Home

AN 4B

image

Contents

1. IMPORTANT NOTE it has been observed that once power is cycled to the antennas they will not establish the link until we enter the telnet menu of one of them BU for example even if no option is changed So a PC is necessary to put the link to work APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGANES MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web Wwww aeq eu N I F A 28620649 Refer to the manual to get deeper information http www intelek cz db repository nsf v E1B3DBF8B18B1D48C12576CD00442889 file Manual Alvarion_breezenet_B_ 6 0 system_manual pdf 6 CONFIGURATION OF PHOENIX AUDIOCODEC USING REMOTE CONTROL SOFTWARE All audiocodecs in the Phoenix family except for Phoenix Portable can be remotely controlled through ControlPHOENIX software installed on a PC that is connected to the equipment by IP Once we have access to the equipment the first thing to do is to configure its IP address When we connect the Phoenix to a network we must have a free IP address within the range allowed in that local network This network must be the same in the antenna v Asan example if the Ubiquity antennas have IP addresses 192 168 1 20 default one and 192 168 1 21 after we have changed it we can assign the Phoenix codec and the used PCs IP addresses 192 168 1 22 amp 192 168 1 23 with a net mask 255 255 255 0 for example The IP and mask of the Phoeni
2. AUDIOCODECS AEQ PHOENIX APPLICATION NOTE 4 B Connecting two Phoenix Audiocodecs through a point to point IP radio link operating in the 5 GHz band Configuration of the units via remote control software 1 DESCRIPTION OF THE SCENARIO Recently several manufacturers have started to offer digital radio links with IP connectivity based on IEEE 802 11a using extremely directive antennas that operate in a free RF band These links can be used to transport data between several locations to join venues of a same organization or grant Internet access to places where ADSL is not available The main features of these products are long range low power consumption and nice cost effectiveness We can use them for bidirectional audio transport between two radio broadcast production centers in a same town or setting up a link between radio studio and transmitter STL or between a remote location where some event is being held and the radio studio We have evaluated two solutions with different cost and performance ranges Ubiquity presents a wide range of systems with different performance levels and a very adjusted price that operate under the same setup operation software platform called AirOS v5 that is incorporated in the equipment as an embedded Web server The IP Nanobridge M 5G22 system has been tested but the procedure followed is very similar to tens of Ubiquity products that are configured the same way On the other hand we have also
3. Call to field with the IP of the other Phoenix we want to connect to 10 APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGANES MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web Wwww aeq eu N I F A 28620649 Note that if only the IP address is filled in audio stream will be sent to port 1024 by default In case we need to specify a different port just type it in the same line with the following format lt IP_address gt lt dest_port gt as shown in the following example Call on Channel 1 Call to gt 192 168 1 23 1032 E Channel interface Neti RTP raw IP to Calls a Contacts ESAE 172 26 33 127 1024 Channel 1 2 gt 01 01 2000 00 00 00 72 20 33 127 1024 Channel 1 gt 01 01 2000 00 00 00 00 00 00 172 26 33 127 1024 Channel 1 gt 01 01 2000 00 00 00 00 00 00 172 26 33 127 1028 Channel 1 gt 01 01 2000 00 00 00 00 00 00 172 20 33 26 3004 Channel 1 gt 01 01 2000 00 00 00 00 00 00 172 26 33 127 1028 Channel 1 gt 91 01 2000 00 00 00 00 00 00 172 26 33 26 5004 Channel 1 gt 01 01 2000 00 00 00 00 00 00 172 26 33 26 5004 Channel 1 y The communication will be established by clicking on the green CALL button assuming that we have already done the same in the other end IMPORTANT NOTICE This setup and THE CALL must be repeated in the other Phoenix RTP protocol is connection oriented no
