1. lt MAX lt MAX TC TM When the control panel is used in applications for rolling shutters set JR6 ON connectthe N C limit switches in succession to the motor phases make a jumper with the terminals 0 11 12 13 14 Application example for sectional overhead doors Example 1 When the control panel is used in applications for sectional au tomations set IM MAX connect opening and closing limit switches N C contacts to terminals 0 11 12 select the opening control by means of DIP1 0N select the direction of the movement by means of DIP2 OFF select the closing control by setting 6 4 0FF set JR620N NOTE to use electronic control panel in hold to run mode discon nect terminal 9 In this case the opening 1 5 and the closing 1 6 controls operate only if kept pressed if released the automation will stop Automatic closing and radio remote controls are disabled Example 2 If you have connected the self controlled safety edge SOFAT in closing it is possible to make the following connections set M MAX connect opening and closing limit switches N C contacts to terminals 0 11 12 select the opening control by means of DIP1 ON select the direction of the movement by means of DIP2 OFF select the closing control by setting 64 OFF set SO
2. press the PRG button on the radio receiver or on the control panel the SIG LED lights up make a transmission by pressing one of the desired CH buttons of the transmitter within the range of the radio receiver The transmitter is now stored During this phase the SIG LED flashes When the SIG LED is again lit up it is possible to validate ano ther transmitter Validate all the new transmitters by making a transmission as indicated you automatically exit the procedure 10 seconds after the last transmission or you can press the PRG button again the SIG LED goes off Up to four CH keys of a single remote control can be stored if only one any CH key of the remote control is stored command 1 5 step by step opening is carried out from two to four CH keys of a single remote control are stored the functions matched with the CH keys are as follows e CH1 command 1 5 step by step opening e CH2 partial opening command it causes the automation to open for about 1 m e CH3 command to switch on off the courtesy light e CH4 stop command equivalent to impulsive command 1 9 Transmitter cancellation keep pressed for 3 s the PRG button on the radio receiver or on the control panel the SIG LED begins to flash to erase all the transmitters from the memory of the radio receiver keep pressed for 3 s again the PRG button to erase a single transmitter press one of the previously stored CH keys of the transmitter to be era
3. Apply hazard area notices required by applicable regulations Each installation must clearly show the identification details of the motorized door When necessary connect the motorized door to a reliable earth system made in accordance with applicable safety regulations During installation maintenance and repair interrupt the power supply before opening the lid to access the electrical parts The protective casing of the automation must be removed by qualified personnel only To handle electronic parts wear earthed antistatic conductive bracelets The motor manufacturer declines all responsibility A in the event of component parts being fitted that are not compatible with the safe an correct operation Forrepairs or replacements of products only original spare parts must be used The installer shall provide all information relating to automatic manual and emergency operation of the motorized door and provide the user with operating instructions 1 1 Installation warning Secure the control panel permanently Drill a hole into the lower side of the container so as to run the cables through it Secure the cables if they are accessible by means of appropriate gland plates not provided by us Keep the line and motor conductors separate at least 8 mm from the control conductors at the terminal board connection points for example by means of clamps Connect the line and motor protection conductors yellow green by means of the transformer and cont
