Home

Quick Draw Electronics Competition Controller User Manual Model

image

Contents

1. 3 Quick Draw Electronics Competition Controller User Manual Model CC100 Silent Line Out Volume Power Slave Start Voice Practice Competition Controller _ ee Rev C July 2011 WELCOME TO THE QUICKDRAW ELECTRONICS COMPETITION CONTROLLER THE BASIC SYSTEM CC100 CONSISTS OF 1 CONTROLLER BOX 1 CONTROLLER TO TIMER CABLE 1 POWER SUPPLY SETUP SET UP IS QUICK AND EASY START BY PLUGGING IN A PUSHBUTTON FROM ONE OF YOUR TIMERS TO THE JACK LABELED START ON THE BACK OF THE COMPETITION CONTROLLER BOX 2 PLUG IN THE CONTROLLER TO TIMER CABLE TO THE JACK LABELED SLAVE 3 CONNECT ALL OF THE TIMERS TOGETHER IN A DAISEY CHAIN AS SHOWN IN THE DIAGRAM BELOW IF A PUBLIC ADDRESS SYSTEM IS AVAILABLE CONNECT A CABLE FROM THE LINE OUT OF THE CONTROLLER TO THE LINE IN OF THE PA SYSTEM THE CONTROLLER ACCEPTS A 1 8 INCH MONO PLUG 4 PLUG IN THE POWER CORD OF THE AC DC CONVERTER TO THE POWER JACK ON THE BACK OF THE COMPETITION CONTROLLER BOX PLUG THE AC DC CONVERTER INTO POWER SOURCE PLUG THE AC DC CONVERTERS FOR ALL TIMERS AND THE CONTROLLER INTO THE SAME PLUGSTRIP SO THAT THE POWER FOR ALL OF THE COMPONENTS CAN BE SWITCHED ON AT THE SAME TIME NOTE IF THE POWER FOR ALL TIMERS AND CONTROLLERS ARE NOT SWITCHED ON AT THE SAME TIME THE UNITS CAN GET OUT OF STEP WITH EACH OTHER AND CAUSE A MALFUNCTION 5 YOU ARE READY TO START NOTE THE JACK ON THE FAR RIGHT IS FOR FACTORY USE AND FUTURE EXPANSION IT IS NOT NEEDED IN NO
2. 0 SECONDS AND WHEN IT IS UP THE DELAY TIME IS 3 5 SECONDS THE TIP OF A PENCIL OR A SMALL SCREWDRIVER IS BEST USED TO MANIPULATE THIS SWITCH OPTIONAL EQUIPMENT THE OPTIONAL DC POWER CABLE MAY BE USED WITH AN AUXILLARY POWER UNIT OR BATTERY THE COMPETITION CONTROLLER WILL CONTROL AN UNLIMITED NUMBER OF TIMERS TO ADD TIMERS A SLAVE CABLE IS NEEDED FOR LARGE EVENTS A PUBLIC ADDRESS SYSTEM IS RECOMMENDED WARRANTY THE CONTROLLER IS WARRENTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP TO THE ORIGINAL PURCHASER FOR ONE YEAR FROM DATE OF PURCHASE THE PURCHASE IS AUTOMATICALLY REGISTERED WITH QUICK DRAW ELECTRONICS UPON PURCHASE NO ADDITIONAL WARRANTY REGISTRATION IS REQUIRED
3. E MIDDLE POSITION WHEN IN THIS MODE THE CONTROLLER WILL SPEAK A SHOOTER ON THE LINE SHOOTER SET COMMAND WHEN THE PUSHBUTTON IS RELEASED THE VOLUME OF THE VOICE ANNOUNCEMENT IS CONTROLLED BY THE VOLUME CONTROL ON THE TOP OF THE CONTROLLER BOX CLOCKWISE INCREASES THE VOLUME AND COUNTER CLOCKWISE DECREASES THE VOLUME THE FULL COUNTER CLOCKWISE POSITION TURNS THE SPEAKER OFF AFTER THE SHOOTER SET ANNOUNCEMENT IS COMPLETE THE CONTROLLER STARTS A RANDOM TIMER JUST LIKE IN THE SILENT MODE THE DELAY TIME IS 0 TO 3 SECONDS THE END OF THE DELAY