ETA Systems ETA-ECS6RM Recording Equipment User Manual

image

Contents

1. Example 3 Three ETA ECS6RM wired to 18 ETA ECM20 or ETA ECM20M Modules Ce m os oO O O OQ O e e t3 t00 E00 800 1700 800 1200 100 i 1 OO 1 OO 1 AO 1 AO T OO o C00 1100 1100 11200 1200 1200 i Example 4 ETA ECS6RM wired to 4 ETA ECM20 or ETA ECM20M Modules that are in the ECM RACEWYG and a separate ETA 15SH and ETA 20SH housing c m Nm cO E o ooo 00000 4 C EEI O 1400 3700 t00 i00 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 17 ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N EXAMPLES ETA ECM20 M20RW MODULE WIRING CONFIGURATIONS The ETA ECM20 M20RW is designed to be mated with the ECM RACEWYG housing and the ETA ECS6RM contro
2. COO Ss SS S Example 2 ETA ECS6RM wired to six ETA ECM20 or ETA ECM20M Modules using DCV 5 24V or a Switch for remote activation External DC IN Trigger or External Contact Switch ieee samen a ee oO eje r se 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 16 ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer N SYSTEMS N Leading by Design
3. Eg ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer N SYSTEMS N Leading by Design REAR PANEL 1 ECM Control Ports Up to 6 AC Main circuits can be activated or monitored by the ETA ECS6RM Each ECM control port connects to one of the following ECM modules ETA ECM20M ETA 15SH ETA 20SH and the ETA ECM20 For connection between the ETA ECS6 and an ECM module use a 5 conductor cable that is a minimum of 22 gauge wire We suggest using CAT5 cable due to the common availability Pay special attention to the port connections and DO NOT MIS WIRE or damage may occur The distance between the ETA ECS6RM and an ECM module can be up to 1000ft 5VDC CHANNEL 6 TO FROM ECM 20 G Circuit Ground V AC Voltage Status Signal A AC Current Status Signal G v A D D Fault Status Signal all signals are of low voltage and current TRIGGER STATUS VOLTAGE SIGNAL 2 Relay Contacts Each Channel of the ETA ECS6RM also has a Relay contact that works in conjunction with the ECM control port Sequencing and timing of these connections are the same as the corresponding ECM channels Example Sequence 1 ECM Port output works at the same times CH 1 Relay contact Note All ECM modules can be triggered using the Relay contacts to activate the ECM module See ECM module for details CHANNEL RELAY CONTACTS NO NORMALLY OPEN Ra A NO
4. A No A NO A NO A NO A NO CH6 CH6 CH6 CH8 CH8 CH6 3 ETA ECS6RM Remote Activation Connections The ETA ECS6RM can be activated via four methods Two of them are via the Remote Activation ports The others are via the Front Panel Activation Switch and ECS KSW6 Key Panel Switch 1 External Switch ExtSw The ETA ECS6RM can be remotely activated from hundreds of feet away A simple low voltage current single contact switch can be applied to the two terminal connections marked ExtSw on the Remote Activation port When these two points are shorted together the unit will be active when released the unit will shut Off When the contacts are shorted together the Front Panel Activation Switch is overridden by the External Switch The External Trigger LED will illuminate on the Front panel indicating the status of the activation mode 2 Remote Voltage Trigger The ETA ECS6RM can be remotely activated from hundreds of feet away using a DCV for activation DC voltages ranging from 3V DC to 24V DC can be applied to the two terminal connections on the Remote Activation port marked RMT V IN and GND When these two points have the proper voltage applied the unit will be active when the DC voltage is removed the unit will shut Off When the proper DC voltage is applied the Front Panel Activation Switch is over ridden The External Trigger LED will illuminate on the Front panel indicating the status of the activation mode
5. ETA ECS6RM ETA Electrical Control Sequencer N SYSTEMS N Leading by Design SYSTEMS Leading by Design N ETA ECS6RM Electrical Control Sequencer B ETA ECSERM Sequencer 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 M ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N TABLE OF CONTENTS SC RR 3 aerate oles To eec PE 5 Front Panel of ETA ECSORM uide qi cci o pedit Sie ieee 7 Rear Panel oFETACEGSORM scidit percipe tpa ten due ied rt acit ee a ee 9 Wie 8 EPI HR ice ca sceeeanswesiea n ace dapse a E E O EERS 1 AP GNL18 LED Gooseneck Lamp iv ice mae cette ote tyr ti eco ee Ag iei pecu hd en p ta sd MESE XR META Mines 1 ETA 15SH Standalone 15A Electrical Control Module ssssssssssse ee 2 ETA 20SH Standalone 20A Electrical Control Module ssssssse mee 4 ECM RACEWY ECM Raceway Hotsihg icit dep esti Doe bxc ie e ecd ueu eco nv eda D pe Den 4 ECMESBP Raceway Blank Plate item etie Ever erste pesi Ere peers bei ere ad EE EEEE 5 ETA ECM20M Electrical Control Module sssssssssssee eene rennen 5 ETA ECM20 Electrical Control Module Without Current Monitoring 5 ECS KSW6 Remote Key Switch and Monitor ssssssssssssssssssseeeneeeeeeneeeeee tenente eene eene tns 6 ET
6. Schools Home Theaters Office Buildings Sports Bars Industrial Facilities 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 5 ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer N SYSTEMS N Leading by Design FRONT PANEL S ETA SELECTED CHANNEL lt gt ETA ECSEBRM ISENTS CHANNEL SELECT CHANNEL MONITORING SELECTION ena Power Conditioner amp Sequencer 1 System Activation Switch To activate or deactivate the system sequence press the momentary switch once There must be at least one ECM Electrical Control Module connected for a sequence to occur If there are no Channel Status LEDs illuminated or voltage reading no sequence will occur The unit will only sequence through the number of ECM modules connected Note If there are ECM modules connected and the Channel Status LED are illuminated but the Activation Switch has no effect the unit may be in External Trigger Mode Refer to Channel Status LEDs and Relay Contacts sections 2 Unit Activation Mode LEDs e System ON LED When the ETA ECS6RM is activated the System ON LED SYTEM ON will illuminate EXTERIOR a e Exterior Trigger Mode If an External Trigger Voltage or Switch is applied to TRIGGER activate the ETA ECS6RM the Exterior Trigger Mode LED will be illuminated MODE SYSTEM Note When LED is ON the System Act
