Release Notes for V2.5.1

image

Contents

1. For V2 3 0 Modified by MGT 12 November 2007 added ALLOW_CLEARING_CRITICAL_ALARM TRUE CARRIER ACB CARRIER_OPTIONS NEBS CARRIER_OPTIONS CM_INT_UP 5 CM_INT_DOWN 5 CARRIER_OPTIONS IN_EX SWITCHOFF 0 FRU_IN_ADM1026 0 CARRIER_OPTIONS NEBS IN_EX SWITCHOFF 0 CM_INT_UP 30 CM_INT_DOWN 10 MAX _ATCA_FANLEVEL 9 MAX _ATCA_TEMP 30 COOLING _ FAN INCREASE _TIMEOU 60 COOLING_FAN_ DECREASE TIMEOUT 60 FAN_LEVEL_STEP_UP 2 FAN_LEVEL_ STEP DOWN 1 NORMAL STABLE TIME 1800 INITIAL FAN _ LEVEL 8 MIN_FAN_LEVEL 3 SWITCHOVER_ON_HANDLE OPEN TRUE SWITCHOVER_TIMEOUT_ON_BROKEN_LINK 1 ALLOW_CLEARING_ CRITICAL ALARM TRUE cat shelfman conf ACB III Eth etc shelfman conf ACB III Modified by MGT 25 April 2006 Modified by MGT 21 June 2006 added NORMAL STABLE TIME parameter Modified by MGI rT 4 August 2006 added FRU_IN_ADM1026 0 INITIAL _SLOW_LINK_DELAY 120 Modified by MGT 15 August 2006 modified for V2 3 0 Modified by MGT 12 November 2007 added ALLOW_CLEARING_CRITICAL_ALARM FRU_IN_ADM1026 0 CM_INT_UP 30 CM_INT_DOWN 10 TRUE CARRIER ACB CARRIER_OPTIONS NEBS CARRIER_OPTIONS CM_INT_UP 5 CM_INT_DOWN 5 CARRIER_OPTIONS IN_EX_SWITCHOFF 0 CARRIER_OPTIONS
2. INI cat shelfman conf SMC1 etc shelfman conf SMC1 Modified by MGT 30 January 2006 Modified by MGT 9 August 2006 modified for V2 3 0 Release Note Schroff Firmware part number 63998 04664 22 31 January 22 2008 Schroff AivanceaTCA Modified by MGT 12 November 2007 added ALLOW_CLEARING_CRITICAL_ALARM TRUE CARRIER APW SWITCHOVER_ON_HANDLE_OPEN TRUE SWITCHOVER_TIMEOUT_ON_BROKEN_LINK 1 ALLOW_CLEARING_CRITICAL_ALARM TRUE Release Note Schroff Firmware part number 63998 04664 23 31 January 22 2008 Schroff AivanceaTCA New and Changed Features and Bug Fixes for Release 2 5 1 and previous Firmware releases 2 5 1 New and changed features 1 Enabled FRU data storage on the ACB IV shelf managers 2 Enabled ALLOW_CLEARING_CRITICAL_ALARM in the shelfman conf files so that the Critical Alarm condition can be cleared with the shelf manager console command clia alarm clear Known Issues for the Zephyr and Ventus Chassis 1 The DSAP alarm board will not be exposed as a FRU Implication DSAP functionality will not be operational Workaround There are no workarounds for this version 2 The ISAP Telco Alarms can be set but NOT cleared by the shelf manager using a clia alarm ____ command Implication The ISAP will not respond to commands to clear or remove Alarm LEDs Workaround There are no wo
3. Release Note Schroff Firmware part number 63998 04664 14 31 January 22 2008 Schroff Aivancea TGA Hit any key to stop autoboot 0 Booting image at be080000 Image Name Created Image Type Starting e e e e e e e e e e e e e e e e e e e e e e e Data Size Load Address Entry Point Verifying Checksum Uncompressing Kernel Image OK Loading Ramdisk Image at be440000 63998 Image Name Created Image Type Data Looking e e e e e e e lt gt 11 44 11 407 testes tc re tc re tc re tc re tc re ic res tc re tc re te re te res tc re tc re Ee rCs tc re tc re tc readhwaddr Board tc netconfig tc netconfig tc netconfig tc netconfig tc netconfig tc netconfig tc re Ee res EG re tc re Ee res tc re EC Tre Size Kern oun oun oun oun oun Chec oun Star oun Load Address Entry Point el Le 63998 04664 kernel Linux 2 4 26 2008 01 21 15 36 19 UTCC MIPS Linux Kernel Image gzip compressed 855848 Bytes 835 8 kB 80100000 802c6040 OK 04664 RFS 2008 01 21 15 36 19 UTC MIPS Linux RAMDisk Image gzip compressed 3508765 Bytes 3 3 MB 00000000 00000000 Verifying Checksum d proc OK ting filesystems ted dev pts ted dev mtdblock0O to var ted dev mtdblock10 to var upgrade king the reliable upgrade watchdog t
4. For ACB IV type shelf managers see table at the top of this document for identification the following commands have to be entered Download of FRU data to the Shelf Manager in 0x10 sh fru_update 10 0 lt Shelf Manager FRU file name gt Download of FRU data to the Shelf Manager in 0x12 sh fru_update 12 0 lt Shelf Manager FRU file name gt Step 4 Reboot the Shelf Manager reboot Release Note Schroff Firmware part number 63998 04664 19 31 January 22 2008 Schrof Ff Advance TGA Firmware part number 63998 04664 configuration file The configuration file etc shelfman conf contains all PPS default configuration variables for the Shelf Manager Variables that have been modified for Firmware version 63998 04664 are stored in the additional configuration files etc shelfman conf ACB II etc shelfman conf ACB III Eth etc shelfman conf ACB III USB etc shelfman conf ACB IV etc shelfman conf ACB ELSOL and etc shelfman conf ACB SMC1 The content of the custom specific configuration files is listed below cat shelfman conf ACB II etc shelfman conf ACB II Modified by MGI Modified by MGI Modified by MGI 31 January 2006 rT 21 June 2006 a T 4 August 2006 dded NORMAL _STABLE_TIME parameter added FRU_IN_ADM1026 1 IN ITIAL SLOW_LINK_DELAY 120 Modified by MGT 15 August 2006 modified
5. 7 The clia fru v command could display the Current Power Allocation parameter incorrectly in some cases with the fractional part of the allocation amount truncated 8 The clia fru command didn t show a FRU in M1 state in some cases 9 The Shelf Manager didn t check the MAX_SESSIONS configuration parameter for exceeding the architectural limit 10 An incorrect error message was shown in the command clia frucontrol in some cases 11 Setting of the SNMP variables sensor negative threshold hysteresis and sensor positive threshold hysteresis was done incorrectly 12 The command clia setfanlevel all could cause a fault in the clia utility in the case of incorrect parameters 13 The redundancy of the state of the LEDs on local FRUs represented by the Shelf Manager was not properly supported that could cause the command Get FRU LED State to report incorrect results after a switchover 14 The common handlers for the Get Fan Speed Properties Get Fan Level and Set Fan Level commands when targeting an ADM1026 managed fan tray that is represented by the Shelf Manager have been changed to confirm that the target fan tray is present before they take the requested action 15 Control C could not be used to kill the Shelf Manager application when it was invoked synchronously Release Note Schroff Firmware part number 63998 04664 26 31 January 22 2008 Schrof Ff AivanceaTCA 2 4 7 New and changed features
