Home
Bolens 544 Lawn Mower User Manual
Contents
1. 7 on the C900V2 with the plastic standoffs 4 and the enclosure mounting brackets 5 4 Insert two screws 8 into the holes and slowly tighten until the C900V2 is secured firmly to the enclosure Figure4 C900V2 in AE2 Enclosure Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide Contents 2 2 Wiring Figure 5 Wiring to a DS7400Xi in the Same Enclosure 3 leere KG ne elo Le i O OO l LL o M l WOVE sh KISS IN 1 C900V2 5 Battery 2 ToLAN or WAN port 6 EOL resistor for the control panel attached to 3 DS7400Xi Control Panel terminals 4 Non power limited area 7 DS7481 Single Phone Line Monitor optional NOTE All power limited wiring must be atleast 8 Telco jack 6 4 mm 0 25 in from the battery wiring 9 RJ31X 10 House telephone You can use the C900V2 with a variety of control The DS7400Xi is the only control panel panels The next sections provide information for approved by UL to be wired in the same wiring the C900V2 to a generic control panel Refer enclosure as the C9
2. ENTER Refer to Table 9 Contact your network administrator if you need more information about the netmask This prompt appears Change telnet config password lt N _ o Press ENTER to accept the password setting at none PN In most cases do not assign a password If a password is necessary store it in a safe place If you lose or forget the password you cannot connect to C900V2 using telnet until you send the unit to the factory for password removal and the unit is returned to you The Setup Mode information appears Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide 4 0 erial Number 5221484 WAC address BRI28 46 52 53 FC oftware version Ufid 5 8283185 Press Enter to go into Setup Mode ic prefiere H Etherne st Rute de IP addr 172 38 1 78 no en set netmazk 255 255 040 008 Channel 1 I F Mode 4C Plow AA mote IP Adr none Port 808800 H 3 Disconn Mode 88 RUN UU UE Expert NK OUO itor Neepalive 45s RP cache timeout KH hange Setup B Server conf igurat 11 2 cha 6 Secur Factory defaults 8 Exit vitho hout save 3 Save and exit Your choice n z Type 1 and press ENTER to set up Channel 1 configuration This information appears Telnet 172 17 10 70 Connect Edit Terminal Help 7 factory defaults 8 exit without save 9 save and exit Baudrate caoeno I F Mode D I Flow 88 Port No TS C
3. Equivalency 0 0 B Number Interface IEEE 802 3 Outputs Relay contact type 26 Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide Appendix C900V2 Compatible Data Formats Appendix C900V2 Compatible Data Formats Table 13 Compatible Central Station Receiver Formats Compatible Receiver Formats s Radionics Radionic SIA Bell Receive r Model Modem s BFSK 103 110 3 1 lie II and amp 300 Checksum Illa baud x x Bosch Security Systems Inc 8 08 F01U087780 01 27 Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 9199 800 289 0096 2008 Bosch Security Systems Inc F01U087780 01 s WPP BOSCH
4. Protection 18 6 0 UL Standard 1610 and ULC S304 Intrusion System Installations 19 6 1 Protected Premises Control Panel without Digital Dialer Backup 19 6 2 Protected Premises Control Panel with Digital Dialer Backup 22 7 0 UL Standard 864 for Fire System Installations eere eere eren 23 8 0 Specifications ceeeeeeeeeeeenee 26 Appendix C900V2 Compatible Data Formats 27 Figures Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 Figure 11 Figure 12 Figure 13 Tables Table 1 Table 2 Table 3 Table 4 Table 5 Table 6 Table 7 Table 8 Table 9 Table 10 Table 11 Table 12 Table 13 Location of Major Components 4 Optional Mounting Plate 5 Attaching to Enclosure Door 5 C900V2 in AE2 Enclosure 5 Wiring to a DS7400Xi in the Same Enclosure thee rere 6 C900V2 Input Output and Power 7 RJ 11 Connector Wiring 7 C900V2 DIP Switches 8 C900V2 LED Locations 10 MAC Address Label Example 13 ARP Table seessseessssreesssesrnsreressseessere 14 C900V2 and Generic Control Panel in Separate Enclosures UL Standard 1610 with or
5. Remote System The Connect dialog box appears Host Name Port tenet TermType ka 00 Cancel a Inthe Host Name field type the IP address of the C900V2 In the Port field type 1 c Accept vt100 as the TermType field d Click Connect Bosch Security Systems Inc 8 08 FO1U087780 01 Conettix C900V2 Installation Guide 4 0 C900V2 Configuration Setup Instructions After a few seconds an error message AEN appears erial Nunber 5221484 MAC address 00 20 48 52 53 EC ress Enter to go into Setup Mode basic parameters jardware Ethernet futodetect IP addy 172 30 1 70 no gateway set netmask 255 255 600 000 Connect failed Security enabled public enabled enabled enabled enabled disabled nhanced Password is disabled e Could not open a connection to 172 17 10 70 Channel H 9 I F Mode c Flow 88 gem ne Fort mn CO Disconn Mode lush Mode 88 4 Click OK to clear the message The Telnet window appears again Channel laudrate 96808 I F Mode ic Flow 88 ort 180882 anota nur ER Rane eg Fort soe 5 Select Connect gt Remote System lush Mode 68 Expert CP Keepalive The Connect dialog box appears again WP cache tineout 600s hange Setup 0 Server configuration 1 Channel 1 configuration 2 Channel 2 configuration 5 Expert settings 6 Security Factory defaults 8 Exit without save 9 Save and exit Your choice Host Name f172
6. central station The C900V2 decodes the digital dialer message and sends the decoded signals by Ethernet connection to the Conettix D6600 or D6100i Communication Gateway Receiver referred to as the receiver When the receiver acknowledges receipt of the message the C900V2 sends an acknowledge message to the dialer This process maintains true end to end security The C900V2 has three modular connectors e TELCO connects to the PSTN e PANEL connects to a digital dialer e Ethernet connects to the network In Intercept Mode the C900V2 connects the digital dialer to a LAN or WAN In Fallback Mode the C900V2 connects the dialer to the PSTN which bypasses the C900V2 from the phone circuit The C900V2 stays in Intercept Mode when its CPU is working Output 1 open In Fallback Mode the C900V2 connects the dialer directly to the PSTN The C900V2 switches to Fallback Mode if there is a CPU or network failure 2 0 Installation Failure to follow these instructions can result in the system failing to transmit an alarm Bosch Security Systems Inc is not responsible for improperly installed tested or maintained devices Notify the central station and the local authority before installing the C900V2 in an existing system Disconnect all power to the control panel before installing the C900V2 3 g 2 1 Mounting The C900V2 is static sensitive Before handling the circuit board touch earth ground to dis
