        Bunn AFPO-2 SL Water Dispenser User Manual
         Contents
1.                       49 i            dM            SOLENOID    2                   SWITCH  2                    SOLENOID  SWITCH  2       PUMP  SW ITCH  1 RED BLK            L YEL    BENE   3    BLK  1022                 1     e REDIBLK  oT            B             1 0 8             vio        4 10    230 VOLT      2 WIRE    SINGLE PHASE               5  3    BRN BLK    SW1C  ML    25         Dy    m mmi md    4    mI                                    5       GRN 12    ER    REFILL ON OFF    BRN BLK    REFILL ON OFF  SWITCH        nm    RED BLK    WHI    VACUUM  SWITCH  2    VACUUM  SWITCH  1    WHI    PROBE PROBE  CONTROL CONTROL  1 2    28791 011500    
2.     2  Separate the two halves of the pump and carefully  remove the tubing from within    3  Hold the new pump head as shown in Fig  24  with  rollers      the 2  6  and 10 o clock positions    4  Reinstall tubing in the new pump head by wrap   ping the tubing around the rollers as shown in Fig   24    5  Insert the slot of the tubing key  Supplied   as TUBING  shown in Fig  24  on the rotor so the bottom edge KEY  of the key is pressing the tubing into the pump    head cavity as shown in Fig  25    6  Hold the tubing and rotor in the pump head and  remove key carefully    7  Squeeze the pump body and pump heads together  simultaneously until pump body and pump head  are touching on all sides  Be careful not to pinch  the tubing between the pump body and the pump  head    8  Place the new pump body on the rotor shaft    9  Replace the four thumbscrews to secure the pump  to the motor assembly  Finger tighten only        FIG  24 TUBING START POSITION    FIG  25 TUBING LOADED    20 28791 040501    SERVICE  cont    VACUUM SWITCHES    If continuity is not present as described  the vacuum  switch is operating properly    If continuity is presentas described  withouta vacuum  generated by an empty product concentrate  replace       FIG  26 VACUUM SWITCHES    Location    The vacuum switches are located inside autofill  box  mounted on the left side of the solenoid mount   ing bracket just below the needle valves     the vacuum switch     Removal and Replacement        1   2     Dis
3.   FIG  19 SOLENOID  WATER  SWITCH  TERMINALS    17 28791 040501    SERVICE  cont    TEST OPERATE ON OFF SWITCH          FIG  20 TEST OPERATE SWITCH    Location  The test operate switch is located inside the autofill  box on the right side     Test Procedures    1  Disconnect the dispenser from the power source    2  Remove the black wire from the top center switch  terminal    3  Connect the dispenser to the power source  With  a voltmeter  check the voltage across the black  wire removed from the test operate switch and the  white wire from one of the solenoids  The indica   tion must be        BLK to Circuit  Board J4 3          a  120 volts ac for two wire 120 volt models   b  200 to 240 volts ac for two wire 200 or 240 volt  models       230 volts ac for two wire 230 volt models   5  Disconnect the dispenser from the power source     If voltage is present as described  proceed to  6   If voltage is not present as described  refer to the  Wiring Diagrams and check the wiring harness     6  Disconnect the wires from the left and center  terminals    7  Check for continuity across the left and center  terminals in rows one  two  three and four with the  switch in the  operate  position  Continuity should  not be present across the left and center terminals  with the switch in the  center  or  Test  position     If continuity is present as described  replacethe wires   The switch is operating properly    If continuity is not present as described  replace the  switch     Remov
4.   or other suitable water hose  to the  WATER INPUT       Ensure water regulator is set at 20 psi 137 9 kPa   Press the  TEST OUTPUT    switch and while water is flowing  from the test hose  check that the gauge reads 20    Place a one cup container under the test hose  Press the  TEST OUTPUT    switch  and carefully measure and  note the elapsed time from when water first flows form the test hose to when one cup of water has been  dispensed  Hoses and tubing should be primed and free of substantial air spaces and or bubbles prior to  calibration     4 28791 040501    MIX RATIO ADJUSTMENTS cont     6  Compare results with chart or formula below    7  Ifthe time observed is too short or long  turn the needle valve clockwise or counterclockwise  respectively      little at a time  Repeat from the preceding step until correct                                      Mix ratio  water flavor  Time for FLAVOR OUTPUT  1 2 cup  Time for WATER OUTPUT  1 cup   1 1 assume 20 sec  or obtain time per note below 40 sec  or 2 times flavor output time  2 1 assume 20 sec  or obtain time per note below 20 sec  or equal to flavor output time  3 1 assume 20 sec  or obtain time per note below 13 3 sec  or 0 67 times flavor output time  4 1 see below  assume 20 sec  or obtain time per note below 10 sec  or 0 5 times flavor output time  5 1 assume 20 sec  or obtain time per note below 8 sec  or 0 4 times flavor output time  6 1 assume 20 sec  or obtain time per note below 6 7 sec  or 0 33 times flavor 
