Home

Bosch Appliances VIP XD Network Card User Manual

image

Contents

1. EN 8 Installation and User Guide VIP XD Installation and operation I The relevant electrical regulations and guidelines must be complied with at all times during installation Il Relevant knowledge of network technology is required to install the unit I Before installing or operating the unit make sure you have read and understood the documentation for the other equipment connected such as cameras This contains important safety instructions and information about permitted uses Il Perform only the installation and operating steps described in this manual Actions beyond these may lead to personal injury damage to property or damage to the equipment Maintenance and repair E Never open the casing of the VIP XD The unit does not contain any user serviceable parts Never open the housing of the power supply unit The power supply unit does not contain any user serviceable parts I Ensure that all maintenance or repair work is performed only by qualified personnel electrical engineering or network technology specialists Safety information Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 9 Product description Components supplied VIP XD network video server I Power supply unit with four primary adapters I Configuration cable I Quick start guide in English German Product CD with the following content Quick start guide in English German Us
2. Hardware version The hardware version number of the VIP XD is displayed Firmware version The firmware version number of the VIP XD is displayed Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 EN 37 Alarm settings Here you can make the settings for the alarm sources and alarm connections Alarm sources Alarm sources You can configure the alarm inputs on the VIP XD here Alarm input 1 Alarm input 4 Select the option On in order to activate the alarm via the corresponding external alarm sensor Otherwise select Off Select Active high if the alarm is to be triggered by closing the contact Select Active low if the alarm is to be triggered by opening the contact Name For easier identification you can enter a name for each alarm input Alarm connections Alarm connections You can select the response of the VIP XD in case of an alarm In case of an alarm the VIP XD can automatically establish a connection to a predefined IP address compatible MPEG 4 compatible video server You can enter up to ten Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 38 Installation and User Guide VIP XD IP addresses which will be selected in order by the unit in case of an alarm until a connection is established Connect on alarm Select On so that the VIP XD automatically establishes a connection to a pre defined IP addre
3. Check the IP address subnet mask and gateway address Device reset The Factory reset button can be used to reset all settings on the VIP XD to their original settings Any changes in the settings will be overwritten by the factory defaults This may be necessary for example if the unit has invalid settings that prevent it from functioning as desired A Warning All configured settings will be discarded during a reset If necessary back up the current configuration using the Download button on the Firmware and configuration upload configuration page see page 58 IS Note After a reset the unit can only be addressed via the factory default IP address The IP address can be changed as described in the chapter Installation see page 20 Bosch Security Systems 2005 05 V1 0 Maintenance and upgrades EN 72 Installation and User Guide VIP XD If necessary back up the current configuration using the Download button on the Firmware and configuration upload configuration page see page 58 Using a pointed object press the Factory reset button located below the USB interface until the operating status LED flashes red see page 13 All settings will revert to their defaults Change the IP address of the unit if necessary Configure the unit to meet your requirements Repairs A Warning Never open the casing of the VIP XD The unit does not contain any user serviceable parts E
4. Promi Profil Proni6 Profi Prom a m Screen resolution Resolution 800 x 500 Refresh rate 50 00 Hz Border top 0 Border right 1 Hor scan rate horiz spacing 4 vert spacing 4 32 250000 kHz _ Dot clock Border bottom Border left 31 089000 MHz Screen position Stepsize 1 v oma Pr os os E The pre configured settings are saved as Profile 1 to Profile 8 You can change the different parameter values within a profile You can switch between profiles by clicking the associated tabs The pre configured settings profiles cover all standard applications Only change the preset values if none of the profiles leads to satisfactory results A Warning Setting values that lie outside the technical specification of the monitor can result in severe damage to the monitor Refer to the technical documentation for the monitor you are using IS Note All parameters combine to make up a profile The parameters are partially independent of one another After each change click the Test button to see the effect of the change on the connected monitor Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 50 Installation and User Guide VIP XD Resolution You can enter the desired screen resolution in pixels here On digital flat screens LCD TFT and others the optimum resolution corresponds to the actual number of pixels lt gt Note By default
5. XD using a terminal program for example the HyperTerminal program that is part of Windows Connecting with a terminal program Various requirements must be met in order to operate using a terminal program see page 19 Start the terminal program and enter the command 1 in the main menu to switch to the IP menu Enter the command 4 in the IP menu to change the remote IP address then enter the IP address of the device to connect to Use the command 0 to return to the main menu Enter the command 4to switch to the Rep menu Enter the command 5 in the Rep menu to activate the automatic connection Closing the connection with a terminal program Start the terminal program see page 19 enter the command 4 in the main menu to switch to the Rep menu Enter the command 5 in the Rep menu to deactivate the automatic connection Additional parameters Using the terminal program you can check other basic parameters and modify them where necessary Use the on screen commands displayed in the various submenus to do this Bosch Security Systems 2005 05 V1 0 Operation with a terminal program EN 68 Operation with a terminal program Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 69 Operation with management software Managing and operating transmitters and receivers For operation of larger systems with multiple transmitters and rec
6. amended by 93 68 Low Voltage Directive Rating plate For exact identification the model name and serial number are inscribed on the rating plate on the bottom of the housing Please note this information if necessary before installation so it will be available in case of questions or for spare parts orders Preface Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 7 Safety information Electric shock hazard Never attempt to connect the unit to any power network other than the type for which it was intended Il Use only the power supply provided F Never open the housing I If a fault occurs disconnect the power supply unit from the mains supply and from all other devices Il Install the power supply and the unit only in dry weather protected areas I If safe operation of the unit cannot be ensured remove it from service and secure it to prevent unauthorized start up Safe operation is no longer possible in the following cases if there is visible damage to the unit or power cables if the unit no longer works properly if the unit has been exposed to rain or moisture if foreign matter has infiltrated the unit after long storage under adverse conditions or after exposure to extraordinary transport stress In such cases have the unit checked by Bosch Security Systems Bosch Security Systems 2005 05 V1 0 Safety information
7. and an appropriate mains socket is available Plug the power supply unit into a grounded mains socket The unit is ready for operation as soon as the operating status LED stops flashing red during start up and is lit green If the network connection is in order the green L LED is also lit The flashing orange T LED indicates data traffic on the network Installation Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 19 Setup using a terminal program Data terminal You can connect a data terminal to the VIP XD for setup and local control The data terminal consists of a computer with terminal software You can use the configuration cable supplied for the connection for assignment on the orange terminal block see page 76 HyperTerminal a communications accessory included with Microsoft Windows can be used as the terminal program I Note Information on installing and using HyperTerminal can be found in the user guides or online help for MS Windows Before using the terminal program disconnect the VIP XD from the data network and disconnect the power supply unit from the mains socket Connect the open lines of the configuration cable to the terminal block that is already connected to the power supply unit The assignment can be seen from the labels on the configuration cable and the markings on the terminal block Connect the terminal block to the orange socket on
8. are transferred to the unit by clicking Set However they only take effect after the unit is restarted Click Set after entering a new IP address To do this enter the old IP address followed by reset for instance 192 168 0 80 reset in the address bar of your web browser The VIP XD will be restarted after which it can only be accessed at the new IP address Unit IP address Enter the desired IP address for the VIP XD in this field The IP address must be valid for the network Subnet mask Enter the appropriate subnet mask for the set IP address here Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 40 Installation and User Guide VIP XD Gateway IP address If you want the unit to establish a connection to a remote location in a different subnet enter the IP address of the gateway here Otherwise this field can remain empty 0 0 0 0 Video audio transmission If the unit is used behind a firewall TCP Port 80 should be selected as the transmission protocol For use in a local network choose UDP A Warning Multicast operation is only possible with the UDP protocol The TCP protocol does not support multicast connections IS Note The MTU value in UDP mode is 1514 bytes Ethernet link type If the VIP XD is connected to the network via a switch both devices must have the same preset network connection type If necessary ask your network adminis