TIME THE TIMER IS COMMANDED TO START A 2 SECOND DELAY BEFORE IT STARTS THE TIME MEASUREMENT THE OPERATOR HAS THE OPTION OF STOPING THE ANNOUNCE SEQUENCE AND SUBSEQUENT STARTING OF THE TIMER IN AN EMERGENCY TO ACCOMPLISH THIS PRESS AND RELEASE THE PUSHBUTTON QUICKLY DURING THE VOICE ANNOUNCE THE ANNOUNCEMENT WILL STOP AND THE CONTROLLER WILL GO BACK TO THE READY STATE PRACTICE MODE THE PRACTICE MODE IS SELECTED BY PUTTING THE TOGGLE SWITCH INTO THE FULL UP POSITION WHEN IN THIS MODE THE CONTROLLER GOES THRU THE SEQUENCE OF STEPS AS IN THE VOICE MODE IT SPEAKS AND THEN AFTER A RANDOM DELAY STARTS THE TIMERS IN ADDITION IT STARTS A TIMER TO WAIT EITHER 3 5 SECONDS OR 10 SECONDS BEFORE AUTOMATICALLY PRESSING THE START PUSHBUTTON FOR YOU THE SELECTION OF THE 3 5 SECONDS OR 10 SECONDS IS DONE BY THE POSITION OF THE OPTION SWITCH 4 WHEN THE SWITCH IS DOWN THE DELAY TIME IS 1
4. RMAL USE THE NEXT STEP IS TO PUT THE TIMERS IN THE SLAVE MODE THIS IS DONE BY PUTTING THE CONTROLLER INTO THE SILENT MODE SEE INSTRUCTIONS BELOW ON HOW TO ACCOMPLISH THIS AND THEN HOLDING DOWN THE START PUSHBUTTON UNTIL THE TIMER SHOWS PPPP WHICH IS PRACTICE MODE THE PUSHBUTTON SHOULD BE RELEASED UNTIL THE DISPLAY SHOWS 0000 AND THEN HELD AGAIN UNTIL THE TIMER DISPLAY SHOWS SSSS WHICH INDICATES THE SLAVE MODE FOR FURTHER DETAILS REFER TO THE TIMER USER MANUAL Line Out Volume Power Slave Start Silent Swi Voice sw2 SwW3 Practice SW4 Competition Controller ES Quick Draw Electronics FIGURE 1 CONTROLLER LEGENDS SYSTEM Power LINE OUT START Start SLAVE BUTTON Competition Controller CABLE TO NEXT TIMER Y adapter Y adapter AC Power Supply Timer Setup with Competition Controller Figure 2 Setup MODES SILENT MODE THE SILENT MODE IS SELECTED BY PUSHING THE TOGGLE SWITCH ALL THE WAY DOWN WHEN IN THIS MODE THE CONTROLLER PUTS OUT A START COMMAND TO THE TIMERS AFTER A RANDOM DELAY OF 0 TO 3 SECONDS FROM THE RELEASE OF THE START PUSHBUTTON IF THE TIMERS ARE IN THE SLAVE MODE THEY WILL START A DELAY TIMER OF 2 SECONDS IN LENGTH AFTER THE 2 SECONDS THE TIMER WILL START COUNTING AND THE LIGHTS WILL ILLUMINATE THE TOTAL DELAY TIME IS THE SUM OF THE CONTROLLER DELAY AND THE TIMER DELAY WHICH CAN BE FROM 2 TO 5 SECONDS VOICE MODE THE VOICE MODE IS SELECTED BY PUTTING THE TOGGLE SWITCH INTO TH

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instruções HMI sl Fresamento - Service, Support  2 Años - U.S. Robotics  SmartKey User Manual v12.0  UPT - Series Ultracast User Manual  アドバンスドアームボード 取扱説明書  E6 Series User Manual  HD-SDI/SDI To HDMI Video and Audio Converter User Manual  sop12. bed mattress - Matrix Cleaning Systems    User`s Manual - Inventor Air Conditioners  

Copyright © All rights reserved.
Failed to retrieve file