1. 6 j COMMAND IPT j COMMAND OPT j COMMAND ANI 0 00 j COMMAND SIG j COMMAND H SYSTEM INFO MODEM MODE RESTORED lt COM w 9800 w 8 w N w 1 w 55 7M Cose T E EE E E E ing 115200 7E1 RTS TX RX CTSDSR DCD RI L Default serial parameters are 9600 8 N 1 SMARTOO Telemetry System 10 2014 All rights Reserved 5 PROGRAMMING AND CONFIGURATION VIA YAT 5 1 Testing Installed Signal Quality Use the Signal Strength tool in YAT to check the received signal strength of the serving cell as well as the neighbouring cells Click on lt Once gt for a quick test or lt Repeat gt to test the antenna at different positions Timing Advance can be selected to determine and display the approximate distance to the serving cell The first bar on the left is the signal strength to the serving cell and should be above 10 green YAT Pro by TruTeq Wireless Pty LTD File Terminal Tools Help Modem Signal Strength Timing Advance Signal Strength 0000 Cell ID cow neo e D se 7 99 99 OS u RTS TX RX CTSDSRDCD RI SMARTOO Telemetry System 11 2014 All rights Reserved 6 SMARTONE ELECTRICAL INTERFACES Serial Port SIM card input 6 1 DC Power Supply The TruCom SmartOne DC input is protected against reverse polarity and over voltage Input Protection 6VDC 15VDC Tranzorb Poly switch Typical connection diagram EE TRu
2. only if not in data call 2 Ifa data call is not terminated for longer than 45 minutes 3 If the modem loses GSM network authentication for longer than 10 minutes If the modem is in a data call when the 24hr reset cycle starts the modem will wait for 10 minutes before resetting The default reset options are 1 Every 24 hours only if not in data call 2 If the modem loses GSM network registration for longer than 10 minutes 1 7 GPRS Manager The SmartOne uses the GPRS bearer to establish a transparent serial link between the IED and the user application GPRS networks have been designed for hand held units to browse the internet with Because of this the network will assume disconnects and re connects from users via their hand held units Installing a modem in a remote and fixed location with no user intervention will require some sort of management of the GPRS link The SmartOne is fitted standard with a GPRS manager This manager ensures that the modem stays ready and connected on the GPRS network Various parameters can be set to ensure connectivity to the meter at any given time The manager includes a periodic ping to a specified server in order to keep the GPRS availability up Command 161 specifies the manager time outs Parameter 1 GPRS re attach interval This parameter specifies the number of minutes to wait before re attaching to the GPRS network Parameter 2 GPRS error re try interval This parameter specifies
3. 2014 All rights Reserved 9 DISCLAIMER TruTeg Wireless does not accept any direct or indirect liability for the use of any TruTeg product The customer takes full responsibility for its use and any liability or damage that may arise from the use of the TruTeq Wireless product NOTE This product is not designed or certified for use as medical equipment or with medical equipment or with medical devices This product is also not designed or certified to be used with any medical services or medical related services 10 GLOSSARY API Application programmers Interface ASN 1 Abstract Syntax Notation One CDR Charge Data Record CSV Comma Separated Values Database DNS Domain Name System FQDN Fully Qualified Domain Name GAIN Gateway Application and Interface Node HTTP Hypertext Transfer Protocol HTTP Secure Interactive Voice Response Input Output Internet Protocol Multimedia Message Service Multimedia Messaging Service Centre Personal Digital Assistant Short Message Service Centre Short Message Peer to Peer Protocol Unstructured Supplementary Services Data WIG Wireless Internet Gateway WAP Wireless Application Protocol WML Wireless Mark up Language WASP Wireless Application Service Provider XML Extensible Markup Language 11 REVISION INFORMATION Date Version Comments S Author Create document Eric Guldemond Eric Guldemond Eric Guldemond Add comment on pulse counters Eric Guldemond Eric Guldemond
