Home

Graco Inc. 309489D Paint Sprayer User Manual

image

Contents

1. 1 800 328 0211 Toll Free 612 623 6921 612 378 3505 Fax All written and visual data contained in this document reflects the latest product information available at the time of publication Graco reserves the right to make changes at any time without notice MM 309489 Graco Headquarters Minneapolis International Offices Belgium Korea China Japan GRACO INC P O BOX 1441 MINNEAPOLIS MN 55440 1441 WWW graco com PRINTED IN USA 309489 11 2004 Rev 10 2008 20 309489
2. 39 620985 PACKING washer throat 42 510786 FITTING elbow pipe 43 206078 AIR MOTOR president See manual 306982 for parts 44 100022 SCREW cap hex hd 45 502682 WASHER flat cs 46 237469 VALVE ball heavy duty 47 504134 FITTING tee pipe 48 500084 BUSHING hex hd 49 101754 PLUG pipe 50 158256 UNION swivel 51 504704 FITTING nipple hex 52 190339 TUBE by pass 53 112790 CONNECTOR tube L l L l nnn NM NM o as ann nn nn psp nan nn in un pp Parts included in Repair Kit 946761 309489 Qty A L2 Ad dd dl dl dl yyy 15 Technical Data Fluid pressure Tatio etre lta Pu ber TU metus pen rae ae NU MATRE UIT Ep ess 10 1 Air pressure operating range ca ceasar rana danadana mm 40 180 psi 3 12 bar Maximum fluid working pressure sssssssssssssesse e mn 1800 psi 124 bar Maximum recommended pump speed 0 ccc en 60 cycles minute Delivery continuous duty susas sessa eR Hh hh 3 gpm 12 liter min Delivery intermittent duty 0 0 ccc IRI HH hn 6 gpm 25 io Cycles per gallon liter ooo da XX MENU a NOR AO 20 6 Air motor effective diameter 000s eect en ehh 4 1 4 in 108 mm PUMP Stroke nia eese ate ta Ata ON Lape tert cv ins S Peces 4 in 100 mm Air consumption ssessese eene Approx 13 CFM per gallon 6m3 hr liter of fluid at 100 psi 7 bar Welted parts eem a t m m Fd e ee eR eg Steel Aluminum Brass Leather Buna N 16 309489 Dimens
3. onto the piston body 16 Screw the piston onto the connecting rod 14 and adjust the ball travel as instructed in Check Valve Adjustment below Tighten the locknut 15 11 Check the o ring 11 in the pump base and re place it if necessary 12 Lubricate the piston packings and the inner wall at the top of the riser tube 13 Wrap the packings with a guide collar made of 1 64 in maximum thickness shim stock or metal sheeting Using a turning motion work the first leather packing into the riser tube Remove the guide collar and push the riser tube up and screw it into the base Torque the tube to 100 150 ft lb 135 204 Nem Reassembly 1 Besure the check valves are properly adjusted See below 2 Reinstall the intake valve 3 Reconnect the pump s ground wire to a true earth ground Check Valve Adjustment These pumps have adjustable fluid intake and piston ball checks which are factory set for medium viscosity fluids To change the piston ball travel see Fig 5 loosen the lock nut 15 Turn the piston body 16 counter clockwise to increase and clockwise to decrease Medium viscosity fluids should have a 3 16 in 5 mm ball travel Decreasing the ball travel minimizes surging at stroke changeover but too short a ball travel re stricts the flow and slows down the pump To change the intake valve ball travel move the ball stop pin 24 to a higher or lower set of holes Use the middle holes for medium visc
4. open flames or sparks can cause a hazardous condition and re sult in a fire or explosion and serious injury Ground the equipment and the object being sprayed Refer to Grounding on page 5 If there is any static sparking or you feel an electric shock while using this equipment stop spray ing immediately Do not use the equipment until you identify and correct the problem Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed Keep the spray area free of debris including solvent rags and gasoline Before operating this equipment electrically disconnect all equipment in the spray area Before operating this equipment extinguish all open flames or pilot lights in the spray area Do not smoke in the spray area Do nat turn on or off any light switch in the spray area while spraying or while operating if fumes are present Do not operate a gasoline engine in the spray area Never use 1 1 1 trichloroethane methylene chloride other halogenated hydrocarbon solvents or fluids containing such solvents in this equipment Such use could result in a serious chemical reaction with the possibility of explosion which could cause death serious injury and or substan tial property damage Consult your fluid suppliers to ensure that fluids being used are compatible with aluminum and zinc parts TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if
