Home

Submatix 100 ST SCR Manual de

image

Contents

1. The breathing hoses are first fitted to the unit Differing fittings prevent incorrect assembly Close overpressure valve Inflate the counterlung fully via the mouthpiece until the gas starts to vent via the overpressure valve Close the mouthpiece and check the counterlung for signs of pressure loss i As shown left place a 1 to 2kg lead weight on the centre of the counterlung The weight should not noticeably sink over a period of 60 secs is not necessary to conduct the positive pressure test of the exhale counterlung if the unit has the newer separate counterlungs A negative pressure test is however essential Negative pressure test The counterlungs should be sucked dry With the exterior protective cover of the counterlungs open the inner bag coaxial version is checked for signs of relaxation for at least one minute For the separate bag version both lungs are checked for signs of relaxation for one minute Following the test do not forget to return the overpressure valve to your personal setting 78 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 8 Equipment preparation Check cylinder contents Open the cylinder valves and check the manometers With a suitable analyser both mixtures should be analysed The measuring adapter of the Oxyscan A can be used Reclose the valves if the unit is not in use in order to avoid constant gas loss due to the constant flow operating m
2. IART SUBMATIX 100 ST SCR User Manual Exercise chart Pool 1 2 3 4 Llyes Record of pool dive time Date Location Record of open water dives Date Location IART 2008 IART Flowchart IART SUBMATIX 100 ST SCR User Manual IART Training Structure From User to Instructor Prerequisites Prerequisites gt At least 18 years old lt At least 18 years old lt Valid medical within the last 12 months gt IART OWND Instructor or Nitrox Instructor lt IART OWND or equivalent certification with a recognised organization gt Minimum of 50 logged dives lt Valid medical within the last 12 months lt Instructor liability insurance SCR CCR LEVEL User course Nitrox SCR CCR LEVEL I DIVER user 50 logged hours on the requisite rebreather Instructor exam LEVEL SCR CCR Level II course gt SCR CCR Level Instructor gt Level Il user course gt 10 LEVEL certifications lt 30 logged hours level Il requisite rebreather SCR CCR LEVEL Il DIVER Extended Range Cross over from a recognised technical diving organization E g IANTD TDI Instructor exam LEVEL BSAC or ANDI Level I II or Ill through proof of comparable rebreather instructor status 30 logged hours experience at Level the requisite rebreather SCR CCR II Instr
3. SCR 100 ST Course Manual English Edition 4 i 0 IART DIVES THE FATITURE TODAY IART 2008 SUBMATIA SERIES IART USER MANUAL SCR 100 ST REBREATHER Adapted for IART Neil Matthews Level I 2008 Edition IART 2008 IART SUBMATIX 100 ST SCR User Manual Please note The utmost care has been taken in the preparation of this manual We cannot however accept any responsibility or liability for any errors omissions or alterations nor for any consequences possibly arising through use of or dependence on any information contained in this manual The Author and IART HQ are thankful for any observations from the reader concerning corrections or for any new relevant material Note Do not attempt to learn to dive with the SUBMATIX using only this manual This manual is only to be used in conjunction with an IART approved training course Contact headquarter iart de All rights in particular the rights to copy and distribute as well as the right to translate this manual are retained by the authors No part of this work may in any form whether through photocopying microfilm or any other process be reproduced altered or modified without the express written permission of the publisher IART 2008 A word of warning from the manufacturer For your safety please pay attention to the following directions for use The SUBMATIX SCR 100 ST is a unique stat
4. 94 IART 2008 IART SUBMATIX 100 ST SCR User Manual APPENDIX II Tables Table 8 BEVA OTU s Days Total 1 Table 9 IART 2008 95 APPENDIX II Tables IART SUBMATIX 100 ST SCR User Manual Dosage nozzles and maximum operating depths O2 Colour coding ppO 1 4 bar ppO 1 6 bar 80 8m 10m 60 13m 16 50 18m 22 m 40 25 m 30 m 32 33 m 40 m Table 10 Table 11 Nitrox mix Dosage Flow rate loop mix Max duration of the Max duration of the min constant dosage constant dosage Alt 200 bar 4 It 300 bar Res 30 bar Res 30 bar 0 75 73 Oo 226 min 339 min 66 2 226 min 339 min 80 O gt 1 25 20 Os 226 min 339 min 53 Oo 135 min 204 min 47 Os 135 min 204 min 135 min 204 min 113 min 156 min 3 0 3 0 60 On 1 25 5 0 ome a a 43 O2 50 O 1 25 37 Oo 113 min 156 min 20 Os 113 min 156 min 35 Oo 68 min 102 min 40 Op 1 25 31 Op 68 min 102 min 68 min 102 min 38 Op 45 min 67 min 2 25 15 20 Oz 45 min 67 min Table 12 96 IART 2008 IART SUBMATIX 100 ST SCR User Manual APPENDIX II Tables Nitrox mix on Dosage consumption min min 0 75 3 0 73 Oo 27 No 80 Os 1 25 3 0 66 2 34 No 2 05 3 0 20 Oo 80 No
5. It is important to take particular care with the absorber It should always be stored in a sealed container in dry surroundings and never be used for longer than the recommended time When diving with the Submatix SCR 100 ST it is recommended to use Spherasorb absorbent 48 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 1 Components of the breathing Loop This product allows a maximum dive time in a water temperature of 15 C of 180 minutes The time will however vary depending on actual exertion levels and from variations in water temperature When filling the cartridge it is particularly important o ensure e g by tapping the sides that it is correctly packed as incorrectly filled absorber can result in gas channel formation In such channels the absorber lining is depleted faster and this can ultimately lead to an unfiltered flow of gas The result will be an increasing carbon dioxide content within the loop It is important to remember that once the absorber is exhausted it cannot be regenerated Used absorber can only be disposed of Overstepping the limits in use or ccs PRES re using exhausted material could prove to be a fatal of ete mistake Danger of hypercapnia see Module D13 Filling the absorber canister Add absorber until the canister is about half full Tap the canister lightly a number of times rotating the canister as you do so Then fill the canister until the full mark is reac
6. Completely assembled unit with ADV jacket 46 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 1 Components of the breathing Loop The counterlungs Carbon dioxide rich gas collects in the exhale counterlung before either being routed through the absorber canister or vented from the loop via the over pressure valve The OPV is usually positioned in the exhale counterlung so that only expended carbon dioxide rich exhaled gas is lost from the system With the Submatix SCR 100 rebreather the OPV is located at the back of the diver a design that allows optimum venting in almost every normal body attitude under water Such venting will be necessary during ascent due to the increase in counterlung volume as the ambient pressure falls Filtered gas flows from the absorber canister into the inhale counterlung where it mixes with the fresh oxygen rich gas coming from the constant flow supply before being re inhaled by the diver Generally one or more sensors are positioned in the inhale lung to monitor the breathing gas A special aspect of the design of the original Submatix counterlungs is the co axial construction The exhale counterlung is located within the inhale counterlung which helps to reduce the WOB noticeably making breathing from the unit more comfortable Counterlungs earlier models The counterlungs and the over pressure valve OPV Counterlungs new version Plastic spirals are fitted
7. Half life Factors Interval Time in hrs HL Factor x CNS Interval Time in hrs HL Factor CNS Table 7 Example Repetitive dive Following our dive in example 2 we make a surface interval SI of 2 hrs and then a further dive to 15m depth with a dive time of 45 min Once again we use a Nitrox 40 mix How high is the residual CNS loading Calculate the new CNS loading prior to the next dive and also the total loading following the dive Solutions 2 00 hrs SI result according to table 7 in a HL factor of 0 40 CNSrest 28 x 0 40 11 2 Pin15m 2 5 bar ppO Fg P 0 40 x 2 5 bar 1 bar from Table 6 0 33 CNSnew 45 2 47 min x 0 33 15 51 CNStotal 11 2 15 51 26 71 IART 2008 39 D18 Basic physics review IART SUBMATIX 100 ST SCR User Manual Calculating the equivalent air depth To establish no stop times for any mix a simple calculation can be applied to the use of normal air tables As the no stop time is determined by the level of nitrogen that is absorbed during the dive and a raised level of oxygen in the mix correspondingly reduces the nitrogen content the amount of nitrogen absorbed with a nitrox mix is as though the dive would take place at a shallower depth This depth where air would have the same pNz as the nitrox mix used can be calculated This is referred to as the Equivalent Air Depth EAD With this calculated EAD the no stop times from n
8. 1 Components of the breathing Loop Module E1 Components of the breathing loop The breathing loop of a semi closed rebreather consists of the following components e The mouthpiece and inhale exhale hoses e The counterlungs one exhale and one inhale bag gt Anoverpressure valve set in the counterlungs e The absorber canister e The fresh gas supply The Submatix SCR 100 ST is a mixed gas rebreather with closed breathing loop The diver inhales fresh gas from the inhale lung 7 via the mouthpiece 9 Exhaled gas flows through the exhale hose to the exhale counterlung 8 From here the gas flows to the absorber canister 6 where Spherasorb removes the CO from the used gas The cleaned gas flows back into the inhale counterlung 7 Surplus gas is expelled from the loop via the adjustable overpressure valve The mouthpiece with inhale and exhale hoses The rotating barrel mouthpiece can be closed with the help of the white lever and is directly connected to the breathing hoses Mouthpieces which can be opened or closed with just one hand as with the ST100 mouthpiece are preferable The breathing hoses are made from a flexible convoluted material that is resistant to kinking when turning the head or sticking together should a negative pressure arise vacuum Photo shows exhale hose and flow valve left and inhale hose and valve right The non return valves situated on the left and right hand side of the mou
9. IART SUBMATIX 100 ST SCR User Manual D7 Fresh gas supply and Gas dosage The fresh gas supply must be so calculated that even with an unexpected increase in workload e g caused by unexpected stress factors the loop oxygen content will not sink below 16 Vol This value represents the physiological 32 15 lower limit of tolerable pO needed min to avoid the onset of hypoxic symptoms The choices as to what mix to use and how high the level of fresh gas supply constant flow rate should be are not normally determined by the expected work load factor This would demand extensive knowledge of the diving conditions and of the individual oxygen consumption rate for each respective diver The choices are rather more a compromise between an average high consumption and an average economical consumption rate In this way we achieve on one hand a greater safety factor for the diver and on the other hand the benefits of noticeably more efficient gas usage are only marginally reduced Table 3 As stated above oxygen consumption and workload are directly related and influence not only the oxygen content but also the inert gas content in the loop At high workloads the O concentration in the loop will sink and the nitrogen content simultaneously increases resulting in a shortening on the remaining no stop time or increase in the necessary decompression schedule Lower Oz consumption rates reduce decompression requirements
10. Note gt The work load level will affect the oxygen content in the loop mix gt The oxygen concentration in the loop is a ways less than in the Nitrox cylinder Exception After flushing the counterlung will have the same concentration of oxygen as in the supply gas cylinder gt As aresult equivalent air depths no stop or deco times will be affected Each Nitrox mix requires a specific constant flow dosage to guarantee the minimum necessary O2 content in the loop Each time the gas mix is changed the dosage regulator valve must also be exchanged IART 2008 17 D7 Fresh gas supply and Gas dosage IART SUBMATIX 100 ST SCR User Manual 7 2 Gas dosage With rebreathers the dosage of fresh gas can take place in various ways 1 By using a premixed supply cylinder with a Consumption dependant dosage for closed circuit units b Consumption independent dosage for semi closed units 2 By feeding pure or mixed gases into the unit a Dosage for closed circuit units is dependant on consumption and depth b Dosage for semi closed circuit units independent of consumption and depth 1a Consumption dependant dosage in closed circuit O2 rebreathers Consumption dependant dosage is used in closed circuit oxygen rebreathers As the diver metabolises oxygen the counterlung slowly loses volume This reduction is sensed by a demand valve which then opens as an exactly defined pressure
11. along with the fill pressure and the date of the fill should be entered with a waterproof marker on the appropriate label or sticker attached to the cylinder Do not forget to take into account the fluctuation tolerance when calculating the EAD When the diver collects the cylinder he should perform a second analysis of the cylinder contents and countersign the results 2 2 litres nitrox tanks with valves Nitrox 1st stages low pressure bridge and variable constant flow nozzle blue 74 IART 2008 IART SUBMATIX 100 ST SCR User Manual E6 Technical data Module E 6 Technical Data Model SCR 100 ST Semi closed rebreather Gas supply 2 2 litre steel cylinders optional Aluminium or V4A Breathing gasses must correspond to the guidelines for medical oxygen DIN 3188 EN 132 Operating temp 4 C to 34 C Operating pressures 200 to 20 bar Absorbent fill approx 1 7 Kilograms Counterlungs 9 litre coaxial design Further technical Housing dimensions 670 x 390 x 170 mm without hoses and service Weight ca 14 Kilogram information can Buoyancy approx 2 5 Kilogram positive be found on the Flow nozzles 80 60 50 40 32 accompanying Norm EN CE manufacturer s service CD Optional accessories Oxyscan 100 Pro Weight harness buoyancy rescue collar Flow nozzle for 100 oxygen Trim weights approx 3Kg Flow meter 3 available scales MMA 21 0 5 2 5 l min MMA 23 1 10 I min MMA 24 2 5 25 l
12. Ignoring this advice may place you in danger of injury or lead to fatal consequences Diving with a semi closed rebreather requires an all encompassing training to enable the possible dangers to the diver to be recognised and as far as possible avoided Even if you have substantial experience as an air diver with a rebreather you are once again an absolute beginner It can lead to life threatening situations if you think that your former experience is adequate to deal with a rebreather Develop your diving abilities with the rebreather slowly and carefully increase your depth limits very slowly and don t overestimate yourself Never dive alone Care of equipment Avoid contaminating any high or medium pressure hoses or valves that are to be used in contact with oxygen or Nitrox with oil fat mineral or silicone Grease There is a risk of combustion and explosion IART 2008 3 A Pre requisites course structure IART SUBMATIX 100 ST SCR User Manual A Pre requisites course content and course standards Course pre requisites To participate in this course a minimum certification of IART Advanced Nitrox Diver or equivalent as well as at least 50 logged dives The participant must be at least 18 years of age and must present a valid diving medical certificate Should a Nitrox certification fail then the possibility exists to complete this training as an additional module prior to the rebreather course Please consult
13. Oxygen is metabolised in the body to fuel the tissues and CO is a by product of this process On average 0 8 0 9 litre of CO is produced from 1 litre of oxygen metabolised A typical chemical absorber binds approximately 25 litres of CO per 100 grams and break through is considered to have occurred when the CO in the loop after passing through the filter exceeds 0 5 Should water come into contact with the absorber not only the performance of the filter will be affected In addition with certain types of absorber there is a risk that the water and chemical will mix and form a caustic solution that in the absence of effective water traps may reach the mouthpiece and be inhaled This can cause unpleasant burning of the mouth and airways Should you experience burning caused by a caustic cocktail bail out immediately to open circuit and terminate the dive Thoroughly rinse mouth with plenty of freshwater and spray with Auxiloson Visit a doctor Note Only fill the absorber canister shortly before the dive Avoid using absorber with excessive dust content The dust may bypass the various traps and combine with condensation to produce a caustic cocktail Loop flooding can also lead to a sfpausti cocktail De Self assessment quiz D17 1 Whatis the purpose of the chemical absorber in a rebreather D17 2 Canany brand of absorber be used D17 3 List at least two reasons for absorber failure and the conse
14. 76 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 8 Equipment preparation Module E8 Equipment Preparation At the end of this module you should be able to describe the steps needed to prepare the unit for a dive Checking the Dosage See Checking the Constant Flow page 58 The choice of appropriate nozzle relating the choice of mix to the planned maximum depth given a PO 1 4 bar 1 6 bar can be found in the table below MOD Maximum Operating Depth Table 17 Filling the Absorber Canister Fill the cartridge with absorber to a level of about one half and lightly tap the cartridge wall with the flat of your hand to settle the contents Never bang the cartridge on the floor or a hard surface Fill the cartridge and repeat the tapping After the absorber granulate has settled sufficiently place the cartridge collar onto the surface of the absorber with the edge face up Then continue to fill the cartridge until the full marker is reached Lightly blow off any unwanted chemical dust and then close and seal the canister and perform a pressure test To do this seal the outlet pipe with the palm of a hand and blow forcefully into the inlet pipe No air should escape from around the seal of the canister lid Note e In contact with excessive moisture or water the absorber produces caustic foam Should this come into contact with the skin rinse immediately with copious quantity of fresh wa
15. ST SCR User Manual D7 Fresh gas supply and Gas dosage Advantages of consumption independent dosage o Technically simple safe and reliable in use O Pre set dosage valves for the various standard Nitrox mixes e Filling logistics Elaborate constant flow measurements Complex decompression calculations 2a Consumption dependant dosage in closed circuit rebreathers For depth and consumption dependant dosage both pure and mixed gasses are needed and these are either mechanically or electronically adapted within the unit to the actual diving depth When an individually selected and constantly held oxygen partial pressure is maintained by adding diluent gas in the form of air or helium a constantly changing gas relationship occurs which is optimized to the depth The maximum depth limits are therefore set by the chosen diluent gas to be used With electronically controlled rebreathers the oxygen partial pressure is measured by the use of one or more O sensors that regulate the consumption dependant injection of fresh oxygen into the loop Due to this consumption based technique closed circuit units are among those with the lowest gas consumption On the other hand running costs and maintenance requirements are significantly higher Advantages of consumption dependant dosage Most economical gas consumption Bubble free Greater possible depth range Longer no stop times due to the constant pO principle Disadvantages
16. absorbed In this case we would reach our no stop limit after 30 minutes at 29m IART 2008 37 D18 Basic physics review IART SUBMATIX 100 ST SCR User Manual The above two step calculation can also be expressed in a single equation ppO2 FO2 x Ca To simplify the use of the CNS limits it is possible to express the amount of exposure during a dive in terms of percentage Example 2 We plan a dive to 18 m with a dive time of 60 minutes We use a Nitrox 40 premix How high is our CNS loading Once again we start by calculating the ppO Pg Fg x P ppO 0 40 2 8 1 12 bar With this value we can read off the oxygen loading in the CNS table 6 min below To err on the side of safety we round up if the exact ppO gt value is not given This gives a CNS loading at 1 15 bar 0 44 per minute We now multiply this value with the dive time to establish the total loading An ascent time using an ascent rate of 10m min is also included CNSta 60 min 2 min 62 min X 0 44 min 27 28 rounded 28 CNS and OTU Values CNS and OTU values for the given partial pressure of oxygen per minute ppO exposure limit Per min Per min Maximum in min 1 15 227 0 44 1 24 1 20 210 0 47 1 32 1 25 196 0 51 1 40 ont ppO exposure limit Per min Per min Maximum in min _0 60_ 720 0 14 026 070 570 018 047 1 30 180 0 56 1 48 Table 6 E
