1. Voltage Out Current Out The AVR power is OFF To turn the power on or off select the On or Off button below and then press Set Copyright 2009 Plitron Inc Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units To access AVR software enter user name and password User name admin is factory set and cannot be changed Default Password avr You can change your password Select Set Password AVR Status This screen indicates the overall status of the system showing Voltage In Voltage Out and Current output It also reports if the system is functioning normally or whether there is a fault condition AVR Power Control This screen allows ON or OFF control of the AVR unit Press SET button to implement your selection www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 6 Email Configuration Set Password Torus Power Home Network Configuration Torus Power AVR AVR Setup This page allows the configuration of the AVR s programmable parameters v Shutdown on Low or High line voltage v LCD Backlight Always On LCD Backlight 0 to 255 seconds Time Copyright 2009 Plitron Inc Torus Power AVR AVR Status Email Configuration 1 Please enter the Email Address that the logged data should be sent to Email Configuration p Set Password Network Configuration Switch Power Email Configuration Set P
2. 3 Heed Warnings All warnings on the device and in the operating instructions should be adhered to 4 Follow Instructions All operating and safety instructions should be followed 5 Water amp Moisture The device should never be used in on or near water for risk of fatal shock 6 Ventilation The device should always be located in such a way that it maintains proper ventilation It should never be placed in a built in installation or anywhere that may impede the flow of air through its ventilation slots 7 Heat Never locate the device near heat sources such as radiators floor registers stoves or other heat generating devices 8 Power Cord Protection Power cables should be routed so they are not likely to be stepped on or crushed by items placed on them or against them Special attention should be paid to areas where the plug enters a socket or fused strip and where the cord exits the device 9 Periods Of Non Use The device should be unplugged when not being used for extended periods 10 Dangerous Entry Care should be taken that no foreign objects or liquids fall or are spilled inside the device Please keep the original shipping box and all packing material This will ensure the AVR is protected in future transport In the unlikely event you have a problem and must return it for service you must use the original packing material Ship the AVR only in the original packing material as the unit is not
3. Model Number AVR 16 UK RK AVR 16 UK CB AVR 16 UK CS AVR 8 UK RK AVR 8 UK CB AVR 8 UK CS AVR 4 UK RK AVR 4 UK CB AVR 4 UK CS AVR 16 CE RK AVR 16 CE CB AVR 16 CE CS AVR 8 CE RK AVR 8 CE CB AVR 8 CE CS AVR 4 CE RK AVR 4 CE CB AVR 4 CE CS AVR 16 AUS RK AVR 16 AUS CB AVR 16 AUS CS AVR 8 AUS RK AVR 8 AUS CB AVR 8 AUS CS AVR 4 AUS RK AVR 4 AUS CB AVR 4 AUS CS Owner s Manual 011 Input Voltage Nominal Operating Range 170 270VAC 47 53Hz Operating Range 170 270VAC 47 53Hz Operating Range 170 270VAC 47 53Hz 011 Le Input Inlet Connector Rear Panel IEC 320 C20 IEC 320 C14 IEC 320 C14 IEC 320 C20 IEC 320 C14 IEC 320 C14 IEC 320 C20 IEC 320 C14 IEC 320 C14 AVR Power Conditioners Jie MEO CIES Input Current Limiting 16A Circuit Breaker 160A Front Panel 8A Circuit Breaker 80A Front Panel 4A Circuit Breaker 80A Front Panel 16A Circuit Breaker 160A Front Panel 8A Circuit Breaker 80A Front Panel 4A Circuit Breaker 80A Front Panel 16A Circuit Breaker 160A Front Panel 8A Circuit Breaker 80A Front Panel 4A Circuit Breaker 80A Front Panel ic i Jilc MOQUE Output Connector Rear Panel 6 outlets 13A 250V UK Socket 5 outlets 13A 250V UK Socket 3 outlets 13A 250V UK Socket 8 outlets 16A 250V Ivory Continental European Socket 5 outlets 16A 250V Ivory Continental European Socket 4 outlets 16A 250V Ivory Continental Eu
