Home
American Standard 2000.10X Indoor Furnishings User Manual
Contents
1. 6 to complete faucet mounting SS COLLAR ON S MOUNTING NUT 2 POP UP DRAIN m Remove CLEAR PLASTIC COVER 1 m Remove CARDBOARD SPACER 2 from under DRAIN POP UP 3 m Tighten TAILPIECE 4 on DRAIN BODY before installing DRAIN BODY Fig B 3 REMOVE FLANGE E Thread FLANGE 1 counter clockwise and remove FLANGE 1 and FOAM GASKET 2 from drain body Fig A E Thread LOCKNUT 3 clockwise to bottom of drain body Push GASKET 4 down against LOCKNUT 3 Fig B INSTALL DRAIN FROM BELOW FIXTURE m From under side of SINK install DRAIN BODY 1 up through drain outlet Note No plumber s putty or caulk is required The CABLE ATTACHMENT POINT 2 must face towards the rear of the SINK E Install FOAM GASKET 3 and FLANGE 4 onto drain body from above SINK and tighten FLANGE 4 firmly gm Check DRAIN FLANGE in SINK to ensure that WHITE FOAM GASKET 3 is fully compressed and not visible Fig A m POP UP KNOB 1 must be fully down Fig B AY a ss Wi REAR OF SINK WHITE FOAM GASKET NOT VISIBLE m Tighten LOCKNUT 1 firmly with Adjustable Wrench or Channel Locks DRAIN FLANGE M968760 Rev 1 3 F ATTACH CABLE CONNECTOR Thread CABLE CONNECTOR 1 clockwise onto DRAIN BODY CONNECTION 2 and hand tighten Fig A Your new POP UP DRAIN installation is now complete Fig B Note Tailpeice on pop up drain is 1 1 4 O D Fig B CHECK OP
2. Americam Standard Installation Instructions CHAMIX 2000 10X Centerset Lavatory Faucet with 2000 16X Speed Connect Drain Congratulations on purchasing your American Standard faucet with Speed Connect drain a feature found only on American Standard faucets Certified to comply with ANSI A112 18 1 Speed Connect Drain M968760 Rev 1 3 e Fewer parts installs in less time e Never needs adjustment e Guaranteed to seal properly the first time every time Your new American Standard faucet is designed to work only with the Speed Connect drain Heplful tips for removing your current drain can be found in the Troubleshooting section of these instructions To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Recommended tools NY Qe eS Screwdriver Channel Locks INSTALL FAUCET BRST iiei before beginning Seat SEAL 1 into under side of FAUCET BASE 2 Feed FAUCET SUPPLIES 3 MOUNTING STUD 4 and DRAIN CABLE ASSEMBLY 8 through ESCUTCHEON 9 optional and the mounting hole of lavatory or mounting surface Fig A From below push GASKET 7 and RETAINING WASHER 5 onto MOUNTING STUD 4 Secure Faucet with MOUNTING NUT 6 pulling faucet to front of sink so SUPPLIES 3 rests against e Before final tightening make sure collar on MOUNTING NUT 6 is seated into RETAINING WASHER 5 Fig B Adjust Faucet so that it is centered Tighten MOUNTING NUT
3. ERATION OF POP UP Operate LIFT KNOB 1 to verify that STOPPER 2 opens and closes Note If STOPPER 2 does not open and close properly then refer to the troubleshooting section of these instructions 9 MAKE WATER SUPPLY AND WASTE CONNECTIONS Connect FLEXIBLE SUPPLIES 1 2 directly to wall supplies Connection on fitting supplies are 3 8 compression Connect left SUPPLY 1 to Hot Marked with a Red Band and right supply to COLD 2 wall supply Faucet supplies are 20 long from faucet base Note If additional supply length is required installer must purchase additional parts separately Important If SUPPLY HOSES 1 2 are to long loop as illustrated to avoid kinking Connect 1 1 4 O D tailpiece on POP UP DRAIN to n waste outlet Ox 20 BLUE BAND 3 8 COMPRESSION M968760 Rev 1 3 1 0 TEST INSTALLED FITTING With HANDLE 1 in OFF position turn on WATER SUPPLIES 2 and check all connections for leaks Ei Remove AERATOR 3 Operate HANDLE 1 to flush water lines thoroughly Replace AERATOR 3 CHECK DRAIN CONNECTIONS Operate POP UP KNOB 4 and fill lavatory with water Check that DRAIN STOPPER 5 makes a good seal and retains water in SINK If DRAIN STOPPER 5 does not seal properly please refer to Troubleshooting section in these instructions Release POP UP KNOB 4 down and check all drain connections and P trap for leaks Tighten if necessary aii SERVICE IF FAUCE
