Home
User`s Manual
Contents
1. The WAN interface be configured as PPPoE This type of connection is usually used for a DSL service and requires a username and password to connect EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 WAN Settings Reset Internet Connection Type Select PPPoE from the drop down list MTU The Maximum Transmission Unit MTU is a parameter that determines the largest packet size in bytes that the router will send to the WAN If LAN devices send larger packets the router will break them into smaller packets Ideally you should set this to match the MTU of the connection to your ISP Typical values are 1500 bytes for an Ethernet connection and 1492 bytes for a PPPoE connection If the router s MTU is set too high packets will be fragmented downstream If the router s MTU is set too low the router will fragment packets unnecessarily and in extreme cases may be unable to establish some connections In either case network performance can suffer Login Specify the user name which is provided by your ISP Password Specify the password which is provided by your ISP and then verify it once again in the next field Service Name Specify the name of the ISP Type Select a reconnection type Keep Alive A connection to the Internet is always maintained Connect on Demand You have to open up the Web based management interface and click the Connect button manually any time that you wish to conne
2. Wireless Mode Depending on the type of wireless clients that are connected to the network you may select B G or B G mixed If you are not sure about which clients will be accessing the wireless networks it is recommended that you select B G mixed for the best performance 550 The SSID is a unique named shared amongst all the points of the wireless network The SSID must be identical on all points of the wireless network and cannot exceed 32 characters You may specify an SSID or select one from the Site Survey Site Survey Click on the Site Survey button in order to scan the 2 4GHz frequency for devices that broadcast their SSID Click on the BSSID link to connect to the Access Point Click on the Refresh button to re scan the frequency Site Survey 2 4GHz Site Survey Infrastructure Ad_hoc BSSID 550 Channel Signal Type Security Network Mode 00 e0 4c 81 86 21 DinoNet 86 dBm B WEP 4 00 13 17 7c 61 43 SMC G 105 dBm G NONE A 64 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 7 5 2 Wireless Security Wireless Security Home Reset sewa 7 5 2 1 Wireless Security WEP Security Mode Select WEP from the drop down list if your wireless network uses WEP encryption WEP is an acronym for Wired Equivalent Privacy and is a security protocol that provides the same level of security for wireless networks as for a wired network Home Reset z 1 hao
3. EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 4 3 1 System Properties Click on the System Properties link under the System drop down menu This page allows you to switch the operating mode of the device as well as specify a name and select the operating region System Properties Home Reset Device Name Access Point O O O o Please Select a Country Code Device Name Specify name for the device this is not the SSID Country Region Select a country from the drop down list Operating Mode Select and operating mode Configuration for each operating mode is described in their respective chapters Click on the Apply button to save the changes 4 3 2 IP Settings Click on the IP Settings link under the System drop down menu This page allows you to configure the device with a static IP address or a DHCP client IP Settings Home Reset Network Setting Select Obtain an IP address automatically DHCP radio button if the Access Point is connected to a DHCP server This will allow the Access Point to pass IP addresses to the clients associated with it You may select Specify an IP Address radio button if you would like the device to use a static IP address In this case you would be required to specify an IP address subnet mask and default gateway IP address P Address Specify an IP address IP Subnet Mask Specify the subnet mask for the IP address Default Gateway Specif
4. EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 7 2 2 DHCPClient Table Click on the DHCP Client Table link under the Status drop down menu This page displays the current status of all DHCP clients including IP and expires information DHCP Client List Home Reset MAC addr RB pire 5 0 7 2 3 Connection Status Click on the Connection Status link under the Status drop down menu This page displays the current status of the network including network type SSID BSSID connection status wireless mode current channel security data rate noise level and signal strength Connection Status Home _ Reset Wireless WAN EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 7 2 4 System Log Click on the System Log link under the Status drop down menu The device automatically logs records events of possible interest in its internal memory If there is not enough internal memory for all events logs of older events are deleted but logs of the latest events are retained System Log Home Reset Show log type All Hd Local Log is disabled L Refresh U Clear 57 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 7 3 System Click on the System link on the navigation drop down menu You will then see System Properties setting which is described below 7 3 1 System Properties Click on the System Properties link under the System drop d
5. System Information section IP address Subnet Mask and Default Gateway are displayed in the LAN Setting section In the Wireless Settings section Operation Mode Wireless Mode Channel Frequency MSSID with security Spanning Tree and Distance setting are displayed Home z B z i o 4 5 E ARAR EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 4 2 2 Wireless Client List Click on the Wireless Client List link under the Status drop down menu This page displays the list of Clients that are associated to the Access Point MAC addresses and signal strength for each client is displayed Click on the Refresh button to refresh the client list Client List Home Reset MAC Addr RSSI dBm Refresh 4 2 3 System Log Click on the System Log link under the Status drop down menu The device automatically logs records events of possible interest in its internal memory If there is not enough internal memory for all events logs of older events are deleted but logs of the latest events are retained System Log Home Reset Show log type Ail Local Log is disabled F w J 0 3 Refresh Clear 4 3 System Click on the System link on the navigation drop down menu You will then see three options System Properties IP Settings and Spanning Tree Settings Each option is described in detail below 15
6. Click on the Factory Default Settings button to reset the device to the default settings Please wait while the device restart and then access the device using the default IP address 192 168 1 1 System Rebooting Rebooting Please wait Click here when is ready 5 5 4 Firmware Upgrade Click on the Upgrade Firmware link under the Management menu This page is used to upgrade the firmware on the device Make sure that downloaded the appropriate firmware from your vendor Firmware Upgrade Home Reset Current firmware version 1 0 39 Locate and select the upgrade file from your hard disk HESS ese Upgrade Click on the Browse button and then select the appropriate firmware and then click on the Upgrade button Note The upgrade process may take about 1 minute to complete Do not power off the device during this process as it may crash the device and make it unusable The device will restart automatically once the upgrade is complete 39 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 5 5 5 Time Settings Click on the Time Settings link under the Management menu This page allows you to configure the time on the device You may do this manually or by connecting to a NTP server Time Settings Home Reset Manually Set Date and Time Specify the date and time Automatically Get Date and Time Select the time zone from the drop down list and then specify the IP addr
7. 02 EnGenius Disabled Disabled 1 Km 29 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 5 2 Status Click on the Status link on the navigation drop down menu You will then see three options Main Connection Status and System Log Each option is described in detail below 5 2 1 Main Click on the Main link under the Status drop down menu The status that is displayed corresponds with the operating mode that is selected Information such as device name firmware version MAC address country and current time are displayed in the System Information section IP address subnet mask default gateway and DHCP client are displayed in the LAN Settings section In the Current Wireless Settings section the operation mode wireless mode channel frequency SSID security and distance are displayed Main Home Reset System Information 5 2 2 Connection Status Click on the Connection Status link under the Status drop down menu This page displays the current status of the network including network type SSID BSSID connection status wireless mode current channel security data rate noise level and signal strength 30 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Connection Status Home Reset 5 2 3 System Log Click on the System Log link under the Status drop down menu The device automatically logs records events of possible interest in its inter
8. Authentication Type Select an authentication method Options available are Open Key Shared Key An open system allows any client to authenticate as long as it conforms to any MAC address filter policies that may have been set All authentication packets are transmitted without encryption Shared Key sends an unencrypted challenge text string to any device attempting to communicate with the Access Point The device requesting authentication encrypts the challenge text and sends it back to the Access Point If the challenge text is encrypted correctly the Access Point allows the requesting device to authenticate It is recommended to select Auto if you are not sure which authentication type is used Input Type Select Hex or ASCII from the drop down list Key Length Select a key format from the drop down list 64bit hex keys require 10 characters where as 128 bit keys require 26 characters A hex key is defined as a number between 0 through 9 and letter between A through F and a through f 65 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Default Key You may use up to four different keys for four different networks Select the current key that will be used Key 1 4 You may enter four different WEP keys Click on the Apply button to save the changes 7 5 2 2 Wireless Security WPA PSK WPA2 PSK Security Mode Select WPA PSK or WPA2 PSK from the drop down list if your wireless network uses WPA pre shared key Wire
9. Date Aug 24 2008 Jul 28 2009 New Feature and Functions Included for firmware v1 0 39 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 1 Introduction EOC1650 is a revolutionary product consists of conciseness quality and flexibility It comes with 7dBi internal antenna and upgradable SMA interface provides a customizable interface for enhanced network coverage Attached suction cup allows quick installation on window or smooth surface Operation mode provides Access Point Client Bridge WDS Bridge Client Router and high bandwidth up to 54Mbps It features high transmitted output power and high receivable sensitivity High output power and high sensitivity extends range and coverage to reduce the roaming between Access Points to ensure a stable wireless connection and reduce the expense of equipment It supports distance control ranges from 1km to 30km and RSSI indicator which enables the best transmitted and received signals for traffic communication User can choose a suitable antenna for flexible application This product comes with PoE injector for building in outdoor environment easily To protect wireless connectivity EOC1650 encrypt wireless transmissions through 64 128 bit WEP data encryption and also supports WPA WPA2 The MAC address filter lets you select exactly which stations should have access to your network In addition the User Isolation function can protect the private network betw
