Home
GE GXSF30H Water System User Manual
Contents
1. 02 Pb Eb PRPRPRPRPUOPRPRPRPENNMPRPRPRPRPRPRPRP ge com 25 Parts catalog 26 GENERAL ELECTRIC PARTS CATALOG REF NO 0111 0112 0113 0114 0115 0116 0117 0118 0119 0120 0121 0122 0123 0124 0130 0132 0133 0134 0135 0136 0137 0138 0139 0140 0141 0143 0145 0146 0147 0150 0151 0152 0999 NOTE Codes in the State of Massachusetts require installation by a licensed PART NO WS19x10005 WS03x10013 WS22X10020 WS08xX10005 WS03X10015 WS22x10021 WS03x1001 WS15xX1003 WS03X1001 WS03X10019 WS15xX1001 WS03X10020 WS22x10022 WS15xX10009 WS35xX10005 WS22x10023 WS03x10021 WS03x10022 WS03X10023 WS26xX10003 WS26xX10004 WS26xX10005 WS02x10015 WS26x10011 WS02x10016 WS60x10013 WS60X10004 WS28xX10017 WS19X10006 WS03X10024 WS15xX10053 WS03X10025 49 50177 WS60x10014 0 o PART DESCRIPTION SUPPORT SCREEN SCREEN FLOW PLUG 10 GPM GASKET amp ASPIRATOR CONE SCREEN PLUG FILL FLOW 30 GPM FERRULE NUT NOZZLE VENTURI BODY RETAINER SEAL O RING 1 4 x 3 8 BODY VALVE SPRING PLUG DRAIN SEAL NOZZLE VENTURI ASM SEAL KIT 3 4 ADAPTER DRAIN HOSE O RING 5 8 X 13 16 LUG FLOW RINSE CONTROL LIP AM amp GEAR EARING LATE MOTOR 3 4 CREW 6 20 X 3 8 OTOR ASM CREW 6 20 X 7 8 DAPTER NPT THREADED STD VALVE LIP HARNESS WIRE SENSOR ASSY 3 4 TU
2. 29 ge com Cat logo de partes CAT LOGO DE PARTES DE GENERAL ELECTRIC 56 NO REFER 0003 0004 0005 0030 0031 0032 0033 0034 0035 0036 0037 0038 0039 0055 0056 0101 0102 NO DE PARTE WS35X10001 WS34X10015 WS07X10004 WS14X10002 WS14X10001 WS01X10002 WS32X10011 WS31X10022 WS31X10023 WS21X10017 WS26xX10013 WS31X10021 WS33X10001 WS33X10007 WS31X10024 WS02X10009 WS32X10017 WS02X10027 WS32X10016 WS18X10003 WS22X10016 WS22X10017 WS35X10035 WS15X10035 WS35X10036 WS03X10006 WS15X10006 WS03X10007 WS03X10008 WS07X10002 WS07X10015 WS31X10018 WS02X10029 WS02X10030 WS28X10003 WS28X10004 WS02x10012 502 10013 DESCRIPCI N DE LA PARTE KIT DEL SELLO DEL ARO T RICO ETIQUETA PLACA FRONTAL MANGUERA DE DRENAJE 20 PIES DISTRIBUIDOR SUPERIOR DISTRIBUIDOR DE BAJO RESINA 1 PIE C BICO TANQUE DE RESINA 9 X 40 CUBIERTA SUPERIOR CON LENTES PLATO FRONTAL CONTROL TRANSFORMADOR CON CABLE EL CTRICO CUBIERTA AGUJERO DE LA SAL CON ETIQUETAS BARRERA DE VAPOR BORDE CUBIERTA DEP SITO DE LA SALMUERA CON ETIQUETA TUERCA DEP SITO DE LA SALMUERA CON ETIQUETA TORNILLO TANQUE DE SALMUERA REDONDO ABRAZADERA DE LA MANGUERA ADAPTADOR DE LA MANGUERA ARANDELA DE GOMA KIT DE ABRAZADERAS PARA CONEXI N A TIERRA ENSAMBLADURA DE LA V LVULA DE LA SALMUERA ENSAMBLADURA DE FLOTE PALANCA Y GU
3. Ten Years A replacement brine tank or cabinet if either fails due to a defect in materials or workmanship From the date of the During this ten year limited warranty you will be responsible for any labor or related service costs original purchase What Is Not Covered E Service trips to your home to teach you how to use E Replacement of house fuses or resetting of circuit breakers the predict E Damage to the product caused by accident fire floods or E improper installation delivery or maintenance acts of God E Failure of the product if it is abused misused altered used E Incidental or consequential damage caused by possible commercially or used for other than the intended purpose defects with this appliance its installation or repair E Use of this product where water is microbiologically unsafe E Product not accessible to provide required service or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied warranties of merchantability or fitness for a particular purpose are limited to one year or the shortest period allowed by law This warranty is extended to the original purchaser and any succeeding owner for products purchased for
4. A CLIP CUERPO DE LA V LVULA SALMUERA CLIP FILTRO ENSAMBLADURA DE LA TUBER A ENSAMBLADURA DE LA TUBER A DE LA SALMUERA CUBIERTA POSTERIOR SIST ELECTR NICOS ESPACIADOR SOPORTE PLACA FRONTAL ABRAZADERA RETENEDORA ABRAZADERA TORNILLO ESPACIADOR NOTA los c digos del Estado de Massachusetts requieren que un fontanero con licencia realice la instalaci n y no permiten el uso de una v lvula de asiento Para la instalaci n utilice el c digo de fontaner a 248 CMR del Commonwealth de Massachusetts ION nun X 02 he ererer e PRPRPRPRPRPRPPRPP PRPRPNMRPP PRPRPRPPP PP Perenne CAT LOGO DE PARTES DE GENERAL ELECTRIC NO REFER 0103 0104 0147 0150 0151 0152 0999 NOTA los c digos del Estado de Massachusetts requieren que un fontanero con licencia realice la instalaci n y no permiten el uso de una v lvula de asiento Para la instalaci n utilice el c digo de fontaner a DE PARTE WS21X10003 WS03X10009 WS02x10014 WS31X10006 WS03X10010 WS26xX10002 WS19X10004 WS03x10011 WS19X10005 WS03X1001 WS22x10020 WS08x10005 WS03x10015 WS22x10021 WS03x10017 WS15xX1003 WS03X10018 WS03X10019 WS15xX10010 WS03X10020 WS22x10022 WS15X10009 WN D WS35X10005 WS22X10023 WS03X10021 WS03X10022 WS03x10023 WS26xX10003 WS26xX10004 WS26xX10005 WS02x10015 WS26xX10011 WS02x10016 WS60x10013 WS60xX10004 WS28xX10017 WS19X10006 WS03X10024 WS15xX10053 WS03X1
5. Aros t ricos El sello del aro t rico va en la muesca externa solamente El clip engrapa en la muesca interna ver m s adelante e Enganche los dos clips pl sticos en sus posiciones a partir de la parte superior y hacia abajo como se muestra Clip VISTA LATERAL VISTA POSTERIOR V lvula de bypass Cuerpo de la emp jela al m ximo v lvula de entrada o salida e Empuje los adaptadores NPT lubrique los aros toricos con grasa de silicona en ambas entradas de la v lvula como se muestra e Asegure los dos clips pl sticos grandes en su lugar lateralmente como se muestra MUEVA LA ENSAMBLADURA DEL DESCALCIFICADOR HACIA SU POSICION DE INSTALACION Antes de deslizar el descalcificador a su lugar cerci rese de que la superficie de instalaci n se encuentre nivelada y lisa Cualquier objeto cortante debajo del tanque podr a causar una hendidura en el mismo Si es necesario coloque el tanque sobre una secci n de plywood de un grueso m ximo de 1 91 cm 3 47 Luego coloque cu as debajo del plywood seg n sea necesario para nivelar el descalcificador Deslice el descalcificador a su lugar Instrucciones de instalaci n 3 CONECTE LAS TUBER AS QUE ENTRAN Y SALEN DEL DESCALCIFICADOR APRECAUCI N Siga todas las precauciones siguientes mientras conecta la plomer a de entrada y salida Vea la ilustraci n de instalaci n normal o CERCIORESE DE QUE EL SUMINISTRO DE AGUA DURA
6. Installation Instructions Water Softening System Model GXSF30H A WARN Read entire manual Failure to follow all guides and rules could cause personal injury or property damage Check with your state and or local public works department for plumbing codes You must follow their guides as you install the Water Softening system NOTE Failure to comply with these installation instructions will void the product warranty and the installer will be responsible for any service repair or damages caused thereby BEFORE BEGINNING INSTALLATION Read these instructions completely and carefully IM PO RTANT Save these instructions for local inspector s use IMPORTANT observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions for future reference Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty A shutoff valve must be available or added near the installation point IMPORTANT INSTALLATION RECOMMENDATIONS In the Commonwealth of Massachusetts Plumbing Code 248 CMR shall be adhered to Consult with your licensed plumber Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Connect the softener to the main water supply pipe before or ahead of the water he
7. Possible Causes Unit not sanitized Low water pressure Restricted drain hose Unit was idle for a period of time Cracked distributor Running water from the unit into a drain during recharge Air in system after installation Wiring may have worked loose in the control What To Do Complete the Sanitization Procedures on page 12 e At completion of recharge cycle approx 2 hrs run water from faucets to purge the salty water Check pressure Drain height 8 or less pressure should be minimum of 20 psi Drain height above 8 pressure should be minimum of 50 psi Clean and reconnect hose Check for kinks in drain line e Complete the Sanitization Procedures on page 12 Call for service e This is normal e Will go away after it runs for a while See page 16 for details Unplug transformer Remove control cover release clips on side e Check for loose incorrect wiring connections to electronic board or switch Reconnect as required e Reassemble control cover e Plug in Transformer e Wait six minutes for Error Code to reappear e If Error Code reappears call for service Parts list ge com To YN 56 RS ZN 29 Parts list 106 Parts catalog GENERAL ELECTRIC PARTS CATALOG NOTE Codes in the State of Massachusetts require i
8. You may also mail in the pre printed registration card included in the packing material or detach and use the form in this Owner s Manual Printed in the United States
9. correcta Cerci rese de que los agujeros en la junta est n centrados sobre los agujeros en el alojamiento Complete los Procedimientos de desinfecci n de la p gina 40 Despu s de que el ciclo de regeneraci n haya sido completado aproximadamente 2 horas haga circular agua a trav s de los grifos para purgar el agua salada Inspeccione la presi n e Para altura del drenaje de 8 o menor la presi n deber a ser de un m nimo de 20 psi Para altura de drenaje superior de 8 la presi n deber a ser de un m nimo de 50 psi e Limpie y reconecte la manguera Revise en busca de giros en la linea de drenaje Complete los Procedimientos de desinfecci n de la p gina 40 e Llame para solicitar servicio Esto es normal Esto desaparecer despu s de haber funcionado un tiempo Consulte la p gina 45 para detalles Desconecte el transformador Remueva la tapa del control libere los clips en los costados e Inspeccione en b squeda de conexiones sueltas incorrectas de cables hacia los tableros electr nicos o interruptores Vuelva a conectar seg n sea necesario Reensamble la tapa del control Conecte el transformador Espere seis minutos para que el error de c digo desaparezca Si el error de c digo no desaparece llame para solicitar servicio 51 Notas Notas ge com 53 Lista de partes To YN 56 RS ZN
10. la sal al sistema Use una de las funciones siguientes para comenzar una recarga inmediatamente o en el pr ximo inicio de recarga preprogramada Funci n Memoria Si el suministro el ctrico del sistema de descalcificaci n de agua es interrumpido la pantalla de control estar en blanco y la luz indicadora azul se apaga pero el control mantiene la hora correcta por seis horas aproximadamente Cuando el suministro es restaurado usted tendr que reajustar la hora actual solamente si la visualizaci n y la luz indicadora azul est n intermitentes Todos los otros ajustes se mantienen y nunca requieren ser ajustados a no ser que usted desee hacer alg n cambio RECARGUE ESTA NOCHE Oprima no sostenga oprimido el bot n de RECHARGE recarga 9 RECHARGE TONIGHT recargue esta noche comienza a parpadear en el rea de la pantalla de control Una recarga ocurrir en el pr ximo inicio de recarga preprogramada Si decide cancelar esta regeneraci n toque el mismo bot n una vez m s RECARGUE AHORA Oprima y sostenga oprimido el bot n de RECHARGE recarga 69 hasta que RECHARGE NOW recargue ahora comience a parpadear en la pantalla de control El sistema de descalcificaci n de agua comienza una recarga inmediata y cuando termine en unas dos horas usted tendr un nuevo suministro de agua descalcificada Una vez haya iniciado usted no puede cancelar la recarga Si la hora est intermitente despu s de una
11. n siga los procedimientos de desinfecci n siguientes En la f brica se siguen los cuidados para mantener el descalcificador de agua limpio y desinfectado Los materiales usados para construir el descalcificador no contaminar n ni infectar n su suministro de agua ni causar n que se forme o crezca bacteria Sin embargo durante el env o el almacenamiento la instalaci n y la operaci n alg n tipo de bacteria podr a penetrar el descalcificador Por esta raz n el siguiente proceso de desinfecci n se sugiere despu s de la instalaci n NOTA La desinfecci n es recomendada por la Asociaci n de Calidad del Agua 1 Cerci rese de completar todos los pasos de instalaci n incluyendo la programaci n del control 2 Vac e aproximadamente 3 4 de onza de cloro casero 5 25 Clorox Linco Bo Peep White Sail Eagle etc en la salmuera Consulte la ilustraci n en la pagina 33 3 IMPORTANTE Oprima y sostenga oprimido por 3 segundos el bot n RECHARGE recarga 69 del plato para comenzar una recarga inmediata El indicador de RECHARGE recarga aparece intermitente en la pantalla El cloro es llevado a Especificaciones Dimensiones trav s del descalcificador de agua Este proceso dura aproximadamente 2 horas 4 Si despu s de la desinfecci n el agua de la llave de la casa tiene un sabor salado o tiene un color ligero esto es un preservativo del tanque de resina Abra los grifos de agua fr a descalcificada po
12. point An air gap prevents possible siphoning of sewer water into the softener if the sewer should back up Installation Instructions 4 CONNECT AND RUN THE VALVE DRAIN HOSE CONT e Elevating the drain hose may cause back pressure that could reduce the brine draw during recharge If raising the drain line overhead is required to get to the drain point measure the inlet water pressure to the softener first For inlet pressures between 20 and 50 psi do not raise higher than 8 above the floor For inlet pressure above 50 psi the drain line may be raised to a maximum height of 14 Blue indicator light a Ra Valve drain hose Clamp NS Drain fitting on valve LAUNDRY TUB NA Tie or FUND wire ASA hose in a place SUMP i A o air gap FLOOR DRAIN se CONNECTING A RIGID VALVE DRAIN TUBE To adapt a copper drain tube to the softener use a hacksaw to cut the barbed end from the drain fitting as shown Rotate the drain fitting so the cutting blade clears the valve housing to prevent damage to valve Buy a compression fitting 1 4 female pipe thread x 1 2 O D tube and needed tubing from your local hardware store 1 4 NPT threads i vas 1 2 O D copper Co not Tegl Cut from ES drain fitting Compression fitting 1 4 NPT x 1 2 O D tube not provided INSTALL THE BRINE TANK OVERFLOW FITTINGS AND HOSE e Insert the rubber
13. se formar an Antes de llamar para solicitar servicio ge com Problema No hay agua descalcificada Consejos para la identificaci n y soluci n de aver as Ahorre tiempo y dinero Revise la tabla en esta p gina primero y quiz s no tenga que llamar para solicitar servicio NO HAY AGUA DESCALCIFICADA Problemas m s comunes Inspeccione lo siguiente antes de llamar para solicitar servicio e No hay suficiente sal debe estar por lo menos lleno hasta 1 3 e La v lvula de bypass est en la posici n de Bypass el indicador debe estar en la posici n OUT servicio e El ajuste de dureza es demasiado bajo Inspeccione el ajuste de la dureza y aj stelo Verifique la dureza del suministro de agua llamando a su compa a de agua local haciendo pruebas al agua o llamando al Centro de Respuestas de GE e Puente de sal la sal se solidifica por encima del nivel del agua de forma tal que la salmuera no est en contacto con la sal Ver la secci n C mo romper un puente de sal Posible causa Qu hacer El grifo o el accesorio donde la muestra e Para conservar sal el instalador puede que haya aislado algunos fue tomada no est conectado al sistema grifos grifos fuera de la casa inodoros etc del sistema de de agua descalcificada NOTA Cerci rese de descalcificaci n A partir de la salida del sistema de descalcificaci n que la muestra no es tomada de un grifo de agua rastree la trayectoria de
14. DE ENTRADA ESTE DIRECTAMENTE CONECTADO AL PUERTO DE ENTRADA DE LA VALVULA DEL DESCALCIFICADOR Si el flujo del agua de la casa viene desde la izquierda use una v a de enlace de plomer a como se muestra en la ilustraci n de instalaci n normal Si el agua de la casa fluye hacia arriba desde el piso de la casa voltee la v lvula de bypass boca abajo como se muestra Gire la v lvula de bypass boca arriba para conectar a la tuber a al nivel del piso t SALIDA ENTRADA e Manteniendo el descalcificador en su lugar determine la longitud correcta de la tuber a necesaria para conectar las tuber as de su hogar al adaptador macho NPT e Retire el descalcificador del lugar de instalaci n e Si se dispone a llevar a cabo una instalaci n con soldadura de cobre haga todas las soldaduras de condensaci n antes de conectar los tubos a los adaptadores NPT y a la v lvula de bypass El calor de antorcha da ar las partes pl sticas e Cuando se encuentre girando accesorios de tuber a roscados en accesorios pl sticos cerci rese de no cruzar las roscas e Use la cinta de tefl n en todas las roscas externos e Apoye la tuber a de entrada y de salida de alguna manera use colgadores de tuber a para evitar que el peso se deposite sobre los ajustes de las v lvulas e Deslice el descalcificador nuevamente a su lugar e Realice las conexiones finales a la v lvula de bypass y asegure los clips en su lugar Compruebe que