9. at the factory 192 168 0 1 Start the Web browser Enter the IP address of the VIP XD as the URL The connection will be established and after a short time you will see the SETTINGS page containing the unit overview and the configuration menu If the connection is not established the maximum number of possible connections may already have been reached The maximum number of connections depends on the device and network configuration Password protection in VIP XD If the VIP XD is password protected against unauthorized access a corresponding message and a prompt to enter the password will appear when you attempt to access protected areas Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 25 37 Note A VIP XD offers you the option of limiting access across various authorization levels see pages 35 and 44 Enter the user name and associated password in the corresponding text fields Click OK If the password is correct the desired page is displayed Choosing the configuration mode There are two options for configuring the VIP XD or checking the current setup I the unit overview or I the configuration menu All settings are stored in the VIP XD memory and they are preserved even if the power is interrupted Unit overview The unit overview shows the most important parameters summarized into six groups This all
10. received on the monitor connected to the VIP XD using a computer with Microsoft Internet Explorer version 6 0 or later installed Bosch Security Systems 2005 05 V1 0 Operation using a Web Browser EN 62 Installation and User Guide VIP XD Establishing the connection The VIP XD must be assigned a valid IP address to operate on your network The following default address has been pre set at the factory 192 168 0 1 Start the Web browser Enter the IP address of the VIP XD as the URL The connection will be established and after a short time you will see the SETTINGS page containing the unit overview and the configuration menu Password protection in VIP XD If the VIP XD is password protected against unauthorized access a corresponding message and a prompt to enter the password will appear when you attempt to access protected areas IS Note A VIP XD offers you the option of limiting access across various authorization levels see pages 35 and 44 Operation using a Web Browser Bosch Security Systems 2005 05 V1 0 EN 63 Enter the user name and the associated password in the appropriate fields Click OK If the password is correct the desired page is displayed Bosch Security Systems 2005 05 V1 0 Operation using a Web Browser EN 64 The CONNECTIONS page After the connection is established the SETTINGS page is displayed first Click on the CO
11. rule out typing mistakes 37 Note The new password is then saved by clicking the Set button You should therefore click the Set button immediately after entering and confirming the password even if you also want to assign a password to another user name Language Website language English x se Website language Select the language for the user interface here Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 36 Date and time Date and Time fruray afet oe fons Date format Choose the desired date format here Europe DD MM YYYY USA MM DD YYYY Japan YYYY MM DD Unit date and time If there are a number of devices operating in your system or network it is important to synchronize their internal clocks For example it is only possible to carry out correct identification and evaluation of recordings occurring at the same time if all devices are operating on the same time Enter the current date Since the unit time is controlled by the internal clock it is not necessary to enter the day of the week This is added automatically Enter the current time or click Synchr PC to apply the system time from your computer to the VIP XD Version information Version information F 1000340 15500100 The hardware and firmware version numbers are for information only and cannot be altered Keep a record of these numbers in case technical assistance is required
12. the unit Connect the VIP XD configuration cable to a free serial port on your computer Ensure that the correct primary adapter is fitted and connect the power supply unit to an appropriate mains socket Configuring the terminal To establish communication between the terminal program and the VIP XD the transmission parameters must be correctly defined The following values should be set in the terminal program E 19 200 Bit s I 8 data bits EI No parity check E 1 stop bit A No protocol Bosch Security Systems 2005 05 V1 0 Installation EN 20 Installation and User Guide VIP XD Command entry After the connection has been established you must log on to the VIP XD You can then access the main menu You can call up additional submenus and functions using the on screen commands If necessary turn off the local echo so that entered values are not repeated on the display Enter only one command at a time After entering a value such as an IP address re check the entry before pressing the ENTER key to transfer the values to the VIP XD Assigning an IP address To operate the VIP XD in your network a valid IP address for the network must be assigned The following default address has been pre set at the factory 192 168 0 1 Start up a terminal program such as HyperTerminal Enter the user name service The main menu will be displayed Enter the command 1 to o
13. 25 Connection on alarm 38 52 Connections 13 Conventions 5 D Danger 7 Data bits 41 55 Data interface 16 Data terminal 19 Date 46 Date format 36 46 Daylight saving time 47 Defaults 33 51 Device reset 71 Dome camera 16 E Echo 20 Electromagnetic compatibility 6 Encoder 27 EPROM 58 Establishing the connection 23 24 62 F Firewall 40 56 Firmware update 58 Firmware version 36 57 Function test 60 G Gateway 40 56 H Half duplex mode 42 55 Hardware version 36 57 l Identification 6 34 44 Image configuration 28 30 Bosch Security Systems 2005 05 V1 0 EN 82 Installation and User Guide VIP XD Installation 8 Installation conditions 15 Installation location 15 Interface mode 42 55 Internal clock 36 46 IP address 20 39 56 L Language 35 45 Language selection 35 45 Live video images 23 61 Low Voltage Directive 6 M Main functions 12 Maintenance 8 Make contact 17 Monitor 29 Monitor name 27 29 47 Monitor resolution 23 61 MPEG ActiveX 23 61 MPEG decoder 27 29 47 MTU value 40 57 Multicast connection 40 57 Multicast function 11 N Navigation 43 Network 16 39 56 Network check 71 Network connection 18 40 57 Number of connections 24 65 0 Operation 7 61 67 69 Output signal 27 29 47 Overview of functions 11 P Parameters 21 67 Parity check 41 55 Password 24 34 35 44 45 62 Pin assignment 76 Power supply
14. 7 Power switch 18 Profile settings 30 49 Protocol 42 55 Protocols 80 R Rear panel 13 Receiver password 38 53 Regulations 5 Relay 53 Relay output 17 53 Repair 8 72 Reset 71 Resetting the profile 33 51 Restart 21 RS232 76 RS422 RS485 76 S Safety 7 Screen size 28 30 48 Serial number 6 Serial port function 41 55 Setup 9 Signal source 17 Specifications 79 Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 83 Standard 76 Standards 80 Stop bits 41 55 Subnet mask 39 56 Switch 57 Symbols 5 Synchronous 36 46 System 34 System requirements 23 T TCP 40 56 Terminal 41 55 test 60 Time 36 46 Time server 46 Time server IP address 47 Time server protocol 46 Time signal 46 Time zone 46 Transmission parameters 19 Transmission protocol 40 56 Transmission rate 41 55 Transmission standards 16 Transmitter 11 Transparent 41 55 Trigger relay 54 Turn off 18 Turn on 18 U UDP 40 56 Unit date 36 46 Unit ID 34 44 Unit identification 34 44 Unit name 34 44 Unit overview 25 26 Unit time 36 46 Upload file 58 URL 24 62 User name 35 45 V Version 36 57 Video output signal 27 29 47 Bosch Security Systems 2005 05 V1 0 EN 84 Bosch Security Systems 2005 05 V1 0 Bosch Sicherheitssyteme GmbH Bosch Security Systems B V Robert Koch StraBe 100 P O Box 80002 85521 Ottobrunn 5600 JB E
15. D 15 pin VGA SVGA 0 7 Vg g 5 RGB analog 3 x LED operating voltage network connection data transmission on rear panel Temperature 0 50 C Relative humidity 20 80 non precipitating CE IEC 60950 UL 1950 AS NZS 3548 EN 55103 1 2 EN 55130 4 EN 55022 EN 55024 EN 61000 3 2 EN 61000 3 3 FCC 47 CFR Ch 1 Section 15 98 x 85 x 26 mm including feet and connections Approx 170 g Bosch Security Systems 2005 05 V1 0 Appendix EN 80 Installation and User Guide VIP XD Protocols standards Video standards PAL NTSC Video encoding protocols MPEG 4 with expansions Video data rate Max 20 MBit s 4 channels Image resolutions 720 x 576 480 pixels full D1 PAL NTSC 704 x 576 480 pixels 4CIF 352 x 576 480 pixels 1 2 D1 704 x 288 240 pixels 2CIF 352 x 288 240 pixels CIF 176 x 144 120 pixels QCIF Total delay IP 120 ms Network protocols RTP Telnet TCP UDP IP HTTP IGMP V2 ICMP ARP Appendix Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 81 Index A Actuator 17 Alarm 37 Alarm connections 37 Alarm input 17 37 76 Alarm input name 37 Alarm sources 37 52 Auto connect 38 53 B Basic data 34 Baud rate 41 55 Cc Cameras 16 Changes 26 43 Color depth 10 23 61 COM1 41 55 Components supplied 9 Configuration 23 59 Configuration download 59 Configuration menu 25 43 Configuration mode
16. Enter the desired IP address for the VIP XD in this field The IP address must be valid for the network Subnet mask Enter the appropriate subnet mask for the set IP address here Gateway IP address If you want the unit to establish a connection to a remote location in a different subnet enter the IP address of the gateway here Otherwise this field can remain empty 0 0 0 0 Video audio transmission If the unit is used behind a firewall TCP Port 80 should be selected as the transmission protocol For use in a local network choose UDP Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 57 A Warning Multicast operation is only possible with the UDP protocol The TCP protocol does not support multicast connections IS Note The MTU value in UDP mode is 1514 bytes Ethernet link type If the VIP XD is connected to the network via a switch both devices must have the same preset network connection type lf necessary ask your network administrator what value the associated switch is set to The Auto setting automatically detects the network connection If necessary you can specify the value 10 or 100 MBit s for full or half duplex mode FD or HD A Warning Malfunctions can occur for example image faults if the capacity of the network is not sufficient for transmission of the maximum data rate generated by the transmitter V