10. General Authentication Advanced Connect using E Intel 8255x based PCI Ethernet Adapl This connection uses the following items El Client For Microsoft Networks File and Printer Sharing For Microsoft Networks dal aos Packet Scheduler Internet Protocol TCP IP Install Uninstall Description Transmission Control Protacol Intermet Protocol The default Wide area network protocol that provides communication across diverse interconnected networks C Show icon in notification area when connected Notify me when this connection has limited er no connectivity 10 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Select Internet Protocol TCP IP and then click on the Properties button This will allow you to configure the TCP IP settings of your PC Notebook Internet Protocol TCP IP Properties e General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings Obtain an IP address automatically Use the following IP address IP address 182 168 1 10 Subnet mask 255 255 255 0 Default gateway Use the following DNS server addresses Preferred DNS server Alternate DNS server Select Use the following IP Address radio button and then enter the IP address and subnet mask Ensure that the IP address and
11. L2TP Pass Through iM IPSec Pass Through Apply Can cel PPTP Pass Through Place a check in this box if you would like to enable this pass through PPTP is a protocol set of communication rules that allows corporations to extend their own corporate network through private tunnels 63 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 2TP Pass Through Place a check in this box if you would like to enable this pass through Layer 2 Tunneling Protocol is a transport protocol that enables tunneling through the Internet for the establishment of virtual private networks PSec Pass Through Place a check in this box if you would like to enable this pass through IPSec is a VPN protocol used to implement secure exchange of packets at the IP layer Click on the Apply button to save the changes 7 5 Wireless Click on the Wireless link on the navigation drop down menu You will then see three options wireless network wireless security and wireless advanced settings Each option is described below 7 5 1 Wireless Network The Wireless Network page allows you to configure the wireless mode channel SSID and security settings Wireless Network Home Reset Wireless Mode 802 11b g Mixed 2GHz 54Mbps Specify the static SSID m EnGenius 1 to 32 characters SSID Or press the button to search for any available WLAN Service Site Survey Prefer BSSID Apply Cancel
12. Place the unit in an appropriate location after conducting a site survey Plug one end of the Ethernet cable into the Network port of the PoE injector and another end into your PC Notebook 3 Plug one end of another Ethernet cable to AP Bridge port of the PoE injector and the other end into you cable DSL modem Internet 4 Insert the DC inlet of the power adapter into the 24V port of the PoE injector and the other end into the power socket on the wall This diagram depicts the hardware configuration Power Adapter EOC1650 VA 24V DC IN PC NB Switch 1 Cable DSL Modem Ethernet Ethernet 2 2 Hardware Description The images below depict the front and rear panel of the unit Front Panel Rear Panel dre m EnGenius EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 2 3 Mounting Kits The images below depict the standard mounting kits Pole Mount Wall Mount Window Mount 2 4 IP Address Configuration This device can be configured as a Access Point Client Bridge WDS Bridge Client Router The default IP address of the device is 192 168 1 1 And in order to log into this device you must first configure the TCP IP settings of your PC Notebook 1 In the control panel double click Network Connections and then double click on the connection of your Network Interface Card NIC You will then see the following screen Local Area Connection Properties
13. Subnet Mask Default Gateway DHCP Client Current Wireless Settings Operation Mode Wireless Mode Channel Frequency Spanning Tree Protocol Distance Refresh Home Reset Access Point 00 02 6f 57 87 0a 00 02 6f 57 87 0b N A Sat Jan 1 00 11 37 UTC 2000 1 0 39 192 168 1 1 255 255 255 0 0 0 0 0 Disabled WDS Bridge IEEE 802 11b g Mixed 2 412GHz channel 01 Disabled 1 Km 42 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 6 2 Status Click on the Status link on the navigation drop down menu You will then see three options Main WDS Link Status and System Log Each option is described in detail below 6 2 1 Main Click on the Main link under the Status drop down menu The status that is displayed corresponds with the operating mode that is selected Information such as Device Name Ethernet MAC Address Wireless MAC Address Country Current Time and Firmware are displayed in the System Information section IP address Subnet Mask Default Gateway and DHCP Client are displayed in the LAN Settings section In the Current Wireless Settings section the Operation Mode Wireless Mode Channel Frequency Spanning Tree Protocol and Distance are displayed Main ime ea System Information 43 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 6 2 2 WDS Link Status Click on the WDS Link Status link under the Status drop down menu Th
14. a list of events that are triggered on the Ethernet and Wireless interface This log can be referred when an unknown error occurs on the system or when a report needs to be sent to the technical support department for debugging purposes Log Home Reset Syslog s Da UogServeriP Address fo ufo Local log aa Syslog Choose to enable or disable the system log Log Server IP Address Specify the IP address of the server that will receive the system log Local Log Choose to enable or disable the local log Click on the Apply button to save the changes 7 6 7 Diagnostics Click on the Diagnostics link under the Management menu In this page user can let unit to ping other network equipment And user also can monitor a route from unit to your target Diagnostics Home Reset Ping Test Parameters s K s ia ls Traceroute Test Parameters Start Traceroute 71 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Ping Test Parameters User can input Target IP Ping Size and Ping Quantity of other network device which connected you want And then you can find the ping condition after click Start Ping Traceroute Test Parameters This function help user to monitor a network trace User can input IP or domain name on Traceroute target 72 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Appendix A FCC Interference Statement Federal Communication Commission Interferen
15. by your ISP Password Specify the password which is provided by your ISP and then verify it once again in the next field Type Select a reconnection type Keep Alive A connection to the Internet is always maintained Connect on Demand You have to open up the Web based management O gt NO EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 interface and click the Connect button manually any time that you wish to connect to the Internet Domain Name Service Select Get Automatically from ISP if the ISP will provide the DNS address if not select Use these DNS servers and specify the primary and secondary DNS server IP address Click on the Apply button to save the changes 7 4 2 LAN Settings Click on the LAN Settings link under the Router drop down menu This page allows you to configure the LAN interface as IP address IP subnet mask and WINS server IP When you enable Use Router As DHCP Server specify the IP address from starting to ending LAN Settings EL G LAN IP Setup IP Address 19 15 l IP Subnet Mask gt 25 WINS Server IP Bo Bo iM Use Router As DHCP Server Starting IP Address noB H Ending IP Address 19 25 Apply Cancel 7 4 3 VPN Pass Through Click on the VPN Pass Through link under the Router drop down menu This page allows you to enable the pass through feature VPN Pass Through Home Reset W PPTP Pass Through
16. interference that may cause undesired operation IMPORTANT NOTE FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator amp your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter 13 Multi Function Gigabit Wireless N Client Bridge Version 1 0 Appendix B IC Statement Industry Canada statement This device complies with RSS 210 of the Industry Canada Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation IMPORTANT NOTE Radiation Exposure Statement This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20cm between the radiator amp your body This device has been designed to operate with an antenna having a maximum gain of 5 dBi Antenna having a higher gain is strictly prohibited per regulations of Industry Canada The required antenna impedance is 50 ohms 74
17. server that will receive the system log Local Log Choose to enable or disable the local log Click on the Apply button to save the changes 4 5 8 Diagnostics Click on the Diagnostics link under the Management menu In this page user can let unit to ping other network equipment And user also can monitor a route from unit to your target 27 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Diagnostics Home Reset Ping Test Parameters L MMC Byte S 2h EA A S S 2 LU Number of Pings Traceroute Test Parameters Start Traceroute Ping Test Parameters User can input Target IP Ping Size and Ping Quantity of other network device which connected you want And then you can find the ping condition after click Start Ping Traceroute Test Parameters This function help user to monitor a network trace User can input IP or domain name on Traceroute target 28 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 5 Client Bridge Operating Mode 5 1 Logging In configure the device through the web browser enter the IP address of the device default 192 168 1 1 into the address bar of the web browser and press Enter Make sure that the device and your computers are configured on the same subnet Refer to Chapter 2 in order to configure the IP address of your computer After connecting to the I
18. subnet mask are on the same subnet as the device For Example PC IP address 192 168 1 10 PC subnet mask 255 255 255 0 Click on the OK button to close this window and once again to close LAN properties window 11 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 3 Switching Between Operating Modes This device can operate in three modes Access Point Client Bridge WDS Bridge and Client Router This chapter will describe how to switch between operating modes 3 1 Logging In configure the device through the web browser enter the IP address of the device default 192 168 1 1 into the address bar of the web browser and press Enter Make sure that the device and your computer are configured on the same subnet Refer to Chapter 2 in order to configure the IP address of your computer After connecting to the IP address the web browser will display the login page Specify admin for both the user name and password J Page Load Error Mozilla Firefox File Edit View History Bookmarks Tools Help C X a 192 188 1 1 Authentication Required amp J Enter username and password Far http f 192 168 1 1 User Mame admin f Cancel After logging in you will see the graphical user interface of the device Click on the System Properties link under the System navigation drop down menu System Properties Home Reset Device Name Access Point 1 to 32 characters Countr