5.  Hose 1  Cable 2 with Hosez2     etc     3 28791 040501    INITIAL SET UP  cont      5            f                     1             12     Connect one end of input hoses to the auto refill box and the other end to the product container  Product  container connectors  BIB  are not supplied  Install your own interface    Connect water line to auto refill box  A minimum of 20 psi  138 kPa  is required    NOTE  Make sure all connections are made before connecting the auto refill box to the power source    Each product container has an ON OFF refill switch located on the front of the auto refill box  A second switch  for each hopper is at the probe housing assembly  These are 3 position switches  high level  low level and a  center  OFF  position    Place the main ON OFF switch and ON OFF refill switches in the  OFF  position    Make sure all hoses are connected  Place the main ON OFF switch in the  ON  position       Place one of the ON OFF refill switches in the            position  after a four second delay product will begin to flow    through the hoses into the hopper  Be sure the switch selected is filling the correct hopper  if not  check the  labels  See NOTE in step 74       To test refill circuit short out probes on one of the hoppers with a screwdriver  so that hopper should shut off     Remove the screwdriver and the hopper will start to fill again after a four second delay  If hopper does not start  to fill  check labels  refer to NOTE in step 74   To change mix rat
6.  OTHERWISE  SHALL BE LIMITED  AS  SPECIFIED HEREIN  TO REPAIR OR  AT BUNN S SOLE OPTION  REPLACEMENT OR REFUND    In no event shall Bunn be liable for any other damage or loss  including  but not limited to  lost profits  lost sales   loss of use of equipment  claims of Buyer s customers  cost of capital  cost of down time  cost of substitute  equipment  facilities or services  or any other special  incidental or consequential damages     USER NOTICES  Carefully read and follow all notices on the equipment and in this manual  They were written for your protection   All notices are to be kept in good condition  Replace any unreadable or damaged labels     This equipment is to be installed to  comply with the Basic Plumbing Code of  the Building Officials and Code      DO        OVERLOAD CIRCUIT       ALWAYS ELECTRICALLY GROUND THE CHASSIS  OR ADAPTOR PLUG     DO        DEFORM PLUG OR CORD     FOLLOW NATIONAL AND LOCAL ELECTRICAL CODES     Administrators International  Inc   BOCA   and the Food Service Sanitation Manual  of the Food and Drug Administration  FDA        KEEP COMBUSTIBLES AWAY     FAILURE TO COMPLY RISKS EQUIPMENT  DAMAGE  FIRE  OR SHOCK HAZARD     READ THE ENTIRE OPERATING MANUAL    00656 0000 BEFORE USING THIS PRODUCT  00986 0002E 5 98    1994 Bunn O Matic Corporation    00986 0002    2 28791 051599       ELECTRICAL REQUIREMENTS   CAUTION   The dispenser must be disconnected from the power source until specified in  nitial Set Up    The 120 volt version of this 
7.  TERMINALS    28791 040501    SERVICE  cont   If continuity is present as described  reconnect the  REFILL SWITCHES    wires to the switch terminals    If continuity is not present as described  replace the   switch    Removal and Replacement    1  Remove the wires from the switch terminals    2  Compress the clips inside the autofill box and  gently push the switch through the opening in the  front of autofill box        Push the new switch into the opening and spread  the clips to hold switch in the autofill box    4  Referto Fig  15 when reconnecting the wires        Operate Switch  RED BLK to Vacuum  Switch  1       FIG  14 REFILL SWITCHES    Location    The refill switches are located on the upper right  front of the autofill box   2 AFPO 2  amp  3  Test Procedures    1  Disconnect the dispenser from the power source    2  Disconnect thetwo white red  brown black or red   black wires from the switch terminals        Connectthe dispenser to the power source  Check  for voltage across the white red  brown black or  red black wires from the test operate switch and  the white wire on solenoid Z2 or Z3  The indication  must be    a  120 volts ac for two wire 120 volt models     b  200 to 240 volts ac for two wire 200 or 240 volt WHI RED from Test    models  Operate Switch   c  230 volts ac for two wire 230 volt models  WHI RED to Vacuum  4  Disconnect the dispenser from the power source  Switch  3    BRN BLK from Test   Operate Switch    BRN BLK to Vacuum  Switch  2     3 AFP
8.  solenoid valve        6  Check the solenoid valve for coil action  Connect  the dispenser to the power source  Press the  solenoid  water  switch and listen carefully in the  vicinity of the solenoid valve for a  clicking  sound  as the coil magnet attracts    7  Disconnectthe dispenser from the power source     If the sound is heard as described and water will not  pass through the solenoid valve  there may be a  blockage in the water inlet before the solenoid valve or   the solenoid valve may require inspection for wear   and removal of waterborne particles    If the sound is not heard as described  rebuild or  replace the solenoid valve     Solenoid Valve Repair    1  Remove the wires from the solenoid valve to be  repaired    2  Turn off the water supply to the dispenser    3  Removethe nut securing solenoid valve coil to the  base    4  Remove guide  washer  o ring  plunger spring  and inspect for wear  Replace parts as required    5  Install new o ring in the solenoid valve base    6  Install plunger spring in the guide with spring to  the bottom of the guide    7  Install guide with the plunger spring into the sole   noid valve base    8  Install washer on guide    9  Install coil with retainer on guide and secure with  nut    10  Refer to Fig  17 and reconnect the wires        WHI from Main Harness  WHI to Solenoid  2     BLU from Solenoid  Switch  1    WHI to Solenoid  1       WHI to Pump  1  VIO from Solenoid  Switch  2    _ WHI VIO from  Solenoid Switch  3    WHI 
