1. Alarm Relay contacts C NO NC full changeover rated 1A 50V DC 32VAC Battery Condition Test Standard default setting is 20mins 28days BCT BCT may be manually controlled via comms port Standby Mode Turns off DC output of PSU amp allows load to run off battery ENVIRONMENTAL Operating 0 50 C ambient at full load temperature De rate linearly gt 50 C to 0 load 70 C Storage temperature 10 to 85 C ambient Humidity 0 95 relative humidity non condensing Cooling Natural Convection except for 12V model Specifications are subject to change without notice No liability accepted for errors or omissions 10 250 Watt a No Break DC charger for lead acid batteries SRZIO MODEL TABLE 4 Factory default setting unless differently DC Output specified at time of ordering MODELS eae oe aie coon F Recomm maa a ag 2 Higher peak loads may be connected Odeg A imit A Load A A directly to the battery and bypassing the E internal overcurrent trip circuit SR250i 12 p SR250 24 SR250 30 SR250 36 SR250 48 PHYSICAL DETAILS OPTIONS AC Input connector IEC320 input socket included Battery Condition May be enabled or disabled on start up BCT Test relay provided to control an external test load DC Output Connec M6 brass stud or Phoenix combicon Plug in or to provide BCT interlock when 2 units are tions style socket amp mating screw terminal block connected for redundancy Please ask o
2. COM on stud output models AC input TO LOADS BATTERY Temperature sensor to be placed on battery or battery terminal REAR PANEL LAYOUT Temperature sensor to be Temperature sensor to be placed on or near battery _placed on or near battery LOAD BATT COM LOAD BATT o i SS A eeoa paeo PT Te foes offer woo woT iraun masra mon 7 LAN LAN Refer to page 7 for description of control terminals 1 4 CONNECTION amp INITIAL TESTING 1 Check input and output voltages of system ensure that they match the equipment All loads should be isolated 2 Check polarity of all wiring Place temperature sensor probe on the batteries or ideally on the battery terminals Connect the LAN port to the Ethernet network 3 Plug in ac input and turn power on Both LEDs will light up after approx 4 sec BATTERY SYS OK LED will go out after another 10 sec since there is no battery connected DC output voltage should appear at both load and battery outputs ensure screws are tightened down on the connector block 4 Refer to separate instruction sheet for information on SNMP monitoring 5 Turn off input power 5 Connect battery 6 Check that ECB internal electronic circuit breaker closes by shorting together the B and L terminals briefly You will hear a relay operate and both LEDs will light up If this does not happen there is a fault in the wiring or the internal battery protection fuse i
3. Sys ox ONER STANDBY No break de power suppyy 24 Month Warranty e High performance No Break DC UPS system e Choice of Ethernet RS485 RS232 output e Separate outputs for load and battery e Battery detection regular battery presence and battery circuit integrity checks e Deep discharge protection for batteries e Battery condition test BCT automatic or user controlled via comms port e Overload short circuit amp reverse polarity protec tion for battery e Temperature compensated output e No transition switching between PSU amp battery e LED flash codes for precise state indication e Mains amp Battery System alarm relay outputs e LAN supervision output for Ethernet versions SPECIFICATIONS All specifications are typical at nominal input full load and at 20 C unless otherwise stated A O bred AND ALAR Input Voltages standard optional Fusing Protection Isolation Efficiency Inrush current Output Power Output Voltages Voltage adj range Temp Compensation Current Limit Line Regulation Load Regulation Noise Drift Hold up time Thermal Protection Overvoltage protection EMI Safety 180V 264V 45 65Hz 88V 132VAC internal link select 88 135VDC specify at time of order Internal input fuse output battery fuse 1KV DC input output earth gt 85 Soft start circuit 250W continuous 0 50 C 13 8 27 6 34 5 41 4 55 2V 85