19. the device by selecting a value from the drop down list This feature can be helpful in restricting the coverage area of the wireless network Fragment Length Packets over the specified size will be fragmented in order to improve performance on noisy networks RTS CTS Threshold Packets over the specified size will use the RTS CTS mechanism to maintain performance in noisy networks and preventing hidden nodes from degrading the performance Protection Mode If your wireless network is using both 802 11b and 802 g devices then it is recommended to enable this feature so that the 802 11b devices will not degrade the performance of 802 11g devices Enable wireless Quality of Service Distance 1 30km Specify a distance between 1 and 30Km Channel Bandwidth For different application you can select 20M Hz 10MHz or 5MHz channel bandwidth Click on the Apply button to save the changes Co EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 4 5 Management Click on the Management link on the navigation drop down menu You will then see seven options administration SNMP settings backup restore settings firmware upgrade time settings and log Each option is described below 4 5 1 Administration Click on the Administration link under the Management menu This option allows you to create a user name and password for the device By default this device is configured without a user name and passwor
20. 0 Firmware Version 1 0 39 LAN Settings IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 DHCP Server Enabled WAN Settings MAC Address 00 02 6f 57 87 0b Connection Type Static IP Interface down IP Address IP Subnet Mask 0 0 0 0 Current Wireless Settings Operation Mode Client Router Wireless Mode IEEE 802 11b g Mixed Channel Frequency 2 442GHz channel 07 Wireless Network Name SSID EnGenius Security Disabled EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Click on the Status link on the navigation drop down menu You will then see four options Main DHCP Client Table Connection Status and System Log Each option is described in detail below 7 2 1 Main Click on the Main link under the Status drop down menu The status that is displayed corresponds with the operating mode that is selected Information such as Device Name MAC Address Country Current and Firmware Version are displayed in the System Information section IP Address Subnet Mask Default Gateway and DHCP Server condition are displayed in the LAN Settings section In the WAN Settings MAC Address Connection Type Interface and IP Address Subnet Mask are displayed The Current Wireless Settings section displays Operation Mode Wireless Mode Channel Frequency SSID Security and Distance control Ec Www LAN Settings WAN Settings E E T D Es C1
21. 1 0 39 Locate and select the upgrade file from your hard disk Upgrade Click on the Browse button and then select the appropriate firmware and then click on the Upgrade button Note The upgrade process may take about 1 minute to complete Do not power off the device during this process as it may crash the device and make it unusable The device will restart automatically once the upgrade is complete 4 5 6 Time Settings Click on the Time Settings link under the Management menu This page allows you to configure the time on the device You may do this manually or by connecting to a NTP server 26 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Time Settings Home Reset Foniy Manually Set Date and Time Specify the date and time Automatically Get Date and Time Select the time zone from the drop down list and then specify the IP address of the NTP server Click on the Apply button to save the changes 4 5 7 Log Click on the Log link under the Management menu The Log page displays list of events that are triggered on the Ethernet and Wireless interface This log can be referred when an unknown error occurs on the system or when a report needs to be sent to the technical support department for debugging purposes Log Home Reset Syslog Emm Local log I Syslog Choose to enable or disable the system log Log Server IP Address Specify the IP address of the
22. 26 55 DMESERINGS nisi te etus SSD S SS a Rau L to 26 4 5 7 ERE EE TU UE 27 4 5 8 DIAGN0 CEN ERR RTL TTE 27 5 CLIENT BRIDGE OPERATING MODE u u u a S u Sun n iQ 29 5 1 Eelcic c PPRRENPS 29 5 2 ceci ESL MAL E MM AEI RM LI IAM I AUN S 30 52 1 MAN 230s m 30 5 22 STATU 30 5 23 SYSIEPMTOS uay tS u l D Sh 31 5 3 css T m aa u unu a a aD S i w a es 32 59 1 SYSTEM PROPERTIES Be UR ed a Ran utt baa epe ird di aa knee a 32 5 3 2 IOP T Isa n e M o 32 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 5 9 9 SPANNING TREE SETTINGS ooo cites qaod abies a d tau E ne b vedete bes bibo e reve n CORE O 33 5 4 WIRES i S SZ m ba au S a Su tae Me 33 Dd L AWIBEBRESSNEDIWORCS S Z e ERES EI m u ex rey Fred 33 542 WIRELESSSECURIIYu 34 5 4 3 WIRELESS ADVANCED SETTINGS u u uuu ibas tenda ead ttd up 36 5 5 MANAGEMENT 37 5 5 1 ADMINISTRATION Z 37 5 952 SNMP SETTINGS E 38 5 5 3 BACKUP RESTORE SETTINGS RESET TO FACTORY DEFAULT SETTINGS 30 5 5 4 FIRMWARE
23. 5 3 SNMP Settings Click on the SNMP Settings link under the Management menu This option allows you to assign the contact details location and community name and trap settings for SNMP This is a networking management protocol used to monitor networl attached devices SNMP allows messages called protocol data units to be sent to various parts of a network Upon receiving these messages SNMP compatible devices called agents return data stored in their Management Information Bases SNMP Settings EL j SNMP Enable Disable Enable Disable Contact Location Community Name Read Only public Community Name Read Write private Trap Destination IP Address Trap Destination Community Name Bo Bo public i Apply Cancel SNMP Enable Disable Choose to enable or disable the SNMP feature Contact Specify the contact details of the device Location Specify the location of the device Read Only Community Name Specify the password for access the SNMP community for read only access Read Write Community Name Specify the password for access to the SNMP community with read write access Send SNMP Trap Specify the IP address of the computer that will receive the SNMP traps Trap Community Name Specify the password for the SNMP trap community Click on the Apply button to save the changes 4 5 4 Backup Restore settings Reset to factory default settings Click on the Backu
24. 6 3 2 IP Settings Click on the IP Settings link under the System drop down menu This page allows you to configure the device with a static IP address or a DHCP client 4 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 IP Network Setting Select Obtain IP address automatically DHCP radio button if the Access Point is connected to a DHCP server This will allow the Access Point to pass IP addresses to the clients associated with it You may select Specify an IP Address radio button if you would like the device to use a static IP address In this case you would be required to specify an IP address subnet mask and default gateway IP address P Address Specify an IP address IP Subnet Mask Specify the subnet mask for the IP address Default Gateway Specify the IP address of the default gateway Click on the Apply button to save the changes 6 3 3 Spanning Tree Settings Click on the Spanning Tree link under the System drop down menu Spanning Tree Protocol is a link management protocol that provides path redundancy while preventing undesirable loops in the network Spanning Tree Settings EL Spanning Tree Status O On 9 Off Bridge Hello Time 1 seconds 1 10 Bridge Max Age 20 seconds 6 40 Bridge Forward Delay 4 seconds 4 30 Priority 32758 seconds 0 65535 a Apply 3 Cancel Spanning Tree Status Choose to enable or disable the spanning tree feature Bridg
25. 802 1x IEEE802 1x Authenticator 2 Station isolation Management 2 gt Firmware Upgrade Upgrading firmware via web browser setting are reserved after upgrade Reset amp Backup Reset to factory default User can export all setting into a file via WEB gt Ping amp Trace Route Built in PING function amp Trace Route function Web GUI gt MIB MIB I MIB II RFC1213 Private MIB gt SNMP V1 V2c 1 2 Package Contents Open the package carefully and make sure that none of the items listed below are missing Do not discard the packing materials in case of return the unit must be shipped in its original package 1 802 11b g Long range AP CB EOC1650 1 PoE injector EPE 1212 1 Power Adaptor 1 CD with User s Manual 1 Quick Installation Guide QIG 1 Metal Strap 2 Special Screw Set 1 5dBi Dipole Antenna 2 Suction Cup Y Y Y Y Y Y Y Y YV 1 3 System Requirements The following are the minimum system requirements in order to configure the device gt PC AT compatible computer with an Ethernet interface gt Operating system that supports HTTP web browser 1 4 Applications The wireless LAN products are easy to install and highly efficient The following list describes some of the many applications made possible through the power and flexibility of wireless LANs a Difficult to wire environments There are many situations where wires cannot be laid easily Historic buildings older buildings open areas an
26. DS Bridge Operating Mode 6 1 Logging In To configure the device through the web browser enter the IP address of the device default 192 168 1 1 into the address bar of the web browser and press Enter Make sure that the device and your computers are configured on the same subnet Refer to Chapter 2 in order to configure the IP address of your computer After connecting to the IP address web browser will display the login page Specify admin for both the user name and password After logging in you will graphical user interface GUI of the device The navigation drop down menu on left o is divided into four sections 1 Status Displays the overall status WDS link status and system log 2 System This menu includes the system properties IP and Spanning Tree settings 2 Page Load Error Mozilla Firefox File Edit History Bookmarks Tools Help x ei 192 168 1 1 Authentication Required Enter username and password for http 192 168 1 1 User Name admin Password eeeee I Cancel 3 Wireless This menu includes network setting WDS link setting WDS security and advanced setting 4 Management This menu includes the admin setup SNMP firmware upgrade time setting diagnostics and save restore backup System Information Device Name Ethernet MAC Address Wireless MAC Address Country Current Time Firmware Version LAN Settings IP Address
27. EnGenius EOC1650 Wireless Access Point amp Client Bridge User s Manual Version 2 0 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Table of Contents 1 INTRODUCTION u P M 6 1 1 FEATURES sucess 6 1 2 PACKAGE CONTENTS odes Ue 7 1 3 SYSTEM REGUIRBEMENTS2 uy u Rau Gua tendu tos dd te Coe ct Deu ss EC 7 1 4 PAP PLICATIONS escaso AURI UON mu E 7 2 UNDERSTANDING THE HARDWARIE 9 2 1 HARDWABEATNSDTAEDATION du uu eati ues be ama es cii 9 2 2 HARDWARE DESCRIPTION zio aito au d ipm E A E PU DM Ur I Ide Me aM I Dp DEL S sss 9 2 3 MOUNTING KITS epit i ide u DV hs quia iba Go Ed 10 2 4 IP ADDRESS CONFIGURA HORN Giai oce a Ves er rhe tute reset ooo ove aod ed emi dna beca Rd co 10 3 SWITCHING BETWEEN OPERATING MODEIS 12 3 1 LOGGING IN 12 4 ACCESS POINT OPERATING MODE vnda Ee Pe po pred u PEa Pv Re NEN YE PEN Tw va PEE Sob go are UNS v bU Pep Doo gan 13 4 1 LOGGING IN E Z M 13 4 2 STATUS S
28. HCP 59 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 WAN Settings O Internet IP Address Internet Connection Type Select the Static IP from the drop down list Account Name Specify an account name if your ISP has provided you with one Domain Name Specify a domain name if the ISP has provided you with one MTU The Maximum Transmission Unit MTU is a parameter that determines the largest packet size in bytes that the router will send to the WAN If LAN devices send larger packets the router will break them into smaller packets Ideally you should set this to match the MTU of the connection to your ISP Typical values are 1500 bytes for an Ethernet connection and 1492 bytes for a PPPoE connection If the router s MTU is set too high packets will be fragmented downstream If the router s MTU is set too low the router will fragment packets unnecessarily and in extreme cases may be unable to establish some connections In either case network performance can suffer IP Address Specify the IP address for this device which is assigned by your ISP Subnet Mask Specify the subnet mask for this IP address which is assigned by your ISP Gateway IP Address Specify the IP address of the default gateway which is assigned by your ISP Domain Name Service Specify the primary and secondary DNS server IP address Click on the Apply button to save the changes 7 4 1 3 PPPoE
