Home
Abus Outdoor motion detector PIR Specifications
Contents
1. AUTOMATIC MODE flick the internal wall switch circuit breaker OFF ON within 1 second The lamp will extinguish and the unit will return to normal automatic operation SUNSET SWITCH COURTESY LIGHT MODE This unit incorporates a SUNSET SWITCH MODE designed to automatically activate the COURTESY LIGHT at dusk The unit will remain on at a convenient DIM setting 1 95 for a period of time set by the user 1 8 hours each night To enable SUNSET SWITCH MODE simply e Set the SUNSET TIMER adjustment knob as required 1 8 hours e Set the DIM CONTROL adjustment knob to any other setting other than 0 fully anti clockwise At Sunset each evening the COURTESY LIGHT will illuminate to a user defined low level dimmer setting between 1 and 95 of maximum brightness for the set time between 1 and 8 hours Should movement be detected by the sensor when the COURTESY LIGHT is active the light will go to full brightness for the period set by the PIR TIMER after which it will drop back down to the low level DIM setting After the SUNSET TIMER period has elapsed the lamp will extinguish and the unit will resume normal operation responding to movement as required Note that SUNSET SWITCH MODE will NOT reset to AUTOMATIC MODE at dawn it will repeat each night until reset by the user To disable the SUNSET SWITCH MODE simply set the DIM CONTROL to 0 fully anti clockwise Clipsal Australia Pty Ltd 11 of 20 754HB2 1 80 60 60W Se
2. Instructions 9 0 Troubleshooting PROBLEM Lamp stays ON all the time at night PIR keeps activating for no reason at random PIR sensor will not operate at all The PIR sensor will not operate at night Unit activates during the daytime PIR coverage is poor sporadic Detection range varies from day to day 16 of 20 SOLUTION The unit may be suffering from false activation Cover the sensor lens completely with a thick cloth This will prevent the sensor from seeing anything If the unit now switches off after the set time duration and does not re activate this indicates that the problem was caused by false activation The problem may be solved by slightly adjusting the direction angle of the sensor head see previous section You may not be allowing the unit time to complete its warm up period Stand well out of the detection range and wait the warm up period should never exceed five minutes Occasionally winds may activate the sensor Sometimes passages between buildings etc can cause a wind tunnel effect Ensure the unit is not positioned so as to allow detection of cars people using public thoroughfares adjacent to your property Check that the power is switched ON at the circuit breaker internal wall switch Turn OFF the power to the unit and check the wiring connections as per the diagram see previous section F Ensure no connections are loose Check the lamp If the
3. Sensor Lens 1 The unit is supplied with a lens mask which allows the option to reduce the range of the sensor 2 The lens mask simply clicks over the sensor When fitting ensure that your chosen option is facing forwards The engraved arrow indicates the front of the sensor 3 Ensure that the arrow marked on the lens mask is lined up with the arrow on the sensor This will then give an indication of the front of the detection area see Diagram H 4 Engraving on the lens mask indicates the effect on the detection range each segment will have These are 2m 4m 8m or 12m 5 Ifno segments are removed then the sensor WILL NOT detect The desired range can be achieved by carefully removing the segments then repeating the walk test after each segment has been removed until the desired detection area is achieved 10 of 20 Clipsal Australia Pty Ltd 754HB2 180 60 60W Security Twinspot Installation Instructions 3 5 Special Functions MANUAL OVERRIDE MODE The light can be switched on for longer time periods by use of the MANUAL OVERRIDE MODE The light can be activated AT NIGHT by using the internal wall switch circuit breaker Switch the internal wall switch circuit breaker OFF ON within 2 seconds The unit will now illuminate continuously OVERRIDE ON and will remain ON until MANUAL OVERRIDE MODE is cancelled or until dawn the following day whichever comes first To cancel MANUAL OVERRIDE MODE and switch the unit back into
