WEB-IO Control Unit USER MANUAL

image

Contents

1. FRX Set Fast Response status x 0 1 Off On Request the Remote Control Service Z Requests the Enable Status of Log Memorv MP Requests the logging memorv parameters memorv size current location overwrite status M2 Reads the data memorv content MR Reset the data memorv content IPSES S r l EG Lazzarotto 10 20020 Cesate MI ITALY IPS ES el 39 02 39449519 Fax 39 02 700403170 http jew ipses com e mail info ipses com 49 1 5 j N O WEB IO USER MANUAL AJ P 3 E 3 scientific electronic taw o d l Enables telnet service password Command help Note the commands related to Log memory are implemented only in firmware version supporting the RTCLOG module The change of the password in telnet does not perform a reboot of the board or the automatic disconnection from the current session on the contrary to what happens in the analogous http service Obviously next telnet access to board here included the use of demo software must be authorized by the new password The typing of an excessive number of chars over 29 saturates the receiving buffer of the card and consequently the session will be lost The following table lists of answers related to the edited command type The answer is preceded by a 18 chars length descriptive string For example the SN command generates the following answer Serial number 2010000 The data answer is preceded by a descriptive string w
2. l n dep v Pagina Sicurezza y Strumentiv o WEB IO Control Panel Startup Configuration Timeout Configuration PLC Configuration SNMP Community Configuration I O Label Bootloader Setting To enable the bootlader mode for WEB IO board 2011000 enter the valid http password i and click the Run Bootloader Mode button i The card will remain in bootloader mode until you don t load a new application or you i don t leave the bootloader state http Password Run Bootloader Mode Configuration E mail Configuration Remote Control Configuration TCP IP Configuration Securitv Settings Resume Bootloader Mode Info Copyright 2009 11 IPSES S r l www ipses com Internet Modalit protetta attivata fg y A10 Picture 16 Bootloader mode access page The Bootloader Setting page shown in Picture 16 allows to run the bootloader mode on the board for a firmware upgrade To enable this mode it is mandatory to insert the correct http password before clicking on the Run Bootloader Mode button so you will be redirect to the following network address http current ip bootloader where current IP is the current IP address of the board i e 192 168 0 16 Picture 17 shows the only page reachable in Bootloader mode Until the board remain in this status the SNMP server and the telnet server are unreachable while all the outputs and PLC and Timeout function are disabled Warning the boa
3. 6 WEB O Application Control provided by SESS m DI tp y Pagina Sicureza v Strumentiv y 7 WEB IO Control Panel Startup Configuration Startup Configuration Serial number 2011000 Timeout Firmware version v01 05 0000 Configuration Ek tie Startup Status Panel SNMP Communitv AFTER Saved Status I O Label i Configuration i 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 E mail Digital Output CO 3 2 Cc J Configuration Remote Control eR Configuration j TCP IP 01 2 3 4 5 6 7 8 9 10 11 12 13 14 15 p Configuration i Digital Output 6 e ee ee Security Settings Resume Save Startup Setting Bootloader Mode Info Copyright 2009 11 IPSES S r l www ipses com Fine Internet Modalit protetta attivata fa y Q10 y Picture 7 Startup configuration page Startup Configuration page shown above in Picture 7 allows to read board parameters like Serial Number and Firmware Version and to set the startup output status through the Startup Status Panel form Saved Status section displays the actual startup configuration stored in memory yellow LEDs indicate outputs of which configuration is already saved Clicking on LEDs of Set Status section it is possible to set the new startup configuration which will be stored only after the pressure of Save Startup Settings button If the freezing function for http page commands is enabled the
4. PSES scientific electronics WEB IO Control Unit USER MANUAL Rel 01 06 0000 Hardware code WEB IO EXE LE E EE AE A MA ARI Jf l i lli fq lD2 2 fi MIL ik LE GJEL 1 2 EEE zi on es Bh MERES Y B TA CONCEIVING PLANNING DEVELOPMENT IN SCIENTIFIC ELECTRONICS WEB IO USER MANUAL AJ P S cientilic electronics Information provided in this manual is property of IPSES S r l and must be considered and treated as confidential This publication can only be reproduced transmitted transcribed or translated into any human or computer language with the written consent of IPSES S r l Information in this documentation has been carefully checked and is believed to be accurate as of the date of publication however no responsibility is assumed of inaccuracies IPSES will not be liable for any consequential or incidental damages arising from reliance on the accuracy of this documentation Information contained in this manual is subject to change without notice and does not represent a commitment on the part of IPSES The design of this instrument is subject to continue development and improvement Consequently the equipment associated to this document may incorporate minor changes in detail from the information hereafter provided All brand or product names are trademarks or registered trademarks of their respective holders This manual in English is the original version Printed in Italy
5. gt J Effettua la ricerca 7 de e H Condividi E Ap Controllo 7 Ey Traduci I Compilazione autom gt gir Preferiti 3 Siti suggeriti f Raccolta Web Slice v WEB IO Application Control provided by IPSES S fat 9 3j deh v Pagina Sicureza y Strumenti v YY LN IN ime WEB IO Control Panel A Index PLC Configuration Startup Confi ti onfiguration Serial number 2011000 Timeout Firmware version v01 05 0000 Configuration A net PLC Configuration Panel SNMP Community Configuration Select Output Out 3 x I O Label Configuration E mail l Logic AND q Configuration i 012 345 6 7 B 9 1011 12 13 14 15 Remote Control Input Filter 249 323 2 E C Configuration m TCP IP Configuration Security Settings Seb Stat Logic AND v Input Mask Resume Bootloader Mode Uu Input Filter eee e ee Input Mask de BB uu 0 12 33 45 6 7 8 9 101112131415 This button allows to disable all Programmable Logic Mask without modifing Filter s configuration settings already saved Disable All PLC Mask Copyright 2009 11 IPSES S r l www ipses com Internet Modalit protetta attivata fav QAS y Picture 9 Programmable Logic Configuration PLC page PLC Configuration page shown in Picture 9 allows to manage each output based on the customizable status of the inputs from 0 to 15 and
6. 0 Output 12 1 Output 13 0 Output 14 0 Output 15 1 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY pa 5 PS ES Tel 39 02 39449519 Fax 39 02 700403170 S r ES http www ipses com e mail info ipses com ij y i eraic echoed 49 cientilic electronics 2 Te P LOS es T WEB IO Application Control provided by IPSES S r l Windows Internet Explorer fornito da IPSES Sr Sen G http 192 168 0 16 remote index htm x Google J Effettua la ricerca 7 b emm Condividi B Ap Controllo 3 Traduci Sf Compilazione autom gt Ae 7 J Entra gt iy Preferiti q Siti suggeriti y g Raccolta Web Slice v WEB IO Application Control provided by IPSES S I fat C3 deh v Pagina Sicurezza y Strumentiv WEB IO Control Panel Index Remote Control Configuration Startup e o nfi g ura ti on TET E ET A ye pa re Board MAC Address 00 50 C2 C9 50 70 Timeout Board IP Address 192 168 0 16 Configuration i PLC Configuration SNMP Communitv Configuration MAC Address 00 50 C2 C9 50 71 I O Label IP Address 192 168 0 17 Configuration i Local UDP Port 2610 E mail Remote UDP Port 2611 Configuration i l Enable Remote Control Communication Remote Control Configuration i i Save Configuration TCP IP i Configuration i Security Settings j Remote Control communication status Resume i Bootloa
7. the status is shown directly on the board An integrated temperature sensor allows to know in real time the temperature of the system CAN IO is placed in IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax 39 02 700403170 gt iCare elechonici B pet ipses com e mail info ipses com 2D 1 5 j N WEB IO USER iio S P S ES scientific electronics WEB IO Input output Card with 16 inputs and 16 outputs Ethernet interface integrated web telnet and SNMP servers and SMTP client WEB IO is a card to manage sixteen optocoupled inputs and sixteen optocoupled outputs with Ethernet interface equipped with a web a telnet and an SNMP servers and an SMTP client The web server allows to connect and to manage the card using any web browser i e Internet Explorer or Firefox with no needs to install a software on your PC Besides the card can be connected directly to a switch or to a router with no need to use a PC It is also possible to develop a customized software managed by telnet service or SNMP client The SMTP client allows to send alert email based on inputs status change events WEB IO can be directly connected to PLC to input devices from operator and to other I O systems Each input and output status can be read by a web browser or a telnet client at any moment besides it is shown directly on the board thanks to LEDs fixed on On request the card can be equipped with a
8. External module disabled string 37 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY V Tel 39 02 39449519 Fax 39 02 700403170 LL FO ES http www ipses com e mail info ipses com 090 1 5 j N L WEB IO USERMANUAL Y4 PIES aF E oo l pn q pa qa ES a E j r s uL S i h mm B f f e al B d telnet SERVER To connect to telnet server implemented on the board it is enough a telnet client program i e the client installed in your operative system or the hyperterminal The configuration parameters of the client must be telnet communication port 23 echo on if you want to see typed characters termination characters CR LF gt Inn Picture 20 shows the initial snapshot to access the server insert the telnet password then press Enter m Em Telnet 192 163 0 16 To access the service insert the passuord Password ipses Press q to quit 2 7 IHAL Commands list Serial Number Firmware Version Build Date Stack Version Board Hostname Board MAC Address Board IP Address Board Subnet Mask Board Gateway Address Board Primary DMS Address Board Secondary DNS Address Head WiFi SSID Read WiFi Authentication Read WiFi Key Read Input status x H 15 A single all inputts gt gt Head Output status x 8 15 A single all outputs gt gt Re i ee a T Set Active Output x H 15 A single all outputts gt gt B
9. Log Memory button allows to read the memory content shown in the Log Report it is possible to export the content of this field in a text file txt with the Export Clipboard to file button The Erase Log Memory button erases all the memory content 51 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 439 02 39449519 Fax 439 02 700403170 Ss http www ipses com e mail info ipses com 19 1 5 j N scientific electronics M IS p Os wessousermawa LO IPSES mia na Pane Ye Log rane Thu 19 Mov 2009 12 05 45 inkaFAF out xF C2 Thu 15 Mov 2009 12 05 48 in 0x3FAD out FICA Thu 19 Mov 2009 12 05 50 in ikEFAD out FICA Thu 19 Mov 2009 12 05 51 in IxAFAD out xFOC2 Thu 19 Nov 2009 12 05 53 imikEFAD out xFOC2 Thu 19 Mov 2008 12 05 53 in ikB7AD out FICA Thu 19 Mov 2009 12 05 55 in ikEFAL out xF CZ Thu 19 Mov 2009 12 05 55 in xB 7 AD out dxF C2 Thu 15 Mov 2003 12 05 55 in QxBFAD out FOCA Thu 19 Mov 2009 12 05 55 in 0xB7AD out xFOC2 Thu 19 Mov 2009 12 05 57 imikb7AF out xF C2 Thu 19 Mov 2009 12 06 03 in IxB54F out BICA Thu 19 Nov 2009 12 06 08 in lkB7AF out xFU C2 Thu 19 Mov 2009 12 06 11 in xBFAF out FICA Thu 19 Mov 2008 12 06 13 inikAFAF out ikFOCZ Picture 29 Log Panel window 52 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax 39 02 700403170 l http www ipses com e mail info ipses com 19 i
10. PUPR OR INE ORNA OI cm ET 64 PROBLE REF OR E 64 ENGINEERING PROBLEM REPOR pori 65 M nM scientific echoed http www ipses com e mail info ipses com 210 1 EI j N Bop PO mamma REVISION HISTORY 0 1 Manual revision history mm uem emo Date July 2009 01 01 0000 Added description of the jumper in Card Rivolta A September 2009 description paragraph added description of Mancuso C software configuration in Addresses configuration WEE modified the descriptions and pictures n http server telnet server and Demo software rad due to firmware and software upgrade Updated the command list in telnet server paragraph Added the maximum board thickness in Technical features paragraph Added TPC IP Address configuration software description 01 02 0000 Added description of connectors in Card Rivolta A April 2010 description paragraph Added description of RTCLOG module updated command list for telnet server and modified the description and pictures in http server telnet server and Demo software paragraphs Added description of Bootloader function in http server paragraph and modified the Functioning Modes paragraph Added description and pictures for the management of the SNMP server in the SNMP server paragraph 01 02 0001 vr pga si tua dti d command list for telnet server due to a ud July 2010 firmware upgrade and modified descripti