29. K Mixed from the drop down list if your wireless network uses WPA pre shared key gt gt Encryption Select TKIP or AES from the drop down list if your wireless network uses this encryption WPA Wi Fi Protected Access was designed to improve upon the security features of WEP Wired Equivalent Privacy The technology is designed to work with existing Wi Fi products that have been enabled with WEP WPA provides improved data encryption through the Temporal Integrity Protocol TKIP which scrambles the keys using a hashing algorithm and by adding an integrity checking feature which makes sure that keys haven t been tampered with gt gt Passphrase Specify a passphrase that is shared amongst the Access Points and clients gt gt Group Key Update Interval Specify the number of seconds after which the Access Point will probe the client for the passphrase gt gt Click on the Save button to save the changes gt Wireless Security Security Mode WPA WPA2 WPA Mixed 20 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 SSID Profile Wireless Setting Wireless Security r gt gt Security Mode Select WPA WPA2 or WPA Mixed from the drop down list if your wireless network uses WPA WPA Wi Fi Protected Access was designed to improve upon the security features of WEP Wired Equivalent Privacy The technology is designed to work with existing Wi Fi products that have been enabl
30. P address the web browser will display the login page Specify admin for both the user name and password After logging in you will graphical user interface GUI of the device The navigation drop down menu on left is divided into four sections 1 Status Displays the overall status connection status and system log 2 System This menu includes the system properties IP and Spanning Tree settings 3 Wireless This menu includes network security and advanced settings _ Page Load Error Mozilla Firefox File Edit View Bookmarks Tools Help Authentication Required History 192 168 1 1 Enter username and password For http 192 168 1 1 User Name admin Password eeeee i Cancel 4 Management This menu includes the admin setup SNMP firmware upgrade time settings diagnostics and save restore backup System Information Device Name Ethernet MAC Address Wireless MAC Address Country Current Time Firmware Version LAN Settings IP Address Subnet Mask Default Gateway DHCP Client Current Wireless Settings Operation Mode Wireless Mode Channel Frequency Wireless Network Name SSID Security Spanning Tree Protocol Distance Refresh Home Reset Access Point 00 02 6f 57 87 0a 00 02 6f 57 87 0b N A Sat Jan 1 00 09 06 UTC 2000 1 0 39 192 168 1 1 255 255 255 0 0 0 0 0 Disabled Client Bridge IEEE 802 11b g Mixed 2 417GHz channel
31. Reset Administrator Name admin Password Confirm Password se Remote Access Remote Management Enable 9 Disable Remote Upgrade Enable Disable Remote Management Port soso _ Apply Cancel Name Specify a user name into the first field Password Specify a password into this field and then re type the password into the Confirm Password field Remote Management Choose to enable or disable remote management Remote Upgrade Choose to enable or disable remote firmware upgrade Remote Management Port Specify a port for remote management For example if you specify 8080 then you will need to specify lt P address gt lt port gt 192 168 1 1 8080 to connect to the web interface of the device Click on the Apply button to save the changes 7 6 2 SNMP Settings Click on the SNMP Settings link under the Management menu This option allows you to assign the contact details location and community name and trap settings for SNMP This is a networking management protocol used to monitor network attached devices SNMP allows messages called protocol data units to be sent to various parts of a network Upon receiving these messages SNMP compatible devices called agents return data stored in their Management Information Bases 68 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 SNMP Settings Home Reset Gommages O 3 HC S SNMP Enable Disable Choo
32. TORE SETTINGS RESET TO FACTORY DEFAULT SETTINGS a 51 6 5 4 FIRMWARE UPGRADE variances cianatantocencer edet ad aa iba e caste nda aaa a DS bei us id ad 51 OSS PUIG Se THINGS S yl Q un uu Ros OT E D E Sas De na 52 6 5 6 Ko aras y um nu 52 6 5 7 DIAGNOS I C RIRs 53 CLIENT ROUTER OPERATING MODI 54 7 1 LOGGING IN ep asas 54 7 2 T 54 7 2 1 WITH s munai ana 55 7 2 2 DHCP CHENT TABE u aap kana aqasha aaa a DPI Sitat daa ta M beo e SNMP 56 7 2 3 CONNECTION STATS yuaya LE Q pe uD are ua ama A uos Md Madre mM C aa da ires 56 v SOV clle CHUTE UT Km mE TUN 2 7 3 dA heo iM Mr EU MA hades 58 1 SEM PROPERTIES t Z l iei voe orca Cea set A UNES D DAD 58 7 4 ROUT S zas RR ONE UNUS 58 Z4 WANSIYIKO uuu m ascen rd ua T su 58 7 4 1 1 WAN la 59 7 4 1 2 WAN ICIP 59 7 4 1 3 WAN DPD0 S u See m ed a cen ae Mee Suka D dah eats 60 7 4 1 4 MAN SD Tas eae nu umayup awata Lave o a ere may Neem eC mmr Ce ed ne E eae 62 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 7 4 2 LANSEPI COBRE aI SA ayu t s pakan anay 63 743 WPNOPASSCTHROUGH Ru uuu um u ou gratie en
33. UPGRADE dto adici MM rp IMMER M MM M MU MI s 30 5 58 55 AME SENINOS esset Rohre ope tul sa orca bon a EA ES ber N 40 5 5 6 unata ttes EE NM AL MM MOS Micra apes AA MAC 40 5 5 7 DIAGNOSTIC Saane cet ae lcs cect ac meer htc hie ta saa arse oan NS ie ce tc tr A ru Meas 40 WDS BRIDGE OPERATING a u i I A i uu u eaaa aa 42 6 1 LOGGING Norte nanum cT 42 6 2 AT 2222 tsk ee bur cra ma d eot edens hay kaspa tutan aa rt Cod sat sin cena 43 6 2 1 VIA A S u Zim E US D ME dt ete tanned a a Au Sas maana pr u makata saat aie 43 622 WDSDEINKSIAKIU X 2 Z ta totins oru u S unum Ou te 44 SS MEME cR CREER UT EROS 44 6 3 SYN s TRO HONO Hn RR MF PR 45 6 31 SYSTEM PROPERTIES d n lana as aan G viv tob a 45 6 3 2 IL SET II C E en uenenum ap ntl rU aq aus a 45 633 SPANNING TREE SETTINGS XR n ms D m bon us a S u mae aus 46 6 4 VA TIRES Secs y EU T a UTC 46 6 4 1 WIREEESS NED WORK uuu ut Zap 47 602 MWDSDENCSEDHNGS od dtd tu SEM ER ol a Msi uc ete P T avers eases 47 BAS ANDS SEC URI ouibus etie nnd vatis conet quii aei ot Moers 48 64 4 WIRELESS ADVANCED SETTINGS 2 u u L aeta oneri uuu h db oda ED a ute ma bd teo e 48 6 5 MANAGEMENT Usi acetic u aZ p uta e tate ur tbi ten wid nu 49 6541 JADMINISIRATIONus R kt Au Past Rue Buah 50 MEE e ISER RICETTE ecc ec Ec 50 6 5 3 BACKUP RES
34. Wireless Advanced Settings Home E Data Rate Transmit Power 20 dBm b Fragment Length 256 2346 2346 bytes RTSI CTS Threshold 1 2346 2346 bytes Protection Mode Disable J WMM Disable Channel Bandwidth 20MHz Distance 1 30km l1 km Apply Cancel Data Rate If you would like to force a data rate you may select one from the drop down list However for best performance it is recommended to use the Auto setting Transmit Power You may have the different application distance of the device by selecting value from the drop down list This feature can be helpful in restricting the coverage area of the wireless network Fragment Packets over the specified size will be fragmented in order to improve performance on noisy networks RTS Threshold Packets over the specified size will use the RTS CTS mechanism to maintain performance in noisy networks and preventing hidden nodes from degrading the performance Protection Mode If your wireless network is using both 802 11b and 802 g devices then it is recommended to enable this feature so that the 802 11b devices will not degrade the performance of 802 11g devices Distance 1 30km Specify a distance between 1 and 30Km Click on the Apply button to save the changes 5 5 Management Click on the Management link on the navigation drop down menu You will then see six options administration SNMP settings bac
35. cation Specify the location of the device Read Only Community Name Specify the password for access the SNMP community for read only access Read Write Community Name Specify the password for access to the SNMP community with read write access Send SNMP Trap Specify the IP address of the computer that will receive the SNMP traps Trap Community Name Specify the password for the SNMP trap community Click on the Apply button to save the changes 38 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 5 5 3 Backup Restore settings Reset to factory default settings Click on the Backup Restore Setting link under the Management menu This option is used to save the current settings of the device in a file on your local disk or load settings on to the device from a local disk This feature is very handy for administrators who have several devices that need to be configured with the same settings Backup Restore Settings osse Backup Save A Copy of Current Settings Lo T Restore Saved Settings from A File SESE eae AS k Restore xss Factory Default Revert to Factory Default Settings po Save a copy of the current settings Click on the Backup button to save the current configuration Restore saved settings from a file Once a file has been backed up you may restore it by clicking on the Browse button to select the file and then the Restore button Revert to factory default settings
36. ccess Point Client Bridge Version 2 0 Read Only Community Name Specify the password for access the SNMP community for read only access Read Write Community Name Specify the password for access to the SNMP community with read write access Trap Destination IP Address Specify the IP address of the computer that will receive the SNMP traps Trap Destination Community Name Specify the password for the SNMP trap community Click on the Apply button to save the changes 6 5 3 Backup Restore settings Reset to factory default settings Click on the Backup Restore Setting link under the Management menu This option is used to save the current settings of the device in a file on your local disk or load settings on to the device from a local disk This feature is very handy for administrators who have several devices that need to be configured with the same settings Backup Restore Settings Home Reset Backup Save A Copy of Current Settings bod p Restore Saved Settings from A File THE RSE e Revert to Factory Default Settings Factory Default Save a copy of the current settings Click on the Backup button to save the current configuration Restore saved settings from a file Once a file has been backed up you may restore it by clicking on the Browse button to select the file and then the Restore button Revert to factory default settings Click on the Factory Default Settings button to re
37. ce Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures A Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including
38. ct to the Internet Domain Name Service Select Get Automatically from ISP if the ISP will provide the DNS address if not select Use these DNS servers and specify the primary and secondary DNS server IP address Click on the Apply button to save the changes 61 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 7 4 1 4 WAN PPTP The WAN interface can be configured as PPTP This type of connection is usually used for a DSL service and requires a username and password to connect WAN Settings LHeme Reto Options wu Ge sJ PPTP Options Internet Connection Type Select PPPoE from the drop down list MTU The Maximum Transmission Unit MTU is a parameter that determines the largest packet size in bytes that the router will send to the WAN If LAN devices send larger packets the router will break them into smaller packets Ideally you should set this to match the MTU of the connection to your ISP Typical values are 1500 bytes for an Ethernet connection and 1492 bytes for a PPPoE connection If the router s MTU is set too high packets will be fragmented downstream If the router s MTU is set too low the router will fragment packets unnecessarily and in extreme cases may be unable to establish some connections In either case network performance can suffer PPTP Options Specify IP address subnet mask default gateway and PPTP server Username Specify the user name which is provided