9. 00 to 240 volts ac for two wire 200 or 240 volt  models       230 volts ac for two wire 230 volt models   4  Disconnect dispenser from the power source     If voltage is present as described  replace the pump   If voltage is not present as described  refer to the  Wiring Diagrams and check main wiring harness     Pump Motor Removal and Replacement    NOTE  Do not disconnect or damage tubing  Tubing is  not replaced when pump is replaced    1  Disconnect the pump motor leads    2  Removethefourthumb screws securing the pump  head to the pump body    3  Remove the two 78 32 keps nuts securing the  pump motor bracket assembly to the refill unit    4  Remove the two 76 32 screws securing the pump  motor to its mounting bracket    5  Reattach this bracket to the new motor  and rein   stall the assembly in the refill unit    6  Reattach the pump head to the rear of the pump  motor with the four thumbscrews    7  Reconnectthe pump motor leads  Refer to Fig  23  to reconnect the wires           Pump Removal and Replacement    NOTE  Do not disconnect or damage tubing  Tubing is  not replaced when pump is replaced    1  Removethe fourthumb screws securing the pump  head to the pump body     WHI from Solenoid  2    S wae YEL from Pump Switch  1    Lig eA WHI from Pump  1     OORN from Pump Switch  2    We 2                    WHI from Solenoid  3     RED from Pump Switch  3    FIG  23 VACUUM SUPPLY PUMP TERMINALS       28791040501    SERVICE  cont    VACUUM SUPPLY PUMP TUBE INSTALLATION
10. 01    SERVICE  cont    PUMP  FLAVOR  ON OFF SWITCHES          P1521    FIG 12 PUMP  FLAVOR  START SWITCHES    Location    The pump  flavor  START switches are located on  the switch mounting plate inside the autofill box on the  right side        Test Procedure    1  Disconnect the dispenser from the power source    2  Disconnect the wires from the switch to be tested    3  Check for continuity across the terminals on the  switch when itis held in the on position  Continuity  must not be present across these terminals in the  released position     If continuity is present as described  reconnect the  wires to the switch    If continuity is not present as described  replace the  switch     Removal and Replacement   1  Disconnect the dispenser from the power source   2  Remove the wires from the switch terminals     3  Compress the clips inside the autofill box and  gently push the switch through the opening    4  Pushthe new switch into the opening and spread  the clips to hold switch in the autofill box    5  Referto Fig  13 when reconnecting the wires         1 AFPO 2  amp  3            BLK from Solenoid Switch 71  BLK to Test Operate Switch  RED BLK to Test Operate Switch  YEL to Pump  1     2 AFPO 2  amp  3    BLK from Solenoid Switch  1  BLK to Solenoid Switch  2  BRN BLK to Test Operate Switch  ORN to Pump  2     3 AFPO 3 ONLY    BLK from Solenoid Switch  2  BLK to Solenoid Switch  3  WHI RED to Test Operate Switch  RED to Pump  3    P1524    FIG  13 PUMP  FLAVOR  SWITCH
11. 2 1     6000 3000      3 4 3 4    3000 6000    AFPO 2 AFPO 3  FIG  9 SIGNAL CABLE PINS       6000                 1538       5  With the probe box switch in    LOW    position  check the resistance across the signal cable pins   see Fig  9    6  If readings match values indicated  the probe  system is functioning properly  If not  check the  probe boxes     Probe Boxes    1  Disconnect the signal cable from the probe boxes    2  Remove probe box from CDS hopper    3  Place the switch on the probe box in the    HIGH     position    4  Check the resistance across the box cable pins   see Fig  10         3000             2  amp  3        10                                    5       5  With the probe box switch in the    LOW    position  check the resistance across the pins  refer to Fig   10    6  If readings match the values indicated  the probe  system is functioning properly     Switch Removal and Replacement    1  Remove the  6 thread cutting screw securing the  probe housing cover to the probe housing    2  Remove the wires from the switch terminals    3  Compress the clips inside the probe box and  gently push the switch through the opening   4  Push the new switch into the opening and spread  the clips to hold switch in the autofill box    5  Refer to Fig  11 when reconnecting the wires            BLU  HIGH  from Probe  Box Cable         GRN  OFF  from Probe  Box Cable        TAN  LOW  from Probe Box   Cable   FIG  11 PROBE LOW OFF HIGH SWITCH  TERMINALS       28791 0405
12. AFPO 2  AFPO 2 SL  AFPO 3    AFPO 3 SL          OPERATING  amp  SERVICE MANUAL    BUNN O MATIC CORPORATION  POST OFFICE BOX 3227  SPRINGFIELD  ILLINOIS 62708 3227  PHONE   217  529 6601 FAX   217  529 6644    28791 0000   4 01   1998 Bunn O Matic Corporation www bunnomatic com    INTRODUCTION  This equipment supplies a liquid concentrate mixed with water at various ratios to the hoppers on the CDS 2 or  CDS 3 dispensers  It is for indoor use only on a sturdy counter or shelf     WARRANTY   Bunn O Matic Corp      Bunn     warrants the equipment manufactured by itto be commercially free from defects  in material and workmanship existing at the time of manufacture and appearing within one year from the date of  installation  In addition    1   Bunn warrants electronic circuit and or control boards to be commercially free from defects in material and  workmanship for two years from the date of installation    2   Bunn warrants the compressor on refrigeration equipment to be commercially free from defects in material  and workmanship for two years from the date of installation    3   Bunn warrants that the grinding burrs on coffee grinding equipment will grind coffee to meet original factory  screen sieve analysis for three years from date of installation or for 30 000 pounds of coffee  whichever comes first    This warranty does not apply to any equipment  component or part that was not manufactured by Bunn or that   in Bunn s judgement  has been affected by misuse  neglect  alte