7. normal Repeat the previous step using 9999 as the port number 4 Type open IP ADDRESS 9999 and press ENTER for example open 172 17 10 70 9999 Bosch Security Systems Inc 8 08 F01U087780 01 15 Conettix C900V2 Installation Guide 4 0 C900V2 Configuration Setup Instructions 5 Press ENTER The Setup Mode information appears antronix UTS Snr 1281 167 U3 6 ress Enter to go into Setup Mode basic parameters ardware Ethernet flutodetect IP addr 172 17 10 70 no gateway set netmask 255 255 088 080 Channel 1 audrate 89688 I F Mode AC Flow 88 t 83801 connect Mode CH Disconn Mode 81 lush Mode 88 hange Setup Server configuration 1 Channel 1 configuration 7 factory defaults 8 exit without save 9 save and exit Your choice Continue with Section 4 5 3 Configuration Using Telnet 4 5 3 Configuration Using Telnet 1 Type 0 zero and press ENTER to set up the basic server configuration If the C900V2 was previously programmed with an IP address the address appears in parentheses 2 Type the IP address for example 190 200 128 219 and press ENTER Table9 Netmask Address Host Netmask Host Netmask Bits Bits 1 255 255 255 254 17 255 254 0 0 2 255 255 255 252 18 255 252 0 0 3 255 255 255 248 18 255 248 0 0 4 255 255 255 240 20 255 240 0 0 5 255 255 255 224 21 255 224 0 0 6 255 255 255 192 22 255 192 0 0 7 255 255 255 128 23 255 128 0 0 8 255 255
8. without Telephone Line 20 C900V2 and Generic Control Panel in Separate Enclosures UL Standard 864 EE 24 Power Terminal Functions H Control Panel and PSTN RJ 45 CONNECIOMS siai ea oir eere eoa Teal cd ee oret aet eve 7 Ethernet Connector Pins 8 Digital Dialer Protocol DIP Switches 1 through 4 and 10 uusss 9 DIP Switches 5 through 9 10 System LED Functions 11 Dialer LED Functions eeeeeeeeeeeeeeeeene 11 Dialer Interaction Forcing C900V2 into Fallback Mode eese 12 Netmask Address sese 16 Connection Sequence C900V2 and Generic Control Panel in Separate Enclosures UL Standard 1610 with or without Telephone Line 21 Connection Sequence C900V2 and Generic Control Panel in Separate Enclosures UL Standard 864 25 Specifications cesses 26 Compatible Central Station Receiver Revue 27 Bosch Security Systems Inc 8 08 FO1U087780 01 Conettix C900V2 Installation Guide Contents 1 0 Introduction The Conettix C900V2 Dialer Capture Ethernet Module referred to as the C900V2 links the digital dialer data output from a control panel to an Ethernet connection on a local area network LAN or wide area network WAN When the dialer sends a message the C900V2 simulates a public switched telephone network PSTN connection to the
9. you enable encryption on the C900V2 you must enable encryption on the D6680 with the same key 16 17 18 19 20 From the Change Setup menu type 6 and press ENTER This information appears of Telnet 172 30 1 31 Connect Edit Terminal Help Change Setup 8 Server configuration 1 Channel 1 configuration 2 Channel 2 configuration 5 Expert settings 6 Security 7 Factory defaults 8 Exit without save 9 Save and exit Disable SNMP N N Your choice 6 SNMP Community Name Disable Telnet Setup N N Disable TFTP Firmware Update N N Disable Port 77FEh N N Disable Web Server N N Disable ECHO ports V V Enable Encryption N Bj At the Disable SNMP prompt press ENTER to accept the default N At the SNMP Community Name prompt press ENTER to accept the default public At the Disable Telnet Setup prompt press ENTER to accept the default N At the Disable Port 77FEh prompt press ENTER to accept the default N Disabling both the telnet and port 77FE prevents you from accessing the set up menu for future changes 21 22 23 24 25 26 27 At the Disable Web Server prompt press ENTER to accept the default N At the Disable ECHO ports prompt press ENTER to accept the default Y At the Enable Encryption prompt type y and press ENTER At the Change keys prompt type y and press ENTER Type the key programme
10. 00V2 You must to Figure 5 install any other control panel in a t t ive the UL M The control panel s phone line monitor SE EE IN becomes inactive when the C900V2 intercepts the phone line between the telco service and the control panel If phone line monitoring is required use an external phone line monitor such as the Bosch Security Systems Inc DS7481 The loss of a network connection closes the Output 2 relay contact on the C900V2 You can connect this output to a 24 hour zone on the control panel 6 Bosch Security Systems Inc 8 08 FO1U087780 01 Conettix C900V2 Installation Guide 2 3 Input Functions The C900V2 has three inputs monitored by analog to digital A D converters e Input 1 IN1 Used as an end of line EOL supervised loop If input status reports are enabled by the receiver using the Conettix D6200 Programming Administration Software referred to as D6200 Software any voltage below 1 66 VDC is sent as a short circuit message to the D6600 Any voltage above 3 33 VDC is sent as an open circuit message Input 1 must be EOL terminated with a 10 k resistor Refer to the D6600 D6100i Computer Interface Manual P N 4998122703 for Event Messages to automation software e Input 2 IN2 Used for Intercept Inhibit If Input 2 rises above 5 5 VDC the C900V2 is immediately forced into Fallback Mode for at least 2 minutes Input 2 must go low for at least 5 seconds to be considered l
11. 04 Intrusion System Installations To install the C900V2 to comply with UL Standard 1610 Applications for Line Security formerly Grade AA and ULC S304 you must satisfy all requirements in this section 6 1 Protected Premises Control Panel without Digital Dialer Backup 1 Usethe D6200 Software to set the poll rate on the C900V2 For UL approved installations the maximum interval is 90 seconds to meet the requirement for polling supervision established by UL In most cases to get a polling supervision interval of 90 seconds set the Poll Rate to 75 and Retry to 13 Because of differences in packet transmission time latency within different networks the poll rate times vary Contact Technical Support at Bosch Security Systems Inc for assistance in establishing the latency time for the network on which you are installing the C900V2 iv 2 Set DIP Switch 7 to the OFF position to enable 75 second supervision signals the factory default Refer to Table 5 on page 10 for the functions of DIP Switches 5 through 9 3 Addatelnet password to the communications protocol of the C900V2 refer to Section 4 5 3 Configuration Using Telnet step 6 on page 16 Retain this password for future reference Refer to D6200 Software Operation and Installation Guide P N 4998154991 4 Program the control panel to send a daily test signal through the digital dialer iv This tests the connection from the co
