1. 98 6 4 Viewing Memory Data 0602714 06 32pm View Men 0 3078 MOU UT WOUTLO LD TL UL To view data that was stored into memory of the meter proceed as described Press the F3 key SAVE button to enter the system menu Select the menu item VIEWM With the key F3 DOWN Press the F1 ENTER to view the stored measurement values Press push button F2 PREV or F3 NEXT to scroll through the stored data 99 6 5 Viewing Graph Data 0602 14 06 32pm ViewGrap o Ge To view the graph data that was stored into memory of the meter proceed as described Press the F3 key SAVE button to enter the system menu Select the menu item VIEWG with the key F3 DOWN Press the F1 ENTER to view the stored measurement values Press push button F2 PREV or F3 NEXT to scroll through the stored data Press the F1 key ENTER the stored value can be viewed more detail Press the F2 or F3 keys on the course of the saved diagram can be viewed and displayed the individual measured values 100 6 6 Recording Measurement Data Auto range 06 32pm 366 55 Set Duration 00Days OOHrs 01Min O Set Sample Interval 00Min 01Sec O Start Record Press the F3 key SAVE Then press the F3 key DOWN to select the menu item RECORD and press the F1 key ENTER a SET DURATION Now use the key F3 DOWN the menu item Set Duration and confirm by pressing Fi ENTER
2. Durchschnitts und Minimalmesswerte in der Sekund ranzeige mit ihren jeweiligen Laufzeiten Um eine MINMAX Aufzeichnung zu beenden dr cken Sie die Taste F2 STOP Eine Zusammenfassung der Informationen wird in der Anzeige angezeigt und die Drucktasten wechseln Ihre Funktionen damit die Speicherung der Daten durchgef hrt werden kann Um die Minimal Maximalwertaufzeichnung zu beenden dr cken Sie die Taste F4 CLOSE um die MIN MAX Aufzeichnung ohne die aufgezeichneten Daten zu speichern Um die MIN MAX Bildschirmdaten zu speichern m ssen Sie die MIN MAX Sitzung durch Dr cken der Taste F2 STOP beendet werden Als n chstes dr cken Sie die Taste F3 SAVE 15 4 6 Erfassung der Spitzenwerte PEAK 08 12pm 0 2676 0 6354 V Poent 0 263 V PMIN 0 5894 v e Mit dem Funktionswahlschalter die Spannung bzw Strommessfunktion ausw hlen e Ger t auf die Wechselspannungs bzw Wechselstrommessfunktion AC durch Dr cken der Taste F2 MODE umschalten In der LCD Anzeige leuchtet das Funktionssymbol AC auf e Durch Dr cken der Taste F4 MAX die Maximalwerthaltefunktion aktivieren e Erneut die Taste F4 PMAX dr cken um die Spitzenwerthaltefunktion PEAK zu aktivieren 16 4 7 Relativwertmessfunktion 0 0430 Reference 0 3079 V V Die Relativwert Messfunktion gestattet die Messung und Anzeige von Signalen bezogen auf einen definie
3. Mit der Setup Option k nnen die Standardwerte des Messger tes auf den Auslieferungszustand zur ckgesetzt werden Taste F3 SAVE dr cken um das Ger te Men aufzurufen Mit der Taste F3 DOWN den Men punkt SETUP ausw hlen und mit der Taste F1 ENTER best tigen Im LCD Display erscheint eine weitere Men auswahl Mit F3 DOWN den Men punkt RESET ausw hlen und mit der Taste F1 ENTER best tigen Im LCD Display erscheint eine Sicherheitsabfrage welche erneut durch Dr cken der Taste F1 OK best tigt werden muss damit der Ger te Reset durchgef hrt wird 46 7 2 Messger te Informationen In der Funktion Meter Info des Messger t k nnen zus tzliche Informationen wie z B die Seriennummer und Firmware Version angezeigt werden ffnen Sie das Ger te Men durch Dr cken der Taste F3 SAVE Wahlen Sie mit der Taste F3 DOWN den SETUP und anschlie end den Men punkt METER INFO aus und best tigen Sie mit der Taste F1 ENTER 7 3 Formatierung einstellen Auto range 08 32pm 6 lt a Format Beeper O Numeric Format Date Format Time Format ffnen Sie das Ger te Men durch Dr cken der Taste F3 SAVE W hlen Sie mit der Taste F3 DOWN den Men punkt SETUP und anschlie end FORMAT aus und best tigen Sie mit der Taste F1 ENTER Mit den Tasten F2 UP und F3 DO
4. 500 mA 0 01 mA 0 3 8 St 10 A 0 001 A 0 5 8 St Wechselstrom ACA lt 1 kHz lt 5 kHz 500 uA 0 01 pA 5000 uA 01 pA 50 mA 0 001 mA 0 8 5 St 3 0 5 St 500 mA 0 01 mA 10 A 0 001 A 20A maximal 30 Sekunden mit reduzierter Genauigkeit Alle Wechselstrombereiche sind von 5 bis 100 des Messbereiches spezifiziert 59 Alle Rechte auch die der bersetzung des Nachdruckes und der Vervielf ltigung dieser Anleitung oder Teilen daraus vorbehalten Reproduktionen jeder Art Fotokopie Mikrofilm oder ein anderes Verfahren nur mit schriftlicher Genehmigung des Herausgebers gestattet Letzter Stand bei Drucklegung Technische nderungen des Ger tes welche dem Fortschritt dienen vorbehalten Hiermit best tigen wir dass alle Ger te die in unseren Unterlagen genannten Spezifikationen erf llen und werkseitig kalibriert geliefert werden Eine Wiederholung der Kalibrierung nach Ablauf von 1 Jahr wird empfohlen PeakTech 10 2014 Pt 60 1 Safety Precautions This product complies with the requirements of the following European Community Directives 2004 108 EC Electromagnetic Compatibility and 2006 95 EC Low Voltage as amended by 2004 22 EC CE Marking Overvoltage category III 1000V overvoltage category IV 600V pollution degree 2 CAT I For signal level telecommunication electronic with small transient over voltage CAT Il For local level appliances main wall ou
5. Here you can set the duration of the measurement Increase with the F2 key the setting of individual points hour minute second Move the digit to the next point with the F3 key gt gt If you finished the settings confirm it with the F1 key Ok SET SAMPLE INTERVAL Press the F3 key DOWN to select the next item Set Sample Interval sampling rate and confirm by pressing the F1 key ENTER Increase with the F2 key the setting of individual points hour minute second Move the digit to the next point with the F3 key gt gt If you finished the settings confirm it with the F1 key Ok 101 START RECORD Press the F1 key ENTER to start recording The recording session is executed until the internal memory is exhausted the voltage of the battery for supplying the meter is insufficient the function selector switch is turned to another measurement function or by pressing F4 STOP to complete the measurement 6 7 Viewing Trend Data The recorded measurement data which are stored in the internal memory of the instrument can be viewed at a later time Viewing this data is performed by the SAVE menu Press the push button F3 SAVE opens the menu of the device memory Press the push button F3 DOWN until the menu item VIEWR is selected and press F1 ENTER 08 27pm Recording mV 351 44 Start Times 06 02 14 08 26 09pm Duration 00days OOhrs OOmin 37sec
6. Pr fleitungen in Reihe anschlie en auf korrekte Polarit t achten Spannung an die Messschaltung anlegen und Messwert in der LCD Anzeige des Ger tes ablesen Beim Messen negativer Gleichstr me erscheint ein Minussymbol links von der Messwertanzeige 33 5 11 Wechselstrommessungen Achtung Aus Sicherheitsgr nden keine Strommessungen in Schaltungen mit Spannungen von mehr als 1000 V DC AC vornehmen Gleichstrommessungen im 10 A Bereich auf maximal 30 Sekunden beschr nken L ngere Messzeiten in diesem Bereich k nnen zum Ausl sen der internen Sicherung f hren 34 Achtung 1 Entsprechend der zu messenden Stromgr e Funktionswahlschalter entweder in Stellung A mA oder 10A drehen Ger t auf die Wechselstrommessfunktion AC durch Dr cken der Taste F2 MODE umschalten In der LCD Anzeige leuchtet das Funktionssymbol AC auf Abh ngig von der zu messenden Stromst rke rote Pr fleitung an den wA mA oder den 10 A Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en Bei unbekannter Stromgr e aus Sicherheitsgr nden 10 A Bereich w hlen und bei entsprechender Messwertanzeige ggf auf einen mA Messbereich umschalten Zu messende Schaltung spannungslos schalten und am gew nschten Messpunkt ffnen Pr fleitungen in Reihe anschlie en Spannung an die Messschaltung anlegen und Messwert in der LCD Anzeige des Ger tes ablesen 35 5 12 4 20mA
7. Samples 37 Riog0002 Press the push button F1 TREND to enter the trend display of the stored measurement values 102 Press the push button F2 button to increase the resolution of the graphic display Press the push button F3 gt gt button to move the cursor Press the push button F4 BACK button to exit the function of the trend display 103 6 8 Info The device has an internally stored help function that allows the user even without a manual to consult instructions for use of each function The Help function is available on the SAVE menu Press the push button F3 SAVE to call up the SAVE menu Press the push button F3 DOWN until the INFO icon is selected and press F1 ENTER fno Graph According to graphically display measurement information Fno Mode Releted to the rotary switch function Fno Save Accesses the memory management menu for saving measurement setting up recording sessions or viewing and Geleting stored measurements from memory With the push buttons F2 and F3 it is possible to scroll forward or back inside the Help function To return to the SAVE menu press F4 key CLOSE 104 7 Setup Options All settings for the device can be done via the Device menu Auto range 14 20 dr BET Tai Meter Info Info A A Temperature Press push button F3 DOWN to select SETUP and press F1 ENTER
8. jack 4 Read the voltage in the display 78 5 1 1 AC DC 1 Set the function switch to the V position 2 Insert the black test lead into the negative COM jack Insert the red test lead into the positive V Q CAP Hz Temp jack 3 Press the push button F2 to indicate AC DC on the display 4 Read AC DC measurement value in the display O412om Vaic oc 0 0276 0 0276 V 5 2 Voltage measurement mV Caution Do not measure DC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur during the ON or OFF operations that can damage the meter Caution Understanding Phantom readings In some DC and AC voltage ranges when the test leads are not connected to any circuit the display might show a phantom reading This is normal The meter s high input sensitivity produces a wandering effect When you connect the test leads to a circuit accurate reading appears 79 Set the function switch to the mV position Press the push button labeled F2 MODE to select mV DC or mV AC Insert the black test lead into the negative COM jack Insert the red test lead into the positive V Q CAP Hz Temp jack Read the mV voltage in the display 80 5 3 AC voltage measurements Warning Risk of Electrocution The probe tips may not be long enough to contact the live parts inside some 230 V outlets for appliances because the contacts are recessed
