Home

Guide to lodging EPCs with JPA Designer

image

Contents

1. EPC Request Management dialogue opens 2 Select the lodgement by clicking on the row in the EPC Submissions table This makes the first row of buttons active 3 Click the Get RRN button Figure 3 3 JPA Designer copies the RRN to the Windows clipboard 4 Open your web browser and go to the Landmark web site 5 For England and Wales https www epcregister come 6 For Northern Ireland https www epbniregister come 7 On the home page click the link below Retrieve an Energy Performance Certificate The link is labelled Click here This is a change from the previous arrangement and has been introduced following instructions from BRE that assessors are no longer allowed to obtain the final EPC from SAP software but must download it from Landmark https www epcregister com https www epbniregister com CHAPTER 3 LODGING AN EPC 8 8 10 11 12 13 14 On the Retrieve an Energy Performance Certificate page click in the RRN box and paste the RRN from the Windows clipboard You can do this by right clicking the mouse and selecting Paste from the pop up menu or you can press lt Ctrl P gt Now type the distorted numbers in the image into the box immediately below This is a security check to prevent computer programs logging into the system Click Retrieve report The site now displays a page setting out the conditions for retrieving the EPC Near the bottom of the page click Accept
2. Medium Total heat cap Figure 4 1 Setting the thermal bridging and thermal mass There have been other changes in the EPC lodgement data set which affect mid floor and top floor flats but not ground floor flats you must now indicate if a flat has another occupancy beneath it and the floor is therefore a party floor As this was not a requirement under SAP 2006 you must add a party floor element to the SAP 2009 calculation 1 In the Dimensions tab tick the party box next to the storey which has the area assigned e g first floor CHAPTER 4 EPCS FOR DWELLINGS ASSESSED WITH SAP 9 81 11 2 In the Walls roofs amp floors tab create a new element e Set the Element type to Party floor e Pick a construction to set a heat capacity e Set the Storey to the appropriate number e Assign a U value of zero e Set the Area to the same size as the storey area in the Dimensions tab e Click OK Note that this makes it important to enter the floor area of the flat against the correct row in the Dimensions tab 5 Lodgement problems This section describes how to identify and resolve data problems which result in EPC lodgements failing It also describes how to get help for those problems and how to request a UPRN for a dwelling which does not appear on the Landmark database 5 1 Identifying the cause of a failed lodgement Sometimes an EPC submission is unsuccessful and the EPC fails to lodge with Land mark This usuall
3. from a SAP 9 90 calculation for the dwelling The simplest way of producing a SAP 9 90 calculation for the dwelling in JPA Designer is to use the Copy SAP 2005 9 8x dwelling to SAP 2009 dwelling option on the Edit menu in the Project Manager window Of course the SAP 9 90 TER and DER figures will show considerably worse performance than the comparable SAP 9 8x figures and may even show a fail However the SAP 9 90 TER DER are not used for compliance the SAP 9 90 calculation is used only for producing the EPC 4 1 Converting SAP 9 81 to SAP 9 90 To convert a SAP 9 81 calculation to SAP 9 90 in order to lodge an EPC 1 Select the SAP 9 81 calculation in the Project Manager window by clicking on it once 2 From the Edit menu select Copy SAP 9 8x SAP 2005 dwelling to SAP 9 90 SAP 2009 dwelling This creates a SAP 9 90 version of the dwelling but leaves the original calculation intact 3 Open the new SAP 2009 calculation and check the data items listed in kection 4 2 4 Return to Project Manager and save the project You can now obtain the UPRN for the dwelling section 3 2 and then lodge the EPC section 3 3 The change over dates were 17 April 2011 for England and Wales and 31 October 2012 for Northern Ireland CHAPTER 4 EPCS FOR DWELLINGS ASSESSED WITH SAP 9 81 10 4 2 Data to check You must check the following items for all converted calculations Thermal bridging if the thermal bridging in the SAP 2005 calc
4. gt 1010 lt ERR ErrorCode gt lt ERR ErrorMessage gt ClientXmllsInvalidException The XML submitted is invalid cvc type 3 1 3 The value 1 of ele lt JERR Exception gt bs ii gt Copy to clipboard Figure 5 2 Viewing the exception list for a failed lodgement CHAPTER 5 LODGEMENT PROBLEMS 14 e inthe future e more than two years in the past this is more likely to be an issue with calculations converted from SAP 2005 to SAP 2009 than with calculations starting in SAP 2009 e earlier than the date on which you were registered as an assessor e Dwelling type and dwelling dimensions if the dwelling type has been set as a mid floor or top floor flat or maisonette the dwelling floor area in the Dimensions tab must be set to an appropriate story Setting a mid floor flat but entering the floor area against Ground floor will result in a failure e Dwelling type and elements a house must have a ground floor element in the Walls roofs amp floors tab Defining that floor element as a floor rather than ground floor will result in a failure e Flats and party floors Mid floor and top floor flats must now be marked as party floors in the Dimensions tab They must then have a party floor element defined in the Walls roofs amp floors tab for instructions see Sew 5 3 Getting help If you are unable to identify the cause of a failed lodgement you can ask the advice of your accreditation scheme or contact us at J