6. 12 The SNMP MIB file PPS_SENTRY MIB is now stored on the ShMM in the directory etc snmp and is available via the Shelf Manager s Web interface 13 Support has been added for software emulation of the ShMC site dependent cross connect type on shelves with the ShMC site independent cross connect type and vice versa Please see the ShMC cross connects specification PICMG ECN 3 0 2 0 001 for details on these two types of cross connects 14 Customer specific a Fixed fan tacho mapping for 1slot chassis b Implemented request for FT and PEM green LED behavior GREEN LED is OFF whenRED is ON c Disabled automatic telco alarm 15 Support added for chassis without fan trays Bug fixes 1 The LED state on local FRUs the Shelf Manager was sometimes shown incorrectly after switchover 2 When extracting the active Shelf Manager an M1 gt M0 Hot Swap event was not always logged for it 3 SDRs for the local FRUs in state MO were incorrectly present in the Shelf Manager Device SDRs 4 When an IPM controller came out of the Communication Lost state the old Hot Swap sensor number was used in the simulated M7 gt M2 Hot Swap event 5 If the active Shelf Manager crashed ata particular time during the initial startup the backup Shelf Manager could hang waiting for a response on the redundancy connection from the active 6 The Lamp Test could last longer than expected for LEDs managed by a physical IPM controller of the Shelf Manager
7. Gateway OEM record Shelf Manager IP Connection Netmask OEM record Shelf Manager IP Connection Delay Time OEM Record Power Management Save all rows Order OEM Record Power Management Save all rows Min Voltage OEM Record Power Management Save all rows Max Current OEM Record Power Management Save all rows Power OEM Record Power Management Save all rows Consumption Internal Use Area Complete FRU ID file upgrade The syntax is sh lt path gt fru_update lt IPMC gt lt FRU ID gt lt path gt lt filename gt lt options gt The table below lists valid values for lt IPMC gt and lt FRU ID gt Release Note Schroff Firmware part number 63998 04664 9 31 January 22 2008 Schroff AivanceaTCA lt IPMC gt lt FRU ID gt Description 10 0 Shelf Manager 1 20 1 Shelf SEEPROM 1 20 2 Shelf SEEPROM 2 20 254 Both Shelf SEEPROMs 20 3 Fan Tray 0 20 4 Fan Tray 1 20 5 Fan Tray 2 20 6 PEM 0 20 7 PEM 1 20 8 SAP lt path gt Location of the FRU files normally var nvdata lt filename gt Name of the FRU file Example 11596032BABIN bin 11596032 Product name BA Revision of the FRU data file BIN Identification for a FRU data file bin Format of FRU data file lt options gt p The power management section will not be saved and restored Examples sh var nvdata fru_update 20 254 var nvdata 11596101ABBIN bin Writes Chassis FRU data of t
8. 1 Monterey Linux ShM M 500R The IPMB driver was modified to improve fault detection when the ShMM 12C buffers are bypassed on physical star IPMB 0 implementations In addition to the previous modifications now potential collisions on IPMB during reattachment are handled correctly 2 When sending a Platform Event Trap the Shelf Manager now verifies that the corresponding network adapter is physically connected to the network and returns failure if this is not the case This is done to improve the delivery reliability for unacknowledged Platform Event Traps 3 The IPM controller firmware revision description produced by the CLI ipme v command now includes a three part representation of the revision number x y z in addition to the two part representation x yz since the three part convention is used in some contexts Bug fixes 1 The CLI sometimes incorrectly displayed the message No IPM FRUs found together with other valid error messages 2 The IPMB status changed bits could be incorrectly shown in the debug log in the case of an IPMB error 2 4 New and changed features 1 Support has been added for ShMM carriers that implement physical star IPMB 0 in such a way that I C buffers on the ShMM are bypassed This feature in the Shelf Manager relies on support in Monterey Linux The changes in the Shelf Manager are carrier specific On some carriers with this support this mode of operation is unconditional on
9. 21593250AABIN bin Shelf Manager 21593251AABIN bin Shelf Manager 23098163AABIN bin Various FRUs Fan Tray FRU file 21592048AABIN bin Fan Tray FRU file 21593190AABIN bin Fan Tray FRU file 21593372AABIN bin SAP FRU file 21594110ABBIN bin SAP FRU file 23098175BBBIB bin PEM FRU file 21596033ABBIN bin PEM FRU file 21596033ABBIN bin PEM FRU file 21596033ABBIN bin SAP FRU file 23098167CABIN bin Release Note Schroff Firmware part number 63998 04664 5 31 January 22 2008 Schroff AivanceaTCA Upgrading the Shelf Manager to Release 2 5 1 There are two ways of upgrading the Shelf Manager firmware You can use the TFTP Upgrade Procedure which is started from the U Boot environment of the Shelf Manager and retrieves the files from a TFTP server on your network You can also use the Reliable Upgrade Procedure This procedure will copy the new firmware flash images from a FTP server on your network to RAM on the ShMM 500 and then copy the images to flash memory We strongly recommend that you use the Reliable Upgrade Procedure instead of the TFTP Upgrade Procedure because it will leave the shelf manager in operating condition if the firmware upgrade fails TFTP Upgrade Procedure An overview of the procedure is as follows Download the 63998 04664 rfs and 63998 04664 kernel images and place them on your network reachable TFTP server The 63998 04664 rfs image includes the new 2 5 1 u boot bin sentry shmm500
10. 230 Logged on TYPE I 200 Type set to I PASV 227 Entering Passive Mode 192 168 0 7 6 201 RETR 63998 04664 shmm500 rfs 150 Connection accepted 226 Transfer OK QUIT 221 Goodbye rupgrade_tool invoking scripts step4v u 63998 04664 u boot bin k 63998 04664 shmm500 kernel r 63998 04664 shmm500 rfs proto ftp 192 168 0 7 ftp f tppw hook erase rupgrade_tool copying 63998 04664 u boot bin from tmp to dev mtdchar8 using cp protocol rupgrade_tool copying 63998 04664 shmm500 kernel from tmp to dev mtdchar7 usi ng cp protocol rupgrade_tool copying 63998 04664 shmm500 rfs from tmp to dev mtdchar9 using op protocol rupgrade_tool invoking scripts step4h erase etc upgrade step4hshm Stopping Shelf Manager Done etc upgrade step4hshm Cleaning new var partition Done etc upgrade step4hshm Cleaning new etc partition Done etc upgrade step4hshm Leaving var and etc empty except for ssh keys from et c ssh Done etc upgrade step4hshm Upgrade completed rupgrade_tool image s copy OK rupgrade_tool watchdog started rupgrade_tool selected provisional flash rupgrade_tool reboot Restarting system U Boot 1 1 4 Nov 26 2007 09 40 59 CPU Aul550 324 MHz id 0x02 rev 0x00 Board ShMM 500 S N 08005538 DRAM 128 MB Flash 64 MB Ins serial Out serial Erri serial ADM1060 configuration version 1 5 et Au1x00 ETHERNET