13. O 3 ONLY       If voltage is present as described  proceed to  5    If voltage is not present as described  refer to the   Wiring Diagrams and check dispenser wiring harness  FIG  15 REFILL SWITCH TERMINALS   5  Check for continuity across the switch terminals  with the switch in the  ON  position  Continuity  must not be present when the switch is in the   OFF  position     15 28791 040501    SERVICE  cont    SOLENOIDS       FIG  16 SOLENOIDS    Location   The solenoids are located inside the autofill box     Test Procedure    1  Disconnect the dispenser from the power source    2  Disconnect the white violet  violet or blue wire and  the white wire from the solenoid    3  Connectthe dispenser to the power source  Press  the solenoid  water  switch  and with a voltmeter   check the voltage between the white wire  and  either the blue  violet  or white violet wire  The  indication must be    a  120 volts ac for two wire 120 volt models   b  200 to 240 volts ac for two wire 200 or 240 volt  models   C  230 volts ac for two wire 230 volt models   4  Disconnect the dispenser from the power source     If voltage is present as described  proceed to 75   If voltage is not present as described  refer to the  Wiring Diagrams and check dispenser wiring harness     5  Checkfor continuity across the solenoid valve coil  terminals     If continuity is present as described  refer to Fig  17  and reconnect the wires to the solenoid    If continuity is not present as described  replace the 
14. Refer to Service   Solenoids for test  procedures  See page 16    The thermal switch will reset  but  requires up to 30 minutes of cooling  time  See NOTE below    NOTE  This refill unit should not be used to initially fill the hopper  Running the motor for extended periods will  trip the thermal switch  The thermal switch will reset  but requires up to 30 minutes of cooling time     28791 040501    SERVICE    This section provides procedures for testing and  replacing various major components used in this  dispenser should service become necessary  Refer to  Troubleshooting for assistance in determining the  cause of any problem     WARNING   Inspection  testing  and repair of electri   cal equipment should be performed only by qualified  service personnel  The dispenser should be un   plugged when servicing  except when electrical tests  are required and the test procedure specifically states  to plug in the dispenser     COMPONENT ACCESS    WARNING   Disconnect the dispenser from the power  source before the removal of any panel or the replace   ment of any component     All components are accessible by removing the  eight  8 32 screws  five on the front and three on the  rear  securing the main housing to the main mount   ing panel and the removal of the four  8 32 nuts se   curing the pump solenoid switch panel to the sole   noid mounting bracket  Refer to Fig  1    Refer to the contents listing for component loca   tion     Contents                                     D
15. al and Replacement    1  Disconnect the dispenser from the power source    2  Remove the wires from the switch terminals    3  Compresstheclips inside onthe backofthe switch  panel and gently push the switch through the  opening    4  Pushthe new switch into the opening and spread  the clips to hold the switch in the switch panel    5  Referto       21 when reconnecting the wires        BLK from Main  ON OFF Switch                BLU from Solenoid Switch 71          VIO from Solenoid Switch  2 1                     WHI VIO from Solenoid Switch  3          gt                   RED BLK from Pump Switch  1    RED BLK to Refill Switch  1   BRN BLK from Pump Switch  2             BRN BLK to Refill Switch  2       WHI RED from Pump Switch  3                         _   WHI RED to Refill Switch  3       FIG  21 TEST OPERATE SWITCH TERMINALS       28791 040501    SERVICE  cont    VACUUM SUPPLY PUMP ASSEMBLY       21    P15  FIG  22 VACUUM SUPPLY PUMP ASSEMBLY  Location   The vacuum supply pumps are located inside the  autofill box     Test Procedure    1  Disconnect the dispenser from the power source    2  Disconnect the white wire from the pump lead and  the yellow  orange or red wire from the other lead    3  Connect the dispenser to the power source  With  a voltmeter  check the voltage across the white  wire and yellow  orange or red wire  Push the  pump  flavor  switch for the pump to be tested   The indication must be         a  120 volts ac for two wire 120 volt models   b  2