4. 105 of Vout Temperature sensor on 1 7m lead with adhe sive pad 4mV C cell 10 Straight line profile lt 0 2 over AC input range lt 0 4 open circuit to 100 load lt 1 of rated output 0 03 C 15 20 ms nom max Vin without battery Automatic current de rating if gt 50 C Self resetting Over voltage protection on output at 130 of nominal output voltage CISPR 22 EN55022 class A IEC950 EN60950 AS NZS3260 Battery Charge Limit See Model Table for default settings may be increased to PSU rated current Reverse Polarity Battery reverse connection will open internal fuse and produce alarm Battery Monitoring Detects for presence of battery on start up then every 60 minutes when charge current lt 200mA Battery Protection Electronic Circuit Breaker ECB operates under the following conditions battery discharged ELVD electronic low voltage disconnect activates when battery voltage drops to 1 67V cell adjustable auto reset overload refer to Allows 150 load from battery without act options ECB ing Operates within 300ms for total load gt 600 short circuit Acts within 2ms backed up by fuse Indication LEDs Green Battery System OK Power OK Red Standby Alarms e Mains Fail Mains or PSU fail standby mode e Battery System OK alarms when battery voltage low on mains fail battery missing battery circuit wiring faulty BCT fail if enabled
5. 6 X rated 7 00ms max for 300ms max 2 5 X rateg peak cur rent allowed 1 5 X l rateg until 25 LVD operates 1 5 2ms 300ms Time 2ms 300ms Time INPUT POWER ON INPUT POWER OFF ECB automatically resets ECB trips amp latches off until input power is restored The ECB which is between the load and battery negatives L B operates to protect the charger on over current and to protect the battery from deep discharge LVD when there is no mains power present When input power is present the ECB resets automatically but when the input power is off the ECB will not reset until power is restored For testing purposes when there is no power present the ECB can reset by briefly shorting the B and L terminals together Specifications are subject to change without notice No liability accepted for errors or omissions 6 OPTIONAL CONTROL TERMINALS Terminals 1 4 on the alarm terminal connector block are used for BCT control and LAN supervision which is described below xxx 250 500 750 RELAY SRxxx i Charger N lt To device being aay monitored eg a PC L B 4 l ROUTER 2 G P LAN ALARMS a TERMINAL LAYOUT OPTIONAL 1 LAN supervision output LAN versions 2 BCT interlock signal 3 Start stop BCT using closed contact signal for 0 5s between 3 amp 4 4 connected to L LAN SUPERVISION The SR250 1 LAN PSU charger has a transistor collector output labelled terminal 1 whi
6. Battery detection test in progress Input power on battery system fault Alarm Normal 4 Internal battery fuse has opened or 2 Battery circuit wiring open circuit battery missing ECB has tripped Input power off battery system is OK battery volts gt Vbatl Input power off and battery has discharged to lt V batl Input power off ELVD has activated and disconnected battery from load BCT is in progress LEDs flash slowly aN power on battery condition unserviceable battery voltage lt Vpres during a PSU in standby input power on battery system OK Nid ely LEGEND on zQ fast flash y gt slow flash off 1 eae y ALARM RELAYS AUX Relay is energized when BCT is in progress MAINS FAIL Relay is de energized on loss of mains input power NOTE approx 30 second delay BAT LOW Relay is de energized when either 1 battery voltage 1 8V cell for 2V cells operates only when no mains power present or 2 battery missing or fault in battery circuit wiring alarm does not show for up to bat tery detection interval time 3 battery fails a battery condition test BCT If the system fails a BCT the BAT LOW alarm latches de energized state until either both the mains power input and the battery are disconnected briefly or the system passes the next BCT Specifications are subject to change without notice No liability accepted for errors or omissions 5 SPECIFICATIONS at 20 degrees C Nominal Voltag
7. ch is controlled via the SNMP software and for example may be used to reboot a modem router The output is switched on low state for approx 5 sec if the selected LAN device eg the monitoring PC fails to respond to ping echo requests for a time longer than the configured timeout default setting is 2 minutes Further relay toggles will take place every twice the timeout 4 minutes until the device responds Once the device under supervision responds a SNMP trap will be sent by the SR250 i to indicate that the device has been successfully rebooted The configuration of this feature is done via the LAN Supervision Configuration web page refer to page 17 of the SNMP user manual Specifications are subject