4. selected for our tests a system from Alvarion BreezeNet B14 It is more costly its configuration is less intuitive but it is relatively capable without direct line of sight a characteristic that can make it very useful in some cases where other equipments such as Ubiquity s can t establish a link There are some other European and North American manufacturers each one with its own cost and functionality characteristics But after the tests we reached the conclusion that most of them will be able to work more or less easily with one or several pairs of Phoenix Audiocodecs in order to send one or more bidirectional audio programs In fact the large bandwidth offered by this kind of products allows sending one or more linear uncompressed audio channels through the same radio link max 2 stereo channels when using Phoenix Studio or Venus 2 REQUIRED HARDWARE RS 1 Two AEQ Phoenix family professional audiocodecs Phoenix Studio Mercury Venus or a combination of them even more than one pair RS 2 Two Ubiquity NanoBridge M 5G22 Alvarion BreezeNet B14 or similar antennas 1 APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGAN S MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web www aeq eu N LF A 28620649 RS 3 Connecting cabling 4 Ethernet cables 2 POE adapters POWER POWER SWITCH IP SWITCH IP OPTIONAL OPTIONAL PHOENIX Oma a PHO
5. ENIX ems Phoenix MERCURY Phoenix MERCURY AUDIO LO AUDIO LO RADIO STUDIO REMOTE TRANSMITTER J INO I ALLAIION v Install one antenna at each of the ends of the communication to be established iy E ith UE ik i i NN AN AA aN Wid Wii Mie 4 ii ye rei Front and rear images of the Ubiquity and Alvarion systems APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGAN S MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web www aeq eu N I F A 28620649 The installation of each antenna is usually made with the included mounting hardware v Connect the AEQ Phoenix audiocodec to the NANOBRIDGE M 5G22 antennas in each end The antennas are fed by means of POE adapters which combine data and power supply to the same RJ45 cable that is connected to the radio system Connect the mains cable to the POE adapter that is supplied with each antenna Ubiquity and Alvarion POE adapters Connect the Ethernet cable between AEQ Phoenix use NET1 connector if possible and the POE unit IMPORTANT NOTE use the LAN port for this connection or permanent damage can be produced to the connected equipment RECOMMENDATION install a small Ethernet switch between the audiocodec and the POE unit that will allow you to connect other equipments such as a laptop that will help in the remote configuration of all the equipments connected in this setup This will also allow
6. ICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGANES MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web www aeq eu N I F A 28620649 e First of all it is important that we change the IP addresses of at least one of the units from the default value 192 168 1 20 to a different one i e 192 168 1 21 In order to do that just click on the Network tab NanoBridge M5 All Ui MAIN WIRELESS NETWORK ADVANCED SERVICES SYSTEM he te Network Role Network Mode Bridge Disable Network None hi Network Settings Bridge IP Address pcp Static IP Address 192 168 1 20 Netmask 255 255 255 0 Gateway IP 192 168 1 1 Primary DNS IP Secondary DNS IF MTU 1500 Spanning Tree Protocol E Auto IP Aliasing F IP Aliases Configure VLAN Network Settings Enable VLAN E Firewall Settings The new address 192 168 1 21 must be typed inside the IP Address field Next click on Change button in order to apply the changes Finally we will be presented a window on the top part of the screen in order to confirm the new parameters Just click on Apply From now on once the antenna is restarted we must change the IP address in the browser URL bar in order to continue connected to it e Next it is necessary to establish the operating mode In order to do that click on the Wireless tab and in one of the antenn
7. OOS 2230 1825 43 dBm 52 48 dBm 92 dBm 100 270 0 Mbps 270 0 Mbps AP MAC Signal Strength Chain 0 Chain 1 Moise Floor Transmit OCG THR Rate Enabled 94 83 AirMax AirMax Quality AirMax Capacity Please note that the the better aligned the antennas are the higher value of Signal Strength we will get We can also use the Antenna Alignment utility in the tools menu APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGAN S MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web www aeq eu N I F A 28620649 Gb WET Bullet MS Antenna Algrmant Taa Monilla Firefox fu Tem Fleer nipa lewat SES eee eee ane Kir bores J d Maxs onat m h in Linke The management window shows statistics of the transmitted and received IP traffic Minne J tire ped Slo lee AHF Pee Hebe f Feel Punt Foes UAC Deeg Ling WAH gp Rt ibope SE TE iiba cif i E Tp E ore 5 nth Ranesh In order to monitor the received signal level connecting to both antennas aligning them and monitoring only one is enough as the received level will be equivalent in the other end Nothing else is required to connect both antennas although there are several optional parameters in order to establish security parameters firewalls etc Refer to the manual to get deeper information http dl ubnt com guides nano