11. SUPPORT INFORMATION The customer is at liberty to contact the relevant engineer at IPSES S r l directly Telephone 39 02 39449519 39 02 320629547 Fax 39 02 700403170 Email support ipses com PROBLEM REPORT The next page is a standard template used for reporting system problems It can be copied and send as a fax Alternative bugs may be reported by emails in this case please insure that the mail contains similar information listed in the Engineering Problem Report form IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY pran PS ES Tel 439 02 39449519 Fax 439 02 700403170 LAT B pet ipses com e mail info ipses com 210 1 EI j N scientific electronics I l e ls Os gt IPSES ENGINEERING PROBLEM REPORT Problem describer Name IPSES s r l Via Suor Lazzarotto 10 Companv Cesate MI Italy Fax 439 02 700403170 Product Name Version Serial No Report Type bug change request or technical problem Major bug Urgency Minor bug jii High Change request Medium Technical problem Low Problem Description Reproduction of Problem IPSES s r l Action notes 65 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY AAA PS ES Tel 39 02 39449519 Fax 39 02 700403170 Y http www ipses com e mail info ipses com scientfic electronics 49 1 5 j ESI Dv l de PIOS ess Product code WEB IO Rel 01 06 0000 IPSES S r l Vi
12. Tel 39 02 39449519 Fax 39 02 700403170 http www ipses com e mail info ipses com 49 1 5 j N Dl PS ES i ierific Hechorics KJDIPSES scientific electronics e f P LOS To raise the security to Level 1 it is necessary to set the Freeze http page commands checkbox the control buttons on the http pages will be disabled but the URL commands will continue to be processed by the board as described below in the I D MANAGEMENT THROUGH http paragraph To set Level 2 is enough enabling the Freeze URL line commands checkbox the Freeze http page commands checkbox will be automatically enabled and both buttons on http pages and URL commands will be blocked However the reading I O URL commands will keep to be processed Resetting board parameters will configure again the security Level to 0 The current security settings are shown during the page loading To save new settings it is mandatory insert the correct http password before clicking the Save Security Settings button WEB IO Application Control provided by IPSES S r l Windows Internet Explorer fornito da IPSES S r l np x GU http 192 168 0 16 bootset boot htm v p x Google J Effettua la ricerca 7 b em B Condividi B Ap Controllo 3 Traduci S Compilazione autom gt Ap Ly Entra gt gir Preferiti 3 Siti suggeriti v g Raccolta Web Slice v WEB IO Application Control provided by IPSES S
13. can be done only with the http service while the telnet service allows only to cancel the saved records The reading of the memory contents can be done with http service as explained in the next paragraph LOG RECORDS VISUALIZATION THROUGH http both with telnet service The Log memory if enabled is written at every inputs statuses change The data stored are RTC date inputs statuses and outputs statuses The memory can store up to 4093 samples The memory filling can be managed in two ways A cyclic filling Overwrite mode where the writing cycle restart to write from the initial location after the last location is reached in this mode the newer datum overwrites the older one and the user must assure itself to reading the data before they will be overwritten The other mode Stop to end mode assures that the data will be written until the memory reaches its last location while the next data will be lost If the communication is lost the current page shows the following error message Connection to WEB IO board was lost LOG RECORDS VISUALIZATION THROUGH http The Log records can be read also through http protocol To facilitate the development of your applications it has been implemented the possibility to read the entire memory contents or only the last saved records by edit the following URLs http current ip log cgi and http current ip log cgi n x where current ip is the board address i e 192 168 0 16 and x is the number o
14. eb22201 1413 Octetstring E Via Trieste 48 I company D address 0 zp _code 0 phone 0 OctetString OctetString OctetString OctetString OctetString OctetString OctetString OctetString teg teg Address web_site 0 apReceiverNumber 0 i i El i jo OOOO trapEnabled 0 Me irapEnabled 1 nmn trapReceiverIPAddress 0 trapReceiverIPAddress 1 trapCommunity 0 i l ma lm oA AA C5 ES C a C C E m 192 168 0 52 0 0 0 0 p Octe ki o fA tring MM EX M j HE di t E Een RM i i i m ES i sis 51518 EIE IT I Ed 8 99 8929999939 i STS sss sisi sis 22844 mimimimim l 5151 515 5 i184 m m 5 8 8315 RE 5 o o e e 515 aa ss g aa iReasoning MIB Browser Picture 21 MIB browser displav 2 Downloadable from www ireasoning com web site 42 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax 39 02 700403170 http www ipses com e mail info ipses com 19 il 5 j N acera electronics cientilic electronics Pe f 1 5 b Oso gt IPSES Options ss Leite mic Port Read Community esee Write Community SNMP Version Picture 22 MIB browser and SNMP Agent configuration Picture 22 shows the MIB browser and the configuration of the related SNMP Age
15. freezing function for http page commands is enabled both the buttons are disabled The Timeout function previously described and shown in Picture 8 has priority over PLC function if timeout occurs all PLC enabled functions are temporarily disabled until the board will receive a new command or request 24 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax 39 02 700403170 Bs http www ipses com e mail info ipses com IM 1 5 j N cientilic electronics Que iu i Q5 lt ESIPSES WEB IO Application Control IPSES S r l fornito da IPSES S r l QU v http 192 168 0 16 sn mp snmpconfig htm X Google J Effettua la ricerca 7 gt H Condividi E amp Ay Controllo 7 E Traduci f Compilazione autom gt B Ae oL Entra vy Preferiti 383 amp j 5itisuggeriti f Raccolta Web Slice v l e WEB IO ja vu provided by IPSES S fi Y ye kal v Pagina Sicurezza v Strumenti v B WEB IO Control Panel SNMP Community Configuration Startup Configuration B Serial number 2010000 Timeout Firmware version v01 05 0000 Configuration PLC Configuration Configure multiple community names if you want the SNMPv2c Agent to respond to the NMS SNMP manager with different read and write community names If less than three SNMP Community communities are needed leave extra fields blank to disable them Configur
16. http 192 168 0 16 go to the TCP IP Configuration page then set the new parameters and save them Verify Save Reboot operation works successfully install the card in the network and access it with new parameters Software configuration procedure With the board already powered on insert the jumper J1 Run the address configurator software WEB IO Address Configurator exe included in the installer CD provided with the board and follow the steps described in the paragraph TCP IP ADDRESS CONFIGURATION SOFTWARE atthe end of the configuration remove jumper J1 IMPORTANT do not disconnect the power supply during the address configuration procedure a supply reset restore factory parameters IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 QC nERC thec horita B pet ipses com e mail info ipses com 1O 1 5 j N scientific electronics B P LOS es REMOTE CONTROL SERVICE The Remote Control service based on P2P paradigm allows the bidirectional communication and the reciprocal control between two WEB IO family cards wherever they are The transportation protocol is UDP This service is especially useful if you need to acquire and process signals in locations distant from each other Board A Board B LAN Internet Network The previous picture shows the communication flux when the service is active on both cards the inpu
17. inputs and 16 outputs and USB or RS232 interface 2Moo5202225295252 9552 5 22 el Sa d ug 859529590258059558 252254 101616 is a self powered card to manage sixteen optoisolated inputs and sixteen optoisolated outputs with USB interface The model is available also with RS232 interface in this case the card needs external power supply 101616 can be directly connected to PLC to input devices from operator and to other I O systems the status of each input On request an integrated temperature sensor allows to know in real time the temperature of the system 101616 is placed in CAN I O Input output Card with 16 inputs and 16 outputs with CAN USB and RS232 interface AAA SN A am nent O DL SP a ae a sr PET ETT A TE ON reve et he te et eee Pu ji riga REE CAN IO is a control unit equipped with CAN USB and RS232 interfaces to manage sixteen optocoupled inputs and outputs The card can work as standalone device on CAN BUS Its configuration is achieved either through USB in this case the board is self powered or through RS232 interface Easy to use and to configure thanks to the provided software CAN IO is the right answer to the need to acquire and to drive digital signals through already existing CAN bus CAN IO can be directly connected to PLC to input devices by operator and to other I O systems Each input and output status can be read by a field bus at any moment Besides thanks to LEDs fixed on
18. is recommend to handle the board with care the area around the switching regulator works at high temperature and it is possible to burn oneself IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 439 02 39449519 Fax 39 02 700403170 L T ni ipses com e mail info ipses com 49 i 5 j N o gt li b f O WEB IO USER MANUAL gt IP SES ETHERNET MODULE The physical layer of the Ethernet network protocol supports the 10Base T standard and it is fully compliant with the 10 100 1000Base T standard WEB IO can be connected to any commercial router or switch without problems The physical connection between the card and the network cable is made by the RJ45 connector as shown in the following picture Link LED Activity LED The green LED Link LED indicates the detection of the Ethernet network the yellow LED Activity LED is on during the communication packets Tx Rx activity IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 lt I gt B pet ipses com e mail info ipses com 1O 1 5 j N i eraic echoed scloniific electronics pr li 916 ls Oso i gt IPSES NETWORK SERVICES WEB IO board hosts a server for http service a server for telnet service a server for SNMP Simple Network Management Protocol service and a client for SMTP Simple Mail Transfer Protocol service Data transfer is based on a TC
19. making the development quick and easy Each library is provided with a help file which explains deeper each function included with 62 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 Fax 39 02 700403170 http www ipses com e mail info ipses com CL GI gt IPSES core eechonmct iu b QS LL es CONTACTS IPSES S r l conceives projects and markets electronic and scientific instruments The customized planning of our devices allows us to answer specific necessities for customers asking for embedded systems IPSES clients enjoy access to a dedicated project engineering team available as needed Our pool consists of highly competent professionals whose experience in this field is extremely strong Thanks to constant updating and technical development IPSES is a leading company combining the dynamism of a young group into the competence and reliability of a qualified staff ME Xm ds RR uiae LLL Research and development office p Via Suor Lazzarotto 10 a P s E s 20020 Cesate MI O E Italy s j tel 39 02 39449519 39 02 320629547 fax 39 02 700403170 e mail info ipses com http www ipses com IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY AM PS ES Tel 39 02 39449519 Fax 39 02 700403170 P 4 A B pet ipses com e mail info ipses com 1O 1 5 j N icerige tis cir rw i O weesousermawa CZ IPSES cientilic electronics P
20. packets are detected the LED is green The ping function is useful to test the reachability of the destination board 29 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax 39 02 700403170 Ue http www ipses com e mail info ipses com l 49 1 5 j a scientific electronics 2 Te P LOS es Till the Remote Control service is enabled the PLC and the Timeout functions are disabled and the manual control of the outputs is forbidden The firmware that manages the RTCLOG module allows to save the inputs status and the outputs status of the board in the Log memory if the Remote Control service is enabled and the communication with the board B is detected the outputs status on board A correspond to the inputs status of the board B By this way it is possible to log up to 32 inputs status with only one RTCLOG module amp WEB IO Application Control provided b i O m GA je http 192 168 0 16 protect config htm Y Ena 3 al Py x Google 29 Effettua la ricerca gt m d 8 Condividi Eh Ap Controllo 7 3 Traduci B Compilazione autom f 7 8 his M vy Preferiti 383 E Siti suggeriti f Raccolta Web Slice v amp WEB IO Application Control provided by IPSES S Jm o E ode y Pagina Sicurezza y Strumentiv 9 WEB IO Control Panel TCP IP Configuration Startup Configuration Timeout Configurat
21. r l Windows Internet Explorer fornito da IPSES S r l EHE x QU Use http 192168 016 info htm l alex IID eoe p Google 29 Effettua la ricerca gt Gu Condividi E amp Ag Controllo 3 Traduci Sf Compilazione autom Ae 7 y Entra gt vy Preferiti 3 3 E Siti suggeriti f Raccolta Web Slice v e WEB IO Application Ga provided by IPSES m a E 1 de y Pagina Sicurezza y Strumenti v WEB IO Control Panel Board Info WEB IO Board Application Control Startup Configuration Timeout Configuration Serial number 2011000 Firmware version v01 05 0000 PLC Configuration Build date Mar 30 2011 13 26 20 SNMP Community Stack version v5 25 Configuration Bootloader version NaN I O Label Web Pages version v1 50 po io MAC address 00 50 C2 C9 50 70 E mail Configuration Designed and developed by IPSES S r l Cesate MI Remote Control Configuration TCP IP Configuration Security Settings Resume Bootloader Mode Info Copyright 2009 11 IPSES S r l www ipses com Internet Modalit protetta attivata fg y 100 Picture 18 Firmware version information page 33 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY m PS ES Tel 39 02 39449519 Fax 39 02 700403170 gt http www ipses com e mail info ipses com 49 1 5 j N acera electronics scientific electronics li Te P LOS es The Board Info page shown in Pict