9. to confirm 7 1 Resetting the Meter With the Setup Options can set the default values of the meter will be reset to the factory settings Press the F3 SAVE button to open the Save menu Press the push button F3 DOWN to select the menu item SETUP and confirm it with F1 ENTER In the LCD display another menu selection appears Select F3 DOWN the menu option RESET and press the F1 key ENTER The LCD displays a confirmation prompt which has to be confirmed again by pressing the F1 key OK for the device reset is performed appears 105 7 2 Meter Info The Meter Info selection lists the serial number firmware version are displayed Open the Save menu by pressing the push button F3 SAVE and with the push button F3 DOWN select the menu point SETUP and after that METER INFO and confirm it with the push button F1 ENTER 7 3 Setting Format Auto range 08 32pm 6 j Gi l Format i Beeper O Numeric Format O Date Format O Time Format Open the Save menu by pressing the push button F3 SAVE Press the push button F3 DOWN to select the menu item SETUP and after that FORMAT and confirm it with the push button F1 ENTER With the push buttons F2 UP and F3 DOWN choose between the menu items Beeper Numeric Format Date Format and Time Format Press the push button F1 EDIT to select the respective menu item 106 Nu
10. 500 V 0 01 V 0 05 5 dot 1000 V 0 1 V 0 1 5 dgt When using the relaiv mode REL Q to compensate for offsets DC Votlage AC DC Range Resolution lt 1kHz lt 5kHz 5V 0 0001 V 50 V 0 001 V 1 2 20 D 500 V 001 V dgt REIN 1000 V 0 1 V 116 Range Resolution Accuracy 50 Q 0 01 Q 0 2 10 dgt 5 kQ 0 0001 kQ A Resistance 0 50 ko 0001 ko oot 5dgt 500 KQ 0 01 ka o 5 MO oooi Mo 09 Sdgt 50 MQ 0 001 MQ 2 0 10 dot When using the relative mode REL Q to compensate for offsets Range Resolution Accuracy e as 0 1 C 1 0 3 0 C Temperature 200 a 0 1 F 1 0 5 4 F type K 1 Does not include error of the thermocouple probe 2 Accuracy specification assumes ambient temperature stable to 1 0 C 5nF 0 001 nF 1 5 20 dgt 50 nF 0 01 nF 1 5 8 dgt 500 nF 01 nF 1 0 8dgt 5ur 0 001 F 1 5 8 dgt Capacitance 50 uF 0 01 uF 1 0 8 dgt 500 uF 01 ur 1 5 8 dgt 10 mF 0 01 mF 2 5 20 dot With a film capacitor or better using relative mode REL A to zero residual 0 1 99 90 0 01 1 2 2 dgt Duty Cycle Pulse width 100 us 100ms Frequency 5 Hz 150 kHz 1 17 Frequency electronic 50 Hz 0 001 Hz 500 Hz 0 01 Hz 5 kHz 0 0001 kHz 3 50 kHz 0 001 kHz 0 01 5 dat 500 kHz
11. Spannungsbereich V Q vornehmen 2 xx amp Ger t Pr fleitungen und sonstiges Zubeh r vor Inbetriebnahme auf eventuelle Sch den bzw blanke oder geknickte Kabel und Dr hte berpr fen Im Zweifelsfalle keine Messungen vornehmen Verwenden Sie ausschlie lich 4mm Sicherheitstestkabels tze um eine einwandfreie Funktion des Ger tes zu gew hrleisten Messarbeiten nur in trockener Kleidung und vorzugsweise in Gummischuhen bzw auf einer Isoliermatte durchf hren Messspitzen der Pr fleitungen nicht ber hren Warnhinweise am Ger t unbedingt beachten Ger t darf nicht unbeaufsichtigt betrieben werden Bei unbekannten Messgr en vor der Messung auf den h chsten Messbereich umschalten Ger t keinen extremen Temperaturen direkter Sonneneinstrahlung extremer Luftfeuchtigkeit oder N sse aussetzen Starke Ersch tterung vermeiden Hei e L tpistolen aus der unmittelbaren N he des Ger tes fernhalten Vor Aufnahme des Messbetriebes sollte das Ger t auf die Umgebungstemperatur stabilisiert sein wichtig beim Transport von kalten in warme R ume und umgekehrt berschreiten Sie bei keiner Messung den eingestellten Messbereich Sie vermeiden so Besch digungen des Ger tes Drehen Sie w hrend einer Strom oder Spannungs messung niemals am Messbereichswahlschalter da hierdurch das Ger t besch digt wird Messungen von Spannungen ber 35V DC oder 25V AC nur in bereinstimmung mit den relevanten Sicherhe
12. deep in the outlets As a result the reading may show 0 volts when the outlet actually has voltage on it Make sure the probe tips are contacting the metal contacts inside the outlet before assuming that no voltage is present Caution Do not measure AC voltages if a motor on the circuit is being switched ON or OFF Large voltage surges may occur during the ON or OFF operations that can damage the meter 81 Set the function switch to the V position Press F2 button to select AC Insert the black test lead into the negative COM jack and the red test lead into the positive V Q CAP Hz Temp jack Touch the test probe tips to the circuit under test Read the voltage in the display The display will indicate the proper decimal point value and symbol 82 5 4 Frequency Measurement 1 Set the function switch to the Hz position 2 Insert the black test lead into the negative COM jack and the red test lead banana plug into the positive V Q CAP Hz Temp jack 3 Touch the test probe tips to the circuit under test 4 Read the frequency in the display The digital readings will indicate the proper decimal point symbols Hz kHz MHz and value 83 5 5 Resistance Measurements Warning To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Remove the batteries and unplug the line cords 84 1 Set th
13. meter is not in use This meter has Auto OFF that automatically shuts the meter OFF if max 30 minutes elapse between uses 2 If OL appears in the display during a measurement that value you are measuring exceeds the range you have selected Change to higher range 3 1 Preliminary Note 1 Check the supply voltage by setting the DMM switch to ON If the voltage is weak a BAT sign will appear on the right of display and you have to charge the battery 2 The warning sign next to the test leads jack is for warning that the input voltage or current should not exceed the indicated values This is to prevent damage to the internal circuitry 3 The function switch should be set to the range which you want to test before operation Note On some low AC and DC voltage ranges with the test leads not connected to a device the display may show a random changing reading This is normal and is caused by the high input sensitivity The reading will stabilize and give a proper measurement when connected to a circuit 68 3 2 Autoranging manual range selection When the meter is first turned on it automatically goes into Auto Ranging This automatically selects the best range for the measurements being made and is generally the best mode for most measurements For measurement situations requiring that the range be manually held perform the following 1 Press the RANGE button The AUTO indicator will extinguish and the
14. 0 01 kHz 5 MHz 0 0001 MHz 10 MHz 0 001 MHz not specified Sensitivity 2V rms min 20 to 80 duty cycle and lt 100kHz 5Vrms min 20 to 80 duty cycle and gt 100kHz Frequency electrical ne 001 z 0 5 of reading Sensitiviy 2Vrms DC Current DCA 500 nA 0 01 pA 5000 uA 0 1 pA 0 2 5 dgt 50 mA 0 001 mA 500 mA 0 01 mA 0 3 8 dgt 10 A 0 001 A 0 5 8 dgt AC Current ACA lt 1kHz lt 5kHz 500 pA 0 01 pA 5o00 HA Qi HA 0 8 5 3 0 5 500 mA 0 01 mA dat dat 10 A 0 001 A 20A 30 sec max with reduced accuracy All AC current ranges are specified from 5 of range to 100 of range 118 All rights also for translation reprinting and copy of this manual or parts are reserved Reproduction of all kinds photocopy microfilm or other only by written permission of the publisher This manual considers the latest technical knowing Technical changings which are in the interest of progress reserved We herewith confirm that the units are calibrated by the factory according to the specifications as per the technical specifications We recommend to calibrate the unit again after 1 year PeakTech 10 2014 Pt PeakTech Pr f und Messtechnik GmbH Kornkamp 32 DE 22926 Ahrensburg Germany 2 49 0 4102 42343 44 49 0 4102 434 16 B info peaktech de www peaktech de
15. A 10A Eingangsbuchse Eingangsbuchse f r AC DC Strommessungen von 500mA bis 10A 3 Hinweise zur Inbetriebnahme des Ger tes Achtung Messungen an Schaltungen mit hohen Spannungen AC und DC mit u erster Vorsicht und nur in bereinstimmung mit den relevanten Sicherheitsbestimmungen vornehmen Ger t nach Beendigung des Messbetriebes stets ausschalten Das Messger t verf gt ber eine interne Abschaltautomatik die das Ger t automatisch max 30 Minuten nach dem letzten Bet tigen einer Taste ausschaltet Bei Aufleuchten des Uberlaufsymbols OL bersteigt der gemessene Wert den gew hlten Eingangsbereich Bei Umschaltung auf einen h heren Messbereich erlischt die Anzeige automatisch 3 1 Vorbereitung zum Messbetrieb 1 Pr fen Sie vor der Messung die Versorgungsspannung des Akkus Ist sie zu schwach erscheint das Batteriesymbol rechts oben und der Akku muss wieder aufgeladen werden 2 Das Warndreieck neben den Eingangsbuchsen soll Sie warnen dass Messspannung oder Messstrom zum Schutz der internen Schaltung nicht den angegebenen Wert bersteigen d rfen 3 Der Funktionswahlschalter sollte vor der Messung auf den gew nschten Bereich eingestellt werden Hinweis In den niederen AC DC Messbereichen erscheint bei nicht angeschlossenen Pr fleitungen u U ein beliebig sich ndernder Wert in der LCD Anzeige Dies ist bei Ger ten mit hoher Empfindlichkeit normal und f r die Messgenauigkeit bedeutungslos 3 2 Umschal
16. Dr cken Sie die Taste F1 SAVE um die grafische Aufzeichnung zu speichern Dr cken Sie die Taste F4 BACK um in den normalen Messbetrieb zur ckzukehren 38 6 2 Speicherfunktion a f 7 Record Delete Setup Siw allen al In allen Messfunktion ist es m glich durch Dr cken der Taste F3 SAVE in das Systemment zu gelangen In all measurement function it is possible to enter the system menu by pressing F3 SAVE 6 3 Speichern einzelner Messdaten Zur Speicherung eines momentanen Messwertes wie beschrieben verfahren e Taste F3 SAVE dr cken um in das System Men zu gelangen e Mit der Taste F3 DOWN den Men punkt SAVE ausw hlen e Taste F1 ENTER dr cken um den Messwert zu speichern 39 6 4 Speicherdaten anzeigen 06 0214 06 32pm View Men 0 3078 RL LO NENNT TUT Zum Anzeigen von Messdaten die im Speicher des Messger tes gesichert wurden wie beschrieben verfahren e Taste F3 SAVE dr cken um in das System Men zu gelangen e Mit der Taste F3 DOWN den Men punkt VIEWM ausw hlen e Taste F1 ENTER dr cken um die gespeicherten Messwerte anzuzeigen e Dr cken der Taste F2 PREV oder F3 NEXT um durch die gespeicherten Daten zu bl ttern 40 6 5 Diagrammdaten anzeigen 0602 14 06 32pm ViewGrap on ae Zum Anzeigen von Diagrammdaten die im Speicher des Messger tes gesichert wurden wi