12. 11 Set the shorting link on P3 to the H position Refer to Figure 12 on page 20 and Table 10 on page 21 for the proper connection sequence 19 Conettix C900V2 Installation Guide 6 0 UL Standard 1610 and ULC S304 Intrusion System Installations Figure 12 C900V2 and Generic Control Panel in Separate Enclosures UL Standard 1610 with or without Telephone Line 6 1 Optional telephone line 6 AE2 enclosure 2 C900V2 7 Host control panel 3 D110 Tamper Switch 8 Battery 4 LAN or WAN 9 AC transformer 5 Metal conduit no longer than 6 1 m 20 ft V indicates the connection sequence Refer to Table 10 20 Bosch Security Systems Inc 8 08 FO1U087780 01 Conettix C900V2 Installation Guide 6 0 UL Standard 1610 and ULC S304 Intrusion System Installations Table 10 Connection Sequence C900V2 and Generic Control Panel in Separate Enclosures UL Standard 1610 with or without Telephone Line Seq C900V2 Connection Control Panel Connection Other Connection 1 RJ 45 PANEL connector to RJ 45 connector telco dialer 2 RJ 45 ETHERNET to LAN or WAN connector 8 V terminal to 12 to 24 VDC common 4 Vt to 12 to 24 VDC output 5 Install an EOL resistor for the control panel across OUT2 L and OUT1 R 6 OUT2 L TO OUT1 L 7 OUT2 R TO OUT1 R 8 OUT1 R to C900V2 enclosure closed circuit tamper switch 9 C900V2 enclosure c
13. 17 1 0 70 d Port 9999 TermType vt 00 Cancel 6 This time change the Port field to 9999 accept the other fields and click Connect Continue with Section 4 5 3 Configuration Using Telnet on page 16 4 5 2 Starting Windows 2000 XP Telnet To do this procedure you must log in at an administrator privilege level The MAC address IP address gateway This message appears IP address and port number in this procedure are examples and are not the onec Edi Temi Hes same as those for your C900V2 ACOLA CoBox Snr 1365 146 U3 6 1 Select Start gt Run The Run dialog box appears Press Enter to go into Setup Mode xxx basic parameters Hardware Ethernet fiutodetect IP addr 172 617 618 676 gateway 255 255 255 686 netmi 2 Inthe Run dialog box type telnet and click OK 7 Press ENTER The Telnet window appears den H Command Prompt telnet You must press ENTER within five icrosoft R gt Windows 2800 lt TM Version 5 00 Build 2195 1 t i t t i seconds or the telnet session elnet Client Build 5 08 99203 1 disconnects scape Character is CTRL E icrosoft Telnet open 172 17 10 70 1 The Telnet window shows this information 3 Type open IP ADDRESS 1 and press ENTER where IP ADDRESS gt is the IP address of the C900V2 Type a space after open and after the IP address For example open 172 17 10 70 1 The connection fails the first time This is
14. 255 0 24 255 0 0 0 9 255 255 254 0 25 254 0 0 0 10 255 255 252 0 26 252 0 0 0 11 255 255 248 0 27 248 0 0 0 12 255 255 240 0 28 240 0 0 0 13 255 255 224 0 29 224 0 0 0 14 255 255 192 0 30 192 0 0 0 15 255 255 128 0 31 128 0 0 0 16 255 255 0 0 If you are using DHCP type 0 0 0 0 and press ENTER Refer to Section 4 1 Dynamic Host Configuration Protocol DHCP on page 13 3 Ifthe Gateway address is required type y press ENTER and then type the address and press ENTER If the Gateway address is not required or if you use DHCP type n and press ENTER This prompt appears Netmask Number of Bits for Host Part 8 default 88 If you are using DHCP this prompt appears Change DHCP device name gt 7 ND _ 5 If you do not want to assign or change the name press ENTER If you want to assign a name for this device for use on aLAN type y and press ENTER Type the name up to 16 characters and press ENTER If you do not enter a DHCP device name a default name of Cxxxxxx is used where xxxxxx is the last six digits of the MAC address The Gateway IP is required only if you are connecting to a WAN In a LAN the Gateway IP is usually not needed unless the Gateway IP of the PC is different from the Gateway to which the C900V2 is connected 4 If using DHCP press ENTER If not enter the number of bits that correspond to the netmask your network uses and press
15. 5 through 9 Switch State Function 5 ON Enable auto Fallback Mode after detecting an intercept error OFF Disable auto Fallback Mode after detecting an intercept error 6 ON Hang ups do not cause Fallback Mode OFF Third hang up without receiver ACK causes Fallback Mode 7 ON 240 sec poll OFF 75 sec poll 8 ON C900 sends initial handshake to panel after 6 sec dialing break OFF C900 sends initial handshake to panel after 1 sec dialing break 9 ON Enable Anti Replay Substitution OFF Disable Anti Replay Substitution If an error occurs in the Intercept Mode the C900V2 automatically returns falls back to the telco line If the receiver does not acknowledge a report intercepted by the C900V2 in the specified time the digital dialer hangs up and retries the message transmission The C900V2 switches to Fallback Mode based on the number of hang ups The time that elapses between polls from the C900V2 when it is idle not expecting a dialer acknowledgement s This DIP switch must be set to ON if the receiver is set up for NNC Mode Any error forces the C900V2 to switch Figure 9 C900V2 LED Locations to Fallback Mode phone line backup ee for 2 min the next time the control panel seizes the line if DIP Switch 5 is ON i DIP Switch 6 is OFF or both and if the control panel seizes the line within 2 min Intercept errors are always E reported to the receiver If the receive
16. C or hardware address of the C900V2 This address is hard coded into the C900V2 during its manufacture and cannot be changed This address is 6 bytes 12 digits long Figure 10 shows an example of a MAC address Bosch Security Systems Inc 8 08 F01U087780 01 Figure 10 MAC Address Label Example XP1001000 Q 2 u 8 t m 3ogu E EN Palent Pending The MAC address label is located on the top of the Ethernet connector Record this number for future reference 4 3 Getting an IP Address If you are using Dynamic Host Configuration Protocol DHCP you do not need an IP address If you are not using DHCP request an IP address for your C900V2 from your network administrator You might have to provide the MAC address An IP address is an identifier for a computer or device on a TCP IP network The IP address is a 32 bit numeric address written as four numbers separated by periods Each number can be zero to 255 for example 190 200 128 111 In an isolated network you can assign IP addresses at random if each one is unique Connecting a private network to the Internet requires registered IP addresses called Internet addresses to avoid duplication 4 4 Initial IP Address Assignment Using ARP EXE The C900V2 you are configuring and the PC used to configure it must both be on the same gateway the device that connects the LAN to the WAN to use telnet for configuration of the C900