22. 0 20020 Cesate MI ITALY A 1 5 nct ice nERC elechon cientilic electronics Pe f l b IOS L lt E5IPSES Supported protocols Telnet the card can work as a telnet server HTTP the card can work as a web server SNMP the card can work as an SNMP server SMTP the card can work as an SMTP client SNTP the card can work as an SNTP client able to request network date and time with RTCLOG module l 58 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY E Tel 39 02 39449519 Fax 39 02 700403170 Q gt P S ES i ipriifi elec iONW A http www ipses com e mail info ipses com 090 1 5 j N li BIOS eus scientie electronics IPSES I O CARD AVAILABLE MODELS IO 69 Input output Card with 6 inputs and 9 relay outputs and USB interface IO 69 USB is a self powered card to manage six optocoupled inputs and nine relay outputs with USB interface A timeout control allows to protect the connecting devices turning off all the outputs if it does not receive commands from the host within a time configurable through software Furthermore there is the possibility to program all the outputs so that each one will activate only when inputs reach assigned conditions in this case IO 69 acts like a programmable logic controller PLC The card is produced in two versions with single pole double throw relay SPDT and with single pole single throw relay SPST IO 1616 Input output Card with 16
23. 39 02 700403170 A http www ipses com e mail info ipses com 2D 1 5 j a core elechonici U Ej PIT Mail generated by 2010000 board on inputs event KJDIPSES scientific electronics Sending e mail is an asynchronous process subjected to the successfully connection established with the mail server If you cannot receive the mail as expected be sure the SMTP server pact 4 and addresses parameters are correct The Enable Sending Input 2 0 inputs Mail checkbox should be selected m Input4 1 The board does not point out an advise if the mail sending Input5 0 fails Input amp 1 The time necessary to generate and process each mail Input7 1 depends on the SMTP server communication The minimum m waiting time between two consecutive mail is 1 second sie a x A new mail can be generated only when the process related to input d previous mail is ended Inputi2 1 When a mail process is active any input status change is Input13 0 ignored this means that during this phase any input changes Input 14 0 which may occur in subsequent time instants are neglected Input 15 1 The board will register only the first useful change occurred after the end of current mail elaboration process Suri The picture on the left shows an example of generated mail Output 2 1 body Output 3 0 Output4 0 Outputs 1 Output 6 0 Output 7 1 Qutput 8 Q Output 9 0 Output 10 0 Output 11
24. 39449519 Fax 39 02 700403170 L L iC nEREC Hech B pet ipses com e mail info ipses com 1O 1 5 j N PE SNMP SERVER scientific P OS sts electronics To connect the SNMP server implemented on the board user can use any MIB browser program like Reasoning MIB Browser Once the communication with the board is on it is necessary to be sure the browser is correctly configured according the following check list The MIB Tree must include the mib file provided with the CD To load it use the command File gt Load MIBs and search through the folders selecting the file WEB IO mib The Agent must be configured properly with communities parameters To verify it use the command Tools gt Options and select the tab Agents The Add button allows to configure a new Agent setting IP board address Port 161 Version 2 Read and Write Communities ib iReasoning MIB Browser File Edit Operations Tools Bookmarks Help Address 192 168 0 16 eJ ipses iso org dod internet private enterprises ipses EH dy product gc setup i E ES taps ES trapEntry D trapReceiverNumber Ef trapEnabled i status event iso org dod internet private enterprises ipses outputs v IS Vae mee mame0 WEB IOSIN 2010001 OctetString Advanced OID 136 141 17095 4 Operations Get Subtree co E veson VoL0200R X aeo OO O Oo
25. 439 02 700403170 http www ipses com e mail info ipses com cientilic electronics l IQ ls O G gt IPSES Commands list is displayed below Q Closes telnet connection Ao o Requests board serial number FV Requesis firmware version H BD Requests firmware build date O o 1 SV Requests TCP IP stack version 0 1 ooo MAC S Requests board MAC address 0 0 0 0 1 PP RequestsboardIPaddress S 1 GW JjRequesisboardGatewayaddress 1 ss E B SP S XXXXXXXXXXXXXXXX or SPD Sets startup status x 0 1 Off On of each output from Outo to ES SIXXXXXXXXXxxxxxxx Out15 Requests timeout settings outputs status Out0 Out15 timeout mE time 0 8 TM S Sets timeout status x 0 1 Off On of each output from Out0 S XXXXXXXXXXXXXXXX to Out15 3 Requests mask and filter settings MO M15 FO F15 related to PLCy In0 In15 inputs for the y output y 0 15 CI Sets the mask status x 0 1 Off On of each input from InO to Sets the filter status x 0 1 Off On of each input from InO to d In15 for the y output y 0 15 PLCy Lbd Sets the bread logic function x 0 1 AND OR for the y 3 output y 0 15 MT Requests the operating status of the notification of change of inputs EICx Enable Disable the notification function of change of inputs x 0 1 Off On UBA
26. Ap J Entra gt gir Preferiti 3 Siti suggeriti v g Raccolta Web Slice v WEB IO Application Control provided by IPSES S Fu El El od y Pagina w Sicurezza y Strumentiv iv WEB IO Control Panel Index Main Panel Startup Configuration Timeout E i Board status Configuration eee PLC Configuration SNMP Community Configuration l Input status e e e e 9000 e oe I O Label f E Configuration 2 Output status e amp e o o 6 SEE oe GUGOG G9 6 8 68 7 8 8 G9 89 G2 83 9 Gs Remote Control Configuration T Temperature C 34 5 TCP IP Configuration j Remote Control communication status Security Settings Resume Bootloader Mode Info Copyright 2009 11 IPSES S r l www ipses com Internet Modalit protetta attivata fa y R100 Picture 6 http server index page On the left side of the WEB IO control panel there is the menu surrounded in orange in Picture 6 which allows to access the pages implemented on the http server Board status surrounded in blue shows D2 D3 and D4 status LEDs mounted on the card 21 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY m PS ES Tel 39 02 39449519 Fax 39 02 700403170 A http www ipses com e mail info ipses com 49 1 5 j N acierta elec hordas scientific electronics 2 Te P LOS es Input status and Output Status fields surrounded in violet report respectively t
27. Copyright 2009 2015IPSES S r l All rights reserved 2 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY AM Tel 39 02 39449519 Fax 39 02 700403170 Y 21 PS ES http www ipses com e mail info ipses com IM 1 5 j a icerige tis cir rw i scientific electronics v l JI i O Ves COIPSES GUARANTEE IPSES warrants to the end user in accordance with the following provisions that its branded hardware products purchased by the end user from IPSES company or an authorized IPSES distributor will be free from defects in materials workmanship and design affecting normal use for a period of one year as of the original purchase date Products for which proper claims are made will at IPSES s option be repaired or replaced at IPSES s expense Exclusions This Guarantee does not apply to defects resulting from improper or inadequate installation use or maintenance actions or modifications by unauthorized third parties or the end user accidental or wilful damage or normal wear and tear Making a claim Claims must be made by contacting IPSES office within the guarantee period Please contact IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI Italy Tel 39 02 39449519 39 02 320629547 Fax 39 02 700403170 http www ipses com e mail support ipses com Limitation and Statutory Rights IPSES makes no other warranty guarantee or like statement other than as explicitly stated above an
28. D 1 5 j ESI ice elechonici scientific electronics f B P LOS es CARD DESCRIPTION WEB IO card is shown in the picture below in the upper part of the card the sixteen outputs are divided in two groups of eight numbered from 0 up to 7 on the card serigraphy and similarly in the lower part of the card there are the sixteen inputs numbered and divided in the same way OUT15 OUT8 OUT7 OUTO POWER CONNECTOR J2 M dal l f a JUMPER J1 LEDs from 5 to 20 LED D2 LED D3 LED D4 LEDs from 21 to 29 Nii ia INO IN7 ETHERNET PORT Picture 1 WEB IO card Description of the LEDs D2 Green LED Status LED see relevant paragraph D3 Green LED Status LED see relevant paragraph D4 Red LED Status LED see relevant paragraph D5 RedLED OUT 15 activated Red LED OUT 14 activated Red LED OUT 13 activated D8 Red LED OUT 12 activated D9 Red LED OUT 11 activated D10 Red LED OUT 10 activated D11 RedLED OUT9 activated D12 Red LED OUT 8 activated D13 Red LED OUT 7 activated D14 Red LED OUT 6 activated D15 Red LED OUT 5 activated IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY pann PS ES Tel 39 02 39449519 Fax 39 02 700403170 T i es M ipses com e mail info ipses com A ee J scientie electronics taw oj l f 4 ls O d WEB IO USER MANUAL AT P S E 3 Red LED OUT 4 activated Red LED OUT 3 activated Red LED
29. ES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 T ice nEEC elech B pet ipses com e mail info ipses com 1O 1 5 j N scientific electronics Iv f Te P LOS es DEMO SOFTWARE A CD with a demo software is provided with the card This demo software for Windows O S based on telnet service allows to manage the main functions of WEB IO To use this software it is necessary a telnet communication is not already opened on the card while a http communication service can exist simultaneously with This software allows to manage up to 100 WEB IO devices simultaneously connected to an Ethernet network At the software start up the program shows a windows Picture 23 where it is possible to initialize the connection of the devices managed through the software To open the connection with a card insert its P address and its telnet Password in the relevant fields then click on the Connect button After few seconds if the connection is successfully opened the IP address password and serial number parameters of the board will be shown on Connected devices table otherwise an error message will be shown in the Operation message indicator The Start Program button will be enabled only when the connected device list will contain almost one connected device It is no possible to add other devices once the initialization phase is terminated to do this close the program and rest
30. I IN12 INT3 IN14 INIS 9070700970799779099 Acquisition Made Automatic 17 Polling Time s wi 13 0 Picture 24b Automatic acquisition mode of the inputs and the outputs IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY eo gt PS ES Tel 39 02 39449519 Fax 39 02 700403170 tA http www ipses com e mail info ipses com 49 1 5 j ESI core elechonici scientific electronics li Te P LOS exse The objects in the purple section see Picture 24a allow to configure masks and filters for PLC functions Clicking on the relevant square LED of an output a pop up window will appear as shown in Picture 25 For each output the square LED is on only when almost an input is masked so the PLC function is enabled otherwise it is off and the PLC function is disabled The Disable all PLC button resets and stores all masks for each output without modifying any filter INO INT IN2 IN3 INA INS ING IN INE Input Filter ox Gal Ga O Ga Gl Gk CO GGG InputMask O M M o iv irj iw ir ir M mw ir iw iv i I Picture 25 mask and filter PLC configuration pop up window When the pop up window is opening the mask and filter configuration currently stored for the selected output is shown If an input mask is enabled it is possible to modify its filter status too otherwise the last one is dimmed To modify a filter status click on the relevant square LED If all inputs are not masked the enable disabled squa
31. IO 30 DIN WEB IO T 30 DIN WEB IO control card with temperature sensor mounted on a universal support for DIN rail RTCLOG External module with Real Time Clock and Log Memorv ETH CABLE Ethernet cable to connect the card TECHNICAL FEATURES Power supply external from 5V up to 9V continuous current for WEB IO model and from 7V up to 32V continuous current for WEB IO 30 model Maximum current consumption 240mA 5V 250mA 12V Working temperature from 0 C up to 60 C Storage temperature from 40 C up to 85 C Interface toward PC RJ45 Ethernet connector Card dimensions 160 x 100 x 20 mm 6 30 x 3 94 x 0 79 inches Inputs sixteen optocoupled inputs reciprocally isolated in two groups of eight Maximum applicable voltage 36V Input Impedance 2 5Kohm Logical LOW level lt 1V Logical HIGH level gt 2 5V Outputs sixteen optocoupled outputs reciprocally isolated in two groups of eight in an open collector configuration Maximum output voltage 36V Maximum output current 150mA Protection optocouplers with 2 500Vams maximum operative isolation voltage Temperature sensor Resolution 0 0625 C Accuracy 1 C max from 25 C to 65 C 2 C max from 40 C to 25 C and from 65 C to 85 C 3 C max from 55 C to 40 C and from 85 C to 125 C Tel 39 02 39449519 Fax 39 02 700403170 http www ipses com e mail info ipses com 10 il 5 j N 57 IPSES S r l Via Suor Lazzarotto 1