4. OFF b gt 4 6 4 aie MAX x JR6 m Limit switch Limit switch Opening Closing J12 B eec OUT1 in PT3 MAX 12 0 11 000 JR6 m 1211 0 1 5 6 8 9 41 B Opening Closing Limit switch Limit switch IP2045EN 2013 03 26 IP2045EN 2013 03 26 All rights related to this material are the exclusive property of Entrematic Group AB Although the contents of this publication have been compiled with the greatest possible care Entrematic Group AB cannot accept liability for any damage that might arise from errors or omissions in this publication We reserve the right to make modifications without prior notice No part of this publication may be copied scanned adapted or modified without prior permission in writing from Entrematic Group AB 15 IP2045EN 2013 03 26 Entrematic Italy S p A Via Mons Banfi 3 e 21042 Caronno P lla VA Italy Tel 39 02 963911 Fax 39 02 9650314 www ditecentrematic com ENTRE MATIC
5. 41 8 are open any operation the opening operation is impossible NOTE after the activation of the proximity limit switch closes the opening of the safety contact 1 8 41 8 provokes the STOP during the closing phase Closing Stop Flashing e e e e e Safety test failure terminal 41 Operations count performed only when control panel is switched on 1000 operations emu 10000 operations Activated at every command and adjustment to the dip switch and jumper Indicates that the 0 11 limit switch contact is open Indicates that the 0 12 limit switch contact is open Activated during the radio reception phase or transmitter me Indicates the absence of the memory module morisation 7 Radio Receiver The control panel is equipped with a radio receiver with a frequency of 433 92 MHz The antenna consists of a rigid wire 173 mm long connected to the ANT clamp It is possible to increase the range of the radio by connecting the antenna of the flashing lights or by installing the tuned BIXAL antenna NOTE to connect the external antenna to the control panel use a coaxial cable type RG58 max 10 m Check that the storage module is inserted on COM connector of the control panel Up to 200 remote controls can be stored in the storage module WARNING if the radio receiver on the control panel is not used set JR3 OFF and remove the storage module Transmitter storage
6. D tec ENTRE MATIC IP2045EN Ditec E1A Exp ex e sl er m e lo C SIC m 0 M 12 34 159 Q Jes dois Buiuedoau Ajajes ooi ep Jes dois days Aq deis jndino s lioss 55v YOUMS puq YOUMS puq E 5 E 9 5 9 0 10 N3S70 dl IP2045EN 2013 03 26 Index Subject Page General safety precautions 4 2 EC declaration of conformity 5 3k Technical data 5 3 1 Applications 5 4 Commands 6 4 1 Self controlled safety edge 6 5 Outputs and accessories 7 6 Adjustments 8 6 1 Trimmer 8 6 2 Dip switch 8 6 3 Jumper 9 6 4 Signals 9 7 Radio 10 8 Start up 11 oF Troubleshooting 11 10 Application example for sliding doors and gates 12 11 Application example for in parallel automations 12 12 Application example for barriers 13 13 Application example for rolling shutters 13 14 Application example for sectional overhead doors 14 Caption A This symbol indicates instructions or notes regarding safety issues which require particular attention EB this symbol indicates informations which are useful for correct product function 2 1 General safety precautions This installation manual is intended for qualified personnel only Installation electrical connections and adjustm
7. NCY STOP X OLD TO RUN UNCTION 7 CLOSING LIMIT SWITCH CLOSING PROXIMITY SWITCH OPENING LIMIT SWITCH OPENING PROXIMITY SWITCH Description With DIP1 OFF and TC MAX the closure of the contact activates an opening or closing operation in the following sequence open stop close open NOTE the stop is not permanent but has the duration set by TC With DIP1 OFF and TC MAxX the closure of the contact activates an opening or closing operation in the following sequence open stop close open With DIP1 ON and TC MAX the closure of the contact activates an opening operation With DIP1 ON and TC MAX the closure of the contact activates an opening operation If 6 gt 4 0N with the automation idle contact 1 5 performs the closure operation as well If 64 OFF the closure operation is performed by contact 1 6 With 6 4 OFF the closure of the contact activates a closing operation The opening of the safety contact stops and prevents any movement Opening the safety contact triggers a reversal of the movement reopening during a closing operation Opening the safety contact stops the current operation To enable the emergency stop function e g with a specific red button connect the opening and closing controls to terminal 9 instead of 1 9 5 9 6 Permanently opening the safety contact enables the operator presence dependent function In this state the opening 1 5 and closing 1 6 controls function only