17. Conettix C900V2 1 A 3 a BOSCH LIT 2004 f01000299842 Siren 4 E TN s e Pa wy r ern s e 5 Mi dt A E e Ze Dal ve as ie ar D ioe ER Installation Guide EN Dialer Capture Ethernet Module BOSCH Conettix C900V2 Installation Guide Trademarks Trademarks Altronix is a registered trademark of Altronix Corporation Phillips is a registered trademark of Phillips Screw Company in the United States and other countries Windows 98 Windows 2000 and Windows XP are registered trademarks of Microsoft Corporation in the United States and or other countries UL Listings and Approvals The Conettix C900V2 Dialer Capture Ethernet Module is UL Listed under the following standards e UL Central Station Burglary 1610 Encrypted Line Security e UL Commercial Fire Alarm Signaling 864 Primary e UL Police Station Burglar Alarm Units and Systems 365 e FCC Part 15 Radiated Conducted Emissions e CUL S304 M88 Central and Monitoring Station Burglar Alarm Units e C1076 Proprietary Burglar Alarm Units and Systems cUL installations approved for Level 3 Line Security when communicating over a packet switched data network PSDN Install according to ULC S302 Refer to the D6200 Software Operation and Installation Guide P N 4998154991 for information on how to prepare the D6600 or D6100i in your Monitoring Center to receive UL Listed communications from a Conettix C900V2 D
18. OFF ON ON OFF FBI Superfast DTMF 2300 Hz ACK Tone f ON OFF ON ON ON FBI Superfast DTMF 1400 Hz ACK Tone T ON ON OFF OFF OFF Pulse 3 1 3 1 Checksum 2300 Hz ACK Tone ON ON OFF OFF ON Pulse 3 1 3 1 Checksum 1400 Hz ACK Tone ON ON OFF ON OFF Pulse 4 2 Long 2300 Hz ACK Tone ON ON OFF ON ON Pulse 4 2 Long 1400 Hz ACK Tone ON ON ON OFF OFF SIA Bell 103 110 300 baud 2016 Hz ACK Tone ON ON ON OFF ON Reserved ON ON ON ON OFF ADT SIAT ON ON ON ON ON Reserved OFF OFF OFF OFF OFF Reserved OFF OFF OFF OFF ON Reserved OFF OFF OFF ON OFF Scancom 481 581 681 T t OFF OFF OFF ON ON Reserved OFF OFF ON OFF OFF Reserved OFF OFF ON OFF ON Reserved OFF OFF ON ON OFF Telim T OFF OFF ON ON ON Robofon T OFF ON OFF OFF OFF Reserved OFF ON OFF OFF ON Reserved OFF ON OFF ON OFF Reserved OFF ON OFF ON ON Reserved OFF ON ON OFF OFF SIA Bell 103 110 300 baud 2083 Hz ACK Tone t OFF ON ON OFF ON SIA V 21 110 300 baud t OFF ON ON ON OFF Seriee DTMF T OFF ON ON ON ON Seriee FSK T DTMF includes Contact ID High Speed and 4 2 Express T These formats have not been approved for UL 1610 t Requires firmware version 1 12 or higher Dialer Format of Host Alarm Panel Bosch Security Systems Inc 8 08 F01U087780 01 9 Conettix C900V2 Installation Guide 3 0 Setup Table 5 DIP Switches
19. Switches Pin Connection ij TX 2 TX 3 RX 6 RX 3 0 Setup 3 1 Setting P3 A shorting link on P3 selects the voltage and current applied to the alarm panel s telephone circuit to simulate the signal from a PSTN telephone exchange For most alarm panels set the shorting link to the H position short the middle and right pins of P3 The L position results in slightly lower power consumption for the C900V2 but some alarm panels might report a telephone line failure when dialing the C900V2 11 0 M Because the C900V2 emulates a phone N line and a digital receiver you must program the C900V2 to the format it For UL approved applications the shorting link must be set to the H position receives from the control panel DIP Switch positions 1 through 4 and 10 program the dialer format into the C900V2 Table 4 on page 9 lists the format programming for these DIP switches Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide 3 0 Setup Table 4 Digital Dialer Protocol DIP Switches 1 through 4 and 10 DIP Switches 10 1 2 3 4 ON OFF OFF OFF OFF Radionics Modem Ile and Modem Illa ON OFF OFF OFF ON Radionics Modem II ON OFF OFF ON OFF DTMF ON OFF OFF ON ON DTMF where dialer retransmits quickly ON OFF ON OFF OFF BFSK 2300Hz ACK Tone ON OFF ON OFF ON BFSK 1400Hz ACK Tone ON
20. V2 The gateway can be a router or a hub After you configure the C900V2 and assign it an IP address you can then use telnet to change configuration parameters from anywhere on the network Read this entire procedure before starting Ensure that power is applied to the C900V2 and the C900V2 is connected to the LAN or WAN through the Ethernet connector The following procedure shows how to use the ARP command to assign an IP address to the C900V2 13 Conettix C900V2 Installation Guide 4 0 C900V2 Configuration Setup Instructions The IP and MAC addresses in this procedure are examples and are not the same as those for your C900V2 1 Select Start gt Run The Run dialog box appears 2 Inthe Run dialog box type COMMAND and click OK A DOS window appears 2 MS DOS Prompt Cell al A Microsoft R gt Windows 98 CoCopyright Microsoft Corp 1981 1998 C NVINDOUS gt 3 Atthe DOS command line type arp S XXX XXX XXX XXX ZZ ZZ ZZ ZZ ZZ ZZ and press ENTER e XXX XXX XXX xxx is the IP address the network administrator assigned to the C900V2 e ZZ ZZ ZZ ZZ ZZ ZZ is the MAC address printed on the Ethernet connector label For example C WINDOWS gt arp s 172 17 10 70 00 20 4a 12 04 0e The program responds with a prompt to indicate that the address was accepted C WINDOWS gt arp s 172 17 10 70 00 20 4a 12 04 0e C WINDOWS gt _ The pr
21. charge any static electricity from your body Use a grounding strap while installing the circuit board Figure 1 Location of Major Components DCH AAA 1 RJ 45 phone jack to PSTN 2 RJ 45 phone jack to control panel 3 High and low voltage selector refer to Section 3 1 on page 8 4 DIP switch refer to Section 3 2 on page 8 5 RJ 45 Ethernet jack to LAN or WAN 6 Power terminal strip refer to Section 2 5 on page 7 7 Input and output wiring terminals refer to Sections 2 3 and 2 4 on page 7 8 Dialer and system LEDs refer to Section 3 3 on page 10 2 1 1 Use an optional mounting plate P N 40182 for mounting the C900V2 on the door of a control panel D8103 or a fire control panel enclosure D8109 You cannot use the D8108A Attack Resistant Enclosure Optional Mounting Plate Mounting a C900V2 in a control panel enclosure is approved by UL only when used with a DS7400Xi as shown in Figure 5 on page 6 For the following procedure refer to Figure 2 on page 5 1 Insert the top hook of the supplied top 1 and bottom plastic standoffs 2 into the mounting plate brackets 3 Refer to Detail A 2 Align the holes in the mounting brackets 3 and the plastic standoffs 1 and 2 Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide Contents 2 1 3 Separate Enclosure Mounting You can
