1. a failure or malfunctions When installing a CF card into this unit be sure to insert it into the card slot of this unit Before inserting or removing a CF card into from this unit turn the CF card access switch off Failure to do so may corrupt data on the CF card When removing a CF card from the GOT support it by hand as it may pop out Failure to do so may cause the CF card to drop from the unit resulting in a damage or failure Wiring precautions lt amp DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions A CAUTION Carefully prevent foreign matter such as dust or wire chips from entering this unit Failure to do so may cause a fire failure or malfunctions Plug the cable into the connector of the connected unit and tighten the mounting screws If the screw is too loose it may cause a short circuit or malfunctions If too tight it may damage the screw and or the unit resulting in a short circuit or malfunctions Startup and maintenance precautions lt amp DANGER Be sure to shut off all phases of the external power supply of the GOT main unit before starting cleaning Not doing so can cause the unit to fail or malfunction A CAUTION Do not disassemble or modify this unit and CF card Doing so can cause failure malfunctions personal injuries and
2. card unit and a CF card extension unit The CF card unit and the CF card extension unit cannot be used at once When using the CF card extension unit the control panel side installation unit on the control panel has the CF card interface Therefore when inserting or ejecting the CF card there is no need to open the control panel s door CF card extension unit When using the CF card extension unit set the Communication Settings For setting refer to GT15 User s Manual 2 Specifications The following table shows the performance specifications of the CF card extension unit The general specifications of the CF card extension unit are the same as those of the GOT For the general specifications of the GOT refer to GT15 User s Manual Item Specifications Internal current consumption 5VDC Oma lot ESTEER CF card Outside cover closed Protective the enclosure CF card structure cover opened IP2X IP67 or IP65 Inside the enclosure IP2X Weight 0 47kg 1 03Ib When changing the dustproof rubber to the CF card cover fixing screw the specification for the protective structure is IP67 3 Part Names and External Dimensions 4 Installation Procedure 1 GOT side installation unit 63 2 48 Kelke go 9 5 fe o 9 62 5 2 46 lt E Js 2 36 Unit mm inch No Nam
3. inch 2 Fix the GOT side installation unit by tightening its fixing screws 2 places with a tightening torque of 0 36 to 0 48N m 3 Insert the connector with the ground cable into the GOT side installation unit and insert the connector without the ground cable into the control panel side installation unit For GT1550 before connecting the connection cable to the GOT side installation unit connect the ground cable of the connection cable to the GOT s terminal block Because the GOT s terminal block overlaps with the connection cable the ground cable cannot be connected to the GOT s terminal block After inserting the connectors tighten the connection cable fixing screws GOT side installation unit Control panel side installation unit Ground cable 4 Install the shorting bar to the LG and FG terminals of the GOT s power Connect the ground cable of the connection cable with the GOT s ground cable to the FG terminal of the GOT s power For GT1550 connect the ground cable of the connection cable to the FG terminal of the GOT s power and connect the GOT s ground cable to the protective ground terminal Shorting is not needed When connecting the ground cables each flat side of the two solderless terminals must be faced For the details of wiring refer to GT15 User s Manual L NLGFG LNLG FG Ground cable Terminal Solderless SS RK of connection screw terminal J
4. NFOR SAFE USE This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 l 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cu
5. Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 aMITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry lof Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan on recycled paper
6. the equipment inside the control panel including the cables of extension units and the CF card interface of the GOT Keep the distance of 25mm 0 98 inch or more between the control panel side installation unit and the GOT For the installation location refer to GT15 User s Manual 2 Extension units cannot be installed on the GOT side installation unit When installing other extension units install the GOT side installation unit at the last 3 When removing the GOT side installation unit tilt A PULL of the unit and remove the unit so as not to break the connector 5 CF Card Installation Removal Procedure 5 1 Installation 1 Open the CF card cover and turn off the CF card access switch of the unit 2 Insert the CF card into the CF card connector with the front side facing up L 3 Turn on the CF card access switch 5 2 Removal 1 Open the CF card cover Turn off the CF card access switch and check that the CF card access LED turns off The CF card can be removed when the CF card access LED turns off even though the GOT s power is on WARRANTY Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties
7. MITSUBISHI GT15 CF Card extension unit User s Manual GT15 CFEX CO8SET _ _ Set of GT15 CFEX GT15 CFEXIF and GT15 C08CF Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 CFEX CO8SET U MODEL CODE IB NA 0800367 B 0707 MEE 1D7M64 GRAPHIC OPERATION TERMINAL GOTIO SAFETY PRECAUTIONS Be sure to read these instructions before use Before using this product read this and relevant manuals carefully and handle the product correctly with full attention to safety Note that these precautions apply only to this product In this manual SAFETY PRECAUTIONS are classified into 2 levels DANGER and CAUTION e I ndicates that incorrect handling may cause I gt DANGER hazardous conditions resulting in death or 4 I severe injury I I I I ndicates that incorrect handling may cause I I A CAUTION hazardous conditions resulting in medium or l X slight personal injury or physical damage j Under some circumstances failure to observe the CAUTION level instructions may also lead to serious accidents Be sure to observe the instructions of both levels to ensure the safety Please keep this manual in a safe place for future reference and also pass this manual on to the end user D