17. air dive to 14m To simplify these calculations values from the following table can be used An oxygen consumption rate of 1 0 l min is assumed EAD Table Depth 32 Oo 40 Oo 50 02 60 Oo 80 Oz in m 10 12 14 16 18 20 22 24 26 28 30 35 40 42 Table 14 The normal consumption given an average workload lies by most divers somewhere between 0 6 L min and 1 25 L min For more accurate calculation of the EAD the following FiO values can be used See exercise on page 69 Table 15 the FiO values have been rounded up 68 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 3 Dive planning As shown in Fig 8 page 60 we consider 3 initial parameters gt Planned depth gt Nitrox mix gt Maximum ppO Two of these parameters will also be known If we know the maximum required depth then we can calculate the best mix to reflect our maximum pO of 1 4 bar If the Nitrox mix is already fixed E g there is still enough Nitrox 50 in the cylinder following a prior dive and we wish to maintain a maximum pO of 1 4 bar then aided by Dalton s diamond it is possible to calculate the maximum depth See module D18 page 35 For these either calculated or pre determined Nitrox mixes a manufacturers pre determined dosage nozzle Vs must be fitted This selection together with the total quantity of gas determines the maximum possible dive time
18. and for positive buoyancy the surface an emergensy ascent Beware never dive with an inadequately fi filled pail out 6 ylinder Self assessment quiz 4 What is the MOD for a Nitrox 32 mix ES 2 What is meant by best mix 3 List 3 parameters that must be taken into account when planning Nitrox dives E3 4 What is the formula for MOD ES 5 Calculate for the following dive Gas consumption max flow duration Flow nozzle MOD FiO2 EAD no stop time and CNS loading Given Nitrox 50 5 litre 200 bar cylinder Max ppO 1 4 bar dive time 60 minutes Max depth 18 m Oz consumption 1litre min E3 6 List 4 parameters that must be taken into account when calculating bailout gas reserves E3 7 Calculate the required bailout requirement for an emergency ascent given an RMV of 28 litres a depth of 30 metres and a 20 reserve for buoyancy requirements 72 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 4 Use of dive computers Module E4 Use of Dive Computers As the oxygen content pO in the breathing gas fluctuates with the consumption level of the diver the nitrogen content pN will also fluctuate accordingly This fluctuation in pN cannot be registered by a normal Nitrox dive computer Such computers base their calculations on fixed nitrogen content Accurate decompression data is based however on the actual nitrogen content i e the nitrogen partial pressure and the depth If
19. canister has a capacity of 1 8 kg Spherasorb absorbent The effective duration times are related to the following criteria Water temperature 4 2 0 RMV 40l min Oxygen consumption 1 78 l min Break through level 0 5 vol CO in inhaled gas CO Absorption 1 6 l min Resultant effective duration 135 min Water temperature 4 2 0 RMV 30l min Oxygen consumption 1 83l min Break through level 0 5 vol CO in inhaled gas CO absorption 1 2 l min Resultant effective duration 180 min Carbon Dioxide Absorption of SPHERASORB SOFNOLIME CO absorption CO production Using time of scrubber Water temperature at 1 7 kg filling Sofnolime CD 1 2 I min 140 min 4 C 100 I min 1 6 I min 105 min 4 C Spherasorb 1 2 I min 170 min 4 120 I min 1 6 min 125 min 4 C Sofnolime 1 2 min 198 min 4 C 797 1 6 min 148 min 4 C Table 16 According to the US Navy manual edition 4 20 Januar 1999 an oxygen consumption level of 1 7 l min under water is graded as working hard and a level of 2 5 l min as extreme exertion An average work load causes an oxygen consumption level of between 0 8 1 4 l min If these tested results are given a single value of 1 33 I min the normal consumption level of a diver finning constantly under water can be approximated Note Currently Spherasorb has no manufacturer test results for its use in diving units The values presented here are a result of US Navy tests
20. drop is reached allowing just enough fresh gas to flow into the counterlung to re establish the desired volume Consumption dependant dosage is therefore the most economical dosage method and it also allows truly bubble free diving Units like the Oxylon from Poseidon or the LAR V from Draeger work according to this principle Such units are most commonly used for military activities Advantages of consumption dependant dosage Oo Most economical use of gas supply o Bubble free Disadvantages gt More complex dive procedure due to the need for gas flushing e More restrictive depth range 1b Consumption independent constant flow SCR s In consumption independent semi closed units fixed pre mixed gas flows continuously via dosage nozzles into the breathing loop These so called dosage nozzles are connectors or needle valves that are constructed to allow a constant flow volume appropriate to a particular gas mix If a switch to another mix is necessary then it is also essential to exchange the dosage nozzle to one specific for the new mix The correct flow must then be confirmed using a flow meter From a technical point of view consumption independent dosage is the simplest and also the most reliable solution as only a few working components are needed In financial terms the use and maintenance costs of rebreathers with this dosage method are among the most economical 18 IART 2008 IART SUBMATIX 100
21. example the regular opening of the bypass valve as well as the constant flow of gas into the loop If the typical sounds are not to be heard you should react accordingly Furthermore you should regularly check the OXYSCAN 100 PRO readings IART 2008 81 9 Dive techniques for Submatix IART SUBMATIX 100 ST SCR User Manual Note During longer dives moisture condenses in the breathing hoses and this causes some gurgling noises These noises differ from the gurgling caused by a sudden leak in that they do not appear suddenly but rather increase slowly Such condensation is normal and does not adversely affect the performance of the unit Breathing techniques of the SCR 100 ST Due to the nature of its construction such as the patented co axial counterlungs the breathing resistance of the SCR 100 ST is relatively low Nevertheless it is noticeably different to the breathing comfort of open circuit regulators This means that the diver will need a few dives to get accustomed to the new Feeling The first step is to determine your own individual setting for the over pressure valve In comparison to open circuit the diver first becomes aware of a full mouth This is quickly alleviated by exhaling the excess gas through the nose or around the sides of the mouthpiece Nonetheless pressure will once again begin to increase as gas flows constantly into the loop This can cause a lot of gas to be wasted It is therefore importa
22. is a breeding ground for bacteria Therefore scrupulous cl anliness and hygiene during post dive maintenance is essential to maintain the equipment in good order and protect your own health As the counterlung generally does not dry out well it is best to rinse and disinfect it each time the absorber canister must be refilled In the same way it is recommendable to also periodically disinfect the breathing hoses and mouthpiece 84 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 10 Post dive care It goes without saying that if the unit is swapped from one diver to another all loop parts should be cleaned and disinfected After the dive the complete unit should be rinsed down with fresh water The breathing loop components should be allowed to dry fully and then carefully stored In particular all connections the mouthpiece and the cylinder valves should be checked for cleanliness and ease of movement If necessary they should be lightly greased B For storage o Thoroughly rinse unit with fresh water o Remove breathing hoses Rinse and disinfect hoses and counterlungs EW 80 Rinse again with fresh water and allow to dry 6 Empty absorber canister and clean out residual dust Rinse if necessary o Check all O ring seals are clean and O rings in good condition If necessary lightly smear with approved grease 6 Store the unit and all loop components in a dark cool and dry environment r Note i e Only
23. min Every SCR 100 ST can easily be converted to an SCR 100 XT SCR 100 SMS or emCCR Thus the SCR 100 ST serves as a base for additions and for future technical developments 40 43 8 9 5 6 4 100 XT The XT can be 6 6 dived using two differing 4 i Nitrox premixes With this unit the diver can manually switch from one mix to the other using the MPSS F switching block 3 developed by Submatix 100 SMS The SMS self mixing system is a mechanical self mixing system that can be dived in the range of 0 40m The system utilises a depth dependent constant flow dosage and offers the diver a Nitrox mix of 28 32 at all times Further training is necessary to dive with this system Ask your IART instructor for more information emCCR 100 electronic gas injection to aid the manual control of a chosen setpoint within a closed circuit loop The Submatix emCCR 100 rebreather is designed for recreational dives to a maximum of 40 metres with Nitrox or for technical Trimix dives to 100 metres Further training is necessary to dive with this system Ask your IART instructor for more information IART 2008 75 E 7 Absorption properties of Spherasorb IART SUBMATIX 100 ST SCR User Manual Module E7 Absorption properties of Spherasorb Spherasorb is recommended by Submatix for use with the 100 ST Its specific properties are listed below Duration time of Spherasorb The Submatix absorber
24. nozzle must be fitted to ensure an adequate oxygen supply The nozzles have colour coded rings and an O ring sealed cap After connecting the nozzle tighten the safety nut by hand ADV with connected flow nozzle Constant dosage via the bypass valve The constant fresh gas dosage commonly known as the constant flow is regulated by a needle valve nozzle that is designed to allow an exactly calculated quantity of gas to flow through It is important to know how much oxygen the gas flow contains as this is a major factor in determining the loop oxygen content The standard nozzle supplied with the Submatix SCR 100 ST is designed for a Nitrox 50 gas mix and with this mix the unit will always be able to maintain enough oxygen in the loop to be breathable With this nozzle the fresh gas flow will contain at least 2 5 litres of oxygen per minute and this guarantees a ppO of at least 0 16 bar even with the highest breathing consumption rates The flow rate can be individually set by using a flow meter or another suitable measuring device See page 58 As an option there is also the possibility of installing other nozzles for use with alternative Nitrox mixes These are easy to identify through the colour coding that they carry The table overleaf shows the available nozzles and 2 the equivalent gas mixes 56 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 2 Gas dosage and constant flow Dos
25. of the base plate section of the housing and a further 2 kg to be placed centrally under the counterlungs This neutralizes the positive buoyancy of the unit and offers the diver an optimum swimming position Descent Directly before entering the water both cylinder valves should be opened and before beginning the descent the loop must be flushed to safely avoid a hypoxic situation caused by falling ppO levels at shallow depths from occurring This is accomplished by inhaling from the loop and exhaling through the nose three times Following this flush the mouthpiece should not be removed again to avoid re inhaling ambient gas To begin the descent vent gas from the buoyancy compensator The familiar method of exhaling used for open circuit does not work well as here the gas drawn from the counterlung is immediately replaced due to the constant flow Avoid fast descents as in addition to the constant flow the bypass valve will open in order to maintain loop volume if ambient pressure increases too rapidly This is an inefficient use of gas During the dive depth should be held as constant as possible Saw tooth profiles waste a lot of gas Each time a reduction of depth occurs the gas in the counterlung will expand and some will be vented and lost through the overpressure valve Additionally buoyancy control will be affected and continual compensation will be necessary During the dive you should also concentrate on the typical sounds for
26. onset of hypoxia could be e Tunnel vision e Tingling sensation e Warm feeling e Loss of concentration The intensity of these symptoms will vary from individual to individual and in some cases may not necessarily appear at all If the partial pressure falls below 0 16 bar this will lead eventually to unconsciousness 0 10 bar and further drops lead to brain damage coma and ultimately death For the diver unconsciousness due to the risk of drowning is already extremely dangerous However if this situation is corrected before the onset of unconsciousness the body generally recovers within seconds Note Often there is no recognisable symptom that warns of imminent unconsciousness Therefore it is of great importance as with hyperoxia that every rebreather diver understands the limits and possible causes of hypoxic situations Through careful dive planning preparation and execution the diver must exclude the chance that a hypoxic situation can occur Note l i Commencing a rebreather dive with a filled loop but closed cylinder valves will lead quickly 0 3 hypoxic situation To avoid this Strictly adhere to the _pre dive check list Emergency assistance after recovery from water If breathing the casualty should be administered 100 oxygen without delay If resuscitation is required perform oxygen enriched mouth to mouth via a continuous flow oxygen mask or preferably administer 100 oxygen via a p
27. oxygen partial pressure be allowed to fall below 0 16 bar As an average person depending on the level of activity needs between 0 3 2 5 litres of O per minute and the flow rate must be set to cope with the higher values it means that most of the time too much gas will flow into the loop and this unused gas must be allowed to vent via an over pressure valve OPV into the surrounding environment Examples Draeger FGT Draeger Dolphin Draeger Ray Submatix SCR 100 ST The gas supply to such units should always be switched on and off directly before the start and end of the dive to avoid unnecessary gas wastage caused by the constant flow Fresh gas via a demand valve ADV Fresh gas supplied via a demand valve is usually incorporated in addition to a constant flow valve The ADV is often similar in construction to a regulator second stage and it is usually positioned in the counterlungs or very close to them so that a pressure reduction is quickly registered and compensated for This is often necessary during fast descents or when gas is vented from the loop during mask clearing and following a diluent loop flush To provide a semi closed system with the optimum constant flow rate it is necessary to take into account the following parameters gt O content of the premixed cylinder gt The gas constant flow rate through the dosage regulator valve bar l min gt Maximum O consumption of the diver litres min 16 IART 2008
28. should be flushed prior to descent Due to the reducing partial pressure nitrogen will diffuse from the body tissues into the loop and by flushing this away the maximum gradient can be maintained during equalization This process does not happen quickly however and continues during the dive itself Therefore the premixed nitrox injected into the loop continues to be contaminated by diffusing nitrogen It is therefore advisable to flush the loop again during the dive However when using leaner mixes E g 32 Os combined with a longer stay at maximum depth the chance of N gt toxicity occurring cannot be completely excluded Generally the same rules apply for the SCR diver as for the air diver Including no alcohol no medication When diving with oxygen rebreathers nitrogen narcosis is not a significant factor Self assessment quiz D14 1 Name an advantage that rebreathers have in comparison to open circuit equipment in relation to nitrogen narcosis D14 2 Why can nitrogen narcosis largely be ignored when diving with Oz rebreathers IART 2008 29 D15 Buoyancy control IART SUBMATIX 100 ST SCR User Manual Module D15 Buoyancy Control On completion of this module you should be able to explain why the buoyancy control of a rebreather differs greatly to that of open circuit equipment Correct weighting is particularly important Excessive lead necessitates a high volume in suit or wing at depth and excessive ventin
29. that raise the susceptibility to oxygen toxicity e High exertion level CO retention Raised or lowered body core temperature Pre existing sickness or illness e Under medication Be aware of symptoms such as nausea thumping heart fast and shallow breathing If you notice any of these you should bail out to air and immediately terminate the dive By observing the following safety precautions the chance of oxygen toxicity occurring is extremely remote e Stay within maximum pO depth limits e Keep within the oxygen toxicity clock time limits Reduce exposure time by raised exertion levels or raised CO levels 26 IART 2008 IART SUBMATIX 100 ST SCR User Manual D12 Hyperoxia CNS toxicity Self assessment quiz The Paul Bert effect describes What three factors contribute to hypoxia State the NOAA time limits for exposure to a pO of 1 3 bar Per dive Per day List the seven possible signs and symptoms of oxygen toxicity List four factors that raise the sensitivity to oxygen toxicity How can oxygen toxicity be avoided What is the best emergency procedure by an excessively high 7 27 el a ee D12 D12 D12 D12 D12 D12 D12 IART 2008 D13 Hypercapnia IART SUBMATIX 100 ST SCR User Manual Module D13 Hypercapnia On completion of this module you should be able to explain the causes and symptoms of hypercapnia and list the consequences that arise Hypercapnia
30. with EAD and deco table Rest no decompression time RestNDT gt RestNDT NDL RNT Dive time Repetitive dive group RG gt after the dive CNS Oonew gt of this dive CNS 02 after the dive CNS O2 CNS Osnew CNS Ocrest Signature diver Signature buddy 108
31. 0 75 5 0 53 2 47 No 60 2 1 25 5 0 47 Oo 53 No 2 05 5 0 27 Oo 73 No 0 75 6 0 43 O2 57 No 50 2 1 25 6 0 37 Oo 63 No 2 05 6 0 20 Oo 80 No 0 75 10 35 Oo 65 No 40 Oo 1 25 10 31 Oo 69 No 2 05 10 23 Oo 77 No 0 75 15 38 Oo 62 No 32 Oo 1 25 15 26 Oo 74 No 2 05 15 20 Oo 80 No Table 13 EAD Table Depth 32 On 40 On 50 Os 60 O 80 Os in m 6 10 12 14 16 18 20 22 24 26 28 30 35 40 42 Table 14 IART 2008 97 IART SUBMATIX 100 ST SCR User Manual APPENDIX II Tables Table 15 the FiOsvalues have been rounded up Carbon Dioxide Absorption of SPHERASORB SOFNOLIME CO absorption CO production Using time of scrubber Water temperature at 1 7 kg filling Sofnolime CD 1 2 min 140 min 4 C 100 l min 1 6 l min 105 min 4 C Spherasorb 1 2 min 170 min 4 C 120 I min 1 6 min 125 min 4 C Sofnolime 1 2 min 198 min 4 C 797 1 6 I min 148 min 4 C Table 16 MOD Maximum Operating Depth Table 17 IART 2008 98 APPENDIX III Formulae IART SUBMATIX 100 ST SCR User Manual APPENDIX III Pee 1 10 PO FO2 x Es 1 ES2 1 x10 2 x Depth an 0 79 _ Vs FsO2 VO MO 2 Vs VOz 99 Absolute pressure P Dalton s law gt Best mix gt CNS limit gt MOD max operatin
32. 2008 IART SUBMATIX 100 ST SCR User Manual D3 General principles Mounted on the exhale side of the loop there is an over pressure valve that releases excess CO rich gas into the surrounding environment The over pressure valve plays a particularly significant role as it influences depending on its pressure setting the adequate filling of the counterlung and also the breathing comfort To now replace the used O gt content as well as the lost volume in the loop fresh gas is mixed into the remaining loop gas either via a demand valve or a constant flow supply as mentioned above Units utilising a constant flow supply are however equipped with a bypass valve to enable a fast loop flush With closed circuit units pure oxygen is fed into the loop controlled by oxygen sensors and electronics that interpret the sensor outputs to maintain a preselected oxygen partial pressure throughout the dive The replenished oxygen rich gas now flows into the so called counterlungs ready for the diver to inhale The inert gas content in the loop remains unaffected as it plays no role in the metabolic process See fig 2 General advantages and disadvantages of rebreathers General advantages Economical gas consumption Longer dive times Reduction in decompression time possible Reduced exhaust bubbles Almost silent Less body temperature loss due to warm loop gas Less dehydration due to moist loop gas General disadvantages Gas supply not a
33. Bypassed through leakage around absorber canister gt Bypassed by re breathing CO retained in mouthpiece and hoses damaged or incorrectly assembled one way diaphragms in mouthpiece Note Overexertion or incorrect breathing techniques amplify the risk of hypercapnia Early warning signs to control are gt Inexplicable shortage of breath or increased breathing rate Strong headache Nausea vomiting Loss of orientation irritation loss of concentration Beware c Life threatening due to sudden onset of unconsciousness A tN 4 EN a Self assessment quiz D13 1 Which gas causes hypercapnia 018 2 What are the dangers of hypercapnia D13 3 State 3 possible causes of hypercapnia in a rebreather D13 4 Describe the first aid measures for CO2 poisoning 28 IART 2008 IART SUBMATIX 100 ST SCR User manual D14 Nitrogen narcosis Module D14 Nitrogen Narcosis On completion of this module you should be able to explain whether nitrogen narcosis plays a significant role for the rebreather diver As the rebreather diver generally breathes a gas with a nitrogen content lower than when OC air diving the level of nitrogen narcosis experienced at a given depth will be less than that experienced by the air diver At the start of a dive the nitrogen content in the body is balanced with the ambient atmospheric air in other words 79 saturated To reduce the body as quickly as possible to the new nitrogen lean mix the loop