17. Installation and Operating Manual EN Network Video Server Installations und Bedienungshandbuch DE Netzwerk Video Server Installatie en bedieningshandleiding NL Netwerkvideoserver Manuel d installation et d utilisation FR Serveur vid o r seau Manuale di installazione e operativo IT Server video di rete Manual de instalacion y funcionamiento ES Servidor de canal de video Manual de Instalag o e Funcionamento PT Servidor de V deo de Rede Podrecznik inst pr Telepitesi s kezel si tmutat HU H l zati videoszerver PykoBoAcTBo No yCTaHOBKe n kcennyatTaynn RU Cetesoi BugeocepBep Kurulum ve Kullanma Kilavuzu TR Ag Video Sunucusu Eyxeipidio eykatdotaong Kal Agitoupyiacg EL Video Server diktUou Installations og betjeningsvejledning DA Netveerksvideoserver Installerings og brukerh ndbok NO Nettverksvideoserver Asennus ja k ytt opas FI Network Video Server BOSCH Copyright This user guide is the intellectual property of Bosch Security Systems and is protected by copyright All rights reserved No part of this document may be reproduced or transmitted for any purpose by whatever means electronic or mechanical without the express written permission of Bosch Security Systems Release May 2005 Software version 1 0 O Copyright 2005 Bosch Security Systems Note This user guide has been compiled with great care and the information it contains has bee
18. NNECTIONS link at the top of the window The page is opened and the VIP XD automatically browses the network for available transmitters Preview In this area you can select one of the video sources found in the network A snapshot of the video image from the selected video source is displayed In addition to the unit name the snapshot provides a further means of identifying the transmitter Monitor As soon as a connection is established to a transmitter you will see a snapshot from the video image from the connected transmitter here Operation using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 65 Connections between the transmitter and receiver When the CONNECTIONS page is called up the VIP XD automatically scans the network for available transmitters As soon as a transmitter is found in the network the VIP XD displays a JPEG snapshot from that transmitter All transmitters found are listed in the Video sources list field IS Note The transmitter and receiver must be located in the same subnet to establish a hardware connection see pages 39 and 56 Establishing the connection lt gt Note If the connection is not established the maximum number of possible connections may already have been reached The maximum number of connections depends on the device and network configuration Choose the desired transmitter from the Video sources list
19. XD RxD receive data RxD receive data plus TXD TxD transmit data TxD transmit data plus 12 V power supply 12 V power supply GND ground GND ground To operate the alarm inputs connect each alarm input to a ground contact GND via a trigger contact Appendix Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 77 Glossary Brief explanations of some of the terms and abbreviations found in this user guide are given below 10 100 Base T ARP Baud Bit s CIF DNS FTP Full duplex GOP HTTP ICMP ID IEEE IGMP Internet Protocol IP IP address ISDN JPEG kBit s LAN Local area network MAC IEEE 802 3 specification for 10 or 100 Mbit s Ethernet Address Resolution Protocol a protocol for mapping MAC and IP addresses Unit of measure for the speed of data transmission Bits per second the actual data rate Common Intermediate Format video format with 352 x 288 240 pixels Domain Name Service File Transfer Protocol Simultaneous data transmission in both directions sending and receiving Group of pictures Hypertext Transfer Protocol Internet Control Message Protocol Identification a machine readable character sequence Institute of Electrical and Electronics Engineers Internet Group Management Protocol The main protocol used on the Internet normally in conjunction with the Transfer Control Protoco
20. ace is made up of four terminals of the ST500 jack for pin assignment see page 76 The manufacturers of the relevant equipment can provide specific information on installation and operation A Warning Refer to the associated documentation when installing and operating the control unit This contains important safety instructions and information about permitted uses gt Note A video connection is necessary to transmit transparent data Network You can connect the VIP XD to a 10 100 Base T network Use a standard UTP Category 5 cable with RJ45 connectors for this Connect the unit to the network using the ETH jack Installation Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 17 Alarm inputs The VIP XD has four alarm inputs on the orange terminal block for pin assignment see page 76 The alarm inputs are used to connect to external alarm devices such as door contacts or sensors With the appropriate configuration an alarm sensor can for example trigger an automatic connection between the VIP XD and a particular transmitter A voltage free contact or switch can be used as an actuator lt gt Note If possible use a bounce free contact system as the actuator Connect the lines to the appropriate terminals on the orange terminal block IN1 to IN4 and check that the connection is secure Relay output The VIP XD has a relay output for switching externa
21. an configuration using a terminal program gt gt Note Make sure the graphics card is set to 16 or 32 bit colour depth and that Microsoft Virtual Machine is installed on your PC If necessary the required software and controls can be installed from the product CD provided see Components supplied page 9 Instructions for using the Web browser can be found in its online help System requirements I Microsoft Internet Explorer version 6 0 or higher I Monitor resolution 1024 x 768 pixels I Network access Intranet or Internet IS Note You should also take note of the information in the System requirements document on the product CD supplied Install MPEG ActiveX 3 Note In order to be able to play back live video images an appropriate MPEG ActiveX must be installed on the computer If necessary the required software and controls can be installed from the product CD provided see Components supplied page 9 Insert the CD into the CD ROM drive of the computer If the CD does not start automatically open the root directory of the CD in Windows Explorer and double click MPEGAx exe Follow the on screen instructions Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 24 Installation and User Guide VIP XD Establishing the connection The VIP XD must be assigned a valid IP address to operate on your network The following default address has been pre set
22. another After each change click the Test button to see the effect of the change on the connected monitor Resolution You can enter the desired screen resolution in pixels here On digital flat screens LCD TFT and others the optimum resolution corresponds to the actual number of pixels lt gt Note By default resolutions up to 800 x 600 pixels are supported Refresh rate Enter the desired refresh rate based on the technical specification of the monitor you are using For fluid video playback the setting 50Hz is used for PAL sources and the 60 Hz setting for NTSC sources lt gt Note For tube monitors higher refresh rates may be useful for ergonomic reasons However to prevent damage to monitors that do not support these refresh rates the exact monitor data must first be set using the terminal program see page 19 Border top bottom left right You can place a frame around the video image to make it easier to see You can set the width of all four borders individually The color of the frame gray tone can be specified in the Details window see page 32 Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 32 Installation and User Guide VIP XD horiz spacing vert spacing For four way division of the screen in addition to the outer frame you can also define separating lines between the different images You can set the width of the horizontal an
23. briefly Device is starting up Lit red continuously Defect on unit Upload failed LEDL Lit green Connected to the network LEDT Flashing orange Data transfer via the network Bosch Security Systems 2005 05 V1 0 Appendix EN 76 Installation and User Guide VIP XD Terminal block The terminal block is used to connect external signal sources or alarm switches as a relay output a serial interface or as a power supply Options for using the serial interface include transparent data transmission and operation of the unit with a terminal program Depending on the setting the serial interface uses the RS232 or RS244 285 standards The standard used depends on the current configuration see pages 41 and 55 Pin assignment NI IN3 GND R CTS RXD 7 7 7 7 7 7 WUUVDUUVU E MEE E R I IN2 IN4 GND RTS TXD The pin assignment for the serial interface depends on the standard used Pin RS232 standard RS422 485 standard IN1 Alarm input 1 Alarm input 1 IN2 Alarm input 2 Alarm input 2 IN3 Alarm input 3 Alarm input 3 IN4 Alarm input 4 Alarm input 4 GND GND ground GND ground GND GND ground GND ground R top Relay Relay R bottom Relay Relay CTS CTS clear to send RxD receive data minus RTS RTS ready to send TxD transmit data minus R
24. can result in severe damage to the monitor Refer to the technical documentation for the monitor you are using You can adapt the video output signal to the monitor you are using As well as the PAL and NTSC options for analog video monitors eight pre configured settings for VGA monitors are also available Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 48 Installation and User Guide VIP XD The pre configured settings each give priority to different factors resolution margin settings image refresh rate Details of the settings can be seen in the Video output standard field There you can also adapt the options to individual requirements if necessary Test different pre configured settings from the list to obtain an optimum monitor image After selecting a setting click on the Set button so that the setting takes effect at the video output Window layout You can specify the default image configuration for the monitor This can be also be selected at any time during operation on the CONNECTIONS page VGA monitor screen size Enter the aspect ratio of the screen here for example 4 x 3 or the physical size of the screen in millimeters This information allows the unit to accurately scale the video image for distortion free display Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 EN 49 VGA Settings Profil 4 Prom2 Pront3