17. Messung Stromkreise mit 4 20 mA stellen einen analogen elektrischen bertragungsstandard f r industrielle Messger te und die Kommunikation dar In einem solchen Stromkreis entspricht ein Pegel von 4 mA 0 und ein Pegel von 20 mA 100 des Signals Die Nullposition bei 4 mA erlaubt den empfangenden Messger ten die Unterscheidung zwischen einem Nullsignal und einem unterbrochenen Draht oder fehlerhaften Ger t Die Vorteile der 4 20 mA bertragung die geringen Implementierungskosten sowie die M glichkeit viele Formen des elektrischen Rauschens auszuschlie en 1 Einstellungen und Verbinden der Pr fleitungen wie in Punkt 6 10 Gleichstrommessungen beschrieben durchf hren 3 Funktionswahlschalter in 4 20mA Position drehen 4 Der Schleifenstrom wird in in der LCD Anzeige wie folgt angegeben 0 mA 25 4 mA 0 20 mA 100 24 mA 125 36 6 Standardanzeige Auto range 06 32pm 0 0000 2 6 1 Diagramm Anzeige Dr cken Sie die Taste F1 GRAPH zum Umschalten in die grafische Messwertdarstellung Dr cken Sie die Taste F1 START Um eine schnelle oder langsame Abtastrate auszuw hlen dr cken Sie die Tasten F2 FAST oder F3 SLOW Dr cken Sie Taste F4 CANCEL um die grafische Messwertdarstellung zu verlassen und zum normalen Messbetrieb zur ckzukehren 37 Dr cken Sie die Taste F4 STOP um die Aufzeichnung anzuhalten
18. Peaklech Pr f und Messtechnik Spitzentechnologie die berzeugt PeakTech 3440 Bedienungsanleitung Operation Manual Grafikmultimeter Graphical Multimeter 1 Sicherheitshinweise Dieses Ger t erf llt die EU Bestimmungen 2004 108 EG elektromagnetische Kompatibilit t und 2006 95 EG Niederspannung entsprechend der Festlegung im Nachtrag 2004 22 EG CE Zeichen E berspannungskategorie III 1000V Uberspannungskategorie IV 600V Verschmutzungsgrad 2 CAT Signalebene Telekommunikation elektronische Ger te mit geringen transienten berspannungen CAT Il F r Hausger te Netzsteckdosen portable Instrumente etc CAT Ill Versorgung durch ein unterirdisches Kabel Festinstallierte Schalter Sicherungsautomaten Steckdosen oder Sch tze CAT IV Ger te und Einrichtungen welche z B ber Freileitungen versorgt werden und damit einer st rkeren Blitzbeeinflussung ausgesetzt sind Hierunter fallen z B Hauptschalter am Stromeingang Uberspannungsableiter Stromverbrauchsz hler und Rundsteuerempf nger Zur Betriebssicherheit des Ger tes und zur Vermeidung von schweren Verletzungen durch Strom oder Spannungs berschl ge bzw Kurzschl sse sind nachfolgend aufgef hrte Sicherheitshinweise zum Betrieb des Ger tes unbedingt zu beachten Sch den die durch Nichtbeachtung dieser Hinweise entstehen sind von Anspr chen jeglicher Art ausgeschlossen Dieses Ger t darf nicht in hochenergetischen Schal
19. TUP und anschlie end BLUETOOTH aus und best tigen Sie mit der Taste F1 ENTER Im LCD Display erscheint die Frage Turn off Bluetooth Dr cken Sie die Taste F1 OK um die Bluetooth Schnittstelle zu deaktivieren 50 9 Auswechseln des Akkus Ersetzen Sie die Batterien wie folgt 1 Schalten Sie das Messger t aus und entfernen Sie alle Messleitungen von den Eingangsbuchsen Drehen Sie die Schraube des Batteriefaches eine halbe Umdrehung gegen den Uhrzeigersinn um das Batteriefach zu ffnen Ersetzen Sie den 7 4 Volt Akku durch einen neuen gleicher Bauform Setzen Sie das Batteriefach wieder auf das Ger t und sichern Sie es durch Drehen der Schraube um eine halbe Umdrehung im Uhrzeigersinn 10 Aufladen des Li Ion Akkus 1 Stellen Sie den Funktionsschalter auf die OFF CHG Position 2 Stecken Sie den Ladeadapter in die Eingangsbuchsen des Messger tes und den AC Adapter mit dem Ladeadapter Verbinden Sie den AC Adapter mit der Steckdose 3 Auf der TFT LCD Anzeige erscheint ein Ladesymbol siehe Abbildung Adapter 52 11 Auswechseln der Sicherung Achtung Vor Abnahme des Batteriefachdeckels zum Auswechseln der Sicherungen Pr fleitungen von den Eing ngen des Multimeters abziehen und Ger t ausschalten Defekte Sicherung nur durch eine dem Originalwert entsprechende Sicherung ersetzen Zum Auswechseln der Sicherung wie beschrieben vorgehen 1 Drehen Si
20. WN zwischen den Men punkten Summer Beeper Numerisches Format Numeric Format Datumsformat Date Format und Uhrzeitformat Time Format ausw hlen Dr cken Sie die Taste F1 EDIT um den jeweiligen Men punkt einzustellen 47 Numerisches Format 0 0000 0 0000 Datumsformat MM DD YY DD MM YY Uhrzeitformat 12 Hour 24 Hour 7 4 Anzeige Datums und Zeiteinstellungen Auto range 08 32pm 9 m Display Set Date 06 02 14 dd mnvyy Set Time 08 29 00 pm Auto Power Off 00 O Foreground MB Background Select Font 0 ffnen Sie das Ger te Men durch Dr cken der Taste F3 SAVE Wahlen Sie mit der Taste F3 DOWN den Men punkt SETUP und anschlie end DISPLAY aus und best tigen Sie mit der Taste F1 ENTER Mit den Tasten F2 UP und F3 DOWN zwischen den Men punkten Datum Set Date Uhrzeit Set Time Abschaltautomatik Auto Power Off und LCD Farbeinstellung f r Messdaten bzw Hintergrundfarbe Foreground Background ausw hlen Dr cken Sie die Taste F1 EDIT um den jeweiligen Men punkt einzustellen 48 7 5 Abschaltautomatik Mit den Tasten F2 UP und F3 DOWN Abschaltautomatik Auto Power Off ausw hlen Dr cken Sie die Taste F1 EDIT um den jeweiligen Men punkt einzustellen 0 deaktiviert die Abschaltautomatik Dr cken Sie die Taste F1 OK um die ausgew hlte Zeit zu
21. ad into the negative COM jack and the red test lead into the positive V Q CAP Hz Temp jack 4 Touch the test leads to the capacitor to be tested The display will indicate the proper decimal point value and symbol 89 5 9 Temperature Measurement Warning To avoid electric shock disconnect both test probes from any source of voltage before making a temperature measurement 1 Set the function switch to TEMP C F position 2 Pres the push button F2 to select C or F 3 Insert the multi function adaptor in the input socket for V Q CAP Hz Temp and COM for temperature measurements 4 Insert the K type thermocouple into the multi function adaptor making sure to observe the correct polarity 5 Touch the temperature probe head to the part whose temperature you wish to measure Keeps the probe touching the part under test until the reading stabilizes about 30 seconds 6 Read the temperature in the display The digital reading will indicate the proper decimal point and value Warning To avoid electric shock be sure the thermocouple has been removed before changing to any other measurement function 90 5 10 DC Current Measurements Warning To avoid electric shock do not measure DC current on any circuit whose voltage exceeds 1000V DC ACrms Caution Do not make current measurements on the 10A scale for longer than 30 sec Exceeding 30 sec may cause damage to the meter and or t
22. ams Caution Do not make current measurements on the 10A scale for longer than 30 sec Exceeding 30 sec may cause damage to the meter and or the test leads 93 Insert the black test lead into the negative COM jack For current measurements up to 5000uA AC set the function switch to the A position and insert the red test lead into the HA mA jack For current measurements up to 500mA AC set the function switch to the mA position and insert the red test lead into the HA mA jack For current measurements up to 10A AC set the function switch to the 10A position and insert the red test lead into the 10A jack Press the F2 button MODE until AC appears in the display Remove power from the circuit under test and open the circuit at the point where you wish to measure current Touch the black test probe tip to the negative side of the circuit and touch the red test probe tip to the positive side of the circuit Apply power to the circuit Read the current in the display The display will indicate the proper decimal point value and symbol 94 5 12 4 20mA Measurements 4 20 mA circuits represent an analog electrical transmission standard for industrial instruments and the communication In such a circuit a level corresponding to 0 of 4 mA and 20 mA a level of 100 of the signal The zero position at 4 mA allows the receiving instrument to distinguish between a zero signal and a broken wire
23. ately on non sine wave or distorted signals True rms meters read accurately on either type of signal 50Hz 20000Hz OL is displayed 5 30minutes approximately with disable feature Automatic no indication for positive Minus sign for negative 20 times per second nominal 114 Low Battery Indication Battery Fuse Safety Dimensions WxHxD Weight Per is displayed if battery voltage drops below operating voltage 7 2 V NEDA 1604 battery mA pA ranges 0 8A 1000V 6 3x32mm ceramic fast blow A range 10A 1000V 10x328mm ceramic fast blow This meter is intended for origin of installation use and protected against the users by double insulation per EN61010 1 and IEC61010 1 2nd Edition 2001 to Category IV 600V and Category III 1000V Pollution Degree 2 The meter also meets UL 61010 1 2 Edition 2004 CAN CSA C22 2 No 61010 1 2 Edition 2004 and UL 61010B 2 031 1st Edition 2003 81x 175 x 53 mm 390 g 115 12 3 Specifications AC Voltage Range Resolution 50 60Hz lt 1kHz lt KH lt 20kHz un nn mm 10 5 30 5 5 dg 5dgt 20dgt 50 V 0001 vV 05 500 V oa vV 5d 35 notspeciied 1 5 10 10dgt 1000 V 01 V dg not notspeciied specified gt 10 of range DC Voltage Range Resolution Accuracy 500 mV 0 01 mV 0 1 5 dot 5 V 0 0001 V 0 05 5 dot 50 V 0 001 V 0 05 5 dot
24. bernehmen und dr cken Sie dann um das Men zu verlassen die Taste F4 CLOSE 7 6 Anzeige Vordergrund und Hintergrund Einstellungen Wahlen Sie den Men punkt Foreground and Background Vordergrund und Hintergrund und dr cken Sie die Taste F1 OK Dann nutzen Sie die Tasten F2 UP und F3 DOWN um die Farbe anzupassen Best tigen Sie die Einstellung mit der Taste Fi OK 7 7 Einstellen der Schriftart W hlen Sie den Men punkt SELECT FONT Schriftart ausw hlen und dr cken Sie die Taste F1 OK Dann nutzen Sie die Tasten F2 UP und F3 DOWN um die Schriftart anzupassen Best tigen Sie die Einstellung mit der Taste F1 OK 49 8 Bluetooth Sie k nnen die Bluetooth Kommunikationsverbindung nutzen um den Inhalt des internen Speichers dieses Messger ts an einen PC mit entsprechenden Empf nger zu bertragen ffnen Sie das Ger te Men durch Dr cken der Taste F3 SAVE Wahlen Sie mit der Taste F3 DOWN den Men punkt SETUP und anschlie end BLUETOOTH aus und best tigen Sie mit der Taste F1 ENTER Im LCD Display erscheint die Frage Turn on Bluetooth Dr cken Sie die Taste F1 OK um die Bluetooth Schnittstelle zu aktivieren Um die Bluetooth Schnittstelle wieder auszuschalten gehen Sie wie folgt vor ffnen Sie das Ger te Men durch Dr cken der Taste F3 SAVE Wahlen Sie mit der Taste F3 DOWN den Men punkt SE