22. ck 9 Set DIP Switch 6 to OFF so three hang ups cause fallback Any error forces the C900V2 to switch to Fallback Mode for 2 minutes the next time the alarm panel seizes the line if DIP Switch 5 is ON or DIP Switch 6 is OFF or both and the seizure occurs within 2 minutes Intercept errors are always reported to the receiver If the receiver does not acknowledge the signal in the programmed time the control panel digital dialer hangs up and retries the message 10 Set DIP Switch 9 to ON to enable Anti Substitution Anti Replay 11 Set the shorting link on P3 to the H position Refer to Figure 12 on page 20 and Table 10 on page 21 for the proper connection sequence Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide 7 0 UL Standard 864 for Fire System Installations 7 0 UL Standard 864 for Fire System Installations To install the C900V2 in compliance with UL 864 for Fire System Installations you must satisfy all requirements in this section You must install the system in accordance with NFPA 72 If the control panels are used for fire applications test according to NFPA 72 For UL Listed Fire Installations shared on premises communications equipment must be UL Listed for Information Technology Equipment Installation at the Protected Premises 1 Usethe D6200 Software to set the poll rate on the C900V2 For UL approved installations the maximu
23. d for the receiver and press ENTER The key is 16 bytes 32 characters long Enter the key using the 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 format At the Enable Enhanced Password prompt press ENTER to accept the default N Type 9 and press ENTER to save changes and exit the telnet session To confirm that the IP address is configured properly use the ping utility 17 Conettix C900V2 Installation Guide 5 0 Anti Substitution Protection 28 At the C gt prompt type ping lt IP Address gt and press ENTER Four reply messages are received confirming the C900V2 is communicating on the network Configuration of the C900V2 is complete 18 5 0 Anti Substitution Protection 1 Remove power from the C900V2 2 Set DIP Switch 9 to the ON position the factory default Refer to Section 3 2 Setting the DIP Switches on page 8 3 Apply power to the C900V2 After rebooting the C900V2 the unit exchanges numeric keys with the receiver and they become synchronized Once they are synchronized all subsequent communications sessions numerically validate the authenticity of the sender and receiver Each session generates an entirely new set of keys which invalidates the replay of authentic sessions Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide 6 0 UL Standard 1610 and ULC S304 Intrusion System Installations 6 0 UL Standard 1610 and ULC 3
24. e control panel This enables the control panel to annunciate a C900V2 CPU failure locally 6 Connect Output 2 from the C900V2 to a 24 hour zone on the control panel wj This enables the control panel to annunciate a network failure locally E You must use the C900V2 with a UL Listed Fire Alarm Control Unit or a UL Listed combination Fire Burglary Alarm Control Unit with an integral or UL Listed digital alarm communicator transmitter DACT Refer to the C900TTL E and C900V2 Compatibility Chart P N 4998141056 d If the C900V2 is installed in a separate enclosure you must locate the unit in the same room within 6 1 m 20 ft because the control equipment and the wiring must be enclosed in conduit or equivalently protected against mechanical injury Mounting a C900V2 in a control panel enclosure is approved by UL only when used with a DS 7400Xi as shown in Figure 5 on page 6 8 You must use the C900V2 with a UL Listed Power Supply such as Altronix AL300 ULXR Set DIP Switch 5 to OFF to disable Auto Fallback 10 Set DIP Switch 6 to ON to prevent fallback caused hang ups o Intercept errors are reported to the receiver If the receiver does not acknowledge a signal sent that was intercepted by the C900V2 in the programmed time the control panel digital dialer hangs up and retries the message transmission 11 Set DIP Switch 9 to ON to enable Anti S
25. he dialer hangs up an intercept error is generated The alternating LED also occurs when the line is seized but no transaction occurs for example the C900V2 is waiting for the dialer to return on hook This happens when the C900V2 returns to Intercept Mode or while the dialer seizes the line Table 7 Dialer LED Functions Color State Function None Off C900V2 is in permanent Fallback Mode due to a command or no power Green Solid C900V2 is in Intercept Mode and the dialer is on hook Flashing 5 Hz C900V2 is in Intercept Mode and the dialer is off hook Red Solid C900V2 is in Fallback Mode due to an error Intercept Inhibit or Override inputs or a command Flashing 5 Hz An off hook condition caused an intercept error Red Alternating 5 Hz The dialer is off hook but the last message was rejected due to a bad checksum or other Green logical error t f Auto Fallback After Error is enabled DIP Switch 5 ON the C900V2 connects the dialer to the phone line at the next line seizure If the dialer does not seize the line this condition terminates after two min If the dialer subsequently sends a valid message the LED returns to a blinking green status If the dialer hangs up an intercept error is generated The alternating LED also occurs when the line is seized but no transaction occurs for example the C900V2 is waiting for the dialer to return on hook This happens when the C900V2 returns to Inte
26. ialer Capture Ethernet Module Bosch Security Systems Inc 8 08 FO1U087780 01 Conettix C900V2 Installation Guide Contents Contents 1 0 Introduction ecce ecce eene eee eene 4 2 0 Installation 0 cv ore eroe eo enero 4 2 1 MOUNTING esee cete ee ee tree ege chan 4 2 1 1 Optional Mounting Plate 4 2 1 2 Attaching the Module to the Enclosure Door 5 2 1 3 Separate Enclosure Mounting 5 2 2 NIESEN RE 6 2 3 Input Functions sese n 2 4 Output FuncHons 7 2 5 Power Terminal Strip suus 7 2 6 Telephone Connections sessesssseeeee000ss0e 7 2 7 Ethernet Connection 8 3 0 SOU one E ESTE 8 3 1 Setting E 8 3 2 Setting the DIP Switches 8 3 3 LEDS entree eet eer tomer 10 3 3 1 System LED LED 1 sese 10 3 3 2 Dialer LED LED 2 10 3 5 Dialer Interaction esee 12 4 0 C900V2 Configuration Setup Instructions EE 13 4 1 Dynamic Host Configuration Protocol DHCP watch EE e ee 13 4 2 Identifying the MAC Hardware Address 13 4 3 Getting an IP Address 13 4 4 Initial IP Address Assignment Using ARP EXE EE 13 4 5 Using Telnet to Finish the Configuration 14 4 5 1 Starting Windows 98SE ME Telnet 14 4 5 2 Starting Windows 2000 XP Telnet 15 4 5 3 Configuration Using Telnet 16 5 0 Anti Substitution