15. adelante enfrente del sensor Usted debe recibir una indicaci n en la pantalla Si recibe una indicaci n desconecte el suministro de agua desconecte la tuber a de entrada y salida e inspeccione la turbina en b squedade agarrotamiento B La letra P y los guiones indican la POSICI N del interruptor de operaci n Si la letra aparece significa que el interruptor est cerrado si los guiones aparecen significa que el interruptor est abierto Use el bot n de RECHARGE recarga RECHARGE TONIGHT RECHARGE NOW Recargue esta noche Recargue ahora para avanzar manualmente la v lvula hacia cada ciclo e inspeccione la correcta operaci n de cada interruptor EL INTERRUPTOR ESTADO DEL CICLO CORRECTO MUESTRA DE LA VALVULA Posici n de v lvula en servicio llenado proceso de salado lavado regresivo o enjuague r pido La v lvula est rotando de una posici n a la otra 46 2 Oprima el bot n MODE modo y C Mientras est en la pantalla de diagn stico la siguiente informaci n est disponible y podr a ser beneficiosa por varias razones Esta informaci n es retenida por la computadora la primera vez que la energ a el ctrica es proporcionada al control Oprima y sostenga oprimido el bot n UP hacia arriba para visualizar el n mero de d as que el control ha tenido la energ a el ctrica aplicada Oprima y sostenga oprimido el bot n DOWN hacia abajo para visualizar el n mero de regeneraciones inicia
16. and you may run out of soft water before the next recharge The system ran out of salt Use one of the following features to start a recharge immediately or at the next preset recharge start time Feature Memory If electrical power to the water softening system is interrupted the control display is blank and the blue indicator light is off but the control keeps correct time for about 6 hours When power is restored you have to reset the present time only if the display and blue indicator light are flashing All other settings are maintained and never require resetting unless a change is desired ge com RECHARGE TONIGHT Touch do not hold the RECHARGE button RECHARGE TONIGHT flashes in the control display area A recharge will occur at the next preset recharge start time If you decide to cancel this recharge touch the same button once more RECHARGE NOW Press and hold the RECHARGE button until RECHARGE NOW starts to flash in the control display area The water softening system begins an immediate recharge and when over in about two hours you will have a new supply of soft water Once started you cannot cancel this recharge If the time is flashing after a long power outage the water softening system continues to work as it should to provide you with soft water However recharge may occur at the wrong time of day until you reset the control to the correct time of day Feature Service Automatic Ele
17. correctamente y colocarse de acuerdo a las Instrucciones de instalaci n antes de su uso Instale o almacene donde no quede expuesto a temperaturas por debajo del punto de congelaci n ni est expuesto a ning n tipo de inclemencias atmosf ricas Si el agua llega a congelarse dentro del sistema ste podr a romperse No intente dar tratamiento al agua si se encuentra a una temperatura por encima de 38 C 100 F 125 psi Si la presi n durante el d a es por encima de 80 psi la presi n nocturna podr a exceder el m ximo Use una v lvula reductora de presi n para reducir el flujo si es necesario Las resinas de descalcificaci n podr an degradarse ante la presencia de cloro por encima de 2 ppm Si usted tiene una cantidad de cloro mayor a sta quiz s experimente una vida menor de la resina En estas condiciones es posible que quiera considerar la compra de un sistema de filtraci n del punto de admisi n para casas GE con un filtro reductor de cloro A ADVERTENCIA beseche todas las partes y los materiales de embalaje no utilizados despu s de la instalaci n Partes peque as restantes despu s de la instalaci n podr an representar un peligro de asfixia No instale expuesto a los rayos directos del sol Exposici n al sol a calor excesivos podr an causar distorsi n u otros da os a las partes no met licas Conecte a tierra de manera apropiada seg n los c digos y ordenanzas aplicables Use solamente fund
18. de 5 en 5 25 30 35 Mantener un bot n presionado hace que los n meros cambien a un ritmo m s r pido HARDNESS Instrucciones de instalaci n AJUSTE EL NIVEL DE DUREZA DEL AGUA CONT 3 Cuando la pantalla muestre el nivel de dureza del agua deseado en granos por gal n oprima MODE modo para aceptar NOTA Si hay hierro de agua clara en su suministro de agua deber aumentar el nivel de dureza en 5 por cada 1 ppm de hierro de agua clara en su suministro de agua Usted puede obtener la dureza de granos por gal n gpg de su suministro de agua a trav s de un laboratorio de an lisis de agua Si recibe el suministro municipal llame a la compa a local de suministro de agua O bien llame al Legend Technical Services un laboratorio independiente para ordenar el kit de prueba de la dureza del agua al 1 800 949 8220 opci n 4 Si su informe muestra dureza en partes por mill n ppm o milogramos por litros mg l simplemente divida por 17 1 para obtener el n mero equivalente de granos por gal n AJUSTE LA HORA DE INICIO DE RECARGA 1 Presione el bot n MODE modo hasta een que RECHARGE TIME hora de recarga ou F se visualice RECHARGE NOTA La hora 2 00 AM intermitente predeterminado en f brica debe aparecer en la pantalla Esta es una buena hora para que la regeneraci n comience toma alrededor de 2 horas en la mayor a de las casas porque el agua no est en uso El AGUA DURA es circ
19. display with faucet open pull the sensor from the valve outlet port Pass a small magnet back and forth in front of the sensor You should get a reading in the display If you get a reading shut off water supply unhook the in and out plumbing and check the turbine for binding B The letter P and dashles indicate POSITION switch operation The letter appearing means the switch is closed the dash means the switch is open Use the RECHARGE 9 RECHARGE TONIGHT RECHARGE NOW button to manually advance the valve into each cycle and check correct switch operation CORRECT SWITCH DISPLAYS VALVE CYCLE STATUS Valve in service fill brining backwash or fast rinse position Valve rotating from one position to another ge com C While in this diagnostic screen the following information is available and may be beneficial for various reasons This information is retained by the computer from the first time electrical power is applied to the control Press and hold the UP button to display the number of days this control has had electrical power applied Press and hold the DOWN button to display the number of regenerations initiated by this control since the SR code number was entered 2 Press the MODE button and hold in three a seconds until a Service Rating code 1 K y For correct water softening system operation the model code must be F30 for model GXSF30H appears in the display To reset the code press the U
20. grommet into the 3 4 diameter hole in the brine tank sidewall as shown Push the end of the hose adapter elbow into the grommet as shown e Attach a length of hose use remaining hose from Step 4 to the hose adapter elbow Use a hose clamp to hold it in place e Locate the other end of the hose at the drain point DO NOT ELEVATE this hose higher than the elbow on the brine tank IMPORTANT DO NOT TEE OVERFLOW HOSE TO VALVE DRAIN HOSE NOTE This drain is for safety only If the cabinet brine tank should over fill with water the excess is carried to the drain Hose adapter Grommet Do not connect to valve drain hose Overflow gt drain hose Na To acceptable drain Installation Instructions 6 INSTALL GROUNDING CLAMP ADANG ER Failure to properly attach ground clamp could result in electrical shock If plumbing is metal to maintain electrical ground continuity in the house cold water piping install the included ground clamp as shown e Clean pipe with emery paper in the area where the clamp is to be installed e Install grounding clamps as shown making sure clamps fit freely around pipe e Make sure lock washer is in place e Handtighten screw then one more full turn with screwdriver NOTE When replacing an existing softener also replace grounding clamps If removing softener completely hard plumb the water line with same type of pipes as the
21. home use within Canada In home warranty service will be provided in areas where it is available and deemed reasonable by Mabe to provide WARRANTOR IS NOT RESPONSIBLE FOR CONSEQUENTIAL DAMAGES Warrantor MABE CANADA INC 28 Informaci n de seguridad 30 Instrucciones de instalaci n 31 40 Instrucciones paso por paso 34 40 Instrucciones de operaci n C mo limpiar la ensambladura de la boquilla y el Venturi 43 C mo romper un puente de sal 42 FUNCIONES ds gado e 44 SOPVICIO vais cacas 41 44 47 Sistema de descalcificaci n 2 A 41 47 Cuidado y limpieza 48 Consejos para la soluci n de aver as 49 51 Soporte al cliente o PA 58 Lista de partes cat logo 54 57 Soporte al consumidor 59 Escriba aqu los n meros de modelo y de la serie Modelo No Serie No Para encontrar estos n meros levante la cubierta y mire en el borde debajo del panel del control 29 INFORMACI N IMPORTANTE DE SEGURIDAD LEA TODAS LAS INSTRUCCIONES ANTES DEL USO A ADVERTENCIA Por su seguridad se debe seguir la informaci n en este manual con el fin de reducir el riesgo de una descarga el ctrica da os a la propiedad o da os personales Ny Via PRECAUCIONES DE SEGURIDAD Revise y cumpla con todos los c digos estatales y Utilice nicamente sales para descalcificaci n locales Observe las pautas aqu
22. la formaci n de puentes de sal consulte la p gina 42 Nunca permita que el sistema de descalcificaci n use toda la sal antes de rellenar el tanque Sin sal pronto dejar de tener agua descalcificada Utilice sales de sistemas de descalcificaci n de agua solamente por lo menos 99 5 puras Recomendamos PEPITAS BOLITAS o SAL GRUESA SOLAR No use sal en roca en bloques granulada ni de helado para descongelar hielo stas contienen suciedad y sedimentos o pasta y masa y crear n problemas de mantenimiento A PRECAUCI N Sal descalcificadora de agua con aditivos que remueven el hierro Algunas sales podr an tener aditivos para ayudar al sistema de descalcificaci n de agua con el hierro en el suministro de agua Aunque este aditivo puede ayudar a mantener limpio el sistema de descalcificaci n de agua el mismo tambi n puede crear gases corrosivos que debilitan y acortan la vida de las partes del sistema de descalcificaci n de agua GE solamente recomienda el uso de la marca de sal Diamond Crystal RedeOut C mo limpiar el hierro de su sistema de descalcificaci n de agua Su sistema de descalcificaci n de agua toma la dureza de los materiales calcio y magnesio y la extrae del agua Tambi n puede controlar una cantidad considerable del hierro del agua clara Consulte la secci n Directrices de especificaciones Con hierro de agua clara el agua de un grifo es clara cuando se coloca en un vaso al pri
23. la parte posterior de la cubierta superior y rote la cubierta hacia arriba para remover NO TIRE O DESCONECTE LOS ALAMBRES e El descalcificador funciona con suministro el ctrico de 24 voltios 60 Hz El transformador incluido cambia de 120 voltios AC normal en las residencias a 24 voltios Conecte el transformador en un tomacorriente de 120 voltios solamente Cerci rese de que el tomacorriente siempre tenga suministro el ctrico y que no vaya a ser desconectado accidentalmente e Reemplace la cubierta superior e Reemplace la cubierta del agujero de sal PROGRAMACI N DEL CONTROL PROGRAMACI N DEL CONTROL Es necesario volver a AJUSTAR LOS CONTROLES despu s de la instalaci n y despu s de una suspensi n prolongada en el suministro el ctrico NOTAS e CUANDO EL TRANSFORMADOR SE CONECTA EN EL TOMACORRIENTE la hora 12 00 aparecer intermitente y PRESENT TIME hora actual se visualice Programe el control seg n las instrucciones a continuaci n Si aparecen unas l neas intermitentes 4K use el bot n UP A para ajustar el c digo del modelo correcto de la siguiente forma siguiente F30 para GXSF30H Si se le pasa el c digo correcto use el bot n DOWN Y Luego oprima el bot n MODE modo para aceptar el modelo correcto e Un bip sonar mientras usted oprime los botones para la programaci n del control Un bip significa un cambio en la pantalla de control Sonidos repetidos significan qu
24. los clips para la v lvula de bypass y los adaptadores NPT se aseguran en su lugar Jale la v lvula de bypass y los adaptadores NPT para verificar que las piezas se mantienen seguras en su lugar 35 CONECTE Y HAGA FUNCIONAR LA MANGUERA DE DRENAJE DE LA VALVULA e Use la manguera de drenaje se ha incluido una de 20 pies para adherirla al accesorio de drenaje de la v lvula Para evitar que la presi n del agua expulse la manguera use la abrazadera de resorte provista para asegurarla en su lugar Corte la longitud necesaria y use la parte restante en el Paso 5 e Ubique el otro extremo de la manguera en un punto apropiado para drenar drenaje de piso sumidero tina de lavander a etc que termine en el sistema de alcantarillado Cerci rese de cumplir con los c digos locales IMPORTANTE Si necesita m s manguera de drenaje ord nela llamando al Departamento de Partes de GE al 800 626 2002 no de parte WS07X10004 El descalcificador de agua no funciona si el agua no escapa por esta manguera durante las regeneraciones Ate o amarre la manguera en un lugar cercano al punto de drenaje Una alta presi n de agua podr a causar que el extremo de la manguera se mueva err ticamente durante los ciclos de lavado regresivo y enjuague r pido de la regeneraci n Tambi n deje una tolerancia de aire de al menos 1 1 2 3 81 cm entre el extremo de la manguera y el punto de drenaje Este espacio previene que ocurra un
25. presentadas Tenga cuidado al manipular el sistema de descalcificaci n de agua No lo voltee deje caer arrastre o coloque en protuberancias extremas Los sistemas de descalcificaci n de agua que utilicen cloruro de sodio sal para la recarga agregan sodio al agua Las personas que siguen dietas con restricciones de sodio deben considerar el sodio adicional como parte de su consumo general El cloruro de potasio del agua al menos con 99 5 de pureza Se recomiendan las sales en PEPITAS BOLITAS O SAL GRUESA SOLAR No utilice sales en roca bloque granuladas o sales para la elaboraci n de helados stas pueden contener suciedad y sedimentos o pasta y masa y podr an crear problemas de mantenimiento Mantenga la tapa del orificio de la sal en su lugar en el descalcificador a menos que est realizando mantenimiento o reponiendo la sal A ADVERTENCIA no use con agua que sea microbiol gicamente insegura o de calidad desconocida sin llevar a cabo la desinfecci n adecuada antes o despu s del sistema puede servir como una alternativa para el cloruro de sodio de su descalcificador El sistema de descalcificaci n de agua funciona solamente con 24 voltios 60 Hz Cerci rese de usar exclusivamente el transformador incluido El transformador se debe conectar nicamente a un tomacorriente interior con conexi n a tierra de 120 voltios 9 INSTALACI N CORRECTA Este sistema de descalcificaci n de agua debe instalarse
26. prolongar el tiempo entre los ciclos de recarga lo que ofrece el uso m s eficiente del agua pero puede usar m s sal El grado de diferencia entre estos dos ciclos depende en gran medida del uso del agua y de la dureza en una instalaci n en particular NOTA La regulaci n de California exige que esta funci n est en la posici n de encendido ON para instalaciones en California Para lograr acceso a la eficiencia de sal presione y sostenga el bot n MODE por tres segundos La pantalla del sistema de diagn stico aparecer Presione el bot n MODE otra vez y la pantalla de eficiencia de sal aparecer Para cambiar este nivel presione los botones UP A o DOWN para fijar la funci n en encendido o apagado ON o bien OFF Presione el bot n MODE modo para aceptar SE ALES DE ERROR Si se detecta un c digo de error la pantalla muestra Err para se alar que el descalcificador necesita mantenimiento Consulte la p gina 45 para informaci n sobre la soluci n de aver as con los c digos de error Una vez que corrija el problema desconecte por un momento el transformador del tomacorriente y con ctelo nuevamente Aparece la visualizaci n normal Es posible que el motor opere unos minutos hasta que la unidad se vuelva a configurar Si el problema no se corrige el c digo de error vuelve a aparecer en 6 minutos Instrucciones de instalaci n PROCEDIMIENTOS DE DESINFECCI N Para completar la instalaci
27. to fill the brine tank See Step 8 WHERE TO INSTALL THE SOFTENER Place the softener as close as possible to a sewer drain or other acceptable drain point or standpipe It is recommended to keep outside faucets on hard water to save soft water and salt Do not install the softener in a place where it could freeze Freeze damage is not covered by the warranty Do not install the softener where it would block access to the water heater or access to the main water shutoff Put the softener in a place where water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for water damage A 120 volt electric outlet is needed to plug in the included transformer The softener has a 10 foot power cable If the outlet is remote up to 100 feet use 18 gauge wire to connect Be sure the electric outlet and transformer are in an inside location to protect from wet weather Be sure the outlet is unswitched to prevent accidental shutoff If installing in an outside location you must take the steps necessary to assure the softener installation plumbing wiring etc are as well protected from the elements sunlight rain wind heat cold contamination vandalism etc as when installed indoors Outdoor installation is not recommended and voids the warranty Keep the softener out of direct sunlight The sun s heat may distort non metallic parts and may damage the electronics Installatio