7. 3 Front Panel Activation Switch See Front Panel Activation Switch for details 4 Remote Control Key Switch ECS KSW6 This an optional accessory item that allows you to activate lock out and monitor the system from up to 1000ft away See Remote ECS KSWG6 for details 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 9 ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design ousa nanei CHANNEL RELAY CONTACTS T cvv CHANNEL 1 ID TEDM ECM20 TO FROM M3O TO FROM CM 20 Her r Tao NORMALLY DPEN um iib dlik idk dlik dikki pn iur SS os oun na wan suns ow 4 Trigger Switches Up to three ETA ECS6RM units can be daisy chained together giving you 18 sequenced outputs To do so you need to set the timing sequence of each unit There are four dip switches that determine the position of the unit and the delay between sequencing Follow the steps for setup Master or Slave Unit Determine if you are daisy chaining two or three units together Choose the position of the sequence in perspective to the equipment you are activating The first unit will be known as the Master Unit all others are Slave Units A amp B switches determine the position of the unit and sequence timing Follow the chart to the right and on the back of the ETA ECS6RM for the settings W
8. A Telephone 800 321 6699 Fax 800 996 3821 22 ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer N SYSTEMS N Leading by Design NOTES 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 23 ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer installer industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications if any This warranty shall extend from the date of purchase for a period of one year Additionally fuses and lamps carry no warranty ETA Systems will Solely at its discretion replace at no charge or repair free of charge defective parts or products when the product has been applied and used in accordance with our published operation and installation instructions We will not be responsible for defects caused by improper storage misuse including failure to provide reasonable and necessary maintenance accident abnormal atmospheres water immersion lightning discharge or malfunctions when products have been modified or operated in excess of rated power altered serviced or installed in other than a workmanlike m
9. and up They can be caused from fluctuations from the utility company s power lines or industrial equipment turning On and Off on the same power leg of the building s incoming AC EVS Protection If an ECM Module is connected to the ETA ECS6RM the ETA ECS6RM has built in intelligence that monitors the AC lines from the ECM modules and will inform you of potentially damaging voltages If the AC Mains voltage is between 101VAC and 107VAC or 128VAC and 132VAC the display will flash an error code indicating a potential fault has occurred and you should check sensitive equipment If an extreme voltage swing occurs above 128VAC or below 101VAC the Extreme Voltage Shutdown EVS protection circuit will automatically turn all remote ECM modules off until the system is manually reset The EVS feature can be defeated if required via the ETA ECS6RM EVS bypass switch Over Current Protection In the case of excessive current draw at the ECM module an internal Slow Blow fuse will open protecting the devices plugged into the ECM module Note This fuse must be changed by a qualified service technician 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 11 ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N ECM INDICATOR AND PART DESCRIPTION 1 Trigger Status Port Pin Identification all
10. fire or electrical shock Ensure that the safety ground terminal is connected to a proper ground Never connect the ground to a gas pipe as a catastrophic disaster may result Be sure the installation of the product is stable avoid slanted surfaces as the product may fall and cause injury or property damage CAUTION WHEN THE DEVICE IS IN USE Never place heavy objects on the product causing it to fall and or break resulting in personal injury and property damage In addition the product itself may fall and cause injury and property damage Contact ETA Systems for instructions on cleaning the inside of the unit Large accumulations of dust inside the unit may result in heat buildup and fire Ensure that the power supply plug is securely plugged into the wall outlet Never allow dust to accumulate on the power plug or inside the wall outlet When cleaning the unit or the unit is not to be operated for an extended time period unplug the power cord from the wall 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 zz ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer SN SYSTEMS N Leading by Design INTRODUCTION Thank you for purchasing the ETA Systems ETA ECS6RM Intelligent AC Power Sequencer The ETA ECS6RM Electrical Controller Sequencer with Six Timing Sections with Remote Monitoring modul
11. A ECS6RM Configurations nennen eene eere nennen nenne ener enne enn enne ens nnns 7 ETA ECM20 ETA ECM20M Wiring Configurations eene nns 9 Troubleshooting e P danse sae sduameuuttereaaunss 20 SPO CME Ca OMS suere costes tose ate veces a gestae pec eats ean cote eme ue M EM E 22 Yaranan EE 24 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 a ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer N SYSTEMS Leading by Design SAFETY INSTRUCTIONS oN Oa FF WN 10 11 12 13 14 15 16 17 The lightning flash with arrowhead symbol within an CAUTION equilateral triangle is intended to alert the user to the RISK OP ELECTHIC EHOCK presence of uninsulated dangerous voltage within the DO NOT OPEN product s enclosure that may be of sufficient magnitude 7 to constitute a risk of electric shock to persons RISQUE DE DECHARGE ELECTRIQUE ATTENTION NE PAS OUVRIR The exclamation point within an equilateral triangle is WARNING intended to alert the user to the presence of important TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK operating and maintenance servicing instructions in the DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE literature accompanying the product Read these instructions Keep these instructions Heed
12. Activation LED is Illuminated Green but the Voltage display is not on Check the wiring between the ETA ECS6RM Channel and the ECM module V A and D must be in the correct polarity Issue 7 No Current Reading at the ETA ECS6RM Meter Reads nA Possible Cause 1 An ETA ECM20 Module is connected This module does not support current read out Possible Cause 2 Check Issues 1 4 first Possible Cause 3 Current Draw of ECM Module must exceed 500mA to register Possible Cause 4 Proper Channel is not selected for viewing Possible Cause 5 Channel Activation LED is Illuminated Green but the Current display reads nA Check the wiring between the ETA ECS6RM Channel and the ECM module V A and D must be in the correct polarity Issue 8 Not All Channel Status are Illuminated Red or Green Probable Cause No ECM Module connected to the ETA ECS6RM Note For any of the 6 Channel Status LEDs to illuminate a ECM Module must be connected to the ETA ECS6RM It ok to use only some of the six channels and not have all channels illuminated Issue 9 Sequence Timing or Slave Master Unit Dip Switches Has Been Adjusted but No Effect Has Taken Probable Cause After changing of the DIP switches you must cycle the ETA ECS6RM for the settings to take effect Issue 10 Current Meter Reads nA on A Selected Channel but the Channels is Functioning Probable Cause 1 ETA ECM20 module connected Only ETA ECM20M ETA 15SH and ETA 20SH modules