4. eee SMARTOO Telemetry System 20 2014 All rights Reserved 12 CONTACTING TRUTEQ WIRELESS Telephone 27 12 6671530 Fax 27 12 6671531 Web www truteq com email information truteg com Snail Mail PO Box 12220 Centurion 0046 SOUTH AFRICA TruTeq Wireless Pty LTD Ameton House 1028 Clifton Avenue Lyttelton Manor Ext 3 Centurion 0157SOUTH AFRICA 13 NOTICES amp TRADEMARKS Copyright Notice Copyright 2013 TruTeq Wireless Pty LTD All rights reserved No part of this document may be reproduced in any form or by any means without prior written authorisation from TruTeq Wireless Pty LTD Trademarks TruTeq Wireless and the TruTeq corporate logo are trademarks of TruTeq Wireless All other trademarks appearing in this guide are the exclusive property of their respective owners General Notice TruTeg Wireless reserves the right to revise this document without obligation to provide notification of such changes TruTeg Wireless provides this documentation without warranty expressed implied statutory or otherwise and specifically disclaims any warranty of merchantability or fitness for a particular purpose TruTeq Wireless may make improvements or changes in the product s and or the program s described in this documentation at any time TruTeq Wireless assumes no responsibility for product reliability and or performance if any party other than TruTeq modifies the device configuration or if the installation is not pe
5. the number of minutes to wait before re attempting to attach to the GPRS network Parameter 3 Connection no data flow time out This parameter specifies the number of minutes to allow no data to flow through an open TCP connection before assuming a ghost connection L Refer to TruTalk commands 150 to 161 for all the various options Combining CSD and GPRS The GPRS manager automatically detach from GPRS network when a CSD call comes in The call is then answered When the CSD session is over then the modem will re attach to the GPRS network SMARTOO Telemetry System 6 2014 All rights Reserved BOTTOM 1 8 SmartOne Labels TRUTEQ The SmartOne is identified by the top and bottom olo TRUTER en labels The Top label indicates the LEDs and IO SMARTONE connections and also the serial number The Smart Wireless Terminal serial number is visible from the top and includes the year of manufacture R F 1 2 1 2 SIM The bottom label on the SmartOne indicates the Input 6 15Vdc 1 3A Input power specification as well as the IMEI be ee APPROVED 2 EVENTS An event is a change in condition and where certain commands then need to be executed 2 1 Digital Input events Separate Command Lists are linked to the events where an input goes high on open or low off closed The delay times also known as the debounce times before the unit registers a change in input state can be configured 2
6. 2 Timer events Separate Command Lists are linked to the events where a timer runs out There are 5 separate timers 2 3 User Variable events Separate Command Lists are linked to the events where a user variable reaches one of its low or high levels There are 5 different user variables each with its own high and low levels SMARTOO Telemetry System 7 2014 All rights Reserved 2 4 Analogue events Separate Command Lists are linked to the events where an analogue value passes a certain level The following diagram explains which command lists are associated with which level Full Scale Set with cmd 52 E High Level Hysteresis SS A Set with cmd 52 Typical Analogue Level Set with cmd 53 Low Level Hysteresis ae A Set with cmd 53 SMARTOO Telemetry System Zero 2014 All rights Reserved High Trip High Recv Low Recv Low Trip Cmd list 54 exec when level goes past this point Cmd list 55 exec when level goes past this point Cmd list 56 exec when level goes past this point Cmd list 57 exec when level goes past this point 3 SMARTONE START UP The SmartOne will print BOOT information on start up This information is printed on the serial port at the last baud rate and framing that the SmartOne was set to with command 257 The SmartOne is ready for operation once the Start up complete sentence is printed One can now enter commands via command mo