8. cable at Ground Shorting Shorting bar cable of GOT bar For the ground cable of the connection cable use the following solderless terminals Applicable solderless terminal RAV1 25 3 V1 25 B3A FV1 25 B3A 4 3 Installing CF Card Cover Fixing Screw The protective structure of the outside the enclosure for the control panel side installation unit is IP65 in shipping For IP67 of the protective structure follow the procedure below 1 Open the CF card cover and remove the dustproof rubber in the direction of the arrow 2 Insert the CF card cover fixing screw into the hole of the CF card cover and install the washer in the direction of the arrows 3 Close the CF card cover and tighten the CF card cover fixing 4 4 Installation and Removal Precautions 1 When installing the CF card extension unit make space of the dimensions shown in the following figures inside the control panel The bending radius of the cable must be the value shown in the following figures 18to23 100 3 94 0 71 to 0 91 or more GOT side ARO Control panel side 180 7 09 or more installation unit installation unit Other equipmemt GOT Uj olf R Bending radius of the R Bending radius U ANT cable 55 2 17 or more of the cable 55 2 17 or more The dimension differs depending on the GOT Unit mm inch When installing the control panel side installation unit on the control panel install the unit out of the way for
9. e Description LED lamp lit when the CF card is accessed 1 CF card access LED Switch for disabling the access to the CF card access CF card switch ON Access to the CF card enabled OFF Access to the CF card disabled Button for removing the CF card 2 3 Eject button Cover opening closing at CF card 2 Clacardicover installation removal Cable connector for connecting the GOT side installation unit and the control panel side installation unit 6 CF card connector Connector for installing the CF card 7 Rating plate 5 Cable connector 8 Fixing screw for GOT Fixing screw fixed with a front extension side installation unit unit or the GOT Hole for unit installation fitting Hole for the fitting installing the unit to the control panel Rubber for blocking the CF card cover fixing screw hole 9 10 Dustproof rubber 4 1 Installing on GOT 1 Power off the GOT 2 Remove one of extension unit cover of the GOT and fit the GOT side installation unit in the GOT case 3 Fix the GOT side installation unit by tightening its fixing screws 2 places with a tightening torque of 0 36 to 0 48Nem 4 2 Installing on the control panel 1 Insert the control panel side 947 3 700 installation unit into the installation oo hole of the control panel ee For the installation hole refer to the oF 209 R figure right m Unit mm 4 J
10. esign precautions A CAUTION Do not install the control lines or communication cables together with the main circuit or power lines or bring them close to each other Keep a distance of 100mm 3 9inch or more between them Failure to do so may cause malfunctions due to noise Installation precautions lt amp DANGER Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause the unit to fail or malfunction When installing this unit wear a wrist strap to prevent the unit from being damaged by static electricity Be sure to shut off all phases of the external power supply of the GOT main unit before connecting the cable to this unit Not doing so can cause the unit to fail or malfunction A CAUTION Use this unit under the environment specified in the GT15 User s Manual Otherwise it may cause electric shocks fires malfunctions product deterioration or damage When installing the GOT side installation unit fit it to the connection interface of the GOT and tighten the mounting screws When installing the control panel side installation unit install it on the control panel and tighten the screws of the installation fittings If the screw is too loose it may cause a drop of the unit a failure or malfunctions Tightening the screw excessively may damage the screw and or the unit resulting in a drop of the unit
11. gat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M 1 D C Bhosari
12. ode SH 080528 Sold separately 1D7M23 Manual name GT15 User s Manual Relevant Manuals For relevant manuals refer to the PDF manuals stored with the drawing software used 2006 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives refer to EMC Directives and Low Voltage Directives of the manual GT15 General Description included with the GOT used The CE logo is printed on the rating plate of the GOT indicating compliance with the EMC and low voltage directives Packing List The following items are included Model Product Quantity Control panel side 1 installation unit GT15 CFEX installation fitting 2 GT15 CF card cover fixing screw il CFEX GOT side installation unit 1 CO8SET Fixing screw for GOT side GT15 CFEXIF ingtailation unit 2 Shorting bar 1 GT15 CO8CF Connection cable 0 8m 1 1 Overview This User s Manual describes the GT15 CF card extension unit hereinafter abbreviated as CF card extension unit For GOT to which the units can be installed and usable CF cards refer to GT15 User s Manual When using an additional drive the CF card extension unit can be used as the B drive of the GOT The extension units used as the B drive of the GOT are a CF
13. or a fire Do not touch the conductive and electronic parts of this unit directly Doing so can cause a unit malfunction or failure The cable connected to this unit must be run in a duct or clamped Not doing so can cause the unit or cable to be damaged due to the dangling motion or accidental pulling of the cable or can cause a malfunction due to a cable connection fault When unplugging the cable connected to this unit do not hold and pull the cable portion Doing so can cause the unit or cable to be damaged or can cause a malfunction due to a cable connection fault Do not drop or apply strong impact to this unit or the CF card Doing so may damage the unit or CF card Before handling this unit touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause failure or malfunctions of the unit Disposal precautions A CAUTION When disposing of the product treat it as an industrial waste Transportation precautions A CAUTION Make sure to transport this unit in the manner it will not be exposed to the impact exceeding the impact resistance described in the general specifications of GT15 User s Manual as it is a precision device Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation MANUALS The following shows manuals relevant to this product Detailed Manual Manual number Model c
Download Pdf Manuals
Related Search
Related Contents
「総監択一問題ヒストグラム」 Téléphone SIP Forum IPhone 545 Home Decorators Collection 0463530960 Instructions / Assembly Arrow Sheds MANUAL DE OPERACION AUTUCLAVE ALL AMERICAN Honeywell FSW-505E ¿Qué es el Programa Canadiense de Arbitraje para AST-CB1203PIR - Radio Matériel OWC Express document - La vie protestante Neuchâtel Copyright © All rights reserved.