34. C bail out to off board stage swimming horizontally Return to loop after minute APPENDIX IV Quality Control Checklists Qua No gt 4 5 N 13 14 15 16 Add s chang 17 Remove the unit on the surface without aid from partner 18 100 IART SUBMATIX 100 ST SCR User Manual APPENDIX IV Quality Control Checklists Quality control open water dive 1 Signature Signature Date No Exercise Initials Initials of participant Instructor exercise Pre dive check 3 minute pre breathe Weight buoyancy and trim check Bubble check partner Short swim with buoyancy control exercises Adopt differing body positions Note effect on WOB Close and remove mouthpiece replace clear and open Overhead recovery of mouthpiece Bail out open circuit in board gas Clear flooded mask and optional swim without mask 4 4 5 Trigger the bypass valve OC bail out to off board stage swimming horizontally Return to loop after minute Controlled ascent by venting expanding gas via the overpressure valve and or through mouth nose N Close mouthpiece and cylinder valve Quality control open water dive 2 Signature Signature Date No Exercise Initials Initials of participant Instructor exercise 1 Pre dive check 2 3 minute pre brea
35. Initial response to unconscious buddy CBL and in water EAR Remove unit without help on the surface Total dive time for open water should not be less than 180 minutes IART 2008 89 3 Special hand signals IART SUBMATIX 100 ST SCR User Manual Module F3 Special Hand Signals The hand signals for Is my unit leak free Index finder of the right hand held vertically and bent forward to form a question mark Rest of hand forms a closed fist The unit is leak free The thumb and fingers of the right hand form an open barrel shape This is then closed by placing the flat of the left hand over the top of the barrel Bubbles pearling out from partner s equipment Index and forefinger move in a quick walking motion and the hand moves simultaneously upwards Water in loop Index finger of the right hand moves in a wave motion and then points to source of leak Flush the loop With the index and forefinger held straight and tight together touch the tip of the nose and then move fingers away in an upward sweep 90 IART 2008 APPENDIX Glossary APPENDIX IART SUBMATIX 100 ST SCR User Manual A chemical filter that removes CO from exhaled gas An emergency procedure that terminates the dive the bail out system is the technical configuration that enables the diver to leave the loop This is usually but not always an open circuit regulator The point at which the absorber can no longer c
36. RT SUBMATIX 100 ST SCR User Manual F 1 Equipment preparation Part Ill Practical Training Module F 1 Equipment Preparation Pre Dive Checks Check dive plan maximum depth and dive time Check gas mix cylinder content Fit the correct flow nozzle for the chosen mix Fill the absorber canister Check functions of unit Pressure test mouthpiece barrel constant flow Check bail out system 0 0 0 000 Pre Dive Check List The following checks should be carried out before every dive Analyse gas in the Nitrox cylinder Check that the correct nozzle has been installed for chosen mix Check dive plan MOD and dive time Check the absorber replace if necessary Check the fill pressure of both cylinders and connect to unit Connect all hoses and check seals carefully Check non return valves in the mouthpiece are functioning correctly Positive and negative loop pressure test Open and control cylinder valves turning smoothly and easily Check all inflators are functioning correctly Check the bail out regulator Check constant flow operation Check Oxygauge if fitted 3 minute pre breathe test IART 2008 87 F 2 Practical exercises CW dive IART SUBMATIX 100 ST SCR User Manual Module F2 Practical Training Exercises Attention Maximum depth for CW training 5 metres Maximum depth for OW dive 1 10 metres Minimum and maximum depth for OW dives 2 4 20 and 30 metr
37. T 2008 105 Blank page IART SUBMATIX 100 ST SCR User Manual Guarantee The first owner of the unit must return this completed guarantee form to SUBMATIX within 14 days of purchase All dives made with this equipment must be conducted within the limits of the Submatix Dive Planner and signed by the user and his her dive partner To maintain the validity of the Submatix guarantee the owner is obliged to maintain a correctly filled out dive logbook and submit the unit for an annually inspection to a service centre authorised by Submatix If unauthorized modifications have been made or if the service book shows an incomplete maintenance record Submatix accepts no liability for any damage thus ensued SUBMATIX also accepts no liability for any damage that occurs prior to the receipt of the signed guarantee form SEARO adieu dde ees MRE dalos meer eich aera eee cae ance cau mae cee Names 2 eeceaeseeseealeneeemuenute eke aearemmenecnc POS O haine ne ct dial do ue LL a sees NU die Ne nn a aA EMAD O are re acc te Sas teats Sa cae ele et ate is ei a cae See accept the conditions of use Signature accept that if no other place is written in this manual the legal domicile and the place of fulfilment is Erfurt Germany Signature 106 IART 2008 IART SUBMATIX 100 ST SCR User Manual Submatix Guarantee Liability for function and or damage to the unit The owner or user of the unit is liable for the
38. Therefore it is easier to use the following Table 9 40 IART 2008 IART SUBMATIX 100 ST SCR User Manual D18 Basic physics review Table 8 BEVA OTU s Days 1 Table 9 Statistically an OTU exposure of 1450 units inhibits lung function by 10 in 50 of divers A recompression chamber treatment would expose the diver to around 650 OTU s On the basis that a chamber treatment could be necessary after any dive the necessary OTU s are held in reserve and deducted from the daily limit Thus 1450 650 800 OTU s Because the effects accumulate slowly and recovery is also very slow repetitive days of diving yield a reducing daily tolerance See table 9 Self assessment quiz 018 1 Sketch Dalton s Diamond D18 2 What does PG FG and P stand for D18 3 What is the equation for best mix for a given depth D18 4 What are the equations for MOD and EAD D18 5 List 4 parameters that need to be considered on all nitrox dives IART 2008 41 E 1 Components of the breathing loop IART SUBMATIX 100 ST SCR User Manual Part Il Unit Specific Theory Module E Construction and assembly of the Submatix 100 ST At the end of this module you should understand the principles of how the Submatix 100 ST works and be able to list its construction elements Assembly of the Submatix 100 ST rebreather The Submatix Rebreather is a gas recycling unit designed for recreational divers conceived an
39. With the help of the SCR Formula the FiO2 can be found and aided by the EAD formula the no stop time can then be calculated Ultimately although 4 factors influence our maximum dive time the factor giving the shortest time is always the determining factor CNS exposure limit Dependant pO level No stop time Dependant on min FiO2 EAD Absorber Full canister 3 hours Gas supply Nozzle flow rate Vs Exercises Given Find Nitrox 40 2x4l filled to 200 bar 30 bar Res Gas supply Flow nozzle max ppOz 1 4 bar MOD ppO2 EAD No stop time Exertion level light CNS limit Absorber time new fill Absorber fill quantity 1 8 Maximum dive time Planned depth 20m Solutions gt Gas supply 1360 litres gt This gives a flow duration in an ideal situation of 130 minutes gt Flow nozzle 10 4 l min 1 4bar 4 x 10 25m Ta gt MOD The ppO at the planned depth can be calculated from Dalton s formula gt pOz 0 40 x 1 1 2 bar IART 2008 69 E 3 Dive planning IART SUBMATIX 100 ST SCR User Manual EAD calculation gt Os workload factor using Nitrox 40 See Table 15 b 0 875 gt 002 40 x 0 875 35 02 65 No 0 65 x 20m 10 0 79 10 14m rounded up gt EAD gt No stop time of 90 minutes gt CNS limit for 1 2 bar according to NOAA tables 213 minutes gt Absorber time 2 25 with an elapsed time of 0 00 hours 240 minutes T
40. a normal level of 1 5 min Fio 6 5 0 4 1 5 6 5 1 5 FiO2 0 35 or 35 0 But what would happen if the exertion level rises to 2 5 I min Fio 6 5x0 4 2 5 6 5 2 5 FiO 0 025 or less than 3 O FATAL CONSEQUENCES The normal consumption lies by most divers given an average workload somewhere between 0 6 L min and 1 25 L min However this level can suddenly climb in a fight against a strong current or when the diver starts shivering from cold It is therefore very important to always assume the highest possible exertion level and choose the flow nozzle with regard to the chosen mix accordingly Even if you always avoid Jo Jo profiles and fast ascents the loss of gas via the OVP should not be forgotten when calculating the constant Flow Vs If you choose the correct flow nozzle for your mix this factor has already been taken into account The Submatix SCR 100 ST is constructed to ensure that even if the user has an oxygen consumption of 2 5 litres min there will always be a partial pressure of at least 0 16 bar in the loop Note Accidents arising through inappropriate use of constat flow nozzles or incorrect choice of Nitrox premix is solely the fault of the user and is not likely to be covered by any insurance 66 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 3 Dive planning Calculating the equivalent air depth EAD To determine the no stop time for a particu
41. age nozzles and maximum operating depths 0 Colour coding 02 1 4 bar ppO 1 6 bar 80 8m 10m 60 13m 16m 50 18m 22m 40 25m 30 m 32 33 m 40 m Table 10 The unit may only be used with the recommended Nitrox mixes Failure to observe this guideline puts you at risk of hypoxia or hyperoxia as either too little or too much loop oxygen may result The flow nozzles and the corresponded maximum depths are shown on the tank stickers SURPAT OF N max depth PO 1 4 bar PO 1 6 bar Flow Colour MOD 8 10m green 13m 16m black 18m 22 m red 25 30 m blue 33 40 m yellow The low pressure constant flow hose is marked blue and the low pressure hose of the bypass valve is marked green Interior view ADV bypass connector green constant flow connector blue IART 2008 57 E 2 Gas dosage and constant flow IART SUBMATIX 100 ST SCR User Manual Checking the constant flow rate For this measurement use the supplied dosage testing device or another suitable flow meter correctly calibrated for the gas mix to be measured and plug it into the bypass valve connector A Nitrox cylinder with the appropriate mix for the required dosage and at least 50 bar pressure must be connected to the pressure reducing valve The testing device must stand upright on a flat surface for the duration of the test The flow meter should be attached to the exit port of t
42. also a demand valve that is solely for the purpose of supplying an OC bail out alternative breathing source Depending on the planned depth it may also be necessary to carry a further Bail Out supply The first stages are also equipped with intermediate pressure ports for BCD and drysuit inflators When connecting these it should be remembered that gas will come direct from the Nitrox cylinder and that if mixes richer than 40 oxygen are used this will require that the inflator valves and hoses be kept in oxygen service From the right hand first stage a hose feeds the bypass valve regulator that supplies a constant gas flow to the inhale counterlung The pressure reducing first stages and pressure gauge The pressure gauges The pressure gauges allow the contents of the nitrox cylinders to be monitored As a rebreather diver will not immediately notice when his gas supply is exhausted it is essential to monitor the gauges regularly Every user of an SCR 100 ST should be acutely aware that an absence of a continuous supply of fresh gas could in the worst case lead to hypoxia oxygen starvation 52 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 1 Further components of the rebreather The housing The ergonomically formed lightweight GFK housing of the Submatix SCR provides ideal comfort for the user A buoyancy compensator such as a Jacket or wing can be fixed to the base plate of the housing In accordance with m
43. anufacturer s guidelines the protective cover should be mounted and kept closed during the dive In the housing cover there is a short check list The points listed must be checked prior to every dive Optional accessories Weight Harness See Module E6 page 75 IART 2008 53 E 1 Further components of the rebreather IART SUBMATIX 100 ST SCR User Manual Oxyscan ppO monitor The Oxyscan 100 Pro can be used to measure oxygen partial pressures The monitor is activated by contact with water and immediately displays a ppO gt value SUBMATIX The monitor is only to a certain extent suited to calculate den Loop pO in a rebreather Condensation and LES temperature fluctuations are unavoidable aspects of OXTSCAM 100 PRO rebreather diving and both affect the accuracy of the monitor For these reasons the monitor should only be used with rebreathers such as the Submatix SCR that utilise a known Nitrox premix Oxyscan front view If the display shows a reading other than 0 21 when it is first switched on it must be newly calibrated In order to do this the PG 7 screw on the rear of the housing must first be removed Using a screwdriver the unit can be re calibrated to 0 21 pO Following calibration the housing should be reclosed In doing so ensure that the O rings are correctly greased and that the thread is not damaged as the screw is tightened Note Avoid HF radio and Magnet fileds during calibr
44. ation k Oxyscan rear view To analyse the contents of the Nitrox cylinders the sensor head is connected via an adaptor to the cylinder valve An alternative adaptor enables the Oxyscan to be connected to the BC Inflator hose Technical data Submatix SR22 Sensor Life expectancy More than 500000 Vol h Battery life 3 years Recommended temperature range 5 C 35 C max 0 C 45 C Sensor replacement The sensor can be replaced by the user In order to do this the M32x1 5 screw must first be removed Then remove the Molex 3 Pin plug The sensor can now be unscrewed in an anti clockwise direction Before fitting the replacement sensor the O Ring should be removed Screw the sensor in finger tight in a clockwise direction After the replacement the new sensor will need around an hour or so to wake up before reaching its full output potential Sensor storage Sensors should be stored between temperatures of 5 C to 30 C and never exposed to direct sunlight 54 IART 2008 E 2 Gas dosage and constant flow IART SUBMATIX 100 ST SCR User Manual Module E2 Gas dosage and constant flow measurement At the end of this Module you should be able to identify the correct constant flow nozzle for the Submatix 100 ST and know how to measure the constant flow rate The correct choice of constant flow nozzle As mentioned in module 8 for each of the Submatix s approved Nitrox mixes the appropriate constant flow
45. ation Buddy check 0 Close mouthpiece O O O O 0 During dive Check and if necessary adjust the overpressure valve Descend to approx 6m check buoyancy control and perform bubble check Rolls turns etc to experience fluctuations in WOB in relation to body attitude Switch to bail out and back to loop Flush the loop and perform a slow controlled ascent After ascent close mouthpiece and cylinder valve Exercises Open Water Dive 2 min 20m max 30m Before the dive Plan dive Pre dive check Open and close rotating mouthpiece to check for smoothness of operation Buddy check 0 Close mouthpiece OO O During dive Descent buoyancy control bubble check U W Adjust over pressure relief valve Rolls turns etc to experience fluctuations in WOB in relation to body attitude Several switches from loop to bail out and back Loss and recovery of mouthpiece close mouthpiece prior to loss Flush loop Locate own bail out regulator close mouthpiece take several breathes from bail out system return to loop Initial response to unconscious buddy Safety stop on ascent Exercises Open Water Dive 3 min 20m max 30m Descent bubble check U W adjust over pressure relief valve Initial response to unconscious buddy Bail out swimming bail out ascent with safety stop Exercises Open Water Dive 4 min 20m max 30m Descent bubble check U W adjust over pressure relief valve Bail out swimming
46. cent how can excess gas be vented 9 7 ls it sensible to swim on the surface breathing from the loop IART 2008 83 E 10 Post dive care IART SUBMATIX 100 ST SCR User Manual Module E 10 Post Dive Care Checklist after surfacing 1 Close mouthpiece 2 Remove mouthpiece from mouth 3 Close cylinder valves 4 Check contents gauges A Prior to a further dive After finishing a dive there are several things to be done o Close the mouthpiece o Close the Nitrox cylinder valves to avoid unnecessary loss of pressure due to the constant flow The residual pressure in the system will automatically bleed off 6 Rinse the unit off in fresh water after first ensuring that the mouthpiece is closed o Remove housing lid and visually check the colour indicator of the absorber Replace if exhausted o Check for signs of leaks Water in the counterlungs In the absorber canister o Thoroughly rinse breathing hoses and counterlungs with fresh water disinfect with approved product Easy Clean Spray and rinse again Allow parts to air out 6 Empty absorber canister if spent Rinse it in fresh water remove residual dust with soft brush or cloth and allow to dry o Allow all parts to dry in a shaded place Direct sunlight should be avoided o Check for signs of damage o Check cylinder contents and refill as appropriate o Check bail out system 6 Refill bail out cylinder s o Pressure test r A r A r Nofe The loop
47. d built by Uwe Lessmann himself a diving instructor between the years 2001 and 2004 With incredible determination Uwe worked constantly to further improve his early prototypes with at first the simple aim of producing a better unit for his own use Through resolute development and an open minded approach to new technologies a compact easy to handle rebreather has been developed Early in 2004 the unit passed the standards required to gain CE norm approval and since then it has been generally available to the international recreational diving market Uwe personally invested uncountable hours and test dives in the development constantly searching to improve the functional user friendly and safety aspects of the equipment Ultimately he has been rewarded with success The resultant production model is a constant flow semi closed rebreather ideally suited to the demands of the recreational diver The following diagram shows the primary components of the Submatix SCR 100 ST Fig 5 1 Nitrox tanks 7 Inhale counterlung 2 Nitrox pressure reducing valves 8 Exhale counterlung with over pressure valve 3 Pressure gauges 9 Breathing hose set with turn slide mouthpiece 4 Low pressure bridge 10 Bypass valve 5 Constant flow nozzle 11 Bail out regulator 6 Absorber canister 12 Oxyscan ppO monitor optional In the following module the individual components will be addressed in detail 42 IART 2008 IART SUBMATIX 100 ST SCR User Manual
48. d three times by inhaling through the mouthpiece and exhaling through the nose Note After flushing the loop do not remove the mouthpiece again Refrain from inhaling normal air just prior to descent NE gt a gt Ai 6 P Attention gt gt 2 gt DP Yl Never Mompiis dive with the SAA if the checks listed above reveal leaks In such a case the unit should b be disassembled again and rata hose connections checked AC VAE op haat Lx b M vs 9 IART 2008 79 E 8 Equipment preparation IART SUBMATIX 100 ST SCR User Manual Pre Dive check list The following list should be checked through prior to EVERY dive Shake test rattle free Cylinder pressure checked and contents analysed Absorber canister cleaned correctly filled and sealed Non return valves tested on both sides Negative pressure test on loop any leaks Positive pressure test on loop any leaks Constant flow OK Unit correctly mounted All clips closed correctly Mouthpiece correctly aligned barrel closed Pressure gauge OK Oxyscan OK Bail out OK Loop flushed 2 Constant flow correctly set for the mix 44 Self assessment quiz Which information on the cylinder tag should be re checked prior to diving The constant flow gas nozzle must correspond to what What should be paid attention to when filling the absorber canist
49. dosage Alt 200 bar Res 30 bar 226 min 226 min loop mix 73 O2 Flow rate 3 0 Dosage l min 0 75 Nitrox mix 339 min 204 min 226 min 135 min 135 min 20 Ov 53 O2 47 Ov 3 0 5 0 2 25 0 75 60 O 204 204 156 min 135 min 113 min 113 min 27 O2 43 Oo 37 Oo 5 0 6 0 2 25 0 75 50 O2 156 min 102 min 113 min 68 min 20 Oz 35 O2 6 0 10 2 25 0 75 102 min 102 min 67 min 68 min 45 min 23 O2 38 O 10 15 2 25 0 75 67 min ppO 1 6 bar 10m 16m 22m 30 m 40 m 45 min ppO 1 4 bar 8m 13 m 18m 25 m 33 m 20 O2 Green Red 2 25 Constant flow dosage nozzles and maximum operating depth MOD Colour coding Black Blue Table 12 The following maximum depths apply 02 80 60 50 40 32 Table 0 A decisive factor with semi closed rebreathers is the percentage value of actual inhaled 02 FiO3 There are two reasons for this 1 The FiO may not under any circumstance drop below 16 as otherwise the onset of hypoxia cannot be excluded 2 Below 21 the Nitrox mix will have an equivalent air depth EAD deeper than with air itself resulting in higher narcosis and decompression factors The aim is to find a compromise between too high a constant flow Vs supply flow and one that is too low Loop FiO sho
