Home
Use and Care Manual
Contents
1. monthly basis for any obstructions Disconnect and clear any debris present then reconnect the hose When cleaning the surface of the unit do not use any harsh or abrasive cleaners Additionally do not expose the power cord plug control panel and or motor to direct moisture 10 TROUBLESHOOTING Please check the following troubleshooting tips before calling for assistance PROBLEM CAUSE SOLUTION does not operate outlet Dehumidifier collects Water Low ambient Increase ambient temperature temperature Condensate hose is Check hose for blocked restrictions Difference between set Adjust humidity setting to humidity and current a lesser setting actual humidity is minimal Humidity is too low for No need to run the unit the unit to run Dehumidifier Doors and windows are Seal room from external is operating open areas by closing doors but room is not windows etc drying NOTE If you have tried the above troubleshooting and need additional assistance contact Consumer Services at 877 365 6274 11 ERROR CODES WARNING DO NOT attempt to rectify errors using unqualified personnel To remedy the following errors a qualified professional is required NOTE With any error code it is suggested to turn the unit off wait five minutes and then turn the unit on again If the error code is still present a qualified professional is required to fix the problem SOLUTION DI
2. 200 PINT DEHUMIDIFIER USER MANUAL FOR MODEL PACD200 Before using your commercial dehumidifier please read this manual carefully and keep it for future reference along with your receipt TABLE OF CONTENTS General Information e ec te o 1 Important Safety 2 Str cture Diagram eee oe dt 3 Set pIfiStructions A 4 5 Control Pane li ntn pue dani 6 7 Operating Instructions 8 Maintenance dero n des lia 9 10 Troubleshooting 22 titt eene Leid ee 11 Error Codes i eroe e eL ER M e antes eb ta 12 Purchase Maintenance 13 GENERAL INFORMATION Please DO NOT dispose of any packaging until you have checked that the appliance is operational After removing the packaging ensure the contents are intact and complete In the unlikely event of missing parts contact Consumer Services at 877 365 6274 DO NOT leave children unattended with any of the packaging as it is a potential source of danger Disposal of all packaging must be carried out responsibly safely and in accordance with your local regulations ALWAYS recycle the packaging material where possible Wh
3. 8 The dehumidifier is not intended for use by young children without supervision Young children should be supervised to ensure that they do not play with the dehumidifier 9 Disabled persons and the elderly may require assistance with set up and usage 10 Do not place objects on the product or allow objects to obstruct the inlet or outlet openings do not operate in close proximity to walls curtains etc 11 Use of attachments or accessories not recommended or sold by the product distributor may cause injury to persons or damage to property 12 This product is intended for normal light commercial use only 13 Contact a qualified service technician for repair or maintenance of this unit Do not attempt to dismantle the appliance 14 Do not operate the appliance on a metal surface 15 Do not use the appliance in artificially hot or humid conditions or allow it to be used in a hazardous environment 16 Do not clean the appliance with organic solvent 17 This instruction manual is an integral part of the appliance and should be stored for future reference It must accompany the unit in event of ownership transfer or for reference by a service engineer 2 STRUCTURE DIAGRAM Air inlet panel Back panel Front panel Wheels 8 MA See LS PORRO ISSN SN DS POS nas Handle Control panel Air outlet hood 6 Bolts
4. for securing the handle Power cord Handle cover Es c di Water pipe supporter Water outlet NOTE You will need to install the handle Six bolts are included for the installation WARNING DO NOT OBSTRUCT THE AIR INLET OR OUTLET 422 SETUP INSTRUCTIONS d IMPORTANT Place dehumidifier in the upright position When transporting a dehumidifier to site allow the dehumidifier to stand upright for 30 minutes before switching ON This is necessary to allow the refrigerant system to stabilize and avoid system damage SETTING UP THE DEHUMIDIFIER Operate the dehumidifier in an enclosed area as this creates a drying chamber Close all doors windows and areas that open to external areas to maximize the dehumidifier s water removal efficiency Keep traffic through the drying chamber to a minimum Place the dehumidifier in the center of the room away from walls and furnishings DO NOT allow the airflow to be obstructed Illustration of correct positioning for best performance 4 SETUP INSTRUCTIONS continued DRAINAGE The dehumidifier pump connects to a plastic drainage hose The hose is stored on the back of the appliance Uncoil the entire hose ensuring there are no kinks or restrictions and place the unattached end into a drain or run outdoors Ensure that draining running to the outdoors does not create a hazard that could cause someone to slip Water drains MUST
5. SPLAY cope MEANING READING E1 Coil sensor every Replace coil sensor Call for error 30 seconds replacement part Humidity Flashes every Replace humidity sensor Call sensor error 30 seconds for replacement part Low or no Flashes Turn the unit off wait 5 refrigerant continually minutes and power the unit ON If E3 shows again within 15 mins after turning the unit back on then we can confirm the unit refrigerant leak requires professional repair Call your local HVAC repair shop for assistance Water pump Flashes Dehumidifier will turn OFF fault or continually automatically Check for blockage blockages in the water hose If there are no visible blockages the pump or water pipe may need to be replaced NOTE If the error occurs within one year from the date of purchase contact Consumer Services at 877 365 6274 for warranty assistance prior to contacting a repair person You must have the original purchase receipt for warranty assistance 12 PURCHASE RECORD Purchase Date Serial Number Distributor Tel Damp LAY DEHUMIDIFIER by Perfect Aire Distributed by Perfect Aire LLC 5151 Belt Line Rd Suite 878 Dallas TX 75254 877 365 6274 www perfectaire us Specification and performance data is subject to change without notice Printed in China