5. Instructions G GRACO President 10 1 Ratio Air Spray System For transfer or supply of compatible fluids 309489D With Evenflo Automatic Pressure Control Model 954088 Series A 180 psi 12 bar 1 2 MPa Maximum Working Pressure Air Input Related Manuals Evenflo9 Automatic Pressure Control 306479 President Air Motor 306982 PROVEN QUALITY LEADING TECHNOLOGY GRACO INC P O BOX1441 MINNEAPOLIS MN 55440 1441 C Pe Copyright 2003 Graco Inc is registered to I S EN ISO 9001 HOO3 Table of Contents Warnings 3 vai ve erede Re e es 2 Parts Lists and Drawings InstallatlOn iios RRISees TERLIC Repente 5 Model 954088 a r p eee 14 Operation 0 cece ee 8 Technical Data s srnca riedia neras Ciara raens 16 Maintenance 0 cece ees 10 DIMENSIONS ia M hep poate als 17 Troubleshooting cece eee eee 11 Warranty i ccc caer Do See enc eee 20 Displacement Pump Repair 0 12 Graco Information 0 cece eee eee ee 20 Check Valve Adjustment suuuss 12 Symbols Warning Symbol Caution Symbol This symbol alerts you to the possibility of serious This symbol alerts you to the possibility of damage to injury or death if you do not follow the instructions or destruction of equipment if you do not follow the instructions 4 WARNING 0 EQUIPMENT MISUSE HAZARD e Equipment misuse can c
6. ause the equipment to rupture or malfunction and result in serious injury INSTRUCTIONS This equipment is for professional use only Read all instruction manuals tags and labels before operating the equipment Use the equipment only for its intended purpose If you are not sure call your Graco distributor Do not alter or modify this equipment Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment Do not exceed the maximum working pressure of the lowest rated component in your system Use fluids and solvents which are compatible with the equipment wetted parts Refer to the Tech nical Data section of all equipment manuals Read the fluid and solvent manufacturer s warnings Handle hoses carefully Do not pull on hoses to move equipment Route hoses away from traffic areas sharp edges moving parts and hot surfaces Do not expose Graco hoses to temperatures above 66 C 150 F or below 40 C 40 F Wear hearing protection when operating this equipment Do not move or lift pressurized equipment Comply with all applicable local state and national fire electrical and safety regulations 2 309489 4 WARNING INJECTION HAZARD Spray from the gun leaks or ruptured components can inject fluid into your body and cause extremely serious injury including the need for amputation F
7. egulator E to control air to the motor and pump speed An air line filter C removes harmful dirt and moisture from your compressed air supply Be sure that the air supply hose is properly grounded and is at least 1 2 in 13 mm ID in order to supply an adequate volume of air to the motor Connect a suitable grounded fluid hose and spray gun or dispensing valve to the pump s 3 4 in npt outlet Installation Typical Installation KEY Bleed Type Master Air Valve Pump Runaway Valve Air Line Filter Air Line Lubricator Pump Air Regulator p Drain Valve part of 38 Evenflo Valve PE Pump Ground Wire 7 AK Grounded Fluid Hose Z Grounded Air Hose Evenflo Control Knob rear of valve Evenflo Valve By pass Tube gSger crmoou 38 Evenflo Air Regulator 1 2 Minimum ti3003a7 309489 7 Operation Pressure Relief Procedure With the Evenflo control its bypass valve and the pump Relax A Valve properly set fluid pressure is relieved from the pump and hose each time you re lease the gun trigger Always engage the gun trigger safety when you stop spraying To relieve air pressure close the Evenflo regulators and open the bleed type master air valve 44 WARNING INJECTION HAZARD If you suspect that the Evenflo9 system is not properly set or that pressure is not fully relieved the system pressure must be manually relieved to prevent the system from starti