50. e IART 2008 35 D18 Basic physics review IART SUBMATIX 100 ST SCR User Manual 1 Calculating the best mix To establish the best mix we must once again decide on the maximum acceptable 2 level Then we need the planned maximum depth Example A diver plans to dive to 20m and decides that a max ppO of 1 3 bar is acceptable What of oxygen can be mixed We start with the equation FO2 232 P Once again P is replaced by the dive depth The equation now appears as follows FO gt ppOz x 10 D 10 20 m 10 Here one would use a 40 nozzle 2 3 bar 1 0 43 43 O2 2 Calculating the oxygen depth limit A decision has to be made as to what is an acceptable maximum ppO during the dive For a given mix the MOD will vary depending on this decision For OC diving a max ppO of 1 4 bar is universally accepted as safe A number of technical diving organisations allow 1 6 bar as the absolute limit For a rebreather diver whose overall ppO2 exposure is always high in comparison to the OC diver a maximum ppO of 1 3 bar should be considered Furthermore the nature of the dive in terms of stress such as cold and limited visibility exertion level and the fitness of the diver on the day will influence his susceptibility to CNS poisoning We start with the equation _ pO2 FO 2 To deduce the MOD we replace the absolute pressure P with the dive depth The equation now appears as mop PPO _4
51. e level of activity this one off use of the gas demands a considerable gas supply However as the human body only uses the oxygen content within the gas between 0 3 and 2 5 l min depending on work load the majority of the carried gas is wasted As depth increases we move even further from the optimum usage of the carried gas as the 22 consumption remains unaffected by the increase in ambient pressure See module D7 page 16 To improve the scope of self contained equipment and make the use of the carried gas more economical we have the option to use either semi closed or closed circuit rebreathers The method used for supplying fresh gas further subdivides these units into mechanical or electronic categories In all cases the aim is to optimise the gas mix to enable longer no stop times in the respective depths Due to the reduced gas consumption the amount of gas carried can be reduced so that rebreathers can generally be built in a compact and relatively lightweight form Overview of Self Contained Underwater Breathing Apparatus Semi closed rebreathers en Se S Fixed Nitrox Self mixing mixes mech electr gt a aT a O2 Heliox y 0z Trimix Fig 1 IART 2008 7 D3 General principles IART SUBMATIX 100 ST SCR User Manual Module D3 General Principles of How Rebreathers Function At the end of this module you should be able to explain the particularities and principle functions of rebrea
52. e initial parameters are shown by the water droplet shaded fields From these two will be known and a third can be calculated The dark grey shaded parameters all influence the maximum dive time 1 Planned depth Influences choice of the Nitrox mix and CNS toxicity 2 Nitrox mix planned best mix determines constant flow MOD and also the CNS toxicity 3 Max pO determines absolute maximum depth MOD and CNS toxicity Gas supply Determines the maximum possible dive time for the unit Flow nozzle Correct dosage ensures the optimum oxygen supply This is suited to the chosen Nitrox mix Absorber The elapsed time of the absorber influences the maximum dive time EAD determined by work load factor or FiO calculation CNS Dive time and or residual loading from previous dives The maximum dive time is governed by one or more of the following factors Gas supply calculated from cylinder size its total fill minus 30 bar safety reserve and the chosen dosage nozzle No stop time according to EAD CNS and Absorber elapsed time 60 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 3 Dive planning To commence the dive plan the diver must be clear about the maximum depth that he wants to reach during the dive Based on this decision the best Nitrox mix can be filled Subsequently the correct dosage nozzle for the prepared mix can be fitted From the tables the correct constant flow rate can then be determined and in tur
53. e of the art semi closed circuit Nitrox rebreather It is designed and built for recreational diving only with nitrox to a maximum depth of 40 metres Using the Submatix SCR 100 ST the diver is only permitted to start the dive at the water surface The unit must be back mounted It uses two separate cylinders filled with pre mixed Nitrox The gas volume of these cylinders is not conceived for emergency situations While its proper use can provide for an enhanced recreational scuba experience you must understand that as with all rebreathers the SCR 100 ST has certain characteristics which can lead to serious injury or death It must be used correctly It is important to avoid breathing from the unit when the mix gas tanks are closed or empty Before every dive all items on the pre dive checklist must be completed and be ok It is critically important not to attempt to use an SCR 100 ST without first having been trained and certified in its use You must receive training from a nationally recognized certification organization such as IART This IART manual is designed to be a guideline to the proper use of your SCR 100 ST It is not a substitute for thorough appropriate practical training and certification in the use of this rebreather Under no circumstances should the SCR 100 ST be used by anyone who has not been trained and certified to use it It is extremely important that you read and understand every aspect of this manual Should you n
54. echanism Check Octopus By breathing from the octopus you can check whether it delivers gas on demand and by briefly depressing the purge whether it is likely to free flow Note The octopus is not a complete bail out safeguard It is rather just an additional safety factor Reserve bail out gas The use of a bail out system is essential Various options are possible We recommend the use of a side mounted 4 litre cylinder with first and second stages This can also be used for inflating the drysuit or buoyancy compensator See Module E3 page 60 Check Bypass valve Open cylinder valve inhale gas through the open mouthpiece and release it through the nose until the counterlung is fully empty Inhale further gas must flow immediately through the bypass valve in sufficient quantity to balance the demand The adjustment of the bypass valve should only be carried out by a service technician Check Buoyancy Compensator Prior to each use the BC should be carefully checked to ensure it is functioning properly All vents should be operating without hindrance To perform a pressure test inflate the jacket and let it stand for some time If a leak is found this must be repaired before any further dives are carried out Also check the function of the Inflator and over pressure valve Finally vent the BC fully Loop flush Cylinder valves should only be opened just before commencing the dive Following this the loop should be flushe
55. er How are the convoluted hoses tested prior to assembly Describe the negative pressure test Describe the positive pressure test Describe how a loop flush is performed SG Si 5 IART 8 E8 E8 E8 E8 8 E8 E8 80 IART SUBMATIX 100 ST SCR User Manual E 9 Dive techniques for Submatix Module E9 Dive Techniques for the Submatix At the end of this module you should be able to describe the best dive techniques for the Submatix 100 ST Note On descent between 2 3 metres let your diving partner check whether there are any visible leaks from your unit ascending bubbles and listen yourself for any gurgling noises Pay attention to the normal function sounds non return valves constant flow and over pressure valve Observe the special hand signals Practical tips The tips given in this module are the result of experience gained over many dives with the SCR 100 ST rebreather conducted in diverse conditions Nonetheless neither Submatix nor the training organization will accept responsibility for any accidents arising through their use The ideal breathing comfort is obtained by using the SUBMATIX weight harness in combination with the SUBMATIX BC collar Jackets or wings lift the unit away from the diver and this increases the WOB Weighting SUBMATIX recommends placing 2x2 or 2x3 kg weights in the upper left hand and right and side
56. er to optimise the use of the specifically chosen chemical It is important to use only the recommended absorber as both form and size of the granules influence the contact time and surface area of the chemical with the loop gas These factors determine the effectiveness of the filter and the WOB See Module E6 page 75 The absorber converts the exhaled CO in a series of exothermic heat producing chemical reactions into harmless chalk and water CO Absorption can be demonstrated in three simplified steps 1 1 Phase Acid production gas phase carbon dioxide forms carbonate CO H2O e HCO 2 Phase Neutralisation liquid phase carbonate reacts with the hydroxide alkali to produce sodium carbonate und water HCO 2 NaOH NaCO 2 H2O 3 Phase Conversion solid phase Sodium carbonate reacts with the calcium hydroxide to form calcium carbonate By product sodium hydroxide Ca OH Na CO CaCO 2 NaOH The effectiveness of this process is influenced by temperature transition 1 Gas phase 2 Li uid hase time of gas through filter density of the CO2 rich gas Water film packed filter ambient pressure and the moisture content of the chemical The warmer the chemical the better the CO is absorbed Therefore a pre breathe sequence prior to diving is highly recommended to both warm the canister and check that the filter is working In cold water it must be expected that the 3 Solid phase filter will
57. es Minimum total in water time 240 minutes Exercises Confined Water max 5m Routine exercises Remove and replace unit on the surface open and close rotating mouthpiece buoyancy control flushing and experiment with various swimming positions 30 60 minutes dive and exercise time Before the dive Plan dive Pre dive check Open and close rotating mouthpiece to check for smoothness of operation Buddy check Close mouthpiece oo O0 Prior to descent o Open cylinder valve o Check and if necessary adjust the overpressure valve During dive o Check buoyancy o Slow descent perform bubble check with partner o Short swim with buoyancy control exercises o Adopt differing body positions Note effect on WOB o Several switches to bail out supply and back o Trigger the bypass valve o Slow controlled ascent o Close mouthpiece 6 Close cylinder valve o Rescue exercises initial response CBL and in water EAR Note If OW training is to be conducted with the 100 XT version of the Submatix using two differing Nitrox mixes your instructor will give you time to become accustomed to the gas switching block and will expect you to plan and perform a gas switch during OW dives 2 3 88 IART 2008 IART SUBMATIX 100 ST SCR User Manual F 2 Practical exercises OW Exercises Open Water Dive 1 max 10m Before the dive Plan dive Pre dive check Open and close rotating mouthpiece to check for smoothness of oper
58. function of the unit and or damage to the unit if the equipment is not correctly maintained or repaired by authorized personnel trained by Submatix Submatix is not liable for damage caused by incorrect use of the equipment or for components supplied by other dive equipment producers Where notes concerning laws decrees and standards are given they are based on the legal regulations of Germany Guarantee and liability conditions related to sales and delivery cannot be extended through the above mentioned comments The Submatix SCR 100 ST is a mixed gas rebreather for sport divers and it was not designed for commercial application It was designed for fixed nitrox mixtures and the corresponding constant flow nozzle The constant flow rates were chosen to guarantee an oxygen mixture of 20 in the breathing loop at an oxygen consumption rate of 2 25 l min We recommend regularly checking the ppO with a suitable ppO monitoring system during the dive The unit may only be used after successfully completing a training course with an agency recognized and approved by Submatix IART is such a training agency The unit is only certified for use in EU states The use in other countries states especially United States of America and Canada is specifically prohibited have read the manual and completely understand the content accept the liability for regarding function and damage Signature Date Note This page must be signed and sen
59. g gas flow calculations e Need for careful adjustment to dosage regulator valves needle valves e Greater maintenance due to larger number of system components Self assessment quiz D7 1 List the three parameters that must be taken into account when setting the constant flow dosage level D7 2 Whatis the minimum tolerable loop O2 level D7 3 Which factor changes due to high exertion and what are the resulting effects D7 4 Explain why rebreather diving with just air is not possible D7 5 List two methods of gas dosage D7 6 Which types of gas are used in aconsumption dependant CCR D7 7 What essentials must be observed following a switch to a different gas mix D7 8 How can the correct constant flow gas volume be checked 20 IART 2008 IART SUBMATIX 100 ST SCR User Manual D 8 Respiratory physiology Module D8 Respiratory Physiology At the end of this module you should be able to explain the principles of respiration The most important component of any breathing gas is the life supporting oxygen Through combustion the burning of oxygen provides the energy source by which all body functions are maintained The need for oxygen varies from moment to moment dependant on physical activity levels and also varies from organ to organ The organs also react differently to a lack of oxygen The most sensitive being the brain and spinal cord Tissues receiving a lower blood supply such as fat and bone cells are more resistan
60. g and inflation to compensate for depth changes Higher gas consumption a head up swim position and greater drag are the results of overweighting The SCR diver is correctly weighted when with empty suit wing and an optimum volume of gas in the loop he just begins to sink When 3 kg of lead is now added to compensate for nearly empty cylinders and to allow for sufficient suit inflation to provide insulation at shallow depths the weighting should be perfect A typical feature of rebreathers is the inability for the diver to exercise fine buoyancy control by inhaling or exhaling This technique universally used by all OC divers does not function for the rebreather diver as the gas inhaled to increase lung volume is drawn from the counterlung which in turn loses volume correspondingly The same applies to exhalation The gas exhaled returns to the counterlung thus compensating for the reduction in lung volume Exactly this lack of fine buoyancy control that experienced open circuit divers perform subconsciously make the first buoyancy control exercises with an SCR a test of patience and often leaves the diver feeling like an old dog trying to learn new tricks Just as it was in your novice training buoyancy control is once again hand work and must be relearned Under no circumstances should you be tempted to control buoyancy by reducing counterlung volume by exhaling through the nose for example as this will only cause in addition to un
61. g depth EAD equivalent air depth SCR formula IART 2008 IART SUBMATIX 100 ST SCR User Manual Date Of exercise control Signature Initials Instructor tage cylinder and allow student enough time UW to get the feel of buoyancy IART 2008 Signature Initials participant APPENDIX IV Quality control checklist training exercises lity control Pool confined water Exercise Pre dive check 3 minute pre breathe Weight buoyancy and trim check Bubble check partner Short swim with buoyancy control exercises Adopt differing body positions Note effect on WOB Close and remove mouthpiece replace clear and open Overhead recovery of mouthpiece Bail out open circuit in board gas Clear flooded mask and optional swim without mask Trigger the bypass valve Rescue technique Simulation unconscious diver Flush the diver s loop with diluent whilst simultaneously venting excess gas via the overpressure valve and securing mouthpiece Controlled ascent by venting expanding gas via the overpressure valve and or through mouth nose Controlled buoyant lift of unconscious buddy Ensure casualty is positively buoyant at the surface Perform simulated in water expired air resuscitation EAR One breath every five seconds Instructor should allow student to try various EAR and towing techniques Close mouthpiece and cylinder valve es before performing next exercise O
62. h gas consumption in constant flow SCRs is theoretically unaffected by the depth it is nonetheless necessary to use higher dosages for greater depth ranges in order to supply the diver with sufficient oxygen at all times during the dive Gas consumption is therefore primarily a function of flow rate volume and not the actual respiratory minute volume of the diver Greater depths require due to the lower O content in the appropriate selected Nitrox mix a higher constant flow dosage which in turn results in a higher gas consumption rate The inadvisable but by open circuit divers often favoured skip 14 IART 2008 IART SUBMATIX 100 ST SCR User Manual D6 Gas consumption and efficiency breathing technique has no influence on gas efficiency with SCRs due to this constant flow of gas It only adversely affects breathing comfort Approximate values for oxygen consumption levels At rest ca 0 5 l min Normal activity ca 1 0 min Average workload ca 1 25 l min Strenuous workload ca 2 0 min Extreme activity ca 2 5 min trained athlete VVVVV Comparison of the potential dive times of each system 3 0 bar L min 5 0 bar L min 6 0 bar L min 10 0 bar L min 15 0 bar L min Nitrox 80 O2 Nitrox 60 O2 Nitrox 50 O2 Nitrox 40 2 Nitrox 32 Oz Table 2 The actual dive time will be reduced through gas loss caused by mask clearing loop flushing fast descents and saw tooth profiles Self assessmen
63. he constant flow nozzle and the flow can be measured providing the cylinder valve is open The results must be in accordance with the following table i 2 an Las Tolerances for the constant flow setting me E ee Sa 80 green 3 3 15 60 black 6 4 50 red so 5 40 blue Table 11 Flow meters are available in 3 measurement ranges MMA21 0 2 5 l min MMA 23 0 10 I min MMA 24 2 5 25 I min The gas flow through the meter will now have a particular constant flow volume directly related to the installed dosage nozzle and this moves the floating ball in the meter upwards according to how strong the flow is From the position of the ball the gas flow can now be read from the scale on the flow meter To ensure measurement is as accurate as possible the cylinder valve should only be opened very slowly to avoid setting the measuring ball in violent motion A further method to check the gas flow is by timing the flow rate Attach the measuring bag to the bypass valve and ensure it stands on an even surface Via the over pressure valve housing breathe the measuring bag empty and then observe it for approx 20 secs No leaks should occur the measuring bag must remain deflated Then fill the over pressure valve housing with water up to the full mark 58 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 2 Gas dosage and constant flow Throughout the test hold the measuring bag upright in t
64. he hand Now open the Nitrox cylinder and simultaneously start to monitor the time Measure the time it takes before the first bubbles appear in the water filled over pressure valve The measured time must lie within the limits given in Table 12 page 62 Before the unit is used it is essential to analyse the gas mixture to enable possible deviations to be reflected in your dive planning calculations i e EAD If a fast descent raised breathing volume or loss of loop volume e g through mask clearing creates the need for a fast replenishment of breathing gas the ADV will automatically open The loss of pressure in the loop triggers this mechanism in the same way that under pressure in a regulator second stage occurring each time an OC diver inhales causes the membrane to press in against a lever that then deflects inwards and in so doing so opens the valve that lets gas rush in The constant flow is supplemented and in this way sufficient gas in the loop can always be guaranteed d 0 J 0 Note 2 0 22 Pay 2 Ai As the mixture in the breathing loop depen on the work of the diver variations are possible The correct calculation of the decompression ris only possible with a dive computer with oxygen sensors 0 cs If you intend to use such a dive computer ensure that it is compatible with high frequency signals and able to calculate mixes lower than 21 The optionally available Submatix Oxyscan A can be
65. he maximum dive time is determined by the no stop time at the EAD gt 14m 89 minutes Example Calculating dive times The following 4 factors influence the potential dive time Gas supply Gasvorrat and selected flow nozzle Absorbent Minimum of 2 hours for a new filling No stop time dependant on FiN EAD CNS exposure limit dependant on ppO Example We plan a dive in the Red Sea with Nitrox 50 This gives us an MOD of 18 metres for a max ppO of 1 4 bar and 22 metres if a ppO of 1 6 bar is acceptable Our planned maximum depth is 20 metres and accordingly this means that we will be exposed to a ppO of 1 5 bar at that depth Using this mix and assuming that the oxygen consumption level is 1 0 l min the nitrogen concentration in the loop will be around 60 Our EAD is therefore 12 78m which we round up to 13 metres Using Deco 2000 tables we therefore have a maximum no stop time of 72 min According to the NOAA table the CNS limit for the dive lies at 120 min The available gas supply of 680 litres 30 bar reserve calculated per cylinder would last for 104 minutes with a constant flow setting of 6 5 l min In this case the maximum possible dive time is determined by the no stop limit as we have decided that we do not want to undertake any decompression obligations Therefore our maximum dive time will be 72 minutes Submatix dive planner As an alternative aide to better dive planning you can also use the Sub