13. As a reference It takes around a foot of wire between ETA ECM20 modules if they are wired on the same incoming AC Main It is highly recommended that the wire needed for the job is carefully measured It may take more than one ECM ACIN wire kit depending on how many AC Mains and the distance from the AC Mains Panel It is not necessary to use Atlas ECM ACIN wire kit as long as it is 12 gauge and UL listed ETA ECM20M 20A AC Control Module The features data wiring and the functionality of the ETA ECM20M are the same as the ETA 20SH and the ETA 15SH The ETA ECM20M is designed to be installed in the ECM RACEWYG Read above for operation details E SYSTEMS N Leading by Design ETA ECM20M 20A AC Power Module Suppressor amp Conditioner z Gp Engineered in the USA Made in China ETA SYSTEMS 1601 Jack McKay Bivd Ennis TX 75119 U S A wwwetasys com e 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 14 ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer N SYSTEMS N Leading by Design ETA ECM20 20A AC Control Module No Current Monitoring The ETA ECM20 does not support the same Current monitoring or EMI RFI Filter feature as the ETA ECM20M ETA 20SH and the ETA 15SH models have However it does support AC Spike and Surge Suppression AC Mains Voltage monitoring EVS circuitry and Remote Activ
14. all warnings Follow all instructions Do not use this device near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions Do not install near any heat sources such as radiators heat registers stoves or other device including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong are provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the device Only use attachments accessories specified by the manufacturer Use only with the cart stand tripod bracket or table specified by the manufacturer or sold with the device When a cart is used use caution when moving the cart device combination to avoid injury from tip over Unplug this device during lightning storms or when unused for long periods of time Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled objects have fallen into the device the
15. anner The original sales invoice should be retained as evidence of purchase under the terms of this warranty All warranty returns must comply with our returns policy set forth below When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any non warranty work is performed In the event of replacement or upon completion of repairs return shipment will be made with the transportation charges collect EXCEPT TO THE EXTENT THAT APPLICABLE LAW PREVENTS THE LIMITATION OF CONSEQUENTIAL DAMAGES FOR PERSONAL INJURY ETA SYSTEMS SHALL NOT BE LIABLE IN TORT OR CONTRACT FOR ANY DIRECT CONSEQUENTIAL OR INCIDENTAL LOSS OR DAMAGE ARISING OUT OF THE INSTALLATION USE OR INABILITY TO USE THE PRODUCTS THE ABOVE WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ETA Systems does not assume nor does it authorize any other person to assume or extend on its behalf any other warranty obligation or liability This warranty gives you specific legal rights and you may have other rights which vary from state to state SERVICE Should your ETA ECS6RM require service please contact the ETA Systems warranty department at 1 877 689 8055 ext 277 to obtain an RA numb
16. ar system has been designed to meet most installation requirements for AC power distribution equipment power conditioning and surge suppression protection The compact 1RU unit features six sequential timing sections that can be activated via the unit or remotely Up to three ETA ECS6RM units can be daisy chained together with independent trigger timing settings giving you a total of 18 sequence triggered outlets The ETA ECS6RM unit is the activation controller monitor portion of the system and requires a 120V AC Mains ECM Electrical Controlled Module module for each triggered output A variety of remote ECM AC modules are available to meet different installation requirements The ETA ECS6RM can also monitor up to six independent 20A AC main lines both voltage and current readings can be viewed via the laboratory grade meters on the front panel The ETA ECS6RM has built in intelligence that monitors the AC lines and will inform you of potentially damaging voltages If the AC Mains voltage is between 101VAC and 107VAC or 128VAC and 132VAC the display will flash an error code indicating a potential fault has occurred and sensitive equipment should be checked If an extreme voltage swing occurs above 128VAC or below 101VAC the Extreme Voltage Shutdown EVS protection circuit will automatically turn all remote ECM modules Off until the system is manually reset The EVS feature can be defeated if required The ETA ECS6RM also features 6 sequenced independen
17. ation In certain applications ETA Systems suggests using an ETA ECM20 Module vs an ETA ECM20M in places where some of the features would be redundant because of the electrical location of the ECM module This would be a cost savings to use a less expensive ECM module where redundant circuitry is not needed Example One 20A Incoming AC line Two sequenced AC outlets are required use one ETA ECM20M and one ETA ECM20 module wired in parallel Explanation If the AC Mains system required a sequenced outlet and did not require more than 20A of service for a portion of the AC power system an ETA ECM20M module can be placed in parallel with an ETA ECM20M module It is not necessary to have Amperage readings from both ECM Modules because you can read the current from the ETA ECM20M Module which could be in parallel with an ETA ECM20 Module which is on the same incoming AC line as the ETA ECM20M module They would have the same current reading because they are in parallel Also the EMI and RF filtering are across the same AC line leg so both ECM Modules connected to that line are filtered no need to have redundant filtering Note In this wiring configuration you still get the Voltage monitoring to see if the module is active and have extra surge protection See ECM Module wiring configurations Intertek 4004862 E ETA TRIGGER VOLTAGE o Winn SYSTEMS N Leading by Design STATUS sia C MANUAL ETA ECM20 D 20A AC Power Module S
