1. details The hood is supplied as a ducted version but may also be used in recirculation mode by inserting a charcoal filter Special accessories The air is ducted out through a pipe which is connected to the outlet hole A fig 1 by means of a coupling flange B To connect the hood to a wall box you use hoses and wall boxes as offered on the AEG price list as optional extras Extractor version Filter version Cooking vapours are cleaned by the charcoal filter Special accessories and ducted back into the kitchen The AEG original KF Plus charcoal filter is necessary for the recirculating mode see paragraph Special accessories For the recirculating mode proceed as follows a Remove the grid by turning knob A fig 2 b Position the filter fig 3 and rotate clockwise until it stops In this mode air will be expelled through an exhaust pipe with an internal diameter of 100 mm on the top of the cupboard c Replace the grid pres fr 4 WES VS Description of the appliance 1 Light switch 2 Motor switch 3 Work surface lamp 4 Grid IE Technical details Model 502 D Net weight 5 kg Height 145 mm Width 520 mm Depth 285 mm Absorbed power 160W Motor 1 x 120 W Lighting 1 x 40 Watt Lengt of the cable 110 cm Fan powers speed speed in compliance with DIN 44971 Speed 1 2 3 Extractor version 126 m
2. h 149 m h 185 m h Filter version 110 m h 133 m h 170 m h Flange 100 mm Fixing the hood After having adjusted the hood for the version required it may be installed This appliance is designed for fitting in a cabinet or some other support The opening to be made on the bottom of the wall hung cabinet must correspond with the measurements shown in fig 4 495 X 260 mm To fix the hood proceed as follows a remove the grid b Fit the hood into the opening c Secure the unit to the cabinet by screwing up screws through holes C fig 4 d Replace the grid The hood is fitted with one variable speed motor The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 5 15 minutes after having finished thus ensuring that all that cooking odours are eliminated Never leave a cooking hob or ring on without a pot or pan on top of it to avoid the possibility of excess heat damaging the unit Gas oil or coal cooker flames in particular should never be left uncovered Special care should be taken when using deep fat fryers since the oil in them can overheat and burst into flames The risk of fat catching fire is increased when using dirty oil It is extremely important to note that overheating can cause a fire Never carry out any flambe cooking under the hood Always disconnect the unit from the power supply before c
3. service You are welcome to telephone our technical assistance service see list of technical assistance centres whenever you need information or in the unlikely event of a fault When calling please be ready to specify 1 The model code number 2 The serial number E Nr 3 The manufacturing number F Nr This information is shown on the registration plate inside the unit behind the grease filter grille We reserve the right to change specifications and colours as a result of our policy of continuing technological development AEG Hausger te AG Postfach 1036 D 90327 N rnberg Copyright by AEG H 259 226 140 L 650A
4. supply If the appliance has been equipped with a mains lead with a moulded on type plug the following regulations must be comply with The plug moulded on to the lead incorporates a fuse For replacement use a5 amp BS1362 fuse Only ASTA approved or certified fuses should be used If the fuse cover carrier is lost a replacement cover carrie must be obtained from an electrical goods retailer If the socket outlets are not suitable for the plug fitted to the appliance then the plug must be cut off and destroyed for safety reasons and an appropriate plug be fitted When wiring the plug ensure that all strands of wire are securely retained in each terminal Do not forget to tighten the mains lead clamp on the plug Electrical connections 230 V using fixed power supply line with plug 240 V using fixed power supply line Great Britain Fuse rating 13 amps The unit should only be connected up by an authorized electrician See rating plate for further information It is recommended that the socket for the plug is sited above the cooker hood or above the overhead cabinet This has 2 advantages 1 The socket is not visible 2 The appliance can easily be unplugged when necessary If a fixed connection is required the cooker hood should be connected by an electrical installer registered with a competent electricity company An isolating device is to be provided on the fixed wiring side Switches with a contact opening of mor