11. bin SAP FRU file 21596134AABIN bin 11596 103 Shelf FRU file 596103ACBIN bin Fan Tray FRU file 21596132ABBIN bin PEM FRU file 21593312ABBIN bin SAP FRU file 21596134AABIN bin 11596 300 Shelf FRU file 596300AABIN bin Fan Tray FRU file 21596198AABIN bin PEM FRU file 21594340BABIN bin SAP FRU file 21594159CABIN bin 11596 301 Shelf FRU file 11596301AABIN bin Fan Tray FRU file 21596198AABIN bin PEM FRU file 21594340BABIN bin SAP FRU file 21594159CABIN bin 11596 302 Shelf FRU file 11596302ABBIN bin Fan Tray FRU file 21596198AABIN bin PEM FRU file 21594340BABIN bin SAP FRU file 21594159CABIN bin 11596 303 Shelf FRU file 11596303ABBIN bin Fan Tray FRU file 21596198AABIN bin PEM FRU file 21594340BABIN bin SAP FRU file 21594159CABIN bin 11592 400 Shelf FRU file 11592400DBBIN bin Fan Tray FRU file 21593100CABIN bin PEM FRU file 21594340BABIN bin SAP FRU file 21594159CABIN bin 11592 401 Shelf FRU file 11592401CEBIN bin Fan Tray FRU file 21593100CABIN bin PEM FRU file 21594340BABIN bin SAP FRU file 21594159CABIN bin 11592 402 Shelf FRU file 11592402DABIN bin Fan Tray FRU file 21593100CABIN bin PEM FRU file 21594340BABIN bin SAP FRU file 21594159CABIN bin 11592 403 Shelf FRU file 11592403DABIN bin Fan Tray FRU file 21593100CABIN bin PEM FRU file 21594340BABIN bin SAP FRU file 21594159CABIN bin 11592 500 Shelf FRU file 11592500BABIN bin Fan Tray FRU file 21594357ACBIN bin PEM FRU file 21593312ABBIN bin SAP FRU file 21594346ABBIN bin 11592 501 Shelf
12. other carriers this mode is enabled by a carrier option 2 This release is based on updates of Monterey Linux that includes the following changes e ShMM 500R The dropbear SSH application no longer writes to wtmp fixing a problem where wtmp could grow on an unbounded basis ShMM 500R A memory leak was fixed in Net SNMP additional memory was allocated and not reclaimed each time NetSNMP could not send a packet to the network The shared library libnetsnmpagentso is affected ShMM 500R The busybox ifconfig function was modified to enable ifconfig ethO broadcast which allows automatically determining the broadcast address ShMM 500R The rupgrade_tool was augmented with a default image settings option so that the image file names can be omitted on the command line if the default names are to be used e ShMM 500R The Au1000 Ethernet driver which applies to the ShMM 500R s Au1550 as well was modified to accurately report the transmit byte count when ifconfig a Previously there was an error in the driver that caused the transmit byte count to be reported incorrectly In addition the packet reception processing in the Ethernet driver was optimized to minimize possible packet losses in NAPI mode Release Note Schroff Firmware part number 63998 04664 27 31 January 22 2008 Schrof Ff AivanceaTCA ShMM 500R The IPMB driver was modified to improve fault detection when the ShMM i buffers are
13. used to kill the Shelf Manager application when it was run synchronously 2 4 4 New and changed features 1 The debug levels are now separate for the system log and the console This allows different levels of verbosity to be specified for system log output and console output 2 The criteria to recognize FRUs that are potential sources of the Shelf FRU Information are now more Strict Now if the configuration parameter LOCAL_SHELF_FRU is set to TRUE no external FRU ID 1 can be selected as a Shelf FRU Information source and therefore potentially updated with the cached Shelf FRU Information 3 OpenHP Entity Location for SAP is incorrect The reason was incorrect entity ID for the SAP board on Schroff shelves Entity ID has been changed from 7 System board to F3 Alarm panel 4 Shelf manager must print the reason on the console for taking a graceful reset Debug levels for the system log and for the console have been separated so it is possible now to assign a less detailed debug level to the console to show only error messages 5 When fan or pem is pulled led status still shows up Fixed handlers for LED related ATCA commands to return a completion code when the target FRU is in MO 6 SAP User LED color reported incorrectly The reason was that the same LEDs on the same FRU in different types of Schroff shelves Sun and non Sun have different colors The code has been changed to report Sun LED colors if the SAP FRU Information cont
14. 2008 Schrof Ff AivanceaTCA ShMM 500R The busybox syslogd function was changed to respect the timezone TZ variable Without this fix the busybox getty and login functions would report only UTC time in the syslog ShMM 500R The following utilities have been added to the RFS image patch_fru_info fru_internal i2c_test and gpiomips ShMM 5OOR An update of the Pigeon Point SNMP MIB PPS SENTRY MIB txt has added SNMP access to several aspects of the overall Shelf Manager state specifically the RMCP Up Shelf FRU Found and Active State indicators that also appear in the output of clia shmstatus v Also descriptions of some variables that had been missing previously were added to the MIB file 2 Support for AMC carriers and AMCs is now enhanced in the Command Line Interface CLI Most CLI commands now accept the syntax amc lt N gt where a FRU Device ID is expected and translate the AMC number to its corresponding FRU Device ID Also the syntax pem lt N gt is now supported to designate PEMs 3 Support for the Pigeon Point Hardware Platform Definition Language HPDL has been added HPDL is a Pigeon Point defined language for describing ShMM carrier specific aspects of the Shelf Manager and is intended to allow the Shelf Manager to support new ShMM carriers and their corresponding shelf types without modifying the Shelf Manager source code The HPDL support in the 2 5 0 release is preliminary This feature is expected t
15. 4 15 31 January 22 2008 Current Boot I Image Name Created Image Type Data Size Load Address Entry Point Schroff Aivancea TGA 63998 04664 uboot bin 1 1 4 Mon Jan 21 15 36 19 2008 MIPS Linux Firmware uncompressed 183836 Bytes 179 53 kB 0 18 MB 0x9FCO0000 0x00000000 Current Kernel Image Name Created Image Type Data Size Load Address Entry Point Current RFS Image Name Created Image Type Data Size Load Address Entry Point 63998 04664 kernel Linux 2 4 26 Mon Jan 21 15 36 19 2008 MIPS Linux Kernel Image 855848 Bytes 0x80100000 0x802C6040 gzip compressed 835 79 kB 0 82 MB 63998 04664 RFS Mon Jan 21 15 36 19 2008 MIPS Linux RAMDisk Image gzip compressed Alternate Boot Image Name Created Image Type Data Size Load Address Entry Point 3508765 Bytes 3426 53 kB 3 35 MB 0x00000000 0x00000000 63998 04662 uboot bin 1 1 4 Mon Jan 7 17 08 54 2008 MIPS Linux Firmware uncompressed 183836 Bytes 179 53 kB 0 18 MB 0x9FCO0000 0x00000000 Alternate Linux Image Name Created Image Type Data Size Load Address Entry Point Alternate RFS Image Name Created Image Type Data Size Load Address Entry Point Pigeon Point Running on Pigeon Point Pigeon Point Copyright c reserved All rights Build date time Carrier ACB Carrier subtype STEP 3 the Backup Shelf Man