4. factory default password by pressing the button on the front ofthe AVR unit and HOLDING it down for at least 10 seconds The default password is avr www TorusPower com Rack Mount RK Consumer C REV 11 07 2012 11 12 Page 7 p gt Pu a dD E D Ld dD J eS D a Each AVR unit has a unique MAC Address which is factory assigned Torus Power AVR NO AVR Network Configuration Switch Power This page allows the configuration of the AVR s network settings CAUTION Incorrect settings may cause the AVR to lose network Configuration connectivity Recovery options will be provided on the next page Set Password Enter the new settings for the AVR below The IP address assigned to the AVR is dynamically assigned and is displayed on this screen as well as on the front Torus Power Home Network Configuration e MAC Address IP Address 00 50 C2 B5 D1 36 Host Name AVR v Enable DHCP E Gateway Subnet Mask Primary DNS Secondary DNS Save Config panel LCD of the AVR The AVR can be programmed through the web browser to automatically get an IP address from the network switch or router and this is the default setting and should work on most networks Some networks require each PC or device to use a fixed IP address and the AVR also supports this option Notes 1 The output current Amps displayed on the LCD is the RMS reading of t
5. Electrical Specifications International Models 002 Page 14 Mechanical Specifications International Models 00 c cc Page 14 Rear Panel Layout of International Models 00 erre Page 15 Home Automation Interface cc ecc cc cc cc Page 16 Warranty AAA ss ss ee Page 16 www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 1 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units CAUTION To reduce the risk of electric shock and fire do not remove the cover of this device There are no user serviceable parts inside Please refer all servicing to licensed service technicians CAUTION The international symbol of a lightning bolt inside a triangle is intended to alert the user to uninsulated dangerous voltage within the device s enclosure The international symbol of an exclamation point inside a triangle is intended to alert the user to the presence of important operating maintenance and servicing information in the manual accompanying the device CAUTION To prevent electrical shock match wide blade of plug to wide slot fully insert CAUTION To reduce the risk of electrical shock do not expose this equipment to rain or moisture 1 Read Instructions All safety and operating instructions should be read before operating the device 2 Retain Instructions The safety and operating instructions should be retained for future reference
6. insurable by carriers otherwise Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units 11 Damage Requiring Service The device should be serviced by licensed technicians when e The plug or power supply cord has been damaged e Objects have fallen or liquid has spilled inside the device e The device has been exposed to moisture e The device does not appear to be operating properly or exhibits a marked change in performance e The device has been dropped or the enclosure becomes damaged 12 Service The device should always be serviced by licensed technicians Only replacement parts specified by the manufacturer should be used The use of unauthorized substitutions may result in fire shock or other hazards 13 Do not position the equipment so that it is difficult to operate the disconnecting device power cord 14 If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 15 The power switch should be in the off position when connecting or disconnecting equipment from a Torus Power unit 16 CAUTION Some units can be very heavy please use safe practices when lifting gt 18 kg 39 7 Ib gt 32 kg 70 5 Ib gt 55 kg 121 2 lb www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 2 Power AVR erie DWE ONC one ar Notes and Manug Placement and ventilation Allow 1 dist