6. ance The working performance of the dehumidifier will be greatly reduced if the filter becomes blocked 1 Remove the filter as shown in the diagram below 2 Vacuum any debris from the filter using the vacuum hose and nozzle attachment 3 Using lukewarm water and a mild detergent wash the filter and allow to dry completely 4 Once completely dry re install the filter into the dehumidifier Pull filter out from the left side Air filter MAINTENANCE continued Changing the battery The battery allows the user to check the total working time of the unit even when the unit is powered off Press the button to check this 1 Remove the screws in the four corners of the control panel 2 Once the screws are removed carefully lift the control panel to access the PCB 3 On the PCB is 6F22 9V battery Remove the battery and replace with a new battery 4 Refit the control panel onto the PCB 5 Replace the four screws Battery 6F22 9V Maintenance Notes Check the electrical cord for damage before each use Additionally it is a good practice to check the drain hose
7. be checked regularly when used lt 16 ft NOTE The drain hose for the ejector pump is 25 ft long and can drain up to 16 ft vertically Attempting to push water vertically more than 16 ft vertically may cause water backup in the pump which can result in leakage See image above 5 CONTROL PANEL PURGE DEFROST RUN DEHUMIDIFIER 1 ON OFF Key 5 PURGE Key 2 UP and DOWN Keys 6 HUMIDITY and TIME Display 3 Purging Indicator 7 TIME Key 4 Defrosting Indicator 8 Operating Indicator ON OFF Press the O key to turn the unit ON or OFF PURGE Press the key to empty water from the pump reservoir During normal operation the pump purges automatically when the reservoir is full Use PURGE before moving the machine to avoid water spillage The pump will close automatically after 40 seconds of continuous operation e and Press e and Q keys to set or adjust humidity in the range of 26 and 90 When the environmental humidity is below 26 CO will be displayed Defrost Indicator The unit begins to defrost when the defrost indicator illuminates the unit has stopped defrosting when the light is no longer illuminated When defrosting is complete the unit begins to dehumidify again automatically 6 CONTROL PANEL continued TIME Press this to display working hours and total working time After starting operation the display will show the humidity setting left and current h
8. en using any electrically powered product basic safety precautions should always be followed Please read these instructions carefully and in full before using the product IMPORTANT SAFETY INSTRUCTIONS WARNING to reduce the risk of fire electrical shock or injury to persons or property 1 Always operate the product from a power source of the same voltage frequency and rating as indicated on the product identification plate 2 To minimize shock and fire hazards proper grounding is important The power cord is equipped with a three prong grounding plug for protection against shock hazards Never cut off the third prong 3 Your unit must be used in a properly grounded wall receptacle If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install the proper receptacle 4 Do not use extension cords or an adapter plug with this unit If it is necessary to use an extension cord use an approved heavy duty extension cord only available at most local hardware stores 5 Do not operate this product with a damaged power cord plug If the supply cord is damaged it must be replaced by qualified repair person in order to avoid hazard 6 Toreduce the risk of electric shock do not expose the unit or flexible cord to moisture of any kind 7 Turn off and unplug from the power socket when not in use before assembling or before cleaning
9. s restored Error Messages E1 E2 E3 E4 See the troubleshooting guide at the back of this manual for meanings assistance 57 OPERATING INSTRUCTIONS General Use Press the ON OFF key to turn the unit on It will begin working automatically After use press ON OFF key to turn the unit off Water pump will turn on automatically for 40 seconds to drain the remaining water in the unit then turn off automatically ATTENTION DO NOT switch the power OFF by disconnecting at the main socket outlet To avoid water spillage DO NOT move the dehumidifier for at least 3 minutes after turning the power OFF Key Lock Function If the keys of T and P are pressed for 2 seconds simultaneously the defrost light will continue to illuminate at the speed of 50 Hz and all of the keys on the control panel will lock The control panel can then be unlocked by pressing the T and keys together again for 2 seconds Vent Hose Function To speed up drying in very damp place use a plastic pipe vent hose with a diameter larger than 6 7 inches Attach the vent hose to the exhaust ring see below to expedite drying by directing the heat exhaust toward the wet area Vent Hose not included 8 To clean the air filter Ensure the dehumidifier is turned OFF and the plug is removed from the power outlet before performing mainten
10. umidity right Humidity setting can be changed by pressing Up or Down Time settings are based on minutes For example if the display shows 0000 50 this means that the unit has worked for 50 minutes since powered on If you want to view the total working time press T again and the display will show this for 10 seconds then return automatically to the original working hours Pressing before the 10 seconds can also return the display to the original working hours If the unit is powered but not in operation the LED will not display anything If T is pressed once the working hours from the previous time the unit ran will display for 10 seconds Within the 10 seconds if is pressed again the total working time will display for 10 seconds If there is no action within those 10 seconds the LED will automatically shut off If T is pressed when LED displays the total working time the LED will shut off immediately The current working time will be deleted by pressing and holding down for 5 seconds the time will be reset but the deleted time will be added into the total working time NOTE total working time cannot be deleted If the time is beyond the range of what the LED can show it will be deleted and restart from zero NOTE If a power outage occurs while the unit is powered on the unit automatically resumes operation at the most recent settings when power i
Download Pdf Manuals
Related Search
Related Contents
Service Manual 09/2008 Philips Forecast Bow Sennheiser PMX 60 User Manual 安全・安心に関する活動を行う特定非営利活動法人(NPO Copyright © All rights reserved.
Failed to retrieve file