66. hed Close the canister and install checking that the O rings are clean and correctly seated Furthermore the following guidelines should be observed Fill the canister before every dive An already filled canister can be stored for up to two days providing that it is sealed Ensure that the filter is clean and porous enough to allow gas to flow freely through it Never fill the canister with absorber dust Protect a filled canister from excessive temperature Always follow the manufacturer s recommendations See Module E7 page 76 IART 2008 49 1 Components of the breathing loop IART SUBMATIX 100 ST SCR User Manual The breathing loop shown with the earlier version of the counterlungs While the installation of the breathing bag you have to note that the overpressure valve snaps in correctly in the existing holding device In case of a canted overpressure valve it is possible that water gets into the breathing loop The inhale and exhale tubes must be fixed from the outside with 1 72 screws Caustic burns caused by absorbent Chemical burns can occur if water is allowed to penetrate the absorber canister and no remedial action is taken Water reacts with the soda lime and forms a caustic foam that if it finds its way to the mouthpiece of the diver can cause unpleasant burns The construction of the loop in the Submatix SCR makes such an occurrence very unlikely but poor preparation such as incorrect a
67. his direction with the completion of a recognised Nitrox Diver course The knowledge you acquired from that course will prove invaluable to gaining a thorough understanding of rebreather technology and how to safely employ it The additional theoretical knowledge will be gained through both instructor presentations and also by home study of this manual Self test questions will allow you to assess your own progress This manual will present you in a clear and simple form the knowledge that you will need to become an enthusiastic Submatix rebreather diver As each rebreather has its own specific features we would like to point out that the contents of the manual relate exclusively to the use of the Submatix rebreather even if much of the information is general to all rebreathers The theory is however just one side of the coin Practical application is equally important and you will have the opportunity to gain this under the guidance of a qualified Submatix authorized IART instructor We wish you lots of exciting dives Yours Uwe Lessmann and Torsten Kraushaar IART 2008 1 Blank page IART SUBMATIX 100 ST SCR User Manual 2 IART 2008 IART SUBMATIX 100 ST SCR User Manual Warning and Safety information Warning and safety information Important Diving has inherent dangers Do not attempt to dive with a semi closed rebreather without proper instruction from a diving Instructor specifically qualified for this unit
68. ht combined with long dive duration o Simplicity of design o The absence of exhaust bubbles Disadvantages e Gas not always readily available to the recreational diver e Reduced depth range e High risk potential if guidelines are not correctly followed Note Oxygen rebreathers should only be used in depths of 4 6 metres determined by whether a maximum pO of 1 4 or 1 6 bar is acceptable Self assessment quiz D4 1 Why is a closed circuit oxygen rebreather bubble free D4 2 What can cause oxygen starvation D4 3 Why can hypoxia occur even if the gas supply is 100 oxygen D4 4 What are the depth limits for an oxygen rebreather IART 2008 11 D5 How SCR s function IART SUBMATIX 100 ST SCR User Manual Module D5 How Semi closed Circuit Rebreathers Function On completion of this module you should be able to explain how 8 semi closed rebreather SCR functions In contrast to closed circuit O rebreathers that are supplied only with pure oxygen semi closed units utilise various fixed Nitrox mixes The chosen nitrox mix determines the MOD and careful dive planning is therefore required Fluctuations in the oxygen level in the loop are compensated for by a continuous injection of fresh gas calculated to maintain the pO at a safe level The injection of fresh gas is via a constant flow dosage controlled by a needle valve set either in accordance with manufacturers specifications or user adjusted to maintain the
69. inhalation of expired gas prior to filtration of the CO content is made impossible However these membranes should be regularly inspected to ensure their serviceability A small tear improper seating dirt under the seal or simply deterioration with age could all result in the non return valve failing with the associated risk of hypercapnia 44 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 1 Components of the breathing Loop Before mounting the plug in connectors you have to ensure that the corresponding O rings are in good condition and correctly seated When assembling the locking mechanism must snap in The connection can be checked by tugging lightly Note The connections are colour coded RED used gas GREEN fresh gas To avoid incorrect assembly ensure that the colours match The Submatix developed and patented Pro Con connectors are simple to use Simply push together until the safety ring closes NOTE The safety ring should make an audible click when engaging The rings are colour coded and the matching of colours should be carefully observed by assembly Press lo Upen D Ring QD Fig 7 Pro Con connector IART 2008 45 E 1 Components of the breathing loop IART SUBMATIX 100 ST SCR User Manual In addition to paying attention to the correct flow direction of the breathing hoses you also need to ensure that the mouthpiece sits in a comfortable position
70. into the counterlungs to prevent them from collapsing fully and thereby hindering gas flow In terms of volume the significantly smaller exhale counterlung is fitted immediately in front of the absorber canister The exhaled carbon dioxide rich breathing gas that is collected here can in the case of an overpressure situation such as IART 2008 47 1 Components of the breathing loop IART SUBMATIX 100 ST SCR User Manual the expansion of gas on ascent be vented via the user adjustable over pressure valve In this way rather than the fresh oxygen rich gas only the low grade used gas will be lost from the loop Simultaneously the OPV serves as a water trap as condensed water from the counterlungs will also be expelled when the valve opens Via the constant flow supply and the ADV bypass fresh breathing gas finds its way from the Nitrox cylinders into the inhale counterlung where it mixes with the already present recycled and via absorber filtered gas To ensure a reliable control of the resultant loop mix Submatix recommends the use of the Oxyscan oxygen partial pressure monitor which uses a sensor positioned in the inhale counterlung The absorber cartridge The absorber scrubber cartridge contains soda lime granulate responsible for the processing of the breathing gas by which the chemical absorption of the carbon dioxide takes place See Module D17 page 32 The scrubber cartridge is connected to the loop betwee
71. ion to O2 consumption Exposure time limits Oxygen partial pressure and exposure time limits NOAA CNS and OTU values CNS recovery factors EAD tables OTU table for multiple dives Dosage nozzles and maximum operating depths Tolerances for constant flow dosage Maximum duration of the constant dosage and the resultant loop mix 2 in relation to oxygen consumption EAD tables FiO in relation to oxygen consumption CO absorption SPHERASORB MOD for Nitrox mixes SCR formula Useful tables Useful formulae Diagrams 1 6 00 J O O1 BB ND 10 11 12 Tables Formulae 1 2 3 IART 2008 IART SUBMATIX 100 ST SCR User Manual Foreword Foreword The stillness iS a silence which opens human s eyes and ears to another world Dear divers For good reason you can hear from nearly every diver who has already dived with a Rebreather how wonderful the peaceful bubble free floating through the underwater world can be Though not new in concept this particularly quiet way of diving is redefining our sport by allowing us to gain a more intensive perception of nature The pros of rebreather diving are irrefutable arguments for a constantly growing fan club spread around the globe The prerequisites for taking up this sport are in addition to the right mental attitude a well trained and safe approach to the handling of such fascinating equipment You have already made the most important first step in t
72. is a raised level of CO in the blood When diving with OC equipment it is typically caused by skip breathing poorly maintained regulators or high levels of exertion The atmosphere contains only 0 00033 bar CO As we metabolise oxygen and produce CO as a by product the partial pressure of CO in the bloodstream increases triggering our desire to breathe When the blood pCO exceeds 0 02 bar we react with an increased breathing rate which flushes the CO quicker from the tissues and at the same time increases the oxygen supply Should a pCO of 0 1 bar be reached dizziness headache and a general unwell feeling will occur By 0 15 bar breathing will be so rapid that it is no longer controllable and cramping can occur After a number of minutes this will lead to unconsciousness False breathing technique or increased activity levels will aggravate these symptoms Because the rebreather diver exhales his used gas back into the loop the CO must be chemically extracted to avoid hypercapnia occurring The necessity for this process raises the inherent risk that the CO level could rapidly climb if for any of a number of reasons this chemical extraction does not take place Hypercapnia can occur in a rebreather when the absorber is gt Too wet or already exhausted gt Insufficient or even absent gt Incorrectly packed too little or too loosely packed absorber leads to gas channel formation and inadequate CO filtration gt
73. lar Nitrox mix it is first necessary to find the equivalent air depth EAD With the EAD standard air tables e g Deco 2000 can be used to read off the no stop time To determine the value FiN the following table can be used By assuming that the nitrogen content in the loop gradually climbs above that contained in the supply cylinder e g through diffusion out of body tissues we will always be on the conservative side when calculating no stop time Nitrox mix a sie Dosage l min l min 0 75 3 0 73 Oo 27 N2 80 Oo 1 25 3 0 66 Oo 94 No 2 25 3 0 20 2 80 No 0 75 5 0 53 Oo 47 No 60 2 1 25 5 0 47 O2 53 No 2 25 5 0 27 O2 73 N2 0 75 6 0 43 O2 57 N2 50 O2 1 25 6 0 37 O2 63 N2 2 25 6 0 20 2 80 No 0 75 10 35 2 65 No 40 2 1 25 10 31 2 69 No 2 25 10 23 Oo 77 No 0 75 15 38 Oo 62 No 32 Oo 1 25 15 26 2 74 No 2 25 15 20 2 80 No Table 13 The EAD can be determined using the formula below FAD 0 40 Example Using 50 Nitrox a dive to 20 metres is planned The oxygen consumption level is 1 25 l min The EAD can be calculated as follows IART 2008 67 E 3 Dive planning IART SUBMATIX 100 ST SCR User Manual 0 63x 20 10 10 13 92 m 0 79 EAD That means that a dive to 20m using Nitrox 50 and with an oxygen consumption level of 1 25 l min has a no stop time equivalent to an
74. lenish the volume The cycles begins anew see Fig 3 below Excess gas does not occur Although the nitrogen content in the breathing gas is initially insignificant assuming the loop has been previously flushed according to manufacturer s instructions it increases during the dive due to the desaturation of diffused nitrogen in the body tissues In intervals of approx 20 minutes or more frequently during strenuous activity and raised respiratory minute volume RMV the loop must be completely flushed to prevent the danger of oxygen starvation occurring If the system is functioning correctly then the loop is constantly supplied with fresh oxygen via the demand valve Higher levels of O2 consumption cause the demand valve to open more frequently thus shortening the available dive time General principles of how a closed circuit O rebreather functions Mouthpiece with one way Valves Demand Valve Pressure Reducer Matte tetes 2 0 EKKO OO OOO IDOE Manometer Q Absorber Canister Fig 3 10 IART 2008 IART SUBMATIX 100 ST SCR User Manual D4 General principles of OCCR functions Possible problems with oxygen rebreathers are CO toxicity due to faulty or exhausted absorber Oxygen starvation can occur if impure oxygen is used or Through inadequate flushing of the loop Oxygen toxicity if the very limited depth range is exceeded Advantages of a closed circuit oxygen rebreather o Low weig
75. lubricate with approved Masel Never use silicone grease or oil on parts exposed to high pressure _ SA RTE 1 fk 0 2 2 s r s Tip Between two dives performed on the same day it is not essential to renew the absorber if the elapsed time allows enough residual usage to perform the second dive Equally disinfection between two such dives can be omitted if the same diver will be using the unit for the second dive Important As the breathing loop provides ideal conditions for almost all types of bacteria to flourish some will undoubtedly take hold unless regular disinfection is carried out By using transparent material for the counterlungs it is easy to visually check for signs of contamination After each diving day the unit should be rinsed thoroughly disinfected and allowed to dry Storage should be in an appropriate cool dark well circulated environment All Pro Con snap connectors should be checked and if necessary lightly lubricated Molykote Self assessment quiz E10 1 Why is it important to disinfect the unit at the end of each diving day E10 2 Why should the cylinder valves be closed directly after the end of the dive E10 3 Must the loop be disinfected after every dive E10 4 Which disinfectants are appropriate IART 2008 85 E 11 Emergency procedures problem solving IART SUBMATIX 100 ST SCR User Manual Module E 11 Emergency Procedures Exercises and P
76. lung is situated within the inhale counterlung to reduce WOB This concept was developed and patented by Submatix 91 Absorber Bail Out Breakthrough Bypass ADV Canister Caustic Cocktail Closed circuit CNS loading CNS toxicity CO Constant flow Co axial Counterlungs IART 2008 IART SUBMATIX 100 ST SCR User Manual Diluent supply valve an open circuit bailout regulator incorporated in the loop mouthpiece Half life recovery factor used to calculate the percentual reduction of the CNS loading in relation to surface interval time An increase in the COz concentration pCOz in the blood above the normal level of 45 mm Hg caused by breathing CO rich gas Excessive O at cell level Condition where O starvation occurs in body tissues All mechanical components of the breathing circulation including counterlung s convoluted hoses canister and mouthpiece Additionally the divers own respiratory system and the air space within the mask Maximum Pressure Select System A gas switching block designed and patented by Submatix National Oceanic and Atmospheric Administration A conventional regulator used as emergency back up Gas is breathed only once and then lost to the surrounding water Partial pressure of oxygen Hose connection system designed and patented by Submatix Semi Closed Rebreather see Semi closed A quantity of the loop gas is periodically vented via an o
77. mains constant IART 2008 63 E 3 Dive planning IART SUBMATIX 100 ST SCR User Manual Applying the same to the oxygen content Vs FsO Qvx FiO VO Due to the constant flow of gas to the loop some of the oxygen not consumed by the diver will be vented via the over pressure valve As Vs und VO are known values Qv can be replaced by them Vs x FsO Vs VO x FiO VO The SCR Formula With the aid of this formula it is possible to calculate the reduced O content in the loop Due to oxygen consumption this will always be lower than the oxygen level in the carried gas cylinder Vs 502 VO FiO Vs VO2 FiO Fraction of inhaled oxygen Vs Volume of the gas flow in L min FsO gt O content in the Nitrox mix VO Volume of oxygen consumed in L min Vs x 2 Qy x Filr Vs x FsO Voe Fig 11 64 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 3 Dive planning Example How high is the loop oxygen content given a Nitrox 32 gas supply a chosen flow rate of 15 0 I min and a high work load on the diver resulting in an oxygen consumption level of 2 L min Given FsO 0 32 Vs 15 0 l min VO 2 0 l min 0 322 15 0 _ 02 0 215 22 2 15 0 2 In this scenario the diver would breathe an almost air like gas with 22 Oz content Thereby we find that this combination of Nitrox mix flow rate and high oxygen consumption still guarantee
78. matix dive planner that is to be found on the accompanying CD 70 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 3 Dive planning Calculating the Required Bail Out Gas Supply Although semi closed rebreathers work very reliably due to their entirely mechanical components and demonstrate very efficient values in regard to the potential dive time it is still necessary to consider an alternative gas supply to ensure that you carry enough gas to cover emergency situations that could arise for yourself and or for your buddy This is usually a familiar open circuit configuration Here the decisive factor is the amount of gas necessary to enable a controlled ascent from the maximum depth gt witha maximum ascent rate of 10 metres per minute The average gas consumption for an experienced diver usually lies around approx 10 to 25 litres per minute If a switch to an alternative gas supply and an ascent under otherwise normal circumstances is involved then gt at least 25 Litres per minute should be calculated If the situation causes panic gas consumption will increase significantly and could reach as much as 90 l min It is up to each diver individually to determine his own personal level for the gas calculation To raise the safety margin we will therefore assume a level for the complete ascent equivalent to a gt gas consumption of 25 l min at maximum depth To take a further safety factor into account the ascent
79. n Conversely the higher pressure in the counterlungs increases exhalation resistance Counterlung s situated on the back provide for increased inhalation resistance due to the negative hydrostatic pressure Conversely the lower pressure in the counterlungs reduces exhalation resistance Vertical swimming position head up or head down Gas in the counterlungs whether on the chest or back of the diver rises to the highest point possible leading to a slightly negative hydrostatic pressure compared to the divers lungs Inhalation effort increases and exhalation effort decreases accordingly However this is less noticeable than the effect experienced with an OC regulator Regardless of position almost no hydrostatic change in WOB is experienced with counterlungs that are positioned over both chest and back Loop Volume A further criterion for optimising breathing comfort is the actual counterlung volume which should only be enough for 2 3 deep breaths before emptying If the volume is too high either due to an incorrectly adjusted over pressure valve or a fast reduction of depth the WOB will increase In contrast an empty counterlung caused by a too lightly adjusted valve by descending too fast by leaks in the loop or by gas loss through frequent mask clearing results in discomfort due to increased inhalation resistance The CO2 absorber also influences WOB By its nature it increases WOB but this increase is held within tolerable limits pr
80. n form are binding All IART instructors must abide by current IART standards as laid out in the Instructor documents available in the members download centre when certifying students 4 IART 2008 IART SUBMATIX 100 ST SCR User Manual B Course objectives C Certification B Course Objectives The aim of this course is to train the participating Submatix diver to Become a knowledgeable disciplined diver well informed on the use of semi closed rebreathers in respect of e The physiological factors e The possible dangers and mistakes e The dive planning e The handling of equipment e The practical dive conduct Using up to date education aligned with the currently accepted methods and guidelines This objective will be achieved through both theoretical and practical training modules 6 Assessment and Certification The course participant proves through completion of a written exam that he she has gained the necessary knowledge to dive with the unit safely Through open water assessment dives the participant proves his her competence in equipment preparation use control in emergency situations and care and maintenance of the unit following the dive Successful completion of each section of the training will be documented on the quality control forms found in appendix IV Should the participant fail to achieve any of the defined objectives or demonstrates conduct that could jeopardise his her own safety the instruct