16. 4664 6 31 January 22 2008 Schrof f AivanceaTCA If any of these need changing do it as follows shmm500 setenv serverip 192 168 0 88 shmm500 saveenv Saving Environment to EEPROM shmm500 IMPORTANT As part of the upgrade process the ENV VAR settings will be restored to factory default Please make sure to take note on the ENV VAR settings so they can be restored at the end of the upgrade To print out the current settings type shmm500 printenv Step 5 If your SAMM 500 module has the net command defined you can use this to boot the upgrade kernel and rfs as follows shmm500 run net If it does not you can do this setenv bootargs bootargs root dev ram rw console ttyS0 115200 reliable_upgrade y tftp 80400000 sentry kernel tftp 81200000 sentry rfs bootm 80400000 81200000 The upgrade kernel and rfs will boot and automatically start the upgrade process This procedure may take several minutes Step 6 Upon successful upgrade reboot to U Boot and restore the RC2 environment variable shmm500 setenv rce2 etc rce achb4 shmm500 saveenv saveenv overview table at the beginning of this document A common problem that causes the Shelf i Please find the correct RC2 variable for your Shelf Manager type in the Shelf Manager Manager to misbehave is to set the rc2 U Boot Environment variable incorrectly Step 7 Boot the Shelf Manager and log in as root Ignore the password by pushing the Return key Enter the c
17. B bin PEM FRU file 21592133BBBIN bin SAP FRU file 23098167CABIN bin 11592 042 Shelf FRU file 592042BCBIN bin Fan Tray FRU file 21592048AABIN bin PEM FRU file 21592047AABIN bin SAP FRU file 23098167CABIN bin 11592 0027 Shelf FRU file 11592027BFBIN bin Fan Tray FRU file 21592048AABIN bin PEM FRU file 21592047AABIN bin SAP FRU file 23098167CABIN bin 11592 111 Shelf FRU file 592111BBBIN bin 11596 007 Shelf FRU file 596007ACBIN bin 11596 009 Shelf FRU file 596009ABBIN bin 11596 010 Shelf FRU file 596010ADBIN bin 11596 012 Shelf FRU file 596012ACBIN bin 11596 026 Shelf FRU file 596026AABIN bin 11596 040 Shelf FRU file 596040AABIN bin 11596 045 Shelf FRU file 596045AABIN bin SYS000517 Shelf FRU file SYS000517AABIN bin BPLO00763 Shelf FRU file BPLOO0763AABIN bin SYS000764 Shelf FRU file SYS000764BCBIN bin SYS000766 Shelf FRU file SYSO00766BIBIN bin SYSOOO0766FT Shelf FRU file SYSO00766FTACBIN bin SYS001916 Shelf FRU file SYS001916ABBIN bin SYS002927 Shelf FRU file SYS002927AEBIN bin BPL003011 Shelf FRU file BPL003011AABIN bin SYS003214 Shelf FRU file SYS003214AABIN bin SYS003862 Shelf FRU file SYSO03862AABIN bin SYS004060 Shelf FRU file SYSOO4060ACBIN bin SYS03214R Shelf FRU file SYS03214RACBIN bin SYS03761R Shelf FRU file SYS03761RAABIN bin VEN12ATCA014 Shelf FRU file VEN12ATCAO014AFBIN bin ZRSATC6TMDPEM2N Shelf FRU file ZRSATC6TMDPEM2NAGBIN bin Shelf manager FRU Shelf Manager 21594346ACBIN bin files Shelf Manager 21594347ACBIN bin Shelf Manager
18. FRU file 592501BABIN bin Fan Tray FRU file 21594357ACBIN bin PEM FRU file 21593312ABBIN bin SAP FRU file 21594346ABBIN bin 11592 502 Shelf FRU file 592502DABIN bin Fan Tray FRU file 21594357ACBIN bin PEM FRU file 21593312ABBIN bin SAP FRU file 21594346ABBIN bin 11592 503 Shelf FRU file 592503CABIN bin Fan Tray FRU file 21594357ACBIN bin PEM FRU file 21593312ABBIN bin SAP FRU file 21594346ABBIN bin 11596 006 Shelf FRU file 11596006ACBIN bin Fan Tray FRU file 21593100CABIN bin PEM FRU file 21596033ABBIN bin SAP FRU file 21594159CABIN bin 11596 025 Shelf FRU file 21596025AABIN bin Fan Tray FRU file 21596033ABBIN bin PEM FRU file 21594159CABIN bin SAP FRU file 21596025AABIN bin 11596 027 Shelf FRU file 11596027AABIN bin Fan Tray FRU file 21593100CABIN bin PEM FRU file 21594340BABIN bin Release Note Schroff Firmware part number 63998 04664 4 31 January 22 2008 Schroff AivanceaTCA SAP FRU file 21594159CABIN bin 11592 085 Shelf FRU file 592085BGBIN bin Fan Tray FRU file 21592122BBBIB bin PEM FRU file 21592133BBBIN bin SAP FRU file 23098167CABIN bin 11592 044 Shelf FRU file 592044CABIN bin Fan Tray FRU file 21592122BBBIB bin PEM FRU file 21592133BBBIN bin SAP FRU file 23098167CABIN bin 11592 043 Shelf FRU file 592043BDBIN bin Fan Tray FRU file 21592122BBBI
19. IMEOU 60 60 IN 60 Li ER uspo usb1 i cat shelfman conf ACB IV etc shelfman conf ACB IV Modified by MGT 25 April 2006 Modified by MGT 21 June 2006 added NORMA added FRU_IN_ADM1026 0 For V2 3 0 LLOW_ CLEARING CRITICAL ALARM CM_INT_DOWN 5 FRU_IN_ADM1026 0 IN_EX_SWITCHOFF 0 CM_INT_UP 30 CM_INT_DOWN 10 STABLE _TIME parameter Modified by MGT 4 August 2006 INITIAL SLOW_LINK_DELAY 120 added FRU_IN_ADM1026 1 For V2 3 0 LLOW_CLEARING CRITICAL ALARM FRU_IN_ADM1026 1 CM_INT_UP 30 CM_INT_DOWN 10 Modified by MGT 15 August 2006 modified Modified by MGT 12 November 2007 added Al TRUE CARRIER ACB CARRIER_OPTIONS NEBS CARRIER_OPTIONS CM_INT_UP 5 CM_INT_DOWN 5 CARRIER_OPTIONS IN_EX _SWITCHOFF 0 CARRIER_OPTIONS NEBS IN_EX_SWITCHOFF 0 MAX_ATCA_FANLEVEL 9 Release Note Schroff Firmware part number 63998 04664 21 31 January 22 2008 Schroff Aivancea TGA MAX_ATCA_TEMP 30 COOLING_FAN_INCREASE_TIMEOUT 60 COOLING_FAN_DECREASE_TIMEOUT 60 FAN_LEVEL_STEP_UP 2 FAN_LEVEL_STEP_DOWN 1 NORMAL _STABLE_TIME 1800 IPMB_LINK_ISOLATION_TIMEOUT 60 INITIAL_FAN_LEVEL 8 MIN_FAN_LEVEL 3 REDUNDANCY_NET_ADAPTER usb0 REDUNDANCY_NET_ADAPTER2 usbl1 RMCP_NET_ADAPTER2 ethl1 SWITCHOVER_ON_HANDLE_OPEN TRUE S