8. afety edge SOFA1 SOFA2 or GOPAVRS Command ooo 1 6 1 t 8 SOFA1 SOFA2 GOPAV Lv y 000 N C N C Function SAFEIYMESI STOP SAFETY DEVICE REVERSAL SAFETY DEVICE Description Place the SOFA1 SOFA2 or GOPAVRS device into its housing for plug in cards AUX Connecting terminal 41 enables a safety edge test cycle before every operation If the test fails the SA led flashes and the test is repeated Connect the output contact of device SOFA1 SOFA2 to terminals 1 6 on the control panel in series with the photocell output contact if installed Connect the output contact of device SOFA1 SOFA2 to terminals 1 8 on the control panel in series with the photocell output contact if installed ATTENTION for quick operation on the safety edge connect it to contact 1 6 IP2045EN 2013 03 26 IP2045EN 2013 03 26 9 Output and accessories Output LB 01 AUX HOO UW V Jl2 eee Value Accessories 24 V 0 5 A SOFA1 SOFA2 GOPAV 24 V 3 W QIKLUX 24 V 120 mA max 24 Vx 3 W QIKLUX 24 V 120 mA max 230V 5A 120 V ETAJ LAMP 230 V 25 W 120 V E1AJ LUXK7 230 V 60 W 120 V E1AJ 230 V 100 W 120 V E1AJ 4 o Description Accessories power supply Power supply output for externa
9. ents must be performed in accordance with Good Working Methods and in compliance with applicable regulations Before installing the product carefully read the instructions Bad installation could be hazardous e The packaging materials plastic polystyrene etc should not be discarded in the environment or left within reach of children as these are a potential source of hazard Before installing the product make sure it is in perfect condition Do not install the product in an explosive environment and atmosphere gas or inflammable fumes are a serious hazard risk Before installing the motors make all structural changes relating to safety clearances and protection or segregation of all areas where there is risk of being crushed cut or dragged and danger areas in general ake sure the existing structure is up to standard in terms of strength and stability The motor manufacturer is not responsible or failure to use Good Working Methods in building the frames to be motorized or for any deformation occurring during use The safety devices photocells safety edges emergency stops etc must be installed taking into account applicable laws and directives Good Working Methods installation premises system operating logic and the forces developed by the motorized door The safety devices must protect any areas where the risk exists of being crushed cut or gragged or where there are any other risks generated by the motorized door
10. hat allows the automation to function correctly while ensuring the safety of the user in the event of collision e Set obstacle thrust with R1 NOTE ensure that the forces exerted by the door wings are compliant with EN12453 EN12445 regulations Connect any other accessories and check operation Once the start up and check procedures are completed close the container 9 Troubleshooting Problem Possible causes Remedy Automation does not open or close No power Check that the control panel is powered cor POWER led off rectly Short circuited accessories Disconnect all accessories from terminals 0 1 POWER led off voltage must be 24 V and reconnect one at a time Blown line fuse POWER led off Replace fuse Safety contacts are open Check that the safety contacts are closed cor SA led on rectly N C Safety contacts not correctly connected or Check connections to terminals 6 8 on control self controlled safety edge SOFA1 SOFA2 not panel and connections to the self controlled functioning correctly SA led flashing safety edge SOFA1 SOFA2 Release microswitch open Check that the hatch is closed correctly and the 11 and 12 led on microswitch makes contact The motor thermal overload switch is open Check for continuity between the phases U V W of the motor disconnected from the control panel The remote control does not work Check the correct memorisation of the transmit ters on the inc