25. ccccoco een Choosing the configuration mode Unit overview o oooooocccoco co Configuration menu 0 ee FUNCHON IES wie oe nak eee eee ann Chapter 6 Operation using a Web Browser Establishing the connection 22222220 The CONNECTIONS page 2 22 22 2er Connections between the transmitter and receiver Bosch Security Systems 2005 05 V1 0 EN 4 Installation and User Guide VIP XD Chapter 7 Operation with a terminal program Connecting with a terminal prograM oooccooo oo oo 67 Closing the connection with a terminal program 67 Additional parameters 0 00 eee eee ees 67 Chapter 8 Operation with management software Managing and operating transmitters and receivers 69 Chapter 9 Maintenance and upgrades Testing the network connection 00 2000 71 DEVICES distin A A rca 71 Repalrs spiras pea ei Re ner 72 Transfer and disposal 0 0 cee eee een nenn 72 Chapter10 Appendix Troubleshooting 22 222 2er ernennen nenn 73 LEDS CA San la fact ita 75 Terminal block ooooococcoooco en a 76 GIOSSAMY i za en en a 77 Specifications 0 eee 79 Chapter11 Index Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 5 Preface This user guide is intended for persons responsible for the installation and operation of the VIP XD Internat
26. click Browse to select the desired file Make certain that the file to be loaded comes from the same device type as the unit you want to reconfigure Click Upload to begin transmission to the unit The progress bar allows you to monitor the transfer Once the upload is complete the new configuration is activated The time remaining is shown by the message going to reset Reconnecting in seconds After the upload is completed successfully the unit will restart automatically Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 60 Installation and User Guide VIP XD Function test The VIP XD offers a variety of configuration options Therefore you should check that it works properly after installation and configuration This is the only way to ensure that the VIP XD will function as intended in the event of an alarm Your check should include the following functions Can the VIP XD be called remotely Il Does the VIP XD transmit all the data required Il Does the VIP XD respond to alarm events as required I Is it possible to control peripheral devices if necessary Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 61 Operation using a Web Browser Establishing the connection Itis possible to establish a connection to a compatible MPEG 4 video server and play back the live images
27. d vertical separating lines individually The color is identical to the frame color Screen position You can move the video image horizontally and vertically within the screen area In addition you can adjust the width and height of the video image Click on one of the four arrows in the large monitor graphic to move the video image in the corresponding direction Click on the plus or minus symbols next to the small monitor graphics to change the size of the video image Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 33 Resetting changes You can undo all changes to the profiles and reset each profile to its original settings Click on the Defaults button to reset the settings for the profile currently displayed to their default values Ifyou want to discard changes to a profile that have not yet been explicitly saved click on the Discard button You will see the last saved settings for that profile Saving changes When you have tested your settings on the connected monitor by clicking on the Test button you can save the new settings Saving only applies to the profile that is currently displayed Click on the Save button to save the current profile with the values displayed Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 34 Installation and User Guide VIP XD System
28. decoder VGA Presets El eV Qua Monitor name The monitor name is used for easy identification of the monitor location when using VIDOS the software for management of video surveillance systems Enter a unique unambiguous name here Video output standard A Warning Be sure to choose the correct video standard to avoid damaging the monitor Selecting a VGA setting with values outside the technical specification of the monitor can result in severe damage to the monitor Refer to the technical documentation for the monitor you are using You can adapt the video output signal to the monitor you are using As well as the PAL and NTSC options for analog video monitors eight pre configured settings for VGA monitors are also available The pre configured settings each give priority to different factors resolution border settings image refresh rate Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 30 Details of the settings can be seen in the VGA Settings field There you can also adapt the options to individual requirements if necessary Test different pre configured settings from the list to obtain an optimum monitor image After selecting a setting click on the Set button so that the setting takes effect at the video output Window layout You can specify the default image configuration for the monitor This can be also be selected at any time during operat
29. e is a free connection and call the transmitter again The unit does not report an alarm Alarm source is not selected Select possible alarm sources on the Alarm sources configuration page No alarm response specified Specify the desired alarm response on the Alarm connections configuration page if necessary change the IP address Control of cameras or other devices is not possible The cable connection between the serial interface and the connected device is incorrect Check all cable connections and ensure all plugs are properly plugged in The interface parameters conflict with those of the other device connected Make sure the settings of all devices involved are compatible The unit is not operational after firmware upload Power failure during programming by the update file Have the unit checked by Customer Service and replace if necessary Incorrect update file Enter the IP address followed by main htm in your web browser and repeat the upload Appendix Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 75 LEDs The VIP XD network video server has several LEDs on the rear panel that show the operating status and can give indications of possible malfunctions Operating status LED Not lit Unit is switched off Lit green Unit switched on Flashing green The unit is being accessed Lit red
30. een on the MPEG decoder configuration page in the VGA Settings field accessed using the Monitor icon in the unit overview Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 28 Installation and User Guide VIP XD Test different pre configured settings from the list to obtain an optimum monitor image After selecting a setting click on the Set button so that the setting takes effect at the video output I Note If necessary the presets for the VGA output signal can be viewed on the MPEG decoder page Monitor icon in the unit overview and adapted to individual requirements see page 29 Window layout You can specify the default image configuration for the monitor This can be also be selected at any time during operation on the CONNECTIONS page VGA monitor screen size Enter the aspect ratio of the screen here for example 4 x 3 or the physical size of the screen in millimeters This information allows the unit to accurately scale the video image for distortion free display Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 EN 29 Monitor settings On this page you can set the various options for the display of video images on an analog monitor or a VGA monitor Several presets are available for configuration of the VGA video output signal These presets can be adapted to individual requirements if necessary MPEG decoder MPEG
31. eivers the use of management software such as VIDOS is recommended VIDOS is a software package for operating controlling and administering CCTV installations Such as surveillance systems at remote locations It runs under Microsoft Windows operating systems Its main jobs are decoding video audio and control data received from a remote transmitter for convenient control of hardware connections There are many options available for operation and configuration when using a VIP XD with VIDOS Refer to the software documentation for more details Bosch Security Systems 2005 05 V1 0 Operation with management software EN 70 Operation with management software Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 71 Maintenance and upgrades Testing the network connection The ping command can be used to check the connection between two IP addresses This allows you to test whether a device is active in the network Open the DOS command prompt Type ping followed by the IP address of the device If the device is found the response appears as Reply from followed by the number of bytes sent and the transmission time in milliseconds Otherwise the device cannot be accessed via the network This might be because I The device is not properly connected to the network Check the cable connections in this case I The device is not correctly integrated into the network
32. er Guide EN 43 Configuration menu The configuration menu allows all parameters of the VIP XD to be configured You can view the current settings by opening one of the configuration pages The settings can be changed by entering new values or by selecting a predefined value in a list field Navigation You will see the configuration menu in addition to the unit overview after clicking on the SETTINGS link Click on one of the menu options on the left of the window The associated sub menu is opened Dow Click one of the links in the sub menu The corresponding page will be opened Making changes Each configuration page shows the current settings The settings can be changed by entering new values or by selecting a predefined value in a list field Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 44 After each change click Set to save the change A Warning Save each change with the associated Set button Clicking Set always saves only the settings in the particular field Changes in any other fields are ignored Unit identification Unit identification Unit name The unit can be assigned a name to assist in identifying it The name simplifies the management of multiple units in large video surveillance systems for example using the VIDOS software IS Note The unit name is used for remote identification of a unit in the event of an alarm f