5. terms At the next page leave Retrieve the latest report at Yes and the Report retrieval format as PDF Then click Retrieve report The next page shows the summary data for the EPC lodgement Click Click here to view report PDF The EPC will then be downloaded to your PC as PDF which you can then issue to your client Database location C Program Files JPATL JPA Designer 981 JPA_EPCS mdb JDP File psf Home Documents Writelines JPA Software SAP queries SAP queries 2011 79 lindfield JDP Dwelling 79 High St Lindfield SAP 2009 Version 990 en Refresh EPC list View returned value Get RRN amp Open draft EPC E Extract source JDP fle Make XML it Delete one record Compact database Close Figure 3 3 The Get RRN button at the bottom of the EPC Request Management dialogue 4 EPCs for dwellings assessed with SAP 9 81 EPCs for all new dwellings have to be lodged using SAP 2009 SAP 9 90 even if the original design stage compliance calculations were carried out using SAP 2005 either SAP 9 80 or 9 81 This means that the final submission for building regulations compliance and the EPC have to be produced separately e The TER DER outputs and the Regulations checklist must be produced from the SAP 9 80 9 81 calculation revised if necessary to take account of any changes since the design stage Regulations compliance will be based on these results e The EPC must be lodged
6. From the Project Manager menu bar select EPC gt Request V15 EPC for this dwelling CHAPTER 3 LODGING AN EPC 7 3 The software displays an information dialogue Submitting a request for an EPC will cause your account to be charged Are you sure you want to continue To continue in order to issue an EPC click Yes 4 JPA Designer now collates the data and generates a draft EPC which is displayed for approval in the EPC Preview dialogue If you are happy with the EPC click I approve this EPC proceed with submission 5 JPA Designer prepares the final EPC and accompanying submission data then tells you how much data will be uploaded Click OK to start the upload 6 JPA Designer notifies you when the submission is complete and whether or not it has been successful If the lodgement was successful you can now obtain the final EPC for distribution tion 3 4 If it failed you need to identify the problem in order to attempt the lodgement again chapter 5 3 4 Issuing EPCs Once the EPC has been lodged successfully you have to go to the Landmark web site to download a PDF of the EPC which you can then issue to your client In order to download the EPC you will need to have the RRN which is the unique reference number for the lodgement You can get the RRN for the lodgement using the EPC Request Management dialogue 1 Once the EPC has been successfully lodged select EPC gt EPC Request Manage ment from the Project Manager menu bar The
7. Issuing EPCs with JPA Designer 5 04 JPA TL Ltd October 26 2012 Contents 1 Introduction Setting up JPA Designe 1 Initial requirements 2 2 Entering your accreditation detail 3 Entering your accreditation details for BR 4 EPCs for dwellings assessed with SAP 9 81 4 1 Converting SAP 9 81 to SAP 9 90 5 4 Dwellings without a UPRN E NOUV U UU NNN _ N 12 12 12 14 15 1 Introduction This manual explains how to prepare and lodge on construction Energy Performance Certificates EPCs for new dwellings using JPA Designer It covers England and Wales and Northern Ireland it does not address issuing EPCs in Scotland where there is no requirement for electronic lodgement The manual describes how to e prepare JPA Designer for lodging EPCs e lodge EPCs for dwellings using SAP 2009 SAP 9 90 e lodge EPCs for dwellings where the original SAP calculation was carried out using SAP 2005 SAP 9 81 e identify and resolve common causes of lodgement failure This manual is not a guide to carrying out SAP calculations using JPA Designer for that ou Sicona ke etre manuel Ne 00 oc ene anc the Conventions document Lodging EPCs is by and large a straightforward process however setting up the software for the first time and making your first lodgement can take some time We therefore recommend that you familiarise yourself with the process in good t