11. ic closing is obtained by regulating the TC trimmer not at the maximum and in the same position in both control panels n T TI SWT wo automations A i TC TM JR3 rmm ld Ol WL Th ee Nd XVI R1 st o ire N E o oo o jon INS MAX MEI m m gt gt m gt IP2045EN 2013 03 26 IP2045EN 2013 03 2 12 Example application for barriers When control panel is used for barriers operations set RF 5 MAX set M MAX set JR6 ON select the proper opening direction by means of DIP2 DIP2 0FF Example 1 Connect opening and closing limit switches N C contacts to plug 12 0 11 J Huu DIP2 0N m Example 2 Control N C 1 6 safety stop can be changed into control N O 1 4 closing setting 64 0FF To have the barrier close again soon after transit between the photocells or other safeties connected to 1 8 set DIP3 OFF 13 Application example for rolling shutters Qe MAX TC TM 12 0 11 Limit switch JR6 1211 0 1 5 8 9 41 BHH H
12. if held in the pressed position and the automation stops when the controls are released Any safety devices plus the autornatic closing are disactivated With DIP2 OFF the opening of the contact blocks the movement of the automation during the closing phase With DIP2 ON the opening of the contact blocks the movement of the automation during the opening phase Alternatively you can connect the limit switch to the fastons 0 11 in this case the terminals 0 11 must not be jumped In the event of obstacle detection during closing and before the activation of the proximity limit switch the door wing reopens after the activation of the proximity limit switch the door wing blocks against the mechanical closing stop With DIP2 OFF the opening of the contact blocks the movement of the automation during the opening phase With DIP2 ON the opening of the contact blocks the movement of the automation during the closing phase Alternatively you can connect the limit switch to the fastons 0 12 in this case the terminals 0 12 must not be jumped In the event of obstacle detection before the activation of the proximity limit switch while opening the door wing stops performing a disengagement operation after the activation of the proximity limit switch the door wing blocks against the mechanical opening stop AA WARNING Make a jumper on all N C contacts if notin use The terminals with the same number are equal 4 1 Self controlled s
13. l accessories including automation status lamps The control panel has one space for coupling board type radio receivers magnetic loops etc The coupling board working mode is selected by DIP1 WARNING the plug in cards must be inserted and removed with the power supply disconnected Automation open lamp Only with the limit switch 0 11 N C connected and DIP2 0FF will the light switch off when the automation is closed Automation closed lamp With DIP2 ON the light switches off when the automation is open Light kit for QIK barrier With DIP2 ON the light switches off when the automation is open Automation closed lamp Only with the limit switch 0 12 N C connected and DIP2 OFF will the light switch off when the automation is open Automation open lamp With DIP2 ON the light switches off when the automation is closed Light kit for GIK barrier With DIP2 OFF the light switches off when the automation is open Motor 1 M1 Terminal W must be connected to the common motor phase connection The condenser must be connected between the U and V phases Flashing light Activated during opening and closing operations Courtesy light in CROSS sliding automation Comes on for 180 seconds after receiving any opening total or partial or closing command LAN WARNING use a double insulated cable Drive unit external courtesy light Comes on for 180 seconds after receiving any opening total or partial or closi