32. Input 7 Input 8 Input 9 m Label I O 10 Label I O 11 Label I O 12 Label I O 13 Label I O 14 Label I O 15 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Copyright 2009 11 IPSES S r l www ipses corn Internet Modalit protetta attivata far RI y Picture 11 I O Label configuration page The O Label Configuration page shown in Picture 11 allows to assign an user defined label to each input and output Each label can have a maximum length of 10 characters If the freezing function for http page commands is enabled the button is disabled The e mail generated by the board as described following contain the detailed I O status each of them identified from the label defined in this page The label fields are loaded with the currently stored strings IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 Fax 39 02 700403170 http www ipses com e mail info ipses com 2D 1 5 j N Dl PS ES acera elec hordas scientie electronics m ud I M b Q5 Lbies T WEB 10 Application Control provided by IPSES S r l Windows Internet Explorer fornito da IPSES S r eo ol X l wa del QU Se httn 192 168 0 16 email index htm EX x Google 39 Effettua la ricerca gt B m de gt Condividi E amp Ap Controllo 3 Traduci S Compila
33. LIO Select Target Board WEB IO WiFi xi TCP IP Parameters configuration IPaddress 192 1168 0 16 Configuration Subnet mask 255 255 255 1 0 103 ETE n a Gateway address 192 1168 0 4 PimayDNS o fo 10 Jo l 5 i Secondary DNS o Jo Jo Jo Reboot enable WiFi parameters Enable WiFi config Y SSID WEB AP Authentication WEP 104bit ASCI zd Key www ipses cot m Board Section Serial number Remote IP address UN E Board status Status Picture 31 WEB IO Address Configurator software control panel IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 Ae M ipses com e mail info ipses com kf e ij aj ire eec WEB IO USER MANUAL d PS ES scientific electronics To send the new TCP IP address configuration click the Start button during the communication with the card the Configuration LED is on To exit the software click on Quit button If the communication handshake to the card is successful the Serial number and Remote IP address fields in the Board Section are filled respectively with the current S N and IP address of the card as shown in Picture 32 The Board status field shows a message about the progress of the configuration status WEB O TCP IP Address Configurator IEP SES E L Picture 32 Confi
34. OUT 2 activated Red LED OUT 1 activated Red LED OUT 0 activated Green LED Vhign applied at IN 7 Green LED Vhign applied at IN 6 Green LED Vhign applied at IN 5 Green LED Vhign applied at IN 4 D25 Green LED Vrigh applied at IN 3 D26 OmenlEDVesapledalIN2 D28 GmenlEDVwsapledallIN OOOO D29 Green LED Vi applied atIN 15 D30 GreenLED Vngn applied atIN A D31 Green LED Vin applied atIN 13 D32 Green LED VaappiedatIN 2 CSCS D33 Green LED VaappiedatIN T CSCS D34 GeenlEDVweappledalINIO SSCS D35 GmenlEDVweappledalIN OCS D36 Green LED Vn applied atIN 8 Description of the jumper JI Hardware reset with factorv parameters restoration Address Configuration mode see paragraph ADDRESSES CONFIGURATION Description of the connectors for the expansion module J2 J3 Connectors for RTCLOG module 10 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY i Tel 39 02 39449519 Fax 39 02 700403170 2D 1 5 j QC nERC tie irorw i http www ipses com e mail info ipses com N f i b f Os WEB IO USER MANUAL QIP SES OUTPUTS The sixteen outputs are completely opto isolated both among them in two groups of eight and towards all signals on the device Here below there are the diagrams of two typical connections of external device to WEB IO card in the first case Picture 2a the card will manage directly some loads with maximal current of 150mA for each output In t
35. P IP protocol the protocol configuration parameters can be modified only from http service To validate these changes a password named http service password is required Similarly to access telnet service an authentication password named telnet service password is required Both passwords are case sensitive alphanumerical strings with a valid length included between 1 and 8 characters The default value for both is ipses and it can be modified only from the relevant service The SNMP service supports both V1 and V2c versions The last one implements a community based service access which is an authentication access method It is possible to set up to 3 different communities both for read and write operations The default communities are Write Community private write public Read Community public read 7 Each specified community can be 8 chars maximum length if none community is specified the access to the pertinent service read and or write is blocked The SMTP client allows to send e mails alerts to different user configurable recipients based on status inputs change events This service can be configured only by http pages ib ib ADDRESSES CONFIGURATION The following table shows the default configuration parameter of each board Security Level 0 4 The addresses for Primary DNS server and Secondary DNS server must be modified according to the addresses assigned from the network s pr
36. TC 0200 Copy to RIC Remote Control i Configuration j Manual Time i Save to RIC TCP IP RTC Time Mon 6 Jun 2011 12 34 47 Configuration E Security Settings _ Log Memory Status Log Enabled Overwrite Forbidden Resume Log Memory Occupation 10 Bootloader Mode Log Memory Option V Enable Log Memory O Overwrite mode 9 Stop to end Info Address to ping Ping response Copyright 2009 11 IPSES S r l www ipses com Picture 19 Real Time Clock and Log Memory configuration page RTCLOG module Picture 19 shows the configuration page of the Real Time Clock and the Log memory available on the optional RTCLOG module The upper side of the page is dedicated to the configuration of the parameter necessary to obtain the current date and time from Internet like the SNTP Simple Network Transfer Protocol server address shown in the SNTP Server field The Save button allows to store the new SNTP address inserted in the New SNTP Server field The Time Zone Option allows to manually assign the GMT displacement and to manage the Legal hour condition The Submit button sends these selections to the board that will update these fields and the date shown in the Internet Time field If the date from the network is not available the Date not available message will be shown in this case make sure the internet connection is on and active the DNS servers addresses are valid and the SNTP server
37. Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 L B pet ipses com e mail info ipses com 210 1 EI j N i La i echoed scientific electronics Te P LOS es GENERAL FEATURES WEB IO is a control unit integrated on a European Card Format 160 x 100 mm 6 30 x 3 94 inches equipped with Ethernet interface The card needs an external power supply to operate There are two available version with power supply from 5V to 9V range and with power supply from 7V to 32V range ETHERNET WEB IO can check sixteen optocoupled inputs and drive sixteen optocoupled outputs Both are reciprocally isolated in two groups of eight The control and the configuration of the device are achieved through Ethernet interface thanks to an http browser or a MIB browser or a telnet client or using the demo software provided with User can set the status of each output at the power up this status will be saved in a non volatile memory The card allows to perform a firmware upgrade using directly the server implemented on it so there is not the necessity to use an external hardware or software component Beside an optional external module RTCLOG equipped with Real Time Clock system and static memory for log function is available IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 Fax 39 02 700403170 v wa DI PS ES B pet ipses com e mail info ipses com 2
38. a Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 39 02 320629547 Fax 39 02 700403170 e mail info ipses com support ipses com IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY 473 Tel 39 02 39449519 Fax 39 02 700403170 LA PSES ni ipses com e mail info ipses com 210 1 EI j N
39. address is valid To perform this check you can use the ping function available at the end of the page When you push the Ping button the card try to ping the addresses inserted in the Address to ping field 35 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY ya PS ES Tel 39 02 39449519 Fax 39 02 700403170 Ha http www ipses com e mail info ipses com 49 1 5 j N acera elec hordas scientific electronics ER o P IOS momma ess The RTC Time can be assigned in two ways from the Internet with the Copy to RTC button or manually in the format DD MM YYYY HH MM SS with the Save to RTC button If the Internet time is not available the Copy to RTC button is disabled if the external module is not present also the Save to RTC button is disabled The lower section is dedicated to the Log memory configuration parameters Log Memory Status shows the enable disable logging status and the writing mode set on the board These parameters can be modified in the Log Memory Option field and send with the Submit button The Reset button erase all the memory content without changing the current settings The Log Memory Occupation field shows the percentage of memory filling at the time of this writing not all browsers support the display of the metric bar If the external module is disabled the External module disabled message is shown and the Submit and Reset buttons are dimmed The configuration of the log parameters
40. art it repeating the initialization steps The Quit Program button allows to close the software without opening the main window Connected devices IP address Password Seral Number Ea Operation message Picture 23 Initialization connection panel of the demo software Picture 24a shows a snapshot of the main window of the software To enable the control of one of the initialized cards it necessary to select its Serial Number from the Device S N ring menu The selection of a new board allows to automatically update the inputs and outputs status and to update Firmware Version and IP Address fields The temperature indicator is updated only if the card is equipped with the relevant sensor otherwise the indicator will be disabled 46 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY AX Tel 39 02 39449519 Fax 39 02 700403170 M y 21 PS ES http www ipses com e mail info ipses com 090 1 5 j N ier piec homei WEB IO USER MANUAL AJ P S E S scientific electronics OUTO OUTI OUT2 OUT3 BUTA OUT5 OUT6 OUT OUTS OUTS OUTIO OUTI GUTIZ OUTI3 OUTI4 OUTIS pw nw ww ew c cw Ww wai Or OUTO OUTI OUT2 OUT3 OUT4 OUTS OUTE OUT OUTS OUTS OUTIO OUT11 DUTIZ OUTI3 0UTI4 OUTIS o OQ C O 9 Oo Oo BS OQ aa aaa aa aa a l menie Acquisition Mode Manual Bed Output Device S N 2009000 b ING IN INS INS INTO INT IN12 INi3 INIA INIS c o0 oo o 99 Ac
41. associated Boolean logic control For example as shown in picture above user can set the output n 3 to switch on when inputs 1 2 3 5 9 13 14 are high and inputs 6 15 are low other inputs are don t care with AND logic selected To do this select the desired output through the Select Output ring in the upper part of the PLC configuration panel In the Saved Status section will be shown the filter and mask values actually stored for the selected output Clicking on LEDs and checkboxes of the Set Status section is possible to set the new inputs filter and mask values respectively If an input is not masked it will be not considered from the logic function independently of its filter status selection The Logic ring allows to select the Boolean logic to perform the input filtering AND OR To make the new values operative click on Save PLC Setting When the PLC function is enabled on an output the output status will be set according the customizable input status For this reason it will be not possible to manually set that output until the PLC function is enable To do this user needs to disable the PLC function To disable the PLC function on an output all inputs must be not masked the relative item in the Set output ring will became grey otherwise it will remain blue The Disable All PLC Mask button in the lower part of the PLC panel allows to reset and store the mask of each output without modifying the filter and logic settings If the
42. ation I O Label SNMP Community Configuration Panel Configuration po aes E mail l Read Community 1 public Configuration i Read Community 2 read Read Community 3 Remote Control Configuration TCP IP Write Community 1 private Configuration i Write Community 2 write Resume Write Community 3 public Bootloader Mode Info Save Communitv Configuartion Copyright 2009 11 IPSES S r l www ipses com Internet Modalit protetta attivata fg y 100 Picture 10 SNMP Community configuration page The SNMP Community Configuration page shown in Picture 10 allows to set the read and write communities for the SNMP server V2c Each community can be a case sensitive alphanumeric string with a maximum length of 8 characters If you do not want to set one or more communities leave the extra fields blank If all fields are left blank it will be impossible to access to SNMP server The queries run in the MIB browser can be evaluated from the SNMP server only if the community with which the request is generated is included in the configuration list The button Save Community Configuration stores the settings on the board If the freezing function for http page commands is enabled the button is disabled 25 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Ed PS ES Tel 39 02 39449519 Fax 39 02 700403170 gt http www ipses com e mail info ipses com 2D 1 5 j N acera el
