Home
Honeywell HR200 Ventilation Hood User Manual
Contents
1. WORK IN A MORE Honeywell F35 media air COMFORTABLE ENVIRONMENT cleaner or F50 electronic air son CHRONOTHEAME 1v t HONEYWELL ELECTRONC PROGRAMMABLE cleaner o iamen er ME Honeywell humidistat and Id humidifier e Honeywell digital electronic UNAR i t CONDITIONED CONDITIONED REGISTER REGISTER timer ome moneo REGI i STALEAR EXHAUST OPTIMAL EFFICIENCY AR CONDITIONER e 1 Cc JU RETAMA HUMIDIFIER COLD AIR F a RETURN y STALE FRESHAIR AKE OPTIMAL AIRFROM INT EFFICIENCY i FORCED AIR Da FURNACE PERFICT Q FRESH WINDOW NOME FRESH AIR j VENTILANI ON HONEYWELL ELECTRONIC AIR CLEANER idiin M11703 AR AAA 69 0994 4 10 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Troubleshooting Lack of power to the ventilator e power failure of electrical box loose or unplugged power cord e faulty breaker or fuse in home s electrical panel call your installation contractor Power to the ventilator but no fan operation e ventilator is in standby mode and optional remote dehumidistat is set to OFF or the humidity setting is higher than room humidity door Is not closed properly the safety interlock switch will keep the ventilator off Check that the access door is firmly closed and latched e refer to operating instructions call your installation con
2. H channel Mount either side core guide followed by the other side Mount the top core guide into the top H channel With all four comers in place and the core straight and even push on the core center until the core slides to the back of the cabinet PONS NOTE The core will appear to stick out from the cabinet approximately 1 8 in 3mm It is designed this way so that the access door will fit tightly against the core 69 0994 4 8 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS DRAIN LINE Clean the drain line once a year 1 Inspect the drain line drain spout and P trap for blockage mold or kinks 2 Flush with warm soapy water and replace if worn or bent or if it can not be cleaned GENERAL MAINTENANCE Twice a year wipe down the inside of the cabinet with a damp cloth to remove dirt bugs and debris that can be present FANS If the fans accumulate dirt it could cause an imbalance and excessive vibration of the ventilator A reduction in air flow can also occur In a newly constructed house this often happens within the first year due to heavy dust residue in the entire system It can also occur periodically depending on the outdoor conditions If you suspect that service is required please contact the ventilator installer or your local HVAC contractor 9 69 0994 4 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Perfect Climate Control Describing Perfection The m
3. Honeywell HR150 and HR200 Perfect Window Fresh Air Ventilation Systems OWNER S MANUAL M11706 U S Registered Trademark Copyright O 2002 Honeywell All Rights Reserved 69 0994 4 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS TABLE OF CONTENTS IMTFOGUCTION 2s A ek ease ha pal hye ee ate eee ee sd ee eles 4 Feeling right athome 000 eee 4 What your Perfect Window Fresh Air Ventilation System consists of 4 Operating your Fresh Air Ventilation System 002000 0c eee ee 6 Getting the most from your Fresh Air Ventilation SysteM 7 Maintenance of your Fresh Air Ventilation SysteM 0oo ooo ooooo oo 8 Perfect Climate Control os scsi taere tte 12 Troubleshooting mes iake k ae ole Dede hate a eins lal tS 13 Warranty ss Eosen e eas eee ag ee ye hh de 14 69 0994 4 2 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Introduction We take it for granted that our homes will protect us from the elements but because of tighter better quality home construction our indoor environment may be exposing us to unacceptable levels of the very things we are trying to escape Excessive heat dryness humidity toxic gases and dust contaminants can be sealed in securely by weatherproofing So what s the forecast for indoors Today s indoor forecast is stormy weather for many homeowners But rapid clearing and fresh br
4. d above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY EXPRESS OR IMPLIED OR ANY OTHER FAILURE OF THIS PRODUCT Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation may not apply to you THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you This warranty gives you specific legal rights and you may have other rights which vary from state to state If you have any questions concerning this warranty please write Honeywell Customer Relations 1985 Douglas Dr N MN10 1461 Golden Valley MN 55422 In Canada write Honeywell Limited Honeywell Limit e 35 Dynamic Dr ON15 Scarborough Ontario M1V 429 Honeywell Automation and Control Solutions Honeywell Honeywell Limited Honeywell Limit e 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Southborough Ontario MIV 4Z9 69 0994 4 G H Rev 01 02 Printed in Canada www honeywell com yourhome
5. eezes are just around the corner Feeling right at home Unlike what the outdoors brings us you can have control of indoor conditions Temperature humidity levels and air quality can all affect physical health mental attitude general comfort and energy savings With today s technological advances you can achieve a Perfect Climate indoors After all people look to their homes as a place to escape the stress of work a busy lifestyle and an increasingly polluted outdoor environment Creating a perfect indoor climate is becoming critical to feeling right at home The Honeywell Perfect Window Fresh Air Ventilation System removes stale unhealthy air and replaces it with a stream of fresh air Its powerful centrifugal blowers bring fresh air into your home and at the same time exhaust stale humid air in an equal amount Both incoming and outgoing airstreams pass through a heat exchange core where the energy from the exhaust air is efficiently transferred to the incoming fresh air An air duct system supplies the fresh air brought in by the Perfect Window ventilator and distributes it throughout your home Another duct draws the existing stale humid air back to the Perfect Window ventilator and then exhausts it outdoors It s really very simple and remarkably effective What your Perfect Window Fresh Air Ventilation System consists of 1 Air Circulation Pan and Motor Inside the casing are two fans one for exhaus