20. Monterey Linux This release in based on an update of Monterey Linux that has the following new features ShMM 500R The USB device driver has been fixed to properly handle errors that may occur during direct memory access operations Without this fix the USB connection between active and backup Shelf Managers might break unexpectedly and be restored only by a backup Shelf Manager reboot ShMM 500R The busybox syslogd function was changed to respect the timezone TZ variable Without this fix the busybox getty and login functions would report only UTC time in the syslog e ShMM 500R The utility wtmp has been removed from busybox because it could cause unbounded growth of the login log in RAM 2 Support has been added for software emulation of the ShMC site dependent cross connect type on shelves with the ShMC site independent cross connect type and vice versa Bug Fixes 1 The Lamp Test could last longer than expected for LEDs managed by a physical IPM controller of the Shelf Manager 2 The clia fru v command could display the Current Power Allocation parameter incorrectly in some cases with the fractional part of the allocation amount truncated Release Note Schroff Firmware part number 63998 04664 28 31 January 22 2008 Schrof Ff AivanceaTCA 3 Setting of the SNMP variables sensor negative threshold hysteresis sensor positive threshold hysteresis was done incorrectly 4 Control C could not be
21. NEBS IN_EX_SWITCHOFF 0 MAX_ATCA_FANLEVEL 9 MAX_ATCA_TEMP 30 COOLING_FAN_INCREASE_TIMEOU 60 COOLING_FAN_ DECREASE TIMEOUT 60 FAN_LEVEL_STEP_UP 2 Release Note Schroff Firmware part number 63998 04664 20 31 January 22 2008 FAN_LEVEL_STEP_DOWN 1 NORMAL STABLE TIME 1800 IPMB_LINK_ISOLATION_TIMEOUT INITIAL FAN_LEVEL 8 MIN_FAN_LEVE 3 SWITCHOVER_ON_HANDLE_OPEN TRUE SWITCHOVER_TIMEOUT_ON_BROKEN_LINK ALLOW_CLEARING_CRITICAL_ALARM TRUE 60 iy a cat shelfman conf ACB III USB etc shelfman conf ACB III Modified by MGT 25 April 2006 Modified by MGT 21 June 2006 added NORMA Schroff Aivancea TGA STABLE_TIME parameter Modified by MGT 4 August 2006 ITIAL SLOW_LINK_DELAY 120 Modified by MGT 15 August 2006 modified Modified by MGT 12 November 2007 added Al TRUE CARRIER CARRIER_OPTIONS CARRIER_OPTIONS CARRIER_OPTIONS CARRIER_OPTIONS MAX_ATCA_FANLEVEL MAX_ATCA_TEMP 30 COOLING_FAN_INCREASE __ COOLING_FAN_DECREASE FAN_LEVEL_ STEP_UP FAN_LEVEL _STEP_DOWN 1 NORMAL _STABLE_ TIME 1800 IPMB_LINK_TSOLATION_TIMEOUT INITIAL FAN LEVEL 8 MIN_FAN_LEVEL 3 REDUNDANCY_NET_ADAP REDUNDANCY_NET_ADAPTER2 RMCP_NET_ADAPTER2 ethi SWITCHOVER_ON_HANDLE_ OPEN TRUE SWITCHOVER_TIMEOUT_ON_BROKEN_LINK ALLOW_CLEARING CRITICAL ALARM TRUE IN ACB NEBS CM_INT_UP 5 IN_EX_SWITCHOFF 0 NEBS 9 IMEOU
22. Rebuilt netsnmp to support latest Shelf Manager interface ShMM 300 Rebuilt ucdsnmp to support latest Shelf Manager interface 2 Implemented a new Pigeon Point IPMI command Set Shelf FRU Configuration Record The command can be used to update a specific record of a specific type in the Shelf FRU Information The implementation of the command takes care of updating the record checksum appropriately 3 Added support initially for just one ShMM carrier type for a Network Element ID string that is stored in the Shelf FRU Info SEEPROM but outside the visible Shelf FRU Info records The new CLI command networkelementid is used to get and set the value of this string The variant of this command that sets the value is limited to running only in a Linux superuser context 4 The implementation of the CLI command help has been modified so that help text for a carrier specific command is not shown if the Shelf Manager is running on a carrier that does not support that command 5 Introduced the macro SET CARRIER SUBVERSION as a new required way to specify the carrier subversion Release Note Schroff Firmware part number 63998 04664 30 31 January 22 2008 Schrof Ff Advance TGA 6 Fixed PEM presence detection when shelf FRU has not been found yet Bug Fixes 1 The assertion deassertion masks and the discrete reading mask in the SDR for the CPLD State sensor were incorrect did not include all possible values 2 Link ext
23. Schroff need CA Release Notes Schroff firmware part number 63998 04664 Based on Pigeon Point Systems PPS firmware release 2 5 1 for ShMM 500 Release Date January 21 2008 Release History Release date Schroff FW P N PPS version December 14 2006 63998 04657 V2 3 2 April 26 2007 63998 04660 V2 4 2 January 18 2008 63998 04662 V2 5 1 January 21 2008 63998 04664 V2 5 1 Updated Introduction The firmware package 63998 04664 zip contains Firmware release 2 5 1 for the ShMM 500 The PPS RFS image has been modified by Schroff to adapt the firmware to the Schroff ATCA chassis The kernel image has not been modified and is identical to the PPS kernel image The Schroff part number for this firmware release is 63998 04664 Shelf manager versions The overview below shows the different versions of Schroff Shelf Manager carrier boards Pigeon Point Systems ShMM 500 Module installed Before proceeding with this firmware installation please make sure that your shelf manager is equipped with a SaMM 500 module The photo below shows the ShMM 300 and the ShMM 500 il Note This release note only applies to shelf manager carrier boards which have the TTT TTT FETETETE sreeeree belie yee ShMM 500 ShMM 300 Release Note Schroff Firmware part number 63998 04664 1 31 January 22 2008 Schroff need CA The table below shows the shelf manager versions please identify your shelf manager typ
24. WITCHOVER_TIMEOUT_ON_BROKEN_LINK 1 ALLOW_CLEARING_CRITICAL_ALARM TRUE cat shelfman conf ELSOL etc shelfman conf ACB ES Modified by MGT 25 April 2006 Modified by MGT 21 June 2006 added NORMAL_STABLE_TIME parameter t Modified by MGT 4 August 2006 added FRU_IN_ADM1026 1 INITIAL SLOW_LINK_DELAY 120 Modified by MGT 15 August 2006 modified for V2 3 0 Modified by MGT 27 September 2006 modified for V2 3 2 Modified by MGT 14 December 2006 modified for V2 4 0 Modified by MGT 12 March 2007 modified for V2 4 2 Modified by MGT 12 November 2007 added ALLOW_CLEARING_CRITICAL_ALARM TRUE CARRIER ELSOL CARRIER_OPTIONS NEBS CARRIER_OPTIONS CM_INT_UP 5 CM_INT_DOWN 5 CARRIER_OPTIONS IN_EX_SWITCHOFF 0 FRU_IN_ADM1026 1 ACB 1 CARRIER_OPTIONS NEBS IN_EX_SWITCHOFF 0 CM_INT_UP 30 CM_INT_DOWN 10 MAX_ATCA_FANLEVEL 9 MAX_ATCA_TEMP 30 COOLING_FAN_INCREASE_TIMEOUT 60 COOLING_FAN_DECREASE_TIMEOUT 60 FAN_LEVEL_STEP_UP FAN_LEVEL_STEP_DOWN ale NORMAL _STABLE_TIME 1800 IPMB_LINK_ISOLATION_TIMEOUT 60 INITIAL_FAN_LEVEL 3 MIN_FAN_LEVEL 1 REDUNDANCY_NET_ADAPTER usb0 REDUNDANCY_NET_ADAPTER2 usb1 RMCP_NET_ADAPTER2 ethl1 SWITCHOVER_ON_HANDLE_OPEN TRUE SWITCHOVER_TIMEOUT_ON_BROKEN_LINK 1 ALLOW_CLEARING_CRITICAL_ALARM TRUE