14. minial entrances Closed The first command 1 5 activates the ope ning NOTE the automatic closing will not be the first command even if enabled If the automatic closing function is not used preferably set DIP4 ON IP2045EN 2013 03 26 IP2045EN 2013 03 26 6 3 Jumper Jumper JR3 JR4 JR6 JR10 NIO so 634 Description Incorporated radio receiver Overtravel reduction Reduces the overtravel distance for the door wing Application type Maximum power start Electronic antifreeze system Maintains motor function even at low am bient temperatures NOTE for correct operation the control panel must be exposed to the same am bient temperature as the motors Reversal safety switch function Control 1 6 function 6 4 Signals LED POWER m SA mm 117 m 12 SIG On 24 V power supply Indicates that at least one of the safety contacts is open OFF j ON Disabled Enabled Disabled Enabled OTE preferably set JR4 ON if the door wing performs an excessive overtravel Sliding gate Other applications Disabled Enabled The motor starts with the voltage set with The motor starts at maximum power for 1 s RF Enabled ATTENTION do not use with E1AJ Disabled With the automation blocked if the contacts With the automation blocked if the con 1 8 or 41 8 are open itis possible to activate tacts 1 8 or
15. ng command JAN WARNING use a double insulated cable Membrane push button panel PT3 Starts the opening operation NOTE to activate the closing operation connect the connector of the push button panel to J12 rotated by 180 Membrane push button panel PT3 Causes the blocking of the movement Membrane push button panel PT3 Starts the closing operation NOTE to activate the opening operation connect the connector of the push button panel to J12 rotated by 180 E1A E1AJ 6 Adjustments 6 1 Trimmer The control panel is equipped with a safety system that stops motion if an obstacle is encountered during an opening operation and either stops or reverses motion during a closing operation R1 MIN gives maximum obstacle sensitivity minimum thrust Trimmer Description R1 Setting obstacle thrust MIN 0M R1 MAX disables detection maximum thrust TC Setting automatic closing time a 120s MIN 0 s 4 MAX disabled From 0 to 120 s With TC MAX the automatic closing is disactivated The count begins from the blocking of the automation for the time set by the TC With DIP3 OFF once a safety switch has been activated the counter starts as soon as the safety switch is released for example after passing through the photocells and lasts for a period of time set with TC 5096 No
16. orporated radio The remote control does not work Memory module BIXMR2 absent SIG led flashing Automation opens but does not close Safety contacts are open Check that the safety contacts are closed cor SA led on rectly N C Safety contacts not correctly connected or Check connections to terminals 6 8 on control self controlled safety edge SOFA1 SOFA2 not panel and connections to the self controlled functioning correctly safety edge SOFA1 SOFA2 SA led flashing Photocells activated Check that the photocells are clean and oper SA led on ating correctly The automatic closing does not work Check that the TC trimmer is not set at the maximum The automation is very weak and does not invert The motor s condenser has an incorrect capac Replace the motor s condenser the movement ity value External safety devices not activating Incorrect connections between the photocells Connect NC safety devices together in series and the control panel and remove any bridges on the control panel terminal board The remote control has limited range and does The radio transmission is impeded by metal Install the antenna outside Substitute the not work with the automation moving structures and reinforced concrete walls transmitter batteries 11 10 Example applications for sliding door and gates When control panel is used for sliding automations operations ma ee select the p
17. rol panel using the clamp provided At the end of the installation to close again the container IP2045EN 2013 03 26 IP2045EN 2013 03 2 2 EC Declaration of conformity The manufacturer Entrematic Group AB with headquarters in Lodjursgatan 10 SE 261 44 Landskrona Sweden declares that the control panel Ditec E1A is in conformity with the provisions of the following EC directives EMC Directive 2004 108 CE Low energy Directive 2006 95 CE R amp TTE Directive 1999 5 CE Landskrona 29 01 2013 Marco Pietro Zini 24BA Pr sident 3 Technical data E1A E1AJ Power supply 230 V 50 Hz 120 V 60 Hz F6 3A Fuse F1 F8A with NIO 0FF FRE Fuse F2 F6 3A Motor output 230 V 5A max 120 V 6 3A max Accessories power supply 24 V 0 5A 24 V 0 5 A Temperature min 20 C max 55 C min 20 C max 55 C Degree of protection IP55 IP55 Radio frequency 433 92 MHz 433 92 MHz Memorizable radio codes 200 200 m 3 Applications III 4 Commands Command 1 F 1 7 6 1 9 0 gt gt 1 0 11 0 t_ 12 0 12 AEOS N O N C N C N O N C N O Function STEP BY STEP WITH AUTOMATIC CLOSING STEP BY STEP WITHOUT AUTOMATIC CLOSING OPENING WITH AUTOMATIC CLOSING OPENING WITHOUT AUTOMATIC CLOSING CLOSING SAFETY STOP REVERSAL SAFETY DEVICE S E TOP MERGE