6. for the ventilator should be set at least 10 higher in this case 40 With the ventilator operating on low speed and no one is home to produce humidity the humidifier will keep the humidity level to its setpoint If the humidity levels rise due to occupant activity above the 40 level then the dehumidistat will automatically increase the speed of the ventilator fan to high until the humidity level falls below 40 TIMER For your convenience Honeywell provides a timer control that can fit a wide variety of needs for example exhaust humid air from the bathroom or kitchen see the installation guide for selection and part numbers WALL SWITCH A wall switch can also be used to switch your ventilator fan speed to high The fan will run at high speed until the wall switch is turned off When any remote device is activated the ventilator will run at high speed All remote devices must be in the off position to return the fan to the speed manually selected on the rotary fan speed control knob Getting the most from your Fresh Air Ventilation System HOW MUCH VENTILATION DO NEED During the seasons that your windows and doors are closed winter and summer if you have air conditioning the ventilator should operate continuously when the home is occupied and either continuously or intermittently when not occupied For most installations the ventilator will normally be set to operate continuously on low speed with the option of going to
7. ge Hood blockage can cause a change of pressure in building which can lead to possible spillage from combustible appliances AIR FILTERS Air filters should be cleaned twice a year The standard filters supplied with your ventilator are removable and washable 1 Open access door and slide out core Refer to Core Maintenance section for cleaning instructions 2 Remove filter clip 3 Remove filters from the core and rinse with water or a combination of soap and water Do not clean in a dishwasher 4 After cleaning place filters wet or dry back in their position and reattach the retaining clip 7 69 0994 4 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS CORE Clean the core twice each year FILTER CLIP Y 4 1 AAN SN te z El A FILTER 7 CORE GUIDE MANUAL CONTROL MODEL M170A 1 Open the access door and carefully grip the ends of the core and pull evenly out ward The core can be snug but it will slide out of the cabinet NOTE Do not handle the fins because damage can occur 2 Once out of the cabinet remove the filters refer to Air Filter Maintenance sec tion 3 Wash the core in warm soapy water do not use a dishwasher 4 Reinstall the clean filters 5 Reinstall the clean core NOTE Do not detach the foam on the ends of the core or the core label water does not damage them To install the clean core First mount the bottom core guide into the bottom
8. high speed as the need arises For example if you are entertaining and there is a large number of people present some may be smoking the ventilator should be switched to high speed YOUR VENTILATOR MAY BE SET TO HIGH SPEED BY 1 selecting the highest speed on the ventilator or 2 if the system includes an optional remote control switch it to the ON position NOTE To set the dehumidistat refer to the previous section of this booklet To oper ate other remote devices refer to the device owner s manual 69 0994 4 6 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Maintenance Instructions for your Fresh Air Ventilation System A WARNING Electrical Shock Hazard Can cause personal injury or equipment damage Disconnect power supply before performing maintenance The Perfect Window Fresh Air Ventilation System must be maintained on a regular basis for best efficiency Honeywell recommends that the ventilator be cleaned and checked at least twice a year preferably at the beginning of each heating and cooling season Check and Clean EXTERIOR HOODS Exterior hoods should be inspected at least once a month Be sure exhaust and fresh air supply hoods are not blocked up or restricted by leaves grass or snow In winter it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh bird screen A WARNING Can cause personal injury or equipment dama
9. ition the ventilator will not function until energized by a remote control see information below It is up to the individual homeowner to set their system to a speed which they find comfortable If you feel your house is stuffy or there is an above average occupancy rate you may need to increase your ventilation In most applications a low to medium speed setting is comfortable POWER CORD RECOMMENDED Je MAINTENANCE 4 SPEED CONTROL PO Te l WITH STANDBY POSITION PRODUCT IDENTIFICATION LABEL NOTE THIS INFORMATION IS VERY IMPORTANT WHEN MAKING INQUIRIES ABOUT YOUR ERV M11704A Connecting a Remote Device Your ventilator comes equipped with a low voltage terminal strip for connection to several optional control devices PERFECT CLIMATE COMFORT CENTER CONTROL The Honeywell Perfect Climate Comfort Center unit controls your ventilator automatically by using the programmed times or manually by pressing the Ventilate key See the Perfect Climate Comfort Center users guide form 69 0891 for complete instructions 5 69 0994 4 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS EXTERNAL REMOTE WALL CONTROL DEHUMIDISTAT The dehumidistat connected to your ventilator is designed to control the operation of the ventilator fan to help keep the humidity level in your home comfortable If an independent humidifier is installed and set at 30 a normal indoor winter level then the dehumidistat