25. ager 63998 04662 kernel Linux 2 4 26 Mon Jan 7 17 08 53 2008 MIPS Linux Kernel Image 855848 Bytes 0x80100000 0x802C6040 gzip compressed 835 79 kB 0 82 MB 63998 04662 RFS Mon Jan 7 17 08 53 2008 MIPS Linux RAMDisk Image gzip compressed 3507042 Bytes 3424 85 kB 3 34 MB 0x00000000 0x00000000 Shelf Manager Command Line Interpreter with limited functionality Shelf Manager ver 2 5 1 is a trademark of Pigeon Point Systems 2002 2007 Pigeon Point Systems Jul 30 2007 16 44 14 4 subversion 0 Updating FRU data files Release Note Schroff Firmware part number 63998 04664 16 31 January 22 2008 Schroff AivanceaTCA Change to the var nvdata directory cd var nvdata Do not use the command clia frudataw to update the FRU ID files Note The only exception to this recommendation is for ACB IV shelf managers that do not contain FRU data This will be true for most ACB IV shelf managers that originally shipped with firmware V2 3 2 or earlier You can check for the presence of shelf manager FRU data with the commands clia frudata 10 0 and clia frudata 12 0 If you get a response like that shown below then you need to use the commands clia frudata 10 0 var nvdata lt Shelf Manager FRU file name gt and clia frudata 12 0 var nvdata lt Shelf Manager FRU file name gt to install FRU data into the shelf manger You will need to substitute lt Shelf Manager FRU file name gt
26. ains the custom parameter SUN 1 The attached SAP FRU Information file contains this custom parameter and can be used to updated SAP FRU Information for SAP FRUs on Sun shelves 7 ShMM writes midplane fru data into RTM FRU EEPROM if RTM Frudata is not correct Now the Shelf Manager does not consider an arbitrary FRU 1 as a potential source of Shelf FRU Information if the configuration parameter LOCAL SHELF _FRU l see generic release notes 8 ShMM prints error messages if it fails to read frudata Number of printed error messages has been reduced 9 fruinfo command doesn t check the frudata header to the content validity Check has been added 10 When a fan tray is deactivated it must be reactivated to force Hot Swap light off Fixed 11 clia command help messages uses addr for both IPMB and HW address Modified the help text so that hw addr is printed instead of addr for commands that expect hardware address Bug Fixes 1 When a local FRU was removed from the shelf the command Get LED State addressed to it was still successful and returned the cached LED state 2 Excessive error messages resulted from the command clia frudata when the destination FRU data was not available Release Note Schroff Firmware part number 63998 04664 29 31 January 22 2008 Schrof Ff AivanceaTCA 3 FRU Information was parsed by the command clia fruinfo even if there was an error in the FRU Information header 4 When a local FRU with a Ho
27. bypassed on physical star IPMB 0 implementations Previously an attempt to attach to the bus in this mode would always succeed even if there was a persistent failure on the bus The updated driver attempts to transmit a message to the OXEE address to verify the bus state as part of the attach operation which now returns success only if the transmission to OXEE was successful Bug fixes 1 The CLI command fru showed inconsistent information about FRUs in state M1 2 When the active Shelf Manager was extracted an M1 gt M0 Hot Swap event was not always logged for it 3 Entity IDs for certain shelf wide sensors e g the Air Filter presence sensor were assigned incorrectly 4 An incorrect change state cause was reported when subsidiary FRUs of the Shelf Manager were programmatically transitioned from state M1 to M2 and from state M4 to M5 5 An incorrect sequence of Hot Swap events was generated when the backup Shelf Manager was taken out of the Communication Lost state M7 6 The BMC watchdog timer commands were not rejected when directed to a physical controller of the Shelf Manager 7 Special settings for the fan tray power consumption made through the fan tray FRU Information were not propagated across the redundancy interface to the backup Shelf Manager 8 AMC link designators in an AMC Point to P oint Connectivity Record were incorrectly shown by the CLI command fruinfo 2 4 New and changed features 1 Updated release of
28. c to the serial interface of the Shelf Manager RJ45 connector SERIAL or ShMgr on the SAP Set the terminal or emulator to 115200 N 8 1 115200 baud no parity 8 bits per character 1 stop bit Login user is root with no password FRU ID files The Shelf Manager firmware images also contain FRU ID files for the Shelf Fan Trays PEMs SAP and the Shelf Manager Important Note This firmware release also contains updated chassis FRU data files These FRU data files are stored in the var nvdata directory of the SAMM 500 The installation procedure of the FRU data files is described below Please make sure to install these FRU data files after installing the new firmware image FRU ID files included in firmware version 63998 04664 Shelf P N FRU type FRU ID file name 11596 100 Shelf FRU file 11596100AABIN bin Fan Tray FRU file 21596132ABBIN bin PEM FRU file 21593312ABBIN bin SAP FRU file 21596134AABIN bin Release Note Schroff Firmware part number 63998 04664 3 31 January 22 2008 Schrof f AivanceaTCA 11596 101 Shelf FRU file 596101ABBIN bin Fan Tray FRU file 21596132ABBIN bin PEM FRU file 21593312ABBIN bin SAP FRU file 21596134AABIN bin 11596 102 Shelf FRU file 596102AABIN bin Fan Tray FRU file 21596132ABBIN bin PEM FRU file 21593312ABBIN
29. e You will need the corresponding RC2 variable later in the upgrade process Photo Type RC2 variable i ACB IV rc acb4 1 ACB IV installed in rc acb es ze an Electronic Solutions Zephyr or Ventus ATCA The part number of the ACB IV Shelf Manager is on chassis the label at the rear side of the Shelf Manager see photo below Radial IPMB version part number 21594 347 Bused IPMB version part number 21594 346 Part Number SHELFMANAGER 450500622 A POT Serial Number Rev ACB III rc acb3 The following Shelf Manager types originally shipped with ShMM 300 modules but might have been upgraded to ShMM 500 modules by the customer ACB III rc acb3e ACB II rc acb2 Release Note Schroff Firmware part number 63998 04664 2 31 January 22 2008 Schrof Ff AivancenTCA SMC 1 rc smc1 Preparation Firmware files Unzip the file sentry 63998 04664 zip This file contains the following Pre Built images TFTP Upgrade files 63998 04664 kernel Upgrade kernel image for TFTP upgrade 63998 04664 rfs Upgrade RFS image for TFTP upgrade Reliable Upgrade files 63998 04664 shmm500 kernel Upgrade kernel for reliable upgrade 63998 04664 shmm500 rfs Upgrade RFS for reliable upgrade 63998 04664 u boot bin Upgrade u boot for reliable upgrade Terminal Program Connect a serial console cable to a terminal or PC running a terminal emulator Hypercom Minicom Hyperterminal et