8. PA TL email enquiries only to sup port techlit co uk When you are making an enquiry please ensure 1 You are using the latest version of the program You can get your version number by going to About on the Help menu and can then compare that with the version number shown on the home page of our web siteZ You can find more information on this in section 2 5 of the JPA Designer User Manual 2 You have followed the recommendations for resolving problems in this manual and have reviewed the common causes of failure Section 5 2 3 In your email 4 tell us which accreditation scheme you are with 5 paste the Lodgement Return Values into the body of the email there is no need to put it in a separate document 6 attach the JPA Designer project file for the calculation That will have the extension JDP There was at one stage an issue with the application date being set to the date of the lodgement if the lodgement was made before noon That does not seem to have been an issue recently http Avww techlit co uk http Avww techlit co uk downloads manual501 pdf CHAPTER 5 LODGEMENT PROBLEMS 15 5 4 Dwellings without a UPRN There may be occasions when you cannot obtain a UPRN for a dwelling because it has not been added to the Landmark database If that happens you can request the property be added using the Landmark web site Before you go to the web site you will need to install the digital security certific
9. PZ 35 08 06 2011 15 16 27 E 1 Chelsea Street 574 105 34 08 06 2011 15 08 51 E 1 chelsea Street 574 105 33 08 06 2011 15 06 57 EE 1 Chelsea Street 574 105 32 18 05 2011 09 52 53 E 45 Caesar Avenue TN23 3 Z 31 18 05 201109 49 53 IE 45 Caesar Avenue TN23 3 Z 30 17 05 2011 11 24 46 J 45 Caesar Avenue TN23 3 Z 29 17 05 2011 11 23 48 E 45 Caesar Avenue TN23 3 Z 28 17 05 2011 11 22 14 I 45 Caesar Avenue TN23 3PZ 27 17 05 2011 11 21 07 J 45 Caesar Avenue TN23 3 Z 26 17 05 2011 11 17 58 I 45 Caesar Avenue TN23 3 Z 25 17 05 2011 11 14 47 J 45 Caesar Avenue TN23 3PZ 24 17 05 2011 11 11 10 J 45 Caesar Avenue TN23 3 Z 23 17 05 2011 11 09 31 J 45 Caesar Avenue TN23 3 Z Database location C Program Files JPATL JPA Designer 981 JPA_EPCS mdb JDP File psf Home Documents Writelines JPA Software SAP queries SAP queries 2011 Merlin Cresent Block 1 Flat 1 JDP Dwelling Merlin Crescent Block 1 Flat 1 SAP 2009 Version 990 E Refresh EPC list View returned value Get RRN Open draft EPC Figure 5 1 The EPC Request Management dialogue Lodgement Return Values Return value 0 Return XML lt ExceptionList gt lt ERR Exception gt lt ERR ErrorCode gt 1010 lt ERR ErrorCode gt lt ERR ErrorMessage gt ClientXmllsInvalidException The XML submitted is invalid cvc enumeration valid Yalue 1 is r lt JERR Exception gt lt ERR Exception gt lt ERR ErrorCode
10. RE e Default related party disclosure The regulations regarding EPCs require an asses sor to declare any financial or family relationship with the party who is building or selling the dwelling You would have to make a disclosure if for example you are issuing EPCs for houses built and sold by your employer or for a house built by a member of your immediate family You can change the default related party disclosure for individual calculations using the Project Information dialogue within the SAP calculation e Insurance details The details of your public indemnity insurance policy To update your accreditation details 1 On the EPC menu select Energy Assessor accreditation details The Energy Assessor Accreditation Details dialogue opens 2 From the Scheme name list select BRE 3 Enter the Accreditation number supplied by BRE 4 Leave the username and password fields blank 5 Enter the contact details Company down to web address These details must match those held by BRE 6 Select a related party disclosure from the Default related party disclosure drop down 7 Enter the Insurance details Insurance company name policy number effective and expiry dates and PI limit 8 Click OK to close the dialogue and save the data 3 Lodging an EPC 3 1 An overview of the lodgement process The main steps for lodging an EPC are 1 Revise the as designed SAP calculation to take account of any changes made during constru
11. ate pro vided by your accreditation scheme To request a property be added to the database In your web browser go to the Landmark web site England and Wales https www epcregister com Northern Ireland https www epbniregister com On the welcome page click Authorised users The site displays a Client Authentication dialogue Select the digital certificate from your accreditation body and click OK The site shows a terms and conditions page Click Accept terms On the Address Services page scroll down to Request Property Address Addition and follow the link to add an address labelled click here On the Request Property Address Addition page enter the details of the property and your accreditation number then click Request Address Addition Landmark should process the request within 24 hours and should notify you by email once the URPN has been assigned You can then try to get the UPRN in JPA Designer again 4 5 ttps www epcregister com ttps www epbniregister com