28. 0025 49 50177 WS60x10014 DESCRIPCI N DE LA PARTE INTERRUPTOR PASADOR EXPANSI N TORNILLO CUBIERTA DE LA V LVULA RESORTE DE ONDA ROTOR Y DISCO TAPA VENTURI SELLO DE ARO T RICO APOYO DE FILTRO FILTRO TAP N DE FLUJO 0 10 GPM JUNTA Y ASPIRADOR FILTRO C NICO TAP N FLUJO DE LLANADO 0 30 GPM TUERCA DE LA F RULA UERPO DE LA BOQUILLA VENTURI ETENEDOR ELLO DE ARO TORICO 1 4 X 3 8 UERPO DE LA VALVULA ESORTE APON SELLO DEL DRENAJE NSAMBLADURA DE LA BOQUILLA VENTURI KIT DEL SELLO 3 4 ADAPTADOR MANGUERA DE DRENAJE PARA DRENAJE ARO TORICO 5 8 X 13 16 TAPON DE FLUJO CONTROL DE ENJUAGUE CLIP LEVA Y ENGRANAJE RODAMIENTO PLATO DEL MOTOR 3 4 TORNILLO 6 20 X 3 8 ENSAMBLADURA DEL MOTOR TORNILLO 6 20 X 7 8 ADAPTADOR ENROSCADO DE NPT VALVULA NORMAL CLIP CABLEADO ENSAMBLADURA DEL SENSOR 3 4 ENSAMBLADURA DE LA TURBINA Y SOPORTE SELLO DE ARO T RICO ENSAMBLADURA DE LA V LVULA DE BYPASS SELLO DE ARO TORICO MANUAL DEL PROPIETARIO KIT DE INSTALACION DANDA m 248 CMR del Commonwealth de Massachusetts 02 PBREBRENPRPBPBPP PE PPP P PA Ra 525 Meerrr PEM ge com 57 Garant a GE para el Sistema de Descalcificaci n de Agua Todos los servicios de garant a son proporcionados por nuestra red de Pegue su recibo aqu La prueba Ga proveedores de servicios autoriz
29. ADD WATER AND SALT TO THE BRINE TANK Lift the salt hole cover Add about 3 gallons of water into the tank Do not add into the brinewell e Fill tank with NUGGET PELLET or coarse SOLAR water softener salt with a purity of 99 5 or higher Do not use rock block granulated and ice cream making salts or salt with iron removing additives except for Diamond Crystal RedeOut brand salt Maximum salt storage capacity is approximately 200 lbs Keep the salt hole cover closed unless servicing the unit or refilling with salt NOTE If the softener is installed in a humid basement or other damp area it is better to fill the tank with less salt more frequently Eighty to 100 lbs of salt will last for several months depending on water hardness family size and water softening system model Installation Instructions 9 CONNECT TO ELECTRICAL POWER To gain access to the transformer power cord assembly remove the salt hole cover from the softener Unclip the tabs on the rear of the top cover and rotate the cover upward to remove DO NOT PULL OR DISCONNECT WIRING The softener works on 24 volt 60Hz electric power The included transformer changes standard 120 volt AC house power to 24 volts Plug the transformer into a 120 volt outlet only Be sure the outlet is always live so it can not be switched off by mistake e Replace the top cover e Replace the salt hole cover PROGRAMMING THE CONTR
30. BEFORE USING A WARNING For your safety the information in this manual must be followed to minimize the risk of electric shock property damage or personal injury SAFETY PRECAUTIONS Ny Via N Check and comply with your state and local codes You must follow these guidelines Use care when handling the water softening system Do not turn upside down drop drag or set on sharp protrusions Water softening systems using sodium chloride salt for recharge add sodium to the water Persons on sodium restricted diets should consider the added sodium as part of their overall intake Potassium chloride can be used as an alternative to sodium chloride in your softener The water softening system works on 24 volt 60 Hz electrical power only Be sure to use only the included transformer Transformer must be plugged into an indoor 120 volt grounded outlet only 9 PROPER INSTALLATION Use clean water softening salts only at least 99 5 pure NUGGET PELLET or coarse SOLAR salts are recommended Do not use rock block granulated or ice cream making salts They contain dirt and sediments or mush and cake and will create maintenance problems Keep the salt hole cover in place on the softener unless servicing the unit or refilling with salt A WARNING bo not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system This water softening system m
31. Destornillador Cinta de tefl n Cuchilla Dos llaves ajustables Se pueden requerir herramientas adicionales si se necesita efectuar modificaciones a la plomer a de la vivienda Los accesorios de entrada y salida incluidos con el descalcificador est n adaptadores macho NPT de 1 2 5 cm Debe mantener un tama o igual o mayor de tubos que los tubos del suministro del agua hacia la entrada y salida del descalcificador Luego use los adaptadores necesarios para conectar el suministro de agua hacia los adaptadores macho NPT de 1 2 5 crm Use la v lvula de bypass incluida para instalar el descalcificador La v lvula de bypass le permite desconectar el suministro de agua hacia el descalcificador para efectuar servicio pero a n mantiene el agua llegando a las tuber as de la casa Los adaptadores macho NPT a que nos referimos anteriormente se conectan a la v lvula de bypass con las tuercas y arandelas incluidas Utilice material de conexi n tuber a apropiado por ejemplo cobre lat n galvanizado o CPVC para conectar los adaptadores pl sticos NTP de 1 a la plomer a de la vivienda Si una manguera adicional es necesaria para el drenaje de la v lvula y el tanque de sal usted la puede solicitar en Accesorios GE llamando al 800 626 2002 no de parte WS07X10004 Si necesita una v lvula r gida de drenaje para cumplir con los c digos de plomer a podr comprar las partes necesarias para conectar un drenaje de tube
32. N EN BUSQUEDA DE FUGAS DE AGUA A PR ECAUCI N Para evitar da os por la presi n de agua o de aire en las partes internas del descalcificador cerci rese de dar los pasos siguientes en el mismo orden en que se presentan Abra completamente 2 grifos de agua descalcificada fr a en grifos cercanos al descalcificador Abra la v lvula de bypass en la posici n bypass empujando el v stago hacia adentro Abra completamente la v lvula de cierre de la tuber a del agua principal de la casa Observe un flujo fijo de ambos grifos abiertos anteriormente PURGUE LAS TUBER AS SAQUE EL AIRE DEL DESCALCIFICADOR Y PRUEBE SU INSTALACION EN BUSQUEDA DE FUGAS DE AGUA CONT e Coloque la v lvula de bypass en la posici n de servicio en la forma EXACTA como le especificamos a continuaci n MANTENGA LOS GRIFOS DE AGUA DESCALCIFICADA ABIERTOS LENTAMENTE tire o deslice el v stago de la v lvula hacia afuera hacia servicio pausando varias veces para permitir que la presurizaci n del descalcificador comience lentamente e Despu s de unos 3 minutos abra un grifo de agua CALIENTE por 1 minuto o hasta que todo el aire haya sido extra do luego ci rrelo NOTA Si parece que el agua est turbia o tiene un sabor salado permita que el sistema funcione por unos minutos m s o hasta que se aclare e Cierre todos los grifos de agua Inspeccione en b squeda de fugas en la tuber a que se acaba de lle
33. N NORMAL ILUSTRACI N DE LA INSTALACI N OPCIONAL TUBER 4 DE UNA DERIVACION DE 3 VALVULAS Agua DE descalcificada TU Agua dura BER a DE hacia los Agua descalcificada grifos Agua dura hacia los Transformador Tomacorriente de 24V de 120 voltios Transformador Adaptadores grifos de 24V Tomacorriente de 120 voltios Adaptadores macho V lvula de salida NPT de 1 2 5 cm 2 c Adaptadores hembra de 1 Tapa del Soe t ricos 2 N 2 5 cm no incluidos 2 orificio RS pS la sal kK ie S mocha NET DS orificio macho NPT de V lvula dura de entrada V lvula hembra de 1 externos de bypass 2 5 cm no incluidos 2 Aros t ricos 2 ENTRADA Clips 2 Sistema de derivaci n de 3 v lvulas Para el servicio de agua descalcificada Abra las v lvulas i de entrada y de salmuera vol Hoge a salida e Cierre la v lvula Fig 2 de bypass V A DE ENLACE Para circunvalar VA AQU i Dep sito de E NOTA Ver la secci n la salmuera Conexiones de la Dep sito gt manguera de drenaje Fig 1 v a DE ENLACE Usela si el flujo de suministro fluye desde la izquierda Incluya una derivaci n sencilla o de 3 v lvulas Agua dura Agua descalcificada De la salida del descalcificad Hacia la entrada del descalcificador Tp Usela si el flujo de suministro fluye el agua dura e Cierre las v lvulas de entrada y de
34. OL PROGRAMMING THE CONTROL CONTROL SETTINGS REQUIRED upon installation and after an extended power outage NOTES WHEN THE TRANSFORMER IS PLUGGED INTO THE ELECTRICAL OUTLET 12 00 PM flashing and PRESENT TIME is displayed Program the control as instructed below If 5R is flashing use the UP A button to set the correct model code as follows F30 for GXSF30H If you pass by the correct code number use the DOWN Y button Then press the MODE button to accept the correct model A beep sounds while pressing buttons for control programming One beep signals a change in the control display Repeated beeps mean the control will not accept a change from the button you have pressed and you should select another button To program the control you will use the UP A DOWN Y and MODE buttons e Use the MODE button to select the desired control function SET PRESENT TIME OF DAY 1 Press the MODE button until PRESENT TIME appears in the iS display PRESENT TIME Press UP A or DOWN y button to set The UP button 4 E di advances the time the DOWN PRESENT TIME button moves the time in reverse If the present time is between noon and midnight be sure PM shows in the display If the present time is between midnight and noon be sure AM shows in the display NOTE Each press of an UP A or DOWN y button changes the time by one minute Holding the button changes the time at a rapid ra
35. P or DOWN button until the correct number shows 3 Press the MODE button to return to the present time display If the code was changed make ALL the timer settings NOTE If the control is left in a diagnostic display or a flashing display when setting times or hardness present time automatically returns if a button is not pressed within four minutes 17 About the water softener system 18 Service Manually Advance Recharge Check NOTE The control display must show a steady time not flashing 1 Press the RECHARGE button and hold in for three seconds RECHARGE NOW begins to flash as the water softening system enters the fill cycle of recharge Remove the brinewell cover and using a flashlight observe fill water entering the brine tank If water does not enter the tank look for an obstructed nozzle venturi fill flow plug or brine tubing See Care and Cleaning of the Water Softener System section 2 After observing fill press the RECHARGE 9 button to move the water softening system into brining A slow flow of water to the drain will begin Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level over an extended period of time NOTE Be sure a salt bridge is not preventing water from contacting salt See Care and cleaning of the water softening system section If the water softening system does not draw brine check
36. RBINE amp SUPPORT ASM SEAL O RING BYPASS VALVE ASM SEAL O RING OWNER S MANUAL INSTALLATION KIT NZNVBBOAADV 02 Rbeo pRPpPRERPNNERENRRRRRRRARRRRAN btt y pp plumber and do not permit the use of the saddle valve For installation use plumbing code 248 CMR of the Commonwealth of Massachusetts GE Water Softening System Warranty For Customers in the United States Network To schedule service call 800 952 5039 U S or 866 777 7627 Canada Please have serial number and model number available when calling for service Ea All warranty service provided by our SmartWater Authorized Servicer For The Period Of One Year From the date of the original purchase Staple your receipt here Proof of the original purchase date is needed to obtain service under the warranty We Will Replace Any part of the Water Softening System which fails due to a defect in materials or workmanship During this limited one year warranty GE will also provide free of charge all labor and related service to replace the defective part Three Years From the date of the original purchase The electronic monitor if it fails due to a defect in materials or workmanship During this three year limited warranty you will be responsible for any labor or related service costs Ten Years From the date of the original purchase A replacement brine tank or cabinet if either fail
37. a es el agente de limpieza necesario para remover los minerales duros de la capa de resina Los minerales duros y la salmuera son descargados hacia el desague La boquilla y el Venturi crean una succi n para mover la salmuera manteniendo un ritmo muy bajo para obtener la resina de limpieza con la menor cantidad de sal Enjuague de Salmuera Despu s de que se use una cantidad de salmuera medida con anterioridad la v lvula de salmuera se cierra El agua contin a fluyendo en la misma trayectoria que durante el proceso de salado excepto por el flujo de salmuera discontinuado Los minerales duros y la salmuera fluyen del tanque de resina hacia el desague Sin embargo usted debe evitar usar agua CALIENTE porque el calentador de agua se llenar con agua dura Lavado Regresivo Durante el lavado regresivo el agua viaja hacia arriba a trav s del tanque de resina a un flujo de ritmo r pido purgando el hierro acumulado la suciedad y los sedimentos desde la capa de resina hacia el desague Enjuague R pido El lavado regresivo es seguido por un flujo de agua r pido hacia abajo a trav s del tanque de resina El flujo r pido purga la salmuera del fondo del tanque y rellena el tanque de resina A continuaci n del enjuague r pido el sistema de descalcificaci n de agua regresa al servicio de agua descalcificada 41 Sobre el sistema de descalcificaci n de agua 42 C mo romper un puente de sal A veces un
38. a capa dura de sal o puente de sal se forma en el rea de almacenamiento de la sal Esto generalmente se debe a la humedad alta o al uso de alg n tipo de sal equivocada Cuando la sal forma puente un espacio vac o se forma entre el agua y la sal Entonces la sal no se disuelve en el agua para hacer la salmuera Si el tanque de la sal est lleno de sal es dif cil saber si existe o no un puente de sal La sal est floja en la parte superior pero el puente est por debajo A continuaci n la forma m s efectiva de inspeccionar si existe la formaci n de un puente de sal La sal debe estar floja desde arriba hasta el fondo del tanque Tome un palo de escoba o algo parecido y con cuidado emp jelo hacia el interior del dep sito de sal introduci ndolo y sac ndolo Si el instrumento golpea un objeto duro cerci rese de que lo que golpea no es el fondo o las paredes laterales del tanque es posible que exista un puente de sal Con cuidado rompa el puente con el instrumento No golpee las paredes del tanque Si el tipo de sal equivocada es usado para hacer el puente s quela Entonces llene el tanque con la sal apropiada En reas h medos es mejor llenar el dep sito con menos sal y hacerlo m s a menudo 12 2 54 cm 5 08 cm de l piz Instrumento Empuje el instrumento hacia el interior del dep sito de sal para romper el puente Nivel de agua ge com C mo limpiar la ensambladura de la b
39. ados SmartWater Para programar un de la fecha de la compra original servicio llame al 800 GE CARES 800 952 5039 Cuando llame para es necesaria para recibir el solicitar servicio por favor tenga a mano el n mero de serie y el servicio bajo la garant a n mero de modelo Por el per odo de Reemplazamos Uno a o Cualquier parte del Sistema de descalcificaci n de agua que falle debido a defectos de materiales A partir de la fecha o en la fabricaci n Durante esta garant a limitada de un a o GE tambi n le proporcionar de la compra original de manera gratuita toda la mano de obra y servicios relacionado para reemplazar partes defectuosas Tres a os El monitor electr nico si el mismo falla debido a defectos de materiales o en la fabricaci n Durante A partir de la fecha este per odo de tres a os de garant a limitada usted ser responsable por cualquier mano de obra o de la compra original costos de servicio relacionado Diez a os Un gabinete o tanque de salmuera de reposici n si cualquiera de los dos falla debido a defectos de A partir de la fecha materiales o en la fabricaci n Durante este per odo de diez a os de garant a limitada usted ser de la compra original responsable por cualquier mano de obra o costos de servicio relacionado Lo que no est cubierto E Viajes de servicio a su casa para ense arle c mo usar E Reemplazo de los fusibles de la casa o reajustes de los el producto circuit
40. alt is loose on top but the bridge is under it The following is the best way to check for a salt bridge Salt should be loose all the way to the bottom of the tank Take a broom handle or like tool and carefully push it down into the salt working it up and down If the tool strikes a hard object be sure it s not the bottom or sides of the tank it s most likely a salt bridge Carefully break the bridge with the tool Do not pound on the walls of the tank If the wrong kind of salt made the bridge take it out Then fill the tank with nugget or pellet salt only In humid areas it is best to fill with less salt more often to prevent a salt bridge from forming Push tool into salt bridge to break V L Pencil mark Water level Cleaning the Nozzle and Venturi Assembly A clean nozzle and venturi is needed for the water softening system to work properly This small unit makes the suction to move brine from the salt storage area to the resin tank during recharge If it becomes plugged with sand dirt etc the water softening system will not work and you will get hard water To get to the nozzle and venturi remove the water softening system top cover Be sure the water softening system is in service cycle no water pressure at nozzle and venturi Then while holding the nozzle and venturi housing with one hand remove the cap Lift out the screen support and screen then the nozzle and venturi Wash and rinse the pa