39. cuentan v odd Eran Iba OE a mapa amam Rien Cort D uas Lob n UOS CUM INE 14 4 2 1 MAIN c r 14 422 JANMIRELESS CEIENT PST u u EE aO Rute o pasaqa ta RE ead a sia val pda o M E e tdeo 15 UC MEM SVS REN OG uu SD k FE 15 4 3 SY SIE IA arte ataman anaku ava Tr Tr TT 15 43 1 SYSTEM PROPERTIES sa d daa at tata tua oa di Up aei dea ter a ERE ukana 16 4 3 2 PPS S TR au au au w ma Sua u u uusha Dau a Sama s 16 4 3 3 SPANNING TREE SETIIN GOSE l hast nb a Lud 17 4 4 eme HH TNT 17 4 4 1 WIRELESS NETWORK M 17 243 2 AMIREEESSTIVIAG EIETBR oce Rae rebas a Pte kaqku Mte e Ob knee het Ute 2l 443 MWDSENISEEBHINGS randi imo onte ba PR a aUe eb PER e tata tel eat rv uc pu vp obruo nio 22 4 4 4 WIRELESS ADVANCED SETTINGS aiii oeil ate pu on reo debe PUR dei Eee ae RAN RU Le TUUS 27 4 5 WIANAGEMENJT Iu paces cibus opa Md ada vba dta FUE 24 15 1 ADMINISTRATION S DD L A ET Suyu EL A mayu ua dM MEC 24 4 5 2 IWIANAGEMENT MAIN societe sac la ea ved yaqqana 24 49 3 CSINIVIPSETHNOS duse IX eed ie aka wasa Qu has de nde dice sio edu d 25 4 5 4 4 BACKUP RESTORE SETTINGS RESET TO FACTORY DEFAULT SETTINGS a r 25 4 5 5 FIRMWARE UPGRADE up uyu tien abet ure ct exu Matte dea ena SA n ie wasa sh eine aaa
40. d across busy streets make the installation of LANs either impossible or very expensive b Temporary workgroups Consider situations in parks athletic arenas exhibition centers disaster recovery temporary offices and construction sites where one wants a temporary WLAN 7 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 c a e f g h established and removed The ability to access real time information Doctors nurses point of sale employees and warehouse workers can access real time information while dealing with patients serving customers and processing information Frequently changed environments Show rooms meeting rooms retail stores and manufacturing sites where frequently rearrange the workplace Small Office and Home Office SOHO networks SOHO users need a cost effective easy and quick installation of a small network Wireless extensions to Ethernet networks Network managers in dynamic environments can minimize the overhead caused by moves extensions to networks and other changes with wireless LANs Wired LAN backup Network managers implement wireless LANs to provide backup for mission critical applications running on wired networks Training Educational facilities Training sites at corporations and students at universities use wireless connectivity to ease access to information information exchanges and learning 2 Understanding the Hardware 2 1 Hardware Installation 1
41. d admin For security reasons it is highly recommended that you create a new user name and password Administration Home Reset Administrator Name admin Password pem Confirm Password quem Apply Cancel Name Specify a user name into the first field Password Specify a password into this field and then re type the password into the Confirm Password field Click on the Apply button to save the changes 4 5 2 Management VLAN Click on the Management VLAN link under the Management menu This option allows you to specify VLAN ID From 1 to 4095 Caution If you reconfigure the Management VLAN ID you may lose connectivity to the access point Verify the switch and DHCP server can support the reconfigured VLAN ID and then reconnect to new IP address Management VLAN Settings Caution it you reconfigure the Management VLAN ID you may lose connectivity to the access point Verify that the switch and DHCP server can support the reconfigured VLAN ID and then re connect to the new IP address No VLAN tag Management VLAN ID 3 Specified VLAN ID must be in the range 1 4095 Apply Cancel 3 24 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Name Specify a user name into the first field Password Specify a password into this field and then re type the password into the Confirm Password field Click on the Apply button to save the changes 4
42. d u tutu ae Sas ua SS Nd um 63 7 5 WIR Nac EE EM TO m hauran us ca Rw Ba DNE 64 WIRELESS NETWORK L oto etre Pee U L oed reple eae E CE TS sd urbis Uni eat bar 64 43 5 2 WIRELESS SECUR NV GG dudo dC PRESE dex I dim dede pa Urbs Su tota haud dium ist c Io DU 65 7 5 2 1 WIRELESS se TR NORTE nhau h Q Q 65 752 2 WIRELESS SECURITY WPA PSK WPA2 PSK 66 53 WIRELESS ADVANCED SETTINGS E a MTS VER 66 7 6 WIANAGEMENJT DEC DRM EE aa I M tulo P dare vetat Pa a M NR E HN E 67 Z O L NDMINISERATGON SS SDK DM M ME A DR MM EU MM Me 68 L62 SNMPESETING carman TUTTO bahaya 68 7 6 3 BACKUP RESTORE SETTINGS RESET TO FACTORY DEFAULT SETTINGS 69 720 4 FEFIRRWARBEDDGRABE y E EZ LUE 70 PDs MME ETING Z Z OU UU 70 7 6 6 Hoc Res ety MdL EINE dye y OI HD pons IN IONE cte 71 7 6 7 DIAGNOSTIC ont DE Ea Pm E EP I nc eo Id IU E D 71 APPENDIX FCC INTERFERENCE STATEMENTI A 73 APPENDIX B IC STATEMENT csssscssssneccessassisasvecssessabauansecsuudaswnsesncecvevevdnsedansvsedeveunstncannuevcuieasvegesusnenieespoenseese 74 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Revision History Version
43. dress s Get Automatically From ISP Use These DNS Servers Primary DNS lo Bo Bo Secondary DNS lo Bo Bo Apply Cancel Internet Connection Type Select the DHCP from the drop down list Account Name Specify an account name if your ISP has provided you with one Domain Name Specify a domain name if the ISP has provided you with one MTU The Maximum Transmission Unit MTU is a parameter that determines the largest packet size in bytes that the router will send to the WAN If LAN devices send larger packets the router will break them into smaller packets Ideally you should set this to match the MTU of the connection to your ISP Typical values are 1500 bytes for an Ethernet connection and 1492 bytes for a PPPoE connection If the router s MTU is set too high packets will be fragmented downstream If the router s MTU is set too low the router will fragment packets unnecessarily and in extreme cases may be unable to establish some connections In either case network performance can suffer Domain Name Service Select Get Automatically from ISP if the ISP will provide the DNS address if not select Use these DNS servers and specify the primary and secondary DNS server IP address Click on the Apply button to save the changes 7 4 1 2 WAN Static IP The WAN interface can be configured as Static IP address In this type of connection your ISP provides you with a dedicated IP address which does not change as D
44. e Hello Time Specify the number of seconds for the hello time Bridge Max Age Specify the number of seconds for the max age Bridge Forward Delay Specify the number of seconds for the bridge forward delay Priority Specify the number of seconds for the priority Click on the Apply button to save the changes 6 4 Wireless Click on the Wireless link on the navigation drop down menu You will then see four options Wireless Network WDS Link Settings WDS Security and Wireless Advanced Settings Each section is described in detail below 46 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 6 4 1 Wireless Network The Wireless Network page allows you to configure the wireless mode channel SSID and security settings Wireless Network Home Reset omen Wireless Mode Depending on the type of wireless clients that are connected to the network you may select B G or B G mixed If you are not sure about which clients will be accessing the wireless networks it is recommended that you select B G mixed for the best performance Channel Frequency Select a channel from the drop down list The channels available are based on the country s regulation 6 4 2 WDS Link Settings Click on the WDS Link Settings link under the Wireless drop down menu This page allows you to setting your WDS device link up to 16 units WDS Link Settings Home Reset Disable 15 Disable 13 Di
45. e network all other clients will be blocked On the other hand selected Deny MAC in the List only the listed MAC addresses will be blocked from accessing the network all other clients will have access to the network MAC Address Enter the MAC address This table lists the blocked or allowed MAC addresses you may delete selected MAC address or delete all the addresses from the table by clicking on the Delete button Click on the Apply button to save the changes 4 4 3 WDS Link Settings Click on the WDS Link Settings link under the Wireless menu On this page you can set the WDS link to connect to another WDS AP or WDS Bridge The Maximum connection is up to 8 units WDS Link Settings Home Reset ENEENN O 4 4 4 Wireless Advanced Settings Click on the Wireless Advanced Settings link On this page you can configure the advanced settings to tweak the performance of your wireless network Options available are data rate transmit power fragmentation threshold RTS threshold protection mode and distance rN N EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Wireless Advanced Settings Home 20 dam 5 Disable Disable Data Rate If you would like to force a rate you may select one from the drop down list However for best performance it is recommended to use the Auto setting Transmit Power You may have the different application distance of
46. ed with WEP WPA provides improved data encryption through the Temporal Integrity Protocol TKIP which scrambles the keys using a hashing algorithm and by adding an integrity checking feature which makes sure that keys haven t been tampered with gt gt Encryption Select TKIP or AES from the drop down list if your wireless network uses this encryption gt gt RADIUS Server Enter the IP address of the RADIUS server gt gt RADIUS Port Enter the port number of the RADIUS server The default is usually 1812 gt gt RADIUS Secret Enter the shared password of the RADIUS server gt gt Group Key Update Interval Specify the number of seconds after which the Access Point will probe the client for the secret gt gt Click on the Save button to save the changes Profile SSID Isolation When you select this function to enable unit can isolate all profiles SSIDs from each other using VLAN standard 4 4 2 Wireless MAC Filter Click on the Wireless MAC Filter link under the Wireless menu On this page you can filter the MAC address by allowing or blocking access the network 21 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Wireless MAC Filter Heme Reset ACL Mode Apply ACL Access Control Mode You may choose to Disable Allow Listed or Deny Listed MAC addresses from associating with the network By selecting Allow MAC in the List only the address listed in the table will have access to th
47. een client users The attractive design high performance and array of features make EOC1650 an optimal wireless solution choice for your residence and office 1 1 Features Wireless gt 2 4GHz It works in 2 4GHz frequency spectrum gt High output power Transmit high output power programmable for different country selections gt High Data Rate High speed transmitting rate up to 54Mbps support large payload gt Multifunction application Access Point Client Bridge Client Router WDS Function Long range transmitting Transmit power control and distance control ACK timeout gt Narrow Bandwidth Provide 5MHz 10MHz 20MHz bandwidth selection Signal Strength Display RF signal strength status shown LEDs of colors making network build up easier LED indicators have the best transmit and receive signal for traffic communication gt Multiple SSID 4 SSID supported Each SSID can set itself wireless or WAN access setting gt QoS WMM Enhance performance and density Networking gt PPPoE Point to Point Protocol over Ethernet at Client Router mode This function will keep trying when failed or disconnected gt PPTP Point to Point Tunneling Protocol PPTP is a method for implementing virtual private networks gt VPN Pass Through EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Security gt 802 111 WEP WPA WPA2 Encryption support TKIP AES gt MAC address functions MAC address filter AP mode gt