7. CALSPECIFICATIONG nea enaknoua EEEE veta 19 8 OTHER SPECIFICATIONS EE 19 8 1 unue m 19 8 2 Manufacturer s Type Number 19 CH ne E EE 20 O e EE 20 11 REVISION INFORMATION 20 12 CONTAC FNG TRUTEO WIRELESO seccnipum nre uroki pidon aE EE S 21 13 NOTCES amp TRADEMARKS ececpaccocesansaesncoznienncesnansnccassaentensaneencanimsandasaeeeeerareeee 21 SMARTOO Telemetry System 2 2014 All rights Reserved 1 INTRODUCTION 1 1 Background The Truteq SmartOne is a versatile industrial RTU Remote Terminal Unit with integral modem for communications to IEDs Intelligent Electronic Devices It can be used in a whole range of applications in the telemetry AMR Automated Meter Reading SCADA security farming home and office automation industries 1 2 SmartOne in Short The SmartOne has the following features e RS232 modem port Activity LEDs External DC input Data logging card Real Time Clock SMARTOO Telemetry System 2014 All rights Reserved 2 Digital Open collector outputs 2 Inputs either Analog or Digital Dual SIM card feature internal Chip SIM optional Easy scripting language to configure the unit ess Termin ai Sman Wie TRUTEg M WTD sy 1 3 System Description The SmartOne is a smart telemetry device but still supports AT commands including the Hayes command set Even though the SmartOne can act like a GSM modem it offers much more in term
8. TEG en eos V TWTD S1 1 0 SMARTONE Smart Wireless Terminal Batt charger SMARTOO Telemetry System 12 2014 All rights Reserved 6 2 Digital Outputs The SmartOne digital outputs are protected open collector format The output can sink 15Vdc 200mA Typical connection diagram ho ale TRUTES e a NE Smart Wireless Terminal SS O ce ce O O Ss T sw pes pes EE E EE peas Batt charger SMARTOO Telemetry System 2014 All rights Reserved 13 6 3 Inputs The SmartOne inputs can be either Digital or Analogue In Digital mode the SmartOne can activate an internal weak pull up to enable the use of a potential free contact as a digital input In Analogue mode that SmartOne can activate an internal voltage divider to enable the measurement of up to 22Vdc monitoring Alternatively the SmartOne can activate an internal shunt load to enable the use of 4 20mA sensors Inout options set via command 31 Voltage Divider option 0 Pull Up option 1 Shunt option 2 SmartOne SmartOne SmartOne External External External Input Input Input L Note See command 33 for Analogue and Digital selection options Note The SmartOne also monitors its own supply voltage see command 180 CR Note The SmartOne also has pulse counters see commands 87 amp 88 Typical connection diagrams Potential free digital Pull up option enabled tes V TWTD S1 1 0 SMARTONE S
9. art SO RJ12 DB25 A1700 for Elster meters O RJ12 6 iit Zeg Female bh SMARTONE A1700 4V0 RX O n T TX 5 oc LO RTS I N Q CTS O GND ee To use the above configuration then CTS needs to be enabled by setting 259 1 0 6 4 3 RJ12 serial cable pin out Part SO RJ12 RJ12 ZMD for Landis amp Gyr meters Add tag to indicate Modem side SMARTONE ZMD 4V0 1 RX O 2 x TX I 3 3 CN T ms B 2 CTS O 5 GND 6 E To use the above configuration then flow control needs to be disabled by setting 259 0 0 SMARTOO Telemetry System 17 2014 All rights Reserved 6 4 4 RJ12 serial cable pin out Part SO RJ12 RJ12 A1140 for Elster A1140 meters E RJ12 6 Add tag to indicate Modem side SMARTONE A1140 4V0 n RX O 2 a TX l 3 E T prs B CTS O 5 GND 6 To use the above configuration then flow control needs to be disabled by setting 259 0 0 SMARTOO Telemetry System 18 2014 All rights Reserved 7 ELECTRICAL SPECIFICATIONS Power supply Input Input Protection Low voltage DC 6VDC 15VDC Tranzorb Poly switch Antenna Connector SMA 8 OTHER SPECIFICATIONS 8 1 Physical Weight Casing material ABS plastic Temperature rating 10 C to 60 C Humidity Up to 90 RH non condensing 8 2 Manufacturer s Type Number The type number for the SmartOne is V TWTD S1 1 0 SMARTOO Telemetry System 19