41. ater DO NOT RUN HOT WATER THROUGH THE SOFTENER Temperature of water passing through the softener must be less than 120 F IMPORTANT INSTALLATION RECOMMENDATIONS CONT Use care when handling the softener Do not turn upside down drop drag or set on sharp protrusions Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nighttime pressure may exceed the maximum Use a pressure reducing valve if necessary Adding a pressure reducing valve may reduce the flow The softener works on 24 volt 60 Hz electrical power only Be sure to use the included transformer Be sure the electric outlet and transformer are in an inside location to protect from moisture See Where to Install the Softener section for more details AWARN ING do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system The water should be tested periodically to verify that the system is performing satisfactorily Small parts remaining after the installation could be a choke hazard Discard safely Installation Instructions UNPACKING AND INSPECTION Be sure to check the entire softener for any shipping damage or parts loss Also note damage to the shipping cartons Contact the transportation company for all damage and loss claims The manufacturer is not responsible for damages in transit Small parts needed to install the softener ar
42. ater iron out of water or over the maximum of clear water iron an iron filter or other equipment is needed GE recommends using only Diamond Crystal RedeOut brand salts with Iron Fighter additive to help keep the resin bed clean of clear iron If your water supply has clear water iron periodic resin bed cleaning is needed GE recommends using Super Iron Out brand resin bed cleaner to thoroughly clean your resin bed if your iron content is high Clean the bed at least every six months or more often if iron appears in the soft water between cleanings IMPORTANT It is important to mix the resin bed cleaner with water following the manufacturer s instructions pour it into the brinewell tube see page 5 and recharge the softener immediately Do not pour the resin bed cleaner in with the salt as it will not be as effective in cleaning the resin and can cause damage to the softener if it is left in the brine tank for an extended period due to the corrosive gases that are formed 19 Before you call for service Troubleshooting Tips Save time and money Review the chart on the following pages first and you may not need to call for service NO SOFT WATER Most Common Problems Check the following before calling for service e Not enough salt should be at least 1 3 full e Bypass valve in Bypass position knob should be in the OUT service position e Hardness setting too low Check hardness s
43. cleaning agent needed to remove hard minerals from the resin beads The hard minerals and brine are discharged to the drain The nozzle and venturi create a suction to move the brine maintaining a very slow rate to get the best resin cleaning with the least salt Brine Rinse After a pre measured amount of brine is used the brine valve closes Water continues to flow in the same path as during brining except for the discontinued brine flow Hard minerals and brine flush from the resin tank to the drain However you should avoid using HOT water because the water heater will fill with the hard water Backwash During backwash water travels up through the resin tank at a fast flow rate flushing accumulated iron dirt and sediments from the resin bed and to the drain Fast Rinse Backwash is followed by a fast flow of water down through the resin tank The fast flow flushes brine from the bottom of the tank and packs the resin bed After fast rinse the water softening system returns to soft water service 13 About the water softener system 14 Breaking a Salt Bridge Sometimes a hard crust or salt bridge forms in the salt storage area It is usually caused by high humidity or the wrong kind of salt When the salt bridges an empty space forms between the water and salt Then salt will not dissolve in the water to make brine If the brine tank is full of salt it is hard to tell if you have a salt bridge S
44. ctory default should show in the display This is a good time for recharge to start takes about 2 hours in most households because water is not in use HARD WATER is bypassed to house faucets during recharge If no change is needed go to step 3 To change the recharge starting time follow step 2 2 Press UP A or DOWN Y button to set the desired recharge start time Be sure to observe the AM or PM as you did when setting the time of day NOTE Each press of a button changes the time by 1 hour Holding the buttons in changes the time at a rapid rate 3 Press the MODE button to accept OPTIONAL CONTROL SETTINGS The controller display has several options and features SYSTEM ELECTRONIC DIAGNOSTICS This display contains system diagnostics information to assist in or F troubleshooting problems with the Water Softener See page 17 To access the System Diagnostics press and hold the MODE button for 3 seconds To return to the normal display press the MODE button 2 times SALT EFFICIENCY When the SALT EFFICIENCY feature is ON the unit will operate at a salt efficiency of at least 4000 grains of hardness removed per pound of salt This mode of operation is the most efficient setting for salt usage because the system will tend to recharge more often with less salt usage Turning the feature OFF will tend to lengthen the time between recharge cucles which will provide the most
45. ctronic Diagnostics The control computer has a self diagnostic function for the electrical system except input power and water meter The computer monitors the electronic components and circuits for correct operation If a malfunction occurs an error code appears in the control display The chart on Error Codes shows the error codes that could appear and possible reasons for each code See Manually Initiated Electronics Diagnostics to further isolate the defect 15 About the water softener system Service Electronic Demand Time Features and Service ERROR CODE DISPLAYED ERR 01 ERR 02 ERR 03 ERR 04 ERR 05 POSSIBLE DEFECT Motor e Position e Motor e Position Control inoperative switch inoperative switch or or wiring wiring harness harness e Wiring eControl Control Control harness or connection to switch Position switch e Control To remove an error code 1 Unplug transformer 2 Correct defect 3 Plug transformer in 4 Wait for at least 6 minutes The error code will return if the reason for the error code was not corrected Service Timer Softener Service Checkout Procedure If you are not getting soft water and an error 2 Is there sufficient salt in the storage tank code is not displayed use the procedures below to find the problem First make the following visual checks 3 Is the softener bypass valve directing water for soft water service 4 Is the valve drain hose open to the d
46. d outlet valves e Close the Fig 2 bypass valve _ CROSSOVER For bypass hard Use if water supply flows water from the left Include single Close the inlet or 3 valve bypass and outlet valves e Open the bypass valve To softener inlet Installation Instructions BEFORE YOU BEGIN Turn off the gas or electric supply to the water heater in the possibility that the water heater may be drained while draining pipes Turn off the water supply to pipes to be cut and drain the house water pipes Open both hot and cold faucets at the lowest location possible NOTE For easier installation remove the top cover Release 2 clips at rear of cover Rotate cover forward and lift up 1 INSTALL BYPASS VALVE e Remove plastic shipping plug and wire from valve outlet Turbine Valve outlet Turbine shaft and support NOTE Be sure the turbine and support are firmly in place in the valve outlet Blow into the valve port and observe the turbine for free rotation e Push the bypass valve lubricate o ring seals with silicone grease into both ports of the valve as shown NPT adapter Drain fitting Tnlet O rings O ring seal goes into the outer groove only The clip snaps into the inner groove see below e Snap the 2 large plastic clips in place from the top down as shown SIDE Clip l ybes valve Valve body push all the way in inlet or outlet e Push the NPT adapters l
47. das por este control desde que el n mero de sost ngalo oprimido por tres segundos hasta que el c digo de ritmo de Servicio aparezca en la pantalla c digo SR fue entrado ORE Para que el sistema de descalcificaci n de agua opere correctamente el c digo del modelo debe ser F30 por modelo GXSF30H Para reajustar el c digo presione el bot n de UP hacia arriba DOWN hacia abajo hasta que los n meros correctos sean mostrados 3 Presione MODE modo para regresar a la pantalla de tiempo presente Si el c digo fue cambiado haga TODOS los ajustes del sincronizador NOTA Si el control es dejado en una visualizaci n de diagn stico o en una pantalla intermitente cuando los ajustes de tiempo o la dureza el tiempo presente regresa autom ticamente si un bot n no es oprimido dentro de cuatro minutos ge com Servicio Inspecci n manual del avance de la recarga NOTA La pantalla de control debe mostrar la hora de manera estable no intermitente 1 Presione el bot n RECHARGE recarga 0 y sost ngalo presionado por tres segundos La palabra RECHARGE NOW recargue ahora comienza a parpadear a medida que el sistema de descalcificaci n de agua inicia el ciclo de recarga Retire la cubierta del dep sito de la salmuera y con una linterna observe el agua de llenado entrando hacia el tanque de salmuera Si no hay agua entrando al tanque busque cualquier obstrucci n en una boquilla el Ventur
48. de GE p ngase en contacto con nosotros en nuestra p gina Web indicando todos los detalles as como su n mero de tel fono o escr banos a General Manager Customer Relations GE Appliances Appliance Park Louisville KY 40225 Registre su electrodom stico ge com Registre su nuevo electrodom stico en linea cuando usted prefiera El registrar su producto a tiempo le proporcionar si surgiera la necesidad una mejor comunicaci n y un servicio m s r pido bajo los t rminos de su garant a Tambi n puede enviar su tarjeta de registro pre impresa que se incluye en el material de embalaje 59 Consumer Support GE Appliances Website ge com Have a question or need assistance with your appliance Try the GE Appliances Website 24 hours a day any day of the year For greater convenience and faster service you can now download Owner s Manuals or order parts online Schedule Service ge com Expert GE repair service is only one step away from your door Schedule your service at your convenience by calling 800 GE CARES 800 432 2737 during normal business hours Real Life Design Studio ge com GE supports the Universal Design concept products services and environments that can be used by people of all ages sizes and capabilities We recognize the need to design for a wide range of physical and mental abilities and impairments For details of GE s Universal Design applications including kitchen design ideas for peop
49. de habilidades y dificultades f sicas y mentales Para m s detalles cobre las aplicaciones de GE Dise o Universal incluyendo ideas de dise o para la cocina para personas con discapacidades mire nuestra p gina Web hoy mismo Para personas con dificultades auditivas favor de llamar al 800 TDD GEAC 800 833 4322 Garant as ampliadas ge com Compre una garant a ampliada y obtenga detalles sobre descuentos especiales disponibles mientras su garant a X est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estar a n ah cuando su garant a termine Piezas y accesorios ge com Aquellos individuos con la calificaci n necesaria para reparar sus propios electrodom sticos pueden pedir que se les manden las piezas o accesorios directamente a sus hogares aceptamos las tarjetas VISA MasterCard y Discover Haga su pedido en l nea hoy 24 horas cada d a o llamar por tel fono al 800 626 2002 durante horas normales de oficina Las instrucciones descritas en este manual cubren los procedimientos a seguir por cualquier usuario Cualquier otra reparaci n deber a por regla general referirse a personal calificado autorizado Debe ejercerse precauci n ya que las reparaciones incorrectas pueden causar condiciones de funcionamiento inseguras P ngase en contacto con nosotros ge com LA Si no est satisfecho con el servicio que recibe
50. de la v lvula Arandela Manguera de drenaje Al drenaje de sobreflujo aceptable Instrucciones de instalaci n 6 INSTALE LA ABRAZADERA DE TIERRA APELIGRO No adherir apropiadamente la abrazadera de tierra podr a resultar en una descarga el ctrica Si las tuber as son de metal para mantener continuidad de tierra el ctrica en la tuber a de agua fr a instale la abrazadera de tierra incluida como se muestra 9 Limpie la tuber a con papel de esmerilar en el rea donde la abrazadera ser instalada e Instale las abrazaderas de conexi n a tierra como se muestra cercior ndose que las abrazaderas ajustan libremente alrededor de la tuber a e Cerci rese de que la arandela de cierre est en su lugar e Apriete con sus manos el tornillo luego una vuelta completa adicional con el destornillador NOTA Cuando reemplace un descalcificador existente tambi n reemplace las abrazaderas de conexi n a tierra Si se dispone a remover el descalcificador completamente coloque tuber as en las l neas de agua del mismo tipo que las tuber as usadas originalmente para asegurar la integridad de las tuber as y continuidad en la conexi n a tierra a lo largo de la vida de la casa Hacia la entrada de la v lvula gc Abrazadera gt Proveniente de la salida de la v lvula PURGUE LAS TUBER AS SAQUE EL AIRE DEL DESCALCIFICADOR Y PRUEBE SU INSTALACIO
51. de la v lvula de bypass se encuentre la posici n de bypass en la posici n correcta con el bot n en la posici n OUT afueral Observe las instrucciones en la etiqueta en el extremo de la palanca La v lvula de la manguera de drenaje est Cualquier restricci n en esta manguera de drenaje puede prevenir atascada obstruida elevada a una posici n la operaci n apropiada de la boquilla y el Venturi y reducir o evitar demasiado alta u obstruida de alguna forma la toma de la salmuera durante la recarga La boquilla y el Venturi est n sucios Consulte las instrucciones para Limpiar la boquilla y el Venturi ensamblados incorrectamente o da ados Con la presi n del agua desconectada del sistema de descalcificaci n de agua desarme la ensambladura de la boquilla Inspecci nela l mpiela y reemplace cualquier parte seg n sea necesario Cualquier part cula extra a ralladura muesca etc en los pasajes puede impedir la operaci n Cerci rese de que los agujeros peque os en la junta est n centrados directamente sobre los peque os agujeros en el alojamiento 49 Antes de llamar para solicitar servicio Consejos para la identificaci n y soluci n de aver as Problema A veces el agua est dura El agua se siente resbalosa despu s de la instalaci n del sistema de descalcificaci n de agua El sistema de descalcificaci n de agua no est usando ninguna sal El agua tiene un color azul despu s de que el si
52. e el control no acepta un cambio del bot n que usted ha oprimido y que usted debe oprimir otro bot n e Para programar el control usted usar los botones UP A DOWN y y MODE modo e Utilice el bot n MODE modo para seleccionar la funci n de control deseada 38 AJUSTE LA HORA DEL DIA 1 Presione el bot n MODE modo hasta que PRESENT TIME hora actual se visualice 2 Oprima el bot n UP A o DOWN y para ajustar El bot n UP se mueve hacia adelante el bot n DOWN se mueve hacia atr s Si la hora actual es entre el medio d a y la media noche cerci rese de que PM se visualice Si la hora actual es entre la media noche y el medio d a cerci rese de que se visualice NOTA Cada vez que usted oprime los botones UP DOWN W tiempo cambiar en un minuto Sostener uno de los botones oprimido har que la hora cambie a un ritmo r pido 3 Cuando se muestra la hora actual oprima MODE modo para aceptar 1 PRESENT TIME Nm LAT eL PRESENT TIME AJUSTE EL NIVEL DE DUREZA DEL AGUA 1 Oprima el bot n MODE modo hasta que HARDNESS dureza se visualice 2 Oprima los botones UP DOWN Y para ajustar la dureza del agua en la pantalla DOWN disminuye el nivel de dureza UP aumenta el nivel de dureza NOTA Cada vez que usted oprime un bot n la visualizaci n cambia un n mero entre 1 y 25 Por encima de 25 la visualizaci n cambia los n meros