8. as we will select the Access Point WDS mode while in the other one we will select Station WDS Remember to always apply the changes with the Change button APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGANES MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web Wwww aeq eu N I F A 28620649 We also need to select the antenna physical type please select 300 22 dBi from the list that is shown besides the text Antenna Nanobriage M9 es ua if Sail See GT eee Wireless Mode Seed B Country Code IEEE 602 11 Mode A T DFS Channel Width Channel Shifting 7 Frequency MHz Frequency List MHz Access Point 40 MHz Disabled Auto Extension Channel WIRELESS NETWORK ADVANCED SERVICES E Hide SSID E Obey Regulatory Rules Access Point Access Point WDS 1 Te W Enable ik al aL F Enabled Antenna 300 22 dBi Max TX Rate Mbps MCS 15 300 F Automatic Wireless Security Security MAG ACL Copyright 2006 2011 Ubiquiti Networks Inc From now on we should start getting received signal in both ends of the communications this can be seen in the main screen We can align the antennas using the information in this page particularly with the Signal Strength information in order to attain the strongest possible signal
9. bridge NanoBridge_M2_M5_QSG padf or use the User guide http dl ubnt com guides airOS airOS_UG pdf APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGANES MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web Wwww aeq eu N I F A 28620649 5 CONFIGURATION OF THE ALVARION ANTENNAS In order to setup the link between two BreezeNet B14 or other similar Alvarion antennas the telnet interface embedded in the units is used We must have a PC connected to it by means of a switch or directly in this case we will substitute the PC by the audiocodec once everything s properly configured e After having connected the cable to the computer check that they are in the same network and that IP connectivity exists use a Ping command for this purpose for example The default IP address of the antenna is 10 0 0 1 although once more it is convenient to change one of then so they can be distinguished once the link is established and they are part of the same local network NOTE this is the default IP address Check that it hasn t been changed in any of the antennas before because different addresses are required to operate the radio link as Stated above e Once we can reach the antenna with a Ping command we must open a telnet terminal to set it up properly open a windows command window and type telnet 10 0 0 1 or the IP corresponding to the particular antenna An
10. mode RTP Raw INTERFACE ESEN a a LIF Setup 4 ON AIR APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGANES MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web Wwww aeq eu N I F A 28620649 Make sure that the Alvarion equipment has port 1024 open This is not required for the Ubiquity units v After all this is done select the audio coding mode We recommend that the buffer mode is set as FIX with a minimum size of around 40ms Torir HEHn INTERFACE MSG IF Setup ON AIR Local meen port sane idae butter mac ai Advanced configuration of RTP mode buffer size and type v Next we need to select the desired coding algorithm E LEAL ERO Sa AN a Coding MPEGS Lz 256Kbs aei AORHSATEREG STEREO Pash a 1 I vail ae v In order to ensure a reliable link that automatically re establishes after electric cuts or link failures it is strongly recommended that you set the advanced channel configuration as follows ControlPHOENIX gp CHI Advanced configuration AEQ 28 E Autoanswer Autoanswer Number URI I Leave blank For any Auto hang up if sync loss after E seconds IM Permanent call v Now we only need to establish the communication In order to do so click on the CALL button at the main remote control screen corresponding to this codec We must fill in the
11. t call oriented Use the same audio coding scheme of course You can establish the connection using SIP DIRECT mode in a similar way by calling the units with the convention name lt user gt lt IP gt This procedure is further detailed in the relevant Phoenix User Manual and has the advantage of avoiding the need to call in both ends Once both Phoenix show synchronization green LED the link is completed 11 APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGANES MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web Wwww aeq eu N I F A 28620649