81. n the counterlungs in order to ensure that the exhaled gas flows directly from the exhale lung and through the soda lime before returning to the inhale counterlung The scrubber tank of the Submatix rebreather has a maximum capacity of 1 7 kg of soda lime It is manufactured from synthetic Plexiglas material a material chosen for its low thermal conductivity and its transparency The insulation property hinders the cooling of the soda lime which increases the effectiveness of the absorption process The transparency is convenient for the post dive control as it allows you to check for water ingress and for the colour indicator without needing to disassemble the unit If using Spherasorb the colour of the granulate changes to lilac when exhausted However it is important to remember that this colour shift only remains visible for a relatively short time around 60 minutes Beyond this time the colour vanishes again but the soda lime does not regenerate Once exhausted it remains exhausted Absorbents that can be used Nowadays there are many suitable absorbents Divesorb Sofnolime Soda Lime Spherasorb and others but they all vary slightly in their properties It is therefore wise to stick to the product s recommended by the manufacturer of the rebreather as the unit will usually have been adapted to suit the properties of the chosen chemical E g grain size dust formation effective performance time heat production etc
82. n the maximum available dive time for the given total gas supply In relation to this the elapsed time of the absorber must be taken into account Finally the no stop time can be read from the Nitrox tables Alternatively with the aid of the SCR Formula the EAD can be calculated and the no stop time can be read from standard air tables Diving with the Submatix SCR 100 ST The following factors need to be considered when planning a dive 1 Max operating depth MOD 2 Best MIX MOD Resulting from Nitro x mix 4 Constant flow nozzle Water Temperature 5 Absorber Elapsed time Gas supply 6 Gas supply lire bar 7 EAD and no stop limits Oxygen consumption 8 CNS loading Constant flow Absorber duration Tigger EAD pressure for ADV CNS toxic ity Max Dive time Fig 9 To commence the dive plan the diver must be clear about the maximum depth that he wants to reach during the dive Based on this decision the best Nitrox mix can be filled Subsequently the correct dosage nozzle for the prepared mix can be fitted according to the table overleaf IART 2008 61 IART SUBMATIX 100 ST SCR User Manual E 3 Dive planning The choice of constant flow nozzle determines the maximum flow times Max duration of the constant dosage 4 It 300 bar Res 30 bar 339 min 339 Max duration of the constant
83. necessary gas loss a deterioration in breathing comfort Self assessment quiz D15 1 Why is it not possible to adjust buoyancy through breathing control D15 2 Why is it not sensible when swimming over an obstacle to compensate for positive buoyancy by venting the counterlungs 30 IART 2008 IART SUBMATIX 100 ST SCR User Manual D16 Work of breathing Module D16 Work of Breathing WOB On completion of this module you should be able to explain how breathing resistance can vary and why the position of the counterlung s affects the work of breathing The breathing resistance of a rebreather changes noticeably dependent on the position of the counterlung s in relation to the diver s own lungs and the volume of gas in the loop The best position for the counterlung would be directly against the diver s own lungs as this would avoid changes in the WOB occurring with changes in body attitude As this is not technically possible the counterlung is positioned as close as possible to the hydrostatic axis of the lungs Decisive for the diver who spends most of the time in a horizontal position is whether a position on the back or the chest is chosen This is a dynamic relationship influenced by changes in depth and the position of the diver Normal horizontal position Counterlungs placed on the chest provide for reduced inhalation resistance due to the positive hydrostatic pressure equivalent to approx 10 cms in the water colum
84. ng gas will be vented via the overpressure valve Slow ascents help reduce the amount of bubble formation Correct neutral buoyancy control is essential in this situation the overpressure valve due to its setting and due to an overly fast ascent is unable to vent gas quickly enough it is possible to release unwanted volume and pressure by exhaling through the nose 82 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 9 Dive techniques for Submatix Always observe a safety stop of 3min 5m After the safety stop ascend directly to the surface When the dive is over remove the mouthpiece from your mouth only after the barrel has been closed Immediately afterwards close the cylinder valve to prevent gas wastage Once the cylinder valve has been closed do not breathe from the loop again there is a danger of hypoxia Lie on your back if a swim to the boat or shore is necessary 72 72 0 6 P 6 4 Beware Oz 2 RTE ee 2 FRS 2 Never attempt to swim long distances on the surface breathing coho the loop as this can induce the risk of hypoxia A lt Self assessment quiz ED 1 What checks should be performed immediately after initial descent 9 2 Why should fast descents be avoided 9 3 What problems arise from saw tooth dive profiles E9 4 Why is it necessary that the mask fits extremely well 5 What should be done directly before the start of the dive E9 6 During as
85. nt on the rate of CO2 production in the body and not on the shortage of O concentration in the bloodstream Self assessment quiz D8 1 Where does the exchange of O and CO take place D8 2 What determines the level of oxygen metabolism D8 3 How is the respiratory rate primarily controlled D8 4 What effect does the level of CO have on breathing IART 2008 21 D9 Oxygen Metabolism IART SUBMATIX 100 ST SCR User Manual Module D9 Oxygen Metabolism At the end of this module you should be able to explain the features of oxygen metabolism Oxygen is the life supporting element in all breathing gas mixtures Chemically bonded to haemoglobin oxygen is transported by the red blood cells through the bloodstream to all body tissues During normal circumstances the haemoglobin is approx 97 saturated with oxygen At greater altitudes one can survive on oxygen partial pressures pO as low as 0 1 bar When diving however a minimum pO of 0 16 bar should be adhered to in order to avoid oxygen starvation hypoxia from occurring See module D10 page 23 Under pressure however too much oxygen can also have damaging effects on the body The type of effect is dependant on two factors exposure time and partial pressure Oxygen partial pressures above 0 45 bar lead with onger exposure to pulmonary damage See module D11 page 24 Exposure to levels above 2 0 bar pO leads to oxygen toxicity of the central nervous system CNS to
86. nt to set the overpressure valve correctly It should be set to trigger with the minimum of pressure by rotating fully to the left anti clockwise In this position the best compromise between WOB inhalation volume available and positive buoyancy is established The necessary adjustment is best carried out with the aid of a buddy in a pool or on a shallow platform The overpressure valve should only be set to trigger at higher pressures for dives beyond 20m in depth Due to its construction characteristics the WOB will vary depending on the body attitude of the diver in the water Initial acclimatization to this is best conducted in a pool Due to the exothermic reaction of the absorber chemical as well as the repeated recirculation of the breathing gas it will remain warm and moist This prevents a drying out of the airways and noticeably reduces the loss of body warmth During the dive breathe slowly and relaxed There is no point in breath holding or skip breathing as the constant flow will be unaffected and no improvement in gas efficiency is to be gained from such techniques Pay attention to correct buoyancy and trim Make yourself as streamlined as possible Avoid sudden changes of depth as these could cause loss of buoyancy control Ascent Before beginning the ascent the loop must be flushed in the usual way to safely avoid a hypoxic situation caused by falling pO levels at shallow depths from occurring During ascent excess expandi
87. of consumption dependant dosage Greater maintenance required Higher running costs due to need for O2 sensors and power supply batteries Incorrect gas mixing should the sensors fail 2b Consumption independent dosage using pure and mixed gasses A further gas supply possibility for semi closed rebreathers is constant flow using both pure and mixed gas Two independent systems e g an oxygen and an air supply with two separate needle valves deliver the optimum Nitrox mix for a particular depth Additionally it is also possible to reflect personal requirements and workload factors in the adjustment of the gas flow volume level IART 2008 19 D7 Fresh gas supply and Gas dosage IART SUBMATIX 100 ST SCR User Manual The constant flow setting of each of the needle valves must be made prior to commencing the dive by using an extremely accurate flow meter that is capable of displaying the necessary gas volume in l min Some units even allow for the depth to be reflected in the mix In such cases oxygen dosage is designed to be depth independent whereas the dosage of the inert gas regulated by the first stage intermediate pressure climbs with increasing depth The maximum depth limits are once again governed by the constitution of the inert gas used Advantages of consumption independent dosage Very economical gas usage Almost bubble free Greater depth range Longer no stop times Disadvantages e More complex dive plannin
88. ompletely bind the exhaled CO This leads to a rapid increase in loop pCO A valve that either automatically or manually supplements the constant flow supply when necessary to provide further gas to the loop The container holding the chemical CO absorber Spherasorb Acidic foam created when water comes into contact with CO absorber If inhaled this can cause burning of the mouth and airways Due to the water traps in the rebreather the likelihood of such a caustic cocktail reaching the diver is almost zero A rebreather where gas is only vented on ascent These include oxygen rebreathers and constant pO rebreathers such as the Inspiration CO must be fully absorbed and in the case of constant pO rebreathers electronic sensors are needed to regulate the gas mix in the loop The level of CNS oxygen exposure related to dive time and the gas mix used Toxic effect of oxygen on the central nervous system occurring if oxygen partial pressure is excessively high Carbon dioxide An odourless gas produced as a by product of oxygen metabolism Even small quantities are poisonous CO build up is the breathing trigger not lack of oxygen A constant injection of gas into the loop commonly used in SCR s The flow rate l min is dependant upon the oxygen in the gas supply and is regulated by the constant flow valve On some units this valve is adjustable exchangeable whereas on others the valve is fixed The exhale counter
89. or is obliged to carry out remedial training until the required standards have been met or refuse certification After successful completion of both the theoretical and practical training the participant will be issued the SUBMATIX SCR Level 1 User certification permitting him her to both dive and purchase the unit IART 2008 5 Module D1 History of rebreather diving IART SUBMATIX 100 ST SCR User Manual Part General Theory Module D1 History of Rebreather Diving 1879 Working with the Siebe amp Gorman Company Henry Fleuss constructs a closed breathing system for use in mine rescue 1904 Siebe amp Gorman patent Oxyligth CO absorber 1926 The Draeger Company develop the Badetauchretter a closed oxygen system utilising a breathing lung chemical absorber and oxygen cylinder 1939 During the war years various oxygen rebreathers are developed by the British Italian and German Navies for mine laying and manned torpedo operations 1952 Working with the Draeger Company Hans Hass develops the Kleintauchgerat 138 1953 Appearance of the Leutnant Lund II oxygen rebreather A few of these units can still be found in working order 1969 Draeger launches the semi closed FertigGasTauchgerat FGT 1 onto the market Modified over the years this unit is still used by military mine laying divers 1970 Walter Stark produces the Electrolung the first rebreather controlled electronically However the elec
90. ormal dive tables can be utilised Rex QE 19 0 EAD 0 79 See the EAD Table 8 page 41 The nitrogen content FN can either be read from the table or calculated with the aid of the SCR Formula See page 64 Example A diver with a nitrox 40 mix 60 nitrogen dives to 20m What is the equivalent air depth 0 60 x 20 m 10 10 12 8m 0 79 7 EAD With an equivalent air depth of 13m and the help of an air dive table we can assess that a no stop time of approx 50 mins when using air is extended to around 100 mins The air no stop limit at 13m when using a nitrox 40 mix The above referred to calculations are an intrinsic part of nitrox dive planning and need to be carried out carefully and conservatively to be able to enjoy the benefits of nitrox safely Calculating the OTU exposure A further limiting factor is pulmonary toxicity and here the level of exposure is tracked through so called OTU s oxygen toxicity units One unit represents 1 min of 100 Oz at atmospheric pressure Exposure builds up slowly over a number of days and is seldom significant for an OC diver but may well be a significant factor for rebreather divers using units particularly fully closed models that expose the user to high levels of ppO over longer periods of time The following equation applies gt 1 OTU 1 Min of 100 O at 1 bar Applied to a dive this formula is difficult to deal with without using a pocket calculator
91. ositive pressure bag DAN 2 units are suited for all applications Self assessment quiz 10 T What does the term hypoxia mean D10 2 Below which partial pressure do we speak of hypoxia D10 3 ls the risk of hypoxia depth dependant D10 4 List 3 possible symptoms of hypoxia D10 5 Which of these is particularly dangerous to 8 diver D10 6 What treatment should be applied following a hypoxia incident IART 2008 23 D11 Hyperoxia Pulmonary toxicity IART SUBMATIX 100 ST SCR User Manual Module D11 Hyperoxia Pulmonary Toxicity On completion of this module you should be able to explain the cause and symptoms of pulmonary toxicity the Smith Lorraine effect Generally pulmonary toxicity is of little concern to the average recreational diver It occurs only after extended exposure to a pO in excess of 0 5 bar It would be necessary to complete a series of dives with long decompression requirements over a number of days before the first symptoms would become apparent Even then in comparison to CNS toxicity the symptoms are at most unpleasant rather than life threatening Symptoms are Discomfort in the lungs Inflammation of the respiratory tract Dry cough Shortness of breath Fatigue Shortness of breath and fatigue occur because the alveoli walls thicken and this hinders the normal diffusion of O2 into the tissues Treatment of the symptoms is not usually necessary Recovery will slowly take place by simply brea
92. ot thoroughly understand any aspect covered by this manual please ask your IART instructor for clarification or contact your local SUBMATIX training center This manual will also provide you with the necessary manufacturer s guidelines for maintenance and service These guidelines must be strictly followed to avoid serious injury or death This device must only be used for the purposes specified herein and the security data sheet as well as the product information regarding the use of the carbon dioxide absorber must be strictly adhered to IART 2008 INDEX Page O1 OO A wo NO Oo 8 10 12 14 16 21 22 23 24 25 28 29 30 31 32 34 42 43 44 56 60 73 74 75 76 77 81 84 86 87 87 88 89 90 IART SUBMATIX 100 ST SCR User Manual Foreword Warning and safety information Pre requisites course content and course standards Course objectives Assessment and certification D General Theory History of rebreather diving D2 General observations D3 General principles of how rebreathers function D4 General principles of how closed circuit O2 rebreathers function D5 Principle functions of a semi closed rebreather D6 Gas consumption and efficiency D7 Fresh gas supply and gas dosage D8 Respiration physiology D9 Oxygen metabolism D10 Hypoxia D11 Hyperoxia Pulmonary toxicity D12 Hyperoxia CNS toxicity Paul Bert effect D13 Hypercapnia D14 Nitrogen narcosis D15 Buoyanc
93. oviding the correct absorber is used is correctly packed and is not exposed to excessive moisture or overused See Module D17 Only absorber of the type and quantity recommended by the rebreather manufacturer should be used as this will have been chosen to suit the characteristics of the canister design A further negative influence on breathing characteristics is caused by water ingress into the loop particularly if it reaches the absorber canister High WOB levels cannot be tolerated over long periods of time They lead to shallow breathing as the chest diaphragm tires less effective flow of gas through the absorber and the threat of CO2 retention Self assessment quiz D16 1 Does a change in swim position noticeably affect WOB If so why D16 2 List3 factors that reduce breathing comfort IART 2008 31 D17 Absorber IART SUBMATIX 100 ST SCR User Manual Module D17 Absorber At the end of this module you should be able to explain the purpose of absorber and the possible dangers arising from its use Absorber is cheap life is valuable One of the most important parts of a rebreather is the CO absorber often referred to as the scrubber The gas in a semi or fully closed rebreather only remains breathable if the exhaled CO is filtered out of the loop This filtration occurs by molecular bonding of the CO with a special absorber chemical The canister to hold this chemical is designed by the rebreather manufactur
94. pO level within safe limits at the chosen MOD and to ensure that the counterlung maintains an adequate volume The continuous flow of gas should also be sufficient to avoid the possibility of hypoxia occurring during strenuous activity This constant flow and the fact that on ascent the gas in the counterlung will expand make it necessary to have an over pressure relief valve installed so that excess gas can be vented into the surrounding water On some units this valve is adjustable and the chosen setting affects loop volume and work of breathing WOB The correct setting of the over pressure valve provides an optimum counterlung volume and this in turn keeps breathing resistance WOB comfortable The amount of gas flowing out through the overpressure valve is dependant on the chosen dosage and remains relatively constant but the resulting volume is influenced by the diving depth and this affects the number and size of the bubbles Minimum bubble formation and the quietest venting of gas are therefore to be expected at the maximum depth for the chosen mix Principle Functions of a Semi Closed Rebreather Mouthpiece with one way valves Inhale counterlung Exhale counterlung Demand valve with Flow injector E E gt Over pressure valve RESESSIE SIEIS RRR RKC RICK RIK CPO Pressure Reducing valve Manometer Nitrox Fig 4 12 IART 2008 IART SUBMATIX 100 ST SCR User Manual D5 How SCR s f
95. pact interface is available from Submatix that enables easy adaption of the Uwatec Oxy 2 sensor head to fit the housing of the SCR 100 Rebreather The Sensor can be attached to the counterlung via a Draeger P Con Sensor readings and ambient pressure are transmitted via a pneumatic cable This construction enables individually adapted cable lengths as well as better protection from moisture The use of 2 x 2 dual cathode sensors or 1 x dual cathode and SR 22 Sensor is possible Instructions for installation are available on the service CD HF Interference This is a largely disregarded problem that can affect dive computers that use HF radio waves to transfer data between the oxygen sensor and the computer Should for example calibration be taking place just as a nearby mobile phone logs onto a new network or in the proximity to a radio mast the accuracy of the calibration could be affected This would lead to a series of false calculations and assumptions by the computer including the actual gas mix CNS exposure level MOD and no stop time IART 2008 73 5 Cylinder filling IART SUBMATIX 100 ST SCR User Manual Module E 5 Cylinder Filling When filling the cylinders it is important that the oxygen content lies within plus minus 2 of the fitted constant flow nozzle otherwise hypoxia hyperoxia or even decompression sickness threaten Directly after filling is completed an oxygen analysis should be undertaken and the result
96. perform less effectively and a Calcium hydroxide trace elements reduction in the length of usage is advisable Some rebreathers have well insulated canisters that minimise loss of performance due to cold water All of these factors make it difficult to exactly determine the effective filter duration Numerous tests have also demonstrated that even under identical controlled conditions quantity temperature pressure packing density and CO content the duration prior to CO breakthrough can still vary greatly A further variable is the level of CO production 32 IART 2008 IART SUBMATIX 100 ST SCR User Manual D17 Absorber This varies from diver to diver and from day to day whereby the level of exertion plays a significant role The higher the workload the greater will be the O consumption and therefore the higher the CO production rate Therefore it is wise to plan very conservatively and to always observe the manufacturer s recommendations see Module E7 page 76 CO breakthrough during a dive can occur for a number of reasons e Incorrectly packed canister channelling e Exhaustion of the chemical due to high exertion levels e Use of contaminated wet or already used chemical e Overextension of the scrubber duration guidelines e Incorrect absorber chemical Irrespective of cause the result will be hypercapnia At the first onset of hypercapnia symptoms bail out to open circuit immediately and terminate the dive