4. lamp has failed replace Ensure that the lamp is seated correctly in the lampholder The level of ambient light in the area may be too bright to allow operation at the current DUSK setting During the hours of darkness adjust the DUSK control slowly clockwise until the lamp illuminates Refer to previous section for more details The level of ambient light in the area may be too dark for the current DUSK setting During daylight adjust the DUSK control slightly anti clockwise When the lamp extinguishes enter the detection area If the PIR still activates the setting is still too high Repeat the above procedure until the PIR does not activate when you enter the detection area Refer to previous section for more details Unit may be poorly located See previous section Selecting The Location and re locate the unit PIR sensors are influenced by climatic conditions The colder the ambient temperature the more effective the sensor will be You may need to make seasonal adjustments to the sensor head position to ensure trouble free operation all year round Clipsal Australia Pty Ltd 754HB2 180 60 60W Security Twinspot Installation Instructions 10 0 Technical Specifications Maximum Switchable Load Watts Conductors Required 12 metres Rated Detection Range 12 metres Field of View 180 User Adjustable Timer Delay Range 5 Seconds to 5 Minutes User Adjustable Sunset Switch Time Delay Range 1 Hour to 8 Hours U
5. lamp will extinguish Try to remain outside the detection area during the warm up period 5 Walk across the detection area approximately five metres from the unit As you cross a detection zone the lamp will illuminate Now stand still until the lamp extinguishes this should take approximately five seconds 6 Start moving again As you cross each zone the lamp will illuminate Repeat the above walking at various distances and angles to the unit This will help you to establish the detection pattern 7 The units sensor module can be adjusted horizontally from left to right If the detection area is too small for your requirements try turning the sensor head This can increase the coverage distance or will reduce the range should a smaller coverage area be required see Diagram G to see how to adjust the floodlight beam to suit 8 of 20 Clipsal Australia Pty Ltd 754HB2 180 60 60W Security Twinspot Installation Instructions 3 2 Adjustment Knobs PIR TIMER If the unit is set to AUTOMATIC MODE the PIR TIMER setting controls how long the unit remains illuminated after motion has f been detected and after all motion has ceased The minimum time fully anti clockwise is approximately 5 seconds whilst We the maximum time fully clockwise is approximately 5 minutes Set the control to the desired setting between these limits SUNSET TIMER If the unit is set in SUNSET SWITCH MODE the SUNSET TIMER setting
6. 40 Passive Infrared Outdoor Motion Detector Complete with Single 60W G9 High Efficiency Halogen Spotlight 60W Security Twinspot 754HS2 140 60 140 Passive Infrared Outdoor Motion Detector Complete with Twin 60W G9 High Efficiency Halogen Spotlights 150W Security Floodlight d rm 80 150 180 Passive Infrared Outdoor Motion Detector Complete with 150W R7s Linear Halogen Floodlight r 300W Security Floodlight 754HF1 180 300 180 Passive Infrared Outdoor Motion Detector Complete with 300W R7s Linear Halogen Floodlight 60W Security Spotlight 754HB1 180 60 180 Passive Infrared Outdoor Motion Detector Complete with Single 60W G9 High Efficiency Halogen Spotlight 60W Security Twinspot 754HB2 180 60 180 Passive Infrared Outdoor Motion Detector Complete with Twin 60W G9 High Efficiency Halogen Spotlights Clipsal Australia Pty Ltd A member of Schneider Electric Contact us clipsal com feedback National Customer Care Enquiries Tel 1300 2025 25 Fax 1300 2025 56 Clipsal Australia Pty Ltd reserves the right to change specifications modify designs and discontinue items without incurring obligation and whilst every effort is made to ensure that descriptions specifications and other information in this catalogue are correct no warranty is given in respect thereof and the company shall not be liable for any error therein Clipsal Australia Pty Ltd The identified trademarks and copyrights are the property of Clipsal Au