43. before attempting to install It is the responsibility of the technician to undertake all the safety rules provided by the law during the installation and the use of this device For any information which is not contained in this guide please contact IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI Italy Tel 39 02 39449519 39 02 320629547 Fax 39 02 700403170 http www ipses com e mail support ipses com IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 439 02 39449519 Fax 439 02 700403170 y ql n aa ipses com e mail info ipses com 210 1 EI j N WEB IO USER MANUAL AJ P S E S scientific electronics p Oe TABLE OF CONTENTS ALO NU glo Le na m m 6 GENERAL FE ATORE uned aiii anta cda pedis tan 8 A C6 e M 9 OG MOD LE DESCUIDO c A mo watslahetserstunebnes 14 OPERATION TODE mr 15 IAS A A 15 POWER OPRET a IUUD MODA cr eee rere eee err M NUM IM 16 ETERNO DU n 17 AA a AA o A A ee iUa 18 ADDRESS CONFIGURAIEON eee 18 REMOTE CONT OLGE AN IU b ME 20 gros 21 frc ril d 38 SNS E VES 42 PROBLEM SRE OLUTION ats ga e ee i A Er e E a EEE r EAE E 45 KEOS f AT E E UM 46 TCP IP ADDRESS CONFIGURATOR SOFTWARE cusco 53 gisi B b OT CODE mt of ize e LIFE A 00 e naa of Fa MODEL m M 99 Sepp re te etn eee re E re ee ee ee eee rT 63
44. box allows to insert a new http password in the New Password and Confirm New Password fields The Load Factory Configuration button allows to restore factory parameters excepted for the http password that will not be modified 30 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY LM PS ES Tel 39 02 39449519 Fax 39 02 700403170 AD http www ipses com e mail info ipses com 7 1 5 j N acera elec hordas gt A ls O L KA KJDIPSES scientific electronics At the end of the page is available the Ping function which allows to verify the connection between card and inserted address If the communication is lost the ping section shows the following error message Connection to WEB IO board was lost Warning if the saved parameters are invalid or they could not be resolved in your network you will lose the communication To restore all default parameters follow the procedure described in ADDRESSES CONFIGURATION paragraph WEB IO Application provided by IP E E x e Ned Y http 192 168 0 16 security security htm Sd BAAL Google p m J Effettua la ricerca 7 o esu Condividi Ei Ap Controllo 3 Traduci f Compilazione autom gt gt g Entra i x Google gir Preferiti 3 Siti suggeriti vg Raccolta Web Slice v e WEB IO Application Control provided by IPSES S fi nm Bh v Pagina Sicurezza Strumentiv iv Index Sta
45. button is disabled 22 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax 39 02 700403170 Ue http www ipses com e mail info ipses com 49 1 5 j N cere alechonici scientific electronics 2 Je P Oo ens T WEB 10 Appl cation Control provided by IPSES S r l Windows Internet Explorer fornito da IPSES S r Qs http 192 168 0 16 timeout timeout htm y SE x Google 3 Effettua la ricerca 7 ib S H Condividi E amp Ap Controllo 7 Ey Traduci I Compilazione autom gt Ae 7 J Entra gt iy Preferiti qis Siti suggeriti v f Raccolta Web Slice amp WEB 10 Application Control provided by IPSES S ft 3 de v Paginay Sicurezza y Strumentiv iv WEB IO Control Panel Index Timeout Configuration Startup Configuration Serial number 2011000 Timeout Firmware version v01 05 0000 Configuration A MM Timeout Configuration Panel SNMP Community ETT St I O Label Configuration 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 E mail Digital Output BIE 2 9 2 Configuration Timeout 30 sec Remote Control i Configuration TCP IP Configuration U12 3 4 Si 56 Y S 9 10 Hi 1239 24 15 Digital Output 6 e e e eo Resume ii Ki mu _ Timeout No timeout Save Timeout Setting Info Security Settings Copyright 2009 11 IPSES S r l www ipses com Inte
46. d in Confirm New Password field it could be any alphanumeric strings with a valid length between one and eight characters The Enable Change Password checkbox enables the Set New Password button The result of the modifying command will be shown in the Last Command Sent field in the lower part of the main panel while if an error is generated by the password validity check operation the error message will be popped up 50 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY m PS ES Tel 39 02 39449519 Fax 39 02 700403170 th 2 http www ipses com e mail info ipses com 72 1 5 j N Iceri electonici scientie electronics Pe f ju b Q5 LL cst mm A RA E Vi Advanced Commands Enable change password MAC Address 00 04 A3 1E A7AC New Password Hostname WEBIOBOARD password IP Address 192 168 0 16 i Ee password Set New Password Subnet Address 255 255 255 Gateway Address 192 168 0 4 DNS Address 193 70 152 15 DNS Address 193 70 152 35 General Board Parameters Fimware version v01 02 0000 Stack Version v5 00 Picture 28 Advanced Command window The Log Panel window shown in Picture 29 which can be opened by the Log Commands button allows to read and erase the Log memory A progress bar indicates the current memory occupation while the Overwrite memory LED turns on only when the memory is full and the new data overwrite the older ones The Read
47. d this Guarantee is given in place of all other guarantees whatsoever to the fullest extent permitted by law In the absence of applicable legislation this Guarantee will be the end user s sole and exclusive remedy against IPSES General Provisions IPSES makes no express warranties or conditions beyond those stated in this warranty statement IPSES disclaims all other warranties and conditions express or implied including without limitation implied warranties and conditions of merchantability and fitness for a particular purpose IPSES s responsibility for malfunctions and defects in hardware is limited to repair and replacement as set forth in this warranty statement IPSES does not accept liability beyond the remedies set forth in this warranty statement or liability for incidental or consequential damages including without limitation any liability for products not being available for use or for lost data or software With the exclusion of shipping costs for and from IPSES s development office IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY gt IPS ES Tel 39 02 39449519 Fax 39 02 700403170 L T iC nEEC tech ct B pet ipses com e mail info ipses com 090 1 5 j N cientilic electronics lv Te P LOS oss WARNING ELECTRICAL DEVICES COULD DAMAGE EQUIPMENT OR PROPERTY OR CAUSE PERSONAL INJURY This guide contains instructions and technical features of the WEB IO Control Unit Read with attention
48. der Mode Address to ping 192 168 0 17 Ping response 192 168 0 17 2 ms Copyright amp 2009 11 IPSES S r l www ipses com Internet Modalit protetta attivata fa y 10 Picture 13 Remote Control service configuration page The Remote Control Configuration page shown in Picture 13 allows to set the configuration parameters for the Remote Control service In the upper section of the page the current MAC and IP addresses of the board are displayed To establish the communication between two A and B WEB IO family boards user must configure the following parameters in both systems MAC Address of the destination board P Address of the destination board UDP port for incoming packets Local UDP Port UDP port for outcoming packets Remote UDP Port The Local Port of the board A must be set as the Remote Port of the board B and vice versa The user must ensure that the UDP ports selected are not reserved or used by another service The Enable Remote Control Communication checkbox enables or disables the service The Save Configuration button stores the fields and the option in memory If the freezing function for http page commands is enabled the button is disabled In the lower section of the page is shown the status of the service thanks to the Remote Control communication status LED If the service is disabled the LED is grey If the service is enabled but no incoming packets are detected the LED is yellow If the
49. e mode the LED configuration is the following one LED D2 LED D3 LED D4 Status Description Blinking Board correctly configured and operative Blinking Blinking Hardware resetting to factory settings or software TCP IP address configuration Blinking telnet password modifying If D2 or D3 are Off there is respectively an hardware or a firmware initialization error In Bootloader mode D2 D3 and D4 LEDs light up repetitively in sequence until one remains in this status IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY gt IPS ES Tel 39 02 39449519 Fax 39 02 700403170 L y ciente elect B pet ipses com e mail info ipses com 210 1 EI j N scientific electronics Te P LOS es POWER SUPPLY The board is equipped with a connector see Picture 1 at page 8 the connector is labeled as POWER SUPPLY which allows to connect an external voltage supply to power the board its value must be included from 5V up to 9V or from 7V up to 32V based on the model The voltage supply can be used also as Power Supply as indicated in Picture 2b and 3a by these way the galvanic isolation of the board between I O and control logic will be lost so the GNDs must be connected together to avoid irreversible damage of the card WARNING The maximum supply voltage must not exceed 9Vdc 32Vdc depends on selected model in case of use of higher voltage the components of the board may damage irremediably It
50. ec bordes KJDIPSES scientific electronics Qu li S b Qs ww J Effettua la ricerca 7 o eu Condividi E amp Ap Controllo 3 Traduci S Compilazione autom gt 7 gir Preferiti 3 Siti suggeriti v g Raccolta Web Slice v e WEB IO Application Control provided by IPSES 5 fi Tho E 11 dm y Pagina Sicurezza v Strumentiv yv z IPSES Scientific Bectronics Startup Configuration Timeout Configuration PLC Configuration SNMP Communitv Configuration I O Label Configuration E mail Configuration Remote Control Configuration TCP IP Configuration Security Settings Resume Bootloader Mode Info I O Label Configuration Panel Serial number Firmware version This page allows to assingn an user defined label to each I O which will be used in the mail body Each la m A AAAA 4 4 A 2 WEB IO Control Panel 4 2011000 v01 05 0000 bel can be a maximum of 10 characters E i I O Label Panel Label I O 0 Label I O 1 Label I O 2 Label I O 3 Label I O 4 Label I O 5 Label I O 6 Label I O 7 Label I O 8 Label I O 9 Inputs Outputs Output 0 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Output 9 Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input
51. ed the command sent to the board will not process The http page shown by the board as response to these commands is a blank page the user must take care to digit correctly the URL addresses and the parameters IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 Fax 39 02 700403170 Dl PSES eres ghpctronica B pet ipses com e mail info ipses com 49 1 5 j N he f i P OS sts OPTIONAL MODULE RTCLOG On request WEB IO card can be equipped with the RTCLOG optional module In this case the board firmware does not implement the SMTP client service because the input status change are now saved into the log memory Accordingly to the new firmware the O Label Configuration and E mail Configuration pages are removed from the web server while the RTC amp Log Configuration page is added to allow to manage RTCLOG module y 77 WEB IO Application Cont C 192 168 0 16 time time htm oA Raccolta Web Slice Siti suggeriti Altri Preferiti ld WEB IO Control Panel Real Time Clock amp Log Memory Configuration Startup Configuration Serial number 2011020 Timeout Firmware version v01 06 000R Configuration PLC Configuration SNTP Server europe pool ntp org RTC amp Log New SNTP Server Configuration E SNMP Community Time Zone Option GMT 1 00 x Y Legal time Submit Configuration i Internet Time Mon 6 Jun 2011 12 34 47 U
52. f 10mV and are calibrated one by one Each input and output status can be read by a web browser or a telnet client at any moment besides the status of digital inputs and outputs it is shown directly on the board thanks to LEDs fixed on WEB ADIO WiFi Input output Card with 8 analogical inputs 8 digital inputs 8 analogical outputs and 8 digital outputs Ethernet and WiFi interfaces integrated web telnet and SNMP servers WEB ADIO WIFI is a card to manage 8 optocoupled digital inputs 8 j q SCSTCSEOSSDOSSSSSTIIIS o analogical inputs 8 optocoupled digital outputs and 8 analogical de we Hr ECCE outputs with Ethernet and WiFi interfaces equipped with a web a g o MEINEN i os telnet and an SNMP servers The web server allows to connect and s SERE Te aes RN to manage the card using any web browser i e Internet Explorer and Firefox with no needs to install a software on your PC Beside the card can be connected directly to a switch or to a router with no need to use a PC The board is available with built in antenna or with ultra miniature coaxial U FL connector for external antenna connection It is also possible to develop a customized software managed by telnet service The analogical inputs and outputs have an operative voltage from OV to 10V with a resolution of 10mV and are calibrated one by one WEB ADIO WiFi can be directly connected to PLC or to analogical transducer to input devices from operator and to other I O sy