12. ction and to include the assessed air permeability 2 Obtain the UPRN Unique Property Reference Number for the dwelling 3 Upload the EPC data to Landmark 4 Retrieve the lodged EPC from Landmark and issue it to your client 3 2 Obtaining the UPRN for the dwelling Before you can issue an EPC for a dwelling you must obtain its Unique Property Reference Number UPRN which identifies it on the Landmark database JPA Designer uses the SAP module s Project Information dialogue to look up and store the UPRN for each property Figure 3 1 Project Information amp Options pee Client name amp address Project address Mr A T Builder X Mr A T Builder The Old Yard Tawnyyville Suedeshire Post Code get UPRN PostCode BN123DR UPRN clear UPRN Figure 3 1 Project address To look up a dwelling s UPRN CHAPTER 3 LODGING AN EPC 6 1 Open the SAP calculation for the dwelling 2 Open the Project Information dialogue from the menu bar or tool bar 3 Enter the post code for the dwelling in the Post Code box of the Project address section 4 Click the get UPRN button The UPRN Address dialogue opens with the post code from the Project Information dialogue in the Postcode box Figure 3 2 5 Click the Look up button The software displays the addresses which match that post code 6 Click on the address of the dwelling for which you intend to produce an EPC then click the Look up UPRN button The software requests t
13. he UPRN from the server and displays it If there is no matching address it may well be that the dwelling does not yet have a UPRN In that case you should contact Landmark and request a UPRN for the Facing seeker 7 If the address is correct click Use this UPRN amp address The UPRN Address dia logue closes leaving the Project Information dialogue with the address and UPRN Once you have selected the UPRN the address details will be greyed out and you will not be able to edit them If you need to change the address you must first click Clear UPRN UPRN Address x Enter a Postcode and press Look up button then select the address from the list and press Look up UPRN button Postcode INEZ 1QQ Look up Matching addresses ugano 9 Portland Terrace NEWCASTLE UPON TYNE NE2 1QQ etro Industrial Holdings 9 Portland Terrace NEWCASTLE UPON TYNE NE2 100 John Potter Architect 10 Portland Terrace NEWCASTLE UPON TYNE NEZ 100 Browne Smith Baker Llo 11 12 Portland Terrace NEWCASTLE UPON TYNE NE2 100 Figure 3 2 Looking up the UPRN 3 3 The lodgement process An EPC for a dwelling must be lodged to Landmark s national database You should only lodge an EPC once the final as built SAP calculation has been carried out The following instructions presume you have finalised the calculation and have obtained the UPRN for the dwelling To lodge an EPC with Landmark 1 Save the project file 2
14. ime and don t set out to lodge your first EPC at 4 00 pm on a Friday afternoon 2 Setting up JPA Designer 2 1 Initial requirements Before you can issue an EPC for a dwelling you must e have installed JPA Designer 5 04a1 or later and have a valid licence for the software e make sure your computer has an active internet connection so it can upload the EPC submission to Landmark e be registered with an On construction EPC accreditation scheme and enter your accreditation details into JPA Designer Section 2 2 e make sure JPA Designer is configured to use version 15 of the lodgement format the program is configured to use this version known as XML v15 you can check this on the Other tab of the Options dialogue Select Options from the Project Manager window to open the dialogue 2 2 Entering your accreditation details Before you can issue an EPC you must enter your accreditation scheme details into JPA Designer using the Energy Assessor Accreditation Details dialogue Figure 2 1 For the BRE scheme follow the instructions in the next section The Energy Assessor Accreditation Details dialogue holds the following information e Scheme name the name of the On Construction EPC accreditation scheme of which you are a member e Accreditation number Your unique accreditation number within the scheme e Username and Password used to log on to the accreditation scheme s servers e Contact details Your contact detail
15. ng data from the accreditation scheme s systems If you find there is a mistake in the details you should contact your accreditation scheme to have it corrected it is not possible to correct the information in JPA Designer 2 3 Entering your accreditation details for BRE Before you can issue an EPC you must enter your accreditation scheme details into JPA Designer using the Energy Assessor Accreditation Details dialogue Figure 2 2 The Energy Assessor Accreditation Details dialogue holds the following details e Scheme name The name of the On Construction EPC accreditation scheme of which you are a member in this case select BRE from the dropdown e Accreditation number Your unique accreditation number within the scheme The BRE accreditation scheme does not use the username and password fields CHAPTER 2 SETTING UP JPA DESIGNER 4 Energy Assessor Accreditation Details x SRE HHneee eee e eee EEE EEE EEE EEE EEEEEEEEEEEEEEEEEEEEEEEEEEEESEEEEEEEEEEEEEEEEEEEEEEEEEEEESEEEEEESEEEESSEEEESSEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE ESSE ESSE EE ESOS mr NeeeeeeeeeeneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeSeeEESEEeSESEEEEEESEEEEEEERESEESSEESESEDESEESESEESSEOEEESSSESESESEEEEESEEEEEESEEEEESDEEES ESS Accreditation number QUAT999999 Username case sensative Password case sensative Figure 2 2 Energy Assessor Accreditation Details BRE scheme e Contact details Your contact details which must match those held by B