8. ely lower the fluid outlet pressure from the pump Refer to the Technical Data on page 16 for the maximum air and fluid working pressure of this pump To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 Relieve the pressure whenever you stop spraying Always stop the pump at the bottom of its stroke to prevent fluid from drying on the rod and damaging the throat packings If you are pumping fluid which dries hardens or sets up flush the system with a compatible solvent as often as necessary to prevent a build up of dried fluid in the pump or hoses 309489 9 Maintenance Lubrication If your system includes an automatic air line lubricator adjust the lubricator as instructed in the separate instruction manual For manual lubrication each day remove the air inlet hose and place 12 to 15 drops of high quality light motor oil in the inlet Reattach the hose and turn on the air to blow the oil into the motor Throat Packing Adjustment 44 WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 Once a week or after each 40 hours of operation check the tightness of the throat packing nut It should be tight enough to stop leakage but no tighter To check first relieve the pressure Then remove the identification plate M fro
9. henever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 Never operate the pump with the air motor plate Relieve the pressure before you check or service any removed Moving parts in the piston can pinch or System equipment amputate fingers Problem Cause Solution S Pump does not operate or no Loose or broken pump parts Disassemble check repair fluid flow Restricted line or inadequate air sup ply Exhausted fluid supply Refill and prime Clogged fluid hoses Clean or replace Fluid intake or piston valves need Adjust see page 12 adjustment Held open or worn piston or intake Repair see page 12 valve Erratic or accelerated operation Exhausted fluid supply Refill and prime Fluid intake or piston valve worn Repair see page 12 309489 11 Service Displacement Pump Repair Before you start 1 A packing repair kit part no 946761 is available This kit includes two glands and eight packings for the motor as well as o rings packings and wash ers for the displacement pump For the best re sults use all the parts in the kit 2 Clean all parts as you disassemble them using a compatible solvent and inspect for wear or dam age Replace parts as necessary Intake Valve See Fig 4 44 WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 1 Relie
10. ion splashing in the eyes and injury from moving parts if you are adjusting or repairing the pump The bleed type master air valve relieves air trapped between this valve and the pump after the air regulator is shut off Trapped air can cause the pump to cycle unexpectedly Locate the valve close to the pump The fluid drain valve part of the Evenflo air regulator installed on pump assists in relieving fluid pressure in the displacement pump hose and gun triggering the gun to relieve pressure may not be sufficient 6 309489 Evenflo Automatic Pressure Control An Evenflo air regulator installed on the pump has a Relax A Valve This regulator prevents initial surging of non atomized fluid when the gun is triggered Air pressure in the pump is relieved automatically each time the gun trigger is released When used with a Relax A Valve set in the automatic position fluid pressure is relieved automatically also Refer to the Evenflo Automatic Pressure Manual for additional information All Pumps Install the air line accessories in the approximate order shown in the Typical Installation drawing A pump runaway valve B senses when the pump is running too fast and shuts off the air supply to the motor For automatic air motor lubrication install an air line lubri cator D For manual lubrication see Maintenance on page 10 Install the bleed type master air valve A within easy reach of the pump Install an air r
11. ions QR 14 1 2 368 3 mm TI UI oop 3 8 npt 11 16 17 5 mm OD Bottom View 6 1 2 165 1 mm 45 Four 1 4 20 Holes on a 4 1 4 108 mm Dia Bolt Circle 309489 17 Dimensions Model 954088 Series A Weight 40 Ib 18 Kg 4 101 6 mm 3 8 npsm 53 3 4 1365 3 mm E E A Height of 55 gallon ee 422010 drum 34 3 4 883 mm 18 309489 Notes 309489 19 Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use With the exception of any special extended or limited warranty published by Graco Graco will for a period of twelve months from the date of sale repair or replace any part of the equipment determined by Graco to be defective This warranty applies only when the equipment is installed operated and maintained in accordance with Graco s written recommendations This warranty does not cover and Graco shall not be liable for general wear and tear or any malfunction damage or wear caused by faulty installation misapplication abrasion corrosion inadequate or improper maintenance negligence accident tampering or sub stitution of non Graco component parts Nor shall Graco be liable for malfunction damage or wear caused by