53. f requested records from the last one The next picture shows an example of the answer related to the request of the last 10 records Mon 6 Jun 2011 11 32 48 0x0001 0x0001 Mon 6 Jun 2011 11 32 48 0x0000 0x0001 Mon 6 Jun 2011 11 32 49 0x0001 0x0001 Mon 6 Jun 2011 11 32 49 0x0000 0x0001 Mon 6 Jun 2011 11 33 10 0x0001 0x0201 Mon 6 Jun 2011 11 33 11 0x0000 0x0201 Mon 6 Jun 2011 11 33 11 0x0001 0x0201 Mon 6 Jun 2011 11 33 12 0x0000 0x0201 Mon 6 Jun 2011 11 33 12 0x0001 0x0201 Mon 6 Jun 2011 11 33 12 0x0000 0x0201 Each record is formatted as following data input output br PP 36 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY N PSES Tel 39 02 39449519 Fax 39 02 700403170 qw HI scie nic electronics B pet ipses com e mail info ipses com 1O 1 5 j N cientilic electronics he LOS GRIPS The input and output status is expressed in the hexadecimal notation where the I O 0 is the LSB and the I O 15 is the MSB The terminator character of each record is the html break line tag lt br gt The time necessary to populate the answer page is proportional to the number of requested records so the request of the whole memory content if it is effectively full needs some second to be elapsed If the memory is empty it will be returned the Memory empty string while if the RTCLOG module is not connected o not recognize it will be returned the
54. from IPSES website at the following address htip www ipses com PDFAPSES engineering_problem_report pdf Verify the correct power supply and operation of the board see status LEDs Verify the correct connection of the network cable both on board and LAN side network card switch and verify if the board is visible from the network Verify the compatibility of board addresses IP subnet gateway in the operative network If there is no compatibility ensure to configure them properly Try to ping the IP address of the board Make sure the IP address in the URL field is correct http service Verify there are no more than 3 simultaneous connection opened on the same board http service Make sure the password inserted in the TCP IP Configuration page is correct http service Make sure the telnet communication port is number 23 telnet service Make sure the telnet access password is correct it is case sensitive telnet service Verify there is no telnet communication already active on the board via telnet client or demo software telnet service Verify the DNS server addresses Verify the address entered with the ping function http service Check the RTCLOG module is properly connected the module must be inserted or removed only when the WEB IO card is not powered on Check the MIB browser is set properly through the mib correct file loading and communities settings SNMP service IPS
55. ge is performed every time the module is properly connect to the card The log memory can store up to 4093 sample as described in the http Server paragraph Picture 5 RTCLOG module WARNING Pay close attention to connect properly pins module and expansion receptacles card Otherwise the module and or the card may be damaged irremediably The RTCLOG expansion module must be inserted or removed only when the card is not powered on Otherwise the module or the card may be damaged irremediably 14 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY AX 1 PS ES Tel 39 02 39449519 Fax 39 02 700403170 Es http www ipses com e mail info ipses com N i ipriifi elec iONW A ientific electronics pr l 916 ls QU Ves COIPSES OPERATION MODES The firmware of the board implements two different modes as specified in the following table Mode Description This is the normal mode During this status the control of the outputs and PLC and Timeout Operative functions are fully available The interaction with the board can made by web browser MIB browser telnet or demo software Using this mode the board waits for a firmware upgrade or a return to Operative mode Bootloader In this status all the outputs and PLC and Timeout function are disabled The interaction with the board can only made by a web browser STATUS LED D2 D3 and D4 LEDs indicate the status of the system In Operativ
56. guration successfully completed If a communication error occurs the Serial number field is empty and the Remote IP address field shows an invalid IP address 0 0 0 0 while an error message is shown in the Status section and the Start and Quit buttons are disabled until the error is reset as shown in Picture 33 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY 99 Tel 39 02 39449519 Fax 39 02 700403170 KJDIPS ES http www ipses com e mail info ipses com TS J 1 j o E di y yx Alo all 7 P WEB IO WiFi TCP IP Address Configurator Picture 33 Error during configuration To configure another card perform the necessary hardware set on the board then type new addresses and click on the Start button Note if you are still using Windows Vista or Windows 7 on your PC your operative system could ask you to unlock a firewall restriction when you click on the Start button Confirm the unlocking of the firewall restriction otherwise the communication of the software via Ethernet will be interdicted from the operative system 56 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY f PS ES Tel 39 02 39449519 Fax 39 02 700403170 http www ipses com e mail info ipses com k 5 xs pe f i b LOS LL es PRODUCT CODE WEB IO WEB IO control card with power supply from 5V to 9V WEB IO T WEB IO control card with temperature sensor and power supply from 5V to 9V WEB
57. h the jumper J1 inserted will restore the factory parameters POWER SUPPLY JUMPER J1 III LED D2 LED D3 LED D4 ETHERNET PORT Picture 30 WEB IO card IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 lt 9 i UL B echoed B pet ipses com e mail info ipses com 9 1 j ESI Ts b Oe WEB IO USER MANUAL C Or 2 IP SES ADDRESS CONFIGURATOR CONTROL PANEL The WEB IO Board Address Configurator control panel shown in Picture 31 allows to configure both TCP IP parameters like IP address Subnet mask address Gateway address and Primary and Secondary DNS server addresses and wireless parameters to connect to the Access Point The modification of these last ones can be enabled by the user after a WiFi model card was previously selected Before to set the new parameters the user should properly select the target card through the Select Target Board ring the wireless parameters will be enabled or disabled based on selected model Every field is saved on the board it is important to compile each field with correct values The Reboot enable checkbox allows to perform a software rebooting of the card after the address configuration is successfully ended If the configuration process ends successfully the status LEDs D2 and D3 on the board will flash for about one second F Address Configurator vi WEB IO WiFi TCP IP Address Configurator
58. he current status of each inputs and outputs Output command buttons labeled from 0 to 15 drive the outputs each button pressure set or reset the relative output If the freezing function for http page commands is enabled these buttons are disabled The filling colors used in the http page are correspondent to the LEDs mounted on the card Temperature field surrounded in green shows the measured temperature by the sensor if the board is not equipped with the temperature sensor a message is displayed The Remote Control communication status LED surrounded in yellow shows the current status of the Remote Control service If this service is disabled the LED is grey else if the service is active and the communication with another WEB IO family card is established the LED is green instead if the communication fails the LED is yellow In both of the last two cases the Output command buttons are disabled If the communication is lost the current page shows the following error message Connection to WEB IO board was lost T WEB 10 Application Contro provided by IPSES S r l Windows Internet Explorer fornito da IPSES S r ics m QUSE hitp 192168 016 startup startup htm 0000 M e m x Google 39 Effettua la ricerca 9 m Condividi E amp Ap Controllo 3 Traduci Compilazione autom gt Ap Ly Entra vy Preferiti f E Siti suggeriti 8 Raccolta Web Slice E A
59. he second case Picture 2b the card is connected to a high impedance device i e the inputs of a PLC Power Supply vaux GND LOAD A LOADS 7 LOADS 3 a ogam LOADH Power Supply 5V 3BV Picture 2b diagram of the output connections connection to a high impedance device Output status is displayed by LEDs placed near every connector LED from D5 to D20 showed in Picture 1 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax 39 02 700403170 i Ms ui ipses com e mail info ipses com scientiic electronics 19 1 5 j N PULIS ens INPUTS The sixteen inputs are completely opto isolated both among them in two groups of eight and toward all signals on the device We suggest to connect inputs following one of the two diagrams displayed below Picture 3a use this way in case inputs have to detect the pressure from a switch or an open collector output Picture 3b use this way in case inputs are directly controlled by a voltage g U0I 4 CN a E Power Supply 5V 36V Picture 3a diagram of input implementation detection of the pressure from a switch or an open collector output Y OU 2 LJ Nc IS Picture 3b diagram of input implementation inputs directly controlled by a voltage Input status is displayed by LEDs placed near every connector LED form D21 to D36 showed in Picture 1 IPSES S r l Via Su
60. ion PLC Configuration 00 04 A3 00 00 01 SNMP Community Configuration Host Name WEBIOBOARD I O Label Configuration ESI IP Address 192 168 0 16 E mail i Subnet Mask 255 255 255 0 Configuration i aces Gateway Address 192 168 0 4 lad Lun Primary DNS 193 70 152 15 ontiguration Secondary DNS 0000 s Resume Bootloader Mode Security option Configuration Info Enable Change Password New http password IDMIIIIII Confirm new http password e http Password This button allows to reload the TCP IP factory configuration settings in the form fields excluded the password Load Factory Configuration Address to ping www ipses com C Ping Ping response www ipses com 19 ms Internet Modalit protetta attivata ev QS Picture 14 TCP IP protocol and http password configuration page TCP IP Configuration page shown in Picture 14 allows to modify some TCP IP protocol parameters and the http password of the board The hostname can be maximum 16 alphanumeric case insensitive characters length To modify and save these parameters it is necessary to insert a valid http password then press the Save Configurations amp Reboot button If the password is invalid or data processing fails configured parameters will not be saved and you will be redirect to an error page To came back click on the appropriate link The Enable Change Password check
61. it Bl MC BALL ACARI ACC HCE B Set Deactive Output x 8 15 A single all outputs gt gt AA SLIxxxxxxxxxxxxxxxx l or ADA SLIxxxxxxxxxxxxxxxxl Set Outputs Status ix HN 1 offon status Era A AS Read Temperature Sif IC BICC iC ABR fil BICC IC SRC SCA a BI AC SS SC Read Startup outputs SP S xxxxxxxxxxxxxxxxl or SPD SIxxxxxxxxxxxxxxxxl Set Startup outputs IB 151 ix B i off on status Read Timeout status BH 15 status set time Set Timeout Time ix b 8 Set Timeout Outputs H 15 E x H 1 off son status Head PLO tMask Filter ty 68 15 output Set PLO Mask y 6 15 output x H 1 off on IH I15 5 Set PLC Filter y 68 15 output x H i offon IB 115 Set PLC Logic amp y H 15 output x H 1 AND ORS Read status of advise on inputs change Disable Enable advise on inputs changetx 6 1 offon Read the Fast Response Mode Status Fast Response Mode x 6 1 offon status Remote Control Status Change telnet passuord bil f tal Balal B A a CC SC Se NENE Quit Pe Re a ee ee a r a Help IM S xxxxxxxxxxxxxxxxl PLGu HMIxxxxxxxxxxxxxxxxl PLGu FE xxxxxxxxxxxxxxxxl Picture 20 telnet server access page and help request This service allows to read I O status to read card parameters to manage outputs and Log memory only with firmware that support RTCLOG module All commands are case insensitive 38 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY mc Tel 439 02 39449519 Fax
62. ith variable length related to the typed command The answer to these I O setting commands is x1b 34mdone 1x1b 0 1m The answer is made by a single char 0 Off 1 On The next table encode the timeout time parameter used in TM and TM T x commands 0 Notimeout 2 fOseons 4 mnte 5 5mimutes 6 10minutes NEN NEN DEVELOPMENT OF CONTROL APPLICATIONS WITH telnet PROTOCOL It is possible to develop a control application for the WEB IO board based on telnet Server the user program should be able to manage the strings generated from the server The following are the strings used in the program with a brief description of them Server telnet access string xX1b 2J x1b 31m x1b 1mMWEB IO Telnet Server 1 2 x1b Om r nTo access the service insert the password r nPassword Answer string to incorrect password the telnet socket will be closed r nAccess denied r n r n 40 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY A a P S E Tel 39 02 39449519 Fax 39 02 700403170 km http www ipses com e mail info ipses com IM 1 5 j N Lc er F a elec hi eruit l scientific electronics n P IOS 2L ess Answer string to correct password the command prompt will be shown r n r n x1b 1 32mLogged in successfully x1b Om Press q to quit r n r n Command prompt it is shown after each command executed except CP command r n gt Answer stri