7. F CLIPSAL by Schneider Electric 60W Security Twinspot Installation Instructions INFRASCAN Please leave these instructions at the installation site 754HB2 1 80 60 60W Security Twinspot Installation Instructions 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 2 of 20 D te Le IT E 3 Wel PES EE 3 1 2 Wireless Alarm Upgrade WW icesncedececconeecesdeondeneenncecnace tetedsasceeneseennuecins 4 Installation Procedure uegegeegekegueebeeeege i orenian 5 2 1 Selecting a Locatii ssie 5 2 2 Mounting the RU EE 6 2 3 Electrical CONMECIONS seiscasessais penusinnasane dice taendemasingmenyshienusumiaaersabentaa 6 2 4 Halogen Lamp Replacement uk 7 Commissioning Proced re siiiicsnnisssncenonsosnssnannnntexvernsddaxenvonsennsnnesnostenndebaas 8 3 1 Walk Testing bProcedure ee EEEEEN 8 3 2 Adjustment MODS jcentscencsseeseccastisnaratvesiadsscapdastestesandenetennseselannennceaatan 9 3 3 Setting up for Automatic Operation ccccccccesssseseeeeeeeeeneeeeeeees 10 3 4 Masking the Sensor Lens ccjeseccesssvasiennpescacssenacaetieceeacaseghgeoonetnteciies 10 3 5 Special reeL LE 11 Detection Range Setting Controls scssssesseeseeeeeeeeeeeeeeeeeeeeeeeees 12 Installation Diagrain ssiiscismectssaticsiulacttanranccanwescdiauscdauiraewdeeneatearamsenwbancund 13 Conneccion DIGGIN E 14 Angle Adjustment sieve renseienctnncnerienicwinniadiesimmmiwianeinnindmuevuenutinnenenieowbamednie 15 Lens MASKI
8. HB2 1 80 60 60W Security Twinspot Installation Instructions 3 3 Setting up for Automatic Operation When walk tests are complete the unit can be switched to automatic operation 2 The PIR TIMER setting controls how long the unit remains illuminated following activation and after all motion ceases The minimum time fully anti clockwise is approx 5 seconds whilst the maximum time fully clockwise is approximately five minutes Set the control to the desired setting between these limits 3 The LUX control determines the level of darkness required for the unit to start operating The setting is best achieved by the procedure below e Set the LUX control knob fully anti clockwise The unit will now start operating at dusk If you require the light to activate earlier wait until the ambient light level reaches the level of darkness at which you wish the lamp to become operative SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates Leave the control set at this point e At this position the unit should become operative at approximately the same level of darkness each evening Observe the operation of the unit If the unit is starting to operate too early i e when it is quite light adjust the control slightly anti clockwise If the unit starts to operate too late i e dusk adjust the control slightly clockwise e Continue to adjust until the unit operates as desired 3 4 Masking the
9. NG DISgESa xeesesgerbeu e eseetekkeuerEu dE KEREN ENNER 15 Troubleshooting E 16 Ternes gege Geet nnmnnn nnna 17 VUE ICT 1 18 RE Ile Uu E 18 Wl 19 Prod ct le LE 20 Clipsal Australia Pty Ltd 754HB2 180 60 60W Security Twinspot Installation Instructions 1 0 Introduction Thank you for purchasing the 754HB2 180 60 Outdoor Infrascan Motion Detector The Motion Detector unit utilises passive infrared technology to detect heat radiation of moving human bodies Upon detection the spotlights will illuminate for a user determined time period An integrated daylight sensor ensures night only operation The spotlights included with this model feature an Adjustable Beam allowing the light to be focussed in a spot or dispersed to illuminate a larger area In addition to operating as a motion detector this product also incorporates a Sunset Switch function allowing lighting to come on at dusk for a user defined period of time The unit also features a Courtesy Light function Dimming technology incorporated within the unit allows lighting to be activated at dusk to a dim level set by the user welcoming visitors and guests When the unit detects movement lighting will increase to full brightness and return to the set dimming level when the timer expires 1 1 Features e PIR Motion Detector e 180 Field of View e 12m Detection Range e Built in Twin 60W G9 Halogen Security Spotlights e Sunset Switch Function e Courtesy Li