18. device has been exposed to rain or moisture does not operate normally or has been dropped WARNING To reduce the risk of fire or electric shock this device should not be exposed to rain or moisture and objects filled with liquids such as a vase should not be placed on this device To completely disconnect this equipment from the mains disconnect the power supply cord plug from the receptacle The mains plug of the power supply cord shall remain readily operable 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 Eug ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design CAUTION WHEN INSTALLING THE PRODUCT Plugging in or unplugging the power cord with wet hands may result in electric shock Never move the device with the power cord plugged into the wall as damage to the power cord may result When unplugging the cord from the wall grasp the plug NOT the cord Never install this device in humid or dusty locations nor in direct sunlight near sources of heat or in areas where sooty smoke or steam are present Fire and electric shock may result Keep all sides of the device at least 31 2 away from objects that may obstruct air flow to prevent the unit s internal temperature rise WARNING WHEN THE DEVICE IS IN USE To prevent electric shock do not remove the devic
19. e Suppressor designed to be a standalone Single Housing SH unit that can be placed up to 1000 ft away from the ETA ECS6RM To make full use of the ETA 15SH features the ECM must be connected to the ETA ECS6RM controller to activate features such as AC Mains voltage monitoring load current monitoring and Extreme Voltage Shutdown EVS ETA 15SH Remote AC Power Suppressor amp Conditioner ETA 20SH Standalone 20A Power Conditioner and AC Spike Suppressor This Electrical Control Module ECM is a 20A Power Conditioner and AC Spike Suppressor designed to be a standalone Single Housing SH unit that can be placed up to 1000 ft away from the ETA ECS6RM The ETA 20SH has several advanced features incorporated refer to the individual data sheet for full instructions and specifications on the module Many of the ETA 20SH features and connections are the same as the ETA 15SH ETA 20SH Mounting Tabs There are two sets of mounting tab rails Theses rails are designed to be breakaway if they are not needed Simply bend the tab back and forth until the tab breaks away ETA ETA 20SH 20A Sequencer Module INTERNAL FUSE 20A 250V 3AB SLOW BLOW 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 13 ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N ECM RACEWY6 ECM Housi
20. e cover as there are high voltage components inside Refer all servicing to ETA Systems Should any of the following irregularities occur during use immediately switch off the power disconnect the power cord from the AC outlet and contact ETA Systems Do not to attempt to continue operation of the device as this may cause fire or electric shock Smoke or strange smell coming from the unit f the device falls or the case is damaged f water or any metallic objects fall into the device f the power supply cord is damaged in any way f the device is malfunctioning Do not insert or drop metallic objects or flammable materials into the ventilation holes of the device s cover as this may result in electric shock or fire Do not place any metallic objects or containers with liquid on the top of the device If any liquid spills into the unit fire or electric shock may result Never operate this device or touch the power supply cord during an electrical storm electric shock may result Never exceed the wattage on the product when connecting equipment Fire and or property damage may result Operate the device only with the voltage specified on the unit Fire and or electric shock may result if a higher voltage is used Do not modify kink or cut the power cord Do not place the power cord in close proximity to heaters and do not place heavy objects on the power cord including the device itself doing so may result in
21. e same as an Ethernet cable Do not mis wire the connector or damage may occur 8 DC Power IN The ETA ECS6RM comes with a universal power supply that operates from 100V 240VAC The 24VDC output connects to the DC input jack A cable tie can be used with the slot above the DC jack to secure the cable to the chassis 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 10 ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer SN SYSTEMS Leading by Design ECM DATA WIRE AND DISTANCE There are four different types of ECM Modules that require the same interface connectivity to the ETA ECS6RM All ECM Modules can be interfaced with the ETA ECS6RM For connection between the ETA ECS6RM and an ECM module use a 5 conductor cable that is a minimum of 22 gauge wire We suggest using CAT5 cable due to the common availability and low cost Pay special attention to the port connections and DO NOT MISWIRE or damage may occur The distance between the ETA ECS6RM and the ECM Module can be up to 1000ft ECM MODULE ACTIVATION WITHOUT USING ETA ECS6RM OR AN ECS 3 CONTROLLER Any of the ETA ECM20 ETA ECM20M ETA 15SH or the ETA 20SH Modules can be triggered to activate without using an ECS type Controller Any DCV supply will activate the ECM by applying DCV 5 24VDC to the and GND terminals An external switch will a
22. ence EMI generated by items such as electric motors and switching power supplies The benefit of these filters can be seen on video products or audibly by reducing static pops and external signal interference High line can also be known as surges Surges usually are a slower steady state rise in voltages ranging from 128VAC and up They can be caused from fluctuations in the utility company s power lines or industrial equipment turning On and Off and on the same power leg of the building s incoming AC L u ow line is also known as brownouts This happens when the AC Mains drops below 107VAC Most of the time it is caused by the ility company not being able to supply enough power during heavy utility consumption time periods such as heat waves Another factor would be from voltage drops in AC lines due to long transmissions The ETA ECS6RM will inform you if any of these conditions occur Extreme variances in Unstable AC Mains voltage are one of the main reasons for equipment failure The ETA ECS6RM offers Intelligent Sequenced Power Management control making it the most flexible effective power management protection system on the market today 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 EX m ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N ETA ECS6RM KEY FEATURES 6 S