25. ch Aufl sung Genauigkeit 200 1350 C 0 1 C 1 0 3 0 C 200 2462 F 0 1 F 1 0 5 4 F Temperatur 1 Spezifikation enth lt nicht den Messfehler des Typ K anschl geschlossenen Temperatursensors 2 Genauigkeit der angegebenen Spezifikation setzt eine Stabilit t der Umgebungstemperatur von 1 0 C voraus 5nF 0 001 nF 1 5 20 St 50 nF 0 01 nF 1 5 8 St 500 nF 0 1 nF 1 0 8 St 5 uF 0 001 uF 1 5 8 St 50 uF 0 01 uF 1 0 8St Kapazit t 500 uF 0 1 UF 15 8 St 10 mF 0 01 mF 2 5 20 St Mit einem Folienkondensator oder besser ist es sinnvoll die Relativwert Funktion REL A zu verwenden um die Anzeige auf null zu setzen Tastverh ltnis 0 1 99 90 0 01 1 2 v M 2 St Pulsweite 100 us 100ms Frequenz 5 Hz 150 kHz 58 Frequenz elektronisch 50 Hz 0 001 Hz 500 Hz 0 01 Hz 5 kHz 0 0001 kHz 3 50 kHz 0 001 kHz 001 5 St 500 kHz 0 01 kHz 5 MHz 0 0001 MHz 10 MHz 0 001 MHz Nicht spezifiziert Empfindlichkeit 2Ve minimum bei 20 80 Tastverh ltnis duty cycle und lt 100 kHz 5Ve minimum bei 20 80 Tastverh ltnis duty cycle und gt 100 kHz Frequenz elektrisch 10 Hz 10 kHz 0 01 Hz 0 001 kHz 0 5 vom Messwert Empfindlichkeit 2V ei Gleichstrom DCA 500 uA 0 01 pA 5000 uA 0 1 pA 0 2 5 St 50 mA 0 001 mA
26. currently selected range will be held 2 Press the RANGE button to step through the available ranges until you select the range you want 3 Press and hold the RANGE button for 2 seconds to exit the manual ranging mode and return to AUTO mode 69 4 Feature 4 1 Understanding the Push Buttons The 6 push buttons on the front of the Meter activate features that augment the function selected using the rotary switch navigate menus or control power to Meter circuits Fi F2 F3 F4 RANGE HOLD REL Software key Default switch to Graph measure Software key Default modes related to the rotary switch function Software key Default into save mode default Display And wake up for APO Software key Default modes MINMAX starts and stops MINMAX recording Into manual range and select range of the measure lf Pressing the Range button for greater that 1 second will return Auto Range Freezes the present reading in the display and allows the display to be saved If Pressing the HOLD REL button for greater that 1 second will switch relative mode 70 4 2 Understanding the Display aron oo NO oa a co to A TTD MUU TL TU LOU LU UN TL LLL 500 me o 100 300 S00mv me GRAPH MODE Soft key labels Indicates the function of the button just below the displayed label Bar graph Analog display of the input signal Minus sign indicates a negative reading Displays mea
27. e any interrupted problems of the equipments and watch on without person With this device it is easy to find and solve the problems of production equipments it is provided with Bluetooth technology and internal memory of the measurement values It provides a high standard of safety for each application of measurement This meter measures AC DC Voltage AC DC Current Resistance Capacitance Frequency electrical amp electronic Duty Cycle Diode Test Insulation Test Continuity and Thermocouple Temperature It can store and recall data It features a waterproof rugged design for heavy duty use 1 2 Input Limits Function Overload protection DCV ACV 1000V DC AC rms DCA ACA uA mA 800mA 1000V DCA ACA 10 A 10 A 1000V Resistance 1000V DC AC rms Diode Continuity 1000V DC AC rms Capacity 1000V DC AC rms Frequency 1000V DC AC rms Temperature 1000V DC AC rms 64 1 3 Safety Symbols Si A v amp T V GS approved T V Rheinland Attention Read the corresponding Section in the manual Failure to comply entails risk of injury and or the risk of damage to the device ar max allowable voltage difference of w 1000 V DC ACrms between COM V or ohm input and earth does not exceed for safety reasons Dangerous high voltage is applied between the inputs Extreme caution in the measurement Do not touch inputs and measuring tips Safety instructions in th
28. e beschrieben verfahren Taste F3 SAVE dr cken um in das System Men zu gelangen Mit der Taste F3 DOWN den Men punkt VIEWG ausw hlen Taste F1 ENTER dr cken um den Messwert zu speichern Dr cken der Taste F2 PREV oder F3 NEXT um durch die gespeicherten Daten zu bl ttern Durch Dr cken der Taste F1 ENTER kann der gespeicherte Messwert genauer betrachtet werden Durch Dr cken der Tasten F2 oder F3 kann der Verlauf des gespeicherten Diagramms betrachtet und die einzelnen Messwerte angezeigt werden 41 6 6 Messdaten aufzeichnen Auto range 06 32pm 366 55 Set Duration 00Days 00Hrs 01Min O Set Sample Interval 00Min 01Sec Dr cken Sie die Taste F3 SAVE Dann dr cken Sie die Taste F3 DOWN um den Men punkt RECORD auszuw hlen und bestatigen mit der Taste F1 ENTER a Zeitrahmen der Messung festlegen W hlen Sie nun mit den Tasten F3 DOWN den Men punkt Set Duration aus und best tigen mit der Taste Fi ENTER Hier k nnen Sie die Dauer der Messung einstellen Mit der Taste F2 erh hen Sie die Einstellung der einzelnen Stellen Stunde Minute Sekunde Mit der Taste F3 gt gt springen Sie zur n chsten Stelle Haben Sie die Eingabe beendet best tigen Sie diese mit der Taste F1 OK b Messinterval einstellen Dr cken Sie die Taste F3 DOWN um den n chsten Punkt Set Sample Interval Mess
29. e die Schraube des Batteriefaches eine halbe Umdrehung gegen den Uhrzeigersinn um das Batteriefach zu ffnen Die 4 Gehauseschrauben am Ger t l sen und Geh usser ckseite abnehmen Defekte Sicherung vorsichtig aus dem Sicherungshalter entfernen Neue im Wert und den Abmessungen der Originalsicherung entsprechende Sicherung in den Sicherungshalter einsetzen Darauf achten dass die Sicherung mittig im Halter sitzt Nach dem Auswechseln der entsprechenden Sicherung Geh user ckseite wieder auf Ger t auflegen und mit den 4 Schrauben befestigen danach Setzen Sie das Batteriefach wieder auf das Ger t und sichern Sie es durch Drehen der Schraube um eine halbe Umdrehung im Uhrzeigersinn 800mA 1000V F flink 6 3 x 32mm 10 A 1000V F flink 10 x 38 mm 53 12 Technische Daten 12 1 Allgemeine Daten Anzeige TFT LCD Anzeige mit einer maximalen Anzeige von 49999 Uberlastschutz in allen Bereichen Data Hold Relativ Maximal und Minimalmesswerthaltefunktion Automatische manuelle Bereichswahl Messwertspeicher 10 000 Messwerte Datenlogger Trendanzeige ca 20 000 Messwerte Betriebstemperaturbereich 5 40 C0 lt 80 RH Betriebsh he lt 2000 m Lagertemperaturbereich 20 60 C lt 80 RH Temperaturbereich f r angegebene Genauigkeit 18 28 C 11 2 Allgemeine technische Daten Gehause Doppelt geform wasserdicht Falltest 2m Dioden Test Teststrom von 0 9 mA maximal Leerlaufspannung 3 2 V DC typi
30. e function switch to the Q EL position 2 Insert the black test lead into the negative COM jack and the red test lead into the positive V Q CAP Hz Temp jack 3 Touch the test probe tips across the circuit or part under test It is best to disconnect one side of the part under test so the rest of the circuit will not interfere with the resistance reading 4 Read the resistance in the display The display will indicate the proper decimal point value and symbol Caution When you short the test leads in the 600 range your meter display a small value no more than 0 3 Q This value is due to your meter s and test leads internal resistance Make a note of this value and subtract it from small resistance measurements for better accuracy 85 5 6 Continuity Test Caution To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Remove the batteries and unplug the line cords 1 Set the function switch to the Q H caP position 2 Press the push button F2 to select the continuity test 3 Insert the black test lead into the negative COM jack and the red test lead into the positive V Q CAP Hz Temp jack 4 If the resistance is less than approximately 250 the audible signal will sound If the circuit is open the display will indicate OL 86 5 7 Diode Test The diode test feature allows the determination of
31. e the meter could be damaged Use caution when working with voltages above 35V DC or 25V AC These Voltages pose shock hazard Charge the battery as soon as the battery indicator BAT appears With a low battery the meter might produce false reading that can lead to electric shock and personal injury Fetch out the battery when the meter will not be used for long period Periodically wipe the cabinet with a damp cloth and mid detergent Do not use abrasives or solvents The meter is suitable for indoor use only Do not operate the meter before the cabinet has been closed and screwed safely as terminal can carry voltage Do not store the meter in a place of explosive inflammable substances Do not modify the equipment in any way Do not place the equipment face down on any table or work bench to prevent damaging the controls at the front Opening the equipment and service and repair work must only be performed by qualified service personnel Measuring instruments don t belong to children hands 63 Cleaning the cabinet Clean only with a damp soft cloth and a commercially available mild household cleanser Ensure that no water gets inside the equipment to prevent possible shorts and damage to the equipment 1 1 Introduction Professional True RMS Industrial Digital Multimeter and TFT color LCD display providing fast A D converting sampling time high accuracy built in datalogger and Trend Capture features It can trac