12. user level will be asked for We will type 3 Administrator Next the password is required The default one is private After that we can start configuring the antenna e Check that the three green LEDs in the unit are ON power supply network and radio link e f not done before it is important that we change the IP of at least one of the ends from the default address 10 0 0 1 to a different one i e 10 0 0 2 In order to do that just enter menu 3 Basic Configuration then menu 1 IP Address and type the new IP address e Although we are setting up a symmetrical point to point link one of the antennas must be configured as Base Unit BU while the other one must be a Remote Bridge RB In order to check that go to menu 2 Unit Control and test what s the available target mode in item D of the menu If it allows you to change to RB mode the unit is presently a BU and vice versa If they are not different go to menu 2 and make the required changes so you end up with 1 BU and 1 RB e From now on we should have signal at both ends Check that the LED bar is illuminated with at least several green LEDs indicating that the link has enough signal to noise ratio You will observe that better S N ratio is got by aligning the antennas properly Just look for max S N Nothing else is required to connect both antennas although there are several optional parameters in order to establish security parameters firewalls etc
13. where it asks for an username amp password By default we must type ubnt in both fields After this step is completed we will enter the main screen that shows a summary of the link status present values for the basic configuration depending on the operating mode network parameters and traffic statistics of all the interfaces Network administration parameters monitoring utilities as well as a useful antenna alignment tool ping traceroute and speed tests are also accessible from the main screen t F Erf 0 S i N p oe 7 f anobridge M9 OMAN SPE cere REA TES EE RE PLP Tepe I HUE UH RE AT CGP STEEL EERE ER RAGE HT He ERE EN ASE Device Name UBNT AP MAC 00 27 22 30 18 23 Network Mode Bridge Signal Strength 43 dBm Wireless Mode Station Chain O7 Chain 1 52 48 dBm SSD ubnt Noise Floor 92 dBm Security none Transmit CE 100 e Version w5 3 THR Rate 270 0 Mbps 270 0 Mbps Uptime 1 day 01 16 45 AirMax Enabled Date 2011 01 15 15 55 59 AirMax Quality 54 Channel Frequency 164 S805 MHz AirMax Capacity a3 Channel Width Auto 40 MHz Lower ACK Distance 27 4 0 1 miles 0 2 km DORA Chains 2x2 Antenna Not specified WLAN MAC 00 27 22 30 15 E LAN MAC O02 222 31 15 8E LAN 100Mbps Full ce ge EE SEEE EEEE EEIE AAE AAEE E ee een Throughput AP Information ARP Table Bridge Table Routes Log LAN WLAN 1 2 1 2 i r E Tx 443kbps 0 8 0 0 4 1 2 Mbps 0 E RX 4 14Mbps Mbps 0 APL
14. x unit is configured under the menu SYSTEM gt SETTINGS gt Ethernet Settings for each physical port In Phoenix Studio only one port is needed ETH1 for instance The IP address and mask is configured using the remote control software in Ethernet menu under equipment configuration ControlPHOENIX PHOENIXY MERCURY a eee 97 L Ethernet config Os Configuraton lt seg 8 Oya tat et ee e C rer S j 3 IP Address 192 168 1 22 mE 17226 3323 SMa Gateway IP 192 168 1 1 DNS Server 80 58 61 254 Ethernet module 1 fe Enable DHCP iW _ i A 2l for changes to apply the equipment needs to reboot Communication will be re established in aprox 15 sec Accessing the IP configuration of a Phoenix Mercury v With Alvarion units if the antennas have the addresses 10 0 0 1 default one and 10 0 0 2 alter we have changed it we can assign the Phoenix and involved PCs IP addresses 10 0 0 3 amp 10 0 0 4 with a net mask 255 255 0 0 for example Again the IP and mask of the Phoenix unit is configured under the menu SYSTEM gt SETTINGS gt Ethernet Settings for each physical port For Phoenix Studio only one port is needed ETH1 for instance The IP address and mask is configured using the remote control software in Ethernet menu under equipment configuration v v Next we must configure the selected audio channel to work in IP
15. you to connect several audiocodecs as needed for multichannel links In the case of Phoenix Studio only one of the Ethernet connectors at the back of the unit needs to be used i e ETH1 Connect an Ethernet cable from the POE adapter to the antenna back Note that this port is labelled POE in the Ubiquity unit and Radio in the Alvarion one Connect the analog or digital audio inputs and outputs in the back of the AEQ Phoenix units RECOMMENDATION start with Ch1 for this test Connect the mains cords to each audiocodec Turn all the units on APLICACIONES ELECTRONICAS QUASAR S A C Margarita Salas 24 28919 LEGANES MADRID SPAIN Tel 34 91 686 13 00 FAX 34 91 686 44 92 E mail aeqsales aeq es Web www aeq eu N I F A 28620649 4 CONFIGURATION OF UBIQUITY NANOBRIDGE M 5G22 ANTENNAS In order to setup a link between two Ubiquity NANOBRIDGE M 5G22 or similar units the Web server embedded in the antenna itself is used We must have a computer connected to the each antenna by means of a switch or a direct connection in this case we will substitute the PC by the audiocodec once the antenna is properly configured After having connected the PC to the Antenna open a Web browser and type http 192 168 1 20 in the URL bar It may be necessary to configure the browser so it doesn t use a proxy for local addresses Once we are able to connect to the Nanobridge we will be presented a small Windows