30. e later analyzed for clues about the cause of the failure with the dumplog utility via the option f 7 Forced switchovers from the backup Shelf Manager to handle the case of a frozen active ShMM CLI command switchover force are now supported No negotiations between the Shelf Managers happen in this case the backup Shelf Manager immediately takes control in hardware 8 Support for retrieving and setting fan levels in the SNMP interface has been added 9 When responding to the IPMI command Send Message the sequence number in the bridged response is now taken from the encapsulated command Previously it was taken from the Send Message wrapper command This change is considered to be more in line with the IPMI specification the old behavior can be restored by setting to FALSE the following configuration parameter INNER SEQUENCE NUMBER _IN SEND MSG RESPONSE 10 The window size of RMCP sequence numbers is now configurable via the configuration parameter SESSION SEQUENCE WINDOW with default being 128 instead of a fixed size of 8 This improves Shelf Manager resiliency against losses of packets in the network 11 Support for on ShMM event handling via PEF has been added When an event takes place a designated local executable or script running on the ShMM is invoked and passed the fields of the event message as parameters Release Note Schroff Firmware part number 63998 04664 25 31 January 22 2008 Schrof Ff AivanceaTCA
31. ension handling was done incorrectly for some cases in the E Keying algorithm of the Shelf Manager now links with different link extensions are considered different links 3 The first row of the following tables was not accessible via SNMP pef configuration event filter table pef configuration alert policy table 4 When a board that had lost communication with the Shelf Manager was replaced with a different board the simulated Hot Swap event M7 gt M0 for the first board might use an incorrect sensor number 5 An output message queue in the Shelf Manager could temporarily overflow if an RMCP client was subscribed for asynchronous event notifications and the session was abruptly terminated A prevention mechanism for this problem has been implemented 6 CLI did not show the highest nibble of the assertion deassertion masks and the discrete reading mask in the response to the command clia sensor 7 The Shelf Manager could crash if a response to the Get Device Id command sent during initial polling of the IPMCs in the shelf had an illegal length 8 The SNMP MIB definition of the lan configuration destination address 0 15 variables didn t match the actual read write constraints Release Note Schroff Firmware part number 63998 04664 31 31 January 22 2008
32. estores the variables in Table 1 without saving and restoring the power management data sh var nvdata fru_update 20 3 var nvdata 21596132ABBIN bin Writes Fan Tray FRU data into the FRU_data SEEPROM of the left Fan Tray Fan Tray 0 and restores the variables listed in Table 1 Complete update For a complete update of all FRU EEPROMs the following commands are necessary You can omit the path if you have cd ed to the directory containing either fru_update or the FRU Files or both e g cd var nvdata Release Note Schroff Firmware part number 63998 04664 18 31 January 22 2008 Schrof f AivanceaTCA sh fru_update 10 0 21596247AB BIN bin Commands for complete update Download of FRU data to shelf SEEPROM 1 sh fru_update 20 1 lt Chassis FRU file name gt Download of FRU data to shelf SEEPROM 2 sh fru_update 20 2 lt Chassis FRU file name gt Download of FRU data to Fan Tray 0 sh fru_update 20 3 lt Fan Tray FRU file name gt Download of FRU data to Fan Tray 1 sh fru_update 20 4 lt Fan Tray FRU file name gt Download of FRU data to Fan Tray 2 sh fru_update 20 5 lt Fan Tray FRU file name gt Download of FRU data to PEM A sh fru_update 20 6 lt PEM FRU file name gt Download of FRU data to PEM B sh fru_update 20 7 lt PEM FRU file name gt Download of FRU data to the SAP sh fru_update 20 8 lt SAP FRU file name gt
33. for a part number that matches your shelf manager After you install FRU data in the shelf manager you can use the fru_update command to perform any subsequent FRU data updates If you do not install FRU data into the shelf manager then the switch blades will not e key properly with the shelf manager carrier board clia fruinfo 10 0 Pigeon Point Shelf Manager Command Line Interpreter 10 FRU 0 FRU Info Warning the FRU Information contains only OxFF values skipping parse operation When updating the FRU data some specific data like serial number or product version shall be kept because the new FRU ID files coming with new firmware releases do not contain these specific data When using the frudataw command the Shelf Manager will overwrite these data The program fru_update saves and restores the variables listed below Table 1 Saved Variables Variable Name Area Info Serial number Board Info Area Serial number Chassis Info Area Serial number Product Info Area Mfg Date Time Board Info Area Product Version Product Info Area Asset Tag Product Info Area IP address OEM record Shelf Manager IP Connection Gateway OEM record Shelf Manager IP Connection Netmask OEM record Shelf Manager IP Connection Delay Time OEM Record Power Management Save all rows Order OEM Record Power Management Save all rows Min Voltage OEM Record Power Management Sa
34. fru_update 20 6 lt PEM FRU file name gt Download of FRU data to PEM B M sh fru_update 20 7 lt PEM FRU file name gt Download of FRU data to the SAP sh fru_update 20 8 lt SAP FRU file name gt For ACB IV type shelf managers see table at the top of this document for identification the following commands have to be entered Download of FRU data to the Shelf Manager in 0x10 sh fru_update 10 0 lt Shelf Manager FRU file name gt Download of FRU data to the Shelf Manager in 0x12 sh fru_update 12 0 lt Shelf Manager FRU file name gt Step 9 Reboot the Shelf Manager reboot Release Note Schroff Firmware part number 63998 04664 11 31 January 22 2008 Schroff AivanceaTCA Reliable Upgrade Procedure The Reliable Upgrade procedure will copy the new firmware flash images from an FTP server on your network to RAM on the ShMM 500 and then copy the images to flash memory STEP 1 Network settings In order to retrieve the new firmware images the Shelf Manager needs a network connection to your FTP server If this already exists through the Base Interface hub then no further network configuration is required If your Base Interface hubs are not connected to a network you can use the RJ 45 connector on the front panel of the Shelf Manager to connect to the FTP server on your network If you need to use the front panel Ethernet connector you need