to change without notice No liability accepted for errors or omissions 7 MOUNTING DETAILS FOR SR250 STUD OUTPUT SCREW TERMINAL OUTPUT H 80mm S 80mm 7 60mm 76 5 mm 60mm 76 5mm 150mm 162mm 150mm 162mm1 2 mm mm NOTE NOTE The Standard ac The Standard ac power cord Taki power cord protrudes Peo approx 70mm CN approx 70mm F pp pp P l W Specifications are subject to change without notice No liability accepted for errors or omissions 8 SOME TYPICAL NO BREAK DC CONNECTIONS 1 No Break DC charger with additional PSU 2 No Break DC Connection for high peak loads The second PSU is used primarily to provide extra charging current This is a basic connection which is u
8. devices Some Innovative Energies models have non destructive reverse polarity protection but usually a reverse polarity connection will result in a blown fuse or serious dam age to the device Glossary of terms used in our user manuals PSU power supply unit BCT battery condition test ECB electronic circuit breaker ELVD electronic low voltage discon RPP reverse polarity protection EMI electromagnetic interference nect SNMP Simple Network Management LAN local area network DOD depth of discharge Protocol Specifications are subject to change without notice No liability accepted for errors or omissions 2 fro nirocmeton The No Break DC power supply is designed to provide DC power to lead acid batteries for critical back up applications This user manual refers to the SR250 version with an Ethernet port configured with SNMP network monitoring protocol Note that some of the more general information contained in this manual refers to other models in the No Break DC range Features include Monitoring of the battery status and availability at all times Monitoring of input power status Continuous monitoring of power supply voltage battery voltage on mains failure or during BCT pow er supply and battery currents Battery overcurrent protection and reverse polarity connection using an electronic circuit breaker ECB With input mains power present the ECB acts to limit the battery current but d
9. e Default Value V pres Voltage threshold for battery detection amp battery condition test BCT If voltage drops to this level during BCT then 12 2 24 4 30 5 36 6 48 8 2 03V cell the test is aborted and BATT SYS OK alarm shows V shutd Output voltage of PSU during V batl voltage where BATT low alarm 11 22 276 33 44 4 84V cell activates during mains fail Parameter V disco Battery disconnect level on low voltage during mains fail 1 66V cell Bccl Maximum charge current as of rated PSU rated current 100 de Comms communications mode of PSU F continuous data stream of status M responds only to request made by a controller BatDetect Battery detection interval time active only when no battery charge current is detect ed the unit may not detect a missing battery for up to this time BCT length of battery condition test Ret retest option N after a failed BCT further scheduled BCTs are inhibited Y after a failed BCT further scheduled BCTs will be allowed CC Length of charge cycle in minutes hours days ie time between battery condition tests peal 1 Except for 12V which is set at 50 OPERATION OF ELECTRONIC CIRCUIT BREAKER ECB FOR PROTECTION OF CHARGER amp BATTERY Max allowable Max allowable load amps load amps x rated x rated cO co Short circuit condition Short circuit condition ECB trips within 2ms ECB trips within 2ms 7X rated for
10. ns port amp BCT J C with LOAD amp BATT common Note no battery detection function Power 250W Specifications are subject to change without notice No liability accepted for errors or omissions 11 LY CNergles TERMS OF WARRANTY Innovative Energies Ltd warrants its power supplies for 24 months two years from date of shipment against material and workmanship defects Innovative Energies liability under this warranty is lim ited to the replacement or repair of the defective product as long as the product has not been damaged through misapplication negligence or unauthorized modification or repair Thank you for purchasing from Innovative Energies We trust your power supply will exceed your expectations and perform for years to follow sincerely The Innovative Energies team Innovative Energies Limited Phone 64 9 835 0700 Freephone 0800 654 668 New Zealand z 1800 148 494 Australia Fax 64 9 837 3446 Z S Email info innovative co nz Online www innovative co nz In Person 1 Heremai Street Henderson Auckland New Zealand ISO9001 By Post PO Box 19 501 Auckland 1746 New Zealand Certified Specifications are subject to change without notice No liability accepted for errors or omissions 12