27. ion Setup Instructions 4 1 Dynamic Host Configuration Protocol DHCP The receiver can communicate with a C900V2 that has an IP address dynamically assigned by a DHCP server on the network When using DHCP you must set the receiver to use the network naming convention NNC to identify accounts instead of using static IP addresses Devices in the field can have either a static IP address ora dynamic IP address The receiver uses the NNC number to identify the account instead of the IP address For devices having IP addresses assigned by a DHCP server e Set DIP Switch 9 on the C900V2 to ON e Enable NNC on the receiver Refer to the D6600 D6100i Computer Interface Manual P N 4998122702 e Set the Account Database in the D6200 Software to NNC Mode Refer to the D6200 Programming Software Operation and Installation Guide P N 4998154991 e Use the D6200 Software to enter the eight digit NNC number located on the label of the C900V2 into the Account Database Refer to the D6200 Programming Software Operation and Installation Guide P N 4998154991 e Configure network connections to communicate through a DHCP server e Setthe IP address of the C900V2 to 0 0 0 0 4 2 Identifying the MAC Hardware Address If you know the IP address of the configured C900V2 go to Section 4 5 Using Telnet to Finish the Configuration on page 14 You must program the IP address of the C900V2 The first step is to determine the MA
28. l 7 Battery 1 terminal to battery 2 terminal in series 8 Install an EOL resistor for the control panel across OUT2 L and OUT1 R 9 OUT2 L to OUT1 L 10 OUT2 R to OUT1 R 11 OUT1 R to C900V2 enclosure closed circuit tamper switch 12 C900V2 enclosure closed circuit tamper switch to control panel enclosure closed circuit tamper Switch 13 24 hour zone input common to Control panel enclosure closed circuit tamper switch 14 OUT2 L to 24 hour zone input 15 Battery negative input to Battery negative terminal 16 Battery positive input to Battery positive terminal 17 AC input AC transformer 18 AC input AC transformer NOTE The sequence numbers appear in the diagram in Figure 13 Bosch Security Systems Inc 8 08 F01U087780 01 25 Conettix C900V2 Installation Guide 8 0 Specifications 8 0 Specifications Table 12 Specifications Voltage Range Current Dimensions Operating Temperature Connectors Control Panel Telco LAN WAN Ethernet Cable Input Protocol from control panel Output Protocol to LAN WAN 12 VDC to 24 VDC nominal 280 mA maximum 17 8 cm x 11 4 cm 7 in X 4 5 in 0 C to 49 C 32 F to 120 F RJ 45 modular jack RJ 45 modular jack RJ 45 modular jack Category 3 or better 10 Base T or Category 5 or better 100 Base T unshielded twisted pair 100 m 328 ft maximum Refer to Table 4 on page 9 UDP IP packets Ringer
29. ler if the network communications path supervision fails You must use the C900V2 with a UL Listed Burglary Alarm Control Unit or a UL Listed combination Fire Burglary Alarm Control Unit with an integral or Listed digital alarm communicator transmitter DACT installed according to the manufacturer s instructions Refer to D6200 Software Operation and Installation Guide P N 4998154991 2 Set DIP Switch 7 to the ON position to enable 240 second supervision signals Refer to Table 5 on page 10 for the functions of DIP Switches 5 through 9 3 Add a telnet password to the communications protocol of the C900V2 refer to Section 4 5 3 Configuration Using Telnet step 6 on page 16 Retain this password for future reference 4 Program the control panel to send a daily test signal through the digital dialer This tests the connection from the control panel to the C900V2 5 Connect Output 1 from the C900V2 to a 24 hour zone on the control panel This tests the digital dialer if the C900V2 CPU fails 22 7 Install a tamper switch such as a D110 Tamper Switch available from Bosch Security Systems Inc on the control panel enclosure and connect it to a 24 hour zone on the control panel If you use a separate enclosure for the C900V2 install another tamper switch D110 on the enclosure and connect it to the same 24 hour zone 8 Set DIP Switch 5 to ON to enable Auto Fallba
30. losed circuit tamper switch to control panel enclosure closed circuit tamper Switch 10 24 hour zone input common to Control panel enclosure closed circuit tamper switch 11 OUT2 L to 24 hour zone input 12 Battery negative input to Battery negative terminal 13 Battery positive input to Battery positive terminal 14 AC input AC transformer 15 AC input AC transformer NOTE The sequence numbers appear in the diagram in Figure 12 7 V d The optional telephone line is for programming and diagnostics only Bosch Security Systems Inc 8 08 F01U087780 01 21 Conettix C900V2 Installation Guide 6 0 UL Standard 1610 and ULC S304 Intrusion System Installations 6 2 Protected Premises Control Panel with Digital Dialer Backup 1 Usethe D6200 Software to set the poll rate on the C900V2 For UL approved installations the maximum interval is 360 seconds to meet the requirement for polling supervision established by UL In most cases to get a polling supervision interval of 360 seconds set the Poll Rate to 240 and Retry to 13 Because of differences in packet transmission time latency within different networks the poll rate times vary Contact Technical Support at Bosch Security Systems Inc for assistance in establishing the latency time for the network on which you are installing the C900V2 6 Connect Output 2 from the C900V2 to a 24 our zone on the control panel M This tests the digital dia
