Emerson IS-WEB485ADPT Network Card User Manual

image

Contents

1. Support tab EMERSON monitor control configure support Agent Information Support Data Room UPS hom Value Bldg 2 Floor 4 _ Supports Server02 System Name Data Room UPS 192 168 0 125 Location Bldg 2 Floor 4 Device Status Description Supports Server02 Load Protected Contact Network Svcs x100 No Alarms Present Manufacturer iebert Corporation Model Part Number Agent Model IntelliSlot Web Card Agent Part Number locwescaro VU and Firmware Version S um mary Support Agent App Firmware Version 2 300 0 li Summary Ag mz a Er Sie 2 300 0_035191 SNMP Capabilities Agent Boot Firmware Version 2 300 0 Agent Boot Firmware Label OCWEBCARD_HID3_2 300 0_034380 arameters Agent Hardware ID 3 A 3 3 Download the Firmware Upgrade File to the Computer NOTE Turn off the power management on your PC or laptop before beginning the update to ensure that communication will not be disrupted during the process To download the upgrade file 1 Open a Web browser such as Internet Explorer 5 5 or newer 2 Navigate to Liebert s Web site www liebert com downloads 3 Choose the firmware upgrade for your card from the selections on the Web page see A 3 2 Determine the Liebert IntelliSlot Card Type and Firmware Version 4 Click on the link to download the file 5 Save the file to your computer s hard drive Be sure to make a note of the location where the file is saved
2. 1 System Information ion i 2 IP N k i Check the new firmware version if you wish see A 3 2 Determine 3 si er An RAN 4 5 Messaging i the Liebert IntelliSlot Card Type and Firmware Version Factory Settings Firmware Updates Quit and abort changes Exit and save xQ Please select a key gt 5 A12 Updating the Firmware Xmodem Serial Method Notes A13 Updating the Firmware Xmodem Serial Method A14 Ensuring The High Availability Of Mission Critical Data And Applications Emerson Network Power the global leader in enabling business critical Technical Support Service continuity ensures network resiliency and adaptability through _ Web Site a family of technologies including Liebert power and cooling www liebert com Monitoring technologies that protect and support business critical systems Liebert solutions employ an adaptive architecture that responds 800 222 5877 Liebert monitoring emerson com to changes in criticality density and capacity Enterprises benefit Outside the US 614 841 6755 from greater IT system availability operational flexibility and Single Phase UPS reduced capital equipment and operating costs 800 222 5877 upstech emersonnetworkpower com Outside the US 614 841 6755 Three Phase UPS 800 543 2378 powertech emersonnetworkpower com Environmental Systems 800 543 2778 Outside the United States 614 888 0246 Locations United States 1050 D
3. Issued to Allegro Root CA Issued by Allegro Root CA Valid from 5 13 2002 to 5 13 2032 Install Certificate io Issuer Statement The Certificate Import Wizard opens Click Next Certificate Import Wizard x Welcome to the Certificate Import Wizard This wizard helps you copy certificates certificate trust lists and certificate revocation lists from your disk to a certificate store Certificate Import Wizard x Certificate Store Certificate stores are system areas where certificates are kept Windows can automatically select a certificate store or you can specify a location for A certificate which is issued by a certification authority is Automatically m aI a confirmation of your identity and contains information Automatically select the certificate store based on the type of certificate used to protect data or to establish secure network select Place all certificates in the following store Gertificate store wi connections A certificate store is the system area where certificates are kept To continue dick Next e Click on Automatically select the certificate store based on the type of certificate then click Next Certificate Import Wizard xj Completing the Certificate Import Wizard You have successfully completed the Certificate Import wizard You have specified the following settings Certificate Store Selected Automat
4. En Gp Terminal Emulation Serial or TCP IP Connection Telnet To change any parameter 1 Choose IP Network Settings from the Main Menu then Management Protocol 2 Select an option to change then use the following guide to make changes Table 11 Management protocol ranges Description amp Telnet Menus SNMP Agent Enable or disable SNMP for remote management Set up access privileges configure the Web card to send traps described in the next section SNMP Communications Menu SNMP Communications Menu Authentication Traps no RFC 1628 UPS MIB enabled Traps enabled Liebert Global Products MIB enabled Condition Traps enabled System Notify Tra enabled Heartbeat Trap Interval Display Modify Communities Display Modify Trap Communities Support Information SNMP For details on viewing support information Communications See 9 2 Events and Parameters 1 2 3 4 5 6 T 8 9 A lt ESC gt Cancel menu level please select a key gt 1 13 Ey Web Interface To access Management Protocol settings through the Web interface Network Settings e Click on the Configure tab then Management Protocol in the left panel and finally Edit in the right panel After making changes click Save Configure tab Management Protocol Click on Edit to enable any options _ EMERSON Network Power Agent Information SNMP_Test SNMP_Test3 SNMP_Tes
5. A4 Updating the Firmware HTTP Web Method A 3 4 Choose a Method to Install the Firmware Upgrade A 4 To install the firmware upgrade choose one of these three methods and refer to the associated step by step directions HTTP Web see A 4 Updating the Firmware HTTP Web Method TFTP see A 5 Updating the Firmware TFTP HyperTerminal Telnet Web Method Xmodem Serial see A 6 Updating the Firmware Xmodem Serial Method UPDATING THE FIRMWARE HTTP WEB METHOD Follow these steps to install the firmware upgrade using the HTTP Web method This method is available through the Web interface only and requires an Ethernet connection to the Web card A 4 1 Install the Firmware Upgrade NOTE Turn off the power management on your PC or laptop before beginning the update to ensure that communication will not be disrupted during the process To update the Liebert IntelliSlot card firmware using the HTTP Web method 1 Open aconnection to the Liebert IntelliSlot card Gf needed see instructions in A 2 4 Open the Web Interface 2 Click on the Configure tab then click on Web under Firmware Update in the left panel The Connect To box opens for you to enter the username and password 3 Enter the Administrator username and password both case sensitive a User Name default is Liebert b Password default is Liebert 4 Click OK The Web HTTP Firmware Update window ope
6. Connect one end of a DB 9 null modem or file transfer cable to the Web card s serial port and the other to the computer s serial port The correct cable will have at a minimum Pins 2 and 3 crossed at the ends as shown in Figure A1 Null connection DTE Device DTE Device Receive Rx Pin 2 e n c Receive Rx Pin 2 Transmit Tx Pin 3 Transmit Tx Pin 3 Firmware Updates Menu Open a connection to the Liebert IntelliSlot card if Cl needed see instructions in A 2 1 Open the Terminal 2 pd Emulation Interface Serial Connection ETA 1rmware paate ep Choose Firmware Updates from the Main Menu Choose XMODEM Update from the Firmware Updates menu seen at right and enter y yes to confirm your T alle au ie choice x Exit Cancel Please select a key gt Current Communications Rate is 9600 bps Choose Xmodem1K from the Select Firmware Update Protocol as shown at right Change the Baud Rate to 115200 6 7 8 9 10 11 115200 bps Choose 1152300 bps from the menu shown below left From the HyperTerminal menu click on Call then choose Disconnect this will not close the HyperTerminal connection to the card In the HyperTerminal menu bar click on File then choose Properties Click on the Connect To tab and click the Configure button This opens Port Settings tab in the COM1 Properties window as shown below right Choose 115200 from the Bits Per Second drop down list and
7. Monitoring For Business Critical Continuity Liebert IntelliSlot Web Cards Installation Manual Liebert IntelliSlot Web Card Liebert IntelliSlot Web Card LB Liebert IntelliSlot Web Card LBDS Liebert IntelliSlot Web 485 Card ADPT x o Sed Seva a pees ES T n E 4 EMERSON Network Power TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS 4 Jk kk kk kk kk kk kk kk kk kk kk kk kk kk kk oth Ad 1 1 0 INTRODUCTION marras rara un Ap lk ln ween ki cir amen eae meee ico qe 2 1 1 Compatibility With Liebert Equipment 2 1 2 NV CO DUDDOL gt Saa he na IE ae Dk es Chee beads nk dn haa iv d ae naa 3 1 3 Password VOLCCUION ss xa yl ES eS ae Ae Mu A eb ee ee a A 3 1 4 SNMP UPO bus dead dansa go dee Dec a ater MR os Sc esl gO ak eds ea A 3 1 3 Liebert Nform PIE Ol Gc cay aie SONA Qun a ess ie Be ODA Ke n a So ee eee oat 3 1 6 Liebert MultiLink UO a ee e e e en Mer r a a AIAIARTRrXre IE 3 1 7 Liebert SiteScan Web With Modbus Support IS WEB485ADPT only 3 2 0 INSTALLATION 24 4 u qr varia abr T ee dare eee Oo WG reared 4 2 1 Install a Liebert IntelliSlot Web Card Non Adapter Version 000000 4 2 2 Install a Liebert IntelliSlot Web 485 Card With Adapter 00 00 00 cee eee 5 3 0 CONFIGURATION OVERVIEW kk kk kk kk kk kk kk lk kk kk kk a kk kk kk kk kk kk kk kk kk kk kk 6 3 1 Guide to ConmeuralOns cS san n Ka we die ae
8. Continue to this website not recommended Continue to this website More information e Click on Continue to this website not recommended to open a connection to the Web card Dl xi Z fe CJ 7 ERE ee ee WE certfcate Emer i ae y Untrusted Certificate File Edit View Favorites Tools ele Y The security certificate presented by this we we Emerso work Power InteliSlot Web Card gt O website was not issued by a trusted certificate authority fool you or intercept ar y data you send to EM ERSON b Lieb the server Google This problem may indicate an attempt to Certificate Error monitor control configure support A ent odos Summary Updated September 3 2007 04 01 04PM oe that you close this Data Room UPS Bldg 2 Floor 4 About certificate errors Supports Server02 192 168 0 125 View certificates Device Status Load Protected No Alarms Present View INPUT OUTPUT Certificates Monitor Categories ji Vois 1166 Y iS Volts 1201 V f j e Click the Certificate Error box next to the address bar shown above left In the window that pops up shown above right click the View Certificates link This opens the Certificate window eon Co Certificate pa Certificate Information Path tab of Liebert Monitoring Group 192 168 0 125 is certificate cannot be verified up to a trusted certification authority
9. Issued to 192 168 0 125 Issued by Liebert Monitoring Group View Certificate Valid from 7 2 2007 to 3 27 2036 Certificate status This CA Root certificate is not trusted because it is not in the Trusted Root View Certification Authorities store C e rtifi c at e Issuer Statement In the Certificate window above left click the Certificate Path tab In the Certificate Path tab above right click on Allegro Root CA then on View Certificate 22 Network Settings In the Certificate window click the Install Certificate button as shown below 21x General Details Certification Path Certificate Information This certificate is intended for the following purpose s Ensures the identity of a remote computer Issued to Allegro Root CA Issued by Allegro Root CA Valid from 5 13 2002 to 5 13 2032 Install Certificate io Issuer Statement The Certificate Import Wizard opens Click Next Certificate Import Wizard x Welcome to the Certificate Import Wizard This wizard helps you copy certificates certificate trust lists and certificate revocation lists from your disk to a certificate store Certificate Import Wizard x Certificate Store Certificate stores are system areas where certificates are kept Windows can automatically select a certificate store or you can specify a location for A certificate which is issued by a certification au
10. Network Power monitor control support Agent Information ee ee Data Room UPS Bldg 2 Floor 4 Command Description Supports Server02 Abort Commands Halt execution of pending commands 192 168 0 125 Alarm Silence Temporarily silence the audible alarm Device Status Output Turn the output of the UPS On or Off and transfer either the bypass or inverter to the output Load Protected Statistics Reset statistics Mo Marne Prosent Tests Initiate diagnostic tests Control Operations Control Operations P P E Summary Click to v ew n Abort Commands Alarm Silence right panel Za Tests e Control Operations categories appear at bottom left organized with folder icons and showing the available Control functions Clicking on a category changes the view in the right panel The example above shows the summary page The following guide is a partial list of Control operations these vary by the type of Liebert unit Table 23 Control operations parameters functions vary by Liebert unit Abort Commands Prevent any pending commands from being completed Alarm Silence Alarms Temporarily silence an audible alarm that is active Reset or acknowledge alarms Statistics Reset satisios for example battery or power siatstes TT Setpoints Change setpoints for tne Lieben unt To perform an operation click on a Control Operations category at left then click on the appropri ate button
11. Subnet Mask 13 Network Settings 5 2 Domain Name Server DNS Settings The Domain Name Server settings menu configures the servers the Web card will use for hostname resolution When configured host addresses for SNMP Network Time and Email SMS can be speci fied in either full Domain Name format or in host only format provided that the appropriate Domain Name Suffix is used The DNS menu is used to set parameters for network access to the Web card Consult your network administrator for these settings EM LS Terminal Emulation Serial or TCP IP Connection Telnet To change any parameter 1 Choose IP Network Settings from the Main Menu then Domain Name Server DNS Settings 2 Select an option to change for example DNS Mode then enter settings according to the following guide Table 10 Domain Name Server settings Description amp Valid Settings Obtain DNS server addresses automatically or use specified addresses DNS Mode Note Automatic assignment option is available only if a DHCP server is used to assign IP information to the Web Card Primarv DNS Primary IP address of the name server for network ry Four numbers 0 255 separated by periods e g 192 168 0 1 DNS Resolve Interval Interval to resolve DNS addresses from a network name to an IP address Domain Name Suffix Neer used for assembling a fully qualified domain name when a host only name Checks whether the Web card will resolve a hostna
12. v TET Liebert IntelliSlot Web 485 Card ra suce lt vl Pe Liebert IntelliSlot Web cards support both 10Mbit and 100Mbit communication speeds and either half or full duplex NOTE See online demonstrations of Web cards installed in Liebert equipment at http demos liebert com 1 2 1 3 1 4 1 5 1 6 1 7 Introduction Web Support The Liebert IntelliSlot Web card delivers Web management and control to Liebert equipment All authorized users on your network will be able to view status information Password Protection Control and configuration capabilities are protected by a username and password combination Optionally status information can be password protected The default username is Liebert and the default password is also Liebert You can change the password using the terminal emulation Telnet or Web interface See 5 7 Change Username Password for details NOTE Change the username and password today to prevent unauthorized access SNMP Support The Liebert IntelliSlot Web card enables SNMP management of Liebert equipment To integrate the card into your SNMP implementation compile the Liebert Global Products MIB on your network management station NMS The Liebert Global Products MIB is included in this package on CD ROM and supports both Windows and Unix file formats Liebert Nform Support Utilizing the SNMP and Web technologies built into each of the Lieb