23. equencer Timing Sections 1 3 or 6 Second Intervals 6 Independent ECM Connections 6 Independent Contact Closures Front Panel Digital AC Mains Voltage and Current Meter Font amp Rear Mounted XLR Connector for 12VDC Gooseneck LED Lamp Oty 1 Atlas Power AP GNL18 LED Gooseneck Lamp Included External Switch Sequence Trigger Activation External DCV Sequence Trigger Activation 5 24VDC Abnormal AC Line Voltage Indicator for Voltages Between 101VAC 107VAC or 128VAC 132VAC Extreme Voltage Shutdown EVS Below 101VAC or Above 132VAC Line ECM MODULES KEY FEATURES Manual Auto On Off switch ncoming AC present LED Active LED AC Fault LED Clamping Spike amp Surge Suppression EVS Circuitry AC Mains Voltage amp Current monitoring Voltage only for ETA ECM20 EMI amp RFI Filtering Not in ETA ECM20 APPLICATIONS The ETA ECS6RM was designed to be flexible with features that allow it to be used in a variety of applications The sequenced outputs allow the turning of equipment On and Off in a particular order to eliminate an in rush of current and audible pops that often occur with non sequenced power strips It also can be used solely for protection against voltage surges If fuzzy video or frequent static pops occur the AC power conditioning will eliminate or reduce those inconveniences The following are just a few examples of applications in which the ETA ECS6RM can be used Restaurants Houses of Worship
24. er ETA Systems Tech Support can be reached at 1 800 321 6699 Visit our web site at www ETAsys com to see other ETA Systems products ETA SYSTEMS Leading by Design 2009 ETA Systems All rights reserved ETA003564 RevB 8 09 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 241 ETAsys com Specifications are subject to change without notice
25. f and monitoring are required the ETA 15SH 15A and the ETA 20SH 20A can be a perfect fit All ECM modules offer different and unique packaging designs and mounting options to assure they meet job requirements Features of the ECM modules vary allowing the customer to choose what is best for their installation but all ECM modules feature AC spike suppression AC Spikes or Transients are commonly caused by utility power plant grid switchovers The amount of energy that can be injected into the power system can be immense with voltages reaching 6kV or amperage peaks of 3000A These spikes are very fast and usually only last for a very short period of time To protect against this potential problem incoming AC Mains have special suppression circuitry to eliminate the unwanted energy This circuitry is very fast and can suppress unwanted energy within a nanosecond while sustaining the suppression for up to 2 milliseconds thus ensuring virtually trouble free protection High and Low AC Main line voltages are another major contributor to equipment failures The ECM modules support EVS circuitry which enables the module to be shut Off during Low and High AC Line conditions The ETA ECM20M ETA 15SH and ETA 20SH also feature noise filtering for unwanted Radio Frequency Interference RFI that is commonly introduced into the AC lines by nearby radio transmitters or wireless products EMI filters are incorporated to reduce noise from Electromagnetic Interfer
26. ght Socket The XLR socket is used for the optional 12VDC AP GNL18 LED Gooseneck Lamp One lamp from ETA Systems sister company Atlas Power is included Additional lamps are available through ETA Note This is not an audio connection 6 Light On Off Switch This switch turns On or Off the voltage to the XLR lamp socket 7 System Control In Out Ports These ports are used when you need to daisy chain more than one ETA ECS6RM together Up to three units can be connected in series REMOTE Connection is via a RJ45 connector A common Ethernet cable can be used CONTROL Note This is not an IP Ethernet port and is only used for ETA ECS6RM connectivity KEY PAD IN between units Distance between units can be several feet apart Start with the Master Unit by connecting to the OUT connector port and then into the first Slave units IN connector port SYSTEM CONTROL OUT Remote Control Key Pad Port This port is for connection with the ECS KSW6 AE i OTE AFTER CHANGING SWITCH SETTINGS Remote Key Switch System Status Plate This is an optional accessory item that HE UNIT S POWER MUST BE RESET allows you activate lock out and monitor the AC Mains system from up to 1000ft away See Remote ECS KSW6 for details Connection is via a RJ45 connector A common Ethernet cable can be used Note This is not an IP Ethernet port and is only used for connectivity between ETA ECS6RM and the ECS KSW6 units Wiring of this connector is th
27. hen a unit is selected as a Slave Unit the Front Panel Slave Mode LED will illuminate Also follow the System Control Port section below for unit daisy chain connection Note After changing a setting the unit power must be 1 Sec 3 SEC 6 SEC reset for the changed settings to take effect a Delay Time Switches The ETA ECS6RM has three timing settings between each sequence 1 Second 3 Seconds and 6 Seconds Follow the chart for the settings for Switches C amp D When daisy chaining multiple units together each unit s settings only relate to that individual unit For example you can set Unit One for 3 Seconds Unit Two for 1 Second and Unit Three for 6 Seconds or all can have the same setting Note After changing a setting the unit power must be reset for the changed settings to take effect Auto EVS Bypass Switch The Extreme Voltage Shutdown EVS has two settings to meet your install requirements The selection of the settings are via switches E or F The selection affects all six channels When Enabled the EVS circuit will trigger an ECM shutdown when an extreme voltage condition occurs and will auto reset when the voltage has stabilized When Disabled the EVS circuitry will trigger a shutdown during and extreme voltage condition and will not turn back on unless the unit is sequenced See EVS feature definition for details Note After changing a setting the unit power must be reset for the changed setting to take effect 5 Li