12. luid splashed in the eyes or on the skin can also cause serious injury Fluid injected into the skin is a serious injury The injury may look like just a cut but it is a serious injury Get immediate medical attention Do not point the gun at anyone or at any part of the body Do not put your hand or fingers over the spray tip Do not stop or deflect leaks with your hand body glove or rag Do not blow back fluid this is not an air spray system Always have the tip guard and the trigger guard on the gun when spraying Check the gun diffuser operation weekly Refer to the gun manual Be sure the gun trigger safety operates before spraying Lock the gun trigger safety when you stop spraying Follow the Pressure Relief Procedure on page 8 if the spray tip clogs and before cleaning checking or servicing the equipment Tighten all fluid connections before operating the equipment Check the hoses tubes and couplings daily Replace worn damaged or loose parts immediately Permanently coupled hoses cannot be repaired replace the entire hose MOVING PARTS HAZARD Se Moving parts can pinch or amputate your fingers e Keep clear of all moving parts when starting or operating the pump e Before checking or servicing the equipment follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly 309489 3 4 44 WARNING FIRE AND EXPLOSION HAZARD Improper grounding poor ventilation
13. m the motor Using a spanner wrench or a 0 22 in 5 6 mm diameter rod adjust the nut Reinstall the identification plate before operating the pump See Fig 3 Flushing 44 WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 To reduce the risk of injection injury static sparking or splashing in the eyes or on the skin relieve the pres sure Then remove the spray tip spray guns or spray valves only before flushing Hold a metal part of the gun valve firmly to the side of a grounded metal pail and use the lowest possible fluid pressure during flushing 10 309489 CD g M y Sul EE Packing Nut Leather H i Throat Packings 06701 Fig 3 Corrosion Protection 44 WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 44 CAUTION Water or even moist air can cause your pump to corrode To help prevent corrosion never leave the pump filled with water based fluid or air After normal flushing flush the pump again with mineral spirits or oil based solvent and relieve the pressure This leaves the mineral spirits in the pump Troubleshooting A WARNING iE ee He poene aeos 44 WARNING To reduce the risk of serious injury w
14. ng or spraying accidentally Fluid under high pressure can be injected through the skin and cause serious injury To reduce the risk of an injury from injection splashing fluid or moving parts fol low the Pressure Relief Procedure whenever you are instructed to relieve the pressure stop spraying check or service any of the system equipment or install or clean the spray tips 1 Engage the spray gun or dispensing valve safety latch 2 Close the pump air regulator 3 Close the master bleed type air valve required 4 Disengage the gun or dispensing valve safety latch 5 Hold a metal part of the gun valve firmly to a grounded metal waste container and trigger to relieve fluid pressure 6 Engage the safety latch again 7 Insure the Relax A Valve is set in the automatic position If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully relieved after following the steps above very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually then loosen completely Now clear the tip or hose 8 309489 A WARNING Never operate the pump with the air motor plate removed Moving parts in the piston can pinch or amputate fingers Startup 44 WARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure always follow the Pressure Relief Procedure on page 8 The pump was tested in oil and s