63. l 5 j N scientific electronics f Te P LOS es TCP IP ADDRESS CONFIGURATOR SOFTWARE WEB IO Board Address Configurator provided with the card is a software which allows to configure remotely TCP IP addresses for WEB family IO control units WEB IO WEB IOBOX WEB ADIO WEB IO WiFi WEB ADIO WIFI ETHERNET Oniv for WiFi models it is also possible to configure the wireless board parameters The configuration of the device is achieved through Ethernet interface or only for WiFi models e also with the wireless interface In the last case it is necessary that the card can connects itself to LI Fi the Access Point i e the SSID and authentication parameters must be correct 7 To work properly only one card per time must be set in address configuration mode even if you have more than one board of the WEB family connected WEB IO Board Address Configurator software is able to communicate with every IP address excluded the reserved broadcast address 255 255 255 255 That means it is possible to configure also cards with out of net IP addresses ADDRESS CONFIGURATION MODE To enable the hardware address configuration mode follow the procedure listed below with the WEB IO board already powered on insert jumper J1 see picture below perform the desired software configuration atthe end of the configuration remove jumper J1 Do not disconnect the power supply during the address configuration procedure A supply reset wit
64. n integrated temperature sensor which allows to monitor in real time the temperature around the regulator voltage module Through expansion connectors the card can be interfaced to a RTCLOG Real Time Clock and Logger optional module by this way it can perform a log of the I O states on a dedicated memory WEB IO is available also in box version it is provided with a demo software for Windows environment based on telnet service WEB IO WiFi Input output Card with 16 inputs and 16 outputs Ethernet and WiFi interfaces integrated web telnet and SNMP servers WEB IO WIFI is a card to manage sixteen optocoupled inputs and sixteen optocoupled outputs with Ethernet and WiFi interfaces equipped with a web a telnet and an SNMP servers The web server allows to connect and to manage the card using any web browser i e Internet Explorer or Firefox with no needs to install a software on your PC Besides the card can be connected directly to a switch or to a router by this way it can be accessed by any PC connected to Internet It is also possible to develop a customized software managed by telnet service or SNMP protocol The board is available with built in antenna or with ultra miniature coaxial U FL connector for external antenna connection WEB IO WiFi can be directly connected to PLC to input devices from operator and to other I O systems Each input and output status can be read by a web browser or a telnet client at any mome
65. ng to each invalid command or request x1b 33merror x1b 0 1m UTILITY DESCRIPTION The ElCx Advise on Input Change command allows to enable or disable the printing of the status of all inputs in hexadecimal format every time there is a change of at almost one input The command is disabled by default at every server access The FRx Fast Response command allows to enable or disable the printing of the descriptive strings This utility is useful to write codes in which the program focuses his resource only to process the data received in a synthetic form without parsing all the strings The command is disabled by default at every server access The CP Change Password command is made by three phases in the first one it is requested to insert the new password Ar AnEnter new password Next one it is requested to confirm the new password r nConfirm new password Now if the password match is valid the answer string will be r n r nPassword changed successfully Nn Otherwise it will be r n r nPassword change fails r n The change of the password in telnet does not perform a reboot of the board or the automatic disconnection from the current session on the contrary to what happens in the analogous http service Obviously next telnet access to board here included the use of demo software must be authorized by the new password IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02
66. nt besides it is shown directly on the board thanks to LEDs fixed on On request the card can be equipped with an integrated temperature sensor which allows to monitor in real time the temperature around the regulator voltage module 60 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 439 02 39449519 Fax 439 02 700403170 http www ipses com e mail info ipses com Fach TT LA PS ES core eipchonici scientific electronics M p s YOS san IPSES WEB ADIO Input output Card with 8 analogical inputs 8 digital inputs 8 analogical outputs and 8 digital outputs Ethernet interface integrated web telnet and SNMP servers WEB ADIO is a card to manage 8 optocoupled digital inputs 8 analogical inputs 8 optocoupled digital outputs and 8 analogical outputs with Ethernet interface equipped with a web a telnet and an SNMP servers The WEB server allows to connect and to manage the card using any web browser i e Internet Explorer and Firefox with no needs to install a software on your PC Beside the card can be connected directly to a switch or to a router with no qna need to use a PC l 1 i AAA It is also possible to develop a customized software managed by telnet service WEB ADIO can be directly connected to PLC or to analogical transducer to input devices from operator and to other I O systems The analogical inputs and outputs have an operative voltage from OV to 10V with a resolution o
67. nt parameters The MIB Tree has six branches each of them has several leafs product where to read information about the board Setup where to set the parameters for two different traps inputs where to read input status outputs where to read or set the output status status where to read the PLC and Timeout function status On Off and the measured temperature if available events which contains the variable associated to the Trap s event and it can be read or written Using SNMP server it is not possible to configure the PLC and Timeout functions The Operation selector specifies the request to be sent to the server The answers to reading requests are shown in the Result Table instead to set a parameter it is mandatory to insert the value according to the specified kind in the relevant form of the pop up window For further information about commands and functions consult your browser helper 43 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY pran PS ES Tel 39 02 39449519 Fax 39 02 700403170 ue i http www ipses com e mail info ipses com IM 1 5 j N core gipctr nics scloniific electronics l Te P LOS es TRAP EVENTS The SNMP server implemented on WEB IO board can generate two separate Trap events both of them associated to a change of inputs status Each event can be configured independently The minimum gap between two trap events is 10 seconds The Traps generated a
68. on of paragraph Power vr pga si tua dti d 01 02 0002 Updated RTCLOG module description paragraph MM A November 2010 Added paragraph Ethernet Module Added paragraph I O Management through http Updated telnet Server paragraph Added description for storing trap parameters in the SNMP Server paragraph Updated section Other I O cards available 01 03 0000 Added Remote Control Service paragraph Added Rivolta A December 2010 SMTP client and Remote Control description in http Server paragraph Updated telnet Server paragraph IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 Fax 39 02 700403170 iss jii ipses com e mail info ipses com roc J ust PSES ientific electronics 01 04 0000 Added P rl ya Function in Server http paragraph Rivolta A April 2011 and updated I O P rl ya through http gt IPSES scieniiic elec scientific electronics he f he P LOS ec ss paragraph 01 04 1000 Added description of Log memory reading service Riek A June 2011 through http page in http Server paragraph 01 05 0000 New template Introducing WEB IO 30 Extension Bottaccioli M January 2013 of Bootloader session in Htip server Trap working in Trap events Second telephone number 01 06 0000 Update PLC function in Http server and Telnet Rivolta A August 2014 server paragraphs IPSES S r l
69. or Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax 39 02 700403170 T gt http www ipses com e mail info ipses com scie nac electionici 090 1 5 j N e scientific electronics lp PI EXAMPLE OF USAGE The follow example shows how you can connect WEB IO for managing an external load with line supply Picture 4 shows how to connect WEB IO card with an external supply load Lh Su Load Phase 1 m Fe m li i Load j Load PhasezZ Load Phase 3 iii Load Load Phase 4 E Lord Load Phase 5 n Load Load Phase Load 4 B a f a IN 1 2 3 4 5 ao nodo hs B MM SE iba ia in hi B bt CD ii 3 E E E i oo Load Phase 7 z Logd Load Phase 5 ET ha E D STABILIZED POWER SUPPLY Fhase Heutral SW Line 230 V 1H10V Picture 4 external load with line supply management 13 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY te PS ES Tel 39 02 39449519 Fax 39 02 700403170 4 TT http www ipses com e mail info ipses com scientific electronics 49 1 5 j N cientilic electronics i f Te P LOS es RTCLOG MODULE DESCRIPTION The RTCLOG external module shown in Picture 5 is equipped with a log memory a Real Time Clock component and a Li lon rechargeable battery which allows to update the timetable when the module is not powered on The battery rechar
70. ovider where you connect your board For more information contact your network provider It is possible to restore factory parameters following this procedure listed below disconnect power supply from the board insert jumper J1 see Picture 1 connect power supply to the board If the procedure is successfully completed D2 and D3 LEDs will flash alternatively for about 3 seconds At this point it will be possible to remove jumper J1 form the board If TCP IP parameters of the network are not compatible with default board parameters or if the IP address is already assigned to another device you can reconfigure them choosing between the following two procedures IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 sahai elec B pet ipses com e mail info ipses com 1O 1 5 j N scientific electronics l b P IOS 2L ess Manual configuration procedure connect the board locally and directly to a PC equipped with a network card without connect it to any network verify that in the Property items under Local Network Connection Status LAN window located in Control Panel Network Connection Properties path the IP address of your PC is 192 168 0 1 and their Subnet Mask is 255 255 255 0 Otherwise set these values in their respective fields power on the board and access to http service typing in the URL browser the current board address by default
71. quisition Mode Read Input Advanced Commands Chip Temperature Firmware Version E P address 01 02 0000 l 192 168 0 16 Last Command Sent Read Output Port Picture 24a Main windows of the demo software The field Last Command Sent surrounded in orange in Picture 24a shows the last executed operation The selectors in the upper part directly manage the sixteen outputs in real time while the Read Output button update the software output LEDs exactly as in the card the software colour red is the same of the card Both logic inputs and outputs status can be achieved in two ways thanks to the selectors ring menu Surrounded in blue in Picture 24a the manual mode performs an asynchronous acquisition when you push respectively the Read Input button or Read Output button while the automatic mode performs a continuous polling of the inputs and or outputs status The polling rate is customizable by the Polling Time controls showed in Picture 24b these fields accept values between 1 5s and 10s with a step of 0 5s In both cases the software LEDs are updated at each acquisition the one referred to the inputs status are green while the ones referred to the outputs status are red OUTO OUT OUT2 OUT3 OUT4 OUTS OUTS OUT OUTS OUTS OUT10 OUT11 OUT12 OUTI3 OUT14 OUTIS v 9 9 9 Oo Oo 6 9 9 9 9 l Acquisition Mode Polling Time s x 45 Disable all PLC INO INI IN2 IN3 INA INS ING IN IN8 INS INIO INT
72. rd will remain in bootloader mode until the installation of a new firmware or the clicking on Exit button will be done The board will not work until the restoration of the normal mode If none of the two processes listed above will be executed i e the page will be closed using the x button on the right upper corner of the window it will be IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 Fax 39 02 700403170 http www ipses com e mail info ipses com 49 1 5 j N DIPSES core echoed scientific electronics es i b Q5 lt ESIPSES necessary opening the firmware upgrade page once again by the relevant IP address proceeding with the installation of a valid firmware or exit the process in the proper way JEIETES LEST X Google e Ml Ervin ta cerca gh ee E Condes Eh O dewa Pe Centelie bg Tree H ir Omn x gt AA beetles a o E mA Pepe Gos bue Appliczatrce Image Upload Retum to Application without boodoading file Las Picture 17 Firmware upgrade page The Browse button allows to select the bin file with the new firmware and the Upload button starts the installation process If the upgrade is completed successfully the board will automatically return to Operative mode and you will be redirect to index page To exit the Bootloader mode with no upgrade click the Exit button WEB IO Application Control provided by IPSES S
