Home
Honeywell 18155 Air Cleaner User Manual
Contents
1. Honeywell Portable True HEPA Air Purifier READ AND SAVE THESE INSTRUCTIONS Install Pre filter Before Initial Use Owner s Manual For LifeTime HEPA Permanent Filter Model 18155 Air Purifier The Science of Clean Air IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER When using electrical appliances basic precautions should always be followed to reduce the risk of fire electric shock and injury to persons including the following 1 Read all instructions before operating the air purifier 2 Place air purifier where it is not easily knocked over by persons in the household 3 Always turn the air purifier to the OFF position and unplug from the wall outlet when not in use 4 To disconnect the air purifier first turn control to the OFF position grip the plug and pull it from the wall outlet Never pull by the cord 5 Do not use any product with a damaged cord or plug or if product malfunctions is dropped or damaged in any manner Keep the cord away from heated surfaces 6 Do not use air purifier outdoors 7 Never use air purifier unless it is fully assembled 8 Do not run power cord under carpets and do not cover with throw rugs Arrange cord such that it will not be tripped over Do not use air purifier where combustible gases or vapors are present 10 Do not expose the air purifier to rain or use near water in a bathroom la
2. if pre filter needs replacement To vacuum clean the filter hold the filter and run a vacuum cleaner with a nozzle or brush attachment along the filter to pick up the dirt and particles Fig 4 Repeat along the entire surface of the HEPA filter Do not penetrate the HEPA paper pleats with the vacuum attachment since tearing or puncturing can occur Note that the filter may still be discolored even after cleaning it This is acceptable and will not affect performance After vacuuming the filter wrap the pre filter around the HEPA filter and place the whole assembly back into the internal chamber of the air purifier see Removing Changing the Filters You now need to reset the Intelli Check Filter Indicator With the air purifier powered on press and hold the appropriate filter indicator button for approximately 10 seconds until the light turns off see Fig 1 If the HEPA filter clogs or if you have difficulty cleaning the filter please visit us at www kaz com or call us at 1 800 332 1110 Permanent filter life based on ordinary use and care Cleaning and Storage We recommend that you clean the air purifier at least once a month and before extended storage Use only a dry cloth to wipe external surfaces of the air purifier DO NOT USE WATER WAX POLISH OR ANY CHEMICAL SOLUTION If you store your Honeywell HEPA air purifier for more than 30 days we recommend e Removing both the primary HEPA filter and th
3. the filter assembly consisting of the HEPA filter and pre filter from the internal chamber e Locate the seam of the pre filter and carefully separate the fastener to remove the pre filter from the HEPA filter e Discard used pre filter if necessary Clean the HEPA filter if necessary e Replace HEPA Filter there is no top or bottom to filter e Replace top cover e Insert and tighten handle clockwise To Replace Pre filter e Place unit on its side e Push in on both tabs on base ring to release base Fig 3 e Gently remove base from motor assembly Fig 2 Open 4 Close Handle lt Handle ea Filter T Pre filter installed on Base Ring Fig 3 Groove to release X Base Ring e Install initial pre filter or replace used one Wrap pre filter around Base Ring and attach with fastener provided e Align base into grooves and gently snap back into place Cleaning the Lifetime HEPA Permanent Filter The LifeTime HEPA Filter is vacuum able and should be cleaned regularly for optimum performance To Clean the HEPA Filter DO NOT USE WATER OR OTHER LIQUIDS TO CLEAN THE HEPA FILTER Turn the air purifier OFF and unplug from the wall outlet After removing the filter assembly from the air purifier refer to section Removing Changing the Filters in this manual separate and remove the carbon pre filter from the HEPA filter and place aside or discard
4. arranty applies only to the original purchaser of this product from the original date of purchase B At its option Kaz will repair or replace this product if it is found to be defective in material or workmanship Defective product should be returned to the place of purchase in accordance with store policy Thereafter while within the warranty period defective product may be returned to Kaz m This warranty does not cover the pre filter or the HEPA filter except for material or workmanship defects This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use not in accordance with the instruction manual Return defective product to Kaz Incorporated with a brief description of the problem Include proof of purchase and a 10 US 15 50 CAN check or money order for handling return packing and shipping charges Please include your name address and a daytime phone number You must prepay shipping charges Send to In U S A Kaz Incorporated Attn Returns Department 4755 Southpoint Drive Memphis TN 38118 USA In Canada Kaz Incorporated Attn Returns Department 510 Bronte Street South Milton ON LOT 2X6 Canada 2005 Kaz Incorporated All Rights Reserved P N N 0120 Rev 0
5. ction Cleaning the LifeTime HEPA Permanent Filter in this manual When your Pre filter Indicator Light turns on it s time to replace your pre filter It should be replaced at least every 3 months If there are heavy concentrations of odors smoke or large particles in the home you may need to change the carbon pre filter more often For instructions on how to replace your pre filter refer to section Removing Changing the Filters in this manual Note We do not recommend operating the air purifier without the carbon pre filter Reset Filter Indicator Turn Light Off To Reset Filter Indicator e Once the filter has been checked and cleaned or replaced as needed the filter indicator will need to be reset e With the unit powered on press and hold the appropriate filter indicator button down for approximately 10 seconds until the light turns off Fig 1 Removing Changing the Filters INSTALL PRE FILTER BEFORE INITIAL OPERATION The initial pre filter is packaged separately to ensure its freshness BEFORE initial operation locate the pre filter in the box remove it from its packaging and install per instructions below e DISCONNECT from power supply before servicing e Replace filter s and re assemble unit per instructions below e Plug in and RESET appropriate filter monitor s To Remove HEPA Filter for Cleaning e Unscrew handle counter clockwise Fig 2 e Remove top cover e Remove