7. 0007 d E Available Models e Shock mounted oversized transformer Nominal Operable Output Input Input cect Ranae Series Mode Response Norin American 240V 170V 270V 120V 5V Balanced JE E OKA r 7 r 4 Gus us BO 1204 150 00 5 eV D3 1 e WR7 1 Tlme Note Layout drawing is provided for reference only Torus Power AVR units have no serviceable parts inside Please return unit to manufacturer for repair and service when required Power Transformer Potential nsformer 2 Relay Board 4 Top Tra Potential nsformer 1 o Relay Board 2 Bottom Tra Power ON OFF Switch Circuit Breaker www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 9 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units MAIN CONTROLLER INPUT 120VAC c es E 09 A1 REAR PANEL ASSEMBLY A2 TRANSFORMER ASSEMBLY T1 13B GRN YEL A3 WIRED CHASSIS ASSEMBLY A4 SURGE PROTECTOR ASSEMBLY MAIN CONTROLLER PCB COMM BOARD INPUT 230VAC 230VAC OUTPUTS A1 REAR PANEL ASSEMBLY T1 12B GRN f YEL A2 TRANSFORMER ASSEMBLY A3 WIRED CHASSIS ASSEMBLY A4 SURGE PROTECTOR ASSEMBLY Note Schematic drawings are provided for reference only Torus Power AVR units have no serviceable parts inside Please return unit to manufacturer for repair and service when required www TorusPower com o
8. AVR Series Manual Audio Video Power Isolation Units with Automatic Voltage Regulation Isolate Restore Inspire 17 Consumer Series C Faceplate Available in Black B and Silver S Colours Table of Contents o OSOS Table of Contents sc eee Page 1 Important Safety Instructions ccc t tc ee Page 2 Shipping Carton Packing Material ss teeter t eee e eens Page 2 Torus Power AVR Series Power Conditioners User Notes and Manual Etat ene ee ee a RA AA OR ee ho ee ew ES SC SR oe OR A Page 3 Front Panel Display ee ee ee ee a a a a a a a a a a a aa a a a a a a TA Page 4 Rear Panel Connections and AVR Software ct Page 5 AVR Software Menu Selection ee ee a a a a a a a a a a a a a a a Page 6 7 8 Block Diagram AVR System ee ee ee a a a a a a a a Page Layout sos Page Schematic North American Model ee ee ee ee Page 10 Schematic International Model READER AS AAA AAA Page 10 North American Model Numbers ee ee ee ee EEE EREEEAEEEREE Page 11 International Model Numbers NENA AAA AAA Page 11 Typical front Panel Layout of North American and International Models eorrr Page 12 Electrical Specifications North American Models Page 12 Mechanical Specifications North American Models otto Page 12 Line Cords and Wall Receptacles for North American Models 5686 5656865 bb ees tke bat ee aoe a AAA ee ees Page 13 Rear Panel Layout of North American Models 00 Page 13
9. S CS and AVR 16 AUS CB 16A 250V Ivory Continental European Socket 13A 250V UK Socket a Continental Europe 8A Model Number a a United Kingdom 8A Model Number Ml AVR 8 CE RK AVR 8 CE CS and AVR 8 CE CB AVR 8 UK RK AVR 8 UK CS and AVR 8 UK CB 10A 250V Interpower Socket AUS Accessory Ground Stud Power Inlet IEC320 C14 mu Australian 8A Model Number UN AVR 8 AUS RK AVR 8 AUS CS and AVR 8 AUS CB 16A 250V Ivory Continental European Socket Continental Europe 4A Model Numbers United Kingdom 4A Model Numbers E AVR 4 CERK AVR 4 CE CS and AVR 4 CE CB AVR 4 UK RK AVR 4 UK CS and AVR 4 UK CB 10A 250V Interpower Socket AUS Australian 4A Model Numbers AVR 4 AUS RK AVR 4 AUS CS and AVR 4 AUS CB www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 15 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units Home Automation Interface Ss Serial Port Settings 9600 baud 8 data bits No parity Commands are terminated with the carriage return character 13 decimal Warranty gt Torus Power products are warranted to be free from manufacturing defects for five years from the original date of sale This includes parts labour and return shipping to the first registered owner and all subsequent registered owners Warranty coverage is extended to applicable products registered or having proof of purchase sales invoice etc In the event of a defect o