16. ce the fuse     Removal and Replacement    Fuse    1  Remove the cap from the fuse holder    2  Remove fuse from the fuse holder and inspect  If  blown  discard    3  Install new 10 amp fuse in the fuse holder    4  Reinstall fuse holder cap     Fuse Holder    1  Disconnect the dispenser from the power source    2  Disconnect the wires from the rear of the fuse  holder    3  Remove the nut securing the fuse holder to the  front of the main mounting panel    4  Pushthefuse holder through the hole in the panel    5  Install new fuse holder and fuse through the hole  in the panel    6  Secure the fuse holder to the panel    7  Referto Fig  5 and reconnect the wires           BLK from Main  Wiring Harness        BLK to Main  ON OFF Switch    G  5 FUSE HOLDER TERMINALS        P1331       F    28791 040501    SERVICE  cont    MAIN ON OFF SWITCH       FIG  6 MAIN ON OFF SWITCH    Location    The main ON OFF switch is located on the lower  right front of the autofill box just above the power  cord        Test Procedure    1  Disconnect the dispenser from the power source    2  Disconnect the black wire from the fuse holder  and the white wire from pump  1        Connect the dispenser to the power source  Check  for voltage across the black wire removed from the  switch and the white wire removed from pump  1   The indication must be    a  120 volts ac for 2 wire 120 volt models   b  200 to 240 volts ac for two wire 200 or 240 volt  models       230 volts ac for two wire 230 volt mode
17. connect dispenser from the power source   Removal of the two  8 32 keps nuts securing the  pump motor assembly nearest the vacuum  switches is required to access the lower vacuum  switch   Disconnectthe inputtubes from the vacuum switch  to be replaced    Disconnect the wires on the vacuum switch to be  removed    Remove the two 4 40 screws securing the vacuum  switch to the solenoid bracket  Remove and dis   card switch    Using two  4 40 screws secure the new vacuum  switch to the solenoid bracket     7  Refer to Fig  27 and reconnect the wires   Test Procedure    8  Connect the inputtubes to the new vacuum switch   1  Disconnect the dispenser from the power source  9  Restore the pump motor assembly to its normal    2  Disconnect flavor input lines    3  Disconnect white red  red black or the brown   black wires on the vacuum switch    4  Check for continuity across the switch leads     mounting position using the two  8 32 keps nuts     ON WHI RED from Refill ON OFF Switch  3    MESE WHI RED to Circuit Board J4 2    o     ____    RED BLK from Refill ON OFF Switch  1    RED BLK to Circuit Board J4 5        lt  gt  BRN BLK from Refill ON OFF Switch  2           BRN BLK to Circuit Board J4 4       FIG  27 VACUUM SWITCH TERMINALS    28791 040501    PIPING DIAGRAM  AFPO 2     The only difference between the AFPO 2 3 and AFPO 2 3 SL is the SL models have a water output line and  a flavor output line for each product  This allows the water and flavor to be mixed in the CDS hoppe
18. ct the Bunn O Matic  Technical Service Department     Inspection  testing  and repair of electrical equipment should be performed only by qualified service personnel   All electronic components have 120 volt ac and low voltage dc potential on their terminals  Shorting of  terminals or the application of external voltages may result in board failure    Intermittent operation of electronic circuit boards is unlikely  Board failure will normally be permanent  If an  intermittent condition is encountered  the cause will likely be a switch contact or a loose connection at a  terminal or crimp    Solenoid removal requires interrupting the water supply to the valve  Damage may result if solenoids are  energized for more than ten minutes without a supply of water    The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened  This will help  to avoid twists and kinks in the tubing    Make certain that all plumbing connections are sealed and electrical connections tight and isolated    Keep away from combustibles     WARNING     Exercise extreme caution when servicing electrical equipment     e Unplug the dispenser when servicing  except when electrical tests are specified     Follow recommended service procedures    Replace all protective shields or safety notices    PROBLEM PROBABLE CAUSE REMEDY    Product will not dispense 1  No water Water lines and valves to the dis     penser must be open     2  No power or incorrect voltage to    1  Check the out
19. dispenser has an attached cordset and requires 2 wire  grounded service rated 120  volts ac  15 amp  single phase  60 Hz  The mating connector must be a NEMA 5 15R     The 230 volt CE version requires 2 wire  grounded service rated 230V ac  single phase  50 Hz     The 200 volt or 240 volt versions require 2 wire  grounded service rated 200 volts ac or 240 volts ac  single  phase  50 Hz    Refer to the dispenser s data plate for exact voltage requirement      Electrical Hook Up   CAUTION   Improper electrical installation will damage electronic components    1  An electrician must provide electrical service as specified    2  Using a voltmeter  check the voltage and color coding of each conductor at the electrical source       Connect the dispenser to the power source     PLUMBING REQUIREMENTS   This dispenser must be connected to a cold water system with operating pressure between 20 and 90  138  and 620 kPa  psi from         or larger supply line  A shut off valve should be installed in the line before the  dispenser  Install a regulator in the line when pressure is greater than 90 psi  620 kPa  to reduce it to 50 psi  345  kPa   The water inlet fitting is 74  flare   NOTE   Bunn O Matic recommends 1   4  copper tubing for installations of less than 25 feet and    for more than  25 feet from the     water supply line  At least 18 inches of an FDA approved flexible beverage tubing  such as  reinforced braided polyethylene or silicone  before the brewer will facilitate movemen