33. er guide in English German System requirements data sheet MPEG ActiveX control MPEG viewer DirectX control Microsoft Internet Explorer Microsoft Virtual Machine Adobe Acrobat Reader 137 Note Check that the delivery is complete and in perfect condition Arrange for the unit to be checked by Bosch Security Systems if you find any damage System requirements for setup Computer with Windows 2000 XP operating system access to network and Microsoft Internet Explorer version 6 0 or later or Computer with Windows 2000 XP operating system an available serial port and terminal software Bosch Security Systems 2005 05 V1 0 Product description EN 10 Installation and User Guide VIP XD Configuration requirements Computer with Windows 2000 XP operating system network access and Microsoft Internet Explorer web browser version 6 0 or later or Computer with Windows 2000 XP operating system network access and management software for example VIDOS IS Note You should also take note of the information in the System requirements document on the product CD supplied Make sure the graphics card is set to 16 or 32 bit color depth and that Microsoft Virtual Machine is installed on your PC If necessary the required software and controls can be installed from the product CD provided see Components supplied page 9 Operational requirements Computer with Windows 2000 XP operat
34. ersion information Hardware version F1000340 Firmware version 15500100 The hardware and firmware version numbers are for information only and cannot be altered Keep a record of these numbers in case technical assistance is required Hardware version The hardware version number of the VIP XD is displayed Firmware version The firmware version number of the VIP XD is displayed Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 58 Installation and User Guide VIP XD Firmware and configuration upload Firmware and configuration upload Firmware update Durchsuchen Upload progress Configuration download Configuration upload ee Durchsuchen Firmware update The VIP XD is designed in such a way that its functions and parameters can be updated with firmware To accomplish this the current firmware package is transferred to the unit via the selected network It is automatically installed there Thus a VIP XD can be serviced and updated remotely without requiring a technician to make changes to the installation on site The current firmware can be obtained from your customer service center or from the Bosch Security Systems download area A Warning Before starting the firmware update make sure that you have selected the correct upload file Uploading the wrong files can result in the unit no longer being addressable requiring it to be replaced Do not i
35. field A JPEG snapshot from the selected video source will appear in the Preview area Enable the Include data checkbox if you also want to transmit transparent data Ensure that the transmitter and receiver are correctly configured for data transmission gt Note The checkbox must be enabled before establishing the connection for data transmission to be activated Click in the checkbox again to deactivate the data connection Click Connect MPEG 4 to begin displaying the video images on the connected monitor In the Monitor area you will see a snapshot of the connected video source Ifthe transmitter is a multi channel unit for example a VideoJet 8008 you can set the Video input for playback Change from Single view to Quad view by activating the respective radio button If you want to set up more than one connection simultaneously choose a different decoder stream for each connection in Decoder Bosch Security Systems 2005 05 V1 0 Operation using a Web Browser EN 66 Terminating the connection Click on the X icon above the Monitor window to end the display of the video images on the connected monitor Operation using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 67 Operation with a terminal program As well as using Microsoft Internet Explorer you can also control the establishment of a connection from the VIP
36. indhoven Germany The Netherlands www bosch sicherheitssysteme de www boschsecuritysystems com 2005 Bosch Sicherheitssysteme GmbH Subject to change Printed in Germany 2503B 0505 en 1 BOSCH
37. ing system network access and Microsoft Internet Explorer web browser version 6 0 or later or Computer with Windows 2000 XP operating system network access and management software for example VIDOS 3 Note You should also take note of the information in the System requirements document on the product CD supplied Make sure the graphics card for reception on the computer monitor is set to 16 or 32 bit color depth and that Microsoft Virtual Machine is installed and activated on the PC If necessary the required software and controls can be installed from the product CD provided see Components supplied page 9 Product description Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 11 Overview of functions Network video receiver with Quad View The VIP XD is an ultra compact network video receiver for simultaneous reception of up to four video streams It is primarily designed for decoding video data after transfer over an IP network and for transmission of control data When connected to a monitor and used in conjunction with compatible MPEG 4 video servers the VIP XD is ideally suited for making previously analog CCTV systems IP compatible About the size and shape of a cigarette packet it can be integrated into small housings without difficulty if necessary The use of existing networks means that integration with CCTV systems or local networks can be achieved quickly and easi
38. ion on the CONNECTIONS page VGA monitor screen size Enter the aspect ratio of the screen here for example 4 x 3 or the physical size of the screen in millimeters This information allows the unit to accurately scale the video image for distortion free display VGA Settings VGA Settings Profil 4 Profl2 Pront3 Promi Profil proie Profl7 Profile m Screen resolution Resolution 800 x 500 Refresh rate 50 00 Hz Border top 0 Border right 1 Hor scan rate horiz spacing 4 vert spacing 4 32 250000 kHz r o Dot clock Border bottom Border left 31 089000 MHz Screen position Stepsize 1 v oa Pre E Pose E The pre configured settings are saved as Profile 1 to Profile 8 You can change the different parameter values within a profile You can switch between profiles by clicking the associated tabs Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 31 The pre configured settings profiles cover all standard applications Only change the preset values if none of the profiles leads to satisfactory results A Warning Setting values that lie outside the technical specification of the monitor can result in severe damage to the monitor Refer to the technical documentation for the monitor you are using IS Note All parameters combine to make up a profile The parameters are partially independent of one
39. ional national and any regional regulations regarding electronics must be followed at all times Relevant knowledge of network technology is required The user guide describes the installation and operation of the unit Conventions In this user guide the following symbols and notation are used to draw attention to special situations A Warning This symbol indicates that failure to follow the safety instructions described may endanger persons and cause damage to the unit or other equipment It is associated with immediate direct hazards IS Note This symbol indicates tips and information for easier more convenient use of the unit Bosch Security Systems 2005 05 V1 0 Preface EN 6 Installation and User Guide VIP XD Intended use The VIP XD network video server receives video and control signals over data networks Ethernet LAN Internet It is designed for use in CCTV systems By incorporating external alarm sensors various functions can be triggered automatically Other applications are not permitted In the event of questions concerning the use of the unit which are not answered in this user guide please contact your sales partner or Bosch Sicherheitssyteme GmbH Robert Koch Stra e 100 85521 Ottobrunn Germany www bosch sicherheitssysteme de EU Directives The VIP XD network video server complies with the requirements of EU Directives 89 336 Electromagnetic Compatibility and 73 23
40. l RFC 868 and then use it to set the internal clock The unit calls up the time signal automatically every ten minutes Time zone Select the time zone in which the system is located Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 47 Time settings Select this during daylight savings time if the time change is to be taken into account Deactivate the check box to switch to winter time Time server IP address Enter the IP address of a time server that uses the RFC 868 protocol MPEG decoder On this page you can set the various options for the display of video images on an analog monitor or a VGA monitor Several presets are available for configuration of the VGA video output signal These presets can be adapted to individual requirements if necessary MPEG decoder Monitor name Monitor 1 Video output standard VGA Preset 5 Window layout C Singleview Quad view VGA monitor screen size undefined x undefined Width x Height mm se Monitor name The monitor name is used for easy identification of the monitor location when using VIDOS the software for management of video surveillance systems Enter a unique unambiguous name here Video output standard A Warning Be sure to choose the correct video standard to avoid damaging the monitor Selecting a VGA setting with values outside the technical specification of the monitor
41. l TCP TCP IP See Internet Protocol A 4 byte number uniquely defining each device on the Internet It is usually written in dotted decimal notation with full stops separating the bytes for example 209 130 2 193 Integrated Services Digital Network An encoding process for still images Joint Photographic Experts Group Kilobits per second the actual data rate See Local area network A communications network serving users within a limited geographical area such as a building or a university campus It is controlled by a network operating system and uses a transfer protocol Media Access Control Bosch Security Systems 2005 05 V1 0 Appendix EN 78 Installation and User Guide VIP XD MPEG 4 Multicasting Net mask Parameters QCIF RFC 868 RS232 RS422 RS485 RTP Subnet mask TCP Telnet TTL UDP URL UTP WAN Wide area network Further development of MPEG 2 designed for transmission of audiovisual data at very low transfer rates for example via the Internet Multiple use of a transmitter data stream by multiplication of the data stream in the network nodes switches and only where the data is required to save bandwidth in the network These connections are managed using IGMP A mask that explains which part of an IP address is the network address and which part comprises the host address It is usually written in dotted decimal notation with full stops separating the b