10. aker trips the switch returns to its off position While Torus Power AVR Units are designed to handle well beyond these limits they must be marked with a Thermal Protection maximum input current that satisfies the requirements Torus AVRs will shut down if internal unit temperature reaches excessive levels gt Ica pecification MO n American Mode Model Number Input Voltage Input Load Current Capability Input Current Nominal Current Rating Limiting 1 2 cycle 1 second 10 seconds see note above AVR 20 BAL RK 240VAC 10A 100A 80A 30A 10A 2 x 120VAC balanced Circuit Breaker AVR 20 BAL CS 57 63Hz Front Panel AVR 20 BAL CB AVR 20 RK 120VAC 60Hz 20A 400A 200A 100A 16A AVR 20 CS 57 63Hz Circuit Breaker AVR 20 CB Front Panel AVR 15 RK 16A 300A 150A 75A 12A AVR 15 CS Circuit Breaker AVR 15 CB Front Panel Mechanicz necificatior MO n American Mode Model Number Input Line Cord Suggested Output Weight Size mm Connector included Wall Connector Size inch Rear Panel Receptacle Rear Panel w xd x h AVR 20 BAL RK IEC 320 C20 N6 15 14AWG NEMA 6 15R Qty 5 10 outlets 45 7kg 483 x 565 x 159 Inlet C19 15A 250V 15A 250V Medical grade 100 5lbs 19 x 22 25 x 6 25 AVR 20 BAL CS duplex 20A 45 0kg 432 x 556 x 162 AVR 20 BAL CB 99lbs 17 x 22 x 6 4 AVR 20 RK IEC 320 C20 N5 20 12AWG NEMA 5 20R Qty 5 10 outlets 45 7kg 483 x 565 x 159 Inlet C19 20A 125V 20A 125V Medical grade 100 5lbs 19 x 22 25 x 6 25 AVR 20 CS d
11. alia 10V These voltage sags brownouts and surges can stress components and shorten equipment life In the worst case catastrophic events can destroy valuable equipment In such real world conditions Torus Power AVR can protect your equipment and improve the quality and enjoyment of your audio and video experience www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 3 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units Front Panel Display gt Front Panel The Front Panel display consists of a 2 line LCD and 1 push button Typical display See section on AVR software for further information on the IP Address Voltage Faults If a high or low voltage condition exists for 30 seconds or more a voltage fault is displayed and the fault output is turned on and the system shuts down unless over ridden by the user As the output power from the Torus Power AVR is shut down all the connected equipment is turned off The AVR power switch remains in the ON position although there is no power to the load The connected equipment should be switched off When the voltage has been restored to the normal operating range the following procedure can be followed e The Torus Power AVR can be switched OFF and then ON e Wait thirty seconds to verify the fault condition no longer exists e The connected equipment should be switched on individually If the fault condition still e
12. ance on all sides when positioning the AVR for proper ventilation and allow 6 behind the AVR for adequate wiring space Do not place heat generating devices directly below the AVR Connecting components and using the AVR Using the AVR is as simple as plugging in audio and video components to the outlets on the rear panel The order and position in which you connect your components will not affect the performance of the AVR or your components Connect the AVR to the wall outlet and switch it on Turn on the components individually While the AVR has built in software that can be accessed via the Ethernet connection there is no need for you to use this software The AVR system provides all the standard features performance and benefits out of the box by simply plugging it in as described in this section You can use the AVR software to monitor the voltage conditions via your computer and for such additional features as being able to turn your system on off remotely and change the duration of the displays backlight Torus AVR Description Torus Power AVR Automatic Voltage Regulation is a full feature state of the art power conditioner isolating and protecting your system Like all Torus Power products the AVR series provides true isolation using massive toroidal transformers and protects all connected equipment from the risk of severe power line surges using series mode surge suppression In addition Torus AVR provides stable voltage t