28. ill report back to the ETA ECS6RM causing the Channel Activation LED to flash Red indicating an error has occurred Note The LED will continue to flash until the voltage has stabilized at the ECM module and ETA ECS6RM is reset To reset the ETA ECS6RM restart the sequencing Note It is also possible to have Channels flashing Red while others are operational with a steady Green LED This is because an ETA 15SH or ETA 20SH can be placed on a different AC leg up to 1000 away Not all ECM modules may see the same error in AC Mains voltage thus allowing some ECM modules to remain operational 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 27e ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design TRIGGER MODE MODE xc cry 8 eet ETA SYSTEM ACTIVATION ETA ECS6RM REPRESENTS CHANNEL SELECTED Power Condaioner 6 Sequencer Channel Selection Switches These push button switches allow the selection of the channel to be viewed at the Voltage and Current Meter Channel Selected LEDs There are six Channels in the ETA ECS6RM and only one Channel Voltage or Current can be viewed at a time The Channel selected and being viewed is indicated by the illuminated LEDs AC Mains Voltage and Current Meter There is only one Volt and Current Meter There are up to six Channels of viewing
29. ities of any device to absorb without some degree of damage In the rare instance that this occurs the clamping circuit has been damaged during the suppression The unit will need to be repaired or replaced It is important to have all equipment that was connected to that AC Mains Line be inspected for proper operation Note The unit will still operate but no AC Spike or Suppression protection will be available Issue 3 ECM module is set External Trigger the Incoming AC LED is Illuminated but the Active LED is not Illuminated Possible Cause 1 Possible Cause 2 Possible Cause 3 External DCV from the ETA ECS6RM is not connected across the and G terminals of the ECM module External DCV voltage polarity is not correct across the and G terminals External DCV voltage is too low to activate the trigger circuit Must be a minimum of 5VDC to activate the ECM module Possible short in the wiring system Issue 4 ECM Active LED is not illuminated but the Incoming LED is The Abnormal LED on the ETA ECS6RM voltage display is flashing OL and the ETA ECS6RM Channel that is activating the ECM module Green Status LED is Flashing Possible Cause Action Needed The AC Mains Voltage was between 101VAC and 107VAC or 127VAC and 132VAC activating the EVS shutdown The ETA ECS6RM must be re sequenced to reset the circuit Measure the AC mains before the ECM module If the voltage is between 117VAC and 123VAC
30. ivation switch is defeated ACTIVATION e Slave Mode When the Slave Mode LED is Illuminated it indicates that there are more than one ETA ECS6RM connected to the trigger sequencing Up to three ETA ECS6RM units can be connected in series Refer to Rear Panel System Control for more details 3 Channel Activation Status LEDs There are six Bi Color LEDs that represent Channels 1 thru 6 of the ETA ECS6RM These LEDs indicate when there is AC CHANNEL ACTIVATION STATUS voltage present or if there is an error within the AC Mains System Red Standby Green ON Flash a c r e Red Standby If a Channel on an ETA ECM20 ETA ECM20M ETA 15SH 4 or ETA 20SH module is connected to the ETA ECS6RM a Red LED will illuminate indicating that Channel is active and in Standby mode If there SELECTED CHANNEL are Channels of the ETA ECS6RM with no ECM modules connected NO 4 be LED for that Channel will illuminate indicating NO CONNECTION nC has been established Note If the Channel is selected for monitoring has no CHANNEL MONITORING SELECTION CONNECTION the LCD display will read nC e Green ON When the ETA ECS6RM has been activated and sequencing is completed the LED for channels that have an ECM module connected will turn from Red Standby to Green to indicate the ECM module is activated and operational e Red Flashing If a fault in voltage occurs the ECM 6RM will shut the ECM module off and w
31. ller The specific job AC power requirements and power distribution layout will dictate how the ETA ECM20M Modules are wired into the Raceway Each ECM Module can be wired as a single 20A run or in a parallel configuration as illustrated below Each ECM module has dual 3 position Screw terminal blocks that are in parallel and are clearly labeled as follows ECM Module PCB Labeling For incoming AC Mains Note The above figure shows the ECM wiring configuration of one 20A AC main line coming into an ETA ECM20M then paralleling with an ETA ECM20 type module Note It appears that the wiring is in series but the ECM Module In Out terminals are in parallel on the PCB Example 1 ECM wiring configuration showing one 20A AC main line coming into an ETA ECM20M then paralleling with 5 ETA ECM20 type modules Note It appears that the wiring is in series but the ECM Module In Out terminals are in parallel on the PCB Example 2 ECM wiring configuration showing two 20A AC main lines coming into the raceway for a total of 40A available The 20A legs are separated by feeding a 20A leg to two different ETA ECM20M Modules The leg is then paralleled with two ETA ECM20 type modules Note It appears that the wiring is in series but the ECM Module In Out terminals are in parallel on the PCB AC main in 20A AC main in 20A Example 3 ECM wiring configuration showing one 20A AC main line coming into 6 ETA ECM20M type modules N
32. lso activate an ECM by applying a contact to short terminals and D together Note the EVS and Voltage monitoring will be disabled using either of these methods ECM MODEL FEATURES EMI RFI Filters ECM noise filtering for unwanted Radio Frequency Interference RFI that are commonly introduced into the AC lines by nearby radio transmitters or wireless products EMI filters are incorporated to reduce noise from Electromagnetic Interference EMI from such items as electric motors or switching power supplies The benefit of these filters can be seen on video products or audibly by reducing static pops and external signal interference AC Spike Protection ECM modules feature AC spike suppression AC Spikes or Transients are commonly caused by utility power plant grid switchovers The amount of energy that can be injected into the power system can be immense with voltages reaching 6kV or amperage peaks of 3000A These spikes are very fast and usually only last for a very short period of time To protect against this potential problem incoming AC Mains have special suppression circuitry to eliminate the unwanted energy This circuitry is very fast and can suppress unwanted energy within a nanosecond while sustaining the suppression up to 2 milliseconds thus ensuring virtually trouble free protection AC Surge Protection High line can also be known as surges Surges usually are a slower steady state rise in voltages ranging from 128VAC