42. l devices such as lights or audible alarms This relay output can be activated manually during a connection session with the VIP XD Moreover the output can be configured to activate audible alarms or other devices as a response to an alarm signal The relay output is also located on the orange terminal block for pin assignment see page 76 A Warning The maximum rating of the relay contact is 30 V and 2 A Connect the lines to the appropriate terminals R on the orange terminal block and check that the connection is secure Bosch Security Systems 2005 05 V1 0 Installation EN 18 Installation and User Guide VIP XD Turning on off Mains connection The VIP XD includes a mains power supply with four primary adapters and terminal block The VIP XD does not have a power switch The unit is ready for operation as soon as it is connected to the power supply A Warning To operate the VIP XD use exclusively the power supply unit supplied with the correct primary adapter for your mains socket Use suitable equipment where necessary to ensure that the mains supply is free of interference such as voltage surges spikes or voltage drops A Warning Only connect the VIP XD to the mains supply once everything else has been connected Connect the cable to the power supply unit and the orange terminal block of the VIP XD Ensure that the correct primary adapter is attached to the power supply unit
43. ly Two units for example a VIP X1 VIP X2 as the transmitter and another VIP XD as the receiver can form a stand alone system for data transfer without a PC Video images from a single transmitter can be simultaneously received on several receivers A VIP XD receiver can simultaneously receive up to four video streams from one or more compatible transmitters Transmitter MPEG 4 compatible hardware decoders for example VIP X 1 VIP X 2 or VideoJet 8008 can be used as transmitters Computers with the VIDOS software installed are suitable for connecting the desired transmitters to the relevant receiver Multicast In suitably configured networks the multicast function enables simultaneous real time transmission to multiple receivers The prerequisite for this is that the UDP and IGMP V2 protocols are implemented on the network Configuration The VIP XD can be configured using a browser on the local network Intranet or from the Internet Similarly firmware updates and rapid loading of device configurations are also possible Bosch Security Systems 2005 05 V1 0 Product description EN 12 Product description Bosch Security T Ofsi P23 Se rS VIP XD Installation and User Guide EN 13 Connections on front and rear panel IN IN3 GND R as RXD N DPUUUUUU uss lee EH OJO NON NO NONO Li L p o IN2 IN4 GND R RTS TXD O O 3 4 5 6 fe 8 9 1 Video ou
44. n thoroughly verified The text was complete and correct at the time of printing The ongoing development of the products may mean that the content of the user guide can change without notice Bosch Security Systems accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between the user guide and the product described Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly VIP XD Installation and User Guide EN 3 Contents Chapter 1 Preface CONVENTIONS vecinas oa ad ia Intended USe 422 2 2u bee aan en EU Directives cian kobe aod ek en Rating plate ueniren i re Chapter 2 Safety information Electric shock hazard oooooooocooommmoo Installation and operati0N oo ooo oooooo Maintenance and repair ooocooccooccoooo o Chapter 3 Product description Components supplied 2 222222202 e ee eee eee System requirements for setup o o Configuration requirements 2 222 222 Operational requirements 2222er Overview of functions 2 222222 seen eee Connections on front and rear panel Chapter 4 Installation Connections 0 0 cc eee n nn Turning ONO ooo occ Setup using a terminal program 2 22 22 20 Chapter 5 Configuration using a Web Browser COMMECtINQ oooco
45. nsure that all maintenance or repair work is performed only by qualified personnel electrical engineering or network technology specialists In case of doubt contact your dealer s technical service center Transfer and disposal The VIP XD should only be passed on together with this installation and user guide The unit and its power supply contain environmentally hazardous materials that must be disposed of properly and in line with the legal requirements Defective or superfluous devices and parts should be disposed of professionally or taken to your local collection point for hazardous materials Maintenance and upgrades Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 73 Appendix Troubleshooting If you cannot resolve a fault please contactyour supplier or system integrator or go direct to Bosch Security Systems Customer Service The version numbers of the internal processors can be viewed on a special page Please note this information before contacting Customer Service Inthe address bar of your browser after the unit IP address enter version htm for example 192 168 0 3 version htm Write down the information or print out the page The following table is intended to help you identify the causes of malfunctions and correct them where possible Malfunction Possible causes Solution No connection Incorrect cable connections Check all cables plugs c
46. nterrupt the firmware installation for any reason Interruption will result in incorrect programming of the Flash EPROM This can result in the unit no longer being addressable requiring it to be replaced First save the update file to the hard disk Enter the full path for the update file in the field or click Browse to locate and select the file Click Upload to begin transmission to the unit The progress bar allows you to monitor the transfer The new firmware is unpacked and the flash EPROM is reprogrammed The time remaining is shown by the message going to reset Reconnecting in seconds After the upload is completed successfully the unit will restart automatically If the operating status LED lights up red the upload has failed and must be repeated To perform the upload you must switch to a special page Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 59 Inthe address bar of your browser after the unit IP address enter main htm for example 192 168 0 80 main htm Repeat the upload Configuration download You can save configuration data for the VIP XD to a computer and load saved configuration data from a computer to the unit Click Download A dialog will appear Follow the instructions to save the current settings Configuration upload Enter the full path of the file to upload or
47. of the video image Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 51 lt gt Note If the horizontal and vertical scaling of the monitor image is changed the new values for Hor scan rate and Dot clock are immediately displayed in the fields above the monitor graphics for information You cannot enter or change these values directly in the fields Details The Details window allows you to adapt the video output signal to specific requirements in more detail In addition you can set the frame color for the image border Horizontal sync Vertical synch Here you can select the way in which the relevant synchronization pulse is to be output Bordercolor Here you can set the desired gray tone for the outer frame and any separating lines between the video images for four way division of the screen Click on the arrows or move the slider with the mouse button held down Sync length Retrace length Sync position Here you can adjust the settings for the synchronization signals to specific requirements if necessary Reset changes You can undo all changes and reset each profile to its original settings Click on the Defaults button to reset the settings for the profile currently visible to their default values If you want to discard changes to a profile that have not yet been explicitly saved click on the Discard button Y
48. ontacts between the unit and terminals and connections terminal program The computer s serial Check the other serial interfaces interface is not connected Interface parameters do not Select a different interface if match necessary and make sure that the computer s interface parameters match those of the unit If necessary try the following standard parameters 19 200 baud 8 data bits no parity 1 stop bit Then disconnect the unit from the mains and reconnect it again after a few seconds No image on the Monitor error Connect local camera or other monitor video source to the monitor and check the monitor function No Defective camera Connect a local monitor to the image transmission camera and check the camera function Faulty cable connections Check all cables plugs contacts and connections Bosch Security Systems 2005 05 V1 0 Appendix EN 74 Installation and User Guide VIP XD Malfunction Possible causes Solution No connection established no The unit s configuration Check all configuration parameters image transmission Faulty installation Check all cables plugs contacts and connections Wrong IP address Check the IP addresses terminal program Faulty data transmission within the LAN Check the data transmission with ping The maximum number of connections has been reached Wait until ther
49. or example Enter a name that makes it as easy as possible to identify the location unambiguously Unit ID Each VIP XD should be assigned a unique identifier that can be entered here as an additional means of identification Password Password A EEE N A VIP XD is generally protected by a password to prevent unauthorized access to the unit You can use various authorization levels User name to limit access Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 45 lt gt Note Proper password protection with a user password is only guaranteed if the higher authorization level service is also protected by a password The passwords for the service authorization level should therefore always be assigned first User name The VIP XD operates with two user names service and user which correspond to different authorization levels The user name service represents the highest authorization level After entering the corresponding password you can use it to access all the functions of the VIP XD and change all configuration settings The user name user represents the middle authorization level You can use it to connect the unit to a transmitter in the network and to disconnect but not to change the configuration Password You can define and change a separate password for each user name if you are logged on as service or if the unit is not