13. Card family delivers enhanced communications and control to Liebert AC Power and Precision Cooling systems Liebert IntelliSlot Web cards bring SNMP Telnet and Web management capability to many models of Liebert power and cooling equipment The cards employ an Ethernet network to monitor and manage a wide range of operating parameters alarms and notifications Liebert IntelliSlot Web 485 Card With Adapter IS WEB485ADPT Liebert IntelliSlot Web card IS WEBCARD IS WEBLB and IS WEBLBDS 1 1 Compatibility With Liebert Equipment The Liebert IntelliSlot Web Card family formerly the OpenComms line includes Liebert IntelliSlot Web Card Compatible with these Liebert UPS models Liebert PowerSure PSI Liebert GXT Liebert GXT 6kVA amp Liebert GXT 10kVA Liebert GXT2U and Liebert Nfinity Liebert IntelliSlot Web Card LB Compatible with the Liebert NX and Liebert Hinet UPS models Liebert IntelliSlot Web Card LBDS Compatible with the Liebert DS Precision Cooling unit and the Liebert XDF Liebert IntelliSlot Web 485 Card ADPT Compatible with Liebert AC Power and Precision Cooling systems not equipped with a Liebert IntelliSlot port Table 1 Liebert IntelliSlot card communication protocols Communication Protocol Liebert IntelliSlot Card Part Number SNMP HTTP HTTPS Modbus E mail SMS Telnet Live nteliSlot Web coats fiswess v v v v v v Liber nteliSlot Web Cord180S ISWEBLBOS v
14. Email Customize Message SMTP Server Uninitialized Port 25 Test Email View Test Email Log File Setting up event notifications to be sent via e mail involves two steps enabling the function then specifying the parameters En Gp Terminal Emulation Serial or TCP IP Connection Telnet To activate and set up e mail messages 1 2 3 4 5 6 7 8 lt ESC gt Cancel menu level 1 Choose Messaging from the Main Menu then Email Enable Email y n gt 2 To enable the e mail feature enter y yes at the prompt Please select a key gt 3 Choose Email Configuration from the Messaging Menu then select an option and use the following guide to make changes Table 19 E mail configuration guide O Paame esposa Email From The e mail address of the sender for example support company com 64 typically the address where replies should be sent characters The e mail will be sent to this list of addresses To add an e mail address use the format a jsmith abc com Multiple addresses must be added individually Changes may be made by entering d to delete an entry or e to edit an entry NOTE To specify multiple recipients of the e mail message in the Web interface use a semicolon to separate addresses in the Email To box Email Subject The subject line of the e mail By default this is the event description e g 64 characters Email Message Recipients AlarmOnBypass but it may be custom
15. If a setpoint fails to update wait 30 seconds and refresh the page If the setpoint still fails to No Alarms Present update or does not update correctly you may have entered a value that is either invalid or out of bounds for your unit Setpoint Value Control Operations Summary Termperature Setpoint 22 0 C Alarm Setpoi nts J Setpoints Humidity Setpoint 500 RH System Temperature Proportional Band 4 0 K 37 8 3 Monitor and Control Functions Web Only Event Log The Event Log tab allows viewing events stored in the Web card s history This history is gathered only when the Web card is installed and communicating properly with the device The history is stored in descending chronological order Page 1 Item 1 contains the most recent event The list of events includes 1 The time and date of the event This is either the local time and date if the network time synchronization is working properly or the time delta from when the card was first powered on if no network time synchronization has taken place 2 The event ID This is the index number given to events since the start of the history 3 The event text Text stating the type of event and how the card reacted Event Log Controls lt lt Scroll immediately to Page 1 of the history lt Scroll left one page in the history gt Scroll right one page in the history gt gt Scroll immediately to the last page of the history Links Agent
16. OK to close the Properties window 27 In the HyperTerminal menu bar click on Call then choose Call from the drop down menu 28 Press the Enter key y Call menu com1connexion Properties Ax Connect To Settings r a com1connexion perTerminal B C amp com connexion File Edit View Call Transfer Help Change Icon Oe 53 mew COM1 Properties Ax Disconnect Terminal Window Country region Aita Change Terminal Communications Rate to Match New Rate gt i Reconnect Terminal Window Enter the area code without the long distance prefix Press Enter P1 ic F Area code Bits per second 9600 v ease select a key a L Phone number Press Enter to Start Firmware Update E Data bits 8 a Cones COM x 9600 bps Download eee exe Configure Parity None haf Firmware Checksum is correct Stop bits E A Resetting z Flow control None Please change Terminal Communications Rate to 9600 bps 7 Instructions to Change Terminal Communications Rate Disconnect Terminal Window Lx a Change Terminal Communications Rate to 9600 i Restore Default Reconnect Terminal Window Connected 0 44 47 Auto detect 115200 8 N 1 NUM C O n fi g u re Apply button 29 Choose Exit and Save from the Main Menu to reboot the card eS Main Menu When rebooting is complete the upgrade is finished
17. ORE Ee 34 T2 Liebert DS Local Node Settings for Multiple Cards o o ooooooo KK KK IK 35 8 0 MONITOR AND CONTROL FUNCTIONS WEB ONLY M4 kk kk kk kk kk kk kk kk kk kk kk kk 36 8 1 Monitoring Liebert Equipment 36 8 2 Controlling Liebert Equipment 37 8 3 Event EO a AAA Se ee ee Ae eke AA AOS E 38 9 0 SUPPORT INFORMATION 4 kk kk kk kk kk kk kk a kk a kk a a a a a a ak a kk a kk kk lk kk kk kk ka 39 9 1 View Web Card Information kk kk kK KK KK KK KK KK KK kK KK KK kK KK KK KK kk KK kk 39 9 2 MVCNUS and arame t b Ace san ha Mella ala hee hal Sd a a Ra Wl Me lana a WO dal 40 APPENDIX A FIRMWARE UPDATES 4k k kk kk kk kk a kk kk kk a kk kk kk kk kk kk kk kk kk kk kk ka A1 FIGURES Fiecare AI N ll GontteGtlOlk x sil aout Wad AWAN l bee ae od al MEYA AA k AL lava ai A10 TABLES Table 1 Liebert IntelliSlot card communication protocols 0 0 YKY KK KK KK KK KK KK KK KK 2 Table 2 Communication SOL Y Sj A 4 665 645 oon a Rat ee ORCAS ESS 40 2 A whee ewr l 6444458 4 Table 8 Communication Se UNS NAM AA A AA AT de ee Oa a ees Ae EO ee 5 Table 4 Conte tratonantertaces a 232 x l xun kh oe Q kaya it AD a n a a eh dola k A 6 Table 5 Guide to contours ton detal ta ii ES A we kan AA A de Ab RAs dh a AA a h lb fn wees 6 Table 6 Communication Sen Ne Si A E Ed a a A T Table 7 System in toria toa idente S rerai obs A A da Was 0 ASR di A ia 11 Table 8 Networ
18. Open the Telnet Interface To connect to the card using Telnet 1 To connect to the card using the Web interface 1 Preparing to Update Liebert IntelliSlot Firmware Open a Telnet connection on a computer with an Ethernet connection to the Liebert unit To do this Open a command prompt window click the Start button then Run Enter cmd and click OK In the command prompt window that opens enter telnet fol lowed by a space and the IP address of the Web card for exam ple telnet 192 168 0 125 When the message at right appears in the command prompt window press the Enter key Enter the Administrator username and password both are case sensitive a Login username default is Liebert b Password default is Liebert A 2 4 Ey Open the Web Interface Open a Web browser such as Internet Explorer MEET as Type the name of a program folder document or Internet resource and Windows will open it for you Open HE DET AN C gt telnet 192 168 0 125 RTCS v2 96 00 Telnet server Service Port Manager Active lt ESC gt Ends Session Login Liebert Password 2 Enter the IP address of the Web card in the address bar e g 192 168 0 125 3 Click on a tab at the top of the window gt Emerson Network Power IntelliSlot Web Card Windows Internet Explorer Oe X http 192 168 0 125 9 11 Google File Edit View Favorites Tools Help
19. SNMP_Test Agent Information Consolidation Time If Event Consolidation is enabled an email or Factory Defaults Limit seconds Consolidation Time Limit seconds has passe Firmware Update received Web Consolidation Event If Event Consolidation is enabled an email or Joa number of buffered events reaches the Conso Event Consolidation If checked multiple events will be sent per em TFTP Network Settings Edit Test Time SNTP C u sto m ize a ES Protocol Access IP Address M e Ss Ss a g e ZER Event Description Messaging Email Name SMS Customize Message Contac Reinitialize Location Check the items to be included in the Email or SMS message Element Email SMS Telnet Description Users 3 Web Web Link amp Port Configure Email SMS Event Consolidation Element Email SMS Event Consolidation Enable Consolidation Time Limit seconds 60 Consolidation Event Limit events 20 Message Consolidation Time Limit Message Consolidation Time Limit allows adjusting the duration the card will wait for additional events before sending a notification E mail Consolidation event limit allows adjusting the number of events each E mail will contain 33 Factory Settings 7 0 FACTORY SETTINGS Factory default values may be restored for all configuration settings This step e Replaces all user defined settings described in this manual see 3 0 Configuration Overview through 6 0 Messa
20. This value will default to the event description The subject line is customizable Fully qualified domain name or IP address of the server used for relaying SMS messages Server Web Note 1 The maximum length for this entry is 32 characters TFTP im Network Settings im DNS SMS ge im Time SNTP la Management Protocol m SNMP Note 2 If using a server name you must configure a DNS server under IP Settings Port SMTP server port Note Typically the default of 25 should be used Test Clicking on this button will send a Test SMS message after new configuration changes have taken effect Status of the SMS message will be displayed Ta Access n Traps m Messaging im Email mm SMS SMS From m Customize Message m Reinitialize in Telnet Ta Users mm Web SMS To separate addresses with semicolons Event Subject Custom SMTP Server Port 31 Messaging 6 3 Customize Messages Email SMS Customize Message Menu Both e mail and SMS text messages may be custom 1 IP Address enabled i i 2 Event enabled ized to include items such as the IP address or host an pate Tine disab ed name event name and a link to the Web card in the 4 Name enabled 5 Contact enabled body of the message 6 Location enabled T AA disabled i i a 8 we ink Port disabled ES O Terminal Emulation Serial or TCP IP Connec web o n ont ion tanan Tod tion telnet A Consolidatio
21. Web interface Configuration Overview Configure tab O Emerson Network Power IntelliSlot Web Card Windows Inter et Explorer 1 Open a Web browser such as Internet Explorer then enter Go E res 165 0 25 El bz Ee merson Netwon ower Intelli e r the IP address or hostname of the Web card in the address n seod Sewr RS bar e g http 192 168 0 125 2 Click on the Configure tab shown at right Configuration EMERSON monitor control configure support Configuration Categories Agent Information Categories appear in the left panel organized with folder Bg 2 Fera ot elena daneyan ry mere icons 192 168 0 125 Category Description 7 j i an J Agent Info identification parameters name locatior 3 a Click on any configuration cate gory and the Connect To A Factory Defaults Reset the configuration to factory default box opens 4 Enter the Administrator username and password both case sensitive a User Name default is Liebert No Alarms Present Firmware Update the communication card firmware Update Updating the firmware will allow the com well as periodic maintenance releases Configuration Categories IP Settings Identify the network address netmask z E Data Room LPS Proper configuration allows this device tc a and LINP haced nrotacale E srd Update jy SET 2x roto Web Pr FA Me 4 b Password default is Liebert po j r gan VV N OTE Tene italia azar
22. appears as shown in the following example Press the Enter key to return to the previous menu 00 00 68 16 82 C1 IntelliSlot web Card MAC Address Network Card Model Factory Settings Menu 1 Reset to Factory Defaults 2 Agent Card Information lt ESC gt Cancel menu level Please select a key gt Network Card Part OCWEBCARD Manufacture Date APR 28 2004 Serial Number 416701G105T2004APR280074 Boot Version 2 300 0 Boot Label OCWEBCARD_HID3_2 300 0_034380 App Version 2 300 0 App Label OCWEBCARD_HID3_2 300 0_035191 Hardware Version 3 CPU Speed 50 MHz Flash Usage Hit Enter to Exit 4327 Out Of 8388 KByte Ey Web Interface To view Web card information through the Web interface e Click on the Support tab then Summary in the left panel The Web card information appears in the right panel Support tab Listing in right panel Summary Loo o EMERSON monitor control configure support Agent Information STE Data Room UPS Bldg 2 Floor 4 Supports Server02 192 168 0 125 Value Data Room UPS Bldg 2 Floor 4 Supports Server02 Network Svcs x100 Liebert Corporation Agent Model IntelliSlot Web Card Agent Part Number OCWEBCARD Agent App Firmware Version i 2 300 0 OCWEBCARD_HID3_2 300 0_035191 Agent Boot Firmware Version 2 300 0 Agent Boot Firmware Label OCWEBCARD HID3_2 300 0 034380 Agent Hardware ID 3 416701G105T2004APR280074 Agent Manufacture Date APR 28 2004 Age
23. each function After making changes return to the Main Menu and choose Exit and Name COM3 Connection settings Configuration Overview Connection Description E 2 xl Enter a name and choose an icon for the connection Name GXT2U AA a B GXT2U Enter details for the phone number that you want to dial Country region United States 1 Area code EE Phone number TERH Connect using hd EA a COM3 Properties 2 x Port Settings SS gi Data bits le y Party None y Stop bits hy Flow control Negra ha Restore Defaults RTCS v2 96 00 Telnet server service Port Manager Active System Information lt Esc gt Ends Session Main Menu Save to reboot the Web card and put your changes into effect see 3 6 Saving Changes and Reinitializing the Web Card 1 2 IP Network Settings 3 Messaging 4 Factory Settings 5 Firmware Updates Quit and abort changes Exit and save xO Please select a key gt 3 3 Configuration Overview LD Open the Terminal Emulation Interface TCP IP Connection To access configuration using terminal emulation software with CETTE ax an Ethernet connection to the Web card Enter a name and choose an icon for the connection 1 Open a terminal emulation application such as Name HyperTerminal Name E To do this e Click the Start button then Programs Accessories Communications and fina
24. for the sending of RFC 1628 MIB traps RFC 1628 is an IETF proposed standard for UPS information RFC 1628 MIB Traps Note For proper operation of Multi Linkand Nformthis feature must be enabled Liebert Global Products Enable or disable support for retrieval of data using the Liebert Global Products LGP LGP MIB MIB objects Liebert Global Products Enable or disable support for the Liebert Global Products LGP MIB Traps Note that if a heart beat trap is enabled for a trap target and this LGP feature is disabled the heart beat trap will still be sent Liebert Global Products Enable or disable support for the LGP System Notification Trap This is a single trap LGP System Notify that is sent each time a condition alarm warning is added or removed from the Trap conditions table A varbind in this trap will contain a text description of the condition Save Reset Authentication Traps enabled Heartbeat Trap Interval List sets RFC 1628 MIB enabled frequency of Traps enabled Heartbeat Liebert Global Products LGP MIB enabled Tra ps Traps enabled System Notify Trap enabled 16 Network Settings SNMP Communications Menu Use the SNMP Communications Menu to enable authentication traps and view or change communi ties and trap communities events and parameters For details on viewing support information see 9 2 Events and Parameters Table 12 SNMP communicatio