13. assword Torus Power Home Network Configuration 2 If you have multiple AVR devices assign different Email Subjects to them to tell apart the logs of different devices Email Configuration SMTP Server User Name Password Email Address Email Subject Copyright 2009 Plitron Inc Torus Power AVR Set Password Enter New Password E Re enter Password Copyright 2009 Plitron Inc Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units AVR Setup This screen allows the user to configure two AVR parameters 1 Shutdown on Low or High line voltage The factory default is YES to shut down in case of fault conditions Unselecting this button will override and the AVR will remain on even if voltage drops or rises beyond the acceptable range 2 LCD Display Always ON is the default setting If you don t want the display on all the time you can select a time from O to 255 seconds When you have made your selections press SAVE SETUP Email Fault Alert Notification In the unlikely event your AVR experiences an issue the AVR will shut down and send an email notification if this section is configured After entering the configuration parameters use the Send Test Email button to confirm your settings are correct Set Password If you wish to change the password use this screen In case your forget your new password you can restore the AVR to
14. he load It does not indicate the peak current loads 2 There is a 20 second delay built into the AVR system to prevent nuisance switching The AVR will take approximately 20 seconds to change relay taps to switch to the proper output voltage setting 3 North American models 15A 20A Torus AVR will keep the output constant within the range of 115Volts to 125Volts with an input voltage of 90V to 130V Between 85V to 90V and between 130V and 135V the regulation will be reduced 4 North American models 20A BAL Torus AVR will keep the output constant within the range of 115Volts to 125Volts with an input voltage of 170V to 270V Between 160V to 170V and between 260V and 270V the regulation will be reduced 5 International models 4A 8A and 16A Torus AVR will keep the output constant within the range of 240 10Volts with an input voltage of 170V to 270V Between 160V to 170V and between 260V and 270V the regulation will be reduced 6 A drop in the Input voltage is normal when increasing the load on the Torus AVR This is a result of the impedance of the power line and is a function of the distance from the electrical panel Switch On Delay Feature The Automatic Voltage Regulation AVR feature is designed to handle normal utility fluctuations to provide the connected equipment with an optimal voltage supply It is common when utility power is restored after a blackout that the voltage supply is unstable for a few seconds To furt
15. her protect connected equipment your AVR is equipped with a start up delay feature When the power switch is turned on or when the power switch is on and utility power is restored power will not be connected to the output receptacles until the delay time has passed www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 8 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units Automatic Voltage stabilizer Maintains stable Voltage Output as shown in table below regardless of input voltage swings Fault protection Web interface Toroidal Isolation Transformer Complete isolation of primary from secondary allows attenuation of noise from 2kHz to over 1MHz Low Impedance Surge Removal and Complete Protection Protects against surges and lightning strikes up to 6000V 3000A s Series mode technology does not contaminate ground Front panel display provides Instantaneous 12 volt triggers power High Power capability Low Mechanical noise TORUS Micro controlier based Toroidal No sacrificial MOVs Medical grade outlets Technical switching system No alr core Inductors to Clean ground Features a Reliable relays rated for 404 Transformer generate noise Technologies a Narrow Bandwidth NET a Low Noise LONO ae a Low Inrush IMIN a Low Stray Fields LoSTray 6000 Surge a Triple Ground Screen UST 4