15. ome oil was left in the pump to protect it from corrosion if the oil will contaminate the fluid your are pumping flush it out To Start the Pump 1 Close the fluid drain valve H 2 Open the bleed type master air valve A 3 Open the Evenflo control knob M four full turns Fig 2 6412B 4 Holding a metal part of the applicator firmly against the side of a grounded metal pail hold the trigger open while slowly opening the air regulator B While the applicator air is on slowly open the pump air regulator A If the pump does not operate release the trigger and close the control valve M a quarter turn 5 Repeat this process until the pump operates when the applicator is triggered Trigger the applicator until flushing of the oil is complete 6 Gradually adjust the pump and applicator air pressure as needed during normal operation Operation Shutdown and Care of the Pump 44 WARNING Use the air regulator A to control fluid pressure and pump speed Always use the lowest pressure neces sary to get the desired results Higher pressures cause premature pump wear and spray tip wear and usually do not improve the spray pattern 44 WARNING To reduce the risk of overpressurizing your system which could result in component rupture and cause serious injury never exceed the maximum working pressure of the lowest rated component in your system Lowering the air pressure to the motor will proportionat
16. osity fluids ZN Torque to 100 150 ft lb 136 204 Nem Fig 4 2 8 3 16 Piston Ball Travel 19 4 UN 9 1 5 309489 13 14 309489 Parts Model 954088 Series A Includes items 1 53 Ref Ref No Part No Description Qty No Part No Description 1 100016 WASHER lock 29 620835 FITTING nipple pipe 2 621201 STUD clamp 30 621201 STUD clamp 3 510636 PIN spring str 31 946670 CLAMP pipe 4 620850 ROD connecting 32 104137 SCREW binder 10 24 x 3 8 5 620832 CYLINDER pump displacement 33 102790 SCREW machine pan hd 6 620842 STUD throat packing 34 100676 NUT 7 620841 PACKING spacer throat 35 100020 WASHER lock 8 510476 PACKING cup 36 510787 FITTING coupling pipe 9 620840 PACKING nut throat 37 203156 CLAMP pump e 510473 PACKING o ring 11 510472 PACKING o ring 12 946669 HOUSING outlet pump 13 620833 CYLINDER pump disp 10 1 pres 14 620849 ROD connecting 15 101960 NUT 16 620848 HOUSING valve 17 101917 BALL bearing 18 510475 PACKING cup 19 620837 SPACER cup 20 620836 WASHER piston packing 21 620831 SEAT valve 22 154662 PACKING o ring 23 166238 PACKING o ring 24 162947 PIN straight headless 25 101968 BALL bearing 26 186991 HOUSING valve intake 27 164630 RING locking 28 621203 CLAMP tube 38 202844 PRESSURE CONTROL automatic Evenflo See manual 306479 for parts
17. s all implied warranties of merchantability and fitness for a particular purpose in connection with accessories equipment materials or components sold but not manufactured by Graco These items sold but not manufactured by Graco such as electric motors switches hose etc are subject to the warranty if any of their manufacturer Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties In no event will Graco be liable for indirect incidental special or consequential damages resulting from Graco supplying equipment hereunder or the furnishing performance or use of any products or other goods sold hereto whether due to a breach of contract breach of warranty the negligence of Graco or otherwise FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document as well as all documents notices and legal proceedings entered into given or instituted pursuant hereto or relating directly or indirectly hereto be drawn up in English Les parties reconnais sentavoir convenu que la r daction du pr sente document sera en Anglais ainsi que tous documents avis et proc dures judiciaires ex cut s donn s ou intent s la suite de ou en rapport directement ou indirectement avec les procedures concern es Graco Information TO PLACE AN ORDER contact your Graco distributor or call one of the following numbers to identify the distributor closest to you