53. e packaged either in a bag or on a cardboard sheet To avoid loss of the small parts keep them packaged until you are ready to use them Be sure not to discard components hidden in packaging TOOLS AND MATERIALS REQUIRED FOR INSTALLATION Pliers Screwdriver Teflon tape Razor knife Two adjustable wrenches Additional tools may be required if modification to home plumbing is necessary In and out fittings included with the softener are 1 NPT male adapters You should maintain the same or larger pipe size as the water supply pipe up to the softener inlet and outlet Then use the necessary adapters to connect the water supply to the 1 NPT male adapters Use the included bypass valve to install the softener The bypass valve allows you to turn off water to the softener for servicing but still have water in the house pipes The NPT male adapters referred to above connect to the bypass valve with the included plastic clips Use appropriate fitting pipe material i e copper brass galvanized or CPVC to connect the 1 NTP plastic adapters to the house plumbing If additional drain hose is needed for valve and salt tank drains it can be ordered from GE Parts at 800 626 2002 part number WS07X10004 If a rigid valve drain is needed to comply with plumbing codes you can buy the parts needed to connect a 1 2 copper tubing or plastic pipe drain See Step 4 Clean nugget or pellet water softener salt is needed
54. eater until the water runs cold AWARN ING ir you do drain the water heater use extreme care as the hot water could cause burns Turn the water heater off prior to draining GXSF30H Rated Capacity 11 800 grains with 2 3 Ibs of salt 25 300 grains with 7 4 lbs of salt 30 200 grains with 12 5 lbs of salt 5 120 grains lb O 2 3 lbs of salt Rated Efficiency Amount of High Capacity Resin Ibs cu ft Resin Tank Nominal Size in dia x height Service Flow Rate gpm Water Supply Maximum Hardness gpg Water Supply Maximum Clear Water Iron ppm Water Pressure Limits min max psi Pressure Drop at Rated Service Flow psig Water Temperature Limits min max F Maximum Flow Rate to Drain gpm N wlNn 40 6 0 78 8 x 40 PS This system conforms to NSF ANSI 44 for the specific capacity claims as verified and substantiated by test data Testing was performed using pellet grade sodium chloride as the regenerant salt Efficiency rating is valid only at the lowest stated salt dosage This softener was efficiency rated according to NSF ANSI 44 Extent of iron removal may vary with conditions The capacity to reduce clear water iron is substantiated by WQA test data State of Wisconsin requires additional treatment if water supply contains greater than 5 ppm clear water iron Use of Diamond Crystal RedeOut or Super Iron Out will improve iron removal Refer to Cleaning Iron Out of t
55. efecto sif n del agua de alcantarillado hacia el descalcificador si ocurriese un ciclo de lavado regresivo Instrucciones de instalaci n CONECTE Y HAGA FUNCIONAR LA MANGUERA DE DRENAJE DE LA VALVULA CONT e Elevar la manguera de drenaje podr a causar una presi n negativa que podr a reducir la toma del contenido de sal durante las regeneraciones Si fuera necesario levantar la manguera de drenaje hasta un nivel superior al descalcificador para llegar hasta el punto de drenaje mida primero la presi n de entrada de agua hacia el descalcificador Para las presiones de entrada entre 20 y 50 psi no eleve m s de 8 pies 2 67 m por encima del piso Para la presi n de entrada por encima de 50 psi la manguera de drenaje podr a levantarse a una altura m xima de 14 pies Luz indicadora azul Manguera de drenaje de la i v lvula tolerancia de 1 Abrazadera 3 8 cm SUMIDERO drenaje en la v lvula Ate o amarre la manguera Espacio de tolerancia en su lugar TUBO REGULADOR Espacio de y tolerancia de 14 3 8 cm DRENAJE DE PISO C MO CONECTAR UN TUBO DE DRENAJE DE VALVULA RIGIDA Para adaptar un tubo de drenaje de cobre descalcificador use una sierra de arco para cortar el extremo de p a del accesorio de drenaje tal y como se muestra Rote el accesorio de drenaje de forma tal que la hoja de corte evite el alojamiento de la v lvula para prevenir da os a la v lvula C
56. efficient usage of water but may use more salt The degree of difference between these two cucles is highly dependent on the water usage and hardness at a particular installation NOTE California Regulations require this feature to be ON for installations in California To access the Salt Efficiency press and hold the MODE button for 3 seconds The System Diagnostics display will appear Press the MODE button again and the Salt Efficiency display will appear To change the setting press the UP or DOWN Y buttons to toggle the feature ON or OFF Press the MODE button to accept ERROR SIGNALS If there is an error code detected the display will flash Err to signal that the softener requires service See page 16 for information to assist in troubleshooting error codes Once the problem is corrected disconnect the transformer from the wall outlet momentarily and plug it back in The normal display will appear The motor may run for several minutes as the unit resets If the problem is not corrected the error code will reappear in 6 minutes Installation Instructions SANITIZING PROCEDURES To complete the installation do the following sanitizing procedures Care is taken at the factory to keep your water softener clean and sanitary Materials used to make the softener will not infect or contaminate your water supply and will not cause bacteria to form or grow However during shipping storage instal
57. el ctrica hacia el control interruptor transformador cable el ctrico y todas las conexiones LA PANTALLA DE CONTROL EST EN BLANCO LA PANTALLA DE CONTROL MUESTRA LA Realice diagn stico manual HORA CORRECTA Y EL DIA Y NO ESTA INTERMITENTE SIN SUMINISTRO REPARE SEGUN SEA Lleve a cabo los NECESARIO diagn sticos manuales para verificar que todo funciona correctamente CONTROL DEFECTUOSO 45 Sobre el sistema de descalcificaci n de agua Servicio Diagn stico electr nico iniciado manualmente 1 Para entrar diagn sticos oprima y Interruptores sostenga oprimido el bot n MODE modo de turbinas hasta que se muestre 000 en la pantalla to p A Los primeros tres d gitos indican la Medidor Interruptor operaci n del medidor de agua de la ae B forma siguiente 000 intermitente agua descalcificada no en uso no hay flujo a trav s del medidor ABRA UN GRIFO DE AGUA DESCALCIFICADA QUE ESTE CERCA 000 hasta 199 continuo repite la visualizaci n para cada gal n de agua que pase a trav s del medidor Interruptor de posici n Alojamiento del sensor Turbina Soporte de la turbina y eje Salida de la v lvula Si usted no recibe una indicaci n en la pantalla con el grifo abierto tire el sensor desde el puerto de salida de la v lvula Pase un peque o im n hacia atr s y hacia
58. ente cuando se trata de agua de pozo Para inspeccionar h gale una prueba al agua en un laboratorio de an lisis o llame a su compa a local de suministro de agua Ajuste el valor de la HARDNESS dureza seg n sea necesario Esto es normal La dureza le da la sensaci n abrasiva al agua a la que usted est acostumbrado Esta sensaci n de que el agua resbalosa es porque ahora ha sido descalificada No usa tanta sal para regenerarse es muy eficiente Consulte la secci n Sobre el sistema de descalcificaci n de agua en la p gina 42 Consulte la secci n Sobre el sistema de descalcificaci n de agua en la p gina 43 Inmediatamente solicite que se le haga una prueba al agua Consulte la secci n Servicio Diagn stico electr nico iniciado manualmente para procedimientos de soluci n de aver as en la p gina 46 Llame y solicite servicio Consulte la secci n Servicio Diagn stico electr nico iniciado manualmente para procedimientos de soluci n de aver as en la p gina 46 Llame y solicite servicio Inspeccione el interruptor de circuito o los fusibles Llame y solicite servicio A esto se le llama grabado de aguafuerte y es permanente Para evitar que esto suceda use menos detergente si usted tiene agua descalcificada Lave la cristaler a en el ciclo m s corto que los pueda limpiar ge com Problema Nivel alto excesivo de agua en el tanque de la salmuera El agua sabe a sal o tiene as
59. ente y soldadura sin plomo para todas las conexiones de condensaci n soldadas seg n los c digos estatales y federales aplicables El sistema de descalcificaci n de agua requiere un flujo de agua m nimo de tres galones por minuto en la entrada La presi n de entrada m xima permitida es de its of LEA Y SIGA ESTA INFORMACI N DE SEGURIDAD CUIDADOSAMENTE GUARDE ESTAS INSTRUCCIONES 30 Instrucciones Sistema Suavizante de Agua de instalaci n Modelo GXSF3OH A ADVERTENCIA Lea este manual en su totalidad No seguir todas las pautas y normas podr a causar lesiones personales o da os a la propiedad e Consulte con la autoridad de obras p blicas estatal local para los c digos de plomer a Deber seguir estas pautas para instalar el sistema de filtraci n de agua NOTA No cumplir con estas instrucciones de instalaci n invalidar la garant a del producto y el instalador ser responsable por cualquier servicio reparaci n o da os causados ANTES DE EMPEZAR LA INSTALACI N RECOMENDACIONES IMPORTANTES Lea estas instrucciones completa y PARA LA INSTALACION CONT cuidadosamente e Tenga cuidado cuando manipule el 5 Guarde estas instrucciones para uso del inspector local IM PO RTANTE Observe todos los c digos y ordenanzas vigentes Nota al instalador Aseg rese de dejar estas instrucciones al consumidor Nota al consumidor Conserve estas instrucciones para cons
60. er is not available you may be responsible for a trip charge or you may be required to bring the product to an Authorized GE Service location for service In Alaska the warranty excludes the cost of shipping or service calls to your home Some states do not allow the exclusion or limitation of incidental or consequential damages This warranty gives you specific legal rights and you may also have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General Warrantor General Electric Company Louisville KY 40225 27 GE Water Softening System Warranty For Customers in Canada All warranty service provided by our Factory Service Centers or an authorized technician For service call toll free 1 866 777 7627 Please have serial number and model number available when calling for service For The Period Of We Will Replace One Year Any part of the Water Softening System which fails due to a defect in materials or workmanship From the date of the During this limited one year warranty GE will also provide free of charge all labor and related original purchase service to replace the defective part Three Years The electronic monitor if it fails due to a defect in materials or workmanship During this From the date of the three year limited warranty you will be responsible for any labor or related service costs original purchase
61. etting and adjust Verify hardness of supply water from local water company water test or call the GE Answer Center e Salt Bridge salt solidifies above water level so that brine water is not in contact with Problem No soft water 20 Possible Causes Faucet or fixture where sample was taken not plumbed to soft water NOTE Be sure sample is from a faucet that does not mix soft and hard water For example a single lever kitchen faucet if the cold side is plumbed to hard water No salt in the brine tank or salt bridged Transformer unplugged at wall outlet or power cable to softener not connected Fuse blown or circuit breaker popped on circuit to electrical outlet Electrical outlet on a circuit that can continuously be switched off Manual bypass valve in bypass position Valve drain hose pinched plugged elevated too high or otherwise restricted Nozzle and venturi dirty incorrectly assembled or damaged salt See the Breaking a Salt Bridge section What To Do To conserve salt the installer may have isolated some fixtures outside faucets toilets etc from soft water From the outlet of the water softening system trace the water flow path in house plumbing If soft water is not directed to a faucet or fixture where wanted consult a plumber Check for a salt bridge or if the tank is empty refill with recommended salt Press for 3 seconds the RECHARGE button to start an immediate rechar
62. ftener System section page 14 See the About the Water Softener System section page 14 Have the water tested at once See the Service Manually Initiated Electronics Diagnostics section for troubleshooting procedures page 17 e Call for service See the Service Manually Initiated Electronics Diagnostics section for troubleshooting procedures page 17 e Call for service Check the circuit breaker or fuses e Call for service e This is called etching and is permanent To prevent this from happening use less detergent if you have soft water Wash glassware in the shortest cycle that will get them clean Any restriction in this drain hose may prevent proper operation of the nozzle and venturi and reduce or prevent brine draw during recharge See the Cleaning the Nozzle and Venturi Assembly section page 14 With water pressure to the water softening system off take the nozzle assembly apart Inspect clean and replace as needed Any foreign particle s scratches nicks etc in the passages can prevent operation Be sure holes in the gasket are centered over holes in the housing 21 Before you call for service Troubleshooting Tips Problem Salty tasting or brown yellow colored water after installation Brown yellow colored water Resin beads showing up in drinking water and sink Sounds you might hear Water has air bubbles and is cloudy Error Code on control 22
63. ge and restore soft water supply Check for a loss of electrical power to the water softening system due to any of these conditions and correct as needed With the power supply restored observe the faceplate time display and read Programming the Control section NOTE The electrical outlet for the softener should be live so it cannot be accidentally switched off Be sure the bypass valve stem is positioned properly with the knob in the OUT position Observe instructions on the decal at the end of the stem Any restriction in this drain hose may prevent proper operation of the nozzle and venturi and reduce or prevent brine draw during recharge Refer to Cleaning the Nozzle and Venturi Assembly instructions With water pressure to the water softening system off take the nozzle assembly apart Inspect clean and replace as needed Any foreign particle s scratches nicks etc in the passages can prevent operation Be sure holes in the gasket are centered over holes in the housing Problem Water hard sometimes Water feels slippery after installation of water softening system Water softening system not using any salt Water is blue color after water softening system was installed Water softening system not regenerating Cloudiness on glassware automatic dishwashers Excessive high level of water in brine tank Possible Causes Using hot water while the water softening system is regenerating Contr
64. ge com Safety Information 2 Wa te r Softe n g Installation Instructions 3 12 Step by step instructions 6 12 System g E Operating Instructions dd Breaking a salt bridge 14 ooo aj Cleaning the nozzle and venturi 5 14 Model GXSF30H FOQLUTES ir tias 15 3 SOI ind 13 16 18 AAA UY Water softener system 16 18 Sistema Suaviza nte Care and Cleaning 19 de A ua Troubleshooting Tips 20 22 g Manual del Propietario e Consumer Support Instrucciones de Instalaci n Consumer Support Back Cover Parts list catalog 23 26 Modelo GXSF30H Warranty U S 27 La secci n en espa ol empieza en la p gina 29 Warranty Canada 28 System tested and certified by NSF International against NSF ANSI Standard 44 for the chemical reduction claims specified on the performance data sheet Sistema probado y certificado por NSF International contra norma 44 de NSF ANSI para las afirmaciones de reducci n de los productos qu micos especificadas en la hoja de datos de funcionamiento Write the model and serial numbers here Model Serial To find these numbers lift the cover and look on the rim below the control panel Water Softenin 7283918 215C1173P021 49 50177 06 06 JR IMPORTANT SAFETY INFORMATION READ ALL INSTRUCTIONS
65. he Water Softening System section Canada working pressure limits 1 4 7 0 kg cm About the water softener system Service When the water softening system is providing soft water it is called Service During service hard water flows from the house main water pipe into the water softening system Inside the water softening system resin tank is a bed made up of thousands of tiny plastic resin beads As hard water passes through the bed each bead attracts and holds the hard minerals This is called ion exchanging It is much like a magnet attracting and holding metals Water without hard minerals soft water flows from the water softening system and to the house pipes ge com After a period of time the resin beads become coated with hard minerals and they have to be cleaned This cleaning is called recharge Recharge is started at 2 00 AM factory setting by the water softening system control and consists of five stages or cycles These are FILL BRINING BRINE RINSE BACKWASH and FAST RINSE Automatic Hard Water Bypass During Recharge For emergency needs hard water is available to the home during the recharge cycles Fill Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine water flows into the salt storage area during the fill stage Brining During brining brine travels from the salt storage area into the resin tank Brine is the
