Home
        Model No.: HCA-P12HP-A Reference No.: APA12HP
         Contents
1.            Compressor Indicator     amp         Th icon will light up on the control panel display when the compressor turns on  The   9  icon will    turn off when the compressor shuts off     Emergency Condensate Holding Tank    When the room temperature is low and the indoor humidity is high  the air conditioner may not be able to     evaporate some of the moisture fast enough  When this happens  the water will accumulate in an emergency  condensate tank inside the unit  When the condensate tank is full  the unit will display    FULL    on the control  panel  To empty the condensate tank  unscrew the screw plug at the bottom back of the unit  You will need a  small pan  approximately 1    high to catch the water coming out of the condensate tank  Once the condensate  tank is drained  the unit will begin working within a few minutes  The emergency condensate tank holds        proximately 1 5 Liters of water  Another option is to purchase a small hose from a hardware store that can fit  around the 5 8    drain plug on the back of the unit and drain the unit into a gravity drain or larger pan for con   tinuous drainage         resume operation quickly  empty the water container according to the following steps      Tum the unit off  Do not move the unit when the water container is full     Place the drain pan accessory under the drainage port at the back of the unit    Remove the drain plug from the drain hole  The condensate water will drain out automatically  When the  drai
2.      7  Do not use the unit       n the immediate surroundings of a bath  a shower or a sw        nming pool        Do not insert anything into the air outlet  Do not obstruct air inlet or outlet grills unless instructed by this manual   9  Do not let children play near this unit     10  Always inspect the cord for signs of damage before use  If the power cord is damaged  it must be replaced by the    manufacturer or a qualified service technician   11  When cleaning the unit  always tum the unit off and unplug the power cord  12  When the unit is not in use  always remove the venting kit ftom window  13  Do Not Mix Old And New Batteries   Do Not Mix Alkaline  Standard  Carbon   Zinc   Or Rechargeable  Nickel   Cadmium  Batteries     14  Wh          hanging between heating and cooling mode there will be a 3 5 minute delay for the compressor to start   During this time  the refrigerant inside the portable air conditioner will return to the compressor to start heating or    cooling your area            PACKAGE CONTENTS    Portable Air Conditioner  Exhaust Hose  1    Hose Adapters  1    Window Kit Adapter  1    Remote Control   AAA Batteries  2    Window Kit   2 Sliding Panels  1 single hose panel    extension panels   Owner s Manual       TEES     SPECIFICATIONS      The cooling capacity is measured at an ambient temperature of DB 86   F  WB 78   F    Noise level is measured at a distance of 3 28 ft away from the front of the unit  when the unit is in cooling mode           Pow
3.     Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Home  Comfort     Freight and Insurance cost for the warranty service     ALL WARRANTIES  INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO  ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY  SOLEUS HOME COMFORT  DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT  SHALL SOLEUS  S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR  BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT              This warranty covers only new products purchased from our authorized dealers or retailers  It does not cover used  sal   vaged  or refurbished products     As some states do not allow the limitation or exclusion of incidental or consequential damages  or do not allow  limitation on implied warranties  the above limitations and exclusions may not apply to you  This warranty gives you  specific legal rights  and you may also have other rights that vary from state to state           
4.   Heat Mode  F  Fan Speed  Low  High  Me   dium   G  Temperature      Swing Mode     1  Sleep Mode         J  Clock and Timer   or   AM   O h k      Timer On UUI        DO       oo   L  Timer Off        Compressor is on                  OPERATING INSTRUCTIONS     CONTROL PANEL BUTTONS  Refer to the images on page 9   1  Power On and Off   Press the POWER button once to manually turn the unit on  Press the POWER  button once more to turn the unit off    2  Mode Selection   Press the MODE Button repeatedly to cycle between the different modes  Auto mode          Conditioner  Heater  Dehumidifier  and Fan        3  Fan Speed Control   Press the FAN SPEED Button to cycle through the different fan speeds  High   Medium  and low  The fan speed can be visually distinguished by the speed of the digital air segments  progressing out from the windmill fan image on the Multi color display    4  Temperature   Select the desired temperature by pressing either    or    button when using the unit in  cool or heat mode  The temperature indicator flashes to display the desired temperature setting  After the  temperature is set  the unit will display this temperature setting until it is changed by the user  The Multi   color display shows temperature in Celsius or Fahrenheit  Press the    or    buttons simultaneously on the  control panel to select the desired temperature setting     5  Timer   To program the timer  press the TIMER ON button until the display shows a flashing           Press t
5.   eB       ee   pore     Open the window or siding door and aust he      length ofthe window K   to ft the opening  Ifthe                                        window kts not long enough  connect      xtra                window kt panel to ithe opening  Mark and cut a            single panel of the window kitit neces                 Maximum  55               Place the window      between the window and the   window fame as shown in the images to he right   Close the window onto the window Kit to fom a VERTICAL             tight sea             Atach the exhaust duct adapter to the window kt  Tabs located on the adapter wil lock into place  securing the adapter to the window K       m     Window siider Kit  Minimum  28 5            Maximum  55                                                   WINDOW KIT INSTALLATION  cont d            Installation of the Venting Kit           oat  FOR SINGLE HOSE PORTABLE AIR CONDITIONERS     The venting kit must be installed in order forthe unit to  work              in the air conditioning mode  The wanting  Kit should not be used while the unit is beating or  fanning    The window kit has been designed to fit into most vertical         horizontal window openings  The window hit cen also  be used      sliding doar     1  Choose a suitable location  noar a grounded electrical  outlet and a suitable window or door  Remove  packaging and locate components   figure a        Gude the                senneeter evor the diesharse      opening on th
6.  Control panel   B  Vertical air louvers  C  Air ouet   D  Horizontal air louvers  E Casters   F  Power Gord  amp  Plug    BACK    A Hotair outet gril  B  Lower      gril    ACCESSORIES           exhaust hose wih 2 adapters     3piece set     strotches from 14 114 to 60 5 8             150cm     Adjustable window slider kit     piece set     adjusts 28 50 55     Drain tube    Drain pan                                            22 Drain Pi  Drain Tube K Pre Pan    Exhaust Hose Window Exhaust Adapter                                   oN Adjustable Window Slider Kit    Adapter       3    La  INSTALLATION    SELECTING THE LOCATION           the uni in a fat locaton where the air out   lets are not obstructed  Place the unit at least  207  0em                  a wa or other obstacle        MOUNTING THE EXHAUST HOSE     Sle he square end of the exhaust duct over the  hot air outlet onthe back ol he unt        Te exhaust hose should be kept as short and  straight as possible  Prevent any sharp bends in EY    EN    Hot Air Outlet             The hot exhaust air can be vented through the  wall or out a window  f mounting in the wall  he  height at he hole shouid be 16 to 50 inches         130em      Soleus Air does not provide a venting kit for  through the wal ventilation  Venting through he  wali requires a custom instalation                                                                       WINDOW KIT INSTALLATION    WINDOW KIT INSTALLATION HORIZONTAL WINDOW     E              
7.  cord and plug will remove the supply source via electrical disconnect  circuit trip  if the  nominal current leakage between the cord shield and either load conductor exceeds a predetermined value   The cord will remain de energized until the devise has been manually reset  This is intended to reduce the risk  of a fire in the power cord or combustible materials nearby  The cord shields are not grounded and they must  be considered a shock hazards if exposed  The cord shield must not be connected to ground or to any exposed  metal           The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly  To test   1  Plug power cord into wall outlet  2  Press TEST Button  circuit should trip  cutting power to the air conditioner  3  Press RESET button for use   If test button is pressed and unit can still be turned on  current leakage has been detected  Do not use the air    conditioner or attempt to reset the LCDI Plug  Contact Soleus Air Customer Service for troubleshooting  recommendations     RESET    TEST       WARNING     DO NOT press the TEST button while the air conditioner is operating           The TEST and RESET buttons should not be used as    ON    and    OFF    switches   3  The cord and plug are not intended to offer protection to externally connected loads or supply circuits   4  The cord and plug are intended for indoor use only        PRODUCT DIAGRAM  Actual product design may differ slightly from images below     FRONT  A 
8.  gt     Portable Air Conditioner and Heater  With Heat Pump Technology  Operating Instructions       Model No   HCA P12HP A  Reference No   APA12HP          Thank you for choosing a Soleus Air Portable Air Conditioner  This owner s manual will provide you  with valuable information necessary for the proper care and maintenance of your new product  Please  take a few moments to thoroughly read the instructions and familiarize yourself with all the opera   tional aspects of your new Soleus Air Portable Air Conditioner with Heat Pump technology     For your own records  please attach a copy of your sales receipt to this manual  Also  write the store  name location  date purchased  and serial number below     Store Name        Location        Date Purchased           ial Number  located on back of unit      Ss                IMPORTANT INSTRUCTIONS       Before installing and using your portable air conditioner  please read this owner s manual carefully   ual in a safe place for future reference           1  Always place the unit on a level surface   2  Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual    3  Maintain at least 10 inches  25 cm  clearance space around this unit  Do not block or cover      inlet or outlet grilles   4  The unit must be connected to a correctly grounded power supply   5  Do not start or stop the unit by inserting or pulling out the power plug    6  Do not use an adapter plug or extension cord
9.  vented outside  using the supplied window kit        Auto Mode    1  Install the exhaust hose and window kit properly  see pages 7  amp  8     2  Plug the Power Cord into an electrical outlet   3  Tum on the unit by pressing the POWER button on the control panel    4  Press the MODE button        the     5  7 icon appears on the control panel display  Select the fan speed  by pressing the FAN button        NOTE  During AUTO mode  the unit operates in Heating mode when the room temperature is below 68      Dehumidifier mode when the room temperature is between 68   F to 80  F  And Air Conditioner mode when  the room temperature is above 80 F     Sleep Mode  This mode can only be selected when using the Remote control      1  To set Sleep mode  make sure the unit is in Air Conditioner mode   2  Pres he SURE        on thermo co  ito  The      oon appear on      ct panal                      When in SLEEP mode  the fan will run on low to keep fan noise at a minimum  _   4  When in Air Conditioner mode  the temperature setting will gradually increase to 2  F above the origi  temperature for 6 hours  After 6 hours the temperature setting will return to the set temperature    5  When in Heating mode  the temperature setting will gradually decrease to 2  F below the original set tem   perature for 6 hours  After 6 hours  the temperature setting will return to the set temperature    6  When in Dehumidifier mode  the temperature will not change when Sleep mode is selected     il set  
10. L        ir Condi       Mode    1  Install the exhaust hose and window kit properly  see pages 7  amp  8    2  Plug the Power Cord into an electrical outlet   3  Tum on the unit by pressing the POWER button on the control panel        4  Press the Mode button until the            appears on      Multi color display  5  Press the    or Y buttons until the desired room temperature appears on the control panel  display  The temperature ranges from 61 F   88   F  16 C  31         6  Select the desired fan speed by pressing the FAN SPEED button        NOTE  During hot days  the unit will cool the room most efficiently by setting the temperature at the lowest  setting and the fan speed on high  Reducing the length of the exhaust duct  insulating the exhaust hose and  window kit  and keeping direct sunlight to a minimum will also improve the cooling efficiency    NOTE  When the unit is running on cooling mode  the exhaust hose is required and must be vented outside  using the supplied window kit     Dehumidifier Mode    1  Install the exhaust hose and window kit properly  see pages 7  amp  8    2  Plug the Power Cord into an electrical outlet   3  Tum on the unit by pressing the POWER Button on the control panel     4  Press the MODE bution until the             appears on the control panel display     NOTE  The unit operates at low fan speed during dehumidifier mode  The unit cools room slightly during  the dehumidification  Keep the windows and doors closed to aid the effectivenes
11. e back of the unit  gure       3  Connect the exhaust hose to the exhaust connector    aligning the filed grove  igure     4  Open the window or door and adjust the length of the  window kit ia fit the opening   figura d  f necessary      mark the kit and cut one end down lo properly it the  opening  figures e  amp  0    5  Attach the window kit adapter to the window kit  igure   6  Place the window kit back into the window and attach  the exhaust hose to the window kit adapter   gures h  0 Close the window tightly   igure  Your Portable  Air Conditioner is now ready to cool              NOTE  When using the venting system  keep the exhaust  hose as straight as possible  The exhaust hose can be     shortened  but t is not recommended to increase the  length of the exhaust hose  Do not use an extension cord  wilh your portable air conditioner    When using to a sliding door  it is recommend to make  the air outlet up to air inlet        NOTE  The Portable Air Conditioner above may differ from the unit described in this manual  The above directions and images  show general directions for all Soleus Air single hose portable air conditioners           CONTROL PANEL  DISPLAY   amp  OPERATING INSTRUCTIONS       CONTROL PANEL  amp  MULTI COLOR DISPLAY                                           i ee  se  we       uses                                      1   7                 POWER 7    7  oS     Sa  MULTLCOLOR DISPLAY      Auto Mode      Cool Mode      Dehumidity Mode  D  Fan Mode  E
12. er consumption is measured when the fan runs at the highest speed setti                  specifications are for reference only  For actual data  please refer to the rating label on the back of the unit      Ifthe environment temperature is higher than the max operating temperature or lower than the minimum operating temperature   the air conditioner may not work properly                                                                 Model Number            2         Reference Number APA12HP  Cooling Capacity 12 000 BTU Hr  Heating Capacity 12 000 BTU Hr  Dehumidifying Capacity 63 pisiday  Power Consump    Cooling 11 0w  tion Heating 1145W  Air Flow Volume 240         Power Source 115 V7 60 HZ  Rated Current Sookie 107  Heating 10 38     Sound Pressure Level  lt 55 dB A   Weight 70 ibs  Dimensions  W x D x H  137   x 22 125  x 27 75   Refrigerant RATOA       DISCLAIMER          INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE  PRESENTATION OF THE MANUFACTURER  SOLEUS HOME COMFORT HAS NOT CONDUCTED INDEPENDENT  TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN                      LCDI POWER CORD AND PLUG    This air conditioner is equipped with an LCDI  Leakage Current Detection and Interruption  power cord and  plug as required by US National Electric Code 440 65  This cord consists of a length of shielded flexible cord  with no termination on the load side and a LCDI attachment plug on the line side        The LCDI power
13. he A or Y buttons to change the clock to the desired time for the unit to automatically tum on      gt   Press the TIME OFF button and the display on the unit will flash                     A or    but   tons to change the clock to the desired time for the unit to automatically turn off  The TIME OFF  indicator will flash for 3 seconds to activate your programmed on and off times     6  Time Display   In the diagram on page 9  the letter    J    points to the adjustable time display  To adjust the  time  Press FAN SPEED and SWING together  at the same time   This will activate the time display fea   ture  Next  let go of the FAN SPEED and SWING buttons  and press the    button to adjust the hours  and  press V to adjust the minutes    oo   multi color display  To stop oscillation  press the S1   adjusted manually      To start horizontal oscillation  press the Swing button once      lt           icon will appear on the  ig button again  Vertical air flow direction can be    7          NOTE  The timer will remember your settings when itis set  If you set the timer while in Air Conditioning  mode  the timer will automatically turn the unit on and off in air conditioning mode according to the desired  programmed times  The timer will also remember the temperature settings  fan speed  and oscillation setting      The timer works when the unit is in Air Conditioner mode  Dehumidifier mode  Fan mode  Heat mode and  Auto mode                 OPERATING THE UNIT USING THE CONTROL PANE
14. n pan is full  screw the drain plug back onto the drainage hole to stop the water flow  Empty the drain          Repeat until all the water is emptied           Once the water container has been emptied  screw the plug back onto the drain hole  Do not allow the  water to drip continuously into the drain pan  as it might easily overflow     DRAIN HOLE    DRAIN PLUG                                              a a                                OPERATING THE UNIT USING THE REMOTE CONTROL       REMOTE CONTROL TIMER TEMP INCREASE  SWING  LOUVER  MODE BUTTON              FIC FAN SPEED  TIMER BUTTON SLEEP MODE  TIMERITEMP DECREASE POWER BUTTON       REMOTE CONTROL OPERATING INSTRUCTIONS  1  Power On and Off   Press the ON OFF button on the remote to turn the unit on or off     2  Mode Selection   Press the MODE Button repeatedly to cycle between the different modes  Auto  Air  Conditioner  Dehumidifier  Fan only  and Heater mode        3  Fan Speed   Press the FAN speed button to cycle through low  medium  and high fan speeds        4  Temperature Setting   When the unit is in Air Conditioner mode you can select your desired tempera   ture  Press the    or    to select your desired temperature setting  The temperature on the multi color  display on the control panel will increase or decrease accordingly  Pressing the   F   C button will change  the temperature select between   F and   C        5  Sleep Mode   See    SLEEP MODE    on page 12     6  Swing   To tum on oscillation  pre
15. prevent color fading   2  Clean the surface with a damp cloth and dry it with a soft towel     Storing the Unit for an Extended Period of Time or Transporting the unit       1  Empty any excess water by unplugging the water drain   the bottom      stop in the back of the unit  located at       2  Unplug the unit         The unit should be stored in    cool dry place           WARRANTY      One Year Limited Warranty   Soleus Home Comfort warrants the accompanying Soleus Air Portable Air Conditioner with Heat Pump technology   to be free of defects in material and workmanship for the applications specified in its operation instruction for a period    of ONE  1  year from the date of original retail purchase in the United States     Ifthe unit exhibits a defect in normal use  Soleus Home Comfort will  at its option  either repair or replace it  free of  charge within a reasonable time after the unit is retumed during the warranty period           Asa condition to any warranty service obligation  the consumer must present this Warranty Certificate along with a     copy of the original purchase invoice   THIS WARRANTY DOES NOT COVER      Damage  accidental or otherwise  to the unit while in the possession of a consumer not caused by a defect in  material or workmanship      Damage caused by consumer misuse  tampering       failure to follow the care and special handling provisions  in the instructions     Damage to the finish of the case  or other appearance parts caused by wear  
16. s of the unit in removing the  moisture from the room     NOTE  When the unit is running in dehumidifier mode  the exhaust hose is required and must be vented out   side using the supplied window kit  The unit will not perform in dehumidifier mode when the room tempera   ture is lower than 6        Fan Mode    1  Plug the Power Cord into an electrical outlet    2  Tum on the unit by pressing the POWER button on the control panel    3  Press the MODE button until the              icon appears on the control panel display    4  Select the fan speed by pressing the FAN SPEED button    5  To circulate more air  press the SWING button on the remote control  The louvers will oscillate back and  forth spreading more air throughout the room        NOTE  It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan mode     Heat Mode    1  Install the exhaust hose and window kit properly  see pages 7  amp  8    2  Plug the power cord into a grounded outlet       Tum on the unit by pressing the On Off button on the control panel       4  Press the Mode button unti icon appears on the multi color display    5  Press the    or Y button until the desired room temperature appears on the multi color display  The tem   perature ranges from 61 F   88  F  16      31        6  Select the fan speed by pressing the Fan button  It is recommended to use the low fan speed     NOTE  When the unit is running on heating mode  the exhaust hose is required and must be
17. ss the SWING button on the remote control  Once you press SWING   the louvers on the unit will oscillate back and forth     7  Timer   To program the timer  press the TIMER button on the remote control  Press the    or    buttons  to change the clock to the desired time for the unit to automatically turn on  Press the TIMER button  again to set the time for the unit to shut off  Press the    or Y buttons to change the clock to the desired  time for the unit to automatically turn off  The TIMER OFF indicator on the multi color display will  flash for 3 seconds to activate your programmed on and off times              14    T  MAINTENANCE    Note  Make sure power is off and the power cord is not plugged into an electrical outlet prior to  performing any maintenance on the unit     Clean or replace filter   If the air filter is blocked with a dust  th  recommended to clean the filter once every two weeks or as ni       irflow volume may reduce  It is  ed           1  Remove the filter from the filter compartment on the back of the unit     2  Wash the air filter by immersing it gently into warm water with a neutral detergent  Rinse the filter  and dry it thoroughly out of sunlight   3  Slide the filter back into the filter compartment after it is thoroughly dried   4  Ifthe filter is torn or unusable  order a new filter by calling the customer service number on the  warranty page of this manual   Clean the unit Housing  1  Keep the unit from being exposed directly to the sun to 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  User Manual - Lightspeed Technologies, Inc.  インターフェースコンバータ PHN-D88 ファームウェアアップデート手順書    Immunization Manual - Interlake Regional Health Authority  Samsung SGH-Z400 Kasutusjuhend  Origin Storage KB-MRVHY  CDX-GT620U - Sony Europe  Owners manual Manuel d`utilisation  Link 721    Copyright © All rights reserved. 
   Failed to retrieve file