Home

"user manual"

image

Contents

1. Lion Controls Crimson 3 0 Device after Crimson is installed This may have already been accomplished if your G07 was configured using the USB port Once the driver is installed connect the G07 to your PC with a USB cable and follow Mounting the SD instructions in the Crimson 3 user manual INSERTION REMOVAL OF THE SD CARD Insert the SD card into the slot provided with the card oriented as shown The card is inserted properly when the end of the card is flush with the Graphite case To remove the SD card push in slightly on the card G07 PORT PIN OUTS POWER USB USB HOST DEVICE W R lt a2 gt 8 O Q N 09 1 COMMON POWER CONNECTOR RS485 RS232 RS ETHERNET PORTA PGM PORTA PORTB ETHERNET NIC RS485 RS232 COMMS PORT COMMS PORT BATTERY amp TIME KEEPING WARNING EXPLOSION HAZARD THE AREA MUST BE KNOWN TO BE NON HAZARDOUS BEFORE SERVICING REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I O WIRING AND BATTERY WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON HAZARDOUS A battery is used to keep time when the unit is without power Typical accuracy at 25 C of the Graphite time keeping is less than one minute per month drift The battery of a Graphite unit does not affect the unit s memory all configurations and data is stored in non volatile memory Ch
2. the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire suitably rated for the temperatures of the environment to which it is being installed If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significant electrical noise A power supply with an NEC Class 2 or Limited Power Source LPS and SELV rating is to be used This type of power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults SELV is an acronym for safety extra low voltage Safety extra low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred I O MODULE INSTALLATION Modules must be installed beginning with slot 1 left most slot with no empty slots between the modules and the order must match the modules order in the Crimson database Torque screws to 6 0 pound force inch 96 ounce force inch REMOVE RUBBER MODULE PLUG WARNING Disconnect all power to the unit before installing or removing modules COMMUNICATING WITH THE GO7 CONFIGURING A G07 The G07 is configured u
3. 6 W 17 W HMI With Module s 37W 38 W Must use a Class 2 circuit according to National Electrical Code NEC NFPA 70 or Canadian Electrical Code CEC Part I C22 1 or a Limited Power Supply LPS according to IEC 60950 1 or Limited energy circuit according to IEC 61010 1 Power connection via removable three position terminal block ENVIRONMENTAL CONDITIONS Operating Temperature Range 20 to 60 C Storage Temperature Range 20 to 70 C Vibration to IEC 68 2 6 Operational 5 500 Hz 4 g Shock to IEC 68 2 27 Operational 40 g 10 g modules w relays Operating and Storage Humidity 0 to 85 max RH non condensing Altitude Up to 2000 meters CERTIFICATIONS AND COMPLIANCES CE Approved EN 61326 1 Immunity to Industrial Locations Emission CISPR 11 Class A IEC EN 61010 1 RoHS Compliant UL Listed File E302106 Type 4X Indoor IP66 Enclosure rating Face only for all models Type 4X Outdoor Enclosure rating Face only for G07Sxxxx models CONNECTIONS High compression cage clamp terminal block Wire Strip Length 0 3 7 5 mm Wire Gauge Capacity One 14 AWG 2 55 mm solid two 18 AWG 1 02 mm or four 20 AWG 0 61 mm CONSTRUCTION Cast aluminum enclosure with NEMA 4X IP66 rating for indoor outdoor use when correctly fitted with the gasket provided Installation Category I Pollution Degree 2 WEIGHT 2 26 lb 1 03 Kg MOUNTING CLIPS INSTALLED OPERATOR INTERFACE INSTALLATION MOUNTING INSTR
4. UCTIONS FOOT MAY BE REMOVED FOR THICKER PANEL INSTALLATIONS r4 This operator interface is primarily designed for through panel mounting Four VESA mount tapped screw holes M4 x 0 7 5 mm deep are present on the rear of the panels to allow for stand or wall mounting Care should be taken to remove any loose material from the mounting cut out to prevent that material from falling into the operator interface during installation A gasket is provided to enable sealing to NEMA 4X IP66 specification Install the nine mounting clips provided and tighten to 6 0 pound force inch 96 ounce force inch evenly for uniform gasket compression METHODS AS SPECIFIED IN ARTICLE 501 4 ALL NONINCENDIVE CIRCUITS MUST BE h WIRED USING DIVISION 2 WIRING b 502 4 b AND 503 3 b OF THE NATIONAL ELECTRICAL CODE NFPA 70 FOR INSTALLATION WITHIN THE UNITED STATES OR AS SPECIFIED IN SECTION 19 152 OF CANADIAN ELECTRICAL CODE FOR INSTALLATION IN CANADA PANEL CUT OUT 7 060 179 3 r 4 869 123 7 4X R 10 2 5 MAX All tolerances 059 1 5 mm VESA MOUNT MIS D 75 DIMENSIONS 1 48 37 5 CONNECTING TO EARTH GROUND The protective conductor terminal is bonded to conductive UN parts of the equipment for safety purposes and must be connected to an external protective earthing system The third pin of the power connector of the G07 is chassis ground for the unit Your unit should be connect