25. from the Main Menu 2 Select an option then use the following guide to make changes Please select a key gt Table 18 Messaging menu guide CI A E Mail Configuration page 29 SMS Configuration page 30 Customize Messages E Mail and SMS page 32 2 Web Interface To access Messaging settings through the Web interface Click on the Configure tab then Messaging in the left panel and finally Edit in the right panel After making changes click Save Configure tab TT a amp EMERSON monitor control configure event log support Agent Information Messaging SNMP_Test SNMP_Test3 Category Description SNMP_Test4 192 168 0 25 Email Configure email parameters SMS Configure SMS parameters Device Status Customize Message Customize the message sent to Email or Load Protected No Alarms Present Parameter Description Email Enable or disable Email notification sy Enable or disable Short Message Service A nn yn Cea Edit Configuration Categories lii SNMP_Test Eanes enabled im Agent Information SMS enabled mm Factory Defaults m Firmware Update ma Web Ea Network Settings m DNS im Test mm Time SNTP Messag l ng lm Management Protocol SNMP m Access Traps im Messaging n Email m SMS im Customize Message 28 Messaging 6 1 E Mail Configuration Email Configuration Menu Email From Uninitialized Email Message Recipients Email Subject
26. gt Cancel menu level Please select a key gt All Code In Flash will Be Rewritten Confirm y n TFTP Update initiated The firmware on this card is currently being updated This operation may take 6 or more minutes depending on network traffic and other factors The card will be rebooted upon successful completion of the process OR control will be returned to this terminal session upon failure so another firmware update attempt can be made Firmware update in process Percent Complete 0 Main Menu System Information TP Network Settings Messaging Factory Settings Firmware Updates Quit and abort changes Exit and save Please select a key gt To update the Liebert IntelliSlot card firmware using the TFTP method with a Web interface Open a Connection to the Card 1 Open a connection to the Liebert IntelliSlot card f needed see instructions in A 2 4 Open the Web Interface 2 Click on the Configure tab then TFTP in the left panel Configure tab EMERSON monitor Agent Information Data Room UPS Bldg 2 Floor 4 Supports Server02 Server control Parameter Description IP address of the TFTP server configure support Network TFTP Firmware Download 192 168 0 125 Port Port server is listening on typically 69 Device Status Load Protected No Alarms Present Name of the firmware update file Note The maximum
27. length of the entry is 128 characters including sp Configuration Categories IE Data Room UPS TFTP Agent Info Factory Defaults Firmware Update la Web Bin P Settings Edit 3 Enter the Administrator username and password both are case sensitive a Login username default is Liebert b Password default is Liebert A7 Updating the Firmware TFTP HyperTerminal Telnet Web Method Specify TFTP Server and Upgrade Filename 4 Click the Edit button in the right panel 5 Select options as needed and refer to the following guide to change any settings Table A5 Firmware update settings Web The IP address of the TFTP server for example 192 168 0 125 Port Port that the TFTP server is using typically 69 Name of the firmware update file 128 characters maximum including spaces and punctuation This is the file with the extension bin downloaded in A 3 3 Download the Firmware Upgrade File to the Computer 6 After making changes click Save then click Reinitialize in the left panel to reboot the card Configure tab EMERSON Network Power monitor control configure support A ae Network TFTP Firmware Download gent Information Data Room UPS Bldg 2 Floor 4 Parameter Description Supports Server02 Server IP address of the TFTP server 192 168 0 125 Port Port server is listening on typically 69 Device Status Filename Name o
28. n e aren bonita pe j Messaging MA rre cd ate sic authentication For security change the default username and Bos E g dn password see 5 7 Change Username Password 5 Click OK 6 Refer to 3 1 Guide to Configuration for details on each function 7 After making changes click the Save button then click on Categories Reinitialize to reboot the Web card and put your changes into effect see 3 6 Saving Changes and Reinitializing the Web Card Customize Massana Password Configuration Connect To Reinitialize to save any changes 3 6 Saving Changes and Reinitializing the Web Card Follow the applicable steps for your interface to save configuration changes and reinitialize the Web card Changes will not take effect until these steps are completed En LS Terminal Emulation Serial or TCP IP Connection Telnet kew settings will take effect when saved After each change is made a reminder appears shown at right Go To MAIN MENU AND DO EXIT AND Return to the Main Menu then choose Exit and Save A mes SAVE TO SAVE YOUR CHANGES sage appears and remains until the card is reinitialized followed Exiting and saving by a message that the process was successful Configuration saved successfully Ey Web Interface After making each change click the Save button A reminder e e xl appears each time you make a change shown at right Notice Reinitialization
29. of event limit Range 10 to 120 Message Consolidation Time Limit on page 33 Consolidation Number of events to consolidate before sending a notification Event Limit Notification will be sent when this threshold is reached regardless of time limit Range 1 to 50 Message Consolidation Time Limit on page 33 32 Messaging Ey Web Interface To access Customize Message settings through the Web interface e Click on the Configure tab then Customize Messages in the left panel and finally Edit in the right panel Choose the items to include in each type of message in the Email and SMS columns After making changes click Save Configure tab EMERSON Network Power monitor control configure event log Agent Information Messaging gt gt Customize Message SNMP_Test SNMP_Test3 Parameter Description SNMP_Test4 192 168 0 25 IP Address If checked the IP Address of the agent card wi Event Description If checked SNMP event description will be incl Device Status Name If checked the agent card Name will be include pod Frotoctod c if checked th rd Contact will be incl EAER ontact checked the agent card Contact wi inclu Location If checked the agent card Location will be inch Description If checked the agent card Description will be ir Web Link amp Port If checked a Web link to the agent card and Y included in outgoing messages Configuration Categories E
30. of the system is required for new settings to ke effect li ion ch have b de Without leaving the Configure tab window below left click a PE Reinitialize in the left panel then click the Reinitialize button at right to reboot the Web card and put your changes into effect EMERSON monitor control Agent Information Newa Data Room UPS configure support Bldg 2 Floor 4 Parameter Description Supports Server02 Reinitialize Clicking this button will reboot the card and 192 168 0 125 Device Status Reinitialize First click Rei n iti al ize Ne Alan Dersok at left Configuration Categories Data Room UPS En Agent Info Factory Defaults En Firmware Update Web z TFTP T P Settings EH Management Protocol SNMP Access Traps Messaging Email SMS Customize Then click Reinitialize button https 192 168 0 125 config configReinitialize htm on the navigation menu Progress message window amp EMERSON W Liebert The web card is attempting to reinitialize If this message appears for more than 2 minutes you may need to restart your browser connection or contact your network administrator for assistance If further assistance is necessary visit Liebert com Last updated Tuesday July 24 2007 02 37 05pm TT internet 4 100 A message window appears shown above right and remains until the card is reinitialized 10 Syst
31. one line Example Enter a to add an entry then press Enter a 10 0 0 5 162 publicl Enter the IP address or hostname of the device to be added then press then press Enter Enter Enter the port number default is 162 then press Enter Enter the community string then press Enter Edit a device see example at right to enter all parameters in one line Example Enter e to edit an entry then press Enter e 2 10 0 0 7 162 public2 Type the Entry Number then press Enter then press Enter Enter the new IP address or hostname then press Enter Enter the port number default is 162 then press Enter Enter the new community string then press Enter Delete a device see example at right to enter parameters in one line Example Enter d then press Enter No confirmation message will appear d 2 Type the Entry Number then press Enter then press Enter 18 Network Settings 5 4 Web Server web Server Menu Use the Web Server Menu to configure access to the card web Server Mode HTTP Not Secure i T HTTP Transport Port 80 through the Web interface Consult your network adminis 3 Password a site disabled Configuration Control enabled trator if needed Refresh Rate 30 seconds j i lt ESC gt Cancel menu level 5 4 1 Specify Web Server Settings Please select a key gt EM amp Terminal Emulation Serial or TCP IP Connection Telnet To change any parameters 1 Choose IP Network Settings f
32. supported param eters for the Liebert unit as in the example at right These parameters vary according to the Liebert unit where the card is installed Ey Web Interface To view events and parameters through the Web interface e Click on the Support tab then Events or Parameters in the left panel The events or parame SNMP Communications Menu Authentication Traps no Display Modify Communities Display Modify Trap Communities Support Information lt ESC gt Cancel menu level Please select a key gt support Information Menu Display Events Display Parameters Total Events Total Parameters Total Objects lt ESC gt Cancel menu level Please select a key gt Display Events Example AlarmOnBypass 1 3 6 1 2 1 33 1 6 3 9 lgpAgentDeviceCommunicationLost 1 3 6 1 4 1 476 1 42 2 3 0 1 Hit any key to continue Display Parameters Example sysDescr 1 3 6 1 2 1 1 1 0 sysObjectID 1 3 6 1 2 1 1 2 0 Hit any key to continue ters are listed in the right panel The example below shows a list of Events Support tab A EMERSON monitor control configure SNMP Events support Agent Information Data Room UPS Bldg 2 Floor 4 Supports Server02 192 168 0 125 SNMP Events coldStart 1 3 6 1 6 3 1 1 5 1 upsAlarmBatteryBad 1 3 6 1 2 1 33 1 6 3 1 upsAlarmBypassBad 1 3 6 1 2 1 33 1 6 3 10 upsAlarmUpsOutputOff 1 3 6 1 2 1 33 1 6 3 14 upsAlarmD
33. tok A dal d ne te bane wan tha ele ewes 6 D2 Open the Terminal Emulation Interface Serial Connection 0 0 00 00 0000 eee T 3 3 Open the Terminal Emulation Interface TCP IP Connection 0 8 3 4 Open the Telnet Interface civ o ee Sela se Ga ti bn h W bee 9 3 5 Open the Web Interface incita air KK KK bak Gade Eas Choe kk a a SS 10 3 6 Saving Changes and Reinitializing the Web Card RR RR YR YR KV KK ee 10 4 0 SYSTEM INFORMATION 4 uk kk kk kk kk a kk eee eae edad od a a a a kk eee ee kk a 11 59 0 NETWORK SETTINGS 3aqa ss kn ar IS Ae 12 5 1 Boor IP o U ee IS RR ge 13 OZ Domain Name Server DNS Settings kk KK KK KK KK KK KK KK KK kk kk kk kk kk a 14 5 3 Management Protocols i kun acc aw Y d y oon diw r dan aaa 15 5 4 Ms o sansa IN O E 19 5 0 a A rRrsrRrRssRrRare 24 5 6 Tine NTE MeD ala a a AAA daa 24 5 7 Change Username Password ccc KK KK KK kk kk kk nee 26 5 8 Reset Authentication to Factory Defaults k kk kK KK KK KK KI KK KI KI KK KK KK KK KK KK 27 6 0 MESSAGING es as aa a aa aw od Dien de 28 6 1 EMalConio urat SS tetitas bb 29 6 2 SMS CONT SUTTON A ys Gye he id AS BA ears GA EH AE 30 6 3 Customize Messades sanitaria ees oe owls Ch eae teas cue L AN v r es 32 LO FACTORY SETTINGS a 34 7 1 Reset to Factory Detaults ir A KO qw kk W k EEE dila
34. we we Emerson Network Power IntelliSlot Web Card Configure and 5 Support Tabs EMERSON A 3 PREPARING TO UPDATE LIEBERT NTELLISLOT FIRMWARE A 3 1 Requirements to Update the Liebert IntelliSlot Card s Firmware Make sure you have the following before starting the update monitor Agent Information Uninitialized Summary Uninitialized Uninitialized 192 168 0 125 Device Status Load Protected No Alarms Present Monitor Categories m GXT l Summary Active Alarms Battery BATTERY Volts 55 3 V Charge 100 Time Remaining 41 min OUTPUT _ Configuration Other Active Alarms No Alarms Present Firmware upgrade downloaded from Liebert s Web site see A 3 3 Download the Firmware Upgrade File to the Computer A computer running Internet Explorer 5 5 or newer A Liebert IntelliSlot card Aconnection to the Liebert IntelliSlot card e Null modem cable serial upgrade method Ethernet connection TFTP or HTTP upgrade method An Internet connection Preparing to Update Liebert IntelliSlot Firmware A 3 2 Determine the Liebert IntelliSlot Card Type and Firmware Version Each type of Liebert IntelliSlot card uses different firmware Attempting to upgrade a card with the firmware for another type of card will fail and may damage the card To determine the type of card in your Liebert equipment EM Gp Terminal Emulation Serial or TCP IP
35. 0HT 120 Table 2 Communication settings Main Menu Baud Rate 9600 System Information IP Network Settings Messaging Factory Settings Firmware Updates Quit and abort changes x Exit and save Flow Control Press the Enter key for the Main Menu above i Ti ght Emerson Network Power HyperTerminal Joa Please select a key gt Connected 0 00 46 ANSI 9600 S N 1 Select IP Network Settings then Boot IP 05 a Settings and follow the instructions to enter an IP ADDRESS NETMASK and GATEWAY Emerson Network Power IntelliSlot Heb Card GXT1000MT 120 Press Esc to return to the Main Menu Pira e Choose Exit and Save to save your changes Boot IP Settings Hanagement Protocol and reboot the card Web Server Telnet Server Change Administrator Username Password Installation 2 2 Install a Liebert IntelliSlot Web 485 Card With Adapter A WARNING Risk of electric shock Can cause equipment damage injury or death Service and maintenance work must be performed only by properly trained and qualified personnel and in accordance with applicable regulations and manufacturers specifications Opening or removing the covers to any equipment may expose personnel to lethal voltages within the unit even when it is apparently not operating and the input wiring is disconnected from the electrical source Check the circuits with a voltmeter before beginning installat
36. 7 Table A1 Overview of the upgrade process k kk kK KK KK KK ee ee kk kk eee nee Al Table A2 Estimated Time for downloads Sk kk kK KK KK ee kk K eee ee Al TableAS Communication settines kak A bees Wi S A se ote eee hues eG aud A2 Table A4 Firmware update settings TFTP uds kK KK KEK KK KI KI KI KK KK KK KK KK KK KK KK KK KK kk A6 Table A5 Firmware update settings Web oo idee eee KK KK KK KK kk kk kk kk k on A8 ii MPORTANT SAFETY NSTRUCTIONS SAVE THESE INSTRUCTIONS A WARNING Only a qualified service professional should install these products Liebert recommends having an Emerson Network Power Liebert Services representative perform the installation in large UPSs Contact Liebert Services at 1 800 LIEBERT 1 800 543 2378 A WARNING Risk of electric shock Can cause equipment damage injury or death Service and maintenance work must be performed only by properly trained and qualified personnel and in accordance with applicable regulations and manufacturers specifications Opening or removing the covers to any equipment may expose personnel to lethal voltages within the unit even when it is apparently not operating and the input wiring is disconnected from the electrical source Check the circuits with a voltmeter before beginning installation Introduction 1 0 INTRODUCTION The Liebert IntelliSlot Web