33. ng The ETA ECM20 and ETA ECM20M require an electrical housing The ECM RACEWY holds up to 6 ECM modules There are standard 34 and 1 electrical knockouts on the bottom of the raceway to support standard electrical mounting hardware Since the Raceway can house 6 ECM modules there can be 6 separate 20A AC legs coming into the Raceway for a total of 120A of power distribution or it could be as simple as one 20A leg Note All electrical wiring must be done by a certified electrician All cover plates must be secured tightly There shall be no open slots Blank cover plates are available Top and bottom mounting tabs are incorporated to mount inside an Atlas Rack All rack mount rails are designed to be breakaway if they are not needed Simply bend the tab back and forth until the tab breaks away Be careful of sharp edges ECM 3BP Module Cover Plate The ECM RACEWY6 can hold up to 6 ETA ECM20 ETA ECM20M Modules however it is ok to use less than 6 modules The open slot on the ECM RACEWY6 can be covered up using an ECM Module Blank Plate cover Two of these are included with the ECM RACEWY6 If not needed discard them If additional Blank Plates are required they can be purchased in packages of three ECM ACIN Wire Kit ETA offers a wire kit of stranded 12 guage UL wire for wiring the ETA ECM20 Modules together plus additional length for wiring the incoming AC to an AC Mains panel 140 of each color of Green White and Black are included Note
34. ote It appears that the wiring is in series but the ECM Module In Out terminals are in parallel on the PCB AC Main in 20A 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 18 ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer N SYSTEMS N Leading by Design TROUBLESHOOTING Note All troubleshooting should be done by a certified electrician Issue 1 ECM Module Incoming AC LED is not illuminated Possible Cause 1 Action Needed Possible Cause 2 Action Needed Incoming AC mains circuit breaker has tripped due to excessive load Check the AC outlet that the ETA ECS6RM is plugged into for proper voltage If no voltage is present check to see if the AC outlet is on a GFI check to see if it was tripped If it has not been tripped trace the AC Mains outlet back to the electrical panel and check the AC Mains breaker to see if it is tripped AC mains power is OK 120V internal 15A ETA 15SH and 20A ETA ECM20 ETA ECM20M ETA 20SH Slow Blow fuse is blown Open ECM unit and replace the fuse with a Slow Blow type Issue 2 ECM module AC Fault LED is Illuminated on the ECM Possible Cause Action Needed Although the Clamping Suppression circuit virtually assures protection from most transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabil
35. pike Suppressor q P Engineered in the U S A Made in China ETA SYSTEMS 1601 Jack McKay Bhd Ennis TX 75119 U S A www otasye com a ECS KSW6 The ETA ECS6 can be remotely activated with each channel being monitored by using the Atlas Power ECS KSW6 control panel available through ETA Systems This panel can be placed several hundred feet away from the ETA ECS6 controller A Keyed On Off switch is provided for security There are six Bi Color LEDs on the ECS KSW6 panel One LED for each of the six sequenced channels of the ETA ECS6 These LEDs mimic the Channel Activation LEDs that are on the front of the ETA ECS6 panel Please refer to that section for complete details Wiring the ECS KSW6 panel requires a RJ45 connector and 8 conductors Note This is not an IP Ethernet port and is only used for connectivity between ETA ECS6 and the ECS KSWS units Wiring of this connector is the same as an Ethernet cable Do not mis wire the connector or damage may occur 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 15 ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N ETA ECS6RM WIRING CONFIGURATION Example 1 ETA ECS6RM wired to six ETA ECM20 or ETA ECM20M Modules using an ECS KSW6 for remote activation
36. required and the channel must be selected to monitor The Channel you are viewing will have a single LED illuminated Refer to the Channel Select LED The Voltmeter has a 296 accuracy tolerance and will indicate the Voltage present at an ECM module For the Current reading to function an ETA ECM20M ETA 15SH or an ETA 20SH module must be connected Also a minimum of 500mA of current draw must be at the ECM module for the ETA ECS6RM to read Less than that the display will read nA When using the ETA ECM20 module the Current display will read nA because it has no current sensing circuitry Note When first applying power to the ETA ECS6RM and no ECM modules are connected the Voltage display will display nC because it has no external voltage to read VOLTAGE CURRENT REPRESENTS CHANNEL SELECTED Light Socket The XLR socket is used for the optional 12VDC AP GNL18 LED Gooseneck Lamp One lamp from ETA Systems sister company Atlas Power is included Additional lamps are available through ETA Note This is not an audio connection Light On Off Switch This switch turns On or Off the voltage to the XLR lamp socket Adjustable and Removable Rack Mount Ears The depth of the ETA ECS6RM can be adjusted to meet the requirements of the rack Loosen the corresponding screws set depth and retighten screws The rack ears can also be removed 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821
37. signals are of low voltage and current DO NOT MISWIRE or damage may occur Requires a minimum of 5 24VDC to activate the module with 5mA of current Note The DCV can be supplied from any source The EVS protection requires the ETA ECS6RM for operation Circuit Ground must be of the same circuit as the DCV source AC Voltage Status Signal this signal reports back to the ETA ECS6RM the Incoming AC Mains Voltage to the ECM module AC Current Status Signal this signal reports back to the ETA ECS6RM the AC Mains Current draw at the ECM module U gt lt Fault Status Signal reports to the ETA ECS6RM fault conditions of an ECM module 2 External Trigger Manual On Switch ETA ECM20M ETA ECM20 ETA 20SH and ETA 15SH have a manual override switch allowing them to be used for a local Power Conditioner and Surge Suppressor To be remotely monitored and activated the switch must be in the External Trigger position 3 Incoming AC LED This LED will illuminate Red when the ECM has incoming AC power present at the module This LED must be On to operate Note If this LED is not illuminating check the following 1 The unit is plugged in 2 The AC Mains Breaker feeding the AC leg to the ECM module is Off 3 The internal fuse has been damaged This should only be inspected by an authorized technician 4 Active LED This LED will illuminate Green when the ECM module has sensed the proper DCV to trigger activate the power on circui