97. quences thereof D17 4 What is a caustic cocktail and how can it happen IART 2008 33 D18 Basic physics review IART SUBMATIX 100 ST SCR User Manual Module D18 Basic Physics review On completion of this module you should be able to calculate the limits of nitrox as a diving gas A few important gas laws need to be considered 1 bar 1 bar e Atmospheric pressure at sea level e Per 10m water column we add IR IR The sum of the above gives the absolute pressure P Therefore in a depth D of 30m the absolute pressure P is 3 x 10m water column 3 bar 1 bar atmospheric pressure 4 bar Written as an equation we have D P 5 1 absolutepressurdbar Example What is the absolute pressure in 27m depth P 3 7 bar 10 The equation enables us to determine the absolute pressure for every depth This is important as we must later calculate the partial pressure of the breathing gas at any given depth In reverse we can also find the depth for a given absolute pressure P 1 10 depth Example At what depth is the absolute pressure 2 4 bar 2 4 bar 1 x10 14m For nitrox diving we also need to consider Dalton s Law This states that the total pressure of a gas is the sum of the partial pressures of its constituent gases In the case of our atmosphere 79 nitrogen and 21 oxygen at sea level the partial pressures are 0 79 bar nitrogen and 0 21 bar oxygen respectively Thu
98. ressure of 0 45 bar that is a 45 O content at sea level without ill effect Above 0 5 bar pOs and dependant on the actual pO level exposure time and exertion level the pulmonary system and the central nervous system can be adversely affected At rest we can even withstand a pO in excess of 2 bar for short periods of time Tests carries out by the National Oceanic and Atmospheric Administration NOAA show that our tolerance reduces with greater exertion exposure to cold temperatures and other physical factors such as an elevated CO level The tests resulted in a now widely used table of safe time limits for various pO levels These exposure limits are only guidelines Sensitivity to raised pO levels varies from person to person and day to day Exposure times should be reduced with higher than normal exertion levels Therefore generally a maximum partial pressure of 1 4 bar is advisable and this should only be exceeded in instances where pN2 is otherwise unacceptably high 1 6 bar should be regarded as the absolute limit for recreational diving To calculate the CNS loading more accurately see example 1 on page 37 and Table 6 on page 38 where the CNS values are given in percentage IART 2008 25 D12 Hyperoxia CNS toxicity IART SUBMATIX 100 ST SCR User Manual The symptoms of oxygen toxicity can be remembered with the aid of an acronym CONVENTID CONvulsions Muscular spa
99. roblem Solving At the end of this module you should be able to determine whether a problem can be solved during the dive and if not what emergency measures should be taken Attention Safety routine If a problem occurs during a dive the following rule applies Close the mouthpiece and switch to OC bail out fin doubt bailout Loss of the mouthpiece Should you lose the mouthpiece underwater it will float upwards In this case lean back look up and locate it then replace it As in this circumstance the mouthpiece was not closed some water may have entered the loop Breathe in carefully at first and listen for gurgling noises If gurgling can be detected it is safest to switch to open circuit and terminate the dive However due to the integral water traps some water can enter the loop without disrupting the function of the unit Vomiting under water Vomiting into the mouthpiece could block the breathing hoses If you find it necessary to vomit under water switch to open circuit first and retain regulator in mouth to avoid swallowing water Don t forget to close the mouthpiece prior to switching to OC Flooded Loop Close mouthpiece and switch to open circuit bail out Exhausted Absorber A raised breathing frequency without any obvious exertion may indicate that the absorber is exhausted See module D13 Hypercapnia page 28 Close mouthpiece and switch to bail out system 86 IART 2008 IA
100. s P 0 79 bar pN 0 21 bar ppO 1 0 bar Note The partial pressures of O pO N pN give the absolute pressure P 34 IART 2008 IART SUBMATIX 100 ST SCR User Manual D18 Basic physics review The partial pressure of a gas has a decisive implication for the diver as it has physiological and chemical effects on the body Usually we know the fraction of the gas FG in the mix we plan to breathe i e the of each gas in the mix In the case of air this is 21 Ono As the effects of any gas depend not on its constituent but rather on its partial pressure PG we must determine a depth to assess the PG and its affects A simple equation can be used PG FGxP Example What partial pressure of oxygen occurs in air at 40m depth 5 bar absolute PG 0 21 5 1 05 bar This equation can be applied in the same way to nitrogen or other gases such as carbon dioxide Dalton s DIAMOND KOAA The so called Dalton s Diamond simplifies finding the solution to the following questions 1 How do find the best mix for a given depth and given 7 By calculating FG 5 PG FG x P Partial pressure fraction of gas x absolute pressure 2 How do I find my MOD By calculating P for a given ppO level P Pg Fg Absolute pressure Partial pressure fraction of gas 3 How do determine my O exposure limits By calculating ppO PG FG x P Partial pressure fraction of gas x absolute pressur
101. s sufficient oxygen even in shallow water Consider what would happen if we were to use compressed air 21 Oz under the same circumstances FsO 0 21 Vs 15 0 l min VO 2 0 l min Fio 15 0 0 21 2 _ 0 09 9 0 02 15 0 2 Note In shallow water this would be an absolutely hypoxic mix The FiO calculated through the SCR Formula is needed for dive planning In the plan shown we can see that this FiO value is used for our EAD calculation Thereby we always assume a VO of 2 5 I min which represents a very high load In so doing we will always remain on the conservative side with the calculation of our no stop time Example How high is the oxygen concentration in the loop if using a Nitrox 50 premix and with a constant flow setting of 6 5 l min the diver has an oxygen consumption rate 1 5 I min _ VsxFO2 V02 FiO Vs 02 Fjo 6 5X0 5 1 5 6 5 1 5 FiO gt 0 35 or 35 O IART 2008 65 E 3 Dive planning IART SUBMATIX 100 ST SCR User Manual What happens however if the oxygen consumption climbs to 2 5 l min Fjo 6 5X0 5 2 5 6 5 2 5 FiO 0 187 or 18 Op This shows us that even under a heavy work load a Nitrox 50 mix will ensure at least 18 oxygen in the loop What FiO results when we mistakenly use a Nitrox 40 mix with the constant flow nozzle designed for a Nitrox 50 mix Initially let s assume that the oxygen consumption rate lies around
102. should not empty the cylinder entirely At the end we should have gt a reserve of 20 in the cylinder Taking the above factors into account we arrive at the following calculation for the bail out gas quantity Given Find the Ascent rate 10 m min Ascent time RMV 25 l min Gas supply in litres incl a 20 reserve Depth 40 m 5 bar Cylinder size Solutions PA gt Ascent time depth 4mins ascentrate gt Gas required Gas consumption x ascent time x absolute pressure 25 x 4 min x 5 bar 500 litres gt 20 reserve ae Sas Supply NINES x100 200 x100 625 litres 80 80 gt Cylinder size iolaidesrequited bea Bae 3 125 litres cylinder pressure 200 bar As can be derived from this example we need at least a 3 litre cylinder as bailout supply better still 4 litres if further gas is to be used for buoyancy compensation or drysuit IART 2008 71 E 3 Dive planning IART SUBMATIX 100 ST SCR User Manual 300 bar cylinders would prove advantageous here as with the same size cylinder the available gas reserve is increased Safe diving with rebreathers demands an adequate bail out supply To calculate this requirement the following must be ioken into account Raised respiratory minute volume The maximum depth The from the above resulting gas quantity nebded for an i emergency ascent to the surface The additional gas needed for buoyancy control
103. sms affecting the whole body in chronic and tonic phases Vision Tunnel vision Ears A ringing sensation Nausea Vomiting may occur Twitching Often in the cheek lip or eye muscles Irritability Dizziness General loss of orientation Although the diver should be aware of the symptoms they may not occur in this order they may not even occur at all Therefore they should not be relied upon as an early warning Even if they do appear it may already be too late to prevent convulsions and in many cases there will be no warning before convulsions and sudden unconsciousness occur Watch out for warning symptoms such as nausea thumping heartbeat and fast shallow breathing If you detect such symptoms an immediate reduction of the Oz partial pressure by switching mixes or bailing out and an immediate ascent is the only way to prevent the situation from becoming life threatening At this point be reminded of the importance of buddy diving As has been shown in the past only a dive partner can prevent such a situation from turning into a fatal accident r f i r f i r Note Oxygen convulsions Similar to an 7 fit can occur without warning if safe 2 levels are exceeded Should convulsions occur it takes several minutes following the discontinuation of excessive oxygen for the symptoms to subside The likelihood of a CNS hit varies from person to _person and from day to day There are other contributing factors
104. ssembly and the failure to carry out pre dive pressure tests or major mistakes by the user underwater could lead to water coming into contact with the absorbent A burning sensation in the throat a soapy taste sudden coughing spasms or other breathing problems could all be symptomatic of such a caustic cocktail The dive should be terminated immediately and the ascent made with OC bail out Afterwards the mouth should be rinsed with fresh water The inhalation of cortisone sprays can help to prevent more extensive lung damage from occurring In any event a doctor should be consulted as a safeguard against consequential injury The unit after thorough rinsing and disinfection and once any leak has been remedied can be put back into service 50 IART 2008 IART SUBMATIX 100 ST SCR User Manual E 1 Further components of the rebreather Further components of the rebreather The components of the rebreather which work under ambient pressure are those which come into contact with our breathing cycle The components that are exposed to high pressure are the gas cylinders that provide the breathing supply the pressure reducing first stages and also the pressure gauges The first stages are responsible for reducing the pressure usually around 200 bar to a constant middle stage pressure depending on the type of unit somewhere between 9 and 17 bar above ambient The intermediate pressure components are responsible for the fresh gas s
105. t back to Submatix before using the rebreather independantly IART 2008 107 IART SUBMATIX 100 ST SCR User Manual v Dive site 9 Time start of the dive REBREATHERTECHNOLOGY Submatix SCR Dive Log Dive data RG _ SE _h min 1 Osoid _ 1 1 Ores Nitrox Mix O2 No PPOsmax 1 4 bar max MOD __m __ min Vbare __ _ bar max V min O low O normal O high gt share of O2 from table O2 Ss Nb planned Actual D m D m EAD _m EAD m NDL RNT NDL RNT _ min 20 0 min min 0 0 min RestNDT min RestNDT min time min time min RG RG 0 0 0 IART 2008 Empty page Name Location Date Buddy Repetitive dive group RG gt before the dive Surface interval SI 55 6 CNS Ontime multiplier CNS Ocrest Gas mixture premix gt share 102 with it MOD Acceptable partial pressure of 2 gt max length of stay at ppO2max Maximum operation depth depth to switch gt MOD table Constant dosage f gt max dive time Gas supply Q gt Q Vunt Punt Preserve Maximum dive time gt tmax Q f Effort gt Gas mixture in breathing bag Gas mixture in breathing bag gt share fN2 with EAD Dive Dive depth D Bottom mix diluent gt ambient pressure pa Equivalent air depth gt EAD Table No decompression limit NDL Residual nitrogen time RNT gt determined
106. t quiz D6 1 Which two factors determine gas consumption when breathing open circuit D6 2 Which factor primarily determines the gas efficiency of an SCR D6 3 What determines an optimum use of the gas supply D6 4 Which type of rebreather offers the best gas efficiency IART 2008 15 D7 Fresh gas supply and Gas dosage IART SUBMATIX 100 ST SCR User Manual Module D7 Fresh Gas Supply and Gas Dosage On completion of this module you should be able to explain the particularities of the fresh gas supply and the gas dosage control 7 1 Fresh Gas Supply There are a number of possibilities of providing fresh gas to consider manual constant flow and demand flow Manual fresh gas supply Here the diver supplies the loop according to his needs by manually injecting gas from the carried gas cylinders The technique demands a solid training and permanent observation of the loop mix in order to prevent oxygen starvation from occurring Constant flow fresh gas supply Here fresh gas flows into the loop through fixed or adjustable needle valves at a steady rate throughout the dive The rate of constant flow necessary depends on the oxygen content of the gas and from the actual oxygen consumption rate of the diver The gas flow must be set high enough to ensure that sufficient fresh oxygen is provided even if the consumption rate of the diver climbs due to greater exertion and even in shallow depths Under no circumstances should the loop
107. t to oxygen starvation and can endure longer before suffering damage When we inhale atmospheric gas passes via the airways into the lungs where it comes into contact with the alveoli the interface separating it from the bloodstream Here via a thin membrane wall O diffuses from the inhaled gas into the bloodstream and in exchange CO diffuses from the blood back into the lungs and ultimately back into the ambient environment The surface area of the alveoli involved in this gas exchange can encompass in a full grown adult as much as 100 to 200 m From the 21 atmospheric oxygen inhaled only a small amount is actually passed through the alveoli into the blood The greater part of the inhaled oxygen is simply exhaled again Approximately 80 82 of the dissolved oxygen in the blood is metabolised and converted into carbon dioxide metabolic conversion rate This carbon dioxide waste is expelled with each breath If now through increased workload a great deal of oxygen is metabolised the rate of CO production will similarly climb It is directly related to the actual oxygen consumption level The result is an increase in ventilation frequency to enable the produced CO to be exhaled and to provide the body tissues with a fresh supply of oxygen The respiratory rate is primarily governed by the blood CO level and only to a much lesser extent by the blood O2 content Thus the frequency with which we breathe depends to a great exte
108. ter Refill the absorber canister before diving This should be done only shortly before the dive commences Storing an already filled canister is not permitted Before filling ensure that the two sieves are not clogged Do not allow residual absorber dust into the cartridge when filling This can permeate through the protective sieve and enter the counterlung Protect the filled canister from exposure to excessive heat Dried out chemicals have reduced capability to absorb CO2 Always adhere to the manufacturers recommendations IART 2008 77 E 8 Equipment preparation IART SUBMATIX 100 ST SCR User Manual Convoluted Hoses To check the correct function of the non return valves hold the not yet mounted hoses green with closed mouthpiece barrel to the mouth and blow air through the hose in the correct flow direction Non return valves open the air flows through OK Then repeat this from the other end red blowing air against the correct flow direction Non return valves remain closed no gas flows through OK To check the correct assembly we use the following pressure tests Pressure test exhale counterlung Use a rubber stopper to seal the exhale connector to the absorber canister Then perform the following tests If the tests reveal a leak you should not dive with the unit until the cause is found and remedied Positive pressure test exhale counterlung only for old coaxial configuration
109. the 3 Weight buoyancy and trim check 4 Bubble check partner 5 Short swim with buoyancy control exercises 6 Adopt differing body positions Note effect on WOB 7 Close and remove mouthpiece replace clear and open 8 Overhead recovery of mouthpiece 9 Bail out open circuit in board gas 11 Trigger the bypass valve Rescue technique Simulation unconscious diver Flush the 12 diver s loop with diluent whilst simultaneously venting excess gas via the overpressure valve and securing mouthpiece 13 Controlled ascent by venting expanding gas via the overpressure valve and or through mouth nose 19 Safety stop for 3 min at 5 metres 16 Close mouthpiece and cylinder valve 18 Remove the unit on the surface without aid from partner IART 2008 101 IART SUBMATIX 100 ST SCR User Manual Signature Date Initials Of Instructor exercise Signature Date Initials Of Instructor exercise IART 2008 Signature Initials participant Signature Initials participant APPENDIX IV Quality Control Checklists Quality control open water dive 3 Exercise Pre dive check 3 minute pre breathe Bubble check partner Close and remove mouthpiece replace clear and open Overhead recovery of mouthpiece swimming horizontally Trigger the bypass valve Rescue technique Sim
110. thers Broadly speaking rebreathers are comprised of two gas supply systems e The fresh gas supply High medium pressure system The breathing gas either as a pure gas or as premixed NITROX flows from one or more storage cylinders via a pressure reducing valve and in a closed system a demand valve or in a semi closed system a constant flow dosage into the loop With passive units the injection of fresh gas must be performed manually e The loop Ambient pressure system The breathing gas now passes via a convoluted hose through a gas and watertight mouthpiece into the lungs of the diver The gas flow direction is determined by two one way non return valves mounted one on each side of the mouthpiece These valves also help to keep the respiratory dead space as small as possible The exhaled gas then passes through a loop integrated absorber canister where the now present 4 carbon dioxide is chemically bonded with the absorber granulate During this process the carbon dioxide reacts with the alkaline hydroxide to form sodium carbonate water and as this is an exothermic reaction also heat General principles of how a rebreather functions Fresh Gas Supply Loop High Intermediate Pressure Ambient Pressure Inhale counterlung Flow restrictor Valve Pressure Reducer Cylinder Valve Nitrox oF 4 5090902020 lt Y Exhale counterlung Fi g 2 Overpressure 8 IART
111. thing normobaric air and not diving for a day or two For the rebreather diver the following therefore applies As long as one remains within the oxygen exposure limits pulmonary toxicity will have no damaging effects See module D18 Calculation of OTU exposure Self assessment quiz D11 1 Does pulmonary toxicity usually represent a real problem for the diver D11 2 At what pO level do adverse physical effects begin to become evident D11 3 Is this a factor to be considered during recompression chamber treatment D11 4 List three symptoms of pulmonary toxicity 24 IART 2008 IART SUBMATIX 100 ST SCR User Manual D12 Hyperoxia CNS toxicity Module D12 Hyperoxia CNS Toxicity Paul Bert Effect At the end of this module you should be able to explain the term hyperoxia and the cause and symptoms of CNS toxicity Whereas an OC air diver only needs to think about his no stop time and perhaps his level of nitrogen narcosis the rebreather diver must take other important physiological factors into account The advantages offered by the use of a rebreather require on the other side greater responsibility in the planning and execution of the dive The life supporting oxygen that we normally take for granted can if MOD s are exceeded or the unit malfunctions turn itself very quickly into a lethal gas Hyperoxia is excessive oxygen at body cell level A healthy person can withstand for an unlimited period an oxygen partial p
112. thpiece guarantee a one way gas circulation flow The valves similar to the exhale membranes in a regulator second stage mostly consist of rubber or silicon and should be renewed periodically to ensure a good seal IART 2008 43 1 Components of the breathing loop IART SUBMATIX 100 ST SCR User Manual The exhale hose is connected directly to the exhale counterlung and the inhale hose runs from the inhale counterlung back to the mouthpiece To avoid incorrect assembly the connections are colour coded and have differing thread sizes Green ring denotes Fresh gas hose from inhale counterlung Red ring denotes Exhaled gas from mouthpiece to exhale counterlung The SUBMATIX rotating barrel mouthpiece can be operated with a single hand The barrel has no security rings and is self sealing due to its eccentric construction Due to this construction Submatix has succeeded in putting a mouthpiece at the diver s disposal which is easy to use and simple to maintain Non return valves situated in the mouthpiece of the Submatix SCR ensure the correct flow of gas through the breathing loop Fig 6 Through their design the re