32. e user manual note Caution refer to the instruction manual Incorrect use may result in damage to the device or its components AC Alternating Current DC Direct Current AC or DC Earth ground Double insulated Fuse Conforms to European Union directives m fj SH I This WARNING CAUTION symbols indicate a Warning potentially hazardous situation which if not avoided may result in minor or moderate injury or damage to the product or other property Caution 65 2 Front Panel Description 66 TFT LCD display with a indication of max 50 000 Function keys F1 F2 F3 F4 to select and control the menu functions HOLD REL key data hold relative value measuring function Function Range switch To select the desired measurement function or the measuring range RANGE button Switch to manual range selection COM input jack Input jack for the black test lead for all measurement functions V Q Hz ll input jack input connector for red test lead for all measurement functions except current measurements uA mA input jack input socket for AC DC current measurements of lt 500mA 10A input jack input socket for AC DC current measurements of 500mA to 10A 67 3 Operating instructions Warning Risk of electrocution High voltage circuits both AC and DC are very dangerous and should be measured with great care 1 Always push the power switch to the OFF position when the
33. elles True RMS Digital Multimeter mit TFT Farb LCD Display und bietet einen A D Wandler mit einer schnellen Messrate hoher Genauigkeit integriertem Datenlogger und Trend Capture Funktionen Es k nnen alle m glichen Unterbrechungen an Ausr stungen oder Anlagen verfolgt beobachten und behoben werden Mit diesem Ger t sind Probleme an Produktionsanlagen Ausr stungen leicht zu finden und zu l sen Es ist mit einer Bluetooth Technologie und einem internen Speicher f r Messwerte ausgestattet und bietet einen hohen Sicherheitsstandard f r jegliche Messanwendung Dieses Messger t misst AC DC Spannung AC DC Strom Widerstand Kapazit t Frequenz elektrischen und elektronischen Arbeitszyklus Diodentest Isolationstes Durchgangs und Thermoelement Temperatur Es kann Daten speichern und wieder abrufen Es verf gt ber ein wasserdichtes robustes Design f r den harten Einsatz 1 2 Maximal zul ssige Eingangswerte Funktion berlastschutz DCV ACV 1000V DC AC eff DCA ACA uA mA 800mA 1000V DCA ACA 10 A 10 A 1000V Widerstand 1000V DC AC eff Diode Durchgang 1000V DC AC eff Kapazitat 1000V DC AC eff Frequenz 1000V DC AC eff Temperatur 1000V DC AC eff 1 3 Sicherheitssymbole und Hinweise am Ger t arD Ger t ist T V GS gepr ft T V Rheinland Achtung Entsprechende n Abschnitt e in der Bedien ungsanleitung nachlesen Nichtbeachtung birgt Verletzungsgefahr und
34. ery to make sure that they are still good and properly inserted 800mA 1000V F fast acting 6 3 x 32mm 10 A 1000V F fast acting 10 x 38 mm 112 12 Technical Data 12 1 Specifications Display Overload protection Data Hold Relative Mode MIN MAX Mode Auto manual Ranging Internal memory Operating Temperature Storage Temperature Altitude Accuracy temperature TFT LCD display with max display of 49999 on all ranges 10 000 measurement values Datalogger TREND approx 20 000 values 5 C to 40 C lt 80 RH 20 60 C lt 80 RH lt 2000 m 18 C 28 C 64 F to 82 F to maintain guaranteed accuracy 12 2 General Specifications Enclosure Shock Drop Test Diode Test Double molded waterproof 6 5 feet 2 meters Test current of 0 9mA maximum open circuit voltage 3 2V DC typical 113 Continuity Check PEAK Temperature Sensor Input Impedance AC Response AC True RMS ACV Bandwidth Overrange indication Auto Power Off Polarity Measurement Rate Audible signal will sound if the resistance is less than 25 approx test current lt 0 35mA Captures peaks gt 1ms Requires type K thermocouple gt 10MQ VDC amp gt 9MQ VAC True rms The term stands for Root Mean Square which represents the method of calculation of the voltage or current value Average responding multi meters are calibrated to read correctly only on sine waves and they will read inaccur
35. fleitung mit dem positiven V Q CAP Hz Temp Eingang 3 Dr cken Sie die F2 Taste auf dem Display um anzuzeigen AC DC 4 Lesen AC DC Messwert im Display Vaessc 0 0276 0 0000 V 0 0276 5 2 Spannungsmessung mV Achtung Vor dem Ein bzw Ausschalten der Messschaltung Pr fleitungen von der Messschaltung abziehen Hohe Einschaltstr me oder spannungen k nnten sonst u U das Messger t besch digen bzw zerst ren Achtung Phantomwerte In niedrigen DC und AC Spannungsbereichen und nicht angeschlossenen und somit offenen Eing ngen zeigt die LCD Anzeige sogenannte Phantomwerte d h nicht 000 an Dieses ist normal und stellt keinen Defekt des Ger tes dar 20 o l l Funktionswahlschalter in Stellung mV Mit der Taste F2 MODE die mV oder mV Funktion ausw hlen Rote Pr fleitung an den V Q CAP Hz Temp Eingang und die schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en Pr fleitungen ber die zu messendende Spannungsquelle anlegen und Messwert in der LCD Anzeige des Ger tes ablesen Bei negativen Messwerten erscheint ein Minussymbol links vom Messwert 21 5 3 Wechselspannungsmessung V AC Achtung Bei Messungen an 230V Steckdosen ist u erste Vorsicht geboten Die Messspitzen der Pr fleitungen sind u U f r einen einwandfreien Kontakt mit den Innenkontakten der Steckdose nicht lang genug und die LCD Anzeige zeigt daher 0 V obwohl ei
36. gen ber dem zu messenden Bauteil einmal ein Messwert und einmal das berlaufsymbol OL angezeigt ist die Diode in Ordnung Erscheint beim Anlegen bzw Vertauschen der Pr fleitungen in beiden F llen das Uberlaufsymbol ist die Diode offen Wird in beiden F llen ein sehr geringer Wert oder 0 angezeigt ist die Diode kurzgeschlossen Hinweis Der angezeigte Wert entspricht dem Spannungsabfall der Diode in Durchlassrichtung 29 5 8 Kapazit tsmessung Achtung Kapazit tsmessungen nur in spannungslosen Schaltungen durchf hren und Kondensator vor der Messung unbedingt entladen Kondensator zur Messung aus der Schaltung ausl ten Messung wie beschrieben durchf hren 1 Funktionswahlschalter in Stellung Q H CAP drehen 2 Taste F2 dr cken um die Kapazit tsmessfunktion auszuw hlen 3 Rote Pr fleitung an den V Q CAP Hz Temp Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 4 Pr fleitungen ber den zu messenden Kondensator anlegen Polarit t beachten 5 Messwert in der LCD Anzeige ablesen 30 5 9 Temperaturmessfunktion Achtung Temperaturmessungen nur an spannungsfreien Schaltungen bzw Messobjekten vornehmen Temperaturmessung wie beschrieben durchf hren 1 Funktionswahlschalter in Stellung TEMP C F drehen 2 Taste F2 um zwischen C und F auszuw hlen 3 Adapter f r Temperaturmessungen in Eingangsbuchsen V Q CAP Hz Temp
37. he test leads 91 10 According to the current to be measured rotate function selector switch to either position of uA mA or 10A Set the device to the DC measurement function DC by pressing the F2 key MODE In the LCD display the operation icon DC appears For current measurements up to 5000 uA DC set the function switch to the 4A position and insert the red test lead banana plug into the mA uA jack For current measurements up to 500 mA DC set the function switch to the mA position and insert the red test lead banana plug into the mA uA jack For current measurements up to 10 A DC set the function switch to the 10 A position and insert the red test lead banana plug into the 10 A jack For safety reasons in case of unknown current magnitudes always choose the 10A range and corresponding measured value display switch to a mA measurement range Remove power from the circuit under test and open the circuit at the point where you wish to measure current Ensure correct polarity Touch the black test probe tip to the negative side of the circuit and touch the red test probe tip to the positive side of the circuit Apply power to the circuit Read the current in the display The display will indicate the proper decimal point value and symbol 92 5 11 AC Current Measurements Warning To avoid electric shock do not measure AC current on any circuit whose voltage exceeds 1000V DC AC
38. ings with the push button F1 OK 7 7 Set Font W hlen Sie den Men punkt SELECT FONT Schriftart ausw hlen und dr cken Sie die Taste F1 OK Dann nutzen Sie die Tasten F2 UP und F3 DOWN um die Schriftart anzupassen Best tigen Sie die Einstellung mit der Taste F1 OK 108 8 Bluetooth You can use the Bluetooth communication link and transfer the contents of a meter s memory to a PC Open the setup menu Open the Save menu by pressing the push button F3 SAVE Press the push button F3 DOWN the menu item SETUP and then BLUETOOTH and press the push button F1 ENTER The LCD screen will be prompted Turn on Bluetooth Press the push button F1 OK to activate the Bluetooth interface To turn off the Bluetooth interface again proceed as follows Open the Devices menu by pressing the push button F3 SAVE Press the push button F3 DOWN the menu item SETUP and then BLUETOOTH and press the push button F1 ENTER The LCD screen will be prompted Turn off Bluetooth Press the push button F1 key OK to disable the Bluetooth interface 109 9 Replacing the battery Refer to Figure and replace the batteries as follows 1 2 3 Turn the Meter off and remove the test leads from the terminals Remove the battery door assembly by using a screwdriver to turn the battery door screw one half turn counterclockwise Replace the batteries with 7 4 volt cha
39. itsbestimmungen vornehmen Bei h heren Spannungen k nnen besonders gef hrliche Stromschl ge auftreten Laden Sie den Akku wieder auf sobald das Batteriesymbol BAT aufleuchtet Mangelnde Batterieleistung kann unpr zise Messergebnisse hervorrufen Stromschl ge und k rperliche Sch den k nnen die Folge sein Sollten Sie das Ger t f r einen l ngeren Zeitraum nicht benutzen entnehmen Sie die Batterie aus dem Batteriefach S ubern Sie das Geh use regelm ig mit einem feuchten Stofftuch und einem milden Reinigungsmittel Benutzen Sie keine tzenden Scheuermittel Dieses Ger t ist ausschlie lich f r Innenanwendungen geeignet Vermeiden Sie jegliche N he zu explosiven und entflammbaren Stoffen ffnen des Ger tes und Wartungs und Reparatur arbeiten d rfen nur von qualifizierten Service Technikern durchgef hrt werden Ger t nicht mit der Vorderseite auf die Werkbank oder Arbeitsfl che legen um Besch digung der Bedienelemente zu vermeiden Keine technischen Ver nderungen am Ger t vornehmen Messger te geh ren nicht in Kinderh nde Reinigung des Ger tes Ger t nur mit einem feuchten fusselfreien Tuch reinigen Nur handels bliche Sp lmittel verwenden Beim Reinigen unbedingt darauf achten dass keine Fl ssigkeit in das Innere des Ger tes gelangt Dies k nnte zu einem Kurzschluss und zur Zerst rung des Ger tes f hren 1 1 Einleitung Das PeakTech 3440 ist ein profession