48. em allows any client to authenticate as long as it conforms to any MAC address filter policies that may have been set All authentication packets are transmitted without encryption Shared Key sends an unencrypted challenge text string to any device attempting to communicate with the Access Point The device requesting authentication encrypts the challenge text and sends it back to the Access Point If the challenge text is encrypted correctly the Access Point allows the requesting device to authenticate It is recommended to select Auto if you are not sure which authentication type is used gt gt Input Type Select Hex or ASCII from the drop down list gt gt Key Length Select a key format from the drop down list 64bit hex keys require 10 characters where as 128 bit keys require 26 characters A hex key is defined as a number between 0 through 9 and letter between A through F and a through f gt gt Default Key You may use up to four different keys for four different networks Select the current key that will be used gt gt Key 1 4 You may enter four different WEP keys gt gt Click on the Save button to save the changes gt Wireless Security Security Mode WPA PSK WPA2 PSK WPA PSK Mixed 19 EnGenius EOC1650 Wireless Access Point Client Bridge SSID Profile EnGenius l passphrase 1 3 J a Version 2 0 Hr 5 gt gt Security Mode Select WPA PSK WPA2 PSK WPA PS
49. ent Bridge Version 2 0 Wireless Network Home Reset Wireless Mode Depending on the type of wireless clients that are connected to the network you may select B G or B G mixed If you are not sure about which clients will be accessing the wireless networks it is recommended that you select B G mixed for the best performance Channel Frequency Select a channel from the drop down list The channels available are based on the country s regulation Current Profiles User can setup SSID configuration in this item EOC1650 supports 4 SSIDs user can decide to use how many SSID via Enable or not When click Edit button you can setup detail include SSID VLAN ID and Security Mode SSID Profile Wireless Setting gt Wireless Security Security Mode WEP 18 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 SSID Profile Wireless Setting Wireless Security X 40 64 bit 10 hex digits or 5 ASCII char 104 128 bit 26 hex digits or 13 ASCII char 128 152 bit 32 hex digits or 16 ASCII char gt gt Security Mode Select WEP from the drop down list if your wireless network uses WEP encryption WEP is an acronym for Wired Equivalent Privacy and is a security protocol that provides the same level of security for wireless networks as for a wired network gt gt Authentication Type Select an authentication method Options available are Open Key Shared Key An open syst
50. erent keys for four different networks Select the current key that will be used Key 1 4 You may enter four different WEP keys Click on the Apply button to save the changes Wireless Security WPA2 PSK Security Mode Select WPA2 PSK from the drop down list if your wireless network uses WPA pre shared key 35 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Wireless Security Home Reset Changing the wireless security settings may cause this wireless client to associate with a different one This may temporarily disrupt your configuration session Security Mode Encryption TKIP Passphrase 8 to 63 characters or 64 Hexadecimal characters Apply Cancel Encryption Select TKIP or AES from the drop down list if your wireless network uses this encryption WPA Wi Fi Protected Access was designed to improve upon the security features of WEP Wired Equivalent Privacy The technology is designed to work with existing Wi Fi products that have been enabled with WEP WPA provides improved data encryption through the Temporal Integrity Protocol TKIP which scrambles the keys using a hashing algorithm and by adding an integrity checking feature which makes sure that keys haven t been tampered with Passphrase Specify a passphrase that is shared amongst the Access Points and clients Click on the Apply button to save the changes Wireless Security WPA PSK Security Mode Select WPA PSK fr
51. ess of the NTP server Click on the Apply button to save the changes 5 5 6 Log Click on the Log link under the Management menu The Log page displays list of events that triggered on the Ethernet and Wireless interface This log can be referred when an unknown error occurs on the system or when a report needs to be sent to the technical support department for debugging purposes Log Home Reset Syslog Bem y Local log C oe Syslog Choose to enable or disable the system log Log Server IP Address Specify the IP address of the server that will receive the system log Local Log Choose to enable or disable the local log Click on the Apply button to save the changes 5 5 7 Diagnostics Click on the Diagnostics link under the Management menu In this page user can let unit to ping other network equipment And user also can monitor a route from unit to your target 40 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Ping Test Parameters Traceroute Test Parameters Ping Test Parameters User can input Target IP Ping Size and Ping Quantity of other network device which connected you want And then you can find the ping condition after click Start Ping Traceroute Test Parameters This function help user to monitor a network trace User can input IP or domain name on Traceroute target 41 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 6 W
52. ettings button to reset the device to the default settings Please wait while the device restart and then access the device using the default IP address 192 168 1 1 System Rebooting Rebooting Please wait ET Click here when AP is ready 7 6 4 Firmware Upgrade Click on the Upgrade Firmware link under the Management menu This page is used to upgrade the firmware on the device Make sure that downloaded the appropriate firmware from your vendor Firmware Upgrade Home Reset Upgrade Click on the Browse button and then select the appropriate firmware and then click on the Upgrade button Note The upgrade process may take about 1 minute to complete Do not power off the device during this process as it may crash the device and make it unusable The device will restart automatically once the upgrade is complete 7 6 5 Time Settings Click on the Time Settings link under the Management menu This page allows you to configure the time on the device You may do this manually or by connecting to a NTP server Time Settings Home Reset 70 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Manually Set Date and Time Specify the date and time Automatically Get Date and Time Select the time zone from the drop down list and then specify the IP address of the NTP server Click on the Apply button to save the changes 7 6 6 Log Click on the Log link under the Management menu The Log page displays
53. is page displays the current status of the WDS Link including Station ID MAC address Status RSSI Received Signal Strength Indicator WDS Link Status Home Reset Station ID MAC Adress Status RSSI dBm Refresh 6 2 3 System Log Click on the System Log link under the Status drop down menu The device automatically logs records events of possible interest in its internal memory If there is not enough internal memory for all events logs of older events are deleted but logs of the latest events are retained System Log Home Reset Show log type Ail Local Log is disabled Refresh Clear 44 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 6 3 System Click on the System link on the navigation drop down menu You will then see System Properties IP Settings and Spanning Tree Settings 6 3 1 System Properties Click the System Properties link under the System drop down menu This page allows you to switch the operating mode of the device as well as specify a name and select the operating region System Properties M Please Select a Country Code Apply Device Name Specify a name for the device this is not the SSID Country Region Select a country from the drop down list Operating Mode Select and operating mode Configuration for each operating mode is described in their respective chapters Click on the Apply button to save the changes
54. kup restore settings firmware upgrade time settings and log Each option is described below 5 5 1 Administration Click on the Administration link under the Management menu This option allows you to create a user name and password for the device By default this device is configured without a user name and password admin For security reasons it is highly recommended that you create a new user name and password 37 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Administration Home Reset Administrator Name Specify a user name into the first field Password Specify a password into this field and then re type the password into the Confirm Password field Click on the Apply button to save the changes 5 5 2 SNMP Settings Click on the SNMP Settings link under the Management menu This option allows you to assign the contact details location and community name and trap settings for SNMP This is a networking management protocol used to monitor network attached devices SNMP allows messages called protocol data units to be sent to various parts of a network Upon receiving these messages SNMP compatible devices called agents return data stored in their Management Information Bases SNMP Settings Home Reset cena D i O Commun name gesa O 3 aa I m e SNMP Enable Disable Choose to enable or disable the SNMP feature Contact Specify the contact details of the device Lo
55. ld protection mode and distance 48 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Wireless Advanced Settings Home Reset Auto G 2346 Disable 3 Data Rate If you would like to force data rate you may select one from the drop down list However for best performance it is recommended to use the Auto setting Transmit Power You may have the different application distance of the device by selecting a value from the drop down list This feature can be helpful in restricting the coverage area of the wireless network Fragment Length Packets over the specified size will be fragmented in order to improve performance on noisy networks RTS CTS Threshold Packets over the specified size will use the RTS CTS mechanism to maintain performance in noisy networks and preventing hidden nodes from degrading the performance Protection Mode If your wireless network is using both 802 11b and 802 g devices then it is recommended to enable this feature so that the 802 11b devices will not degrade the performance of 802 11g devices WMM Enable wireless Quality of Service Distance 1 30km Specify a distance between 1 and 30Km Click on the Apply button to save the changes 6 5 Management Click on the Management link on the navigation drop down menu You wil see seven options Administration SNMP Settings Backup Restore Settings Firmware Upgrade Time Settings Log and Diagnostics Each opti
56. less Security Home Reset Apply Encryption Select TKIP or AES from the drop down list if your wireless network uses this encryption WPA Wi Fi Protected Access was designed to improve upon the security features of WEP Wired Equivalent Privacy The technology is designed to work with existing Wi Fi products that have been enabled with WEP WPA provides improved data encryption through the Temporal Integrity Protocol TKIP which scrambles the keys using a hashing algorithm and by adding an integrity checking feature which makes sure that keys haven t been tampered with Passphrase Specify a passphrase that is shared amongst the Access Points and clients Click on the Apply button to save the changes 7 5 3 Wireless Advanced Settings Click on the Wireless Advanced Settings link On this page you can configure the advanced settings to tweak the performance of your wireless network Options available are data rate transmit power fragmentation threshold RTS threshold protection mode and distance O O EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Wireless Advanced Settings Home 20 dBm 2345 Disable Disable 20MHz H Data Rate If you would like to force a data rate you may select one from the drop down list However for best performance it is recommended to use the Auto setting Transmit Power You may have the different application distance of the device by
