillips head screwdriver magnetic tip recommended e Wrench or pliers e Ladder height dependent upon installation site Checking Your Fan Parts Carefully unpack your fan to avoid damage to the fan parts Refer to the included Parts Guide Check for any shipping damage to the motor or fan blades If any parts are missing or damaged contact your Hunter dealer or call Hunter Technical Support Department at 888 830 1326 In Canada call 1 866 268 1936 Preparing the Fan Site Before you begin installing the fan follow all the instructions in Preparing the Fan Site Proper ceiling fan location and attachment to the building structure are essential for safety reliable operation maximum efficiency and energy savings 6 Installing Multiple Fans If you are installing more than one fan keep the fan blades and blade irons if applicable in
20. tlet Box If your existing fan site is suitable skip ahead to Section 2 Installing the Ceiling Plate 3 42693 01 11 11 09 Hunter Fan Company Ceiling Height Preparing the Fan Site continued Step 2 Cut the Ceiling Hole 2 1 Locate the site for the ceiling hole directly below the joist or support brace that will hold the outlet box and fan 2 2 Cut a 4 diameter hole through the drywall or plaster of the ceiling You will use the hole to install the support brace and outlet box Step 3 Install a Support Brace If Necessary Determine if there is a ceiling joist directly above the ceiling hole If the joist is there determine if it is positioned to allow you to recess the outlet box a minimum of 1 16 into the ceiling If NOT install a support brace as follows 3 1 Attach a 2 x 4 support brace between two joists Position it to allow you to recess the bottom of the outlet box a minimum of 1 16 into the ceiling 3 2 Check the support brace to ensure it will support the full weight of the fan and light kit Step 4 Install the Outlet Box 4 1 Obtain a UL approved octagonal 4 x 1 1 2 outlet box plus two 8 x 1 1 2 wood screws and washers available from any hardware store or electrical supply house 4 2 Orient the outlet box so that both the inner and outer holes in the box align with the joist or support brace 4 3 Drill pilot holes no larger than the minor di
21. to the upper switch housing with three housing assembly screws Steps 8 6 8 7 Lower Switch Housing Note In compliance with U S Federal energy regulations this Plug T ceiling fan contains a wattage saver that restricts the light a kit to a maximum of 190 Watts Exceeding that limit or the specifications on the light sockets may result in fire hazard or improper operation If lights do not appear to be operating properly see the troubleshooting section Housing Assembly Screw 14 42693 01 11 11 09 Hunter Fan Company 8 e Completing Your Installation With or Without a Bowl Light Fixture Continued Installing the Glass Bowl 8 8 First install B10 candelabra bulbs 60 Watt Maximum into the sockets Thread the light and fan pull chains through the hole in the center of the glass bowl Then thread the light pull chain through the hole in the center of the cover plate Thread the fan pull chain through the grommet hole in the side of the cover plate Place the cover plate up against the glass bowl Align the holes in the cover plate and glass bowl Thread the light pull chain through the finial and screw the finial onto the threaded rod end until tight 8 13 Attach the extra pull chains included to the light and fan pull hains using the plastic break tor Y find th chains using e plastic DreakKaway connec or ou May Tin e Light Bulbs plastic breakaway connector on

Download Pdf Manuals

image

Related Search

Related Contents

Commune de Woluwe-Saint-Pierre  Manual de Instrucciones  Sony VAIO VGNAR User's Manual  918 Spyder  Uso de la computadora VAIO  HANDY-FUEL  IBM PC Server Hardware Maintenance Manual  - All IT eBooks  ca. 5 Mb - NVG Normteilvertriebsgesellschaft mbH  LOEWE Individual 40" 40" Full HD 3D compatibility Black  