40. meric Format 0 0000 0 0000 Date Format MM DD YY DD MM YY Time Format 12 Hour 24 Hour 7 4 Setting Display Date and Time Auto range 08 32pm o o mi Display Set Date 06 02 14 dd imm yy O Set Time 08 29 00 pm O Auto Power Off 00 O Foreground Background Select Font 0 Open the Save menu by pressing the push button F3 SAVE Press the push button F3 DOWN to select the menu item SETUP and after that DISPLAY and press the push button F1 ENTER to confirm With the push buttons F2 UP and F3 DOWN choose between the menu items Set Date Set Time Auto Power Off and LCD color adjustment for measured data and background color Foreground Background Press the push button F1 EDIT to select the respective menu item 107 7 5 Auto Power Off With the push buttons F2 UP and F3 DOWN choose Auto Power Off Press the F1 key EDIT to select the respective menu item To adjust the automatic power off function to one of the preset values using F2 UP or F3 DOWN 0 disables the auto power off Press the F1 key OK to accept the selected time and then press the push button F4 CLOSE to exit the menu 7 6 Display Foreground and Background Adjustments Choose the menu item Foreground and Background and press the push button F1 OK Then use the push buttons F2 UP and F3 DOWN to adjust the color Confirm your sett
41. n Press the push button F4 PMAX again to activate the peak hold function PEAK 75 4 7 Relative Measurement 0 0430 Reference 0 3079 V V Press the REL key you can measure the relative value and REL sign will appear on the LCD display in the relative mode What is meant by the relative value Press the REL key the meter make the first measured value into a reference value You must be decide a reference value as the input signal and the meter store the displayed reading as a reference value The relative measured value that displayed in LCD is achieved by subtracting a reference value from the present reading value Vx Vref Vdisplay In it Vx measured value Vref reference value Vdisp displayed value To activate the relative mode press and hold the HOLD REL button for greater than 2 seconds 76 4 8 DATA HOLD To freeze the display for any function press key HOLD Press key save to memory And press close return measure To save the measured value held in the internal memory press the F3 key SAVE To exit the data hold mode press the F4 key CLOSE 77 5 Messbetrieb 5 1 DC Voltage measurements l 4 o i ji o 1 Set the function switch to the green position 2 Press F2 button MODE to select V function 3 Insert the black test lead into the negative COM jack Insert the red test lead into the positive V Q CAP Hz Temp
42. nd Modifikatoren Ausgew hlte Tastenoptionen werden nicht auf andere Messfunktionen bertragen V Spannungsmessfunktion AC V Spannungsmessfunktion DC und AC DC mV DC AC milli Volts Messfunktion Q gt gt 7 CAP Widerstand Diodentest Kapazitat und Durchgangspr ffunktion Hz Frequenzmessfunktion TEMP Temperatur Messfunktion A AC DC Strommessfunktion mA AC DC mA Strommessfunktion 4 20 MA 4 20mA Messfunktion pA AC DC pA AStrommessfunktionup to 5 000 pA 18 4 4 Verwenden der Eingangsbuchsen F r alle Funktionen au er der Strommessfunktion werden die V Q CAP Hz Temp und COM Eingangsanschl sse verwendet swetoorn vacar Ham TEMP Eingang f r 0 A bis 10 00 A Strom 20 10A VA berlast f r 30 Sekunden ein 10 Minuten aus Eingang f r 0 A bis 500 mA KAMM Strommessungen COM Masse Anschluss f r alle Messungen Eingang f r Spannung Kontinuit t vroarmmd f Hz CAP TEMP Widerstand Diodentest Frequenz Kapazit t und Temperatur 14 4 5 Erfassung von Minimal und Maximalwerten 08 12pm MAX MIN 0 2660 0 3493 V ea 0 2636 V MIN 0 2548 V Um den MAX MIN Modus zu aktivieren dr cken Sie die Taste F4 max min im normalen Messbetrieb Wie in Abbildung gezeigt zeigt das Messger t im oberen der Messwerteseite MAX MIN Dar ber hinaus erscheinen die aufgezeichneten Maximum
43. ne Spannung von 230 V an der Steckdose anliegt Daher immer sicherstellen dass ein einwandfreier Kontakt zwischen den Messspitzen den Pr fleitungen und den Innenkontakten der Steckdose besteht und nicht blind der 0 V Anzeige vertrauen Wichtig Vor dem Ein bzw Ausschalten der Messschaltung Pr fleitungen von der Messschaltung abziehen Hohe Einschaltstr me oder spannungen k nnten sonst u U das Messger t besch digen bzw zerst ren 29 Zur Messung von Wechselspannungen wie beschrieben verfahren 1 Funktionswahlschalter in Stellung V drehen 2 Taste F2 MODE dr cken um AC auszuw hlen 3 Rote Pr fleitung an den V Q CAP Hz Temp Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 4 Pr fleitungen ber die zu messende Spannungsquelle anlegen und Messwert in der LCD Anzeige des Ger tes ablesen 23 5 4 Frequenzmessung Zur Messung wie beschrieben verfahren 1 Funktionswahlschalter in Stellung Hz drehen 2 Rote Pr fleitung an den V Q CAP Hz Temp Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 3 Pr fleitungen ber das zu messende Bauteil bzw die zu messende Schaltung anlegen 4 Messwert in der LCD Anzeige ablesen Der Messwert wird in der entsprechenden Ma einheit Hz kHz MHz angezeigt 24 5 5 Widerstandsmessung Achtung Nach Umschaltung des Multimeters auf die Widerstandmessfunktion angeschlossene P
44. oder die Gefahr der Besch digung des Ger tes max zul ssige Spannungsdifferenz von 1000 V DC ACeff zwischen COM V bzw Ohm Eingang und Erde aus Sicherheitsgr nden nicht berschreiten Gefahrlich hohe Spannung zwischen den Eingangen Extreme Vorsicht bei der Messung Eingange und Messspitzen nicht ber hren Sicherheitshinweise in der Bedienungsanleitung beachten Wechselspannung Strom AC Gleichspannung Strom DC AC oder DC Erde Sicherung a El Doppelt isoliert ce Entspricht den Richtlinien der europ ischen Union Achtung M gliche Gefahrenquelle Sicherheitsvorschriften unbedingt beachten Bei Nichtbeachtung besteht u U Verletzungs oder Lebensgefahr und oder die Gefahr der Besch digung des Ger tes 2 Bedienelemente und Anschl sse am Ger t TFT LCD Display mit einer Anzeige von max 50 000 Funktionstasten F1 F2 F3 F4 zur Auswahl und Steuerung ber Men funktionen HOLD REL Taste Messwerthaltefunktion Relativwert messfunktion Funktions Bereichswahlschalter Zur Auswahl der gew nschten Messfunktion bzw des Messbereiches RANGE Taste Umschaltung auf manuelle Bereichswahl COM Eingangsbuchse Eingangsbuchse f r die schwarze Pr fleitung f r alle Messfunktionen V Q Hz I gt Eingangsbuchse Eingangsbuchse f r rote Pr fleitung f r alle Messfunktionen ausgenommen Strommessungen HA mA Eingangsbuchse Eingangsbuchse f r AC DC Strommessungen von lt 500m
45. or faulty appliance The advantage of the 4 20 mA transmission are low implementation costs and the possibility of excluding many forms of electrical noise 1 Set up and connect as described for DC mA measurements 2 Set the rotary function switch to the 4 20mA position 3 The meter will display loop current in as follows OmA 25 4mA 0 20 mA 100 24 mA 125 95 6 Default Display Auto range 06 32pm 0 0000 6 1 Graph Measure Press the push button F1 GRAPH to switch into the Graph measurement 06 32pm Press soft key F1 START button Press F2 FAST or F3 SLOW push buttons to select sampling rate Press F4 CANCEL push button to exit the graphical measurement and return to normal measurement mode 96 Press the push button F1 SAVE to save the graphic recording Press the push button F4 BACK to return to the normal measurement mode 97 6 2 Save Function 4 all Record Delete Setup SA find 5 In all measurement function it is possible by pressing F3 SAVE to enter the system menu 6 3 Storing Individual Measurement Data Follow the described procedure for storing a current measured value e Press the F3 push button SAVE to enter the system menu e Select the menu item SAVE by pressing the push button F3 DOWN e Press the push button F1 ENTER to save the measured value
46. r fleitungen nicht ber eine Spannungsquelle anlegen Widerstandsmessungen nur an spannungsfreien Schaltungen bzw Bauteilen vornehmen und Netzstecker aus der Steckdose ziehen In der Schaltung befindliche Kondensatoren vor der Messung unbedingt entladen 25 Zur Messung wie beschrieben verfahren 1 Funktionswahlschalter in Stellung Q 1 gt 2 drehen 2 Rote Pr fleitung an den V Q CAP Hz Temp Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 3 Pr fleitungen ber den zu messenden Widerstand anlegen 4 Messwert in der LCD Anzeige ablesen Hinweis Der Eigenwiderstand der Pr fleitungen kann bei Messungen von kleinen Widerst nden 600 Ohm Bereich die Genauigkeit der Messung negativ beeintr chtigen Der Eigenwiderstand blicher Pr fleitungen liegt zwischen 0 2 1 Ohm Zur exakten Bestimmung des Eigenwiderstandes Pr fleitungen an die Eingangsbuchsen des Multimeters anschlie en und Messspitzen kurzschlieBen Der angezeigte Messwert entspricht dem Eigenwiderstand der Pr fleitungen 26 5 6 Durchgangspr ffunktion Achtung Nach Umschaltung des Multimeters auf die Widerstandmessfunktion angeschlossene Pr fleitungen nicht ber eine Spannungsquelle anlegen Durchgangspr fungen nur an spannungsfreien Schaltungen bzw Bauteilen vornehmen und Netzstecker aus der Steckdose ziehen In der Schaltung befindliche Kondensatoren vor der Messung unbedingt entladen Zur Messung
47. r RANGE Taste wird der manuelle Messbereich in der aktuellen Messfunktion gew hlt Wird die RANGE Taste 2 Sekunden gedr ckt gehalten kehrt das Ger t wieder in die automatische Bereichswahl zur ck Durch Dr cken der HOLD REL Taste wird der aktuell angezeigte Messwert im Display eingefroren Wir die HOLD REL Taste 2 Sekunden gedr ckt gehalten wechselt das Ger t in die Relativwertmessfunktion 11 4 2 Funktionsweise der Anzeige 6 7 5 ie 06 32pm i H g j mV 04 2 UT TUT UD nag UY TUT l GRAPH MODE SAVE MAX Zuordnung der Drucktasten zeigt die Funktion der Drucktaste direkt unterhalb der angezeigten Markierung Analoge Balkengrafik Tendenzanzeige Anzeige der Polarit t des Eingangssignals bedeutet negative Polarit t Anzeige des aktuellen Messwertes Anzeige der Bereichswahl automatische Bereichswahl oder manuelle Bereichswahl Anzeige der Uhrzeit Batteriezustandsanzeige gibt den momentanen Ladezustand des Akkus an Symbol f r den akustischen Signalton zeigt an dass der akustische Signalton des Messger tes aktiviert ist nicht mit der Durchgangspr ffunktion verbunden Ma einheiten der gew hlten Messfunktion 12 4 3 Funktionsweise des Drehwahlschalters W hlen Sie eine prim re Messfunktion indem Sie den Drehschalter auf eine der m glichen Funktionen drehen Das Messger t stellt f r jede einzelne Messfunktion eine Standardanzeige Messbereich Ma einheiten u