66. i el tap n de flujo de llenado o la tuber a de la salmuera Consulte la secci n Cuidado y limpieza del sistema de descalcificaci n de agua 2 Despu s de observar el llenado presione el bot n RECHARGE recarga para llevar al sistema de descalcificaci n de agua al proceso de salado Un flujo lento de agua hacia el drenaje debe comenzar Verifique la extracci n de la salmuera del tanque alumbrando con una linterna hacia el dep sito de la salmuera y observando un goteo evidente en el nivel de l quido durante un per odo de tiempo extenso NOTA Cerci rese de que no es un puente de sal el que est evitando el contacto con la sal Consulte la secci n Cuidado y limpieza del sistema de descalcificaci n de agua Si el sistema de descalcificaci n de agua no extrae salmuera inspeccione Que la boquilla y o el Venturi no est n sucios o defectuosos Que el empaque de la boquilla o el Venturi no est n defectuosos Que la boquilla y o el Venturi no est n bien asentados en la junta Otro defecto de la v lvula interna empaque del rotor rotor y disco arandela de onda Que no exista un drenaje restringido inspeccione los accesorios del drenaje y la manguera NOTA Si la presi n del sistema de agua es baja una manguera elevada podr a causar presi n regresiva evitando la extracci n de la salmuera 3 De nuevo presione el bot n RECHARGE recarga para llevar el sistema de descalcificaci
67. interrupci n prolongada en el suministro el ctrico el sistema de descalcificaci n de agua contin a operando como deber a para proporcionarle agua descalcificada Sin embargo la recarga podr an ocurrir a la hora equivocada del d a hasta que usted reajuste el control a la hora correcta del d a Caracter stica Servicio Diagn stico electr nico autom tico La computadora de control tiene una funci n de diagn stico autom tico para el sistema el ctrico excepto para la energ a de entrada y la medici n del agua La computadora monitorea los componentes electr nicos y los circuitos para una operaci n correcta Si ocurre un error un c digo de error aparece en la pantalla de control La tabla de C digos de Errores Error Codes muestra los c digos de errores que podr an aparecer y las razones posibles para cada c digo Ver Diagn stico electr nico iniciado manualmente para aislar el defecto a n m s ge com Servicio Funciones y servicio del tiempo de demanda electr nico C DIGO DE ERROR VISUALIZADO ERR 01 ERR 02 ERR 03 ERR 04 ERR 05 POSIBLE DEFECTO motor no eInterruptor eMotor no eInterruptor eControl funciona de posici n funciona de posici n o problemas en problemas en el cableado el cableado e Problemas en Control eControl eControl el cableado o interruptor e Interruptor de posici n e Control Para eliminar un c digo de error 1 Desconecte el transformador 2 Cor
68. ites de la temperatura del agua m n m x F Ritmo de flujo m ximo del suministro de agua pgm ENTRADA SALIDA cm wo un N 4114 104 8 cm 40 6 cm E Esto sistema se conforma a NSF ANSI 44 para los reclamos de capacidad espec fica verificados y substanciados por datos de prueba La prueba se llev a cabo usando bolitas grado cloro de sodio como sal regeneradora El ritmo de eficiencia es v lido solamente ante la dosis de sal m s baja La eficiencia de esto descalcificador fue evaluada de acuerdo con NSF ANSI 44 La cantidad de hierro removido puede variar seg n las condiciones La capacidad para reducir el hierro de agua clara es sustentada por los datos de las pruebas WQA El estado de Wisconsin requiere tratamiento adicional si el suministro de agua contiene m s de 5 ppm de hierro de agua clara Use Diamond Crystal RedeOut o Super Iron Out lo que mejora la eliminaci n del hierro Consulte la secci n Limpieza del hierro del agua del sistema de descalcificaci n Limites de presi n de trabajo en Canad 1 4 7 0 kg cm Sobre el sistema de descalcificaci n de agua Servicio Cuando el sistema descalcificador de agua est proporcionando agua descalcificada a esto se le llama Servicio Durante el servicio el agua dura fluye desde la tuber a de agua principal de la casa hacia el sistema de descalcificaci n de agua En el interior del tanque de resina del sis
69. l Si se dispone a llevar a cabo la instalaci n en el exterior debe tomar las medidas necesarias para asegurarse de que el descalcificador la instalaci n de plomer a el cableado etc est n tambi n protegidos de los elementos rayos del sol lluvia viento calor fr o de la contaminaci n vandalismo etc tal y como lo estar an si fueran instalados internamente La instalaci n en el exterior no es recomendada y anula la garant a Mantenga el descalcificador alejado de los rayos directos del sol El calor del sol podr a causar distorsi n u otros da os a las partes no met licas y podr a hacer da o a las partes electr nicas Instrucciones de instalaci n PLANIFIQUE LA INSTALACI N DEL DESCALCIFICADOR Lo primero que debe decidir es c mo instalar las tuber as que entran y salen del descalcificador Fijese en la tuber a de agua en el punto donde conectar el descalcificador La tuber a est soldada con cobre pegada con pl stico o roscada galvanizada Cu l es el tama o de la tuber a AADVE RTENCIA Use solamente fundente y soldadura sin plomo para evitar envenenamiento de plomo Consulte la Ilustraci n de instalaci n normal Usela como una gu a para planificar su instalaci n particular Cerci rese de dirigir el suministro de agua dura entrante al acoplamiento de admisi n de la v lvula del descalcificador La v lvula est marcada IN ENTRADA y OUT SALIDA ILUSTRACI N DE INSTALACI
70. la tuber a de la casa Si el agua que mezcla agua descalcificada con agua descalcificada no est conecada directamente a un grifo o dura Por ejemplo un grifo de una sola accesorio donde a usted le gustar a que estuviera conectado palanca de la cocina si la tuber a del p ngase en contacto con un plomero agua fr a de esegrifo est conectada al agua dura No hay sal en el tanque de la Revise si hay un puente de sal o si el tanque est vac o llene otra salmuera o hay un puente de sal vez con la sal recomendada Presione por tres segundos el bot n RECHARGE recarga para dar inicio a la recarga y restaurar el suministro de agua descalcificada El transformador est desconectado en el Inspeccione para cerci rese de que no ha habido una interrupci n tomacorriente de la pared o el cable del energ tica hacia el descalcificador de agua debido a algunas de descalcificador no est conectado Un estas condiciones y corrija seg n sea necesario Una vez restaurada fusible est fundido o se desconect en la energ a observe la visualizaci n en el plato y lea la secci n el circuito el ctrico hacia el tomacorriente Programaci n del control NOTA El tomacorriente para el interruptor del El tomacorriente est en un circuito que descalcificador debe estar permanentemente conectado para que no no puede ser desconectado pueda ser desconectado accidentalmente La v lvula de bypass manual est en Cerci rese de que la palanca
71. lation and operation bacteria could get into the softener For this reason sanitizing as follows is suggested when installing NOTE Sanitizing is recommended by the Water Quality Association for disinfecting 1 Be sure to complete all installation steps including programming the control Pour about 3 4 oz 1 2 tablespoons of common 5 25 unscented household bleach Clorox Linco Bo Peep White Sail Eagle etc into the brinewell Refer to illustration on page 5 IMPORTANT Press and hold for 3 seconds the faceplate RECHARGE button to start an immediate recharge RECHARGE begins to flash in the display The bleach will be drawn through the SPECIFICATIONS DIMENSIONS water softener and out the drain This process takes approximately 2 hours If after sanitization water from the house faucet tastes salty or has a slight color this is a preservative from the resin tank Turn on the cold soft water faucets and drain for a few minutes or until clear NOTE When the sanitizing recharge is over all remaining bleach is flushed from the conditioner and your house COLD water supply is fully soft immediately However your water heater is filled with hard water and as hot water is used it will refill with soft water When all the hard water is replaced in the water heater hot only and mixed hot and cold water will be fully soft If you want totally soft water immediately after the above recharge drain the water h
72. le with disabilities check out our Website today For the hearing impaired please call 800 TDD GEAC 800 833 4322 Extended Warranties ge com Purchase a GE extended warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories ge com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line today 24 hours every day or by phone at 800 626 2002 during normal business hours Instructions contained in this manual cover procedures to be performed by any user Other servicing generally should be referred to qualified service personnel Caution must be exercised since improper servicing may cause unsafe operation Contact Us ge com If you are not satisfied with the service you receive from GE contact us on our Website with all the details including your phone number or write to General Manager Customer Relations GE Appliances Appliance Park Louisville KY 40225 Register Your Appliance ge com Register your new appliance on line at your convenience Timely product registration will allow for enhanced communication and prompt service under the terms of your warranty should the need arise
73. ll In humid areas it is best to refill with less salt and more often to avoid forming a salt bridge see page 14 Never allow the softening system to use all the salt before you refill it Without salt you will soon have hard water Use clean water softening salts only at least 99 5 pure NUGGET PELLET or coarse SOLAR salts are recommended Do not use rock block granulated or ice cream making salts They contain dirt and sediments or mush and cake and will create maintenance problems ACAUTION Water softening salt with iron removing additives Some salts may have an additive to help the water softening system handle iron in the water supply Although this additive may help to keep the water softening system resin clean it may also release corrosive fumes that weaken and shorten the life of some water softening system parts GE recommends using only Diamond Crystal RedeOut brand salt Cleaning Iron Out of the Water Softening System Your water softening system takes hardness minerals calcium and magnesium out of the water Also it can control some see the Specification Guidelines section clear water iron With clear water iron water from a faucet is clear when first put into a glass After 15 to 30 minutes the water begins to cloud or turn rust colored A water softening system will not remove any iron that makes the water cloudy or rusty as it comes from the faucet called red water iron To take red w
74. los costes de env o o bien podr a solicit rsele que lleve el producto a un centro de servicio de GE autorizado para realizar la reparaci n En Alaska la garant a excluye el costo de env o o las visitas de servicio a su casa Algunos estados no permiten la exclusi n o las limitaciones de da os incidentales o consecuenciales Esta garant a da derechos legales espec ficos y usted podr a tener otros derechos que variar n de estado a estado Para saber cu les son sus derechos legales consulte a la oficina de asuntos del consumidor local o la oficina del Attorney General en su localidad Garante General Electric Company Louisville KY 40225 58 Soporte al Consumidor P gina Web de GE Appliances ge com Tiene alguna pregunta sobre su electrodom stico Pruebe la p gina Web de GE Appliances 24 horas al d a cualquier d a del a o Para mayor conveniencia y servicio m s r pido ya puede descargar los Manuales de los Propietarios o pedir piezas en l nea Solicite una reparaci n ge com El servicio de expertos GE est a tan s lo un paso de su puerta Llame al 800 GE CARES 800 432 2737 durante horas normales de oficina para solicitar su reparaci n Real Life Design Studio Estudio de dise o para la vida real ge com GE apoya el concepto de Dise o Universal productos servicios y ambientes que pueden usar gente de todas las edades tama os y capacidades Reconocemos la necesidad de dise ar para una gran gama
75. n Instale y apriete la tapa con sus manos solamente No apriete la tapa demasiado Sello del gt O aro t rico Soporte del filtro Filtro gt SS Tap n de S flujo Boquilla Venturi flujo Alojamiento de la Boquilla y el Venturi IMPORTANTE Cerci rese de que los agujeros peque os en la junta est n centrados directamente sobre los peque os agujeros en el alojamiento de la boquilla y el Venturi Instale con el lado que contiene n meros hacia arriba y el lado c ncavo hacia abajo 43 Sobre el sistema de descalcificaci n de agua 44 Operaci n normal Pantalla de control Durante la operaci n normal la hora actual del d a y AM o PM se muestra en el rea de la pantalla de control Cuando la computadora de demanda determina que una recarga es necesaria el mensaje RECHARGE TONIGHT recargue esta noche comienza a parpadear en la pantalla con la hora actual RECHARGE TONIGHT recargue esta noche parpadea hasta el momento de inicio de la pr xima recarga cuando cambiar a RECHARGE recarga el cual parpadea hasta que la recarga concluya Funci n Controles opcionales de recargado A veces es posible que usted desee o necesite una recarga iniciada manualmente Dos ejemplos Usted ha usado m s agua que de costumbre hu spedes en la casa lavado adicional etc y quiz s se quede sin agua descalcificada antes de la pr xima recarga Se le acab
76. n Instructions PLAN HOW YOU WILL INSTALL THE SOFTENER You must first decide how to run in and out pipes to the softener Look at the house main water pipe at the point where you will connect the softener Is the pipe soldered copper glued plastic or threaded galvanized What is the pipe size TYPICAL INSTALLATION ILLUSTRATION Soft water 24V 120 volt transformer outlet water to 1 female outside adapter 2 faucets E not supplied Bet NPT male adapter 2 l e gt O rings 2 IN Clips 2 O rings 2 GOES HERE Brinewell gt NOTE See Drain Hose Connections section Fig 1 CROSSOVER Use if water supply flows from the left Include single a or 3 valve bypass Hard water To softener inlet AWARN NG Use only lead free solder and flux to prevent lead poisoning See Typical Installation Illustration Use this as a guide when planning your particular installation Be sure to direct the incoming hard water supply to the softener valve inlet fitting The valve is marked IN and OUT OPTIONAL 3 VALVE BYPASS INSTALLATION ILLUSTRATION Hard water to outside Soft water R faucets lt XC 24V transformer 120 volt outlet S Outlet valve c 1 female adapter 2 not supplied V adapter 2 O rings 2 INLET Clips 2 3 Valve Bypass System For soft water service e Open the inlet an
77. n de agua al lavado regresivo Busque un flujo r pido de agua de la manguera de drenaje Un flujo lento indica que se ha obstruido un distribuidor superior un tap n de flujo de lavado regresivo o la manguera de drenaje 4 Presione el bot n RECHARGE recarga 9 para llevar el sistema de descalcificaci n de agua al enjuague r pido De nuevo busque un flujo r pido Permita que el sistema de descalcificaci n de agua enjuague por unos minutos para purgar cualquier salmuera que haya quedado en el tanque de resina durante la prueba del ciclo del proceso de salado 5 Para regresar el sistema de descalcificaci n de agua a servicio presione el bot n RECHARGE recarga Y 47 Cuidado y limpieza del sistema de descalcificaci n de agua 48 Inspeccione el nivel de almacenamiento de la sal y el rellenado Se necesita salmuera sal disuelta en agua para cada recarga El agua para hacer la salmuera es medida cuando entra al rea de almacenamiento de la sal a trav s de la v lvula del sistema de descalcificaci n de agua y el control Sin embargo usted debe mantener el tanque con sal Cu ndo rellenar con sal Inspeccione el nivel de la sal dos o tres semanas despu s de la instalaci n de su sistema de descalcificaci n de agua y peri dicamente de ah en adelante Rellene cuando el tanque est por debajo de 1 3 de su capacidad En reas h medas es mejor llenar con menos sal y hacerlo m s frecuentemente para evitar
78. ncipio De 15 a 30 minutos m s tarde el agua comienza a ponerse turbia o a cambiar a un color rojo ladrillo Un sistema de descalcificaci n de agua no remueve el hierro que causa que el agua se torne turbia o que adquiera el color rojo ladrillo cuando sale del grifo llamada agua rojo ladrillo Para extraer el hierro de esta agua se requiere un filtro u otro equipo GE recomienda que se usen las marcas de sal Diamond Crystal RedeOut con aditivo Iron Fighter para ayudar a mantener la capa de resina limpia del hierro Si su suministro de agua tiene hierro de agua clara es necesario que usted limpie peri dicamente la capa de resina GE recomienda usar un limpiador de capas de resina Super Iron Out para limpiar as eficientemente dicha capa especialmente cuando el contenido de hierro es alto Limpie la capa por lo menos cada seis meses o m s a menudo si comienza a aparecer hierro en su agua descalcificada entre limpieza y limpieza IMPORTANTE Es importante mezclar el limpiador de la capa de resina con agua siga las instrucciones del fabricante y vaciarlo en el dep sito de la salmuera ver p gina 33 y proceda a regenerar el descalcificador inmediatamente No vierta el limpiador de la capa de resina con la sal ya que no ser tan eficiente en su funci n de limpieza de la resina y puede causar da os al descalcificador si se deja en el tanque de la sal por un per odo de tiempo prolongado debido a que gases corrosivos