11. oes not latch open If no mains power is present then the ECB will latch open on battery circuit overcurrent Deep discharge protection by disconnecting the load at low battery voltage Monitoring of ambient temperature usually temperature near batteries using external temperature sensor Temperature compensation of battery charge voltage essential for battery health where ambient temperatures fluctuate Alarm contacts to enable interfacing with monitoring equipment such as PLCs SCADA security te lemetry Battery condition test BCT at preset intervals or as determined by the user Adjustable battery charge current limit Monitoring of power supply and network settings SNMP traps available for user data logging gt gt gt No Break SYSTEM BLOCK DIAGRAM l LOAD AC MAINS gt LOAD POWER CONVERSION i LOAD OUTPUT VOLTAGE CURRENT LIMIT amp BATTERY CHARGE Ethernet port CURRENT CONTROL Toggle output T CHARGE BATTERY BATTERY TEMF LED oN BATTERY BATTERY CURRENT SENSE ELECTRONIC CIRCUIT BREAKER BATTERY LED SYSTEM ON OK LED REVERSE POLARITY FUSE MAINS FAIL ALARM POWER SUPPLY OFF FAIL ALARM NORMAL OPERATION ALARN LOAD CURRENT lt PSU MAX CURRENT OFF FAIL ALARM Specifications are subject to change without notice No liability accepted for errors or omissions 3 CONNECTION DIAGRAM SR250 L B terminals are labelled
12. ovative energies ISO9001 Ceritied User Manual SR2507 LAN No Break DC UPS with Ethernet port SNMP firmware va11 250W energies No break de power Supply Z367 2 x R250 fitted in 2U rack Please refer to separate user manual for full SNMP instructions 08 06 15 Specifications are subject to change without notice No liability accepted for errors or omissions 1 hsalagion amp Satay Safety The user is responsible for ensuring that input and output wiring segregation complies with local standards and that in the use of the equipment access is confined to operators and service personnel A low resistance earth connection is essential to ensure safety and additionally satisfactory EMI suppression see below HAZARDOUS VOLTAGES EXIST WITHIN A POWER SUPPLY ENCLOSURE AND ANY REPAIRS MUST BE CARRIED OUT BY A QUALIFIED SERVICEPERSON Electrical Strength Tests Components within the power supply responsible for providing the safety barrier between input and output are construct ed to provide electrical isolation as required by the relevant standard However EMI filtering components could be dam aged as result of excessively long high voltage tests between input output and ground Please contact our technicians for advice regarding electric strength tests Earth Leakage Where fitted EMI suppression circuits cause earth leakage currents which may be to a maximum of 3 5mA Ventilation High operating
13. s ruptured see note below The battery voltage will then appear at the load terminals and the BAT LOW alarm relay energises The POWER OK LED stays on for about 30 seconds T Connect load wiring to L and L terminals 8 Turn on ac power 9 After the batteries are fully charged check that the battery continues to power up the load when the input power is turned off NOTE Reverse polarity protection If the battery is connected in reverse the internal battery protection fuse may be ruptured and the unit should be returned to the manufacturer for repair If the fuse is good the voltage measured as at step 3 above should be exactly the same on both the load and battery outputs Specifications are subject to change without notice No liability accepted for errors or omissions 4 FRONT PANEL LEDS WITH BUILT IN SWITCHES BATTERY SYSTEM OK LED on Battery present and above V batt Pushing this button briefly will initiate a battery condition test provided the BCT jumper is fitted refer to page 7 POWER OK LED on Charger output present LED off no mains input or charger in standby mode STANDBY LED on Charger in standby mode no output from charger Push the STANDBY button briefly to put into standby mode PR e e7 Wa Mere B S Battery Battery System OK pa ary System Bias Condition OK Alarm sil zO Normal Normal System Normal Input power on battery circuit is OK Aw N e noma nomat