37. Connection Telnet ean Seo en To view Web card information using terminal emulation or Telnet 1 Reset to Factory Defaults 2 Agent Card Information 1 Open a connection to the Liebert IntelliSlot card Gf needed see ees Caneel Henn Teve instructions in A 2 1 Open the Terminal Emulation Interface Serial Connection A 2 2 Open the Terminal Emulation Interface TCP IP Connection or A 2 3 Open the Telnet Interface 2 Choose Factory Settings from the Main Menu then choose Agent Card Information 3 The Liebert IntelliSlot card model part number and firmware version appear in the following example Press the Enter key to return to the previous menu Please select a key gt AC _Addre 00 00 68 16 82 etwork Card Model IntelliSlot web Card etwork Card Part OCWEBCARD anutacture Date APR 28 2004 Model and Serial Number 416701G105T2004APR280074 Part Number Boot Version 2 300 0 Boot Label OCWEBCARD_HID3_2 300 0_034380 App Version 2 300 0 Kpp Labe OCWEBCARD_HID3_2 300 0_035191 Firmware a a i CPU Spee 50 MHz Merson Flash Usage 4327 Out Of 8388 KByte Hit Enter to Exit Ey Web Interface To view Web card information using a Web browser 1 Open a connection to the Liebert IntelliSlot card Gf needed see instructions in A 2 4 Open the Web Interface 2 Click on the Support tab then Summary in the left panel The Liebert IntelliSlot card model part number and firmware version appear in the right panel
38. Event Log at the top of the page includes two links txt and csv The Txt link will download the entire event history in unformatted text The CSV link will download the entire event history in comma separated format which can then be imported into an application such as Microsoft Excel Scroll through Event Log Event Log tab EMERSON Liebert Network Power monitor control configure event log support Agent Information ggent Event Log txt csv Updated June 24 2008 09 55 13AM SNMP_Test SNMP_Test3 lt s lt Pagetort gt gt SNMP_Test4 192 168 0 25 Sent SNMP Trap IgpSysEventNotifications Message System Return to Device Status Wana n paa ia e Normal to Trap Recipient List Mo Alarms Present 0 00 34 SysUpTime 4 Sent SNMP Trap lgpSysEventNotification lgpSysNormal to Trap an kk daka Recipient List 38 9 0 SUPPORT NFORMATION Support Information Support data includes identifying information for the Web card as well as events and parameters available for the Liebert equipment 9 1 View Web Card Information Identifying information for the Web card may be viewed through any interface and includes the MAC address model and part number serial number and firmware version EN Q Terminal Emulation Serial or TCP IP Connection Telnet To view Web card information 1 Choose Factory Settings from the Main Menu then choose Agent Card Information 2 The Web card information
39. IP address or domain name of the SMTP e mail server that sends messages ae characters After saving changes to SMS parameters send a test SMS message to verify the Test SMS settings are correct The message status will be displayed View Test l SMS Log File Choose this option to display a log showing the results of test messages EEE Ey Web Interface To access SMS Configuration through the Web interface e Click on the Configure tab then SMS in the left panel and finally Edit in the right panel After making changes click Save Configure tab AAA E J configure event log support p Liebert monitor control Agent Information Messaging gt gt Short Message Service SMS SNMP_Test SNMP_Test3 SNMP_Test4 192 168 0 25 Parameter Description SMS From Sender s email address ln most cases this will be the email address of the person to whom replies should be sent For Device Status Load Protected No Alarms Present Edit xam n l MS Text Message address of the recipients Usually a 10 digit phone number followed by MessagingCompanyName com For example 1112223333 messagingCompany com Multiple SMS addresses should be separated by a semicolon K lt Note The maximum length for a SMS address entry is 64 characters Configuration Categories Subject lE SNMP_Test im Agent Information m Factory Defaults m Firmware Update cane Subject of the message
40. LE EE EEE EEE EEE ELE EEE 111 298K of 350K meden Elapsed 00 01 00 Remaining 00 00 10 Throughput 5085 Zmodem lapsed 01 emaining 00 roughput cps Please select Zmodem with Crash Recdyer Changing Communications Ratt My Documents F Cancel Press Enter to Start Firmware Npdate i CCEC 3 My Computer gt Progress and Connected 01 55 ANSIW 115200 8 N 1 NUM E l a E y File name DOWEBCARD_HID3_2 300 0_035760_FILE1 s19 n window remainin g My Network Files of type All Files v Cancel E E ress Enter rl Choose Lem shows time irmware update i p 1K Xmodem elapsed time 14 Click the Browse button to locate an upgrade file Select the files in order the filename ending n FILE1 for the first download then FILE2 and finally FILE3 then click Open 15 In the Send File window choose 1K Xmodem from the Protocol drop down list and click Send A progress window opens showing the elapsed time and amount of time remaining for the first file to be downloaded to the Liebert IntelliSlot card The window closes after the first file 1s down loaded Do not press any keys while the progress window remains open or the download will abort Q NOTE Download the Second and Third Firmware Update Files 16 When the progress window closes enter y yes in E 18 19 20 21 HyperTerminal to continue the upgrade Choose Xmodem1K in the Select Firmware Update Protocol menu The screen shows that
41. Slot Web card non adapter version P N IS WEBCARD IS WEBLB and IS WEBLBDS 1 h 2 1 1 Connect the Cable 1 2 1 2 Prepare the Card for Configuration Change General Username Password NOTE Reset Authentication to Factory Defaults When installing the card in a Liebert NX ae lt ESC gt Cancel level configure the communication port of NX to ci Pl lect a key gt 2400 baud See the NX user manual for gt detal S Connected 0 01 46 ANSI 9600 8 N 1 Locate the Liebert IntelliSlot option bay on your Liebert equipment You might need to remove a plastic cover Insert the Liebert IntelliSlot Web Card into the Liebert IntelliSlot bay Secure the card with the supplied screws Connect an Ethernet cable DHCP The card ships with DHCP service enabled The MAC address is on a sticker on the top of the card OR Static IP To assign a static IP address or hostname use terminal emulation software to configure the card as described in Sections 2 1 1 and 2 1 2 Locate the blue serial configuration cable null modem that shipped with the card Connect the configuration cable to the DB 9 port on the card and to a COM port on your PC ES Emerson Network Power HyperTerminal Quay Use terminal emulation software such as Ele Eit Yew Cal Tente Heb aD Y Microsoft HyperTerminal to open a connection to the card with the sett ngs n Emerson Network Power IntelliSlot Web Card Table 2 GXT100
42. TC Cancel menu level Network Settings En Gp Terminal Emulation Serial or TCP IP Connection Telnet To change this setting 1 Choose IP Network Settings from the Main Menu then Time SNTP 2 Choose SNTP Time Synch Rate then specify Hourly Daily 3 Choose Time Server then specify the new time server if desired 4 Choose Time Zone select a region from the list and then select a time zone Table 14 Time Server parameters Description Telnet Menus SNTP Time Sync Rate lib is how often the card will attempt to synchronize its internal clock with the specified ime server Time Saver This is the server that will be used for synchronization This can be either an IP address or a hostname provided that the DNS options are configured This is the local Time Zone that will be used to correctly adjust the time provided by the server for the locale where the Web Card is being used Time Zone Ey Web Interface To access Time SNTP settings through the Web interface Click on the Configure tab then Network Settings in the left panel and finally Edit in the right panel After making changes click Save Configure tab Ku EMERSON a Network Powe monitor control configure event log support Agent Information Network Settings gt gt Time SNTP SNMP_Test SNMP Test3 Parameter Description P ime Server simple Network Time Servers SNTP IP address or ne
43. address of the name server for network which should be obtained ls ii Server DNS from your network administrator gt om ib PRN DNS Resolve Interval Interval to reresolve DNS addresses from a network name to an IP Address Firmware Update DNS Naming T Domain Name Suffix Domain suffix lf specified only the hostname s need to be entered rather than the lifi mai FQDN rk na in o figuration fields Network gt Network Satlings fully qualified domain QDN for netwo in other configuration ds DNS 5 Acceptable values consists of 4 numbers ranging from 0 to 255 separated with a i Sett Obtain ett ngs Test character As an example 10 0 0 1 dd z Time SNTP Ear address Click Edit Management Protocol Save automatically to change SNMP DNS Server settings i Obtain DNS server addresses automatically Messaging Use the following DNS server addresses Specify Email a Primary Domain Name Server DNS 65 24 7 10 address Customize Message Secondary Domain Name Server DNS 65 24 7 11 Reinitialize R Telnet Resolve Interval Options for Users how long Web DNS Naming card retains Domain Name Suffix resolved addresses 5 3 Management Protocol Management Protocol Menu The Management Protocol Menu allows you to enable or disable a e el B R ae enabled SNMP and configure management protocols Consult your network Nae lt ESC gt Cancel menu level administrator for these settings Please select a key gt
44. ade File The amount of time required to download the firmware upgrade file depends on the upgrade method used Refer to Table A2 for estimated times for each method Table A2 Estimated Time for downloads Upgrade Method Expected Speed HTTP Web Method 6 7 minutes bin file subject to network traffic TFTP HyperTerminal Telnet Web Method 5 6 minutes bin file subject to network traffic 1st file 2 minutes Xmodem 1K 115 200 bps 2nd file 2 minutes 3rd file 3 5 minutes A1 Connect to the Card Terminal Emulation Telnet or Web Interface A 2 CONNECT TO THE CARD TERMINAL EMULATION TELNET OR WEB INTERFACE Upgrading the firmware requires connecting to the card with one of these interfaces A 2 1 Gp Open the Terminal Emulation Interface Serial Connection To connect to the card using terminal emulation software with a a serial connection to the Web card OO Neu conection 1 Open a terminal emulation application such as N ing gaia gags n nicl HyperTerminal ere GER To do this e Click the Start button then Programs Accessories Communications and finally HyperTerminal 2 Inthe Connection Description window enter a name for the 212 connection for example GXT2U then click OK Bow 3 Inthe Connect To window J e Choose COM3 from the Connect Using drop down list Asa code fF bet ll Tn e Click OK COM3 i 4 Inthe COM8 Properties window enter the communication BER JE EB s
45. and begin transferring the upgrade files Q NOTE After you begin the initialization process in Step 12 you must complete Steps 13 through 15 within 60 seconds Before beginning check to ensure that you know the location of the firmware files and read through the following steps to understand what needs to be done This 60 second limit also applies to downloading the second and third upgrade files 13 In the HyperTerminal menu click on Transfer then Send File Press a number 1 9600 bps to Change Communications Rate Browse to locate upgrade file 5 meg L 1K Xmodem file send for com1connexion ps E ona te Send File Select File to Send Sending E 0 LiebertServer03ntellislotFimwareUpdates0CWEBCARD_HID3_25 ps z Folder E 40 Look in OCWEBCARD_HID3_2 v BF Enter Accep Ne aan 2 Ll Q a gt E Packet 301 Error checking CRC AO Liet islotFi Browse 2 EE OQPEBCARD_HID3_2 300 0_035780_AppFwUpdt bin Instructions EL mao rde Alem L2 zl OCWEBCARD_HID3_2 300 0_035780 _FILE1 s19 Reties 0 Totalreties 0 Select New Protocol My Recent SH OCWEBCARD_HID3_2 300 0_035780_FILE2 519 Disconnect 1K Xmodem v Documents E OCWEBCARD_HID3_2 300 0_035780_FILE3 s19 Last error Change 1p lew Rate E OCWEBCARD_HID3_2 300 0_035780_U64 exo Reconnect Y 2 Peres Enten meres File Bl l E E E
46. ccess Community address read write string Codes for lt a gt dd lt d gt elete lt e gt dit Complex lines allowed e g lt a 198 1 1 1 write public gt gt editing Each device is identified by Entry Number use the entry number 1 20 to edit or delete an entry IP address or Hostname the address of the device with access MultiLink server Nform server Network Management System e Access read write read allows users to view but not change data write allows full permission for configuration control and viewing e Community string the community string used by the IP host for this Entry Number case sensitive up to 32 characters To make changes Add a device see example at right to enter all parameters in one line Example Enter a to add an entry then press Enter a 10 0 0 5 write publicl Enter the IP address or hostname of the device to be added then press then press Enter Enter Enter 1 for read or 2 for write access for this device then press Enter Enter the community string then press Enter 17 Network Settings Edit a device see example at right to enter all parameters in one line Example Enter e to edit an entry then press Enter e 2 10 0 0 7 read public2 Type the Entry Number then press Enter then press Enter Enter the new IP address or hostname then press Enter Enter 1 for read or 2 for write access for this device then press Enter Enter the new community
47. click OK then click OK to close the Properties window In the HyperTerminal menu bar click on Call then choose Call from the drop down menu and press the Enter key Call menu COA Properties Ax Connect To Settings B com connexion Change Icon r Current Communications Rate is 9600 bps Press a number to Change Communications Rate Fea VE ORA E a KA DB Phone number Enter Accept Start Firmware Update Instructions to Change Communications Rate Select New Communications Rate Disconnect Terminal Window Change Terminal Communications Rate to Match New Rate Reconnect Terminal Window Press Enter Please select a key gt Changing Communications Rate to 115200 bps Restore Defaults Configure OK Cancel button a 19200 bps 38400 bps 97600 bps COM1 Properties LEJ Port Settings Country region Enter the area code without the long distance prefix Area code Bits per second 115200 w 9600 bps Data bits Connect using COM1 115200 bps 115200 bps Parity Stop bits Flow control 921600 a anka A10 Download the First Firmware Update File 12 After changing the communication rate to 115200 bps press Enter to resume the firmware update Updating the Firmware Xmodem Serial Method After you press Enter HyperTerminal displays Cs as it counts down the time remaining to locate
48. d with the settings in Table 3 2 Press the Enter key for the Main Menu Select 485 Network Settings to access the Stop Bits communications settings Flow Control Select Enabled Application u Select Modbus Server to enable the Modbus application At the next screen select Server ID the default Server ID is 1 but may be any number up to 255 Press Esc to return to the Main Menu Select IP Network Settings then Boot IP Settings and follow the instructions to enter an IP ADDRESS NETMASK and GATEWAY 9 Press Esc to return to the Main Menu oS Se i a 10 Choose Exit and Save to save your changes and reboot the card NOTE When installing the card in a Liebert NX configure the communication port of NX to 2400 baud See the NX user manual for details Configuration Overview 3 0 CONFIGURATION OVERVIEW 3 1 You may use any of the following interfaces to configure the Web card Table 4 Configuration interfaces Available Connection Description Functions Methods Terminal Emulation Use terminal emulation software l l Serial Cable Serial or TCP IP for example HyperTerminal Celte alen or TCP IP Use a command prompt enter i i telnet and the IP address or hostname Configuration TCP IP Use a Web browser for example Configuration TGP IP Microsoft Windows Internet Explorer Monitoring Control Each configuration section provides instructions using the Terminal Emulation Serial or TCP IP C