16. s which are held by the accreditation scheme Landmark is the company the Government has chosen to maintain the central electronic register of EPCs for England and Wales and Northern Ireland CHAPTER 2 SETTING UP JPA DESIGNER 3 Energy Assessor Accreditation Details x Scheme name StomaAcceditation Accreditation number Username case sensative Myname Password case sensative Mypassword Look me up Figure 2 1 Setting the Energy Assessor Accreditation Details e Default related party disclosure The regulations regarding EPCs require an asses sor to declare any financial or family relationship with the party who is building or selling the dwelling You would have to make a disclosure if for example you are issuing EPCs for houses built and sold by your employer or for a house built by a member of your immediate family You can change the default related party disclosure for individual calculations using the Project Information dialogue within the SAP calculation e Insurance details The details of your public indemnity insurance policy To set your accreditation details 1 On the EPC menu bar select Energy Assessor accreditation details The Energy Assessor Accreditation Details dialogue opens 2 From the Scheme name list select the scheme of which you are a member 3 Enter the Username and Password supplied by the scheme and click Look me up JPA Designer will complete the boxes usi
17. ulation is set to accredited construction details it should become a user defined y value of 0 08 with the calculation reference ACD 2006 regulations Figure 4 1 There is no need to change settings if thermal bridging is set to Not accredited construction details or a manually calculated Htb value Thermal mass where thermal mass was not defined in the SAP calculation it should be set to 250 kJ m K medium To do that in JPA Designer 1 In the Walls roofs amp floors tab tick User defined Thermal Mass Parameter Figure 4 1 2 Set the Thermal mass drop down to 250 Air pressure test a design value for a SAP 2005 dwelling which is not pressure tested should remain a design value for SAP 2009 even though this is not a standard condition Appendix Q any new technologies entered using the Appendix Q procedure should be left as they are Community heating where there are two boilers feeding one community heating scheme or a boiler and a CHP unit the systems must be re entered as two heat sources with the relevant characteristics see section 22 3 6 of the JPA Designer manual Other items other items of data which are not set in the SAP 2005 calculation can be ignored in the SAP 2009 calculation Thermal Bridging Enter Htb value manually Hib 0 0000 Calculate it Enter y value manually y 0 0300 Calc Ref ACD 2006 regulations Not accredited construction details TMP Thermal mass d User defined Thermal Mass Parameter 250
18. y happens because of inconsistencies in the data which are caught by Landmark s checking systems If a lodgement fails you can view the failure report from Landmark in JPA Designer and correct the problem before trying the lodgement again To view the report from a failed lodgement 1 2 Open the EPC Request Management dialogue Figure 5 1 Click once on the failed lodgement so it is highlighted Click View returned value The Lodgement Return Values dialogue opens ure 5 2 Scroll down the Return XML area to the Exception List section The cause of the failure will be given here If the cause of failure is not clear and the codes are not always helpful use the Copy to clipboard button to copy the report You can then paste it directly into an email and send it to your accreditation scheme or JPA TL for advice 5 2 Common causes of failure Lodgements generally fail because of mismatches between different items of data The commonest ones are e Dates the application date is found at the bottom of the Dimensions tab This must not be CHAPTER 5 LODGEMENT PROBLEMS 13 EPC Request Management x EPC Submissions Successfully lodged or lodgement failed id Date Submitted Status Property address 39 14 06 2011 14 34 08 45 Caesar Avenue TN23 3PZ E 38 14 06 2011 14 32 40 IE 1 Knights Place Ex4 9AL 37 13 06 2011 16 07 49 I 45 Caesar Avenue TN23 3 Z 36 13 06 2011 12 31 20 J 45 Caesar Avenue TN23 3

Download Pdf Manuals

image

Related Search

Related Contents

Visualizza - Service, Support    PDF- FQ2  T804 DIGITAL VIDEO RECORDER – OPERATING INSTRUCTIONS    Proposta de DIRECTIVA DO PARLAMENTO  Seagate Desktop ATA Hard Drives Ultra 160GB Hard Drive Kit  Equerre d`Argent » 2010 - Médiathèque Intercommunale du Piémont  

Copyright © All rights reserved.
Failed to retrieve file