57. n the Wireless link on the navigation drop down menu You will then see three options wireless network wireless security and wireless advanced settings Each option is described below 5 4 1 Wireless Network The Wireless Network page allows you to configure the wireless mode channel SSID and security settings 33 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Wireless Network Home Reset Wireless Mode Depending on the type of wireless clients that are connected to the network you may select B G or B G mixed If you are not sure about which clients will be accessing the wireless networks it is recommended that you select B G mixed for the best performance SSID The SSID is a unique named shared amongst all the points of the wireless network The SSID must be identical on all points of the wireless network and cannot exceed 32 characters You may specify an SSID or select one from the Site Survey Site Survey Click on the Site Survey button in order to scan the 2 4GHz frequency for devices that broadcast their SSID Click on the BSSID link to connect to the Access Point Click on the Refresh button to re scan the frequency Site Survey 2 4GHz Site Survey infrastructure Ad hoc 5 4 2 Wireless Security You can chang th wireless security settings may cause this wireless client to associate with a different one This may temporarlly disrupt your configuration session Wireless Sec
58. nal memory If there is not enough internal memory for all events logs of older events are deleted but logs of the latest events are retained oe _ 500 e Local Log is disabled 31 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 5 3 System Click on the System link on the navigation drop down menu You will then see three options System Properties IP Settings and Spanning Tree Settings Each option is described in detail below 5 3 1 System Properties Click on the System Properties link under the System drop down menu This page allows you to switch the operating mode of the device as well as specify a name and select the operating region System Properties Home Reset Device Name Access Point O Please Select a Country Code Device Name Specify name for the device this is not the SSID Country Region Select a country from the drop down list Operating Mode Select and operating mode Configuration for each operating mode is described in their respective chapters Click on the Apply button to save the changes 5 3 2 IP Settings Click on the IP Settings link under the System drop down menu This page allows you to configure the device with a static IP address or a DHCP client IP Settings Home Reset Network Setting Select Obtain an IP address automatically DHCP radio button if the Access Point is connected to a DHCP server This will allow
59. om the drop down list if your wireless network uses WPA pre shared key Wireless Security Home Reset Changing the wireless security settings may cause this wireless client to associate with a different one This may temporarily disrupt your configuration session Securty Mode Encryption TKIP J T l 8 to 63 characters or 64 Hexadecimal Passphrase characters Apply Cancel Encryption Select TKIP or AES from the drop down list if your wireless network uses this encryption WPA Wi Fi Protected Access was designed to improve upon the security features of WEP Wired Equivalent Privacy The technology is designed to work with existing Wi Fi products that have been enabled with WEP WPA provides improved data encryption through the Temporal Integrity Protocol TKIP which scrambles the keys using a hashing algorithm and by adding an integrity checking feature which makes sure that keys haven t been tampered with Passphrase Specify a passphrase that is shared amongst the Access Points and clients Click on the Apply button to save the changes 5 4 3 Wireless Advanced Settings Click on the Wireless Advanced Settings link On this page you can configure the advanced settings to tweak the performance of your wireless network Options available are data rate transmit power fragmentation threshold RTS threshold protection mode and distance 36 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0
60. on is described below 49 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 6 5 1 Administration Click on the Administration link under the Management menu This option allows you to create a user name and password for the device By default this device is configured without a user name and password admin For security reasons it is highly recommended that you create a new user name and password Administration Home Reset Administrator Name Specify a user name into the first field Password Specify a password into this field and then re type the password into the Confirm Password field Click on the Apply button to save the changes 6 5 2 SNMP Settings Click on the SNMP Settings link under the Management menu This option allows you to assign the contact details location and community name and trap settings for SNMP This is a networking management protocol used to monitor network attached devices SNMP allows messages called protocol data units to be sent to various parts of a network Upon receiving these messages SNMP compatible devices called agents return data stored in their Management Information Bases SNMP Settings Home Reset B K SNMP Enable Disable Choose to enable or disable the SNMP feature Contact Specify the contact details of the device Location Specify the location of the device 5 EnGenius EOC1650 Wireless A
61. own menu This page allows you to switch the operating mode of the device as well as specify a name and select the operating region System Properties Home Reset Device Name Access Point 1 to 32 characters Country Region Please Select a Country Code O Access Point Operation Mode aoe Client Router Apply Cancel Device Name Specify a name for the device this is not the SSID Country Region Select a country from the drop down list Operating Mode Select operating mode Configuration for each operating mode is described in their respective chapters Click on the Apply button to save the changes 7 4 Router Click on the Router link on the navigation drop down menu You will then see three options WAN settings LAN settings and VPN Pass Through Each section is described in detail below 7 4 1 WAN Settings Click on the WAN Settings link under the Router drop down menu This page allows you to configure the WAN interface as DHCP Static IP PPPoE or PPTP 58 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 7 4 1 1 WAN DHCP The WAN interface can be configured as a DHCP Client in which the ISP provides the IP address to the device This is also known as Dynamic IP WAN Settings EL ES Internet Connection Type Options Account Name required none Domain Name if required none MTU Auto E 1500 Domain Name Server DNS Ad
62. p Restore Setting link under the Management menu This option is used to save the current settings of the device in a file on your local disk or load settings on to the device from a local disk This feature is very handy for administrators who have several devices that need to be configured with the same settings 25 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Backup Restore Settings Home Reset Backup Save A Copy of Current Settings lk Restore Saved Settings from A File EES pe Revert to Factory Default Settings k Factory Default _ Save a copy of the current settings Click on the Backup button to save the current configuration Restore saved settings from a file Once a file has been backed up you may restore it by clicking on the Browse button to select the file and then the Restore button Revert to factory default settings Click on the Factory Default Settings button to reset the device to the default settings Please wait while the device restart and then access the device using the default IP address 192 168 1 1 System Rebooting Rebooting Please wait Click here when AP is ready 4 5 5 Firmware Upgrade Click on the Upgrade Firmware link under the Management menu This page is used to upgrade the firmware on the device Make sure that downloaded the appropriate firmware from your vendor Firmware Upgrade Home Reset Current firmware version
63. sable Disable Disable Disable Cancel 47 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 MAC Address you can input the MAC address of WDS device which you want to link Mode Enable to connect and Disable to disconnect Click on the Apply button to save the changes 6 4 3 WDS Security WDS Security Home Reset Security None WEP Key Apply Can cel Security Mode Select WEP from the drop down list if your wireless network uses WEP encryption WEP is an acronym for Wired Equivalent Privacy and is a security protocol that provides the same level of security for wireless networks as for a wired network WDS Security Hom Rm Security WEP WEP Key 407 64 bit 10 hex digits 104 128 hit 26 hex digits 128 152 hit 32 hex digits Apply Cancel WEP Key Select a key format from the drop down list 64bit hex keys require 10 characters where as 128 bit keys require 26 characters and 152 bits keys require 32 characters A hex key is defined as a number between 0 through 9 and letter between A through F and a through f Click on the Apply button to save the changes 6 4 4 Wireless Advanced Settings Click on the Wireless Advanced Settings link On this page you can configure the advanced settings to tweak the performance of your wireless network Options available are data rate transmit power fragmentation threshold RTS thresho
64. se to enable or disable the SNMP feature Contact Specify the contact details of the device Location Specify the location of the device Read Only Community Name Specify the password for access the SNMP community for read only access Read Write Community Name Specify the password for access to the SNMP community with read write access Trap Destination IP Address Specify the IP address of the computer that will receive the SNMP traps Trap Destination Community Name Specify the password for the SNMP trap community Click on the Apply button to save the changes 7 6 3 Backup Restore settings Reset to factory default settings Click on the Backup Restore Setting link under the Management menu This option is used to save the current settings of the device in a file on your local disk or load settings on to the device from a local disk This feature is very handy for administrators who have several devices that need to be configured with the same settings Backup Restore Settings Home Reset O ED 0 gt Save a copy of the current settings Click on the Backup button to save the current configuration 69 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Restore saved settings from a file Once a file has been backed up you may restore it by clicking on the Browse button to select the file and then the Restore button Revert to factory default settings Click on the Factory Default S
65. selecting a value from the drop down list This feature can be helpful in restricting the coverage area of the wireless network Fragment Packets over the specified size will be fragmented in order to improve performance on noisy networks RTS Threshold Packets over the specified size will use the RTS CTS mechanism to maintain performance in noisy networks and preventing hidden nodes from degrading the performance Protection Mode If your wireless network is using both 802 11b and 802 g devices then it is recommended to enable this feature so that the 802 11b devices will not degrade the performance of 802 11g devices Enable wireless Quality of Service Distance 1 30km Specify a distance between 1 and 30Km Click on the Apply button to save the changes 7 6 Management Click on the Management link on the navigation drop down menu You will then see six options administration SNMP settings backup restore settings firmware upgrade time settings log and Diagnostics Each option is described below O N EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 7 6 1 Administration Click on the Administration link under the Management menu This option allows you to create a user name and password for the device By default this device is configured without a user name and password admin For security reasons it is highly recommended that you create a new user name and password Administration Home