50. ou will see the last saved settings for that profile Saving changes When you have tested your settings on the connected monitor by clicking on the Test button you can save the new settings Saving only applies to the profile that is currently displayed Click on the Save button to save the current profile with the values displayed Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 52 Alarm sources Alarm sources You can configure the alarm inputs on the VIP XD here Alarm input 1 Alarm input 4 Select the option On in order to activate the alarm via the corresponding external alarm sensor Otherwise select Off Select Active high if the alarm is to be triggered by closing the contact Select Active low if the alarm is to be triggered by opening the contact Name For easier identification you can enter a name for each alarm input Alarm connections Alarm connections You can select the response of the VIP XD in case of an alarm In case of an alarm the VIP XD can automatically establish a connection to a predefined IP address compatible MPEG 4 compatible video server You can enter up to ten IP addresses which will be selected in order by the unit in case of an alarm until a connection is established Connect on alarm Select On so that the VIP XD automatically establishes a connection to a pre defined IP address in the event of an alarm Configuration
51. ows you to change the default settings with just a few clicks and entries see Unit overview page 26 Configuration menu The configuration menu is recommended for expert users or system administrators All unit parameters can be accessed in this mode Changes that influence the fundamental functioning of the unit for example firmware updates can only be made using the configuration menu see Configuration menu page 43 Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 26 Unit overview The unit overview gives you a graphical overview of the individual areas of the configuration The individual configuration parameters are grouped and displayed in separate windows You can access the individual areas directly ad E Decoder Monitor Click one of the group graphics A new page is opened Click in the text fields to enter values or use the other controls available such as buttons check boxes or list fields Click on the SETTINGS link at the top of the window to close the window without saving the changes made Making changes After making changes in a window click the Set button to send the new settings to the unit and save them there A Warning Save the changes made in each window by clicking Set Clicking the Set button always saves only the settings in the current window A description is given below of the individual windows that can be accessed using the gra
52. pen the IP menu VIP X HyperTerminal Datei Bearbeiten Ansicht Anrufen Ubertragung 0653 08 E VIP_X 0 Exit menu IP reset after change necessary 1 local IP 192 168 0 1 DM Lanal cubrot fe 9ER OREA A Enter 1 again The current IP address will be displayed and you will be requested to enter a new IP address Installation Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 21 Enter the desired IP address and press Enter The new IP address will be shown Use the commands displayed for any additional settings required lt gt Note The new IP address and a new subnet mask or gateway address will only be valid after restarting Restart Briefly disconnect the power supply to the VIP XD disconnect power supply unit and re connect after a few seconds Additional parameters Using the terminal program you can check other basic parameters and modify them where necessary Use the on screen commands displayed in the various submenus to do this Bosch Security Systems 2005 05 V1 0 Installation EN 22 Installation Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 23 Configuration using a Web Browser Connecting The integrated HTTP server allows the unit to be configured over the network with a Web browser This option is significantly more comprehensive and convenient th
53. phical symbols in the overview Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 27 Decoder settings On this page you can set the various options for the display of video images on an analog monitor or a VGA monitor Several presets are available for configuration of the VGA video output signal MPEG decoder MPEG decoder Monitor name Monitor 1 Video output standard VGA Preset 5 y Window layout C Single view Quad view VGA monitor screen size undefined x undefined Width x Height mm se Monitor name The monitor name is used for easy identification of the monitor location when using VIDOS the software for management of video surveillance systems Enter a unique unambiguous name here Video output standard A Warning Be sure to choose the correct video standard to avoid damaging the monitor Selecting a VGA setting with values outside the technical specification of the monitor can result in severe damage to the monitor Refer to the technical documentation for the monitor you are using You can adapt the video output signal to the monitor you are using As well as the PAL and NTSC options for analog video monitors 8 pre configured settings for VGA monitors are also available The pre configured settings each give priority to different factors resolution margin settings refresh rate Details of the settings can be s
54. protected by a password Enter the password for the selected user name here Confirm password Re enter the new password to rule out typing mistakes 37 Note The new password is then saved by clicking the Set button You should therefore click the Set button immediately after entering and confirming the password even if you also want to assign a password to another user name Language Website language English sa Website language Select the language for the user interface here Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser Date and time Date and Time Fmursday Pr fos 005 Date format Choose the desired date format here Europe DD MM YYYY USA MM DD YYYY Japan YYYY MM DD Unit date and time If there are a number of devices operating in your system or network it is important to synchronize their internal clocks For example itis only possible to carry out correct identification and evaluation of recordings occurring at the same time if all devices are operating on the same time Enter the current date Since the unit time is controlled by the internal clock itis not necessary to enter the day of the week This is added automatically Enter the current time or click Synchr PC to apply the system time from your computer to the VIP XD Time server Time server The VIP XD can receive the time signal from a time server using the time server protoco
55. resolutions up to 800 x 600 pixels are supported Refresh rate Enter the desired refresh rate based on the technical specification of the monitor you are using For fluid video playback the setting 50Hz is used for PAL sources and the 60 Hz setting for NTSC sources lt gt Note For tube monitors higher refresh rates may be useful for ergonomic reasons However to prevent damage to monitors that do not support these refresh rates the exact monitor data must first be set using the terminal program see page 19 Border top bottom left right You can place a frame around the video image to make it easier to see You can set the width of all four borders individually The color of the frame gray tone can be specified in the Details window see page 51 horiz spacing vert spacing For four way division of the screen in addition to the outer frame you can also define separating lines between the different images You can set the width of the horizontal and vertical separating lines individually The color is identical to the frame color Screen position You can move the video image horizontally and vertically within the screen area In addition you can adjust the width and height of the video image Click on one of the four arrows in the large monitor graphic to move the video image in the corresponding direction Click on the plus or minus symbols next to the small monitor graphics to change the size
56. settings Various basic data for the VIP XD can be set or selected here Unit identification Unit name The unit can be assigned a name to assist in identifying it The name simplifies the management of multiple units in large video surveillance systems for example using the VIDOS software Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 35 lt gt Note Proper password protection with a user password is only guaranteed if the higher authorization level service is also protected by a password The passwords for the service authorization level should therefore always be assigned first User name The VIP XD operates with two user names service and user which correspond to different authorization levels The user name service represents the highest authorization level After entering the corresponding password you can use it to access all the functions of the VIP XD and change all configuration settings The user name user represents the middle authorization level You can use it to connect the unit to a transmitter in the network and to disconnect but not to change the configuration Password You can define and change a separate password for each user name if you are logged on as service or if the unit is not protected by a password Enter the password for the selected user name here Confirm password Re enter the new password to