16. o keep equipment running in the optimal range of 115VAC to 125VAC for any input voltage from 90V to 130VAC International units operate within nominal input voltage such as 220V 230V 240V Torus AVR keeps them operating within a range of 10V See table on Page 9 for more details Torus Power AVR series uses a micro processor to monitor and control the power provided to connected components The front panel display on the Torus Power AVR indicates input and output voltages and displays output current as well as displaying fault conditions The Torus Power AVR is pre programmed to power down the system when a high or low fault conditions occurs user can over ride There are multiple interfaces built into the Torus Power AVR 1 Ethernet interface with built in web server allows any computer to view voltage and current readings and turn the AVR unit on or off 2 RS 232 is provided for connection to media control systems 3 Two 12V triggers are provided Does your system need automatic voltage regulation Under ideal conditions when the supplied power line is stable and dependable you may not need voltage regulation In such an ideal situation your equipment can operate within the normal tolerance of the line voltage In reality the power supplied to most areas is less than ideal due to Outdated power grids In most areas the power regularly drops or rises above the acceptable range in North America 5V Europe Asia Austr
17. r malfunction Torus Power will remedy the problem by repair or replacement as we deem necessary to restore the product to full performance This warranty is considered void if the defect malfunction or Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units failure of the product or any component part was caused by damage not resulting from a defect or malfunction or abuse while in the possession of the customer Failure to fully comply with Torus Power operating instructions voids the warranty www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 16 Torus Power products are marketed worldwide through Plitron Manufacturing Inc For sales contact torussales plitron com Phone 416 667 9914 Toll free 1 800 754 8766 Fax 416 667 8928 Technical inquiries torustechnical litron com Phone 416 667 9914 REV 11 07 2012 www TorusPower com Torus Power 8 601 Magnetic Drive Toronto ON M3 3J2 Canada 416 667 9914 Specifications subject to change without notice Torus Power 2012
18. ropean Socket 5 outlets 20A 250V Interpower Socket AUS 5 outlets 10A 250V Interpower Socket AUS 3 outlets 10A 250V Interpower Socket AUS 1 2 cycle Audio Video Power Isolation Units Load Current Capability Input Current 1 second 10 seconds Rating 96A 32A 16A 46A 16A 8A 20A 10A 4A 96A 32A 16A 46A 16A 8A 20A 10A 4A 96A 32A 16A 46A 16A 8A 20A 10A 4A Weight Size mm w x d x h 56 kg 483 x 662 x 203 55 kg 432 x 633 x 206 35 kg 483 x 565 x 159 34 kg 432 x 556 x 162 20 kg 483 x 489 x 102 19 kg 432 x 480 x 105 56 kg 483 x 662 x 203 55 kg 432 x 633 x 206 35 kg 483 x 565 x 159 34 kg 432 x 556 x 162 20 kg 483 x 489 x 102 19 kg 432 x 480 x 105 56 kg 483 x 662 x 203 55 kg 432 x 633 x 206 35 kg 483 x 565 x 159 34 kg 432 x 556 x 162 20 kg 483 x 489 x 102 19 kg 432 x 480 x 105 Height includes rubber mounting feet Rack Mount RK Consumer C www TorusPower com 11 12 REV 11 07 2012 Page 14 Rear Panel L t of International M 16A 250V Ivory Continental European Socket 13A 250V UK Socket o 0 Eno El Continental Europe 16A Model Number United Kingdom 16A Model Number AVR 16 CE RK AVR 16 CE CS and AVR 16 CE CB AVR 16 UK RK AVR 16 UK CS and AVR 16 UK CB 20A 250V Interpower Socket AUS Ethernet RS232 12V Trigger 12V Fault Power Inlet IEC320 C20 Rubber Mounting Feet may be removed if rack Australian 16A Model Number mounting AVR 16 AUS RK AVR 16 AU