20. io refer to MIX RATIO ADJUSTMENTS     CLEANING  RECOMMENDED WEEKLY CLEANING     This should be done in conjunction with the recommended weekly cleaning of your CDS 2 or CDS 3 machine  The  CDS Hoppers must be empty before starting   1  Preparea 1 gallon cleaning solution consisting of 1 gallon of hot water and a sanitizing cleaner which contains    3 5  chlorine based sanitizer  Mix per manufacturers instructions   Remove connectors from each concentrate container and place them directly into the cleaning solution   Energize each refill station and allow the cleaning solution to pump through the system into the hoppers  The  cleaning procedure should remove the color stains from the tubing  If not  prepare another gallon of cleaning  solution and repeat    After the cleaning solution has been pumped into the hoppers  rinse the cleaning solution container with hot  water    Fill the cleaning solution container with hot water  Energize each refill station and rinsethoroughly  The amount  of clean hot rinse water should equal the amount of cleaning solution pumped through the system    Empty the hoppers of your CDS machine and follow the recommended cleaning instructions    NOTE  The hoses should be checked monthly for deterioration  cracks and possible discoloration from some  concentrates  Replace the tubing when necessary     MIX RATIO ADJUSTMENTS    Tto    Remove the top access panel    Connect the test hose to the  WATER OUTPUT    to be adjusted    Connect the provided hose
21. let for 120 volts  the dispenser on two wire 120 volt dispensers    A2  Check the outlet for 200 volts  or 240 volts ac for two wire 200  volt or 240 volt dispensers    A3  Check the outlet for 230 volts  on two wire 230 volt dispensers      B  Check circuit breakers orfuses     3  Signal cable unplugged Signal cable must be plugged in    4  Hopper is full Product must not be touching  probes to fill    5  Fuse and fuse holder Refer to Service   Fuse and Fuse  Holder for test procedures  See  page 11    7 28791 040501    TROUBLESHOOTING  cont    PROBLEM    Product will not dispense  cont      Incorrect mix ratio    Motor thermal cutout  motor stops  running     PROBABLE CAUSE    6  Main ON OFF switch    7  Probe box LOW OFF HIGH  switches  8  Circuit board    9  Vacuum switch    10  Vacuum Supply pump    11  Pump  flavor  start switches    1  No water    2  Needle valve    3  Solenoids    1  Motor overheat    REMEDY    Refer to Service   Main ON OFF  Switch for testing procedure  See  page 12    Refer to Service  Probe system  See  page 13    Refer to Service   Circuit Board for  testing procedures  See page 10    Refer to Service   Vacuum switch for  testing procedures  See page 21    Refer to Service   Vacuum Supply  pump for testing procedures  See  page 19    Referto Service  Pump  flavor  start  switches for test procedures  See  page 14    Water lines and valves to the dis   penser must be open     Refer to Setup   Mix Ratio Adjust   ments for adjustment  See page 4    
22. ls   4  Disconnect the dispenser from the power source     If voltage is present as described  proceed to  5    If voltage is not present as described  refer to the  Wiring Diagrams and check the dispenser wiring har   ness        5  Check for continuity across the switch terminals  with the switch in the  ON  position  Continuity  must not be present when the switch is in the   OFF  position     If continuity is present as described  reconnect the  wires to the switch terminals    If continuity is not present as described  replace the  switch     Removal and Replacement    1  Remove the wires from the switch terminals    2  Compress the clips inside the autofill box and  gently push the switch through the opening       Push the new switch into the opening and spread   the clips to hold switch in the autofill box    Refer to Fig  7 when reconnecting the wires         m    BLK from Fuse Holder       BLK to Solenoid  Water   Switch  2 AFPO 2  amp  3    FIG  7 MAIN ON OFF SWITCH TERMINALS    28791 040501    SERVICE  cont    PROBE SYSTEM       FIG  8 PROBE SWITCHES    Location  The probe switches are located on the rear of each  hopper  mounted in the probe housing cover     Test Procedure   Probe System   1  Disconnect the dispenser from the power source    2  With the probe boxes connected to the signal  cable  remove connector from refill box    3  Place the switch on the probe box in the    HIGH     position    4  Check resistance across pins as shown in Fig  9             1 
23. ould be adjusted to dispense 1 cup of water in 10 seconds   NOTE  Hoses and tubing should be primed and free of substantial air spaces and or bubbles prior  to calibration        NEEDLE VALVE    5 28791 040501    OPERATING CONTROLS       A  MAIN POWER ON OFF  The main power ON OFF switch is located on the right of the front panel just above the power cord     B  REFILL CIRCUIT ON OFF  The refill circuit ON OFF switches are located on the right of the front panel just above the main power switch   These allow each circuit to operate independently     C  TEST OPERATE   The TEST OPERATE switch is located inside the auto   fill box just below the top access cover  For setting flow  rates and mix ratios for flavors  place the TEST OPER   ATE switch in the  TEST  position  This allows the op   erator to run the water and flavor lines for each circuit  depending on the requirements for the flavor recipe     D  PROBE CONTROL BOX LOW OFF HIGH   On models equipped with a dual level probe  there is a  LOW OFF HIGH switch located at the probe control box  on the hopper  The  OFF  position allows the operator  to disable the probe for that hopper only  THE  LOW   and  HIGH  positions allow the operator to select the  level of product desired for that hopper        6 28791 040501    TROUBLESHOOTING  A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems    encountered  If the problem remains after exhausting the troubleshooting steps  conta