5. 00 cm which is to say a larger hole could reduce the performance of the extractor hood If the hood is used in its filtering version carbon filter it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose minimum number of bends in the outlet hose Install hoses with an acute angle always following a gentle curve only hose as large as possible 100 mm Failure to observe these basic rules will drastically reduce the performance and increase the noise levels of the extractor hood When used as an extractor unit the hood must be fitted with a 100mm diameter hose If the fumes must be forced out through the wall you must obtain a MKZ sizable wall exhaust pipe with external exhaust and air intake E Nr 610 899 004 120 mm which is one of our optional parts When installing the hood make sure you respect the follow ing minimum distance from the top edge of the cooking hob ring surfaces electric cookers 650 mm gas cookers 700 mm coal and oil cookers 900 mm min Where flexible ducting is fitted the length should be no more than 3 metres with one 90 bend 2 metres with two 90 bends Bends of more than 90 will reduce the efficiency of the hood and reduce the air flow General
6. 502 D Extractor Hood Installation and Operating Instructions Contents Electrical connections uuuuunnuan0n0nnnnnnonnnnnnnnnnnnnnnnnnnnnnennn 4 Safety warnings for electricians 22220000ssssnnnnnennenneneennn 4 Appliances with 2 wires cc cccccsssecececeeseeesceeeeeesesseeeseaees 5 Safety warnings for kitchen unit installer 6 General deals emeini 7 Extractor version seen einher 7 lite ge VOR 2 9 eee eee ee ee 8 Description of the appliance uurusnnuannnnnnnnnnnnnnnnnnnnnnnnnnenn 9 Technical details un aan vested saveroneiencsens 9 Fixing the hood MIPFARESPPRBERSSEFENNEDEHNEREECFHREERFERERE EHEHEEFESSEREFHEREEFFPERER 10 Safeting warnings for user euueeeesssesnnnsnennnnnnnneeneennnnnnennnnnn 11 Hood operation ns uuseuciene ana 12 Care and maintenance n2u220nn0n0nnnonnnnn nn nnnnnnnnnnnnnnnnn 13 Metal grease filter cccccsececccesseeecceseeeceeeeeeeceeseeesseaeeess 13 Charcoal tler 14 Replacing the lamps ccccccccssseeeecesseeecceuseeeceeeeessseaeeees 15 TEAMING este re 15 Special accessories u2 uuu22nnana2nnnnnnnnnnnnnnnn ann nnnnnnnnnnnnnnnnnn 16 Technical ASSISTANCE service nununenennnnnnnnnannnnnnnnnnnnnn nenn 16 Safety warnings for electrician Electrical connections It must be ensured that the voltage and current indicated on the rating plate agree with the voltage ofthe userto electricity
7. arrying out any work on the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker It is very important to clean the hood and the grease filters at the recommended intervals Failure to do so could cause grease deposits to build up causing a fire hazard Safety warnings for user Controls Hood Operation The hood is fitted with a variable speed motor The most effective use ofthe hood is obtained by switching iton afew minutes before you start cooking and leaving iton afor approximately 15 minutes after you have finished thus ensuring all cooking odours are eliminated The control switches are located on the unit s front panel the light switch A switches the hood lamp on and off the motor switch B switches the cooking smoke and vapour extractor motor on and off enabling you to select one of the three different speeds Care and Maintenance Before performing any maintenance operation disconnect the hood from the electricity The hood has a metal grease filter Metal To clean the filter proceed as follows grease filter Open the grill by turning knob A fig 2 Pull the two plastic stops B as shown by the arrows fig 5 and remove the metal filter You should take out the metal filter every four weeks and wash it either in the dishwashing machine or by hand Clean the internal housing only with warm washing up water do not us
8. e any harsh cleaners brushes or abrasive Soak metal filter cassette for about one hour in hot water with a grease Hand washing loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Re fit the cassette when it is dry Place metal filter cassette in dishwasher Select most powerful Dishwashing washing program and highest temperature at least 65 C Repeat the machine process Re fit the cassette when it is dry When washing the metal grease filter in the dishwasher a slight discoloration of the filter can occur Charcoal filter The charcoal filter must be changed at least every 4 months The charcoal filter cannot be washed or regenerated The hood can only work well in the recirculating mode ifthe AEG recommended filter has been used the filter is changed as recommended in this section and if the hood is cleaned and maintained as instructed in this booklet Therefore follow the instructions closely for best performance The charcoal filter deals with odours which are created during cooking Pull the two plastic stops B as shown by the arrows fig 5 and remove the metal filter New charcoal filters are available from AEG or your retailer it must not be washed To remove rotate the filter in anticlockwise Fig 3 Re fit the metal filter 77 a So SAY we XE N SE III We ie Pe 4 J Attent