4. OTH WITH A COARSE SURFACE M968760 Rev 1 3 Speed Connect Drain Troubleshooting Guide If sink does not hold water even though Stopper is in the down position e Follow CABLE ADJUSTMENT PROCEDURE If Soppar does not raise up fully or sink drains too slowly e Follow CABLE ADJUSTMENT PROCEDURE If you need to remove the Stopper e Follow STOPPER REMOVAL PROCEDURE If you would like the ability to remove your Stopper simply by lifting it out of the drain e Follow STOPPER INSTALLATION PROCEDURE for Unlocked mode CABLE ADJUSTMENT PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam in the illustration Fig B Use a small screwdriver to rotate the Cam in the clockwise direction as far as it will go At this point the Stopper should be in the UP position Fig B C Push DOWN on the Lift Knob to make sure it is fully down Fig C Re attach the Cable to the Drain Body Connection 2 by threading the Cable Connector 1 clockwise onto the Drain Body Connection 2 and hand tighten Fig A Fig B f Fig C STOPPER REMOVAL PROCEDURE Disconnect the Cable from the Drain by threading the Cable Connector 1 counter clockwise Fig A Look at the area on the Drain Body where the Cable was attached and locate the component labeled as Cam and Ca
5. T DRIPS HOT LIMIT SAFETY STOP m If faucet drips operate handle several times from By restricting handle rotation and limiting the amount of hot water allowed to mix with the cold the HOT LIMIT SAFETY E Clogged CARTRIDGE inlets may cause reduced flow off to on Do not apply excessive force STOP reduces risk of accidental scalding To set the maximum in full on hot or cold To clean inlets first turn off hot water temperature of your faucets all you need water supply then to do is adjust the setting on the HOT LIMIT SAFETY STOP m Remove HANDLE 1 CAP 2 SCREWS 3 and Remove necessary trim parts Use a flat blade screwdriver or CARTRIDGE 4 Clean inlets and MANIFOLD 5 pull forward with your fingers to rotate red HOT LIMIT SAFETY m Reassemble CARTRIDGE 4 alternately tightening STOP Follow Step A or B to adjust max min discharge temperature O being the hottest to 7 the coldest e ae Replace CAP 2 and HANDLE 1 temperature setting aA ADJUSTMENT WHEN POINTER ON WATER IS TOO HOT A HOT LIMIT STOP PRY RED RING FORWARD AND ROTATE COUNTER B CLOCKWISE ONE CLICK ADJUSTMENT WHEN WATER IS TOO COLD B PRY RED RING FORWARD AND ROTATE CLOCKWISE RED RING HOT LIMIT SAFETY STOP 1 2 CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CL
6. de Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig H To install the stopper in Unlocked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the front of the Sink and the American Standard logo is facing rear Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig H Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J Y LOOP TOWARD FRONT OF SINK Re install the Cam Cap making sure the guide teeth are facing Cr outward If the Cam Cap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Unlocked Mode Troublingshooting Guide to complete installation Stopper will be in Unlocked mode and removable INSTALL CAM CAP M968760 Rev 1 3
7. m Cap in the illustration Fig B Use fingers or small screwdriver under either side of the Cam Cap to pry it out from the Drain Fig D Remove the Cam by pulling it straight out while wiggling gently to loosen the Rubber Seal Fig E The Stopper can now be removed by lifting it out of the Drain Fig F REMOVE CAM CAP M968760 Rev 1 3 STOPPER INSTALLATION PROCEDURE The Stopper can be installed two ways Locked Mode Stopper cannot be removed or Unlock Mode Stopper is removable Locked Mode Look at the Plastic Loop at the bottom of the Stopper and notice that the Loop is on one side of the Stopper Fig G To install the stopper in Locked mode insert the Stopper into the Drain so that the Plastic Loop is facing toward the rear of the Sink and the American Standard logo is facing front Rotate Stopper slightly if necessary so that the Stopper slides all the way down Fig G Re install the Cam into the Drain rotating the Cam if necessary to make sure it is fully inserted Fig J Loop TOWARD REAR OF SINK Re install the Cam Cap making sure the guide teeth are facing Cy outward If the Cam Gap does not snap into place then rotate DRAIN the Cam to make sure it is fully inserted Fig K Re attach Cable See CABLE ADJUSTMENT PROCEDURE in Locked Mode Troubling Shooting Guide to complete installation Stopper will be Vandal Proof in Locked mode and not be removable Unlocked Mo
Download Pdf Manuals
Related Search
Related Contents
2. Primeira utilização do Tablet PC hi-Fun 13325 micronair: AU5000LD Samsung PE55C Vartotojo vadovas Revue de presse complète Subwoofer Ativo Copyright © All rights reserved.
Failed to retrieve file