24. output time       NOTE  For a typical adjustment  the time for flavor output in the center column above is assumed to be 20  seconds  A more specific flavor pump output time may be obtained prior to adjustment of the needle valve   To do so  connect the flavor to be tested to the    FLAVOR INPUT     and the test hose to the corresponding     FLAVOR OUTPUT     make no connection to the    WATER INPUT      With a one cup container under the test  hose press the corresponding    TEST OUTPUT    switch  and carefully measure and note the elapsed time from  when the product first flows from the test hose to when one half cup of the product has been dispensed  This  value may then be used in the formula below  Following flavor pump output measurement  disconnect the  flavor line from the    FLAVOR INPUT    and purge remaining product from the line     Formula for setting mix ratio  To obtain the time for dispensing 1 cup of water  divide the time it  takes to dispense one half cup of product by the first number in the mix ratio and then multiply the  result by two   Example  W 2 F X  Where W is the time it should take to dispense one cup of water  it took F  seconds  20 here  to dispense 1 2 cup of flavor concentrate  we desire a mix ratio X of 4 1  X will  be the first number in the mix ratio  4    Therefore  W   2  20 4    W   2 5   W   10 seconds    50 if it took 20 seconds to dispense one half cup of flavor concentrate  and a mix ratio of 4 to 1  is required  the needle valve sh
25. ration  improper installation or operation  improper  maintenance or repair  damage or casualty    THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY  WRITTEN OR  ORAL  EXPRESS OR IMPLIED  INCLUDING  BUT NOT LIMITED TO  ANY IMPLIED WARRANTY OF EITHER  MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE  The agents  dealers or employees of Bunn are  not authorized to make modifications to this warranty or to make additional warranties that are binding on Bunn   Accordingly  statements by such individuals  whether oral or written  do not constitute warranties and should not  be relied upon    The Buyer shall give Bunn prompt notice of any claim to be made under this warranty by telephone at  217   529 6601 or by writing to Post Office Box 3227  Springfield  Illinois  62708 3227  If requested by Bunn  the Buyer  shall ship the defective equipment prepaid to an authorized Bunn service location  If Bunn determines  in its sole  discretion  that the equipment does not conform to the warranty  Bunn shall repair the equipment with no charge  for parts during the warranty period and no charge for labor by a Bunn Authorized Service Representative during  the warranty period  If Bunn determines that repair is not feasible  Bunn shall  at its sole option  replace the  equipment or refund the purchase price for the equipment    THE BUYER S REMEDY AGAINST BUNN FOR THE BREACH OF ANY OBLIGATION ARISING OUT OF THE SALE  OF THIS EQUIPMENT  WHETHER DERIVED FROM WARRANTY OR
26. rs  Refer to    the illustration below when connecting the lines                          28791 011500    22    SCHEMATIC WIRING DIAGRAM    AFPO 2    L1    BLK        MAIN ON OFF  SWITCH  1     i BLK          en 10            BRN BLK  SWIC               PUMP    SWITCH  2                 mm    ORN       ep    SOLENOID  SWITCH   2    d     PUMP  SW ITCH  1    RED BLK          pA Cy     EE        ie    BLK                       1 qe REDIBLK  nT sle  e         0 8                          J440             4 3    120 VOLT AC 2 WIRE    SINGLE PHASE       23          mud    mm                          Dy    e ec     mmm                    M M     Kee                    4                  GRN     l    REFILL ON OFF    REFILL ON OFF  SWITCH      mm    VACUUM  SWITCH   2    VACUUM  SWITCH   1    PROBE  CONTROL  1    BRN BLK    RED BLK    WHI    WHI    PROBE  CONTROL  2    28791 051599    SCHEMATIC WIRING DIAGRAM    L1    BLK                MAIN ON OFF  SWITCH 000002           Ti  if    AMP                  WHI RED    120 VOLT AC 2 WIRE  SINGLE PHASE        3 WHI  BRN BLK                3    WHI RED    SW1D  DU     BRN BLK    Meg    RED BLK    24    B          GRN N                 REFILL ON OFF       SWITCH  3  T    WHI RED   REFILL ON OFF  T SWITCH  2  E    n BRN BLK          y  T     0  P  E  R    REFILL ON OFF  E  RED BLK  5  Ww      H  C  H    VACUUM    VACUUM    CONTROL CONTROL CONTROL    28791 051599    SCHEMATIC WIRING DIAGRAM  AFPOA 2    L1    BLK                  MAIN ON OFF  