49. d again 1f needed see A 2 3 Open the Telnet Interface or A 2 1 Open the Terminal Emulation Interface Serial Connection 9 Choose Firmware Updates from the Main Menu 10 Choose TFTP Update from the Firmware Updates menu shown at right Firmware Updates Menu 1 TFTP Update A6 Updating the Firmware TFTP HyperTerminal Telnet Web Method A 5 2 Begin the Upgrade Process 11 When ready to begin the update choose Initiate TFTP Firmware Update 12 Open the TFTP application and start TFTP Ensure that all settings are ready to transfer the file including the location of the upgrade file Refer to your TFTP user manual for more details 13 Return to the terminal emulation Telnet screen At the confirmation message prompt enter y yes to confirm your choice To cancel enter n for no 14 A message appears as shown at right showing the progress by percent complete 15 When the progress screen shows 100 complete the card will be rebooted Press Enter when this is finished 16 Press the Escape key to return to the Main Menu then choose Exit and Save The upgrade is now complete Check the new firmware version if you wish see A 3 2 Determine the Liebert IntelliSlot Card Type and Firmware Version 2 TFTP Method Web Interface TFTP Update Menu IP Address 192 168 0 125 Port 69 Filename OCWEBCARD_HID3_2 300 0_035780_AppFwUpdt bin Initiate TFTP Firmware Update lt ESC
50. d with the card or by reading the card s support information through a terminal emulation Telnet or Web interface as described in A 3 2 Determine the Lie bert IntelliSlot Card Type and Firmware Version NOTE Liebert recommends that users read all the instructions prior to attempting a firmware upgrade Overview The firmware upgrade involves these steps Table A1 Overview of the upgrade process 1 Decide which interface to use to connect to the A 2 Connect to the Card Terminal Emulation Telnet Liebert IntelliSlot card or Web Interface 2 Prepare for the upgrade Make sure you have everything needed to A 3 1 Requirements to Update the Liebert IntelliSlot perform the upgrade Card s Firmware e Check the type of card and firmware version A 3 2 Determine the Liebert IntelliSlot Card Type and currently installed Firmware Version e Download the upgrade file from Liebert s Web A 3 3 Download the Firmware Upgrade File to the site Computer Decide which method to use for the upgrade RET astra a Method to Install the Firmware 3 Follow the step by step instructions to upgrade the firmware with the chosen method e HTTP Web Method A 4 Updating the Firmware HTTP Web Method j E A 5 Updating the Firmware TFTP HyperTerminal TFTP HyperTerminal Telnet Web Method Telnet Web Method Xmodem Serial Method A 6 Updating the Firmware Xmodem Serial Method Estimated Time to Download the Firmware Upgr
51. earborn Drive P O Box 29186 Columbus OH 43229 Europe Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco PD Italy 39 0499719111 While every precaution has been taken to ensure the accuracy Z and completeness of this literature Liebert Corporation assumes no Fax 39 049 5841 251 responsibility and disclaims all liability for damages resulting from use of Asia this information or for any errors or omissions 7 F Dah Sing Financial Centre 2008 Liebert Corporation A 108 Gloucester Road Wanchai All rights reserved throughout the world Specifications subject to change H K without notice ong Kong O Liebert is a registered trademark of Liebert Corporation 852 2572220 All names referred to are trademarks Fax 852 28029250 or registered trademarks of their respective owners S1 52615_REVO2_08 08 Emerson Network Power The global leader in enabling Business Critical Continuity EmersonNetworkPower com m AC Power Embedded Computing Outside Plant Racks Integrated Cabinets Connectivity Embedded Power Power Switching amp Controls Services DC Power Monitoring Precision Cooling Surge Protection Business Critical Continuity Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co 2008 Emerson Electric Co
52. em Information 4 0 SYSTEM NFORMATION System Information is optional and identifies the Liebert unit its location a contact person and other information about the unit The default value of each field is Uninitialized NOTE This information also configures the SNMP parameters sysName sysContact sysDescr and sysLocation available using RFC 1213 MIB II EN Q Terminal Emulation Serial or TCP IP Connection Telnet To edit any field in this category 1 From the Main Menu choose System Information System Information Menu Uninitialized Contact Uninitialized Location Uninitialized Description Uninitialized lt ESC gt Cancel menu level Please select a key gt 2 Enter the number that corresponds to your choice then enter the identifying information using the following as a guide Table 7 System information identifiers Name A name A name for the Liebert unit o the Liebert unit 255 characters characters EL contact person or is ___ responsible for maintenance and operation of the Liebert unit 64 characters The location of the Liebert unit 64 characters Other useful information about the unit Description 64 characters for quick reference Valid characters include spaces and other printable characters except double quotes 2 Web Interface To access System Information through the Web interface Click on the Configure tab then Agent Info in the left panel and finall
53. entry is 128 characters including sp Reset Update Configuration Categories A Firmware E Data Room UPS Server 1 192 168 0 15 Agent Info Factory Defaults Port 69 Firmware Update Web Filename OCWEBCARD_HID3_2 300 0_035780_AppFwUpdtbin TFTP A8 A 6 Updating the Firmware Xmodem Serial Method 11 During the update the window displays a progress bar as shown below left NOTE Do not close the Web browser during this process or the update will abort After the firmware update is completed the card will reinitialize automatically A reboot mes sage as shown below right remains until the rebooting is finished EMERSON Network Power monitor control configure support EMERSON Agent Information Network TFTP Firmware Update Status Network Power Data Room UPS Bldg 2 Floor 4 Firmware Update Progress Supports Server02 192 168 0 125 A W Liebert Device Status Load Protected No Alarms Present File Size 3309740 Bytes Programmed 659000 Percent Complete 20 The web card is attempting to reinitialize If this message appears for more than 2 minutes you may need to restart your browser connection or contact your network administrator for assistance AAA If further assistance is necessary visit Liebert com Pro gress Last updated Tuesday July 24 2007 02 37 05pm of update A E A AAA aes When the rebooting is complete the Web browser window returns to the de
54. ert IntelliSlot Web cards Liebert Nform will centrally manage alarm notifications to provide you with an easy interface to access criti cal system information A downloadable edition is available online at nform liebert com Liebert MultiLink Support The Liebert IntelliSlot Web card integrates with Liebert s MultiLink software to provide unattended graceful operating system shutdown of PCs servers and workstations The card can be monitored by MultiLink over the network eliminating the need for serial cables For more information on Multilink and a downloadable version of MultiLink software visit the Multilink page at multilink liebert com Liebert SiteScan Web With Modbus Support IS WEB485ADPT only The Liebert IntelliSlot Web 485 Card With Adapter integrates with Liebert s SiteScan Web software using Modbus to monitor trends for analysis and maintenance to ensure high availability operation of critical facilities For more information on SiteScan Web and Modbus integration visit the SiteScan Web page at sitescan liebert com Installation 2 0 INSTALLATION A WARNING Only a qualified service professional should install these products Liebert recommends having a Liebert Services representative perform the installation in large UPSs Contact Liebert Services at 1 800 LIEBERT 1 800 543 2378 2 1 Install a Liebert IntelliSlot Web Card Non Adapter Version Follow these steps to install a Liebert Intelli
55. ettings shown in Table A3 Table A3 Communication settings Pot Setinge z Baud Rate 9600 Bis per second 2600 Data Bits Bo Debs j zi settings gep bis F7 Stop Bits a Flow Conirol Restore Defaults 5 When the message at right appears in the HyperTerminal window press the Enter key A 2 2 LS Open the Terminal Emulation Interface TCP IP Connection To connect to the card using terminal emulation software with ZIZ an Ethernet connection to the Web card ORB new conecto 1 Open a terminal emulation application such as hev dranan ana ak xaza Name ea r HyperTerminal To do this e Click the Start button then Programs Accessories Communications and finally HyperTerminal 2 Inthe Connection Description window enter a name for the ES connection for example GXT2U then click OK a 3 Inthe Connect To window Ta ae e Choose TCP IP Winsock from the Connect Using Pam z3 drop down list TCPAP a Enter the IP address of the Web card for example Winsock Ta 192 168 0 125 in the Host Address box then click OK 4 When the message at right appears in the HyperTerminal window oes We Ge a ance Sey press the Enter key LU service Port Manager Active 5 Enter the Administrator username and password both are case lt Esc gt Ends Session sensitive a Login username default is Liebert TT TET b Password default is Liebert Password A2 A 2 3 Y
56. f the firmware update file Load Protected No Alarms Present Note The maximum length of the entry is 128 characters including sp E A A Save Configuration Categories ___Update Firmware _ Data Room UPS Server 192 168 015 TFTP Agent Info Factory Defaults Port 69 Firmware Update Web Filename OCWEBCARD_HID3_2 300 0_035780_AppFwUpdt bin TFTP IP Settings Management Protocol SNMP Access Traps Messaging Email SMS Customize ngs Message Reinitialize Reinitialize Telnet Users Reconnect to the Card 7 Click the Configure tab then TFTP and enter the username and password Steps 2 and 8 to return to the TFTP screen as shown above Begin the Upgrade Process 8 Open the TFTP application and start TFTP Ensure that all settings are ready to transfer the file including the location of the upgrade file Refer to your TFTP user manual for more details 9 Return to the Web interface 10 When ready to begin the download click the Update Firmware button amp EMERSON monitor control configure support Agent Information Network TFTP Firmware Download Data Room UPS Bldg 2 Floor 4 Parameter Description Supports Server02 Server IP address of the TFTP server 192 168 0 125 Port Port server is listening on typically 69 Device Status Filename Name of the firmware update file Load Protected No Alarms Present Note The maximum length of the
57. fault opening view The upgrade is now complete 10 xi OO Ta ms A fee A naw a We 4 f Emerson Network Power InteliSlot Web Card gt B dhe 0 gt EMERSON amp Liebert Network Power monitor control configure support Agent Information Summary Updated July 15 2007 05 51 28PM Uninitialized Uninitialized Uninitialized 192 168 0 125 Device Status Load Protected No Alarms Present may a E OUTPUT Monitor Categories iz 120 1 GXT 22 E Summary Active Alarms Battery Bypass Input Inverter Charge 100 Output Time Remaining 41 min Hardware Configuration Active Alarms Other No Alarms Present Check the new firmware version if you wish see A 3 2 Determine the Liebert IntelliSlot Card Type and Firmware Version UPDATING THE FIRMWARE XMODEM SERIAL METHOD Follow these steps to update the firmware using the Xmodem serial method This method works through the Web card s serial port employing terminal emulation software such as HyperTerminal NOTE This method includes a time sensitive operation requiring expeditious location of the upgrade files downloaded in A 3 3 Download the Firmware Upgrade File to the Computer Read through this entire section before beginning the upgrade A9 Updating the Firmware Xmodem Serial Method Connect a Cable to the Serial Ports 1 Figure A1 Open a Terminal Emulation Connection 2
58. ging Restores DHCP service the factory default replacing a static IP address or hostname 1f config ured during installation see 2 0 Installation 1 1 Reset to Factory Defaults Gy Terminal Emulation Serial or TCP IP Connection Telnet reos Men To restore the factory default settings Reset to Factory Defaults 2 Agent Card Information 1 Choose Factory Settings from the Main Menu then choose Reset _escs cancel menu level to Factory Defaults Reset to factory Defaults y n gt 2 Enter y yes at the prompt to confirm your choice To cancel enter n no 3 A message appears until the process is complete Resetting card to factory defaults Ey Web Interface To restore the factory default settings through the Web interface Please select a key gt e Click on the Configure tab then Factory Defaults in the left panel and finally Reset to Fac tory Defaults in the right panel Configure tab EMERSON monitor control configure event log Agent Information Factory Defaults SNMP_Test z SNMP _Test3 Parameter Description SNMP_Test4 Reset To Factory Clicking this button and confirming the actior 192 168 0 25 Defaults defaults Device Status Reset Load Protected No Alarms Present to Factory Defaults Factory foe Defaults Een ac j na kr Agent Information mi Factory Defaults 34 Factory Settings 7 2 Liebert DS Local Node Settings for Multiple Ca
59. hange the default password Table 15 Factory default passwords A A Administrator Full access to configuration and control functions as well as viewing privileges General User Username User Viewing privileges only no access to Password User configuration or control functions Follow these guidelines to change the user name and password Table 16 Username and password guidelines Maximum length 32 characters 6 or more characters recommended Valid characters Any printable character EXCEPT colon tab double quote question mark Upper lowercase Case sensitive letters must be uppercase or lowercase as entered Tips Avoid common names words and phrases as passwords En Terminal Emulation Serial or TCP IP Connection Telnet To change the Administrator or General user name or password 1 Choose IP Network Settings from the Main Menu then choose either e Change Administrator Username Password or Change General Username Password 2 Enter a user name the current user name is shown in brackets Enter Administrator Username press enter for Liebert Max 32 chars gt 3 Enter a password then verify by typing the password again Enter New Password Max 32 chars gt x x Verify Password gt 2 Web Interface To access usernames and passwords through the Web interface e Click on the Configure tab then Users in the left panel and finally Edit in the right panel After making cha
60. iagnosticTestFailed 1 3 6 1 2 1 33 1 6 3 19 upsAlarmOnBattery 1 3 6 1 2 1 33 1 6 3 2 upsAlarmShutdownPending 1 3 6 1 2 1 33 1 6 3 22 upsAlarmTestinProgress 1 3 6 1 2 1 33 1 6 3 24 upsAlarmLowBattery 1 3 6 1 2 1 33 1 6 3 3 upsAlarmTempBad 1 3 6 1 2 1 33 1 6 3 5 upsAlarminputBad 1 3 6 1 2 1 33 1 6 3 6 upsAlarmOutputBad 1 3 6 1 2 1 33 1 6 3 7 upsAlarmOutputOverload 1 3 6 1 2 1 33 1 6 3 8 upsAlarmOnBypass 1 3 6 1 2 1 33 1 6 3 9 IgpAgentDeviceCommunicationLost 1 3 6 1 4 1 476 1 42 2 3 0 1 IgpConditionOutputToLoadOff 1 3 6 1 4 1 476 1 42 3 2 1 102 Device Status Load Protected No Alarms Present Listing in right panel Events or Parameters Support IE Summary SNMP Capabilities p gt m Events Parameters 40 Introduction APPENDIX A FIRMWARE UPDATES A 1 A 1 1 A 1 2 INTRODUCTION Liebert s IntelliSlot cards may be updated to take advantage of the latest release of the firmware with enhanced features compatibility with new units or service patches Upgraded firmware may be downloaded with a browser such as Internet Explorer Liebert maintains firmware upgrades on its Web site www liebert com downloads Liebert manufactures various types of network cards for Liebert products Before beginning any upgrade determine the type of Liebert IntelliSlot card to be upgraded This identifying information the type of card and firmware version currently installed may be found in the documentation shippe