5. anging the Battery To change the battery of a Graphite first remove power to the unit Remove the battery cover Grasp the top edge of the battery and push to the left to remove the battery from the holder Lift the battery out and replace with a new battery Replace the battery cover and re apply power Using Crimson or the unit s keypad enter the correct time and date Please note that the old battery must be disposed of in a manner that complies with your local waste regulations The battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents could come into contact with human skin The battery used by the panel is a lithium type BR2032 LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the products have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based
6. ed to earth ground protective earth The chassis ground is not connected to signal common of the unit Maintaining isolation between earth ground and signal common is not required to operate your unit But other equipment connected to this unit may require isolation between signal common and earth ground To maintain isolation between signal common and earth ground care must be taken when connections are made to the unit For example a power supply with isolation between its signal common and earth ground must be used Also plugging in a USB cable may connect signal common and earth ground USB s shield may be connected to earth ground at the host USB s shield in turn may also be connected to signal common POWER SUPPLY REQUIREMENTS The Graphite panel requires a 24 VDC power supply Your unit may draw considerably less than the maximum rated power depending upon the features being used As additional features are used your unit will draw increasing amounts of power Items that could cause increases in current are modules additional on board communications SD card and other features programmed through Crimson In any case it is very important that the power supply is mounted correctly if the unit is to operate reliably Please take care to observe the following points The power supply must be mounted close to the unit with usually not more than 6 feet 1 8 m of cable between the supply and the operator interface Ideally
7. red lit n Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net GRAPHITE SERIES 7 Color Touchscreen Operator Interface Installation Guide c US LISTED IND CONT EQ 34AD See the Red Lion website at www redlion net or the enclosed USB thumbdrive for full user manual Crimson software and software manual SAFETY SUMMARY All safety related regulations local codes and instructions that appear in this literature or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use this unit to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the unit CAUTION Risk of electric shock CAUTION Risk of Danger Read complete instructions prior to installation and operation of the unit ORDERING INFORMATION DESCRIPTION G07C0000 G07S0000 7 color touch screen indoor use 24 VDC powered 7 color touch screen indoor outdoor use 24 VDC powered DIMENSIONS In inches mm 7 70 195 5 2 00 50 8 a 2 97 76 Drawing No LP0907B Released 04 14 SPECIFICATIONS POWER 24 VDC 20 G07C G07S Typical Power HMI only 9W 10 W Maximum Power HMI only 1
8. sing Crimson software Crimson is available as a free download from Red Lion s website Updates to Crimson for new features and drivers are posted on the website as they become available By configuring the G07 using the latest version of Crimson you are assured that your unit has the most up to date feature set Crimson software can configure the G07 through the RS232 PGM port USB port or SD card The USB port is connected using a standard USB cable with a Type B connector The driver needed to use the USB port will be installed with Crimson The RS232 PGM port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer If you choose to make your own cable use the G07 Port Pin Out Diagram for wiring information The SD card can be used to program a G07 by placing a configuration file and firmware on the SD card The card is then inserted into the target G07 and powered Refer to the Crimson literature for more information on the proper names and locations of the files USB DATA TRANSFERS FROM THE SD CARD WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION In order to transfer data from the SD card via the USB port a driver must be installed on your computer This driver is installed with Crimson and is located in the folder C Program Files Red
9. upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations 20 Willow Springs Circle York PA 17406 USA 1 717 767 6511 info redlion net www redlion net 4

Download Pdf Manuals

image

Related Search

Related Contents

  Manual de usuario  ダウンロード  Lenco Autoradio + CD + MP3 CS-176 USB  (franᅵais) 0.29 MB (AM_20186_BA_Eurotops_FRA_01)  Apprentissage de la langue en maternelle A Popet  Recaro Young Expert  BEDIENUNGSANLEITUNG DVM-90 DVM-91 DVM-92  Panasonic AW-PB506AL Camera Accessories User Manual  Oregon Scientific RMR500ES  

Copyright © All rights reserved.
Failed to retrieve file