10. controls how long the COURTESY LIGHT remains illuminated after dusk The Courtesy Light can be Q set to a dim level set by the DIM CONTROL for a period Thar lt 8hrs between 1 and 8 hours Set the SUNSET TIMER CONTROL elo to the desired setting between these limits Wy LUX CONTROL The LUX setting controls the level of darkness required for the unit to start operating The setting is best achieved using the following procedure Set the LUX setting fully anti clockwise gt Y The unit will now start operating at dusk If you require the light to activate earlier wait until the ambient light level reaches the level of darkness at which you wish the lamp to become operative Then SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates Leave the control at this set point DIM CONTROL Vo o e The DIM setting controls the COURTESY LIGHT in SUNSET ae SWITCH MODE The DIMMER is adjustable from 0 OFF to 95 of the light output When set the DIMMER will activate oO Slo the light at dusk each evening It will then stay illuminated at Q this low level of courtesy lighting until the sensor is activated When movement is detected the lamp will go to full power for the time period set by the PIR TIMER control After the set time has elapsed the light level will return to the dimmed light level until the SUNSET TIMER period has elapsed Clipsal Australia Pty Ltd 9 of 20 754
11. curity Twinspot Installation Instructions 4 0 Detection Range Setting Controls TOP VIEW Less Sensitive SIDE VIEW More Sensitive SUNSET TIMER ff 12 of 20 Clipsal Australia Pty Ltd 60W Security Twinspot Installation Instructions 754HB2 180 60 5 0 Installation Diagram 13 of 20 Clipsal Australia Pty Ltd 754HB2 1 80 60 60W Security Twinspot Installation Instructions 6 0 Connection Diagram Wall Plate Cable Entry Earth Neutral Green Yellow Active Live Blue Black Brown Red N Fors o Connect the mains cable to N E and L connections in the terminal block Match the three pins on the unit to the wall plate 14 of 20 Clipsal Australia Pty Ltd 754HB2 180 60 60W Security Twinspot Installation Instructions 7 0 Angle Adjustment The individual spotlights can be adjusted to angle the beam to cover the required area The beam angle can also be adjusted by turning the back of the spotlight clockwise anti clockwise to change the beam pattern CAUTION IF THE PROTECTIVE GLASS SHIELD FOR THE LIGHT IS DAMAGED OR CRACKED IT MUST BE REPLACED IMMEDIATELY 8 0 Lens Masking Diagram The arrows indicate the front of the detection area in that section of the sensor Engraving indicates the approximately detection range of each section Clipsal Australia Pty Ltd 15 of 20 754HB2 180 60 60W Security Twinspot Installation
12. ght Dimmer Feature e Integral Override Facility e Customisable Detection Area Zone Mask Supplied e P44 Weatherproof Rating Clipsal Australia Pty Ltd 3 of 20 754HB2 1 80 60 60W Security Twinspot Installation Instructions 1 2 Wireless Alarm Upgrade Kit Did you know that a Wireless RF Accessory Kit 754RFKIT is available for this unit The upgrade kit is battery powered and retro fittable no extra wiring is required Simply plug in the external RF Transmitter to the floodlight and the portable Chime Receiver will alert you to any external activation of the floodlight 754RFKIT Wireless Alarm Upgrade Kit e Retrofittable Upgrade e 6 Selectable Alert Tones Including Chimes Knocking Sonar and Barking Dog e Incorporated Snooze Function e 100m Wireless Transmission e Battery Operated 3xAA Not Included e Indoor Use Only e Compatible with 754HL1 140 150 754HS1 140 60 754HS2 140 60 754HF1 180 150 754HF1 180 300 754HB1 180 60 754HB2 180 60 4 of 20 Clipsal Australia Pty Ltd 754HB2 180 60 60W Security Twinspot Installation Instructions 2 0 Installation Procedure Unit is for outdoor use only Unit must be mounted on a non flammable surface as a fixed luminaire and is not suitable for portable use The unit can get very hot during use Ensure the unit has cooled before handling Ensure adequate ventilation space is allowed between the unit and any object above in front or to either side of the unit S