18. roper opening direction by means of DIP2 DIP2 0FF Example 1 Connect opening and closing limit switches N C contacts MAX to plug 12 0 11 or Example 2 Connect opening and closing limit switches N C contacts to terminals 0 11 12 With the above connections when limit switches operate the wing stops In the event of obstacle detection the wing stops and releases during opening operation and reopens during closing operation o Eo ines R1 TC TM 12 0 11 JR6 rem DIP2 0N li DIP2 0FF v lt MAX MAX aal fuos ells R1 TC TM 12 0 11 JR DIP2 0N hn Limit switch Limit switch 11 Example of automation in parallel haul BIXLR22 c JR2 m FEE It is possible to command and B side by side making the connections indicated in figure Commands 1 5 and the remote control with DIP1 ON are equivalent to a total opening com mand To manage both automations with a single re mote control do not use the radio receivers on the control panels but insert a BIXLR22 receiver The automat
19. sed the cancellation is confirmed by the quick flashing of the SIG LED If the control panel is replaced the storage module being used can be inserted in the new control panel IP2045EN 2013 03 26 IP2045EN 2013 03 2 8 Starting e Bridge the NC safety contacts with a jumper Before starting up check the application type selected see JR jumper Any limit switches installed must be adjusted so that they are triggered near the mechanical opening and closing end stops Set TM MAX NOTE limit switches must be kept pressed until the operation has been completed f no limit switches are installed bridge terminals 0 11 and 0 12 with jumpers and set TM to half e Set TC MAX Set RF and R1 to half Using DIP2 set the direction Switch on power JAN WARNING The following operations are performed with no safety devices 2 e Perform opening and closing commands and check that the automation functions correctly and that the limit switches if instal led are correctly set NOTE if mechanical stops are used to block the stroke of the automation or a proximity limit switch with N O contact adjust the TM trimmer in order to obtain an operation time 2 3 s greater than the time effectively taken by the automation Connect the safety devices removing the relative jumpers and check that they function correctly f required regulate the automatic closing by means of the TC trimmer Set RF to a position t
20. te with DIP3 OFF and 64 0FF the automatic closing is immediate With DIP3 ON the counter starts when automation is opened and lasts for the entire duration set with TC 100 NOTE after the activation of the stop command once contact 1 9 has closed again the automatic closing is only activated after a total or step by step opening command TM Setting the operating time 60s From 10 to 120 s Q NOTE with NC limit switch set TM MAX MIN 10 s MAX 120 s RF Power setting Sets voltage supplied to motor 1 MIN 5 MAX RF Power setting Sets voltage supplied to motor CT 1 MIN CT 5 MAXJ Ch 4 2 o amp 6 2 Dip switch fA ATTENTION disconnect the power supply before adjusting 00 DIP Description DIP1 Control 1 5 function DIP2 Direction selection DIP3 Restore automatic closing time DIP4 Automation status at power on Indicates how the control panel considers automation when powered up OFF Step by Step Opens towards right 50 Immediate if 64 OFF NOTE the setting of DIP3 OFF and 6 4 0FF is recommended for the imme diate reclosing of the barriers Open If DIP1 OFF the first command 1 5 activates the closing If DIP1 ON the first command 1 5 activates the opening NOTE with a limit switch installed prefera bly set DIPA OFF ON f Opening Opens towards left 10096 NOTE the setting of DIP3 ON is recom mended for overhead and sectional doors and condo
Download Pdf Manuals
Related Search
Related Contents
Si Wave バージョン1.xx 取扱説明書 (PDFファイル) OCTO range USER'S MANUAL VILLE DE BRUXELLES STAD BRUSSEL Clique aqui e faça o do PDF Apple 8100/80AV Personal Computer User Manual Fedora8-Xen Installation Guide Eglo NORBELLO ETI_HS_Puder Spray_200ml_QX6-08-07 Sprint Nextel Old Telephone Service User's Manual Copyright © All rights reserved.