61. ically determined by 1 Content Certificate Certificate Import l 1 The import was successful The final Wizard window appears with a message that the process is complete Click Finish A confirmation box appears with a message that the import was successful Click OK 21 Network Settings 5 4 3 Install Security Certificates Internet Explorer 7 or later If you use Internet Explorer 7 or later and select HTTPS as the operation mode of the Web server see 5 4 1 Specify Web Server Settings follow these instructions to install a security certificate To do this Open Internet Explorer and enter https followed by the IP address or hostname of the Web card for example https 192 168 0 125 in the address bar The following message appears Certificate Error Navigation Blocked Windows Internet Explorer i 10 x Go X je https 192 168 0 125 4 x Google 2 File Edit View Favorites Tools Help we de Certificate Error Navigation Blocked TN M2 9 There is a problem with this website s security certificate The security certificate presented by this website was not issued by a trusted certificate authority Security certificate problems may indicate an attempt to fool you or intercept any data you send to the server We recommend that you close this webpage and do not continue to this website Click here to close this webpage
62. in the right panel The example below shows control operations for two Liebert units EMERSON W Liebert Network Power monitor control configure support Li b Agent Information Output Control e ert Data Room UPS Cc d Descripti Bldg 2 Floor 4 omman scription GXT2 U Supports Server02 Turn Output ON Click the button to take this action 192 168 0 125 Turn Output OFF Click the button to take this action Device Status Reboot Click the button to turn output OFF then back ON Load Protected No Alarms Present Note This is often useful to reset connected loads example Turn Output OFF after a delay of 0 seconds 0 to 300 Turn Output OFF co evya a Ak Turn Output ON after a delay of 0 seconds 0 to 300 Turn Output ON Abort Commands Turn Output OFF immediately then Turn Output ON after a delay of 10 seconds Reboot Alarm Silence Output 4am Statistics Tests EMERSON D Liebert monitor control configure Device Other Settings Device Identification Liebert Uninitialized z _ Uninitisized arameter l escription DS Uninitialized All The setpoints supported by your device are listed below Make the necessary changes and press 126 4 203 254 the Save button when finished example A ERD Device Status Note After pressing Save some setpoints may not update immediately depending upon your unit Unit Off type
63. ion Follow these steps to install a Liebert IntelliSlot Web 485 Card With Adapter P N IS WEB485ADPT e Locate the adapter mounting location in your Liebert equipment Secure the Liebert IntelliSlot Web 485 Card With Adapter with the supplied screws Connect the equipment s communication cable to the TB1 terminal block or P1 on the card see the user manual for the Liebert power or cooling unit for details e Connect a Modbus RS 485 cable to the TB2 terminal block Connect an input power supply cable to Pins 1 2 on the TB3 terminal block Pin 1 is at the far left and Pin 2 is the middle pin TB LL w ple rk _ gt 5 W o de e 7 GTO Bi E P3 NC P1 is on left gt ace PA dite We HH a end of terminal block la ea a a EK ah dy E Network Port for NMS ka emre Fema R ee Pe and Web Access Pris lino right sid Js IE SD Port of the terminal block a G a Hem a T o g ai ae Gee 6 Ee r is at the right side of EAS HA _ MAC Address the terminal block 2 2 1 Connect the Cable 1 Locate the blue serial configuration cable null modem that shipped with the card 2 Connect the configuration cable to the DB 9 port on the card and to a COM port on your PC 2 2 2 Prepare the Card for Configuration Table 3 Communication settings Baud Rate Data Bis 8 1 Use terminal emulation software such as HyperTerminal to open a direct connection to the car
64. ized characters Email Customize The text of the message sent to e mail recipients Choose from a list of items to Message include in the message For details see 6 3 Customize Messages SMTP Server The IP address or domain name of the SMTP e mail server that sends 32 messages characters Pot o SMTP server port typically the default port 25 TU Test Email After saving changes to e mail parameters send a test e mail message to verify the settings are correct The message status will be displayed ele Email Choose this option to display a log showing the results of test e mails BE 29 Messaging Ey Web Interface To access E Mail Configuration through the Web interface e Click on the Configure tab then Email in the left panel and finally Edit in the right panel After making changes click Save Configure tab EMERSON Liebert Network Power monitor control configure event log support Agent Information Messaging gt gt Email SNMP_Test SNMP_Test3 Parameter Description SNMP_Test4 mall From llSander lt A 192 168 0 25 Email From Senders email address ln most cases this will be the email address of the person to whom replies should be sent For Device Status example Support company com Load Protected No Alarms Present Email To Email address of the recipient Multiple email addresses should be separated by a semicolon Note The maximum length for an email address en
65. k Settings menu guide A E KK KK KK KK kk kK kk kk k kk 12 Table 9 Dootll l s ettingoS Kano ia ai lan hl l AM he alee ou do td daa don 13 Table 10 Domain Name Server settings 14 Table 11 Management protocol ranges 0 00 kK KK KK KK KK KK KK KK KK kk kk kk kk kk 15 Table 12 SNMP communications menu k ccsa KK KK KK KK KK KK KK KK KK kK kk kK kK kk kk 17 Tabl 15 Web Server SOL nO cia IA Plan yan b way al AA AAA v Ly al 19 Table 14 Time Server parameters 25 Table lo Factory detal pass Words oo yata Gnade hace AL Peake eae behead een eas Bees S0 Girka 26 Table 16 Username and password guidelines KK KK KK KK KK eee ee ee eee kK 26 Table le J Factory default passwords j k s k eee Roa hee SARA ee als A A eas 27 Table 18 Messagino men cuides is cstor ik AS aa sn ba nessa ewan chee hs 28 Fable 19 E malconho uration Uudessa bk aya KA ew X ala A SE AE a ee Kl es eee ot BS 29 Table 20 SMS conira on Pude abla aa eS a ANA be dl A Ba NAKA Ai A An g1 5 d40 040 Beas nb 31 Table 21 E mail and SMS message guldelines KK KK KK KK KK ee eee KK KK KK nee 32 Table 22 Factory default MAC addresses sS ii A AAA a l 35 Table 28 Control operations parameters functions vary by Liebert UNit o 3
66. key gt 30 Messaging Terminal Emulation Serial or TCP IP Connection Telnet To activate and set up SMS messages 1 Choose Messaging from the Main Menu then SMS Enable SMS y n gt 2 To enable the SMS feature enter y yes at the prompt 3 Choose SMS Configuration from the Messaging Menu then select an option and use the following guide to make changes Table 20 SMS configuration guide O Parameter sepan ima The e mail address of the sender for example support company com 64 characters typically the address where replies should be sent SMS Message Recipients The message will be sent to this list of addresses The SMS Text Message address is usually a 10 digit phone number followed by com where might be a company name To add an SMS address use the format 64 a 1112223333 abc com Multiple addresses must be added individually Changes may be made by entering d to delete an entry or e to edit an entry NOTE To specify multiple recipients of the SMS message in the Web interface use a semicolon to separate addresses in the SMS To box characters The subject line of the message By default this is the event description e g 120 SMS Customize Message AlarmOnBypass but it may be customized The text of the message sent to e mail recipients Choose from a list of items to include in the message For details see 6 3 Customize Messages characters SMTP Server The
67. l emulation or Telnet interface Open a Connection to the Card 1 Open a terminal emulation or Telnet connection to the Liebert IntelliSlot card Gf needed see instructions in A 2 2 Open the Terminal Emulation Interface TCP IP Connection or A 2 3 Open the Telnet Interface 2 Choose Firmware Updates from the Main Menu Eare Updates Menu 3 Choose TFTP Update from the Firmware Updates menu 77705 Tm shown at right Specify TFTP Server and Upgrade Filename 4 The TFTP Update Menu shown at right displays the TFTP ee ages O server s IP address and listening port along with the name Port 69 Filename uninitialized of the firmware update file Initiate TFTP Firmware Update 5 Select options as needed and refer to the following guide to change any settings lt ESC gt Cancel menu level Please select a key gt Table A4 Firmware update settings TFTP The IP address of the TFTP server for example 192 168 0 125 Pot Port that the TFTP server is using typically 69 Name of the firmware update file 128 characters maximum including spaces and punctuation Filename This is the file with the extension bin downloaded in A 3 3 Download the Firmware Upgrade File to the Computer 6 After making changes press the Escape key twice to return to the Main Menu 7 Choose Exit and Save to save your changes and reboot the card Reconnect to the Card 8 Connect to the Liebert IntelliSlot car
68. lly HyperTerminal 2 Inthe Connection Description window enter a name for the connection for example GXT2U then click OK Bor 3 In the Connect To window ap ye REM SERA e Choose TCP IP Winsock from the Connect Using Pinme FE drop down list TCP IP A _ Enter the IP address or hostname of the Web card for Winsock example 192 168 0 125 in the Host Address box then A HESIN click OK 4 When the message at right appears in the HyperTerminal window prea we OG 00 Te lner server press the Enter key Service Port Manager Active 5 Enter the Administrator username and password both are case lt Esc gt Ends Session sensitive a Login username default 1s Liebert per ee b Password default is Liebert Password NOTE For security change the default username and password see 5 7 Change Username Password 6 Inthe Main Menu enter the number that corresponds to your choice main menu Refer to 3 1 Guide to Configuration for details on each function i i System Information 7 After making changes return to the Main Menu and choose Exit and 2 vL settings Save to reboot the Web card and put your changes into effect see ee dea Cati ngs 3 6 Saving Changes and Reinitializing the Web Card Firmware Updates Quit and abort changes Exit and save Please select a key gt Configuration Overview 3 4 E Open the Telnet Interface To access configuration using Tel
69. me to an IP address Provide a host DNS Test only name a fully qualified domain name or an IP address click on Query for the card to attempt a lookup with the provided information Consult your network administrator for proper settings Secondary DNS Secondary IP address of the name server for network y Four numbers 0 255 separated by periods e g 192 168 0 1 14 Network Settings Ey Web Interface To access the DNS menu through the Web interface e Click on the Configure tab then Network Settings in the left panel and finally Edit beneath the table of parameters and descriptions After making changes click Save Configure tab O e EMERSON Liebert Network Power monitor control configure event log support Agent Information Network Settings gt gt Domain Name Server DNS SNMP_Test SNMP_Test3 Parameter Description SNMP_Test4 192 168 0 25 DNS Server ER Obtain DNS server Use DHCP BootP provided DNS server addresses Device Status addresses automatically LAA Note This option is only available when the network Boot Mode is either DHCP or No Alarms Present BootP Use the following DNS Manually enter DNS addresses server addresses Primary Domain Name Primary IP address of the name server for network which should be obtained from Server DNS your network administrator Configuration Categories Secondary Domain Name Secondary IP
70. mware Upgrade File to the Computer Then click Open to return to the update screen 6 When ready to begin the update click the Update Firmware button A screen will appear showing the firmware update progress NOTE Q Do not refresh your browser or open another browser window Wait until the firmware update has been completed before opening other applications or using the computer for other tasks 7 A message appears indicating whether the update was successful After the firmware update is completed the card will reinitialize and you may return to the Liebert IntelliSlot card s Web interface Check the new firmware version if you wish see A 3 2 Determine the Liebert IntelliSlot Card Type and Firmware Version A5 A 3 A 5 1 Updating the Firmware TFTP HyperTerminal Telnet Web Method UPDATING THE FIRMWARE TFTP HYPERTERMINAL TELNET WEB METHOD Follow these steps to update the firmware using the TFTP method This method is available through the terminal emulation Telnet and Web interfaces with an Ethernet connection to the Web card NOTE This method includes a time sensitive operation requiring expeditious location of the upgrade files downloaded in A 3 3 Download the Firmware Upgrade File to the Computer Read through this entire section before beginning the upgrade En LD TFTP Method Terminal Emulation Telnet Interface To update the Liebert IntelliSlot card firmware using the TFTP method with a termina
71. n Time Limit seconds 60 i B Consolidation Event Limit 30 1 Choose Messaging from the Main Menu then i j lt ESC gt Cancel menu level Email Configuration or SMS Please select a key gt Configuration 2 Choose Email or SMS Customize Message from the Configuration menu 3 Choose an option from the Email or SMS Customize Message Menu then enter y yes at the prompt to confirm your choice Repeat for each item to be included in messages Refer to the following guidelines to make changes Table 21 E mail and SMS message guidelines Parameter Parameter Description if enabled outgoing messages will include Definedin Def ned in d ka kak oF The IP Address or Hostname of the Web card 5 1 Boot IP Settings hostname Description of the SNMP event 9 0 Support Information Event Date amp Time Name Tre name for he Lebert unt 40 System Information The date amp time when the SNMP event occurred A clickable link to the Web card through the Web interface 5 1 Boot IP Settings Web Link amp Port 6 1 E Mail Configuration The port number of the SMTP server port 6 2 SMS Configuration Event Enable or disable consolidation of events for e mail SMS 6 1 E Mail Configuration Consolidation notification 6 2 SMS Configuration Consolidation Duration in seconds to consolidate events before sending a Time Limit aa aa eerie will be sent when this threshold is seconds reached regardless
72. neral User usernames and passwords to the factory defaults If you forget your username or password you may reset them using a serial configuration cable connection see Section 2 1 1 or 2 2 1 Connect the Cable which provides direct access to the card without a username or password To enter a new username and password see 5 7 Change Username Password Table 17 Factory default passwords A ee Administrator Full access to configuration and control functions as well as viewing privileges Username User Viewing privileges only no access to General User Password User configuration or control functions En IS Terminal Emulation Serial or TCP IP Connection Telnet To reset the usernames and passwords to the factory defaults 1 Choose IP Network Settings from the Main Menu then Reset Authentication to Factory Defaults Reset authentication to factory Defaults y n gt 2 Enter y to reset the Administrator and General User usernames and passwords to the default settings NOTE This feature is not available through the Web interface 27 Messaging 6 0 MESSAGING The Messaging menu is used to set up e mail and text message notifications Messaging Menu from the Web card l Email disabled j j j gt SMS disabled En LS Terminal Emulation Serial or TCP IP Connection Telnet Email Configuration SMS Configuration To access these options lt ESC gt Cancel menu level 1 Choose Messaging