10. oor air to enter the core to help the defrost Approximately three minutes after the defrost cycle is acti vated the timer will signal the damper to return to its original position for a 2 7 minute period The defrost cycle will repeat until the outside temperature rises above 27 F 3 C Thermally Conductive Core The cross flow heat recovery core transfers heat between the two airstreams The core removes easily for cleaning or service Controls Speed Control Easy operation simply rotate the Perfect Window ventilator fan speed control to your desired setting DEFROST PORT NON DUCTED DAMPER DEFROST MOTOR AND DOOR f FILTERS 2 CORE INSTRUCTIONS HEAT EXCHANGE CORE CABINET A DUCTING 4 PORTS MAIN MOTOR oo SQUIRREL CAGE FAN H CHANNEL CORE GUIDE 4 DRAIN PANS DRAIN P TRAP INSULATED ACCESS DOOR XL DOOR KEEPER PLATE 2 XL DRAIN LINE M11705A FILTER CLIPS 2 69 0994 4 4 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS Operating your Fresh Air Ventilation System Changing Fan Speed The control fan speed is conveniently located on the ventilator The rotary fan speed control knob can be manually set from the off standby position through speeds 1 to 4 Note the fifth speed high is accessible only by a remote control Off standby mode may be used if intermittent ventilation is desired In the off standby pos
11. ost convenient most energy efficient cleanest healthiest and most comfortable indoor environment possible today Perfect climate is achieved when the six core components of your homes climate system work together optimal efficiency of heating and cooling equipment precise programmable temperature control effective indoor air quality control controlled humidity proper ventilation and air distribution zone control for personalized room to room temperature control Products for a Perfect Climate Home HEATING AND COOLING SYSTEM This is the workhorse of your indoor climate system Have your local heating cooling contractor tune up your system annually for comfort safety and most economical operation If your heating equipment is old think about replacing it with a modern and improved unit Recent advances in product technology have substantially increased efficiency of equipment Improved performance often pays back much of the cost of installation within a few short years Honeywell Perfect Window gt e 10 Fresh Air Ventilation System How it works tf uc eee MS Honeywell Perfect Climate le HONEYWELL CLIMATE Comfort Center control or Facs A VENTILATION SYSTEM Mia ual IS ONE PART OF A PERFECT CLIMATES M Chronotherm IV gt INDOOR ENVIRONMENT THAT PROVIDES TOTAL ON s INDOOR COMFORT IT MAKES YOU FEEL BETTER AND 5 programmable thermostat fl ALLOWS YOU TO LIVE AND
12. t and one for fresh air supply The electric motor that operates the fan is 1 15 hp to 1 20 hp depending on the ven tilator model and uses the same amount of power as a 100 watt lightbulb 2 Air Filters There are two permanent washable air filters in your ventilator The filters lower the amount of dust and outside particulates entering the ventilator core and your fresh air supply 3 69 0994 4 HR150 AND HR200 Perfect Window FRESH AIR VENTILATION SYSTEMS 3 Condensate Tray and Drain Condensation normally forms on the heat exchange core during the cold weather below 29 F or 2 C Moisture can build up when the warm air from your home comes in contact with the cold air from outside The tray collects the moisture and funnels it to the drain The drain pans are made of therrnoformed plastic for easy cleaning Defrost Mechanism The built in defrost mechanism will remove frost which can accumulate in colder weather 21 F 6 C and colder The type of defrost mechanism used is known as damper style This consists of an electronically controlled damper door attached to a small electric motor that moves to block off the outside cold air entering the ventilator If the outside temperature drops below 27 F 3 C the defrost timer is activated The timer activates the motor driven damper door mechanism which temporarily moves to close off the outdoor air supply and opens another port on the ventilator that allows warm ind
13. tractor for service CAK of Speed Control let the remote device continue its time setting or manually adjust it to gain speed control test the speed control on the ventilator by turning the variable speed control knob to its highest setting call your installation contractor for service 11 69 0994 4 Limited Warranty Honeywell warrants this product to be free from defects in the workmanship or materials under normal use and service for a period of one 1 year from the date of purchase by the consumer If at any time during the warranty period the product is defective or malfunctions Honeywell shall repair or replace it at Honeywell s option within a reasonable period of time If the product is defective i return it with a bill of sale or other dated proof of purchase to the retailer from which you purchased it or ii package it carefully along with proof of purchase including date of purchase and a short description of the malfunction and mail it postage prepaid to the following address Honeywell Return Goods Dock 4 MN10 3860 1885 Douglas Dr N Golden Valley MN 55422 This warranty does not cover removal or reinstallation costs This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms state