Contents
1. quotations from a competitive source or used for manufacture by anyone other than Astronics Test Systems The information herein has been developed at private expense and may only be used for operation and maintenance reference purposes or for purposes of engineering evaluation and incorporation into technical specifications and other documents which specify procurement of products from Astronics Test Systems TRADEMARKS AND SERVICE MARKS All trademarks and service marks used in this document are the property of their respective owners e Racal Instruments Talon Instruments Trig Tek ActivATE Adapt A Switch N GEN and PAWS are trademarks of Astronics Test Systems in the United States DISCLAIMER Buyer acknowledges and agrees that it is responsible for the operation of the goods purchased and should ensure that they are used properly and in accordance with this document and any other instructions provided by Seller Astronics Test Systems products are not specifically designed manufactured or intended to be used as parts assemblies or components in planning construction maintenance or operation of a nuclear facility or in life support or safety critical applications in which the failure of the Astronics Test Systems product could create a situation where personal injury or death could occur Should Buyer purchase Astronics Test Systems product for such unintended application Buyer shall indemnify and hold Astronics Test Systems its offi
2. batteries damage from battery leakage or problems arising from normal wear such as mechanical relay life or failure to follow instructions This warranty is in lieu of all other warranties expressed or implied including any implied warranty of merchantability or fitness for a particular use The remedies provided herein are buyer s sole and exclusive remedies For the specific terms of your standard warranty contact Customer Support Please have the following information available to facilitate service 1 Product serial number 2 Product model number 3 Your company and contact information You may contact Customer Support by E Mail atshelpdesk Qastronics com Telephone 1 800 722 3262 USA Fax 1 949 859 7139 USA RETURN OF PRODUCT Authorization is required from Astronics Test Systems before you send us your product or sub assembly for service or calibration Call or contact Customer Support at 1 800 722 3262 or 1 949 859 8999 or via fax at 1 949 859 7139 We can also be reached at atshelodesk astronics com If the original packing material is unavailable ship the product or sub assembly in an ESD shielding bag and use appropriate packing materials to surround and protect the product PROPRIETARY NOTICE This document and the technical data herein disclosed are proprietary to Astronics Test Systems and shall not without express written permission of Astronics Test Systems be used in whole or in part to solicit
3. 0972 Rev B Fault When a NC Normally Closed contact has a discontinuity longer than the set in time interval it is a FAULT for NO Normally Open contact continuity for a period longer than the set in time interval constitutes a fault When a FAULT is detected the FAULT LED for that channel illuminates and a 12 V signal is present on the FAULT output terminal on the rear panel To remove the fault the FAULT RESET switch should be depressed this removes the fault from all channels The FAULT RESET can be accomplished remotely by applying 12 volts to the RESET terminal on the rear panel Switch S1 Figure 2 1 Switch S1 Input Voltage Setting Operation 2 2 Astronics Test Systems Publication No 980972 Rev B 850A B User Manual Chapter 3 Calibration The circuitry of the 850A B Contact Chatter Detector is stable and should require calibration only in the case of part failure Astronics Test Systems recommends a 12 month calibration period or longer Refer to Figure 3 1 for both calibration adjustments Remove top cover of the 850A B to access components Timing Interval Adjustment Connect a frequency counter to Pin 3 of U3 Figure 3 1 Set the MICROSEC MILLISEC Switch to MICROSEC Set the timing adjust R33 for an indication of 1 MHZ 10 kHz Place the MICROSEC MILLISEC switch to MILLISEC The counter should indicate 1000 10 Hz SH vn Je e Figure 3 1 Calibration Adjustments Astronics Test Systems
4. ASTRONICS TEST SYSTEMS Trig Tek 850A B Contact Chatter Detector User Manual Publication No 980972 Rev B Astronics Test Systems Inc 4 Goodyear Irvine CA 92618 Tel 800 722 2528 949 859 8999 Fax 949 859 7139 atsinfo astronics com atssales astronics com atshelpdesk astronics com http www astronicstestsystems com Copyright 2011 by Astronics Test Systems Inc Printed in the United States of America All rights reserved This book or parts thereof may not be reproduced in any form without written permission of the publisher THANK YOU FOR PURCHASING THIS ASTRONICS TEST SYSTEMS PRODUCT For this product or any other Astronics Test Systems product that incorporates software drivers you may access our web site to verify and or download the latest driver versions The web address for driver downloads is http www astronicstestsystems com support downloads If you have any questions about software driver downloads or our privacy policy please contact us at atsinfo astronics com WARRANTY STATEMENT All Astronics Test Systems products are designed to exacting standards and manufactured in full compliance to our AS9100 Quality Management System processes This warranty does not apply to defects resulting from any modification s of any product or part without Astronics Test Systems express written consent or misuse of any product or part The warranty also does not apply to fuses software non rechargeable
5. Calibration 3 1 850A B User Manual Publication No 980972 Rev B Contact Current Adjustment Calibration 3 2 1 2 3 4 Set the full scale current adjust R32 for 10 01 milliamps indication on the GU ENE Connect a current meter to Channel 1 Input Set to read up to 11 milliamps Place the X1 X0 1 switch to X1 Place the CONTACT CURRENT DIAL to 10 current meter Connect the current meter to each of the other nine channels and get 10 0 2 milliamps indication Place the X1 X0 1 Switch to X0 1 All channels should indicate 1 0 0 1 milliamps Set dial to 5 and X1 X0 1 Switch to X1 All channels should indicate 5 0 0 1 milliamps Astronics Test Systems
6. Introduction 1 1 850A B User Manual of time than is set in by the Timing Interval Switch illuminated until reset either by the front panel reset switch or remotely via a reset terminal The unit has a terminal strip where the FAULT condition of each channel Publication No 980972 Rev B can be recorded Low NO FAULT or HIGH FAULT Either Normally Closed NC or Normally Open NO contacts can be monitored A toggle switch on each channel permits selection of NC or NO type contacts Specifications Channel Inputs 10 each BNC type connectors 850A Terminal interface 850B Current Source Compliance 3 Volt maximum Current Source Accuracy Timing Interval Accuracy 3 FS Setting 5 LSB Fault Reset Terminal Permits FAULT Reset from remote location Fault Output Terminals Provide a 12 Volt for Fault and 0 for NO Fault for each channel Controls Power Switch Turns Power ON or OFF Contact Current Dial Permits continuous setting of 1 11 Operates in conjunction with the X1 X0 1 switch to provide 1 to 11 milliamps current through the contact being tested X1 X0 1 Switch Multiplies the current dial by X1 or X0 1 Timing Interval MICROSEC MILLISEC Switch Toggle switch to select either microseconds or milliseconds as the time interval Timing Interval 001 999 Thumbwheel Switch Works in conjunction with the MICROSEC MILLISEC
7. cers employees subsidiaries affiliates and distributors harmless against all claims arising out of a claim for personal injury or death associated with such unintended use FOR YOUR SAFETY Before undertaking any troubleshooting maintenance or exploratory procedure read carefully the WARNINGS and CAUTION notices RISK OF ELECTRICAL SHOCK human life and safety and is capable of DO NOT OPEN inflicting personal injury h CAUTION This equipment contains voltage hazardous to If this instrument is to be powered from the AC line mains through an autotransformer ensure the common connector is connected to the neutral earth pole of the power supply Before operating the unit ensure the conductor green wire is connected to the ground earth conductor of the power outlet Do not use a two conductor extension cord or a three prong two prong adapter This will defeat the protective feature of the third conductor in the power cord 8 Maintenance and calibration procedures sometimes call for operation of the unit with power applied and protective covers removed Read the procedures and heed warnings to avoid live circuit points SENSITIVE ELECTRONIC DEVICES Do Before operating this instrument 1 Ensure the proper fuse is in place for the power source to operate 2 Ensure all other devices connected to or in proximity to this instrument are properly grounded or connected to the protective third wire earth ground If th
8. e instrument fails to operate satisfactorily shows visible damage has been stored under unfavorable conditions has sustained stress Do not operate until performance is checked by qualified personnel Publication No 980972 Rev B 850A B User Manual Table of Contents Chapter Taste 1 1 MEMEO CEN OI esha San acs bee en 1 1 Specifications uante 1 2 Eent re EE 1 2 fe Iert i EAE EE ruver 1 3 e EE 1 3 KEE 2 1 KEES 2 1 Current Setting eninin i ea a aa aieea ai EENEG 2 1 Time Interval Switch Settings A 2 1 Contact Connections and Gwitches nenn nnt 2 1 e II 2 2 Ghapler Ju 3 1 G llbr tlon na oe ene eee dts AGR 3 1 Timing Interval Adiustmert cece cece arrr Earran RE AEA RE REER NERES EOS 3 1 Contact Current Adlustment renn nrnnnnnvnrerrennnrnnnnnnnnrnrennnrrnnnnnnnnnnenrnrrensnrnsnnnnnnenne 3 2 Astronics Test Systems 850A B User Manual This page intentionally left blank Publication No 980972 Rev B Astronics Test Systems Publication No 980972 Rev B 850A B User Manual List of Figures Figure 1 1 Trig Tek 850A Contact Chatter Detector rrrrrnrvvnrrnnvvrnnrnnvrrnrrnnrrnnrrrnrrrnrrrsrrrnrrrsrnnneenn 1 1 Figure 1 2 Trig Tek 850B Contact Chatter Detector rrrrrnrrrnnrnnvvvnnrnnvrvnrrnnrvnnrrnnrrnnrrrsrrrnrrssrnnnrnnn 1 1 Figure 2 1 Switch S1 Input Voltage Geng 2 2 Figure 3 1 Calibration Adjustments cccceceeeceeeeeeeeeeteeeeeceaeeeeaaeeeeeeeseaeeeseaeeseaaeseeeeeseaeessaeenene
9. eeed 3 1 Asironics Test Systems 850A B User Manual Publication No 980972 Rev B DOCUMENT CHANGE HISTORY Revision Date Description of Change A 2 23 2011 Document Control release ECN00301 adding 850A configuration 7 STE information Added ITAR statements B 8 29 2012 ECN01438 Administrative document change Remove ITAR statements Astronics Test Systems Publication No 980972 Rev B 850A B User Manual Chapter 1 Introduction The 850A B Contact Chatter Detector Figures 1 1 and 1 2 is designed to provide a means of monitoring the continuity of switch or relay contacts while being subjected to environmental stress The unit has 10 channels each with a separate current source to activate the contacts Contact current dial and X1 X0 1 switch sets the current of all the channels simultaneously for 0 1 to 11 milliamps The difference between the two models is that the 850A uses BNCs for the channel inputs and the 850B uses screw terminals CONTACT CHATTER DETECTOR MODEL 850A To _ TANG INTERVAL i arg CONTACT CHATTER DETECTOR MODEL 8508 P TYING INTERVAL waou 1 Figure 1 2 Trig Tek 850B Contact Chatter Detector Timing Interval Controls provide for setting from 1 to 999 microseconds or 1 to 999 milliseconds for the maximum time a discontinuity can exist Each channel has a FAULT LED which will illuminate if a discontinuity exists for a longer period Asironics Test Systems
10. switch to select 001 to 999 either microsecond or millisecond time interval FAULT Reset Switch Resets all FAULT LED S when depressed Introduction 1 2 Astronics Test Systems The LED will remain Publication No 980972 Rev B 850A B User Manual Indicators Illuminates when power is applied to the Bod EEE circuitry One for each channel If a fault for the channel occurs the LED will illuminate and FAULT LEDS 10 ea remain on until the RESET switch is depressed Power Operates from either 117 or 234 Volt RMS Power AC power 50 or 60 Hz at approximately 15 watts Astronics Test Systems Introduction 1 3 850A B User Manual Publication No 980972 Rev B This page intentionally left blank Introduction 1 4 Astronics Test Systems Publication No 980972 Rev B 850A B User Manual Chapter 2 Operation The 850A B Contact Chatter Detector contains ten contact monitors in a chassis 19 inches wide by 3 1 2 inches high and 8 inches deep The unit operates using either 117 or 234 Volts RMS power The switch S1 next to the transformer cover must be removed to view see Figure 2 1 is marked 117 and 234 Set S1 to the appropriate position for the power that is to be used Damage can be caused to the circuitry if S1 is in the 117 position and 234 V RMS AC power is applied With S1 set properly apply the AC power and the unit is ready to operate Current Setting Before connec
11. ting any contact to the Contact Chatter Detector set the current that will flow in the contact Damage could be caused if the current was set higher than the contact current rating The current is set between 0 1 to 11 millliamps using the contact current dial and the X1 X0 1 switch to provide two ranges When the X1 X0 1 switch is in the X0 1 position the dial sets 0 1 to 1 1 milliamps and the X1 position provides 1 to 11 milliamps The current setting is for all ten channels To prevent damage to the contacts each channel voltage is clamped below 3 Volts Time Interval Switch Settings The Time Interval Switches set the time discontinuity can exist in a NC contact before it is considered a FAULT for a NO contact the opposite or closure for longer than the set time interval would constitute a FAULT The time interval can be set from 1 to 999 microseconds or 1 to 999 milliseconds using the three digit thumb switch in conjunction with the MICROSEC MILLISEC switch The accuracy is the setting 3 LSD These switches should be set to the appropriate setting for the contact or contacts being monitored Contact Connections and Switches Connect the contact to be monitored to a channel input BNC 850A or terminal 850B Set the Contact Switch to the required position NC if the contact is in the closed position and NO if the contact is being tested in the open position Astronics Test Systems Operation 2 1 850A B User Manual Publication No 98