31. m interval is 90 seconds to meet the requirement for polling supervision established by UL In most cases to get a polling supervision interval of 90 seconds set the Poll Rate to 75 and Retry to 13 For non UL approved installations the maximum interval is 300 seconds to meet the requirement for polling supervision set by NFPA Standard 72 Section 5 5 4 4 1 To get a polling supervision interval of 300 seconds set the Poll Rate to 240 and Retry to 13 Because of differences in packet transmission time latency within different networks the poll rate times vary Contact Technical Support at Bosch Security Systems Inc for help in establishing the latency time for the network on which you are installing the C900V2 Refer to D6200 Software Operation and Installation Guide P N 4998154991 iv 2 Set DIP Switch 7 to the OFF position to enable 75 second supervision signals Refer to Table 5 on page 10 for the functions of DIP Switches 5 through 9 iv 3 Addatelnet password to the communications protocol of the C900V2 refer to Section 4 5 3 Configuration Using Telnet step 6 on page 16 Retain the password for future reference Bosch Security Systems Inc 8 08 F01U087780 01 4 Program the control panel to send a daily test signal through the digital dialer This tests the connection from the control panel to the C900V2 5 Connect Output 1 from the C900V2 to a 24 hour zone on th
32. mount the C900V2 in a separate enclosure such as the AE2 Refer to Figure 4 Figure 2 Optional Mounting Plate 3 Place the top edge of the C900V2 4 under the standoff bracket of the top two standoffs 1 4 Insert two of the Phillips head screws provided 5 through the holes in the top standoffs 3 5 Lower the bottom edge of the module to rest against the ledge of the two bottom standoffs 2 6 Insert the other two Phillips head screws 5 into the bottom two mounting holes 6 on the C900V2 and through the bottom two plastic standoffs 2 and mounting bracket 3 7 Tighten the screws until the C900V2 is attached securely to the mounting plate 2 1 2 Attaching the Module to the Enclosure Door Refer to Figure 3 Figure3 Attaching to Enclosure Door 1 Slide the tabs 1 at the top of the mounting plate over the top lip of the enclosure door 2 2 Position the mounting plate on the side farthest from the door hinge Mount the enclosure on a vertical surface before you install the C900V2 because the C900V2 covers one of the mounting holes 9 1 Place the top edge of the C900V2 1 between the two slots 2 on the inside top of the enclosure 3 2 Insert the top hook of the top plastic standoffs 4 into the mounting brackets 5 on the back wall of the enclosure 6 showing a side view of the standoff in the mounting bracket 3 Align the bottom two mounting holes
33. ntrol panel to the C900V2 Bosch Security Systems Inc 8 08 F01U087780 01 5 Connect Output 1 from the C900V2 to a 24 hour zone on the control panel This enables the control panel to locally annunciate a C900V2 CPU failure iv 6 Connect Output 2 from the C900V2 to a 24 hour zone on the control panel wj This enables the control panel to locally annunciate a network failure You must use the C900V2 with a UL Listed Burglary Alarm Control Unit or a UL Listed combination Fire Burglary Alarm Control Unit with an integral or Listed digital alarm communicator transmitter DACT installed according to the manufacturer s instructions 7T Install a tamper switch such as a D110 Tamper Switch available from Bosch Security Systems Inc on the control panel enclosure and connect it to a 24 hour zone on the control panel If you use a separate enclosure for the C900V2 install another tamper switch D110 on the enclosure and connect it to the same 24 hour zone 8 Set DIP Switch 5 to OFF to disable Auto Fallback 9 Set DIP Switch 6 to ON to prevent fallback caused by hang ups Intercept errors are reported to the receiver If the receiver does not acknowledge a signal sent that was intercepted by the C900V2 in the programmed time the control panel digital dialer hangs up and retries the message transmission 10 Set DIP Switch 9 to ON to enable Anti Substitution Anti Replay
34. ogram does not indicate that the operation was performed properly The only indication is the absence of an error message 4 Verify that you entered the IP address correctly Type arp g and press ENTER This command displays the IP address 172 17 10 70 temporarily linked to MAC address 00 20 4a 12 04 0e as shown in Figure 11 The temporary link shows a static entry 14 Figure 11 ARP Table ex e WINNT system32 cmd exe WINNT gt arp g Interface 8 8 8 8 on Interface 6x1600004 Internet fiddress hysical Address Type 66 26 4a 12 04 Ge static 172 17 18 78 WINNT gt The network uses this table to identify devices and to route signals The number of devices and other types static and dynamic as shown in the example depends on the network and the number and type of devices with which this PC communicates Identify the MAC address of the device you are installing and verify that it now has an IP address linked to it 4 5 Using Telnet to Finish the Configuration Use the telnet program to configure the C900V2 The procedure for Windows 98SE ME is different from the procedure for Windows 2000 and Windows XP 4 5 1 Starting Windows 98SE ME Telnet 1 Select Start gt Run The Run dialog box appears 2 Inthe Run dialog box type telnet and press ENTER The Telnet application window appears olf Telnet None x Connect Edit Terminal Help 3 Select Connect 2
35. onnectMode CC ic x Your choice 1 Hardware Ethernet Rutodetect IP addr 172 017 010 070 gateway 255 255 255 000 netmask 255 255 006 666 JOOCOOOOOOOOOOOO OE pl 4 es K EKER Baudrate 69666 UE Hode 4C Flow 66 Port 87788 Datagram Type oe Pack Cntr1 Change Setup 8 Server configuration 1 Channel 1 configuration 7 factory defaults 8 exit without save Your choice 9 save and exit If the default value displayed in your Telnet window does not match the value listed in any of the steps below type the correct value and press ENTER Bosch Security Systems Inc 8 08 F01U087780 01 At the Baud Rate prompt press ENTER to accept the default 9600 At the I F Mode prompt press ENTER to accept the default 4C At the Flow prompt press ENTER to accept the default 00 Type a unique Port Number for the LAN to which the C900V2 is connected and press ENTER Atthe ConnectMode prompt press ENTER to accept the default CC Atthe Datagram Type prompt type 01 and press ENTER Atthe IP addr prompt type the remote IP address used for the receiver to which the C900V2 reports and press ENTER Enter the remote IP address using 000 000 000 000 format 15 C900V2 Configuration Setup Instructions Type the Port Number for the receiver and press ENTER If you want to enable encryption continue with the next step If not go to step 27 If