73. net 1 Open a Telnet connection on a computer with an Ethernet connection to the Liebert unit To do this TT 2x Open a command prompt window click the Start button then y paesu of a program fds document or Run gen 7 of Enter cmd and click OK In the command prompt window that opens enter telnet followed by a space and the IP address or hostname of the Web card for example Penn Te On inet ae When the message at right appears in the command prompt window eres v2 96 00 Telnet server press the Enter key e a service Port Manager Active Enter the Administrator username and password both are case ESC Ends eee ron sensitive a Login username default is Liebert Login ebert b Password default is Liebert Password NOTE For security change the default username and password see 5 7 Change Username 4 5 Password In the Main Menu enter the number that corresponds to your choice main menu Refer to 3 1 Guide to Configuration for details on each function i System Information After making changes return to the Main Menu and choose Exit and 3 We UL DEDE A OS Save to reboot the Web card and put your changes into effect see Factory Settings Firmware Updates 3 6 Saving Changes and Reinitializing the Web Card Quit and abort changes Exit and save Please select a key gt 3 5 Ey Open the Web Interface To access configuration using the
74. nges click Save Configure tab EMERSON monitor control support Agent Information dea ED e tinct Data Room UPS Bldg 2 Floor 4 Parameter Supports Server02 Adminstrator Name and password for the user authorized t 192 168 0 125 Username Password control areas of the device interface card Description General User Name and password for the user to access tl Device Status Username Password interface card Load Protected No Alarms Present Password Notes Secret string known by the user Proper entr authorization ofthe user s access to the resp be composed of printable characters with the and question mark Configuration Categories Note The maximum number of characters all ll Data Room UPS a Agent Info CAUTION This string is case sensitive so be Factory Defaults case either small or capital letters It is reco m Firmware Update composed of six or more alphanumeric chara m Web be avoided for passwords m P Settings H Management Protocol ea Edit SNMP Ministrator Access w Traps Username Lie ert Messaging Email SMS General User Use rs a Customize Message Username User Reinitialize Password bes TT Telnet p m Users Password e Web http 192 168 0 125 config configUser htm JEN JEN EN HER JIR j 26 Network Settings 5 8 Reset Authentication to Factory Defaults You may reset the Administrator and Ge
75. ns as shown at right below Configure tab EMERSON monitor control configure support Agent Information Jie Pe eee aa lg Update the communication card firmware over the network Supports Server02 N d eree maintenance release A BEREY N YET NENN ZI Xi Device Status Protocol Options e rap Web Hyper Text Transport Protocol B rowse TFTP Trivial File Transport Protocol The server 192 168 0 125 at Administrator Password Required requires a username and password amp gt Warning This server is requesting that your username and Configuration Categories password be sent in an insecure manner basic authentication EMERSON Web li Data Room UPS without a secure connection m Agent Info Ea Factory Defaults m Firmware Update p a Web En IP Settings a IF Remember my password User name Web HTTP Firmware Update Description Name of the firmware update file Click the Browse button to navigate and select a valid firmware update file zz Parameter Filename Note The maximum length of the entry is 128 characters including spaces and punctuation Ce e Update Firmware Filename Browse Update Firmware Click this button to initiate the firmware update Connect To Filename Update Firmware 5 Click on the Browse button to locate the upgrade file T his is the file with the extension bin downloaded in A 3 3 Download the Fir
76. ns menu Parameter Description amp Telnet Menus Authentication Traps Enables authentication traps to receive security alerts when the Web card detects a request with an invalid community string Enables the RFC 1628 UPS specific information MIB on the Web card for RFC 1628 UPS MIB querying of information in that MIB This can be enabled or disabled independently of the Liebert Global Products MIB Traps This option enables the RFC 1628 traps to be sent when an alarm event occurs on p the device The parent option must be enabled for this to also be enabled Enables the Liebert Global Products MIB Enterprise Specific for querying of Liebert Global Products MIB information in that MIB This option can be enabled or disabled independently of the RFC 1628 MIB ve Enables event condition traps to be sent per the LGP MIB The parent option must ee aon ap be enabled for this to also be enabled l Enables system traps to be sent per the LGP MIB The parent option must be also WANA di A d la L enabled for this to be enabled Heartbeat Trap Interval Specifies how often a heartbeat trap will be sent to show that the device is online and functioning normally Display Modify Communities View devices that have permission to access the Web card identified by IP address or hostname read write permission and community string Up to 20 devices may be configured for access Communities Example write publicl write publicl A
77. nt Ethernet MAC Address 00 00 68 16 82 C1 GXT2 700RT120 GXT2MR10 0031300060AF011 O08NOVO0 Liebert com Item System Name Location Device Status Description Load Protected No Alarms Present Contact Manufacturer Support IE Summary l SNMP Capabilities Events in Parameters Agent App Firmware Label Agent Serial Number Device Model Device Firmware Version Device Serial Number Device Manufacture Date Manufacturer support 39 9 2 Events and Parameters Support Information You may view a list of all supported events and parameters for the Liebert equipment through any interface Depending on the Liebert IntelliSlot Web card the list might include SNMP and Modbus En Terminal Emulation Serial or TCP IP Connection Telnet To view this data e Choose IP Network Settings from the Main Menu e Choose Management Protocol then SNMP Communica tions e Choose Support Information from the SNMP Communica tions Menu to display the menu at right The menu displays the number of events the number of parameters the total number of objects sum of events and parameters e Choose Display Events to view a list of supported events for the Liebert unit as shown in the example at right These events may vary according to the Liebert unit where the card is installed e Choose Display Parameters to view a list of
78. onnection Telnet Interface along with a brief description of how to access the same function through the Web Interface Telnet NOTE The Terminal Emulation and Telnet interfaces present the same menus and choices Guide to Configuration Refer to the following guide for details on configuration functions Sections 3 4 to 3 5 describe how to get started with each interface Table 5 Guide to configuration details 3 Open the Web Interface SSC wo 3 6 Saving pill laa and Reinitializing the Web Card 3 2 Gp Open the Terminal Emulation Interface Serial Connection To access configuration using terminal emulation software with a serial connection to the Web card 1 2 3 4 Open a terminal emulation application such as HyperTerminal To do this e Click the Start button then Programs Accessories Communications and finally HyperTerminal In the Connection Description window enter a name for the connection for example GXT2U then click OK In the Connect To window e Choose COM3 from the Connect Using drop down list Click OK In the COM3 Properties window enter the communication settings shown in Table 6 Table 6 Communication settings Baud Rate 9600 Flow Control When the message at right appears in the HyperTerminal window press the Enter key In the Main Menu enter the number that corresponds to your choice Refer to 3 1 Guide to Configuration for details on
79. ower IntelliSlot Web Card Mozilla Firefox File Edit View History Bookmarks Tools Help e Coan Configure tab EMERSON monitor control configure event log support Agent Information Network Settings SNMP_Test SNMP_Test3 Parameter SNMP_Test4 c P 192 168 0 25 j Description Speed Duplex Speed and duplex configuration of the ethernet port Note Typically the value should be set to Auto che Device Status E o Load Protected Boot Mode Mode the card boots into in order to be a network re Sp omen eee Static Directly specifies the network parame DHCP Allows central management of networ BootP Older mechanism for central manager configuration Configuration Categories IP Address Network address for the interface ld SNMP_Test Agent Information Subnet Mask Network mask for the interface which divides your ne m Factory Defaults Default IP address of the gateway for network traffic destine im Firmware Update Gateway eo i The value should be obtained from your network ad r Netwo rk P Network Settings Acceptable values consists of 4 numbers ranging fr m DNS character As an example 10 0 0 1 Settings Tez adi s ll im Time SNTP Edit M t Protocol pi ajar n Speed Duplex B Access Boot Mode Static BootP DHCP m Traps Messaging IP Address m Email im SMS _ E Customize Message Default Gateway
80. rds If you use two cards of the same type with the Liebert DS you will need to change the local node set ting of one card These steps apply only when both cards are the same type either Two Liebert IntelliSlot Web cards P N IS WEBLBDS bare DS OT Factory Settings Menu Two Liebert IntelliSlot 485 cards P N IS 485LBDS 1 Advanced Communication Settings 2 Reset to Factory Defaults En LS Terminal Emulation Serial or TCP IP Connection Telnet PO Hewr Tava To access local node settings Please select a key gt Liebert DS Advanced Communication Settings 1 Choose Factory Settings from the Main Menu 2 Choose Advanced Communication Settings from the Factory Settings Menu Local Node Settings 3 Choose Local Node Settings from the Advanced a Communication Settings Menu ee eee Tevel 4 Choose Node 1 from the Local Node Settings Menu then use the please select a key gt following guide to make changes Liebert DS If there are two Liebert IntelliSlot Web cards or two Liebert Local Node settings Menu IntelliSlot 485 cards you must change the address of one card see Table 22 Communication Rate 38400 Maximum Master Address 3 For the Liebert IntelliSlot Web card the default address is 1 4 maximum Retry Count 5 For two Web cards set the address of the second card to 2 5 REET mid seo For the Liebert IntelliSlot 485 card the default address is 2 F90 nes menu Teve For two 485 card
81. re Control Allow configuration and control operations to be perf im TFIP a Network Settings im DNS im Test Refresh Interval _ Interval between automatic updates of the dynamic 1 im Time SNTP right panes containing parametric data and the devic im Management Protocol recommended values range between 20 and 60 sect im SNMP 10 and 600 seconds PERFORMANCE RECOMMENDATION Selection c M gt need for accurate status and parameter updates anc rm pene servicing these update requests If many web brows We b i SMS the entered value should be larger this will help ens Customize Message Edit a Reinitialize sa Telnet en m Users im Web HTTP Port HTTPS Port Password Protect Site enabled Configure Control enabled Refresh Interval seconds 19 Network Settings 5 4 2 Install Security Certificates Internet Explorer 6 or earlier If you use Internet Explorer 6 or an earlier version and select HTTPS as the operation mode of the Web server see 5 4 1 Specify Web Server Settings follow these instructions to install a security certificate Open Internet Explorer and enter https followed by the IP address or hostname of the Web card for example https 192 168 0 125 in the address bar The following message appears Information you exchange with this sile cannot be viewed or re changed by others However there is a problem with the site s security certificate is The secunty certifica
82. ription Supports Server02 Copyright Liebert Corporation 2000 2007 11 Network Settings 5 0 NETWORK SETTINGS The IP Network Settings Menu is used to enable network TP Network Settings Menu communications with the Web card Boot IP Settings Domain Name Server DNS Settings Management Protocol Web Server Telnet Server Time SNTP Change Administrator Username Password Change General Username Password Reset Authentication to Factory Defaults Refer to the following sections for detailed step by step instructions on each item from this menu Table 8 Network Settings menu guide Mentem LA 1 2 3 4 5 6 7 8 9 lt ESC gt Cancel menu level Please select a key gt 12 Network Settings 5 1 Boot lP Settings Boot IP Settings Menu The Boot IP Settings Menu is used to set parameters for network Speed Duplex access to the Web card Consult your network administrator for these 3 20 C mode LV E settings befault Gateway o 1e6 0L1 DNS Server 0 0 0 0 EN Q Terminal Emulation Serial or TCP IP Connection Telnet To change any parameter 1 Choose IP Network Settings from the Main Menu then Boot IP Settings 2 Select an option to change for example Speed Duplex then enter settings according to the following guide Table 9 Boot IP settings range Description amp Valid Settings Speed and duplex configuration of the Ethernet port e Auto default u
83. rom the Main Menu then Web Server 2 Select an option to change then use the following guide to make changes Table 13 Web server settings Parameter Description amp Valid Settings Select the operation mode of the Web server Web Server Disabled Web server is disabled Mode HTTP Standard Web port not encrypted e HTTPS Standard secure Web port all communication is encrypted Web Server listening port number For HTTP mode non encrypted communications the default port is 80 HTTP For HTTPS mode encrypted communications the default port is 443 Transport For HTTPS you must also install a security certificate for Internet Explorer Refer to the appro Port priate section for your version of Internet Explorer e 5 4 2 Install Security Certificates Internet Explorer 6 or earlier e 5 4 3 Install Security Certificates Internet Explorer 7 or later Password When enabled the entire site is password protected If disabled all pages are accessible Protect Site without a password except configure and control functions Enable or disable the use of a Web browser to perform configuration and control operations Note This feature affects configuration and control operations from the Web interface only If disabled these functions may still be available using other system interfaces Configuration Control The interval in seconds 10 to 600 seconds between automatic updates of dynamic Web pages parametric da
84. s set the address of the second card to 1 Table 22 Factory default MAC addresses Factory Default Set Node 1 Address Liebert IntelliSlot Card Part Number MAC Address of Second Card to Please select a key gt Liebert IntelliSlot Web Card LBDS IS WEBLBDS Liebert IntelliSlot 485 Card LBDS IS 485LBDS 35 Monitor and Control Functions Web Only 8 0 MONITOR AND CONTROL FUNCTIONS WEB ONLY Ey Web Interface Only The Web interface allows you to monitor and control the Liebert equipment where the Web card 1s installed in addition to configuration capabilities presented in previous sections 8 1 Monitoring Liebert Equipment To view monitoring data through the Web interface Open the Web interface if needed see 3 5 Open the Web Interface e Click on the Monitor tab if needed This is always the opening view after connecting to the Web interface as shown in the following example Monitor tab p Liebert monitor contr Agent Information Summary SNMP_Test SNMP_Test3 SNMP_Test4 192 168 0 25 Agent Information Device Status Device Status Load Protected No Alarms Present OUTPUT Monitor Categories ols Relig ots 120 1 V Bla GXT lii Summary a Active Alarms BATTERY Volts 54 9 V Monitor Categories ia Click to view in Mn N right panel Charge 100 Time Remaining 917 min Active Alarms No Alarm