27. t to clean the countertop   Tubing is supplied by Bunn O Matic  part number 00326 0000   Bunn O Matic does not recommend the use of  a saddle valve to install the brewer  The size and shape of the hole made in the supply line by this type of device  may restrict water flow    This equipment must be installed to comply with the Basic Plumbing Code of the Building    Officials and Code Administrators International  Inc   BOCA  and the Food Service Sanita   tion Manual of the Food and Drug Administration  FDA         INITIAL SET UP  NOTE  This refill unit should not be used to initially fill the hopper  Running the motor for extended periods will  trip the thermal switch  The thermal switch will reset  but requires up to 30 minutes of cooling time     NOTE  Hoses and product container connectors are not supplied  Fitting  clamps and labels are supplied  Make  hose assemblies as required  Refer to P PING DIAGRAM on page 22     1  Assemble hoppers with probe housing assemblies to CDS 2  CDS 3 or modify existing hoppers using template  provided    2  Make sure probe housing assembly is pushed down into slots on back of hoppers        Install cable assembly to the lower right front of the auto refill box and the probe housing assemblies on the  hoppers  The connectors on the cable pushes in and cap rotates 1 4 turn to lock into position    4  Run output tubes from auto refill box to the quick disconnects in the hoppers     NOTE  Make sure numbers on the labels match up  Cable 1 with
28. tm            10  Fuse  amp  Fuse                                                            11  Main ON OFF                             12  Probe LOW OFF HIGH Switches                             13  Pump  Flavor  Start Switches                                 14  Refill ON OFF Switches                                          15  sr M                       16  Solenoid  Water  Start Switches                             17  Test Operate                          tts 18  Vacuum Supply Pump Assembly                            19  Vacuum SWINGS  PR 21                           22    Wiring Diagrams               iege 23    FIG  1 COMPONENT ACCESS       28791 040501    SERVICE  CIRCUIT BOARD    FIG  2 CIRCUIT BOARD    Location    The circuit board is located inside the autofill box   mounted on the right side of the solenoid mounting  bracket under the switch panel     Test Procedure   1  Disconnect the dispenser from the power source   2  Disconnect the ten pin plug on the main wiring  harness from the connector on the circuit board   3  Connect the dispenser to the power source  With  a voltmeter  check the voltage across the black  wire  3  and the white wire   6   The indication  must be   a  120 volts ac for two wire 120 volt models   b  200 to 240 volts ac for two wire 200 or 240 volt  models        10        230 volts ac for two wire 230 volt models   4  Disconnect the dispenser from the power source     If voltage is present as described  replace the circuit  board    If 
29. to Main    Harness    83  2 AFPO 2     amp 3 43 AFPO 3  ONLY    FIG  17 SOLENOID TERMINALS       28791 040501    SERVICE  cont    SOLENOID  WATER  ON OFF SWITCHES    Removal and Replacement   1  Remove the wires from the switch terminals     2  Compress the clips inside the autofill box and  gently push the switch through the opening    3  Push the new switch into the opening and spread  the clips to hold switch in the autofill box    4  Refer to Fig  19 when reconnecting the wires         1 AFPO 2  amp 3    BLK from Pump Switch  2       P1521 BLK to Pump Switch  1  FIG 18 SOLENOID  WATER  ON OFF SWITCHES BLU to Test Operate Switch  Location  BLU to to Solenoid  1  The solenoid  water  ON OFF switches are located x   onthe switch mounting plate inside the autofill box on  2          2  amp  3    the right side     Test Procedure     1  Disconnect the dispenser from the power source  BLK from Main ON OFF Switch  2  Disconnectthe wires from the switch to be tested         to Pump Switch  2  3  Check for continuity across the terminals on the VIO to Test Operate Switch  switch when itis held in the on position  Continuity VIO to Solenoid  2  must not be present across these terminals in the          released position   3 AFPO 3 ONLY    If continuity is present as described  refer to Fig  19  and reconnect the wires to the switch   If continuity is not present as described  replace the BLK from Pump Switch 73    switch   WHI VIO to Test Operate Switch  WHI VIO to Solenoid  3     
30. voltage is not present as described  refer to the  Wiring Diagrams and check main wiring harness     Removal and Replacement   1  Remove the four 78 32 keps nuts securing the    switch mounting bracket  Set aside with the wires  attached    2  Remove the circuit board shield and set aside for  reassembly    3  Disconnect the ten pin plug from the main wiring  harness to the circuit board    4  Remove the six  4 40 screws and spacers secur   ing the circuit board to the solenoid mounting  bracket  Remove circuit board and discard    5  Install new circuit board using  4 40 screws and  spacers to secure the circuit board to the solenoid  mounting bracket  The spacers must be between  the solenoid mounting bracket and the circuit  board    6  Place circuit board shield over the circuit board    7  Install switch panel assembly and secure with four   8 32 keps nuts    8  Refer to Fig  3 for circuit board ten pin connector                 P1528    FIG  3 CIRCUIT BOARD CONNECTOR LOCATION    28791 040501    SERVICE  FUSE AND FUSE HOLDER       FIG  4 FUSE HOLDER  Location    The fuse holder is located on the lower right front  of the autofill box just to the left of the power cord     Test Procedure    1  Disconnect the dispenser from the power source   2  Remove cap and fuse from fuse holder    3  Remove fuse from the cap    4  Check for continuity through the fuse     If continuity is present  reinstall the fuse  the fuse is  operating properly   If continuity is not present  repla
    