113. tronics prove so unreliable that the unit is withdrawn from the market one year later 1975 The LAR 5 LungenAutomatisches Regenerationssystem an oxygen rebreather is produced and exclusively designated for military special forces activities 1995 The semi closed Draeger Atlantis is launched onto the recreational diver market 1997 Draeger undertake a number of improvements to the Atlantis and relaunch it under the name Dolphin 1998 After undergoing an intensive 6 year development the INSPIRATION closed circuit rebreather becomes available to the recreational diving market 1999 In the same year Draeger launch the Ray Smaller and compacter than all previous SCR models 2004 Aided by an EU development project grant the production model of the Submatix 100 Rebreather achieved a CE rating in April 2004 2008 Submatix now has both SCR and CCR versions of its rebreather available throughout Europe 6 IART 2008 IART SUBMATIX 100 ST SCR User Manual D2 General observations Module D2 General Observations In both recreational and professional diving alike self contained lightweight equipment has become the norm Thereby the parameters of the planned dive determine the amount of gas size and number of cylinders to be carried With open circuit systems the diver receives fresh gas with every breath and releases this gas into the surrounding environment with every exhalation Depending on depth and th
114. uctor Level IIl User course 10 LEVEL II certifications 20 logged hours Level IIl on requisite rebreather Instructor exam LEVEL III SCR CCR Level III course Instructor Trainer Status is individually SCR CCR LEVEL Il DIVER considered and awarded Advanced Trimix 104 IART 2008 IART SUBMATIX 100 ST SCR User Manual Submatix Guarantee IART the International Association of Rebreather Trainers was founded in 1997 after Hubert Stieve and Peter Grosserhode recognised that the growth of rebreather technology in recreational diving was not without great safety risks and organizational problems for the established recreational diver training agencies and clubs Too great was the difference in required knowledge ability und discipline IART has the aim through uncompromising teaching standards to further the use of Nitrox and Trimix and to make rebreather diving as safe as possible Nothing should be left unquestioned The aims and the ways to achieve them must be continually reviewed and adapted IART will closely follow the future development of mixed gas and rebreather diving and continue to make recommendations and promptly adapt training programmes to keep pace with new technology President Chris Ullmann Board of Advisors Chairman N Matthews www iart de Meet other IART divers and catch up with the latest news International Association of Rebreather Trainers Chris Ullmann IART HQ IAR
115. ulation unconscious diver Flush the diver s loop with diluent whilst simultaneously venting excess gas via the overpressure valve and securing mouthpiece OC bail out to off board stage swimming horizontally Return to loop after minute OC Bail out ascent Safety stop for 3 min at 5 metres No ON BIN 17 20 19 Quality control open water dive 4 Exercise Pre dive check 3 minute pre breathe Bubble check partner Close and remove mouthpiece replace clear and open Overhead recovery of mouthpiece swimming horizontally OC bail out to off board stage swimming horizontally Return to loop after minute Rescue technique Simulation unconscious diver Flush the diver s loop with diluent whilst simultaneously venting excess gas via the overpressure valve and securing mouthpiece Controlled buoyant lift of unconscious buddy Ensure casualty is positively buoyant at the surface Perform simulated in water expired air resuscitation EAR One breath every five seconds Instructor should allow student to try various EAR and towing techniques Remove the unit on the surface without aid from partner No NB IN N 12 14 15 18 102 APPENDIX IV Quality Control Checklists 20 103 Dive time Dive time Depth Depth
116. uld be as close to the O2 content of the Nitrox mix as possible This ensures that gas consumption wastage is as low as possible IART 2008 62 IART SUBMATIX 100 ST SCR User Manual E 3 Dive planning Calculation of the FiO loop O content The calculation of the FiO2 can never be accurately determined in advance of the dive as this value is influenced by many variable factors Therefore when planning a dive it is usual to start with known or general figures to establish an approximate value To calculate the FiO value as accurately as possible we use a model that assumes that the diver remains at a constant depth and has a constant work load factor This enables us to use the semi closed rebreather SCR formula The FiO is determined by the following values gt Oxygen content of the Nitrox mix 5002 gt The volume of the fresh gas flow Vs Together these two determine the quantity of oxygen delivered gt Oxygen consumption rate of the diver VO gt Volume of the fresh gas flow residual gas volume used gas volume CP i t Le 2Vs Qv VO oe gt gt V Ao Vs x 2 a A FiO N Qv x FiO Fig 10 In this constant model the oxygen addition and the oxygen loss overpressure valve Qv divers oxygen consumption VO are identical and this means that the loop oxygen level re
117. unction Of particular importance is the correct relationship between the selected Nitrox mix and the appropriate flow valve This is governed by the necessity to guarantee an adequate fresh gas supply even under the most strenuous conditions higher oxygen consumption The resultant intensive and life preserving preparation time needed to calculate this prior to each dive does offer a few advantages It reduces gas consumption and makes longer dive times possible For a diver using a semi closed rebreather with a constant flow of 12 L min and an oxygen consumption of 1L min the use of the breathing gas will be 8 times more efficient than OC Under heavier workload and or increased depth efficient use of the gas supply moves further in favour of rebreathers You can read more about this under Fresh gas supply and gas dosage in module D7 page 16 The potential problems of semi closed rebreathers similar to closed circuit units include CO poisoning hypoxia and oxygen toxicity Advantages of semi closed rebreathers o Improved gas efficiency o Reduced nitrogen uptake o Reduced exhaust bubbles and therefore quieter Disadvantages Actual gas mix in the loop cannot be guaranteed Depth limits predetermined by the choice of pre mix Fluctuations in pO2 level caused by varying activity levels Therefore additional safety margins are necessary when calculating decompression and CNS exposure 0 Self assessment quiz D5 1 Wh
118. upply whether manual constant or via a demand valve The Nitrox cylinders The gas supply for the dive is carried in dual 200 bar 2 litre steel cylinders The basic version of the SCR 100 ST is configured to a Nitrox 50 mix However by fitting one of the alternative flow nozzles other nitrox mixes can be used The cylinders are held in place within the housing by Velcro bands The labels on the cylinders allow more accurate information about the contents to be recorded Nitrox cylinder with label INT VERSION Optionally 2 further 2 litre cylinders can be attached to the unit IART 2008 51 E 1 Further components of the rebreather IART SUBMATIX 100 ST SCR User Manual The first stage pressure reduction valve The first stage performs the task of reducing the high pressure in the Nitrox cylinder to an intermediate pressure of 10 bar Both Nitrox cylinders have their own separate first stages The two first stages are linked together by an intermediate pressure connector in order to ensure a gas supply should one of the cylinders be empty or the valve closed In such a situation gas flows from the other cylinder via the connector into the intermediate pressure chamber of the deprived first stage Additionally both first stages are equipped with separate oxygen compatible manometers pressure gauges each displaying the gas content of the respective cylinder Attached to the left hand first stage there is
119. used as a ppO2 monitor only for checking as variations may occur through humidity and warmth The use of suitable CE certified ppO2 monitors with visual and acoustic warnings is recommended fo x 5 5 hoa 6 P 6 4 haa 2 ensure a trouble free performance from the constant flow valve it is necessary to have a minimum reserve of 30 bar in the gas Always adhere to reserve n 2 3 ea 8 C2 re Any etes or eb of the bypass valve should always be carried out by a Submatix authorized factory technician Self assessment quiz 2 1 With which gas mixes can the Submatix be dived 2 2 Which methods can be used to measure the constant flow rate 2 3 Which parameter determines the choice of the dosage nozzle 2 4 Why is the choice of the correct nozzle so important IART 2008 59 E 3 Dive planning IART SUBMATIX 100 ST SCR User Manual Module E 3 Dive Planning At the end of this module you should be able to conduct a dive plan and calculate all the necessary parameters To plan a rebreather dive where many varying factors each have a decisive influence demands a thorough knowledge of how these factors depend on and influence each other The following diagram presents an overview of the relationships and should aid your planning procedures Planned depth Le Nitrox mix planned analysed max dive time LA DE Fig 8 Th
120. vailable everywhere Cylinder filling more complex Greater care and maintenance demands High initial cost of acquisition Extra cost of absorber The particularities of the various systems will be addressed in the subsequent modules Self assessment quiz D3 1 Name two types of rebreather D3 2 List both methods by which fresh gas can be supplied D3 3 List the components of a rebreather that are not found in open circuit systems D3 4 Briefly describe the flow of breathing gas through a rebreather D3 5 List 3 advantages of a rebreather IART 2008 9 D4 General principles of OCCR functions IART SUBMATIX 100 ST SCR User Manual Module D4 How Closed Circuit O Rebreathers Function At the end of this module you should be able to explain the general principles behind a closed circuit oxygen rebreather Closed circuit oxygen rebreathers e g the Oxylon from Poseidon or the LAR V from Draeger are generally very simple in construction The counterlung is initially filled with oxygen from the cylinder During the dive the oxygen is consumed at a rate dependant on the diver s activity level and carbon dioxide is exhaled The exhaled gas passes through an absorber compound where the CO is extracted by a chemical bonding process The removal of the exhaled CO causes a reduction in loop volume that is compensated for by a demand valve that opens as pressure drops allowing fresh oxygen to flow into the loop and rep
121. verpressure valve and replenished by a constant flow of fresh gas into the loop This guarantees an adequate pO and reduces the chance of a carbon dioxide build up Gas consumption is therefore depth dependant The CO absorber material Commonly used slang for the canister and CO absorber IART 2008 APPENDIX Glossary DSV HLF Hypercapnia Hyperoxia Hypoxia Loop MPSS NOAA OC system pO ppO Pro Con SCR Semi closed Scrubber Stack 92 IART SUBMATIX 100 ST SCR User Manual APPENDIX II Tables APPENDIX Tables 32 15 l min Table 3 Table 4 93 IART 2008 APPENDIX II Tables IART SUBMATIX 100 ST SCR User Manual NOAA Oxygen Partial Pressure and Exposure Time Limits for Nitrogen Oxygen Mixed Gas Dives Single 24 Hour Total Exposure min hr 150 2 5 20 180 3 0 150 180 3 0 180 210 3 5 Table 5 The values have been rounded up for simplicity QUE ARE CNS OTU ppO exposure limit ppO exposure limit Per min Per min 0 Permin Per min Maximum in min Maximum in min _ 0 60 720 0 14 0 26 115 227 0 44 4 0 70 570 0 18 0 47 1 20 210 0 47 1 32 1 25 196 0 51 1 40 1 30 180 0 56 1 48 CNS Half life Factors Interval Time in hrs HL Factor x CNS Interval Time in hrs HL Factor x CNS Table 7
122. x40 FO 2 Example A diver with a nitrox 40 mix does not want to exceed a ppO of 1 2 bar What is the MOD 1 2 MOD 1 20 10 0 4 36 IART 2008 IART SUBMATIX 100 ST SCR User Manual D18 Basic physics review 3 Calculating the O exposure limits Here we need to take into account the CNS exposure tables see Table 6 page 38 for Oxygen limits for the central nervous system As described in module D12 we must not exceed established limits for either the level or duration of exposure to raised ppO Here we rely on the 1990 published tables from the National Oceanic and Atmospheric Administration NOAA NOAA Oxygen Partial Pressure and Exposure Time Limits for Nitrogen Oxygen Mixed Gas Dives 24 Hour Total Exposure min hr 150 2 5 180 3 0 180 3 0 210 35 Table 5 Example 1 We plan a dive to 29m with a nitrox 32 mix What is the maximum 2 during this dive Before we can use Dalton s Diamond we must first establish the absolute pressure at 29m P D 1 eme 3 9 bar 10 10 This can now be used in the equation PG FG P PG 0 32 O x39bar ppO 1 25 bar This value as usual with dive tables is rounded up on the conservative side and in this case a value of 1 3 bar is used in conjunction with the NOAA tables to establish a maximum exposure time of 180 mins This should not be confused with no stop time which is still determined by the nitrogen
123. xample 3 Multilevel dive The CNS limit at a ppO of 1 6 bar is according to Table 5 45 mins But what is the limit when I only spend 20 minutes at 1 6 bar but a further 50 minutes at 1 4 bar 38 IART 2008 IART SUBMATIX 100 ST SCR User Manual D18 Basic physics review In this case we calculate the two parts of the dive as separate values and then add these together 1 6 bar 45min 100 1 4 bar 150 min 100 20 min 20 45 x 100 44 4 50 min 50 154 x 100 32 5 gives 44 4 32 5 76 9 By this multilevel dive we would reach 77 of our CNS limit In Table 6 the CNS loading is expressed in min in order to make the calculation of total CNS exposure easier Dive time x CNS Factor min gives the total CNS loading For a repetitive dive the 24 hour exposure limits must be observed However during a surface interval a recovery factor can be taken into account This recovery factor is still very much a rule of thumb calculation Generally accepted is a halving of the exposure for every 90 minutes interval time e E g A 60 exposure level sinks to 30 after 90 mins and to 15 after a further 90 mins To calculate our CNSpreg loading for repetitive dives this is added to the loading of the next dive we use the CNS half life factors listed in Table 7 These show depending on the length of the surface interval the percentual reduction of the oxygen loading CNS
124. xicity with resultant convulsions affecting the whole body See module D12 Paul Bert Effect page 25 For the sport diver the danger of oxygen lies in its effect on the central nervous system CNS toxicity is a deadly danger that causes uncontrollable spasms which can lead to the diver losing grip on the mouthpiece and drowning Decades of mixed gas diving experience has led to the recommendation that pO should never exceed 1 6 bar Furthermore with raised physical activity and or raised CO levels pO should not exceed 1 4 bar As a general rule the acceptable limits are Self assessment quiz D9 1 Which agent binds O in the blood supply D9 2 What is the most dangerous aspect of oxygen toxicity 09 3 With raised exertion levels the maximum pO should be D9 4 What are the rule of thumb limits for pO levels 22 IART 2008 IART SUBMATIX 100 ST SCR User Manual D10 Hypoxia Module D10 Hypoxia On completion of this module you should be able to explain the causes and symptoms of hypoxia and know when they are likely to occur Hypoxia is one of the limits that we as rebreather divers and as mixed gas divers must very closely observe An inappropriate choice of mix and a shallow diving depth can under certain circumstances lead to an O partial pressure less than 0 21 bar Although the human body can tolerate lower levels they should not be allowed to drop below the absolute limit of 0 16 bar The first signs of an
125. y control D16 Work of breathing D17 Absorber caustic cocktail D18 Basic physics review E Unit Specific Theory E Assembly of the Submatix E1 Components of the breathing loop E2 Gas dosage and constant flow Settings 3 Dive planning E4 Use of dive computers E5 Filling the cylinders E6 Technical data E7 Absorber properties Soherasorb E8 Equipment preparation 9 Dive techniques for the Submatix E10 Post dive care E11 Emergency procedures exercises and problem solving Practical Training Fi Equipment preparation Pre dive checks F2 Practical training CW training Open water training F3 Special hand signals IART 2008 Index A B 0 Part Module Part Il Part Ill IART SUBMATIX 100 ST SCR User Manual Page 91 91 93 99 100 104 105 106 107 108 INDEX Index APPENDIX l Glossary Il Tables Formulae IV Quality control checklist IART Flowchart IART about IART Submatix guarantee Liability statement Submatix Dive log Overview of self contained diving equipment General working principles of a rebreather Working principles of a closed circuit rebreather Working principles of a semi closed rebreather General working principles of the Submatix SCR Loop gas flow Pro Con connector Dive planning Dive planning Oxygen consumption SCR Formula Schematic 100XT Gas efficiency Comparison of dive time limits O2 concentration in the loop in relat
126. y is such a system termed Semi closed D5 2 What happens to excessive loop gas D5 3 List 3 possible problems associated with semi closed rebreather diving D5 4 List 3 advantages of semi closed rebreathers IART 2008 13 D6 Gas consumption and efficiency IART SUBMATIX 100 ST SCR User Manual Module D6 Gas Consumption and Efficiency On completion of this module you should be able to explain why gas consumption differs between SCR and open circuit systems 6 1 Gas Efficiency With an open circuit system the diver is supplied with the required volume of fresh gas related to his breathing rate and the actual ambient pressure The gas consumption is directly related to his RMV and the depth of the dive However as the body s need for oxygen remains relatively constant and largely unaffected by depth the only factor that governs the actual efficiency of gas consumption is the metabolism of oxygen As the following table indicates OC air diving has a low efficiency rating Dive time comparison SCR 100 ST Open circuit 195 E Depth in Dive time in mins SCR 100 ST O Dive time in mins OC system Table 1 Semi closed rebreathers offer the possibility to repeatedly re breathe oxygen rich mixes and thereby greatly improve gas consumption efficiency The higher the O content the more economical the consumption rate will be The best efficiency is gained by closed circuit units 6 2 Gas Consumption Althoug
127. you wish to use your dive computer you must always assume the maximum oxygen consumption level and accordingly the maximum pN level to ensure a conservative decompression calculation An uncritical use of diving computers without regard to the above mentioned facts can lead to false decompression data when diving with rebreathers To fully gain all of the advantages of SCR diving long dive times with shorter but safe decompression the actual loop ppO must be continually monitored Using Nitrox dive computers without oxygen sensors Experience has shown that when using normal Nitrox computers the Nitrox mix programmed into the computer should be 10 less than the premix in the cylinder This ensures that the decompression information reflects real values within acceptable limits The depth limit must be planned before the dive and the MOD strictly observed This technique is based upon the assumption that the diver will have an average oxygen consumption level Using Nitrox dive computers with oxygen sensors If a dive computer is used that has its own oxygen sensor the following tip should be observed Some computers only show and calculate oxygen values of 21 or above e g the UWATEC AirXO If during use a lower loop mix occurs such computers will nonetheless continue to assume a mix containing 21 for decompression calculations and this could lead to an underestimation of decompression obligations Interface for Uwatec Oxy2 a com
128. your IART instructor for further details Course structure The course participant must undertake the training by signing the special liability release form exclusively at his her own risk The training reflects the standards required by the manufacturer of the rebreather IART is authorized by the manufacturer to conduct this training This manual is constantly revised and improved in consultation with the manufacturer to reflect new developments resulting from technical improvements or gained through dive experience You will receive the current edition from your IART Instructor Older editions should not be used The Submatix SCR Level course trains and certifies the user to dive within no decompression limits to the maximum safe depth of the Nitrox mix used Course Overview Theory Presentation e Familiarisation with all rebreather components e Dive planning and execution Nitrox theory e Proof of knowledge written test covering theory dive planning and execution emergency management and rebreather components concludes the theoretical development Practical Training e Equipment preparation care and maintenance e Dive planning and execution e Diving techniques and their application in open water e Emergency management e Proof of successful completion of all required training exercises Certification For this training course the current IART standards manuals and fees listed on the training centre s applicatio

Download Pdf Manuals

image

Related Search

Related Contents

PGP™ Desktop for Windows User`s Guide  PULVERISATEUR THERMIQUE    Avaya BayRS Version 15.2.0.0 User's Manual  BEDIEnUngSanLEItUng - JG Gastro    AS112 User manual - Gold Apollo Co., Ltd  V7 CAT5e UTP Network Cable 2 (RJ45 m/m) blue m  LenacelgaPolvo mojable (WP) HERBICIDA RESIDUAL DE  guide d`utilisation de l`exerciseur elliptique  