66. ser enter the IP address of the device default 192 168 1 1 into the address bar of the web browser and press Enter Make sure that the device and your computers are configured on the same subnet Refer to Chapter 2 in order to configure the IP address of your computer After connecting to the IP address the web browser will display the login page Specify admin for both the user name and password After logging in you will graphical user interface GUI of the device The navigation drop down menu on left is divided into four sections 1 Status Displays the overall status DHCP client table connection status and system log System This menu includes the system properties Router This includes WAN LAN and VPN settings Wireless This menu includes wireless network security and advanced settings Management This menu includes the admin setup SNMP settings firmware upgrade save restore backup time setting and diagnostics 2 Page Load Error Mozilla Firefox File Edit View History Bookmarks Tools Help 192 168 1 1 Authentication Required Enter username and password For http 192 168 1 1 User Name adrnin Password e Cancel A EnGenius 7 2 Status System Information Device Name Access Point Ethernet MAC Address 00 02 6f 57 87 0a Wireless MAC Address 00 02 6f 57 87 0b Country NJA Current Time Sat Jan 1 00 13 37 UTC 200
67. set the device to the default settings Please wait while the device restart and then access the device using the default IP address 192 168 1 1 System Rebooting Rebooting Please wait Click here when is ready 6 5 4 Firmware Upgrade Click on the Upgrade Firmware link under the Management menu This page is used to upgrade the firmware on the device Make sure that downloaded the appropriate firmware from your vendor 51 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Firmware Upgrade Home Reset Upgrade Click on the Browse button and then select the appropriate firmware and then click on the Upgrade button Note The upgrade process may take about 1 minute to complete Do not power off the device during this process as it may crash the device and make it unusable The device will restart automatically once the upgrade is complete 6 5 5 Time Settings Click on the Time Settings link under the Management menu This page allows you to configure the time on the device You may do this manually or by connecting to a NTP server Time Settings Home Reset 2000 00 00 00 England Manually Set Date and Time Specify the date and time Automatically Get Date and Time Select the time zone from the drop down list and then specify the IP address of the NTP server Click on the Apply button to save the changes 6 5 6 Log Click on the Log link
68. the Access Point to pass IP addresses to the clients associated with it You may select Specify an IP Address radio button if you would like the 32 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 device to use a Static IP address In this case you would be required to specify an IP address subnet mask and default gateway IP address P Address Specify an IP address IP Subnet Mask Specify the subnet mask for the IP address Default Gateway Specify the IP address of the default gateway Click on the Apply button to save the changes 5 3 3 Spanning Tree Settings Click on the Spanning Tree link under the System drop down menu Spanning Tree Protocol is a link management protocol that provides path redundancy while preventing undesirable loops in the network Spanning Tree Settings EL IA Spanning Tree Status O On 2 Off Bridge Hello Time 1 seconds 1 10 Bridge Max Age 2D seconds 6 40 Bridge Forward Delay 4 seconds 4 30 Priority 32768 seconds 0 65535 Spanning Tree Status Choose to enable or disable the spanning tree feature Bridge Hello Time Specify the number of seconds for the hello time Bridge Max Age Specify the number of seconds for the max age Bridge Forward Delay Specify the number of seconds for the bridge forward delay Priority Specify the number of seconds for the priority Click on the Apply button to save the changes 5 4 Wireless Click o
69. u includes the admin setup SNMP firmware upgrade diagnostics time setting and save restore backup eoo http 192 168 1 1 setup cgi 4 gt http 192 168 1 1 setup cgi o CO HE HREM Yahoo Google YouTube 1027 v Pv EnGenius Main Home Reset System Information Device Name Access Point Ethernet MAC Address 00 02 6f 57 87 0a Wireless MAC Address 00 02 6f 57 87 0b Country N A Current Time Sat Jan 1 00 02 59 UTC 2000 Firmware Version 1 0 39 Management VLAN ID Untagged LAN Settings IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Default Gateway 0 0 0 0 DHCP Client Disabled Current Wireless Settings Operation Mode Access Point Wireless Mode IEEE 802 11b g Mixed Channel Frequency 2 412GHz channel 01 Profile Isolation No 1 EnGenius1 Open System No Encryption 1 Profile Settings 2 SSID Security VID 3N A 4 Spanning Tree Protocol Disabled Distance 1Km 13 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 4 2 Status Click on the Status link on the navigation drop down menu You will then see three options Main Wireless Client List and System Log Each option is described in detail below 4 2 1 Main Click on the Main link under the Status drop down menu The status that is displayed corresponds with the operating mode that is selected Information such as Device Name MAC Address Country Current Time and Firmware Version are displayed in the
70. under the Management menu The Log page displays a list of events that are triggered on the Ethernet and Wireless interface This log can be referred when an unknown error occurs on the system or when a report needs to be sent to the technical support department for debugging purposes 52 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Log Home Reset Sysog 0 0 0 00 0 0 0 0 0 0000000000000 INE ae uu Local log Bae Syslog Choose to enable or disable the system log Log Server IP Address Specify the IP address of the server that will receive the system log Local Log Choose to enable or disable the local log Click on the Apply button to save the changes 6 5 7 Diagnostics Click on the Diagnostics link under the Management menu In this page user can let unit to ping other network equipment And user also can monitor a route from unit to your target Diagnostics Home Reset Ping Test Parameters Traceroute Test Parameters Start Traceroute Ping Test Parameters User can input Target IP Ping Size and Ping Quantity of other network device which connected you want And then you can find the ping condition after click Start Ping Traceroute Test Parameters This function help user to monitor a network trace User can input IP or domain name on Traceroute target o3 7 Client Router Operating Mode 7 1 Logging In To configure the device through the web brow
71. urity Home Reset Wireless Security WEP EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 Security Mode Select WEP from the drop down list if your wireless network uses WEP encryption WEP is an acronym for Wired Equivalent Privacy and is a security protocol that provides the same level of security for wireless networks as for a wired network Wireless Security Home Reset Apply Cancel Authentication Type Select an authentication method Options available are Open Key Shared Key An open system allows any client to authenticate as long as it conforms to any MAC address filter policies that may have been set All authentication packets are transmitted without encryption Shared Key sends an unencrypted challenge text string to any device attempting to communicate with the Access Point The device requesting authentication encrypts the challenge text and sends it back to the Access Point If the challenge text is encrypted correctly the Access Point allows the requesting device to authenticate It is recommended to select Auto if you are not sure which authentication type is used Input Type Select Hex or ASCII from the drop down list Key Length Select a key format from the drop down list 64bit hex keys require 10 characters where as 128 bit keys require 26 characters A hex key is defined as a number between 0 through 9 and letter between A through F and a through f Default Key You may use up to four diff
72. y Region Please Select a Country Code Access Point C Client Bridge Operation Mode iz O WDS Bridge C Client Router i Apply Cancel Select operating mode you want from the list Access Point Client Bridge WDS Bridge or Client Router and then click on the Apply button 12 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 4 Access Point Operating Mode 4 1 Logging In configure the device through the web browser enter the IP address of the device default 192 168 1 1 into the address bar of the web browser and press Enter Make sure that the device and your computers are configured on the same subnet Refer to Chapter 2 in order to configure the IP address of your computer After connecting to the IP address the web Bae yee browser will display the login page File Edit View History Bookmarks Tools Help Specify admin for both the user name and B c x D password After logging in you will graphical user interface 0 GUI of the device The navigation drop down Enter username and password For http 192 168 1 1 menu on left is divided into four sections 1 Status Displays the overall status connection Mame status and event log 1 2 System This menu includes the system canca properties IP and Spanning Tree settings Wireless This menu includes network setting MAC filter WDS link advanced and security 4 Management This men
73. y the IP address of the default gateway Click on the Apply button to save the changes 16 EnGenius EOC1650 Wireless Access Point Client Bridge Version 2 0 4 3 3 Spanning Tree Settings Click on the Spanning Tree link under the System drop down menu Spanning Tree Protocol is a link management protocol that provides path redundancy while preventing undesirable loops in the network Spanning Tree Settings EL Spanning Tree Status On 9 Off Bridge Hello Time 1 seconds 1 10 Bridge Max Age 20 seconds 6 40 Bridge Forward Delay 4 seconds 4 30 Priority 32758 seconds 0 65535 Apply Cancel 3 Spanning Tree Status Choose to enable or disable the spanning tree feature Bridge Hello Time Specify the number of seconds for the hello time Bridge Max Age Specify the number of seconds for the max age Bridge Forward Delay Specify the number of seconds for the bridge forward delay Priority Specify the number of seconds for the priority Click on the Apply button to save the changes 4 4 Wireless Click on the Wireless link on the navigation drop down menu You will then see four options wireless network wireless MAC filter WDS link settings and wireless advanced settings Each option is described below 4 4 1 Wireless Network The Wireless Network page allows you to configure the wireless mode channel SSID and security settings 17 EnGenius EOC1650 Wireless Access Point Cli
Download Pdf Manuals
Related Search
Related Contents
Manual del Usuario – DISEÑO de COMPROBATES Livret Utilisateur DECT Grundig ELYA FR Fujitsu PRIMERGY RX100 S5 「発表抄録」(抄録集) - 東京都 南多摩保健医療圏 地域リハビリテーション PI Planner Manuel d`utilisation PI Planner Manuel d`utilisation SDS Series User Manual - MIPS-lab Travel it Easy™ User Guide COCHE RADIO CONTROL RADIO CONTROL CAR SW-1 SNOW MACHINE bulletin 26.qxp - SDE 07, syndicat départemental d`énergies de l Copyright © All rights reserved.