14. sed when there is a connected load with a peak current greater than 1 5 times the rated current of the charger Standing loads are connected normally and an optional exter nal low voltage disconnect may be used for the peak load optional DIODES FOR OPTIONAL REDUNDANCY Alarms available Alarms Available Pansa a YES Battery Condition Test Fail 3 2 x No Break DC chargers and 2 x battery banks 4 2 x No Break DC charger and 2 x battery banks for redundancy for redundancy and high peak loads Battery condition test fail The diodes isolate the units from one another in the event of a short All No Break alarms are available and the low voltage disconnect for the circuit appearing at the other output and aid current sharing peak load is optionally implemented with an external relay B L x BAT PEAK INPUT Li NORMAL i LOAD B LVD i a ALARMS ee ARMS opt comms l optional comms port BCT interlock port BCT INTERLOCK B L BAT LVD External LVD optional for peak loads ALARMS optional comms port Alarms Available Alarms available Battery Missing YES Battery missing Battery Low YES YES Battery Condition Test Fail 7 Battery low Battery condition test fail Specifications are subject to change without notice No liability accepted for errors or omissions 9 ovative SZ 250W PSU Charger with communication options aKT weno energies BATTERY
15. temperature is a major cause of power supply failures for example a 10 C rise in the operating tempera ture of a component will halve its expected life Therefore always ensure that there is adequate ventilation for the equipment Batteries in particular suffer shortened lifetimes if subjected to high ambient temperatures Water Dust Every effort must be made in the installation to minimise the risk of ingress of water or dust Water will almost always cause instant failure The effects of dust are slower in causing failure of electronic equipment but all electrical equip ment should be cleaned free of any dust accumulation at regular intervals Electromagnetic Interference EMI Switching power supplies and converters inherently generate electrical noise All wiring should be as short as practica ble and segregated from all equipment wiring which is sensitive to EMI Residual noise can be reduced by looping DC wiring through ferrite cores sleeves These are most effective as close to the power supply as possible and as many turns of the wire taken through the core and in the same direction as the core will accommodate External fuse protection Fuses or circuit breakers must be used in all battery circuits to protect against short circuits External fuses should be used for power supplies chargers even though they are usually internally protected Connection polarity It is critical to check the polarity carefully when connecting DC
16. ur les staff f ist ith system design Alarm Connections Plug in screw terminal block aa a a Communication Port Choice of RS485 RS232 Ethernet Enclosure Powder coated or zinc plated steel anodised fori versions aluminium Weight 1 7k PROTOCONMB x Protocol Converter MODBUS via RS485 with a programming port for PC Power MBLink setup Dimensions 242 x 150 x 61mm excluding mounting feet ASU ries SR250 x blank x OE for Ethernet Port and connections LVD Low voltage disconnect level may be custom 19 Rack Mount 2U sub rack option add SR RM2U ized Please call us for further information Optional V I meter for subrack SR METER Refer to Rack Mounting Option data sheet for further details SR250i AC input nie BATTERY ALARMS mA E a S R2 50 1 1 2 T F S L LA N fa Communications Interface Port ae seamen a LAN Ethernet 230V AC switch L 230V AC no switch blank Input voltage and front 110V AC switch U 110V AC no switch G panel switches 110V DC switch H 110V DC no switch J 230V AC switch 300V MOV M To be used with IE OVP HV AC Output DC Connector type Stud S Plug in screw terminal block X Fan cooled With fan F No fan blank Temperature Compensation Yes T No blank DC output Nominal voltage 12 24 30 36 48 Function C No Break DC PSU charger M C with load output at nominal voltage eg 24V i C with communicatio
Download Pdf Manuals
Related Search
Related Contents
67A00-1 OmniTouch 10p User`s Manual Operating Instruction Sony DSC-W610/B Notes Revista Parcerias Estratégicas Versão integral em PDF eko basic - Frank`s Hospital Workshop Ducane (HVAC) 2HP13/14 User's Manual Oracle Applications System Administrator`s Guide Release 11i Sony Ericsson LT25i User Guide Pyle PT-2800 Amplifier Car Audio Amplifier AーM Copyright © All rights reserved.