19. ss displayed on the LCD into the browser window Press ENTER and the software will open 2 Use a three way Hub which is connected to an existing network You then connect both PC and AVR tothesame Hub Open a browser window from the PC Type AVR or the I P address displayed on the LCD into the browser window Press ENTER and the software will open Username and Password The password is required to change the setup of the Torus unit Username is admin This is factory set and cannot be changed Password is avr This is the default password and can be changed In case you forget your password the AVR can be restored to the factory default password avr by pressing and holding the button on the front panel for at least 10 seconds www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 5 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units AVR Software Menu Selections AVR Menu Selections AVR Status Switch Power Setup Email Configuration Set Password Torus Power Home website Network configuration Below is a screen by screen description of software options Connect to avr The server avr at Protected requires a username and password Warning This server is requesting that your username and password be sent in an insecure manner basic authentication without a secure connection User name admin Password Remember my password Voltage In
20. t AVR 8 AUS RK AVR 8 AUS CS 8A Operating Range 220 or 230 or 5 outlets AVR 8 AUS CB 170 270VAC 240VAC Australian 10V Interpower Socket AVR 16 UK RK AVR 16 UK CS 16A Operating Range 220 or 230 or 6 outlets AVR 16 UK CB 170 270VAC 240VAC UK panel mount 10V socket AVR 16 CE RK AVR 16 CE CS 16A Operating Range 220 or 230 or 8 outlets 16A 250V AVR 16 CE CB 170 270VAC 240VAC Ivory Continental 10V European Socket AVR 16 AUS RK AVR 16 AUS CS 16A Operating Range 220 or 230 or 5 outlets AVR 16 AUS CB 170 270VAC 240VAC Australian 10V Interpower Socket Note For the Nominal Output Voltages of the International models please see table at the top of page 9 under Block Diagram AVR System www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 11 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units D z On ane AVOU e MO A AME an anc ALE nation vode 19 Pro Series Rack Mount RK 17 Consumer Series C Faceplate Faceplate available in Black B and Silver S LCD Display Illuminated ON OFF Switch Circuit Breaker Ci it P i ti I tC t Rati The front panel power switch is also a circuit breaker As a circuit Per UL CSA and National Electrical codes devices with breaker it prevents excessive current from entering the AVR line cords and plugs must not consume more than 80 of a branch circuit s rating When the power is on the Switch is illuminated When the bre
21. ucts 240VAC require dual 120V phases 2 pole 3 wire Wall outlets for 240VAC are rated at 250V and will likely require special installation Dedicated outlets or any household or facility wiring should be installed by a licenced electrician to local codes Pictured below are suggested receptacle types for installation NEMA 6 15R NEMA 5 20R NEMA 5 15R for Balanced for Single for Single 20A unit 20A unit 15A unit 20A Medical Outlet 20A Medical Outlet ih E f la 1 0 Ge oan E To Tie ich FE There Fad Trigger i Et fener Power Inlet Single 20A Model Number AVR 20 RK Balanced 20A Model Number AVR 20 BAL RK AVR 20 CS and AVR 20 CB Accessory AVR 20 BAL CS and AVR 20 BAL CB Ground Stud RS232 15A Medical Outlet mae Ethernet 12V Trigger 12V Fault Single 15A Model Number AVR 15 RK Rubber Mounting Feet AVR 15 CS and AVR 15 CB may be removed if rack mounting www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 13 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units z JE Model Number AVR 16 UK RK AVR 16 UK CB AVR 16 UK CS AVR 8 UK RK AVR 8 UK CB AVR 8 UK CS AVR 4 UK RK AVR 4 UK CB AVR 4 UK CS AVR 16 CE RK AVR 16 CE CB AVR 16 CE CS AVR 8 CE RK AVR 8 CE CB AVR 8 CE CS AVR 4 CE RK AVR 4 CE CB AVR 4 CE CS AVR 16 AUS RK AVR 16 AUS CB AVR 16 AUS CS AVR 8 AUS RK AVR 8 AUS CB AVR 8 AUS CS AVR 4 AUS RK AVR 4 AUS CB AVR 4 AUS CS iad i E