38. support the current read out circuitry Probable Cause 2 The A terminal wire is not connected Probable Cause 3 The correct module type is connected but there is not enough current being drawn to register Note It takes 7A for current draw from the ECM module for a reading Issue 11 No LEDs are illuminated on the ETA ECS6RM and the Voltage display reads nC Probable Cause No ECM modules are connected to the ETA ECS6RM or the ECM modules have no AC power to them 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 20 ETAsys com Specifications are subject to change without notice ETA ECS6RM SPECIFICATIONS General Type Sequencer Sections Relay Sections Sequence Timing Unit Link Power Supply Power Consumption RoHS Compliant Dimensions Weight Front Panel Lights LED Light Switch Activation Switch AC Mains Voltmeter AC Mains Current Meter Indicators Channel Selection Channel Selected Indicator Activation Indicators Rear Panel Sequenced Activation Status Signal Port Remote Activation Trigger Sequenced Relay Contacts Sequence Time Selection System Master Slave Assignment System Control Loop In Out EVS Bypass LED Light Socket LED Light Switch DC Input Jack Electrical Control Sequencer SYSTEMS N Leading by Design ETA ECS6RM Power Sequencer Controller 6 6 Unit Settings of 1 3 or 6 Seconds 3 Ex
39. t Note If connected to the ETA ECS6RM and the EVS circuit is activated this LED will not be on The Channel Status LED on the ETA ECS6RM will flash indicating a problem and will not turn the ECM module on until the AC Mains voltage is stable 5 AC Fault LED If damage to the Spike Suppression circuit occurred this LED will illuminate RED The module may still operate but may not be protecting the items plugged into the AC outlets This LED will not turn Off until repaired Have the ECM module inspected by a qualified technician 6 AC Mains Outlet Two 120V AC 15A outlets 7 AC Mains Power Cord 9 3m 120V 15A 8 Mounting Bracket There are two adjustable mounting brackets incorporated There are three screws per side for bracket placement Each bracket has a slide slot to allow mounting height adjustment 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 12 ETAsys com Specifications are subject to change without notice ETA ECSGRM ETA Electrical Control Sequencer N SYSTEMS N Leading by Design ETA ECS6RM ACCESSORY ITEMS AP GNL18 LED Gooseneck LAMP The Atlas Power AP GNL18 is an optional LED Gooseneck Lamp and works with any of the ETA Systems 12VDC XLR base mount connectors The length of the gooseneck is 16 ETA 15SH Standalone 15A Power Conditioner and AC Spike Suppressor This Electrical Control Module ECM is a 15A Power Conditioner and AC Spik
40. t relay contacts The activation of the contacts work in parallel of the corresponding ECM triggered outputs Activation can be done via the Front panel momentary switch RMT V input 5 24VDC External switch or via the optional Remote ECS KSW6 key switch The ECS KSW6 can be placed up to 1000 ft away from the ETA ECS6RM and will also indicate if an ECM is activated or if a fault condition has occurred to one or all six channels To light your rack the ETA ECS6RM has incorporated both front and rear XLR style sockets for the 16 gooseneck LED lamp One Atlas Power AP GNL18 lamp is included and a second lamp can be purchased separately from ETA Systems LED lamps are far superior in longevity along with heat reduction when compared to traditional incandescent lamps and the XLR base mounts are also superior to the commonly used BNC type base The ECM modules have been designed to be flexible to meet a variety of AC power management requirements The mating of the ETA ECS6RM to the ECM modules can be accomplished using any 5 conductor cable and can be placed up to 1000 ft away from each other Each ECM module has an input DC voltage trigger of 5VDC plus three low voltage data port connections for AC Mains monitoring If AC outlets are required to be placed within the same rack as the ETA ECS6RM the ECM RACEWY6 raceway can house up to six ETA ECM20 or ETA ECM20M modules and six independent 20A AC 120V lines For remote locations where single outlet turn On Of
41. ternal Wide Rage 100V 240VAC UL Approval BW Yes H 1 75 x W 19 x D 10 7 lbs 3 1kg XLR Socket to Provide 12VDC for Optional 16 Atlas Power Gooseneck Lamp AP GNL18 Qty 1 Included Two Position On Off Momentary Three Digits Digital Three Digits Digital System On External Trigger Mode Slave Mode Momentary Switches Single LED Per Channel Total Six LEDs Six Bi Color LEDs One For Each Channel Six Channels Interconnect port Trigger Out and Status Signal Return Euro Phoenix Type Connector 5 24VDC Continuous 10 mA Switch Contacts Euro Phoenix type Connector Six Channels Single Relay Contact SPST Each Channel Euro Phoenix Type Connector Setting 1 3 6 Seconds Dip Switch Select Master Slave Unit 1 Slave Unit 2 Dip Switch Select One IN Control Port One Loop OUT Control Port for Slave or Master Three Units Can Be Linked Connector RJ45 Not an Ethernet Connection Extreme Voltage Shut Off Enable Disable Dip Switch Assign XLR Socket to Provide 12VDC for Optional 16 Gooseneck Lamp AP GNL18 Two Position On Off External Power Supply Wide Range 100V 240VAC 20V DCV UL Listed 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 21 ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N NOTES 1601 Jack McKay Blvd Ennis Texas 75119 U S
42. you may proceed to reset the ETA ECS6RM by restarting the start up sequence Note It is important to have all equipment that was connected to that AC Mains Line inspected for proper operation If the problem persists contact your local power company for the cause of unstable AC line conditions 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 19 ETAsys com Specifications are subject to change without notice ETA ETA ECSGRM SYSTEMS Electrical Control Sequencer Leading by Design N Issue 5 ETA ECS6RM Channel Activation Status LED is Flashing Green and AC Power and Active LED at the ECM Module is Illuminated Possible Cause The AC Mains Voltage at the ECM Module reached between 127VAC 132VAC or the voltage dropped between 101VAC 107VAC Action Needed The ETA ECS6RM must be re sequenced to turn off the LED Measure the AC Mains before the ECM Module If the voltage is between 117VAC and 123VAC you may proceed to reset the ETA ECS6 by restarting the start up sequence Note It is important to have all equipment that was connected to that AC Mains Line be inspected for proper operation If the problem persists contact your local power company for the cause of unstable AC line conditions Issue 6 No Voltage Reading at the ETA ECS6RM Possible Cause 1 Check Issues 1 4 first Possible Cause 2 Proper Channel is not selected for viewing Possible Cause 3 Channel