73. re LED surrounded in blue in Picture 25 is off and the DISABLED message appears The Set PLC button allows to store the configuration settings while the Cancel button closes the pop up window without saving them The square LED surrounded in red in Picture 24a shows the status of the Timeout function If it is disabled the LED is off and the TIMEOUT DISABLED message appears Three buttons on the right surrounded in green in Picture 24a allow to open three windows the first one for the outputs Advanced Output the second one for the inputs Advanced Input and the last one for the read and write commands in the non volatile memory Advanced Commands The Advanced Output window see Picture 26 allows the typical operations you can perform on the outputs of the device IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY van SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 i PALS echoed http www ipses com e mail info ipses com 090 1 5 j N Bop PO mamma Select Port Output Port 1 14949 9 4 9 Guo Select Port a PETIT Output Port 1 pM 901 DER 4040909000090 Get Output Port Select Port Pin to Set Output Port 0 Pin3 Select Port Pinto Get Pin Value Output Port1 APG Get Output Pin o 000000000000000 Read Stat Up Status 149 44449 4449 9 9 Set Start Up Status eo0900900000909092 0090029 Set output configuration far timeout event a ON adel IE Ed Tn
74. re compliant to v2c protocol specification and the information is stored in a sequence of two 16 bit format varbinds the first one encodes the input status In0 In15 the second one encodes the output status Out0 Out15 The parameters to configure for each event are trapEnable 0 1 respectively to disable enable the event notification trapReceiverlPAdrress IP address of the receiver machine i e the IP address of your PC trapCommunity a valid community name to receive the event notification By default the parameters of the Trap events are reset at every rebooting to avoid this condition set the save option variable in the setup path before configuring the parameters values If the save option variable is deactivated at the startup the parameters are reset To see in your mib browser the list of the generated events is necessary to open the Trap Receiver window with the Tools gt Trap Receiver command IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY x wd PSES Tel 39 02 39449519 Fax 39 02 700403170 SA 2 scientific echoed B pet ipses com e mail info ipses com 1O 1 5 j N scientific electronics ER P IOS 2 eus PROBLEMS RESOLUTION Below verification procedure steps to investigate board malfunctions are listed If the problem is not resolved contact the technical support of IPSES S r l sending the Engineering Problem Report included in this manual or downloadable
75. rnet Modalit protetta attivata fa y 100 v Picture 8 Timeout parameters configuration page Timeout Configuration page shown in Picture 8 allows to read and to set the parameters of the Timeout function Saved Status section display the status of the outputs if the Timeout field time elapses with no commands or requests received by the board Clicking on LEDs of Set Status section it is possible to set new outputs configuration while Timeout field allows to select the new timeout time among the following items No timeout 5sec 10sec 30sec 1min 5min 710min 30min Thour No timeout item disables the Timeout function on the board The Save Timeout Setting button stores the new settings on the memory of the board If the freezing function for http page commands is enabled the button is disabled The Timeout function has priority over PLC function described next When the Timeout function occurs the outputs will be sets as configured and remain in this status while any active PLC logic will be temporarily disabled until the board will not receive a new command or request 23 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY m PS ES Tel 39 02 39449519 Fax 39 02 700403170 gt http www ipses com e mail info ipses com 2D 1 5 j N acierta elec hordas WEB IO USER MANUAL AJ P S ES scientie electronics mnm Ae 7 oL Entra Ol X Google
76. rtup Configuration Timeout Configuration PLC Configuration WEB IO Control Panel Security Settings The security settings page allows to active or deactive independently the I O command i elements on the http pages or from the URL commands line of the Web server for WEB IO i board 2011000 i To change the settings insert the valid password quem Freeze http page commands Freeze URL line commands SNMP Community Configuration I O Label Configuration E mail Configuration Save Securitv Settings Remote Control Configuration TCP IP Configuration Securitv Settings Resume Bootloader Mode Info Copyright 2009 11 IPSES S r l www ipses com Internet Modalit protetta attivata fa y 1006 Picture 15 Security settings configuration page The Security Settings configuration page shown in Picture 15 allows to set the security levels only for functions implemented on the http server Its purpose is to inhibit the control of the board from unauthorized accesses There are 3 security levels Level 0 security option is not enabled Level 1 security on http pages Level 2 security on URL commands and automatically on http pages The security Level 0 allows to control the I O status and functionality of the board from anyone who enters the http pages or who knows the URL commands described in this manual IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY
77. sost omn T7 S Tena Sata Picture 26 Advanced Output window The output commands are listed below 19 Activation of each output for both ports Reset of the outputs all outputs are switched off Reading of the status of each output for each port Command and reading of a single output Reading of the start up configuration Setting of the start up configuration Reading of the Timeout function configuration outputs status and timeout time Settings of the Timeout function configuration outputs status and timeout time IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 Fax 39 02 700403170 ki jew ipses com e mail info ipses com PE y IPS ES cientilic electronics 2 gt PSES ichensEc Hechorics scientie electronics he l4 b Oo weou GIPS Advanced Input window see Picture 27 allows the typical operations you can performed on the inputs of the device The input commands are listed below e Reading of the status of each input for each port e Reading of the status of a single input Select Input Pin Statue Pin a Select Input Port Input Port 1 Status Port Bum 9999099099 Picture 27 Advanced Input window The Advanced Commands window see Picture 28 displays all TCP IP and firmware configuration parameters of the current board and allows to change the te net password The new telnet password must be inserted in the New Password field and replie
78. stems Each input and output status can be read by a WEB browser or a telnet client at any moment besides the status of digital inputs and outputs it is shown directly on the board thanks to LEDs fixed on 61 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY Tel 39 02 39449519 Fax 39 02 700403170 http www ipses com e mail info ipses com QA IPSES core eechonmct gt A e Oss scientific electronics N8 USB Input Card with 8 inputs and USB interface 9999999999 IN8 is a low size auto powered control unit equipped with USB interface IN8 can check eight galvanic isolated inputs on each input it is possible to apply voltages regardless form the USB ground with a maximum voltage of 30V Easy to use thanks to the driver provided with and to the LabVIEW library available on demand IN8 also reduce installation costs The board low size to be easily integrated in several systems Besides IN8 has its inputs galvanically isolated to protect from electromagnetic disturbances and ground loops improving its reliability and quality IN8 is the right answer to the need to acquire digital signals from a PC in an industrial environment LabVIEW Library for I O cards Ji i A complete library for LabVIEW giving the feasibility of I O devices remote control is available on request The Library allows to implement a LabVIEW application without knowing the details of the communication protocol
79. ters to enable and to process the automatic alert e mail sending based on an input status change The SMTP Server parameters section allows to configure the SMTP server parameters through which the mail is sent SMTP Server mail server address to use a mail server outbound your local network it is necessary to set a valid DNS address in TCP IP Configuration page Port is the access port of the server typically port 25 User Name is the authentication username to access the mail server Password is the authentication password to access the mail server The e mail client uses extended protocol Note not all the SMTP servers need an authentication access For further information contact your network administrator or the SMTP server operator The Enable Sending Mail field allows to enable or disable the mail sending when almost one input status change occurs The Mail header parameters section allows to set up to 5 different recipient addresses and the Object field for the e mail Each recipient address formatted as name domain com can be maximum 26 characters length while the Mail Subject field can be maximum 30 characters length The Save Configuration button allows to store the fields and the option selected If the freezing function for http page commands is enabled the button save configuration is disabled 27 IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY PS ES Tel 39 02 39449519 Fax
80. ts status of the Board A will be replied on the outputs of the Board B and in the same way the inputs status of the Board B will be replied on the outputs of the Board A On each card is not possible to manually set the outputs status until the service is active The service parameter configuration is described in the following http Server paragraph IPSES S r l Via Suor Lazzarotto 10 20020 Cesate MI ITALY SIPS ES Tel 39 02 39449519 Fax 39 02 700403170 L T B pet ipses com e mail info ipses com 1O 1 5 j N i enti echoed cientilic electronics dp b Oo ooo 35 PSES http SERVER The http server implemented on the board allows to manage up to 3 simultaneous sessions To access the server open a web browser and type the board IP address http 192 168 0 16 in the URL field you will be redirect to the main page index htm as shown in Picture 6 The implemented server was tested and was resulted fully compliant with the following browser Microsoft Internet Explorer 9 0 8112 16421 Mozilla Firefox 4 0 1 Google Chrome 11 0 696 77 Apple Safari 5 0 5 7533 21 1 All the web pages fulfill the W3C standard To avoid undesired accesses to control function of the board we have developed a multilevel security function its description is demanded later in this paragraph x Google J Effettua la ricerca 7 de em Condividi Ei Ap Controllo 3 Traduci S Compilazione autom gt
81. ure 18 lists the main information concerning firmware version and http page version running on the board O MANAGEMENT THROUGH http The WEB IO board can be interfaced to embedded system where it may be useful to command or to read the I O status through http protocol without performing a parsing of the previous described web pages The I O reading can be performed by edit in the URL the following address http current ip file where current ip is the board address i e 192 168 0 16 and file is one among the following ones getdo cgi read the digital output status in hexadecimal format MSB is Out15 and LSB is Out0 getdi cgi read the digital input status in hexadecimal format MSB is In15 and LSB is InO le http 192 168 0 16 ab since cgi i Preferiti 35 Els Siti suggeriti v 8 Raccolta Web Slice v vy Preferiti e Uem ig Siti suggeriti Raccolta Web Slice v http 192 168 0 16 getdo cgi http 192 168 0 16 getdi cgi J 3147 0546 To set a digital output edit in the URL the following address http current ip digbutton cgi dbtn x where x is referred to the digital output desired 0 15 This command acts on the selected output by performing a change of its current status it does not allows to select the logical level high or low but only to perform a toggle unless the output is not tied to a logical level by the PLC function enable If the security option Freeze URL line commands is enabl
82. zione autom gt Ap 7 J Entra gt oi Preferiti_ dig E Siti suggeriti v B Raccolta Web Slice H mn m 7 7 WEB IO Application Control provided by IPSES S Fio El Cl dA y Pagina Sicurezza Strumenti YY EPSES Scientific WEB IO Control Panel E Electronic E mail Configuration Panel Startup Configuration Serial number 2011000 Timeout Firmware version v01 05 0000 Configuration L OE mot E mail Configuration Panel SNMP Community Configuration i SMTP Server parameters Configure the mail server settings your SMPT i Server mav not require a user name or password I O Label Configuration SMTP Server out domain com Port 25 m E mail gt i username domain com Configuration e Remote Control y bi E Configuration Enable Sending Mail TCP IP Configuration Mail header parameters Configure the mail header settings it is possible to E insert up to 5 destination address max 30 chars for each one and configure AO Sa the Subject field Resume i Bootloader Mode Address 1 userl 2domain com Address 2 user2 domain com Address 3 user3 domain2 com Address 4 Address 5 Mail Subject mail test object Save Configuration Internet Modalita protetta attivata fa y 100 y Picture 12 E mail parameters configuration page SMTP client The E mail Configuration Panel shown in Picture 12 allows to set the parame