22. uplex 20A 45 0kg 432 x 556 x 162 AVR 20 CB 99lbs 17 x 22 x 6 4 AVR 15 RK IEC 320 C14 N5 15 14AWG NEMA 5 15R Qty 5 10 outlets 20 9kg 483 x 489 x 102 Inlet C13 15A 125V 15A 125V Medical grade 46lbs 19 x 19 25 x 4 AVR 15 CS duplex 15A 20 2kg 432 x 480 x 105 AVR 15 CB 44 5lbs 17 x 18 9 x 4 13 Height includes rubber mounting feet www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 12 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units ne Ore and We xeceptea E NO n AME an Mode Standard 15A 120V Standard 15A 240 208V Used on Model Number AVR 15 RK AVR 15 CS and AVR 15 CB Equipment end IEC C13 Plug 5 15P Straight Blade 2 pole 3 wire grounding 15A 125V Cord 3 x 14AWG Length 2 5 m Used on Model Numbers AVR 20 BAL RK AVR 20 BAL CS and AVR 20 BAL CB Equipment end IEC C19 Plug 6 15P Straight Blade 2 pole 3 wire grounding 15A 250V Cord 3 x 14AWG Length 2 5 m Standard 20A 120V Suggested Receptacles for Installation Used on Model Number AVR 20 RK AVR 20 CS and AVR 20 CB Equipment end IEC C19 Plug 5 20P Straight Blade 2 pole 3 wire grounding 20A 125V Cord 3 x 12AWG Length 2 5 m Torus AVRs are high power products The outlets they are plugged into should be sufficient to provide the current to operate them without tripping circuit breakers within your junction panel Dedicated circuits are recommended Balanced input prod
23. wer Isolation Units R nt RK Consumer C 11 12 North American Model Numbers Ss 19 Pro Series 17 Consumer Maximum Input Output Output Rack Mount RM Series CS Available Voltage Voltage Connector Output Current Nominal Nominal AVR 15 RK AVR 15 CS 15A 120VAC 120VAC 10 outlets AVR 15 CB Operating Range 5V Medical grade 85 135VAC 15A AVR 20 RK AVR 20 CS 20A 120VAC 120VAC 10 outlets AVR 20 CB Operating Range 5V Medical grade 85 135VAC 20A AVR 20 BAL RK AVR 20 BAL CS 20A 240VAC 120VAC 10 outlets AVR 20 BAL CB Operating Range 5V Medical grade 170 270VAC 20A International Model Numbers SS 19 Pro Series 17 Consumer Series Maximum Available Input Output Output Rack Mount RM CS Output Current Voltage Voltage Connector Nominal Nominal AVR 4 UK RK AVR 4 UK CS 4A Operating Range 220 or 230 or 3 outlets AVR 4 UK CB 170 270VAC 240VAC UK panel mount 10V socket AVR 4 CE RK AVR 4 CE CS 4A Operating Range 220 or 230 or 4 outlets 16A 250V AVR 4 CE CB 170 270VAC 240VAC Ivory Continental 10V European Socket AVR 4 AUS RK AVR 4 AUS CS 4A Operating Range 220 or 230 or 3 outlets AVR 4 AUS CB 170 270VAC 240VAC Australian 10V Interpower Socket AVR 8 UK RK AVR 8 UK CS 8A Operating Range 220 or 230 or 5 outlets AVR 8 UK CB 170 270VAC 240VAC UK panel mount 10V socket AVR 8 CE RK AVR 8 CE CS 8A Operating Range 220 or 230 or 5 outlets 16A 250V AVR 8 CE CB 170 270VAC 240VAC Ivory Continental 10V European Socke
24. xists the AVR will require approximately 15 seconds to monitor the incoming voltage and the system will shut down again The user can program the AVR software to allow the system to remain on in case of fault see AVR software section for details www TorusPower com Rack Mount RK Consumer C 11 12 REV 11 07 2012 Page 4 Owner s Manual AVR Power Conditioners Audio Video Power Isolation Units erate Ie a dea LJ K Feet T gitr LETAN Peret TADO Fault Trigger RS 232 Ethernet Figure 1 AVR Rear Panel connections Ethernet Allows access to the AVR and internal software See AVR Software section for more details RS232 Allows access to automation and external control See Home Automation Interface commands at end of manual 12V Trigger On Off The AVR can be turned on and off by a 12 volt trigger input Applying 12 volts turns on the AVR and removing the 12 volts turns it off 12V Fault Output The AVR provides a 12 volt fault output through a jack on the back panel The output goes to 12 volts when a relay or voltage fault is detected The maximum current that can be drawn from this output is 75 mA AVR Software AVR software is resident in the microprocessor on the internal control board There are two methods to access the software 1 Connect the AVR to the Ethernet port Open a browser window on a PC that is connected to the same network through another Ethernet port Enter AVR or the I P addre