9. e than 3mm apply as isolating devices These include automatic cut out switches fuses and contactors VDE 0730 s 7 Part1 Electrical connection for the UK The appliance must be connected to fixed wiring with a double pole switched fused spur outlet with or without pilot lamp We strongly recommend the appliance to be connected only by a qualified electrician who is a member of the NICEIC who will comply with the IEE and any local regulations NOTE The terminology DOUBLE POLE means that both the live and the neutral supplies are switched and disconnected at the same time The terminations labelled SUPPLY are for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance IMPORTANT The wires of the mains lead supplied with this appliance are coloured in accordance with the following code Blue Neutral Brown Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the ter minals in the plug proceed as follows The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black BLUE BROWN NEUTRAL LIVE Appliances with 2 wires Safety warnings for kitchen unit installer When the unit is used in its extractor version a
10. ion Failure to observe the rules for cleaning the appliance and changing and cleaning the filters may cause fires Therefore we recommend you follow these instructions carefully Always turn off the electricity before replacing lamps 1 Remove the grid Fig 2 in order to check the lamps and replace them if necessary 2 Unscrew the lamps that do not work and replace them with 40W max lamps E14 If the light does not function check that the lamps are properly screwed before contacting a customers service centre Warning always disconnect the hood from the mains power supply before cleaning it Never insert pointed objects in the motor s protective grille Wash the outside surfaces using a mild detergent solution Never use caustic detergents or abrasive brushes or pow ders Only ever clean the switch panel and filter grille using adamp cloth and mild detergents It is extremely important to clean the unit and change the filters at the recommended intervals Failure to do so will cause grease deposits to build up that could constitute a fire hazard Attention Failure to observe the rules for cleaning the appliance and changing and cleaning the filters may cause fire Therefore properly observing these instructions is highly recommended Replacing the lamps Cleaning Special accessories See AEG price list for wallbox and hose accessories KF Plus charcoal filter E Nr 942 118 620 Technical assistance
11. sufficiently large ventilation hole must be provided with dimensions that are approximately the same as the outlet hole The air outlet must not be connected to chimney flues or combus tion gas ducts The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel burning appliances are installed It is advisable to apply for authorization from the relevant control ling authority when connecting the outlet to an unused chimney flue or combustion gas duct The air outlet installation must comply with the regulations laid down by the relevant authorities National and regional building regulations impose a number of restrictions on using hoods and fuel burning appliances con nected to a chimney such as coal or oil room heaters and gas fires in the same room The local decree on fuel burning systems specifies a maximum depression of 0 04 mbar in such rooms Hoods can only be used safely with appliances connected to a chimney if the room and or flat air environment combination is ventilated from outside using a suitable ventilation hole approxi mately 500 600 cm large to avoid the possibility of negative pressure being created during operation of the hood If you have any doubts contact the relevant controlling authority or building inspector s office Since the rule for rooms with out fuel burning appliances is air inlet should be same size as extractor outlet hole an aperture of 500 6

Download Pdf Manuals

image

Related Search

Related Contents

Scosche reNUE pro c2  Samsung SIR-T351 User's Manual  Betreibsanleitung Agria 6100 Cleanstar  Tucano One Premium  2-CH HD-SDI DISTRIBUTION AMPLIFIER USER MANUAL  1er mois  PDF:315KB  Massive Suspension light 40406/55/10  HP NC364T PCI Express Quad Port Gigabit Server Adapter User  introduction - Classic Accessories  