48. rate einzustellen und best tigen durch Dr cken der Taste F1 ENTER Mit der Taste F2 erh hen Sie die Einstellung der einzelnen Stellen Minute Sekunde Mit der Taste F3 gt gt springen Sie zur n chsten Stelle Haben Sie die Eingabe beendet best tigen Sie diese mit der Taste F1 OK 42 c Aufnahme starten Dr cken Sie die Taste F1 ENTER um die Aufnahme zu starten Die Aufnahme Session wird so lange ausgef hrt bis der interne Speicher ersch pft ist die Versorgungsspannung der Batterie ungen gend ist der Funktionswahlschalter auf eine andere Messfunktion gedreht wird oder mit der Taste F4 STOP die Messung beendet wird 6 7 Anzeigen von Trenddaten Die aufgezeichneten Messdaten welche im internen Speicher des Messger tes abgelegt werden k nnen zu einem sp teren Zeitpunkt wieder angesehen werden Das Anzeigen dieser Daten wird durch das Ger te Men durchgef hrt Durch dr cken der Taste F3 SAVE ffnet sich das Speichermen des Ger tes Taste F3 DOWN dr cken bis der Men punkt VIEWR ausgew hlt ist und mit Taste F1 ENTER best tigen 08 27pm Recording mV 351 44 Start Times 06 02 14 08 26 09pm Duration O0days OOhrs OOmin 37sec Samples 37 Riog0002 Taste F1 TREND dr cken um in die Verlaufsanzeige der gespeicherten Messwerte zu gelangen 43 Taste F2 dr cken um die Aufl
49. rge batteries Observe proper polarity Reinstall the battery door assembly and secure it by turning the screw one half turn clockwise 110 10 Charge of Li Ion Battery 1 Set the function switch to the OFF CHG position 2 Insert the socket into the Meter Input terminals and the AC Adapter connected to the switch socket Then Insert the Adapter into Power socket 3 On TFT LCD display a charge symbol will appear Adapter 111 11 Replacing the fuses Warning To avoid electric shock disconnect the test leads from any source of voltage before removing the back cover or the battery fuse door 1 Turn the screw on the battery compartment half a turn counter clockwise to open the battery compartment 2 Remove the 4 housing screws of the device and remove the back cover 3 Remove the blown fuse from the fuse holder 4 Insert the new fuse into the fuse holder appropriate to the value and the dimensions of the original fuse Make sure that the fuse is centred in the holder 5 After replacing the appropriate backup Back cover replace it again on unit and secure it with the four screws then Replace the battery cover back onto the device and secure it by turning the screw by half a turn clockwise Warning To avoid electric shock do not operate your meter until the back cover and the battery door is in place and fastened securely Note If your meter does not work properly check the fuses and batt
50. rten Referenzwert REL Taste 1 x dr cken Der angezeigte Messwert wird auf 0 gesetzt Bei einem Referenzwert von 100 V z B und einem tats chlichen Messwert von 90 V wird in der LCD Anzeige 010 0 V angezeigt Sind Referenzwert und Messwert identisch zeigt die digitale Anzeige den Wert 0 Um die Relativwertmessfunktion zu aktivieren dr cken und halten Sie die HOLD REL Taste f r 2 Sekunden gedr ckt 17 4 8 Messwerthaltefunktion Data Hold Dr cken Sie die HOLD REL Taste um den momentanen Messwert in der LCD Anzeige einzufrieren und diesen unter g nstigeren Bedingungen abzulesen Um den gehaltenen Messwert im internen Speicher zu sichern dr cken Sie die Taste F3 SAVE Zum Verlassen des DATA HOLD Modus Taste F4 CLOSE dr cken 18 5 Messbetrieb 5 1 Gleichspannungsmessungen V DC 1 Funktionswahlschalter in Stellung V 2 Mit der Taste F2 MODE die V Funktion ausw hlen 3 Rote Pr fleitung an den V Q CAP Hz Temp Eingang und die schwarze Prifleitung an den COM Eingang des Ger tes anschlie en 4 Pr fleitungen ber die zu messendende Spannungsquelle anlegen und Messwert in der LCD Anzeige des Ger tes ablesen Bei negativen Messwerten erscheint ein Minussymbol links vom Messwert 19 5 1 1 AC DC 1 Stellen Sie den Funktionsschalter auf die Position V 2 Verbinden Sie die schwarze Pr fleitung mit dem negativen COM Eingang Verbinden Sie die rote Pr
51. sch 54 Durchgangspr ffunktion PEAK Funktion Temperatursensor Eingangswiderstand AC Ansprechverhalten AC Echteffektiv True RMS ACV Frequenz Bandbreite Uberbereichsanzeige Abschaltautomatik Polaritatsanzeige Messrate Akustisches Signal ert nt wenn der Widerstand geringer als 25 ca Teststrom lt 0 35mA Spitzenwerterfassung gt 1ms Ben tigt Typ K Temperaturf hler gt 10MQ VDC amp gt 9MQ VAC Echteffektiv True RMS Der Begriff steht f r Root Mean Square reprasentiert die Berechnungsmethode der Spannungs oder Stromwerte Durchschnittliche Multimeter sind so kalibriert um Sinuswellen korrekt anzuzeigen jedoch zeigen diese Nicht Sinussignale oder verzerrte Signale ungenau an Ger te mit Echteffektiv Funktion True RMS k nnen auch diese Signaltypen genau anzeigen 50Hz to 20000Hz OL wird angezeigt 5 30 Minuten und deaktivierbar Automatisch keine Anzeige f r positive Signale Minus Zeichen f r negativ 20 x pro Sekunde nominal 55 Batteriezustandsanzeige Batterie Akku Sicherungen Sicherheit Abmessungen BxHxT Gewicht Eee wird angezeigt wenn die Batteriespannung unter die ben tigte Betriebsspannung f llt 7 2 Volt NEDA 1604 Akku mA uA 0 8A 1000V 6 3x32mm flinke Keramiksicherung A Bereich 10A 1000V 10x328mm flinke Keramiksicherung Dieses Ger t ist f r Messungen an Elektro Installation konzipiert und gesch tzt d
52. sung der grafischen Anzeige zu erh hen Taste F3 gt gt dr cken um den Cursor zu bewegen Taste F4 BACK dr cken um die Funktion der Verlaufsanzeige zu verlassen 44 6 8 Hilfe Das Ger t verf gt ber eine intern gespeicherte Hilfefunktion die es dem Anwender erm glicht auch ohne Bedienungsanleitung Hinweise zur Handhabung von einzelnen Funktionen einzusehen Die Hilfe Funktion ist ber das Ger te Men abrufbar Taste F3 SAVE dr cken um das Ger te Men aufzurufen Taste F3 DOWN dr cken bis das Symbol INFO ausgew hlt ist und mit Taste F1 ENTER best tigen 08 20pm no Graph According to graphically display measurement information no Mode Releted to the rotary switch function Fno Save Accesses the memory management menu for saving measurement setting up recording sessions or viewing and deleting stored measurements from memory Mit den Tasten F2 und F3 kann innerhalb der Hilfe vor oder zur ckgebl ttert werden Um wieder in das Ger te Men zu gelangen Taste F4 CLOSE dr cken 45 7 Einstellungen Alle Einstellungen f r das Ger t k nnen ber das Ger te Men durchgef hrt werden Auto range 14 20 Display Meter Into Info rete ee Ss Ss Mit Taste F3 DOWN den Men punkt SETUP ausw hlen und mit Taste F1 ENTER best tigen 7 1 Gerat zuriicksetzen
53. surement information about the input signal Indicates the range the Meter is in and the ranging mode auto or manual Time Indicates the time set in the internal clock Battery level Indicates the charge level batteries Beeper Indicates the Meter s beeper is enabled not associated with the continuity beeper Units Indicates the units of measure 71 4 3 Understanding the Rotary Switch Select a primary measurement function by positioning the rotary switch to one of the icons around its perimeter For each function the Meter presents a standard display for that function range measurement units and modifiers Button choices made in one function do not carry over into another function V AC voltage measurements V DC and AC DC voltage measurements mV DC AC milli volts measurements Q gt CAP Resistance Diode test capacitance and continuity measurements Hz Frequency measurements TEMP Temperature measurements A AC DC amps measurements mA AC DC milliamps measurements 4 20 MA 4 20mA measurements uA AC DC microampere measurements up to 5 000 pA 72 4 4 Using the Input Terminals All functions except the current measurement function use the V Q CAP Hz Temp and COM input terminals ce On VQCAP Haw TEMP Input for 0 A to 10 00 A current 20VA 10 overload for 30 seconds on 10 minutes off AmA Input for O A to 500 mA curren
54. t H measurements COM Ground terminal for all measurements V Q gt t Hz CAP TEMP Input for voltage continuity resistance diode test frequency capacitance and temperature 73 4 5 Capturing Minimum and Maximum Values 06 12pm MAX MIN 0 2660 0 3493 V 0 2636 v To activate the MAX MIN mode press the push button F4 MAX MIN at measurement mode As shown in Figure the Meter displays at the top of the measurement page MAX MIN In addition the recorded maximum average and minimum values appear in the secondary display with their respective elapsed times To stop a MIN MAX recording session press the Softkey labeled F2 STOP The summary information in the display freezes and the softkeys change function to allow saving the collected data Pressing the softkey labeled F4 Close exits the MIN MAX record session without saving the collected data To save the MIN MAX screen data the MIN MAX session must be ended by pressing the softkey labeled F2 Stop Next press the softkey labeled F3 Save 74 4 6 Capturing Peak Values 08 12pm 0 2676 0 6354 v Piense 0 263 v PMIN 0 58694 y Using the function switch to select voltage or current measurement function Press the F2 push button MODE until the icon AC appears in the LCD display Pressing the F4 MAX push button to select the MAX HOLD functio
55. the usability of diodes and other semiconductor elements defined in circuits as well as the determination of the continuity short circuit and the voltage drop in the forward direction Warning To avoid electric shock do not test any diode that has voltage on it 87 1 Set the function switch to Q gt H CAP position 2 Press the F2 button until the PL symbol appears in the display 3 Insert the black test lead into the negative COM jack and the red test lead banana plug into the positive V Q CAP Hz Temp jack 4 Touch the test probe tips to the diode or semiconductor junction you wish to test Note the meter reading 5 Reverse the probe polarity by switching probe position Note this reading 6 The diode or junction can be evaluated as follows A If one reading shows a value and the other reading shows OL the diode is good B If both readings are OL the device is open C If both readings are very small or 0 the device is shorted Note The value indicated in the display during the diode check is the forward voltage 88 5 8 Capacitance Warning To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any capacitance measurements Remove the batteries and unplug the line cords 1 Set the function switch to the Q CAP position 2 Press the F2 button until the CAP symbol appears in the display 3 Insert the black test le