13. ins supply 2 Unscrew the glass cover on the lamp housing 3 To remove existing lamp carefully pull lamp from socket 4 Install new lamp making sure not to touch the lamp with bare hands It is suggested that the lamp is handled using a dry cloth Push firmly to ensure that the lamp is properly seated in the lampholder 5 Screw the glass cover back into place on the lamp housing WARNING e Always handle quartz halogen lamps with a soft cloth Do not touch the lamp with your bare hand as it will shorten the life of the lamp e Do not touch the floodlight while it is in use or still hot Switch the unit off and allow it to cool about five minutes before touching it e Inthe event of the cover glass shattering do not replace with normal household glass Do not operate without the glass shield in place If the glass shield is cracked or damaged it must be replaced If the glass is replaced use only tempered glass of equal thickness The Environment and You Clipsal products are designed and manufactured to give many years of trouble free service The materials used during manufacture have been selected to improve their ability to be recycled when the product is no longer functional Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice Light Pollution and Considerate Lighting Please be aware of the a
14. nnoyance over lighting an area can cause to your immediate neighbours Light pollution caused by incorrectly installing a unit or over lighting an area can be limited by carefully considering the location and position of your unit before installation The light spread on all halogen floodlights can be reduced by angling the floodlight downwards on the mounting bracket This will also concentrate the light on your property and limit the potential inconvenience of the light shining into your neighbours windows etc Clipsal Australia Pty Ltd 7 of 20 754HB2 1 80 60 60W Security Twinspot Installation Instructions 3 0 Commissioning Procedure 3 1 Walk Testing Procedure 1 The sensor will rotate from left to right Adjust the sensor to point in the desired direction see Diagram A and H for the different sensor patterns and lens masking 2 Set the two adjustment knobs on the sides of the sensor Diagram C to the following positions PIR TIMER Fully anti clockwise SUNSET TIMER Fully anti clockwise Full Sunlight Fully clockwise om 0 Off Fully anti clockwise 3 The unit will now operate during daytime as well as at night illuminating the lamp for approximately five seconds each time This allows testing to be carried out to establish the best position for the sensor 4 Switch on the mains power The lamp will immediately illuminate as the unit goes through its warm up period After approximately one to two minutes the
15. ser Adjustable Light Level Inhibit Threshold 1 Lux to 2000 Lux User Adjustable Courtesy Dimming Control Range 0 95 User Adjustable Warm up Time 1 2 Minutes Mounting Surface Wall Mount Flat Surface Required Environmental Protection IP44 weatherproof Ne Specifications Typical 240Va c 25 C No User Servicable Parts Inside This Product is Recommended for OUTDOOR USE ONLY Clipsal Australia Pty Ltd 17 of 20 754HB2 1 80 60 60W Security Twinspot Installation Instructions 11 0 Warranty 1 The benefits conferred herein are in addition to and in no way shall be deemed to derogate either expressly or by implication any or all other rights and remedies in respect to the Clipsal Product which the consumer has under the Commonwealth Trade Practices Act or any other similar State or Territory Laws The warrantor is Clipsal Australia Pty Ltd of 33 37 Port Wakefield Road Gepps Cross South Australia 5094 Telephone 08 8161 0511 With registered offices in all Australian States This Clipsal Product is guaranteed against faulty workmanship and materials for a period of two 2 years from the date of installation Warranty excludes any user replaceable parts in particular lamps and glass panels No liability is accepted in relation to discolouration of plastic or painted parts Clipsal Australia Pty Ltd reserves the right at its discretion to either repair free of parts and labour charges replace or offer ref
16. stralia Pty Ltd unless otherwise noted F2108 03 CLIPCOM 21420 May 2010