79. nozzle and or venturi dirty or defective defective nozzle and venturi seal nozzle and venturi not seated properly on gasket other inner valve defect rotor seal rotor and disc wave washer etc restricted drain check drain fitting and hose NOTE If water system pressure is low an elevated drain hose may cause back pressure stopping brine draw 3 Again press the RECHARGE 8 button to move the water softening system into backwash Look for a fast flow of water from the drain hose A slow flow indicates a plugged top distributor backwash flow plug or drain hose 4 Press the RECHARGE 9 button to move the water softening system into fast rinse Again look for a fast drain flow Allow the water softening system to rinse for a few minutes to flush out any brine that may remain in the resin tank from the brining cucle test 5 To return the water softening system to service press the RECHARGE button Care and cleaning of the water softening system ge com Checking the Salt Storage Level and Refilling Brine salt dissolved in water is needed for each and every recharge The water for making brine is metered into the salt storage area by the water softening system valve and control However you must keep the tank supplied with salt When to refill with salt Check the salt level a few weeks after you install the water softening system and periodically after that Refill when the tank gets less than 1 3 fu
80. nstallation by a licensed plumber and do not permit the use of the saddle valve For installation use plumbing code 248 CMR of the Commonwealth of Massachusetts PART NO WS35x10001 WS34X10015 WS07X10004 WS14X10002 WS14X10001 WS01X10002 WS32x10011 WS31X10022 WS31X10023 WS21xX10017 WS26xX10013 WS31x10021 WS33X10001 WS33X10007 WS31X10024 502 10009 WS32x10017 WS02x10027 WS32X10016 WS18xX10003 WS22X10016 WS22x10017 WS35X10035 WS15xX10035 WS35X10036 WS03X10006 515 10006 WS03X10007 WS03X10008 WS07X10002 WS07X10015 WS31X10018 WS02xX10029 WS02X10030 WS28xX10003 WS28xX10004 WS02x10012 WS02x1001 WS21x10003 WS03X10009 WS02x10014 WS31X10006 WS03X10010 WS26xX10002 WS19X10004 WS03x10011 WN PART DESCRIPTION O RING SEAL KIT DECAL FACEPLATE HOSE DRAIN 20 FT DISTRIBUTOR TOP DISTRIBUTOR BOTTOM RESIN 1 CU FT RESIN TANK 9 X 40 COVER TOP W LENS FACEPLATE CONTROL TRANSFORMER WITH POWER CORD COVER SALT HOLE WITH LABELS VAPOR BARRIER RIM COVER BRINEWELL W DECAL NUT BRINEWELL W DECAL SCREW TANK BRINE ROUND CLAMP HOSE ADAPTER HOSE GROMMET GROUND CLAMP KIT BRINE VALVE ASM FLOAT STEM amp GUIDE CLIP VALVE BODY BRINE CLIP SCREEN TUBING ASM BRINE TUBE ASM BACK COVER ELECTRONICS SPACER FACEPLATE SUPPORT RETAINER CLAMP CLAMP SCREW SPACER SWITCH PIN EXPANSION SCREW COVER VALVE WAVE SPRING ROTOR amp DISC ASM CAP VENTURI SEAL O RING
81. ol HARDNESS number setting too low Grains of hardness in your water supply have increased Absence of hardness minerals Water softening system is a demand unit Possible salt bridge Possible plugged nozzle and venturi Acidic water in copper plumbing Meter turbine stuck Sensor wire not plugged into the control No power to unit Mechanical defect Combination of soft water and too much detergent Valve drain hose pinched plugged elevated too high or otherwise restricted Nozzle and venturi dirty incorrectly assembled or damaged ge com What To Do Avoid using hot water during water softening system recharge because the water heater will refill with hard water See Automatic Hard Water Bypass During Recharge section page 13 Press the MODE button until arrow points to HARDNESS Be sure the number shown is the same as the actual grains per gallon hardness of your water supply See the Programming the Control section if a change in the setting is needed e Water hardness can change over time especially in well water To check have the water tested by a water analysis laboratory or call your local water department Adjust the HARDNESS number setting as needed This is normal Hardness in water gives it the abrasive feel you may have been accustomed to The slippery feel is the clean feel of soft water Does not use much salt to regenerate very efficient See the About the Water So
82. ompre un accesorio de compresi n tubo hembra de rosca de 1 4 0 63 cm x 1 2 1 27 cm de di metro externo y los tubos necesarios en una ferreter a local Roscas NPT de 1 4 0 63 cm Y Tubo de cobre de Leng etas 1 2 1 27 cm de di metro externo Clip A A no incluido Corte las Sta leng etas del accesorio de drenaje Accesorio de compresi n tubo de 1 4 0 63 cm NPT X 1 2 1 27 cm de di metro externo no incluido INSTALE LOS ACCESORIOS DE SOBREFLUJO DEL TANQUE DE SALMUERA Y LA MANGUERA e Inserte una arandela de goma en el agujero de 3 4 1 91 cm de di metro en el lado del tanque de salmuera como se muestra e Empuje el extremo del codo adaptador de la manguera hacia la arandela como se muestra e Adhiera la manguera use la manguera que sobre del Paso 4 al codo adaptador de la manguera Use una abrazadera de mangueras para mantenerla firmemente en su lugar e Ubique el otro extremo de la manguera en el punto de drenaje NO ELEVE esta manguera m s all del codo en el tanque de salmuera IMPORTANTE NO CONECTE EN T LA MANGUERA DE SOBREFLUJO HACIA LA MANGUERA DE DRENAJE DE LA VALVULA NOTA Este drenaje es para seguridad solamente Si el gabinete el tanque de salmuera se llena demasiado de agua el agua excesiva se lleva al drenaje Adaptador de la manguera 8 Abrazadera de la manguera No conecte hacia la manguera de drenaje
83. oquilla y el Venturi Es necesario que la boquilla y el Venturi est n limpios para que el sistema de descalcificaci n de agua funcione apropiadamente Esta peque a unidad ejecuta la succi n para mover la salmuera del rea de almacenamiento de sal hacia el tanque de resina durante la recarga Si est atascada con sal sucia etc el sistema de descalcificaci n de agua no funcionar y usted solamente tendr agua dura Para lograr acceso a la boquilla y al Venturi retire la tapa superior del sistema de descalcificaci n de agua Cerci rese de que el sistema de descalcificaci n de agua est en ciclo de servicio que no haya presi n de agua en la boquilla y el Venturi Luego mientras sostiene el alojamiento de la boquilla y el Venturi remueva la tapa Levante el soporte del filtro y el filtro luego la boquilla y el Venturi Lave y enjuague las partes en agua c lida hasta que est n limpios Si es necesario use un cepillo peque o para remover el hierro o la suciedad Tambi n inspeccione y limpie la junta NOTA Algunos modelos tienen un peque o tap n de flujo localizado en la boquilla y el Venturi y o un peque o filtro en forma de cono en el alojamiento Cerci rese de inspeccionar y limpiar estas partes si su modelo est equipado con ellos Con cuidado reemplace todas las partes en el orden correcto Lubrique ligeramente el sello del aro t rico con una grasa de silicona o con vaselina y coloque en su posici
84. original to assure plumbing integrity and ground continuity over the life of the home To valve inlet go Ground 77 clamp oy From valve outlet FLUSH PIPES EXPEL AIR FROM SOFTENER AND TEST YOUR INSTALLATION FOR WATER LEAKS ACAUTION To avoid water or air pressure damage to softener inner parts be sure to do the following steps in exact order Fully open 2 cold soft water faucets nearby the softener e Place bypass valve in bypass position by pushing the stem inward Fully open the house main water pipe shutoff valve Observe a steady flow from both faucets opened above FLUSH PIPES EXPEL AIR FROM SOFTENER AND TEST YOUR INSTALLATION FOR WATER LEAKS CONT Place bypass valve in the service position EXACTLY as follows KEEP SOFT WATER FAUCETS OPEN SLOWLY pull or slide the valve stem out toward the service position pausing several times to allow the softener to pressurize slowly After about 3 minutes open a HOT water faucet for 1 minute or until all air is expelled then close NOTE If water appears cloudy or has salty taste allow to run for several more minutes or until clear Close all water faucets Check your plumbing work for leaks and fix right away if any are found Be sure to observe previous caution notes Turn on the gas or electric supply to the water heater Light the pilot if applicable 8
85. os de interrupci n E Instalaci n entrega o mantenimiento inapropiada E Da o del producto causado por accidentes incendios inundaciones o incidentes de fuerza mayor E Fallas del producto si hay abuso mal uso o uso para Y otros prop sitos que los propuestos o uso para fines E Da o incidental o consecuencial a la propiedad causada por comerciales defectos posibles de este electrodom stico su instalaci n o reparaci n E Uso de esto producto en los sitios donde el agua es de calidad microbiol gicamente dudosa ni con aguas de E Producto no accesible para facilitar el servicio requerido calidad desconocida sin una desinfecci n adecuada antes o despu s del sistema el sistema puede utilizarse con aguas desinfectadas que puedan contener quistes filtrables EXCLUSI N DE GARANT AS IMPL CITAS Su nico y exclusivo derecho es la reparaci n del producto tal y como se indica en esta Garant a limitada Cualquier garant a impl cita incluyendo las garant as impl citas de comerciabilidad o adecuaci n para un fin determinado est n limitadas a un a o o el per odo de tiempo m s breve permitido por la ley Esta garant a se extiende al comprador original y cualquier comprador posterior de productos comprados para uso residencial dentro de Estados Unidos Si el producto est situado en un rea que no dispone de servicio por parte de un proveedor de servicio autorizado de GE podr a tener que hacerse cargo de
86. pecto caf o amarillo despu s de la instalaci n Agua de color caf amarillo Las part culas de resina aparecen en el agua potable y en los lavamanos Un sonido que usted puede escuchar El agua tiene burbujas de agua y est turbia Un c digo de error en el control Posible causa La v lvula de drenaje de la manguera est doblada y eso la est obstruyendo o est Qu hacer Cualquier restricci n en la manguera de drenaje podr a evitar la operaci n apropiada de la boquilla y el Venturi y reduce o evita demasiado elevada o su flujo est obstruido que se descargue la salmuera durante la recarga de alguna otra forma La boquilla o el Venturi est n sucios ensamblados incorrectamente o da ados La unidad no est limpia Baja presi n del agua Manguera de drenaje restringida La unidad estuvo inoperante por un periodo de tiempo Distribuidor agrietado Agua circulando desde la unidad hacia el drenaje durante la recarga Se introdujo aire en el sistema despu s de la instalaci n El cableado podr a haberse aflojado en el control e Ver la secci n de C mo limpiar la ensambladura de la boquilla y el Venturi en la p gina 43 Con la presi n de agua suspendida hacia el sistema de descalcificaci n desarme la ensambladura Inspecci nela limpiela y reemplace las partes que puedan estar da adas Cualquier part cula extra a rasgaduras picaduras etc en la v a podr a evitar la operaci n
87. que el tomacorriente el ctrico y el transformador est n en el interior de un recinto para protegerlos de la humedad Consulte la secci n Donde instalar el descalcificador para m s detalles A ADVERTENCIA No use con agua que sea microbiol gicamente insegura o de calidad desconocida sin llevar a cabo la desinfecci n adecuada antes o despu s del sistema El agua debe probarse peri dicamente para verificar que el sistema se encuentra funcionando satisfactoriamente Partes peque as restantes despu s de la instalaci n podr an representar un peligro de asfixia Deseche con toda seguridad Instrucciones de instalaci n DESEMPACADO E INSPECCI N Cerci rese de inspeccionar completamente el descalcificador en busca de da os durante el env o o partes que puedan haberse perdido Tambi n revise en busca de da os en la caja de env o P ngase en contacto con la compa a de transporte para cualquier reclamo por da o o p rdida El fabricante no es responsable por da os sufridos durante el tr nsito Las partes peque as necesarias para instalar el descalcificador se encuentran en una pieza de cart n termoconformada Para evitar la p rdida de las partes peque as mant ngalas en el paquete termoconformado hasta que usted est listo para usarlas Cerci rese de no descartar componentes que podr an estar escondidos en el embalage HERRAMIENTAS Y MATERIALES NECESARIOS PARA LA INSTALACION Alicates
88. r a de cobre o pl stico de 1 2 1 27 cm Consulte el Paso 4 Sal del descalcificador en una pepita limpia o bolita de agua es necesaria para llenar el tanque de agua salmuera Consulte el Paso 8 DONDE INSTALAR EL DESCALCIFICADOR e Coloque el descalcificador lo m s cercano posible a un sumidero o a otro punto de drenaje o columna de suministro Se recomienda que los grifos externos se dejen con agua dura para as ahorrar agua descalcificada y sal No instale el descalcificador en un lugar donde se pueda congelar Los da os debido al congelamiento no est n cubiertos por la garant a No instale el descalcificador donde pueda bloquear el acceso al calentador de agua o el acceso a la v lvula de cierre principal del agua Coloque el descalcificador en un lugar donde sea menos probable que ocurra da o causado por el agua si es que eventualmente ocurriese alguna fuga El fabricante no reparar ni pagar por da os ocasionados por agua Un tomacorriente de 120 voltios es necesario para conectar el transformador que viene incluido El descalcificador tiene un cable el ctrico de 10 pies Si el tomacorriente est colocado demasiado lejos hasta 100 pies use un cable calibre 18 para conectarlo Cerci rese de que el tomacorriente el ctrico y el transformador est n en el interior de un recinto para protegerlos de la humedad Cerci rese de que el tomacorriente est desconectado para prevenir un corte el ctrico accidenta
89. r unos minutos hasta que el agua se aclare NOTA Cuando la recarga de limpieza termine todo el cloro restante es purgado de su acondicionador y el suministro de agua FR A de su casa est completamente descalcificada inmediatamente Sin embargo su calentador de agua est lleno de agua dura y a medida que el agua caliente se use el calentador se llena con agua descalcificada Cuando toda el agua dura se reemplace en el calentador de agua el agua caliente y el agua mezclada caliente y fr a estar n completamente descalcificadas Si desea agua descalcificada inmediatamente despu s de la recarga anterior drene agua del calentador hasta que el agua salga fr a A ADVERTENCIA Si usted drena el calentador de agua tenga cuidado extremo ya que el agua caliente lo podr a quemar Apague el calentador de agua antes de proceder con el drenaje Capacidad calificada 11800 granos con 2 3 lbs de sal 25300 granos con 7 4 lbs de sal 30200 granos con 12 5 lbs de sal 5120 granos lb 2 3 lbs de sal 40 6 0 78 47 Vy 48 3 cm 120 7 Ritmo de eficiencia Cantidad de capacidad de resina alta Ibs cu pies Tama o nominal del tanque de resina pulg diam x altura Ritmo de flujo de servicio gpm Dureza m xima del suministro de agua gpg Hierro de agua clara m xima del suministro de agua ppm L mites de presi n de agua m n m x psi Ca da de presi n al ritmo de flujo de servicio psig L m
90. rain VAART ASEE not more than above the softener and 1 Is there electrical power to the outlet the water unobstructed If hose is above 8 see softening system transformer is plugged into page 8 step 4 If you do not find a problem with the visual checks continue below Electrical power was E off Reset the correct gt Investigate reason for time of day power loss CONTROL SHOWS WRONG TIME AND DAY AND OR IS FLASHING Check electrical REPAIR AS Do manual power to control NO POWER POWER _ NEEDED diagnostics CONTROL _ outlet pee to verify DISPLAY transformer BLANK gt proper power cable all POWER OKI OK CONTROL function connections DEFECTIVE CONTROL DISPLAY SHOWS CORRECT TIME _ Do manual AND DAY AND IS diagnostics STEADY 16 Service Manually Initiated Electronics Diagnostics Turbine Switches AFA 1 To enter diagnostics press and hold the MODE button until 000 shows in the display OR A the first 3 digits indicate water meter operation as follows Water Switch B Meter 000 steady soft water not in A use no flow through the meter OPEN A NEARBY SOFT WATER FAUCET 000 to 199 continual repeats display for each gallon of water passing through the meter Position O switch Sensor housing Turbine Turbine support and shaft outlet If you don t get a reading in the
91. rija el problema 3 Conecte otra vez el transformador 4 Espere por lo menos 6 minutos El c digo de error regresar si la raz n del c digo de error no ha sido corregida Servicio Sincronizador Descalcificador procedimiento de inspecci n del servicio Si usted no est recibiendo agua descalcificada y no aparece un c digo de error use el siguiente procedimiento para encontrar la fuente del problema Primero realice las siguientes inspecciones visuales INSPECCIONES VISUALES 1 Hay energ a el ctrica entrando hacia el tomacorriente en el cual el transformador del sistema de descalcificaci n de agua est conectado EL CONTROL MUESTRA LA HORA Y EL D A EQUIVOCADOS Y O EST INTERMITENTE NO HAY AGUA DESCALCIFICADA 2 Hay suficiente sal en el tanque de almacenamiento 3 Est la v lvula de bypass de descalcificaci n dirigiendo el agua para el servicio de descalcificaci n 4 Est la manguera de drenaje de la v lvula abierta hacia el drenaje a no m s de 8 pies 2 67 m por arriba del descalcificador y no tiene ninguna obstrucci n Si la manguera est m s de 8 pies 2 67 m por arriba del descalcificador ver la p gina 36 paso 4 Si usted no encuentra el problema con la inspecci n visual contin e m s adelante El suministro el ctrico ha sido interrumpido Reajuste la hora correcta del d a Investigue la raz n de la interrupci n el ctrica Inspeccione la energ a