6. d air is returned to the room Portable air purifiers will be much more effective in rooms where all doors and windows are closed Germ Reduction True 99 97 HEPA Air Purifier with Germ Reduction This air purifier model continually helps clean the air and helps reduce airborne bacteria germs and mold spores by drawing air through the HEPA filter which traps and collects these particulates In a test lab the air purifiers were tested for reducing airborne pathogens that passed through the filter and results indicated a bacterial reduction up to 100 with a mean reduction of 99 3 Handle TOP Cover CONTROL PANEL HEPA Filter HEPA Filter check reset monitor Pre filter check reset monitor Power Button OFF HIGH MED LOW po g Pre filter Base Ring e Select a firm level and flat location For proper air flow locate the unit at least 3 feet 1 meter from any wall or furniture e Due to the large volume of air drawn towards the air purifier surrounding areas should be cleaned and or vacuumed frequently to prevent dust buildup If the unit is placed on light colored carpeting a small mat or rug should be used to ease cleaning and prevent any permanent staining of carpeting This is particularly important in homes with heavier contamination from smoking or fireplaces e Locate pre filter in the box and install befor
7. e activated carbon pre filter from the unit e Discarding the pre filter e Wrapping the HEPA filter in an air tight plastic bag or plastic wrap Be sure that the filter is totally sealed e To restore the air purifier to service unwrap the HEPA filter install a new activated carbon pre filter and reinstall both filters in the air purifier See Removing Changing the Filters section for proper installation Frequently Asked Questions Important this air purifier has been designed to operate very quietly and effectively without a cool exhaust draft especially on lower speeds My Air Purifier is starting to make noise and the air output is less What s wrong The filters may be dirty High amounts of contaminates can block the pores in the filter and stop the air from moving through it Clean the HEPA Filter How long should I run my Air Purifier For best results you should operate your Air Purifier 24 hours a day This unit will be more effective when doors and windows are closed Can I wash the filters No Washing the filters will destroy them Accessories and Replacement Filters To order replacement pre filters visit our website at www kaz com or call us at 1 800 332 1110 Universal Carbon Pre filter 38002 14 99 Consumer Relations Mail questions or comments to Call us toll free at 1 800 332 1110 Kaz Incorporated E mail consumerrelations kaz com Consumer Relations Dept Or visit our website a
8. e initial operation Refer to Removing Changing the Filters section for proper installation INSTALL PRE FILTER BEFORE INITIAL OPERATION Refer to Removing Changing the Filters section for proper installation To encourage operation on higher speeds the Honeywell 18155 air purifier has been designed to operate very quietly and effectively without a cool exhaust draft To operate press the POWER button to HIGH speed for a few seconds and then leave it on high for faster more powerful air circulation or move it to a lower setting as desired Intelli Check Filter Indicators The Intelli Check Filter Indicators serve as a convenient guideline for when to clean the LifeTime HEPA Permanent Filter and when to replace the carbon pre filter Depending upon your individual usage environment and hours used you may need to clean replace the filters more or less frequently When the HEPA Filter Indicator Light turns on it s time to clean your HEPA filter The Intelli Check reminder for when to clean the HEPA filter is intended as a guideline only as the performance of the filter media is dependent on the concentration of the contaminants to which the system is exposed If there are sources of large amounts of contaminant generation such as dust from woodworking or heavy smoking the HEPA filter in your air purifier may need to be cleaned more often For instructions on how to clean your HEPA filter refer to se
9. t www kaz com 250 Turnpike Road Southborough MA 01772 Please be sure to specify a model number NOTE IF YOU EXPERIENCE A PROBLEM PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR WARRANTY DO NOT RETURN TO THE ORIGINAL PLACE OF PURCHASE DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE AIR PURIFIER OR PERSONAL INJURY fl Five Year Limited Warranty C You should first read all instructions before attempting to use this product A This 5 year limited warranty applies to repair or replacement of product found to be defective in material or workmanship This warranty does not apply to damage resulting from commercial abusive unreasonable use or supplemental damage Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you also may have other rights which vary from jurisdiction to jurisdiction This w
10. undry area or other damp location 11 The air purifier must be used in its upright position 12 Do not allow foreign objects to enter ventilation or exhaust opening as this may cause electric shock or damage to the air purifier Do not block air outlets or intakes 13 Locate air purifier near the outlet and avoid using an extension cord 14 This appliance has a polarized plug one blade is wider than the other To reduce the risk of shock this plug is intended to fit only one way in a polarized outlet If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to defeat this safety feature 15 A loose fit between the AC outlet receptacle and plug may cause overheating and a distortion of the plug Contact a qualified electrician to replace loose or worn outlet 16 Do not sit stand or place heavy objects on the air purifier 17 Disconnect power supply before servicing WARNING To Reduce The Risk of Fire or Electric Shock Do Not Use This Air Purifier With Any Solid State Speed Control Device For Best Performance We recommend that you operate your Honeywell air purifier 24 hours a day because indoor air can be quickly contaminated by activity in a room infiltration of outside air and from other sources of contamination While all the air in a room will not be processed by the air purifier the more air circulated through the filter the more filtere
Download Pdf Manuals
Related Search
Related Contents
External Power Bank Suitable For Notebook Sunstech CRUM375IPOD CD radio S7−CPs für PROFIBUS Projektieren und in - Service Philips SPP2307WC Wall tap 6 outlets Surge protector 1 généralités Baumatic BO667TS.DD Format.zip -ES カナロン安全データシート(SDS) Samsung 2232MW User Manual Copyright © All rights reserved.
Failed to retrieve file