10. de AT TT or use it as a standard modem YAT Pro by TruTeg Wireless Pty LTD File Terminal Tools Help ee 3 Ww ake ec Shortcuts Clear Echo OFF Log OFF Hex OFF TCPOFF Print Firmware Terminal i X FLASH MAMAGER l d Verifying FLASH DK Starting application Modern Configuration Welcome to TruTeq dxzxz MAESTRO III j VERSIUN v3 55 sERIAL T TOOS D Starting RTC done Time 16 18 23 Date 09 11 10 Local framing 8 N l1 Starting Logging Card NOT found TruT alk Configuring GaN please wait j Configuring GSM completed E Now running user specific init Command AT CBST 0 0 1 gt OF YAT Scripte Command AT CICH 0 gt OK Command AT C5N5 4 gt OK Command AT30 1 gt OK i Command AT CUSD 1 gt DE it Command ATsDO gt OF Communications Command ATs gt K Processor Configuring GPRS please wait j Configuring GPRS completed j Connecting GPRS done IB address 10 123 0 11 j GPRS SERVER MO LISTENING Start up complete Strength Manager lied im COM w 9600 selje el et el in nes 7 200000 we RTS TX RX CTSDSRDCD RI SMARTOO Telemetry System 9 2014 All rights Reserved 4 COMMAND MODE By default the SmartOne serial port acts as a standard modem However this serial port is also used to enter commands and to configure the SmartOne The AT command AT TT is used to enter the standard Trut
11. e TRUTEQ WIRELESS pm erp PRODUCT DOCUMENTATION USER MANUAL M g ae NU D e WW WW e e d OE E Y ema E A S gt iy Um E E Telecommunications Products SMARTOO Telemetry System 1 2014 All rights Reserved TABLE OF CONTENTS TABLE OF GONE ee 2 TWO DIIGO P E E E E E E 3 I Ere gl el De oe R 3 1 2 SmartOne in Ghort ccc eecccsececeeeeceeeeeeeeeseeeeeeeeteaeeteeeeeaeeteeetsneetsneetsneeeas 3 1 3 System ege degt geed deed de dd 4 TADIR US e e 4 EE EA RE 5 4 6 The Ultimate in Stability Comm Biel 6 We E VO MAMA EE 6 18 SOUS Eege 7 32 11 7 Za MIBIenidineiE i a cT TT TT 7 2 2 imer events 7 2 3 User Variable events 7 24 Ahalogue OVO erre EEE A P PPan ob Oo E 8 3 OMARTONE START UP a 9 Lee unpausblze 10 Al i a lee COMMANA E 10 5 PROGRAMMING AND CONFIGURATION VIA AT 11 5 1 Testing Installed Signal Quality 22 00 2000 eeee00 RE 11 6 SMARTONE ELECTRICAL INTERFACES een een nn 12 6 1 DG POWef SUD e E 12 5070 Bo EI Uie UP 13 eee eee er E et er ee ec eet 14 SE too ale OOM OPP oque ierat ten idea educa 16 6 4 1 PC serial cable pin out Part SO RJ12 DB9 PC 16 6 4 2 DB25 serial cable pin out Partt SO RJ12 DB25 A1700 for Elster meters 17 6 4 3 RJ12 serial cable pin out Part SO RJ12 RJ12 ZMD for Landis amp Gyr meters 17 6 4 4 RJ12 serial cable pin out Part SO RJ12 RJ12 A1140 for Elster A1140 meters 18 ELEC TRI
12. eg Text mode command prompt The command mode will time out after a default 30 seconds or can be quitted by typing lt ctrl z gt this will return the SmartOne into normal modem mode A simplified command mode is also available for use with serial applications by entering AT RT Raw Text In this mode there will be no echoing or prompts to simplify the serial encapsulation in a typical application 4 1 Entering Commands Commands can be entered once the SmartOne is in command mode YAT Pro by TruTeq Wireless Pty LTD File Terminal Tools Help Tools l HETEREN Shortcuts Clear Echo OFF LogOFF Hex OFF TCPOFF Print Firmware X FLASH MANAGER 1 0d Verifying FLASH OK Starting application Welcome to TruTeq 4X2X2 MAESTRO III j VERSION V3 55 j SERIAL TSTO006000 j Starting RTC done j Time 16 24 42 Date 09 11 10 Local framing 8 N 1 j Starting Logging Card NOT found j Configuring GSM please wait j Configuring GSM completed j Now running user specific init j Command AT CBST 0 0 1 gt OK Command AT CICB 0 gt OK Command AT C5N5 4 gt OK j Command AT50 1 gt OK j Command AT CUSD 1 gt OK Command AT amp DO gt OK Command ATsW gt OK j Configuring GPRS please wait j Configuring GPRS completed j Connecting GPR5 done j IP address 10 123 0 11 j GPRS SE Rita teaming Son up complete pats tt j SYSTEM INFO COMMAND MODE j COMMAND