36. ow If Input 2 is not used allow it to remain disconnected e Input 3 IN3 Used for Intercept Override If Input 3 rises above 5 5 VDC for 5 seconds the C900V2 enters Fallback Mode If Input 3 goes low the C900V2 returns to Intercept Mode If this input is connected to a ground start relay output the C900V2 remains in Intercept Mode except to allow the dialer to dial Input 3 cannot force Intercept Mode if the C900V2 is in Fallback Mode because of an error a command or a high signal at Input 2 If this input is not used allow it to remain disconnected e Output 2 OUT2 Active open when the receiver works properly and closed when the receiver does not respond to or acknowledge a message sent from the C900V2 Connect Output 2 from the C900V2 to a 24 hour zone on the control panel This 24 Hour Zone Alarm Report enables the digital dialer if used to indicate or sound a failure if the network communications path fails e Output 3 OUT3 Active open when the C900V2 is in Intercept Mode e Output 4 OUT4 Controlled by a command from the D6200 Software or receiver The default is open 2 5 Power Terminal Strip Table 1 Power Terminal Functions Terminal Description V Connect regulated 12 to 24 VDC power to this terminal and the V terminal This power can be supplied by a separate power supply or auxiliary power from the control panel V 12 to 24 VDC return Ge Connect to ear
37. r does not acknowledge a signal intercepted by the C900V2 in the specified time the control panel digital dialer hangs up and tries to send the message again 3 3 LEDs The C900V2 has two dual color status LEDs the system LED and the dialer LED 1 System LED The Ethernet connector also includes two LEDs 2 Dialer LED that indicate the status of the network connection 3 Ethernet connector LEDs The right LED lights or flashes when there is a valid connection to the network 3 3 1 System LED LED 1 The system LED indicates the status of the receiver and the C900V2 itself Refer to Table 6 on page 11 3 3 2 Dialer LED LED 2 The dialer LED indicates the status of the digital dialer interface Refer to Table 7 on page 11 10 Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide 3 0 Setup Table 6 System LED Functions Color State Function None Off No power Green Solid C900V2 failed Flashing 5 Hz The receiver is responding normally Red Solid C900V2 failed Flashing 5 Hz The receiver is not responding Flashing 1 flash ROM checksum error Repeating 2 flashes RAM test error Code Red Alternating 5 Hz The dialer is off hook but the last message was rejected because of a bad checksum or Green other logical error 1 If the dialer subsequently sends a valid message the LED returns to a blinking green status If t
38. rcept Mode or while the dialer seizes the line Bosch Security Systems Inc 8 08 F01U087780 01 11 Conettix C900V2 Installation Guide 3 0 Setup 3 4 Fallback Mode 3 5 Dialer Interaction In fallback operation the C900V2 connects the Table 8 shows the conditions causing the C900V2 PSTN directly to the dialer bypassing itself from to change to Fallback Mode The C900V2 returns the phone circuit Intercept Mode is maintained to Intercept Mode only when all conditions in the only if the C900V2 processor operates and there Intercept Mode Restored column are met are no errors Fallback Mode is ensured if a CPU lockup occurs Table8 Dialer Interaction Forcing C900V2 into Fallback Mode Condition CPU fails Receiver fails Receiver does not respond to last message Intercept Disable Command Intercept Error Switch to Fallback command Fallback Mode Occurs Intercept Mode Restored Immediately C900V2 restart Immediately Link restored Dialer goes off hook disconnected Link restored On receipt of the command Intercept Enable command If Fallback after intercept error is enabled the After two minutes dialer goes off hook within two minutes of the error On receipt One hour or at receipt of Intercept Enable command 12 Bosch Security Systems Inc 8 08 F01U087780 01 Conettix C900V2 Installation Guide 4 0 C900V2 Configuration Setup Instructions 4 0 C900V2 Configurat
39. th ground wj You cannot use Inputs 1 2 and 3 for UL 2 6 Telephone Connections Use two of the RJ 45 telephone connectors to connect to the control panel and to the PSTN The connector pins are identified in Table 2 and Figure 7 Table 2 Control Panel and PSTN RJ 45 N Fire Listing You can use the inputs for Connectors other purposes Figure 6 C900V2 Input Output and Power Ge OV NONN SNM NM ECH d Li OV OUT4 OUT3 OUT2 OUT1 IN3 IN20VIN1 V 5 R 8 R1 2 4 Output Functions The C900V2 has four relay contact outputs e Output 1 OUT1 Active open when the CPU works properly If the CPU fails or loses power Output 1 closes Connect Output 1 from the C900V2 to a 24 hour zone on the control panel This 24 Hour Zone Alarm report enables the digital dialer if used to indicate or sound a failure if the C900V2 CPU fails Bosch Security Systems Inc 8 08 F01U087780 01 Figure 7 RJ 11 Connector Wiring QN SSS Conettix C900V2 Installation Guide 3 0 Setup 2 7 Ethernet Connection One of the RJ 45 jacks connects the C900V2 to the Ethernet Network LAN or WAN The connector pins are listed in Table 3 Table 3 Ethernet Connector Pins 3 2 Setting the DIP Switches A ten position DIP switch programs the C900V2 The programming depends on the application and dialer format of the control panel connected to the Figure 8 C900V2 DIP
40. ubstitution Anti Replay 12 Set the shorting link on P3 to the H position Refer to Figure 13 on page 24 and Table 11 on page 25 for the proper connection sequence 23 Conettix C900V2 Installation Guide 7 0 UL Standard 864 for Fire System Installations Figure 13 C900V2 and Generic Control Panel in Separate Enclosures UL Standard 864 1 Optional telephone line 7 Host control panel 2 C900V2 8 Battery 3 D110 Tamper Switch 9 ACtransformer 4 LAN or WAN 10 Battery 5 Metal conduit no longer than 6 1 m 20 ft 11 UL Listed power supply such as Altronix 6 AE2 enclosure AL300 ULXR in separate enclosure indicates the connection sequence Refer to Table 11 24 Bosch Security Systems Inc 8 08 FO1U087780 01 Conettix C900V2 Installation Guide 7 0 UL Standard 864 for Fire System Installations Table 11 Connection Sequence C900V2 and Generic Control Panel in Separate Enclosures UL Standard 864 seq C900V2 Connection Control Panel Connection Other Connection 1 RJ 45 PANEL connector to RJ 45 connector telco dialer 2 RJ 45 ETHERNET connector to LAN or WAN 3 V terminal to 12 to 24 VDC common 4 V to 12 to 24 VDC output 5 Power supply BAT input to battery 1 terminal 6 Power supply BAT input to battery 2 termina
Download Pdf Manuals
Related Search
Related Contents
Tanaka TED-210 User's Manual Touch and Go - maxx About Netviewer Support E3NW-ECT EtherCAT Digital Sensor Communication Unit Mitsubishi Electronics 2033C Power Supply User Manual つなぎかたガイド - 121ware.com PuntoBravo - MTR+ Vertriebs Panasonic DMC-LX7K compact camera Copyright © All rights reserved.
Failed to retrieve file