57. ss in the event of an alarm With the setting Follows alarm 1 the VIP XD automatically establishes a connection to a remote station and maintains it for as long as an alarm signal is present at alarm input 1 This option can also be used to connect two units transmitter and receiver via a switch connected to the VIP XD In this case no computer is needed to establish the connection Number of destination IP address Here you assign the numbering for the IP addresses to be contacted in the event of an alarm The unit contacts the remote locations one after the other in the numbered sequence until a connection has been established Destination IP address For each number enter the corresponding IP address for the desired remote location Destination password If the remote location is password protected enter the password here Auto connect Select the option On if an active connection should be re established automatically to one of the previously specified IP addresses after each restart after a connection breakdown or network failure Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 EN 39 Network settings Here you can specify network addresses and configure multiple connections Network Network 10 0 32 29 0 0 0 0 The settings on this page are used to integrate the unit into an existing network A Warning Changes to the IP address subnet mask or gateway address
58. tems 2005 05 V1 0 EN 55 COM1 You can configure the parameters of the serial interface to meet your requirements Serial port function Select the desired serial port function from the list If you want to use the serial port to transmit transparent data for example when using a control panel select Transparent To operate the unit with a terminal choose Terminal Baud rate Select the value for the transmission rate in Bit s Data bits The number of data bits per character cannot be changed Stop bits Select the number of stop bits per character Parity check Select the type of parity check Interface mode Select the desired protocol for the serial interface Half duplex mode Choose the setting appropriate for your application Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 56 Network Network The settings on this page are used to integrate the unit into an existing network A Warning Changes to the IP address subnet mask or gateway address are transferred to the unit by clicking Set However they only take effect after the unit is restarted Click Set after entering a new IP address To do this enter the old IP address followed by reset for instance 192 168 0 80 reset in the address bar of your web browser The VIP XD will be restarted after which it can only be accessed at the new IP address Unit IP address
59. tput Video Out BNC jack for connection of video monitor 2 Video output VGA Sub D jack for connection of computer monitor 3 USB interface for future expansion of recording function 4 Factory reset button to restore factory default settings 5 Terminal block for alarm inputs relay output serial interface and power supply 6 Operating status LED lights up green when ready for operation 7 LEDL lit green when the unit is connected to the network 8 LEDT flashes orange when data is being transmitted over the network 9 RJ45 jack ETH for connecting to an Ethernet LAN local network 10 100 MBit s Base T Further information on the LEDs can be found on page 75 Information about the pin assignment can be found on page 76 Bosch Security Systems 2005 05 V1 0 Product description EN 14 Product description Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 15 Installation Thanks to its ultra compact dimensions the VIP XD is particularly well suited for installation in housings or consoles where space is at a premium A Warning The unit is intended for use indoors or in protected spaces Select a suitable location for installation where the unit will not be subjected to conditions of extreme temperature or humidity The ambient temperature must be between 0 and 50 C and the relative humidity may not exceed 80 The unit generates heat during operation Ens
60. trator what value the associated switch is set to The Auto setting automatically detects the network connection If necessary you can specify the value 10 or 100 MBit s for full or half duplex mode FD or HD A Warning Malfunctions can occur for example image faults if the capacity of the network is not sufficient for transmission of the maximum data rate generated by the transmitter Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 EN 41 COM1 settings You can configure the parameters of the serial interface to meet your requirements Serial port function Select the desired serial port function from the list If you want to use the serial port to transmit transparent data for example when using a control panel select Transparent To operate the unit with a terminal choose Terminal Baud rate Select the value for the transmission rate in Bit s Data bits The number of data bits per character cannot be changed Stop bits Select the number of stop bits per character Parity check Select the type of parity check Bosch Security Systems 2005 05 V1 0 Configuration using a Web Browser EN 42 Interface mode Select the desired protocol for the serial interface Half duplex mode Choose the setting appropriate for your application Configuration using a Web Browser Bosch Security Systems 2005 05 V1 0 VIP XD Installation and Us
61. ty Systems 2005 05 V1 0 Configuration using a Web Browser EN 54 Installation and User Guide VIP XD maintained In monostable operation the time can be selected after which the relay reverts to its idle state You can choose various events that activate the output automatically Thus for example it is possible to switch on a spotlight in response to a motion alarm and switch it off again when the alarm is over Idle state Select Open if the relay is to operate as a normally open contact or Closed if it is to operate as a normally closed contact Operating mode Select an operating mode for the relay If for example a lamp switched on by an alarm is to remain lit when the alarm has ended select Bistable If an acoustic signal activated by an alarm is to sound for a period of ten seconds for example select 10 sec Relay follows For each number enter the corresponding IP address for the desired remote location I Off No relay triggering by events Connection Triggering if any connection is established Remote input 1 Triggering by a relay contact at a remote location only when a connection is established Relay name The relay can be assigned a name here The name will be shown on the button next to Trigger relay Trigger relay Click the button to switch the relay manually for example for testing purposes or to operate a door opener Configuration using a Web Browser Bosch Security Sys
62. ure that there is adequate ventilation and also that there is enough clearance between the unit and heat sensitive objects or equipment Please ensure the following conditions for installation I Do not install the unit close to heaters or other heat sources Avoid locations subject to direct sunlight Il Allow sufficient space for running cables Ensure that the unit has adequate ventilation I Use only the cables supplied for connections or appropriate cables resistant to electromagnetic interference Position and run all cables so that they are protected from damage and provide strain relief where needed Avoid impacts blows and severe vibrations as these can lead to irreparable damage to the unit Bosch Security Systems 2005 05 V1 0 Installation EN 16 Installation and User Guide VIP XD Connections Monitors If required you can connect an analog video monitor PAL NTSC or a VGA compatible computer monitor Connect an analog video monitor to the BNC jack Video Out with a video cable 75 Ohm BNC connector or Connect a VGA compatible computer monitor to the Sub D jack VGA with a video cable VGA 15 pin Sub D connector Data interface The bi directional data interface is used to transmit control data for a unit connected to the VIP XD such as a control panel for dome cameras The interface supports the RS232 RS422 and RS485 transmission standards The serial interf
63. using a Web Browser Bosch Security Systems 2005 05 V1 0 EN 53 With the setting Follows alarm 1 the VIP XD automatically establishes a connection to a remote station and maintains it for as long as an alarm signal is present at alarm input 1 This option can also be used to connect two units transmitter and receiver via a switch connected to the VIP XD In this case no computer is needed to establish the connection Number of destination IP address Here you assign the numbering for the IP addresses to be contacted in the event of an alarm The unit contacts the remote locations one after the other in the numbered sequence until a connection has been established Destination IP address For each number enter the corresponding IP address for the desired remote location Destination password If the remote location is password protected enter the password here Auto connect Select the option On if an active connection should be re established automatically to one of the previously specified IP addresses after each restart after a connection breakdown or network failure Relay You can configure the switching behavior of the relay output Open switch relay normally closed contact or a closed switch relay normally open contact can be specified It is also possible to specify whether the output should in a bistable or monostable manner In bistable operation the activated state of the relay is Bosch Securi
64. ytes for example 255 255 255 192 Values used for configuration Quarter CIF a video format with 176 x 144 120 pixels A protocol for synchronizing computer clocks over the Internet Standards for serial data transmission Realtime Transport Protocol A transmission protocol for real time video and audio See Net mask Transfer Control Protocol Login protocol with which users can log on to a remote computer host on the Internet Time To Live life cycle of a data packet in station transfers User Datagram Protocol Uniform Resource Locator Unshielded Twisted Pair See wide area network A long distance link used to extend or connect remotely located local area networks Appendix Bosch Security Systems 2005 05 V1 0 VIP XD Installation and User Guide EN 79 Specifications Unit Operating voltage Power consumption LAN interface Data interfaces Alarm inputs Relay output Video outputs Displays Operating conditions Regulatory approvals Dimensions w x h x Weight 12 24 V DC power supply unit with various primary adapters included approx 7 VA 1 x Ethernet 10 100 Base T automatic adaptation half full duplex RJ45 1 x RS232 RS422 RS485 bi directional ST500 1 x USB 2 0 for future expansions 4 x push in terminals non isolated closing contact max trip resistance 10 Ohm 1 x push in terminal 30 Vg s 2A 1 x BNC 1 0 Vg s 5 75 Ohm PAL NTSC 1 x Sub

Download Pdf Manuals

image

Related Search

Related Contents

Approx 15.6" Carry case + USB Mouse  EXPERT SERIES 2 BASIC  Omnitron iConverter 10/100M2  Chapter 7  User Manual Login & Password  Manuel d`utilisation Modèle SDL500  mode d emploi kit piscine couloir de nage  Topcon A3280 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file