56. tlets portable equipment CAT Ill Supplied from a cable under earth fixed installed switches automatic cut off or main plugs CAT IV Units and installations which are supplied overhead lines which are stand in a risk of persuade of a lightning i e main switches on current input overvoltage diverter current use counter To ensure safe operation of the equipment and eliminate the danger of serious injury due to short circuits arcing the following safety precautions must be observed Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever Do not use this instrument for high energy industrial installation measurement Do not place the equipment on damp or wet surfaces x Do not exceed the maximum permissible input ratings danger of serious injury and or destruction of the equipment 61 The meter is designed to withstand the stated max voltages If it is not possible to exclude without that impulses transients disturbance or for other reasons these voltages are exceeded a suitable presale 10 1 must be used Replace a defective fuse only with a fuse of the original rating Never short circuit fuse or fuse holding Disconnect test leads or probe from the measuring circuit before switching modes or functions Do not conduct voltage measurements with the test leads connected to the uA mA A and COM terminal of the equipment The 10A range is protected by f
57. tung von automatischer auf manuelle Bereichswahl Beim Einschalten des Ger tes wird immer die automatische Bereichswahl aktiviert Die automatische Bereichswahl erleichtert den Messbetrieb und garantiert optimale Messergebnisse Zur Umschaltung auf manuelle Bereichswahl wie beschrieben verfahren 1 Taste RANGE dr cken Beim Dr cken der Taste erlischt die Anzeige AUTO und der zuletzt gew hlte Bereich bleibt weiterhin aktiviert 2 Taste RANGE ggf mehrmals bis zum Erhalt des gew nschten Bereiches dr cken 3 Zur R ckkehr zu automatischer Bereichswahl Taste RANGE f r ca 2 Sekunden gedr ckt halten Die Anzeige f r automatische Bereichswahl AUTO leuchtet auf 10 4 Merkmale 4 1 Erkl rung der Drucktaster en Fo LY a Gate ey as er CHE gt ta Die 6 Drucktasten auf der Frontplatte des Multimeters aktivieren Funktionen die die Messfunktionen welche ber den Drehschalter ausgew hlt wurden erweitern Mit den Tastern kann nun innerhalb der Men s navigiert werden Fi F2 F3 F4 RANGE HOLD REL Standardschalter auf Graph Messung Standard Funktion bezogen auf die jeweils gew hlte Messfunktion Standardeinstellung f r den Speicher Modus und Voreinstellung der Anzeige in allen Messfunktionen sowie wiedereinschalten nachdem die Abschaltautomatik das Ger t abgeschaltet hat MIN MAX startet und stoppt die Minimalwert Maximalwertmessfunktion Durch dr cken de
58. tungen verwendet werden Ger t nicht auf feuchten oder nassen Untergrund stellen Keine Fl ssigkeiten auf dem Ger t abstellen Kurzschlussgefahr beim Umkippen des Ger tes afe Ger t nicht in der N he starker magnetischer Felder Motoren Transformatoren usw betreiben maximal zul ssige Eingangsspannung von 1000V DC AC nicht berschreiten maximal zul ssige Eingangswerte unter keinen Umst nden berschreiten schwere Verletzungsgefahr und oder Zerst rung des Ger tes Die angegebenen maximalen Eingangsspannungen d rfen nicht berschritten werden Falls nicht zweifelsfrei ausgeschlossen werden kann dass diese Spannungsspitzen durch den Einfluss von transienten St rungen oder aus anderen Gr nden berschritten werden muss die Messspannung entsprechend 10 1 vorged mpft werden Nehmen Sie das Ger t nie in Betrieb wenn es nicht v llig geschlossen ist Defekte Sicherungen nur mit einer dem Originalwert entsprechenden Sicherung ersetzen Sicherung oder Sicherungshalter niemals kurzschlie en Vor dem Umschalten auf eine andere Messfunktion Pr fleitungen oder Tastkopf von der Messschaltung abkoppeln Keine Spannungsquellen ber die HA mA 10A und COM Eing nge anlegen Bei Nichtbeachtung droht Verletzungsgefahr und oder die Gefahr der Besch digung des Multimeters Der 10A Bereich ist durch eine 10A 1000V Sicherung abgesichert Bei der Widerstandsmessungen keine Spannungen anlegen Keine Strommessungen im
59. und COM einstecken 4 Typ K Temperaturf hler auf den Temperaturadapter anschlie en auf korrekte Polarit t achten 5 Messf hler auf die Oberfl che des zu messenden Bauteils aufsetzen und Kontakt bis zur Stabilisierung der Messwertanzeige aufrechterhalten ca 30 Sekunden 6 Temperaturwert nach erfolgter Stabilisierung in der LCD Anzeige ablesen 31 Achtung Aus Sicherheitsgr nden Temperaturf hler unbedingt vor dem Umschalten auf eine andere Messfunktion von den Eingangsbuchsen des Multimeters abziehen 5 10 Gleichstrommessungen Achtung Aus Sicherheitsgr nden keine Strommessungen in Schaltungen mit Spannungen von mehr als 1000V vornehmen Achtung Gleichstrommessungen von 10A auf maximal 30 Sekunden beschr nken 32 Entsprechend der zu messenden Stromgr e Funktionswahlschalter entweder in Stellung uA mA oder 10A drehen Ger t auf die Gleichstrommessfunktion DC durch Dr cken der Taste F2 MODE umschalten In der LCD Anzeige leuchtet das Funktionssymbol DC auf Abh ngig von der zu messenden Stromst rke rote Pr fleitung an den uA mA oder den 10A Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en Bei unbekannter Stromgr e aus Sicherheitsgr nden den 10A Bereich w hlen und bei entsprechender Messwertanzeige ggf auf einen mA Messbereich umschalten Zu messende Schaltung spannungslos schalten und am gew nschten Messpunkt ffnen
60. urch doppelte Isolierung entsprechend EN 61010 1 2010 und IEC 61010 1 2010 und berspannungskategorie CAT IV 600 V und CAT III 1000 V Verschmutzungsgrad 2 Es erf llt auch die UL 61010 1 2 Ausgabe 2004 CAN CSA C22 2 Nr 61010 1 2 Ausgabe 2004 und UL 61010B 2 031 1 Auflage 2003 81x 175 x53 mm 390 g 56 12 3 Spezifikationen Wechselspannung ACV Bereich Auf sung 50 60Hz lt 1kHz lt KkH lt 20kHz 500mV 001 mV 5 5 5 V 0 0001 V 1 0 45 30 5 ee 5 V 0001 V 500 V 001 V 05 6 435 110 Not 15 H0 Se mul 1000 V 01 V Nicht Nicht i i gt 10 des Messbereiches Gleichspannung DCV Bereich Aufl sung Genauigkeit 500 mV 0 01 mV 0 1 5St 5 V 0 0001 V 50 V 0 001 V 0 05 5 St 500 V 0 01 V 1000 V 0 1 V 0 1 5St Bei Verwendung der relaiv Modus REL Q zum Ausgleich des Offsets Gleichspannung AC DC Bereich Aufl sung lt 1kHz lt 5kHz 5V 0 0001 V 50 V 0 001 V 5 500 V 0 01 V t 1 2 20 St 3 0 20 St 1000 V 0 1 V 57 Bereich Aufl sung Genauigkeit 50 Q 0 01 Q 0 2 10 St 5 kQ 0 0001 kQ A Widerstand 2 50 ka 0001 ko re 500 kQ 0 01 KQ 5 5 MQ 0 0001Ma_ 05 5St 50 MQ 0 001 MQ 2 0 10 St Bei Verwendung der relativ Modus REL Q zum Ausgleich des Offsets Berei
61. use 10A 1000V To avoid electric shock disconnect power to the unit under test and discharge all capacitors before taking any resistance measurements Do not conduct current measurements with the leads connected to the V Q terminals of the equipment Check test leads and probes for faulty insulation or bare wires before connection to the equipment Please use only 4mm safety test leads to ensure immaculate function To avoid electric shock do not operate this product in wet or damp conditions Conduct measuring works only in dry clothing and rubber shoes i e on isolating mats Never touch the tips of the test leads or probe Comply with the warning labels and other info on the equipment The measurement instrument is not to be to operated unattended Always start with the highest measuring range when measuring unknown values Do not subject the equipment to direct sunlight or extreme temperatures humidity or dampness 62 Do not subject the equipment to shocks or strong vibrations Do not operate the equipment near strong magnetic fields motors transformers etc Keep hot soldering irons or guns away from the equipment Allow the equipment to stabilize at room temperature before taking up measurement important for exact measurements Do not input values over the maximum range of each measurement to avoid damages of the meter Do not turn the rotary function switch during voltage or current measurement otherwis
62. wie beschrieben verfahren 1 Funktionswahlschalter in Stellung O H cap drehen 2 Taste F2 dr cken um die Durchgangspr ffunktion auszuw hlen 3 Rote Pr fleitung an den V Q CAP Hz Temp Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 4 Wenn der Widerstand unter ca 250 liegt ert nt das akustische Signal Ist der Stromkreis offen wird das Display OL anzeigen 27 5 7 Diodenpr ffunktion Die Diodentestfunktion erm glicht die Bestimmung der Verwendbarkeit von Dioden und anderen Halbleiter Elementen in definierten Schaltungen sowie die Bestimmung der Durchg ngigkeit Kurzschluss und des Spannungsabfalls in Durchlassrichtung Achtung Vor berpr fung der Diode Bauteil bzw Schaltung unbedingt spannungslos schalten oder Diode aus der Schaltung ausl ten Zur Durchf hrung des Diodentests wie beschrieben verfahren 28 1 Funktionswahlschalter in Stellung Q PHI CAP drehen 2 Ger t auf die Diodentestfunktion durch Dr cken der Taste F2 umschalten In der LCD Anzeige leuchtet das Symbol auf 3 Rote Pr fleitung an den V Q CAP Hz Temp Eingang und schwarze Pr fleitung an den COM Eingang des Ger tes anschlie en 4 Pr fleitungen ber die zu messende Diode anlegen und Messwert in der LCD Anzeige ablesen 5 Pr fleitungen ber den Anschl ssen der Diode vertauschen und Messwert ablesen 6 Wird nach dem ersten Anlegen oder nach dem Vertauschen der Pr fleitun

Download Pdf Manuals

image

Related Search

Related Contents

PDF Manual  Air Navigation Pro 4 MANUAL DE USUARIO  Safety and Instruction Manual for HT05 Ultimate Blade  Manual de usuario  MD Building Products 25714 Installation Guide : Free Download, Borrow, and Streaming : Internet Archive  Zebra A100 User's Manual  USER GUIDE GUIDE DE L`UTILISATEUR  to our FP Panel installation manual - C-Tec    Nielsen Answers v6.1  