18. splashed in the eyes or on the skin inhaled or swallowed 309489 Know the specific hazards of the fluid you are using Store hazardous fluid in an approved container Dispose of hazardous fluid according to all local state and national guidelines Always wear protective eyewear gloves clothing and respirator as recommended by the fluid and solvent manufacturer Installation General Information 4 NOTE Reference numbers and letters in parentheses refer to callouts in the Figs and parts drawing 5 NOTE Always use Genuine Graco Parts and Acces 6 sories available from your Graco distributor T Grounding FIRE AND EXPLOSION HAZARD Before operating the pump ground the 8 system as explained below Also read the section FIRE OR EXPLOSION HAZ ARD on page 4 1 Pump use a ground wire and clamp as shown in Fig 1 Loosen the grounding lug locknut W and washer X Insert one end of a 12 ga 1 5 mm minimum ground wire Y into the slot in lug Z and tighten the locknut securely Connect the other end of the wire to a true earth ground Order part number 222011 Grounding Clamp and Wire 2 Air and fluid hoses use only conductive hoses 3 Air compressor follow manufacturer s recommen dations Spray gun or dispensing valve ground through connection to a grounded fluid hose and pump Fluid supply container follow your local code Object being sprayed follow your local code Solvent pails used
19. the incompatibility of Graco equipment with structures accessories equipment or materials not supplied by Graco or the improper design manufacture installation operation or maintenance of structures accessories equipment or materials not supplied by Graco This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect If the claimed defect is verified Graco will repair or replace free of charge any defective parts The equipment will be returned to the original purchaser transportation prepaid Ifinspection of the equipment does notdisclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE Graco s sole obligation and buyer s sole remedy for any breach of warranty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years ofthe date of sale Graco makes no warranty and disclaim
20. ve the pressure 2 Unscrew the intake valve housing 27 3 Remove the ball stop pin 24 Inspect the ball 25 and seat 23 for nicks or scratches 4 Replace the ball and or seat if it is damaged as damaged parts do not seal properly and may cause poor pump performance 5 If no further service is needed reassemble the intake valve Be sure the ball stop pin 24 is reinstalled in the proper holes See Check Valve Adjustment at right Piston 6 Unscrew the riser tube 13 from the pump base Clean the tube and inspect it for wear by holding it up to a light at a slight angle If you see wavy lines or scratches where the piston travels replace the tube as it will not seal well with the new piston packings and the pump will perform poorly 7 Loosen the locknut 15 and unscrew the piston body 16 from the connecting rod 14 8 Disassemble and clean all parts 12 309489 9 Reassemble the piston using all the new parts from the kit and any other new parts needed Oil the leather packings 20 first Then reassemble the parts on the piston seat 21 in this order backup washer 18 leather packing 20 spacer 19 with a new o ring 22 installed on it another leather packing 20 and backup washer 18 NOTE To replace the throat packings follow the steps given in your separate air motor manual supplied before continuing with this procedure 10 Apply sealant to the threads of the seat 21 and screw
21. when flushing follow your local code Use only conductive metal pails placed on a grounded surface Do not place the pail on a nonconductive surface such as paper or card board which interrupts the grounding continuity To maintain grounding continuity when flushing or relieving pressure hold a metal part of the spray gun firmly to the side of a grounded metal pail then trigger the gun Fig 1 Ww Si 309489 5 Installation NOTE Reference numbers and letters in parentheses in the text refer to callouts in the figure illustrations and the parts drawing The Typical installation shown on page 7 is only a guide to electing and installing required and optional accessories For assistance in designing a system to Suit your needs contact your Graco representative Mount the pump to suit the type of installation planned The pump dimensions and mounting hole layout are shown on page 17 Pail and Drum Length Pumps Install the pump in the drum or pail using a suitable cover bung adapter or mounting clamp The pump must be 1 2 in 13 mm off the bottom of the pail or drum The pump has a by pass tube route the tube back to the supply container NOTE In a closed head drum be sure to loosen the vent plug in the drum cover to prevent formation of a vacuum 44 WARNING An accessory is required in your system a bleed type master air valve A This accessory helps reduce the risk of serious injury including inject