13. mart Wireless Terminal Tr gt CE CB cB CH CH Ss Ee Eden AEAEE Potential free door switch ACin 12V 10VA PSU SMARTOO Telemetry System 14 2014 All rights Reserved Analogue Voltage Voltage Divider option enabled DS TO SMARTONE Smart Wireless Terminal K m S CH CH CH CH CH SS T Solar Panel EU SES EEE E Analogue Current Shunt option enabled V TWTD S1 1 0 o SMARTONE Smart Wireless Terminal ZA EAT R m I l3I215I2 2 wire temperature sensor 4 20mA current sink SMARTOO Telemetry System 15 2014 All rights Reserved 6 4 RS232 Data port The RS232 port is the SmartOne primary data port It is an RJ12 6 socket with the following pin out Pin number Description Direction 1 4V Out 2 RX data Out 3 TX data In 4 Flow control In 5 Flow control Out 6 GND L Note The flow in and out functions can be defined as RTS CTS DCD DTR RI or none for more information see command 259 6 4 1 PC serial cable pin out Part SO RJ12 DB9 PC nz C SMARTONE 4V0 RX O TX I RJ12 RTS I CTS O GND To use the above configuration then RTS and CTS needs to be enabled by setting 259 1 1 SMARTOO Telemetry System 2014 All rights Reserved 4 x DB9 Female PC DB9 Female 16 6 4 2 DB25 serial cable pin out P
14. nd Digital Outputs SMARTOO Telemetry System 4 2014 All rights Reserved 1 5 Status LEDs Two LEDs indicate a whole list of statuses to the field installer Heartbeat LED Power ores ni Flash This LED will always flash in some state also indicating the p unit being on and operational 50 on 50 off slow flash No Network found Short Blip Logged on to GSM network GSM Network state Double Short Blip Logged on to GPRS network Short flash Logged on to GSM network low signal Double Short flash Logged on to GPRS network low signal Information LED 50 on 50 off flash SMS activity On flashing off Modem transmits data Data Carrier Detect On with off Blips Busy in data call or GPRS session SMARTOO Telemetry System 5 2014 All rights Reserved 1 The Ultimate in Stability Comm Alive Telemetry users know that their devices are often in remote or inaccessible areas The last thing they can afford is to have to continuously visit a number of sites to reset these devices There are four major causes of failures in GSM based telemetry 1 Lock ups between modem and GSM network 2 Not terminated data calls 3 Loss of network authentication 4 Unknown network or modem status By using proven and patented technology the SmartOne is kept as stable as possible Depending on the customer s preferences on order the modem will reset under any of the following conditions 1 Every 24 hours
15. rformed in accordance with this manual SMARTOO Telemetry System 21 2014 All rights Reserved
16. s of communications inputs and event based programming The SmartOne is a type class B GPRS multi slot class 10 device It is intended for use on the 900MHz extended and 1800MHz GSM frequency bands By using simple commands the SmartOne can switch between using CSD circuit switched data calls or GPRS to communicate with a device on the serial port Two fully programmable inputs timers counters variables and other events provide a very powerful and future proof solution for industrial communications The SmartOne executes the scripted Commands that are linked to all the triggered events as well as scripted Commands received via SMS CSD call or GPRS connection A triggered event can be for instance an input going from high to low or the timer that runs out Commands can for instance send SMS report status to a server toggle an output or clear a timer Events Command Lists Event A Command Command Command Script linked to event A Event B Command Command Command Script linked to event B Event C Command Script linked to event C Script contained in SMS lt Command gt lt Command gt SMS messages sent to the SmartOne are executed as a script 1 4 Digital vs Analogue Unless specified otherwise all inputs and outputs referred to in this manual are Digital inputs a