17. tralia Pty Ltd 5 of 20 754HB2 1 80 60 60W Security Twinspot Installation Instructions 2 2 Mounting the Unit 1 Remove the wall plate from the unit by inserting a terminal screwdriver into the slot at the top see Diagram D Mark the position of the fitting holes Drill the holes Insert wallplugs into the holes BEFORE SECURING THE WALLPLATE TO THE WALL PIERCE AND PASS THE CABLE THROUGH THE GROMMET 4 Attach the wall plate to the wall see Diagram E 2 3 Electrical Connections 1 Connect the cable to the terminal block on the wall plate as follows see Connection Diagram F NEUTRAL Blue Black nl EARTH Green Yellow ACTIVE LIVE Brown Red 2 Ensure that the connections are secure 3 To reattach the unit to the wall plate line up the two pins at the top of the unit 4 Push the unit against the wall plate and the unit will click into place Ensure that the bottom clip is fully closed to ensure a weatherproof seal See Diagram E NOTE It is recommended that a separate switch be installed inside the premises to switch power to the unit ON and OFF This allows the sensor to be easily switched off when not required or for maintenance purposes refer to Manual Override Mode on page 11 6 of 20 Clipsal Australia Pty Ltd 754HB2 180 60 60W Security Twinspot Installation Instructions 2 4 Halogen Lamp Replacement Caution Replacement lamp type is 240V 60W G9 mains halogen lamp 1 Isolate the ma
18. uggested space is 0 5m above 0 3m to either side and 1 0m in front Do not attempt to install during wet weather conditions All electrical installations must be carried out by a Licensed Electrician 2 1 Selecting a Location 1 The motion detector has a number of detection zones at various vertical and horizontal angles as shown see Diagram A 2 A moving human body needs to cross enter one of these zones to activate the sensor The best all round coverage is achieved with the unit mounted at the optimum height of 2 5m 3 Careful positioning of the sensor will be required to ensure optimum performance See Diagram B detailing detection range and direction 4 The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS see Diagram B Therefore position the unit so that the sensor looks ACROSS the likely approach path 5 Avoid positioning the sensor where there are any sources of heat in the detection area extractor fans tumble dryer exhausts etc including any other light sources such as other security lighting 6 Reflective surfaces i e pools of water or white painted walls and overhanging branches may cause false activation under extreme conditions 7 During extreme weather conditions the motion sensor may exhibit unusual behaviour This does not indicate a fault with the sensor Once normal weather conditions return the sensor will resume normal operation Clipsal Aus
19. und in respect to any article found to be faulty due to materials parts or workmanship This warranty is expressly subject to the Clipsal Product being installed wired tested operated and used in accordance with the manufacturers instructions All costs of a claim shall be met by Clipsal Australia Pty Ltd however should the product that is the subject of the claim be found to be in good working order all such costs shall be met by the claimant When making a claim the consumer shall forward the Clipsal Product to the nearest office of Clipsal Australia Pty Ltd with adequate particulars of the defect within 28 days of the fault occurring The product should be returned securely packed complete with details of the date and place of purchase description of load and circumstances of malfunction 12 0 Technical Support For all technical enquiries and assistance please contact our National Customer Service Enquiries Hotline Tel 1300 2025 25 Fax 1300 2025 56 18 of 20 Clipsal Australia Pty Ltd 754HB2 180 60 60W Security Twinspot Installation Instructions 13 0 Notes Clipsal Australia Pty Ltd 19 of 20 754HB2 180 60 60W Security Twinspot Installation Instructions 14 0 Product Range The following products are also available in the 754 Series 150W Security Floodlight 754HL1 140 150 140 Passive Infrared Outdoor Motion Detector Complete with 150W R7s Linear Halogen Floodlight 60W Security Spotlight 754HS1 140 60 1