85. s Present The top portion of the left panel displays information that appears on all pages Agent Information name contact location and description of the Liebert unit as defined in 4 0 System Information Device Status current status of the Liebert unit and whether any alarms are active if so the most recent alarm is listed e Monitor Categories appear at bottom left organized with folder icons and showing the avail able Monitoring functions e Click on a category to view parametric data in the right panel The example above shows a graphic representation of the current state of a Liebert UPS Other categories show data in table format The information will vary according to the type of Liebert unit NOTE If any alarms are currently active they are listed below the graphic in the opening window Click on the Active Alarms category to view more details about any alarms that are active 36 Monitor and Control Functions Web Only 8 2 Controlling Liebert Equipment To perform Control operations through the Web interface Open the Web interface if needed see 3 5 Open the Web Interface e Click on the Control tab as shown in the following example Emerson Network Power IntelliSlot Web Card Windows Internet Explorer xl Ge y http 192 168 0 125 9 X Google pl Bile Edit View Favorites Tool Help C O ntrol ta b e E Network Power IntelliSlot Web Card amp EMERSON
86. se this setting if unknown e 10Mbs Half Duplex e 100Mbs Half Duplex e 10Mbs Full Duplex e 100Mbs Full Duplex Startup mode enabling the Web card to be a network ready device Boot Mode Static Fixed network addresses and other parameters e DHCP Central management using dynamic network addresses e BootP Older mechanism for central management of network addresses IP address Network address for the Liebert unit Four numbers 0 255 separated by periods for example 10 0 0 5 lt ESC gt Cancel menu level Please select a key gt Speed Duplex Network mask that divides your network into manageable segments Four numbers 0 255 separated by periods e g 255 255 255 0 Hataule Gatewa IP address of the gateway for network traffic to other networks or subnets y Four numbers 0 255 separated by periods e g 10 0 0 1 Device on a network that assigns IP addresses that are not static HOMO DU Server Four numbers 0 255 separated by periods for example 192 168 0 5 DNS Server IP address of the Domain Name Server for the network Four numbers 0 255 separated by periods e g 10 0 0 1 Consult your network administrator for proper settings Ey Web Interface To access Boot IP Settings through the Web interface e Click on the Configure tab then Network Settings in the left panel and finally Edit beneath the table of parameters and descriptions After making changes click Save 8 Emerson Network P
87. string then press Enter Delete a device see example at right to enter parameters in one line Example Enter d then press Enter No confirmation message will appear d 2 Type the Entry Number then press Enter then press Enter NOTE Q Avoid the following setting it permits access by any host and may pose a security risk IP address 0 0 0 0 Access write Community public Display Modify Trap Communities View devices that are configured to receive notifications from the Web card identified by IP address or hostname trap listen port and community string Up to 20 devices may be configured to receive traps Trap Communities Example 10 0 0 5 publicl 10 0 0 6 publicl IP Port to Community address receive traps string Codes for lt a gt dd lt d gt elete lt e gt dit editing Complex lines allowed e g lt a 198 1 1 1 162 public gt gt Each device is identified by e Entry Number use the entry number 1 20 to edit or delete an entry IP address or hostname the address or name of the device to receive traps Multilink server Nform server Network Management System Port the Trap Listen Port where traps will be sent use 162 if the host computer uses standard ports 161 162 e Community string the community string used by the IP host for this Entry Number case sensitive up to 32 characters To make changes Add a device see example at right to enter all parameters in
88. t4 192 168 0 25 Device Status Load Protected No Alarms Present Configuration Categories E SNMP_Test Agent Information Factory Defaults Firmware Update Web TFTP Network Settings DNS Test Time SNTP Management Protocol SNMP Access Traps Messaging Email SMS Customize Message Reinitialize Telnet Users Web O Liebert monitor control configure event log support Management Protocol gt gt SNMP 2 Category Description Access Configure SNMP access parameters Traps Configure SNMP trap targets Parameter Description ee sSSSSS Authentication Trap If enabled a SNMP Authentication Trap will be sent to all trap targets Note Typically this feature is enabled as a security measure to alert a management station that unintended unauthorized requests are being received Heartbeat Trap Interval A periodic Heartbeat trap will be sent at the selected interval to the trap targets that have been configured to receive heart beat traps To select targets to receive heartbeat traps click click here Note Receipt of a heartbeat trap indicates the source device is operating properly and has the expected connectivity RFC 1628 MIB Enable or disable support for the retrieval of data from the RFC 1628 MIB objects RFC 1628 is an IETF proposed standard for UPS information Note For proper operation of Multi Linkand Nformthis feature must be enabled Enable or disable support
89. ta and device status in the right panel RECOMMENDATION Consider whether frequent updates will slow down the system If many users will access the device simultaneously select a larger value to best serve all users Recommended values range from 20 to 60 seconds Refresh Interval Ey Web Interface To access Web Server settings through the Web interface e Click on the Configure tab then Web in the left panel and finally Edit in the right panel After making changes click Save Configure tab EMERSON monitor control configure event log support Agent Information Web Configuration SNMP_Test SNMP_Test3 Parameter SNMP_Test4 192 168 0 25 ee Description Select the operation mode of the Web Server R o Disabled Web server is disabled Device Status o HTTP Standard web port not encrypted Load Protected o HTTPS Standard secure web port all comm No Alarms Present Port Web Server listening port number o Http 80 is the default for non encrypted com ___ gt Https 443 is the default for encrypted comm Configuration Categories lE SNMP_Test Password Protect When checked the entire site is password protectec Agent Information Site accessible without a password except the configure a Factory Defaults a Firmware Update m Web Note Checking this feature enables or disables con Web interface only Configuration and control may s interfaces Configu
90. te was issued by a company you have not chosen to trust View the certificate to determine whether you want to trust the certifying authority er The security certificate date is valid i The security certificate has a valid name matching the name Click on of the page vou are trying to view View Certificate Do vou want to proceed es Ho e Click the View Certificate button This opens the Certificate window View Certificate 2j xl 21x cea cora ifi m Certification path Certifi cate Certificate Information Allegro Root CA Pat h ta b Ez Liebert Monitoring Group This certificate cannot be verified up to a trusted Ez 192 168 0 125 certification authority Issued to 192 168 0 125 Issued by Liebert Monitoring Group Valid from 7 2 2007 to 3 27 2036 Certificate status This CA Root certificate is not trusted because it is not in the Trusted Root Certification Authorities store In the Certificate window above left click the Certificate Path tab In the Certificate Path tab above right click on Allegro Root CA then on View Certificate View Certificate Issuer Statement 20 Network Settings In the Certificate window click the Install Certificate button as shown below 21x General Details Certification Path Certificate Information This certificate is intended for the following purpose s Ensures the identity of a remote computer
91. the communication rate is 115200 This does not need to be changed Press Enter to continue Repeat Steps 12 through 15 within the 60 second limit to browse to the second upgrade file and download it to the Liebert IntelliSlot card Wait for the Progress window to close after the second file is downloaded Then repeat Steps 16 through 20 to download the third upgrade file This file is the largest and may take 30 minutes or longer to download A11 would You Like to Continue Y or N Firmware Update Step 2 3 1 Xmodemcrc 2 Xmodem1k Xx Ex1t Cancel Please select a key gt Current Communications Rate jis 115200 bps Press a number to Change Communications Rate 9600 bps 19200 bps 38400 bps 57600 bps 115200 bps Enter Accept Start Firmware Update Please select a key gt Press Enter to Start Firmware Update Updating the Firmware Xmodem Serial Method Complete the Upgrade and Restore Communication Rate 22 Choose 9600 bps from the menu shown below left 23 From the HyperTerminal menu click on Call then choose Disconnect this will not close the HyperTerminal connection to the card 24 In the HyperTerminal menu bar click on File then choose Properties 25 Click on the Connect To tab and click the Configure button This opens Port Settings tab in the COM1 Properties window as shown below right 26 Choose 9600 from the Bits Per Second drop down list and click OK then click
92. thority is Automatically m aI a confirmation of your identity and contains information Automatically select the certificate store based on the type of certificate used to protect data or to establish secure network select Place all certificates in the following store Gertificate store wi connections A certificate store is the system area where certificates are kept To continue dick Next e Click on Automatically select the certificate store based on the type of certificate then click Next Certificate Import Wizard xj Completing the Certificate Import Wizard You have successfully completed the Certificate Import wizard You have specified the following settings Certificate Store Selected Automatically determined by 1 Content Certificate Certificate Import l 1 The import was successful The final Wizard window appears with a message that the process is complete Click Finish A confirmation box appears with a message that the import was successful Click OK 23 5 5 Telnet Server Use the Telnet Server Menu to enable or disable access to the Web card through a Telnet interface En LD Terminal Emulation Serial or TCP IP Connection Telnet To change this setting 1 2 Choose Telnet Server then specify Enabled to permit Telnet access Disabled to block access via Telnet Ey Web Interface To access Telnet settings through the Web interface Ne
93. try is 64 characters Subject Subject of the email This value will default to the event description Configuration Categories E SNMP_Test The subject line is customizable Agent Information SMTP Fully qualified domain name or IP address of the server used for relaying email messages Factory Defaults Sew deyan Update Note 1 The maximum length for this entry is 32 characters e TFTP Note 2 If using a server name you must configure a DNS server under IP Settings Network Settings Port SMTP server port NTP Note Typically the default of 25 should be used me Management Protocol Test Clicking on this button will send a Test Email after new configuration changes have taken effect Em al SNMP Status of the email message will be displayed Access z Traps E d l t Messagin Uninitialized j P Email From SS SMS Customize Message Uninitialized Reinitialize Telnet Users Email To Web separate addresses with semicolons Event Subject Custom SMTP Server Uninitalized Port 25 Test 6 2 SMS Configuration SMS Configuration Menu Setting up event notifications for SMS text messages involves two U e __ steps enabling the function then specifying the parameters SMS Subject SMS Customize Message SMTP Server Uninitialized 25 Port Test SMS View Test SMS Log File lt ESC gt Cancel menu level Please select a
94. twork Settings Telnet Server Menu 1 Telnet Server enabled lt ESC gt Cancel menu level Please select a key gt Choose IP Network Settings from the Main Menu then Telnet Server e Click on the Configure tab then Telnet in the left panel and finally Edit in the right panel After making changes click Save Configure tab EMERSON monitor control configure event log support Agent Information SNMP_Test SNMP_Test3 SNMP_Test4 192 168 0 25 Telnet Configuration Parameter Description Telnet Server Enable or Disable the Telnet Server F Note This value is enabled to allow remote management evice Status Load Protected No Alarms Present Ea TelM t Server enabled Configuration Categories lE SNMP_Test n Agent Information a Factory Defaults m Firmware Update ma Web TFTP lm Network Settings m DNS Test Ea Time SNTP im Management Protocol SNMP mm Access m Traps lm Messaging im Email SMS a Customize Message m Reinitialize P Telnet Telnet m Users Web 5 6 Time SNTP Menu This permits setting time options how often the Web card synchronizes with the Time Server which Time Server to use for synchronization and which the Time Zone the Web card is operating in 24 1 SNTP Time Sync Rate 2 Time Server 3 Time Zone lt ESC gt Please select a key gt Edit Time Server Menu Hourly time nist gov GMT U
95. twork name for we j BI A ren tick usno navy m il dl Time eS a tock usno navy_mil Load Protected oa Server No Alarms Present time a nist gov list time b nist gov Synchronize Rate Rate at which time will be synchronized with the time server Device Time Zone ime zone where the device is located O Click on Edit ua Eat Save ent Information 5 to GER Factory Defaults Time Server time nistgov Mua options a Firmware Update Synchronize Rate Hourly O Daily ervers KANA m must be Ime one NEN sise add ente red GM T 1 2 00 International Date Line West manual ly GMT 11 00 Midway Island Samoa Time SNTP GMT 10 00 Hawaii Aleutian Time Management Protocol GMT 09 00 Alaskan Time GMT 06 00 Pacific Time US and Canada Tijuana GMT 07 00 Arizona l ae ae na pp Las is Ze Time zones saging GMT 07 00 Chihuahua La Paz Mazatlan Email GMT 06 00 Central America Time available SMS GMT 06 00 Central Time US and Canada from list GMT 06 00 Guadalajara Mexico City Monterrey GMT 06 00 Saskatchewan GMT 05 00 Bogota Lima Quito GMT 05 00 Eastern Time US and Canada GMT 05 00 Indiana East GMT 04 00 Atlantic Time Canada GMT 04 00 Caracas La Paz GMT 04 00 Santiago GMT 03 30 Newfoundland 25 Network Settings 5 7 Change Username Password The Web card is designed for two types of access each with a default user name and password For security be sure to c
96. y Edit in the right panel After making changes click Save Configure tab EMERSON i monitor control configure support Agent Information Agort nimet Data Room UPS Pa P Deserdon Bldg 2 Floor 4 arameter Description Supports Server02 Name Name to refer to the agent device Your system administrator may use a s 192 168 0 125 convention Device Status Note The maximum length of the entry is 255 characters including spaces ZEDE POTEET Contact Person responsible for maintenance and operation of the agent device whi No Alarms Present Ag e nt facility administrator or the vendor from whom you purchased the device Info Note The maximum length of the entry is 64 characters including spaces Location Description of the location of the agent device Configuration Categories i Uninitialized Note The maximum length of the entry is 64 characters including spaces Agent Info Description Other information useful for record keeping or quick reference Factory Defaults Firmware Update E Web Note The maximum length of the entry is 64 characters including spaces m TFTP maybe longer depending on the device mi IP Settings Note The values described above can be composed of printable character EH Management Protocol double quote m SNMP Access a am g Edit Email SMS Name Data Room UPS Customize Message Contact Reinitialize Telnet Users E Web Location Bldg2 Floor4 Desc