92. rts in warm water until clean If needed use a small brush to remove iron or dirt Also check and clean the gasket NOTE Some models have a small flow plug located in the nozzle and venturi and or a small cone shaped screen in the housing Be sure to check and clean these parts if your model is so equipped Carefully replace all parts in the correct order Lightly lubricate the o ring seal with clean silicone grease or petroleum jelly and place in position Install and tighten the cap by hand only Do not overtighten the cap Y N Cap amp O ring seal gt O Screen 6 support Nozzle 3 Venturi Gasket gt Nozzle Venturi housing IMPORTANT Be sure small holes in the gasket are centered directly over the small holes in the nozzle and venturi housing Install with numbered side up concave side down Normal Operation Control Displays During normal operation the present time of day and AM or PM show in the control display area When the demand computer determines a recharge is needed RECHARGE TONIGHT begins to flash in the display along with the present time RECHARGE TONIGHT flashes until the next recharge start time then changes to RECHARGE which flashes until the recharge is over Feature Optional Recharge Controls Sometimes a manually started recharge may be desired or needed Two examples You have used more water than usual house guests extra washing etc
93. s due to a defect in materials or workmanship During this ten year limited warranty you will be responsible for any labor or related service costs What Is Not Covered E Service trips to your home to teach you how to use E Replacement of house fuses or resetting of circuit breakers ene prodiret E Damage to the product caused by accident fire floods or E improper installation delivery or maintenance acts of God E Failure of the product if it is abused misused altered used E Incidental or consequential damage caused by possible commercially or used for other than the intended purpose defects with this appliance its installation or repair E Use of this product where water is microbiologically unsafe E Product not accessible to provide required service or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied warranties of merchantability or fitness for a particular purpose are limited to one year or the shortest period allowed by law This warranty is extended to the original purchaser and any succeeding owner for products purchased for home use within the USA If the product is located in an area where service by a GE Authorized Servic
94. salida Abra la v lvula de bypass desde la izquierda Incluya una derivaci n sencilla o de 3 v lvulas salida del descalcificador Hacia la entrada del descalcificador Instrucciones de instalaci n ANTES DE COMENZAR Suspenda el suministro de gas o de energ a el ctrica que alimenta el calentador de agua en la posibilidad de que el calentador pueda drenarse mientras usted drena las tuber as Desconecte el suministro de agua hacia los tubos que han de ser cortados y drene las tuber as de agua de la casa e Abra los grifos de agua caliente y los de agua fr a en una ubicaci n baja NOTA Para una m s f cil instalaci n remueva la cubierta superior Libere los dos ganchos en la parte posterior de la cubierta Rote la cubierta hacia adelante y levante 1 INSTALE LA V LVULA DE BYPASS e Remueva el tap n pl stico de embalaje y el cable de la salida de la v lvula Turbina Salida de la v lvula Eje y soporte de la turbina NOTA Cerci rese de que la turbina y el soporte se encuentren firmes en sus posiciones en la salida de la v lvula Sople hacia la boquilla de la v lvula y observe que la turbina se encuentra rotando libremente e Empuje la v lvula de bypass lubrique los aros t ricos con grasa de silicona hacia ambas boquillas de la v lvula como se muestra Clips dl E 5 Clip Accesorio de drenaje Entrada gt V lvula de bypass
95. stema de descalcificaci n de agua fue instalado El sistema de descalcificaci n no est regenerando Agua turbia en la cristaler a en los lavaplatos autom ticos 50 Posible causa Usar agua caliente mientras el descalcificador de agua est en el proceso de regeneraci n El nivel de HARDNESS dureza del control es muy bajo Los granos de dureza en su suministro de agua han aumentado Ausencia de minerales de dureza El sistema de descalcificaci n de agua es una unidad de demanda Posible puente de sal La boquilla o el Venturi posiblemente obstruidos Agua cida en tuber as de cobre La turbina del medidor est atascada Alambre del sensor no conectado en el control No hay energ a el ctrica en la unidad Defecto mec nico Combinaci n de agua descalcificada y demasiado detergente Qu hacer Evite usar agua caliente mientras el descalcificador de agua est en el proceso de recarga porque el calentador de agua se rellenar con agua dura Consulte la secci n Circunvalaci n del agua dura autom tica durante la recarga p gina 41 Presione el MODE modo hasta que la flecha se ale HARDNESS dureza Cerci rese de que el n mero que aparece es igual que el n mero real de granos por gal n la dureza de su suministro de agua Consulte la secci n Programaci n del control si se necesita un cambio en los niveles La dureza del agua puede cambiar con el paso del tiempo especialm
96. te When the present time is correct press MODE to accept SET WATER HARDNESS NUMBER 1 Press the MODE button until HARDNESS appears in the A m display ma 2 Press UP or DOWN Y button to set your water hardness number in the display DOWN decreases the hardness value UP increases the hardness value HARDNESS NOTE Each press of a button changes the display by 1 between 1 and 25 Above 25 the display changes 5 at a time 25 30 35 etc Holding a button in changes the numbers at a rapid rate Installation Instructions SET WATER HARDNESS NUMBER CONT 3 When the display shows your water hardness in grains per gallon press MODE to accept NOTE If there is clear water iron in your water supply you will need to increase the hardness setting by 5 for each 1 ppm of clear water iron in your water supply You can get the grains per gallon gpg hardness of your water supply from a water analysis laboratory If you are on a municipal supply call your local water department Or call Legend Technical Services an independent laboratory to request a water hardness test kit at 1 800 949 8220 option 4 If your report shows hardness in parts per million ppm or milligrams per liter mg l simply divide by 17 1 to get the equivalent number of grains per gallon SET RECHARGE STARTING TIME 1 Press the MODE button until RECHARGE TIME appears in the an display RECHARGE NOTE A flashing 2 00 AM fa
97. tema de descalcificaci n de agua hay una pel cula o capa compuesta de miles de resinas pl sticas diminutas Cuando el agua dura pasa a trav s de la capa cada resina diminuta atrapa los minerales duros A esto se le llama intercambio de iones Es como un im n que atrae y atrapa metales Luego el agua sin minerales duros agua descalcificada o agua blanda fluye hacia la casa desde el sistema de descalcificaci n ge com Despu s de un per odo de tiempo la capa de resina se obstruye o se satura con los minerales duros y debe limpiarse Esta limpieza se denomina recarga La recarga comienza a las 2 00 AM ajustado en f brica por el control del sistema de descalcificaci n de agua y consiste en cinco etapas o ciclos stas son FILL llenado BRINING proceso de salado BRINE RINSE enjuague salado BACKWASH lavado regresivo y FAST RINSE lavado r pido Circunvalaci n autom tica del agua dura durante la recarga En casos de emergencia el agua dura est disponible hacia la casa durante los ciclos de recarga Llenado La sal disuelta en agua es llamada salmuera La salmuera es necesaria para limpiar los minerales duros de las diminutas part culas de resina Para formar la salmuera el agua fluye hacia el interior del tanque de sal durante el per odo de llenado Salado Durante el proceso de salado la salmuera se desplaza del rea del tanque de almacenamiento de la sal hacia el tanque de la resina La salmuer
98. tic parts e When turning threaded pipe fittings onto plastic fittings use care not to cross thread e Use Teflon Tape on all external pipe threads e Support inlet and outlet plumbing in some manner use pipe hangers to keep the weight off of the valve fittings Slide softener back into position Make final connections to the bypass valve and snap clips into place Be sure the clips for the bypass valve and NPT adapters snap into place Pull on the bypass valve and NPT adapters to make sure the parts are held securely in place 4 CONNECT AND RUN THE VALVE DRAIN HOSE Use the provided drain hose 20 length included to attach to the valve drain fitting To keep water pressure from blowing the hose off use supplied spring clamp to secure in place Cut the necessary length and use the remainder in Step 5 Locate the other end of the hose at a suitable drain point floor drain sump laundry tub etc that terminates at the sewer Check and comply with local codes IMPORTANT If more drain hose is needed it should be ordered from GE Parts at 800 626 2002 part number WS07X10004 The water softener will not work if water cannot exit this hose during recharge Tie or wire the hose in place at the drain point High water pressure will cause it to whip during the back wash and fast rinse cycles of recharge Also provide an air gap of at least 1 1 2 between the end of the hose and the drain
99. ubricate o ring seals with silicone grease into both ports of the valve as shown e Snap the 2 large plastic clips in place from the side as shown MOVE THE SOFTENER ASSEMBLY INTO INSTALLATION POSITION Before sliding softener in position be sure the installation surface is level and smooth Sharp objects under the tank may puncture it If needed place the tank on a section of 3 4 thick minimum plywood Then place shims under the plywood as needed to level the softener Slide softener into position Installation Instructions PLUMB IN AND OUT PIPES TO AND FROM SOFTENER ACAUTION Observe all of the following cautions as you connect inlet and outlet plumbing See Typical Installation Illustration BE SURE INCOMING HARD WATER SUPPLY IS DIRECTED TO THE SOFTENER VALVE INLET PORT If house water flow is from the left use a plumbing crossover as shown in Typical Installation Illustration If house water flows up from the floor level turn the bypass valve upside down as shown Turn bypass valve upside down to connect to floor level plumbing e With the softener in place determine the correct length of piping required to connect the household plumbing to the NPT male adapter e Remove softener from installation space If making a soldered copper installation do all sweat soldering before connecting pipes to the NPT adapters and bypass valve Torch heat will damage plas
100. ultas posteriores La instalaci n apropiada es la responsabilidad del instalador Las aver as del producto causadas por una instalaci n inadecuada no est n cubiertas por la garant a Debe existir una v lvula de cierre disponible o se debe agregar una cerca al punto de instalaci n RECOMENDACIONES IMPORTANTES PARA LA INSTALACION En el estado de Massachusetts la instalaci n debe ajustarse al C digo de Plomer a 248 CMR Consulte a su plomero certificado Use solamente fundente y soldadura sin plomo para todas las conexiones de condensaci n soldadas seg n los c digos estatales y federales aplicables Conecte el descalcificador en la tuber a de suministro principal antes del calentador de agua NO HAGA PASAR AGUA CALIENTE A TRAVES DEL DESCALCIFICADOR La temperatura del agua que pase a trav s del descalcificador debe ser menor de 49 C 120 F descalcificador No lo coloque boca arriba ni lo deje caer ni lo arrastre ni lo apoye en protuberancias La presi n de entrada m xima permitida es de 125 psi Si la presi n durante el d a es por encima de 80 psi la presi n nocturna podr a exceder el m ximo Use una v lvula reductora de presi n para reducir el flujo si es necesario Agregar una v lvula reductora de presi n podr a reducir el flujo El sistema de descalcificaci n funciona solamente con 24 voltios 60 Hz Cerci rese de usar exclusivamente el transformador incluido Cerci rese de
101. undada hacia los grifos durante la regeneraci n Si no es necesario ning n cambio siga al paso 3 Para cambiar el tiempo de inicio de la recarga siga el paso 2 2 Oprima el bot n UP A o DOWN Y para fijar la hora de inicio deseada para la regeneraci n Cerci rese de ajustar AM al igual que lo hizo para ajustar la hora del d a NOTA Cada vez que usted oprima los botones la hora cambia por 1 hora Mantener los botones oprimidos cambia la hora a un ritmo m s r pido 3 Oprima el bot n MODE modo para aceptar AJUSTES OPCIONALES DE CONTROL La pantalla del controlador ofrece varias opciones y caracter sticas DIAGN STICO ELECTR NICO DEL SISTEMA Esta visualizaci n contiene informaci n sobre el diagn stico del sistema para ayudar a la soluci n e identificaci n de problemas del descalcificador Ver la p gina 46 Para ingresar al sistema de diagn stico presione y sostenga presionado el bot n MODE por 3 segundos Para regresar a la pantalla normal presione el bot n MODE dos veces EFICIENCIA DE LA SAL Cuando la funci n de SALT EFFICIENCY eficiencia de la sal est encendida ON la unidad operar a una eficiencia de sal de por lo menos 4000 granos de dureza removidas por libra de sal Este modo de operaci n es el nivel m s eficaz para el uso de la sal dado que el sistema tiende a regenerarse m s a menudo con menos uso de sal Fijar la funci n en la posici n de apagado OFF tiende a
102. ust be properly installed and located in accordance with the Installation Instructions before it is used Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break it Do not attempt to treat water over 100 F Do not install in direct sunlight Excessive sun or heat may cause distortion or other damage to non metallic parts Properly ground to conform with all governing codes and ordinances Use only lead free solder and flux for all sweat solder connections as required by state and federal codes The water softening system requires a minimum water flow of three gallons per minute at the inlet Maximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nighttime pressure may exceed the maximum Use a pressure reducing valve to reduce the flow if necessary VA D a ON 2 SAVE THESE INSTRUCTIONS Softener resins may degrade in the presence of chlorine above 2 ppm If you have chlorine in excess of this amount you may experience reduced life of the resin In these conditions you may wish to consider purchasing a GE point of entry household filtration system with a chlorine reducing filter AWARNING Discard all unused parts and packaging material after installation Small parts remaining after the installation could be a choke hazard 7 READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY
103. var a cabo y repare inmediatamente si encuentra alguna Cerci rese de observar las notas de precauci n anteriores e Conecte el suministro de gas o el ctrico hacia el calentador de agua Encienda el piloto si es aplicable 8 AGREGUE AGUA Y SAL AL TANQUE DE SALMUERA e Levante la tapa del orificio de la sal Agregue aproximadamente 3 galones de agua al tanque No la agregue al dep sito de salmuera e Llene el tanque con sal de PEPITAS BOLITAS o sal gruesa SOLAR con una pureza de 99 5 o mayor No use sal en roca en bloques granulada ni de helado para descongelar hielo ni sal con aditivos que elimine el hierro excepto la marca Diamond Crystal RedeOut La capacidad de almacenamiento de sal es de aproximadamente 200 libras Mantenga la tapa del agujero de la sal en su lugar a no ser que se encuentre realizando servicios de mantenimiento o llenando de sal NOTA Si el descalcificador se instala en un s tano h medo o en un rea demasiado h meda es mejor llenar el tanque con menos sal y hacerlo m s frecuentemente De 80 a 100 libras de sal durar n varios meses dependiendo de la dureza del agua el tama o de la familia y del modelo del sistema de descalcificaci n Instrucciones de instalaci n 9 CONECTAR A LA FUENTE EL CTRICA Para lograr acceso al transformador ensambladura del cable el ctrico remueva la cubierta del agujero de sal del descalcificador Desengrape las orejillas en
Download Pdf Manuals
Related Search
Related Contents
und Aufstellanleitung Fireplace user instruction Cheminée mode d •71+72_SMART BASE_English UK manual de instrucciones MANUAL DE INSTRUCCIONES Sensor Pick UP Magnetico Setup and User`s Manual Série AMJ - SMC ETech Moog Videolarm IRHP75TF Optimus CTR-114 Cassette Player User Manual Intervention spécifique à la migration dans le domaine Copyright © All rights reserved.
Failed to retrieve file