35. goes well the reliable upgrade watchdog timer will be reset after Linux boots and the provisional FLASH memory will be configured as the current FLASH memory If the upgrade fails the original FLASH memory will be configured as the current FLASH memory and the Shelf Manager will reboot In the example below 192 168 0 7 is the TCP IP address of the FTP server You will need to substitute the TCP IP address of your FTP server In the example tmp is the directory on the FTP server that contains the new FLASH images You will need to substitute the directory name on your FTP server that contains the FLASH images In the example ftp is a valid userid on the FTP server and ftppw is the password for the userid You will need to substitute both ftp and ftppw for a valid userid and password on your FTP server This is an example of the Reliable Upgrade command rupgrade_tool s v k 63998 04664 shmm500 kernel r 63998 04664 shmm500 rfs u 63998 04664 u boot bin proto ftp 192 168 0 7 tmp ftp ftppw hook erase Note This command is on a single line This is an example of the Reliable Upgrade command and the response of the Shelf Manager rupgrade_tool s v k 63998 04664 shmm500 kernel r 63998 04660 shmm500 rfs u 63998 04660 u boot bin proto ftp 192 168 0 7 tmp ftp ftp hook erase rupgrade_tool PLB is 7 rupgrade_tool EEPROM page saved rupgrade_tool persistent flash is 0 rupgrade_
36. he 11596 101 Shelf into both FRU_data SEEPROMs and restores the variables listed in Table 1 sh var nvdata fru_update 20 254 var nvdata 11596101ABBIN bin p Writes Chassis FRU data of a 11596 101 Shelf into both FRU_data SEEPROMs and restores the variables in Table 1 without saving and restoring the power management data sh var nvdata fru_update 20 3 var nvdata 21596132ABBIN bin Writes Fan Tray FRU data into the FRU_data SEEPROM of the left Fan Tray Fan Tray 0 and restores the variables listed in Table 1 Complete update For a complete update of all FRU EEPROMs the following commands are necessary You can omit the path if you have cd ed to the directory containing either fru_update or the FRU Files or both e g cd var nvdata sh fru_update 10 0 21596247AB BIN bin Commands for complete update Download of FRU data to shelf SEEPROM 1 sh fru_update 20 1 lt Chassis FRU file name gt Release Note Schroff Firmware part number 63998 04664 10 31 January 22 2008 Schrof f AivanceaTCA Download of FRU data to shelf SEEPROM 2 sh fru_update 20 2 lt Chassis FRU file name gt Download of FRU data to Fan Tray 0 sh fru_update 20 3 lt Fan Tray FRU file name gt Download of FRU data to Fan Tray 1 sh fru_update 20 4 lt Fan Tray FRU file name gt Download of FRU data to Fan Tray 2 sh fru_update 20 5 lt Fan Tray FRU file name gt Download of FRU data to PEM A sh
37. imer activated Setting hostname shmm500 ted ram disk to var log ted syslogd and klogd ted ram disk to var tmp Strobing the reliable upgrade WDT dev mtdblock1l appears to be empty restoring from factory etc Preserved ssh_host_dsa_key in etc ssh Preserved ssh_host_rsa_key in etc ssh Mounted dev mtdblock1l to etc Calling etc rc acb4 for acb4 acb4 acb4 acb4 acb4 acb4 acb4 2007 16 44 14 lt gt 11 44 11 418 lt gt 11 44 11 420 lt I gt 11 44 11 431 OSs S U S 5 S C 5 shmm500 login Hardware Address 0x10 etc hosts updated with shmm500 192 168 0 22 entry Updating etc profile sentry with IP settings ifconfig eth0 192 168 0 22 netmask 255 255 255 0 route add default gw 192 168 0 1 Starting bin inetd Starting time synchronization with 192 168 0 7 tarting pdating tarting tarting tarting trobing t 192 168 0 7 and service ntp up IPMBs etc profile sentry with specific settings snmpd httpd Shelf Manager for carrier type ACB ommand line shelfman sf the reliable upgrade WDT 235 Pigeon Point Shelf Manager ver 2 5 1 Built on Jul 30 235 Lock log print buffer at 10053260 235 Pthread lock log print buffer at 100572b0 235 Reading configuration file etc shelfman conf You can verify the version that you are running with the version command version Release Note Schroff Firmware part number 63998 0466
38. kernel and sentry shmm500 rfs images inside this special boot image TFTP boot the upgrade kernel and RFS images on your ShMM 500 Once booted the upgrade script will automatically update your SAMM 500 using the rupgrade_tool utility and the new 2 5 1 kernel and RFS and u boot images stored in the upgrade RFS image It will then reboot For customers with early production F64M128 large capacity SaMM 500 modules an additional step may be performed to reprogram the ADM1060 to enable the larger flash memory Step 1 Rename the kernel and RFS files gt Rename 63998 04664 kernel to sentry kernel gt Rename 63998 04664 rfs to sentry rfs These images need to be placed on a TFTP server machine that is network reachable from the ShMM 500 module Step 2 Power on your ShMM 500 based hardware and interrupt the boot up process by pressing the space bar on the serial port console of the SAMM 500 U Boot Llafur Shmm500 Step 3 Verify the correct name of the download images Make sure that the renamed files of Step 1 correspond to the required file names in u boot Shmm500 printenv boot file sentry kernel ramdisk sentry rfs Step 4 Make sure that the network settings for your SAMM 500 are such that it can see the TFTP server on your network shmm500 printenv serverip ipaddr netmask gatewayip serverip 192 168 0 7 ipaddr 192 168 0 2 netmask 255 255 0 0 gatewayip 192 168 0 1 Release Note Schroff Firmware part number 63998 0
39. lia frudata 10 0 var nvdata lt Shelf Manager FRU file name gt and clia frudata 12 0 var nvdata lt Shelf Manager FRU file name gt to install FRU data into the shelf manger You will need to substitute lt Shelf Manager FRU file name gt for a part number that matches your shelf manager After you install FRU data in the shelf manager you can use the fru_update command to perform any subsequent FRU data updates If you do not install FRU data into the shelf manager then the switch blades will not e key properly with the shelf manager carrier board clia fruinfo 10 0 Pigeon Point Shelf Manager Command Line Interpreter 10 FRU 0 FRU Info Warning the FRU Information contains only OxFF values skipping parse operation When updating the FRU data some specific data like serial number or product version shall be kept because the new FRU ID files coming with new firmware releases do not contain these specific data When using the frudataw command the Shelf Manager will overwrite these data The program fru_update saves and restores the variables listed below Table 1 Saved Variables Variable Name Area Info Serial number Board Info Area Serial number Chassis Info Area Serial number Product Info Area Mfg Date Time Board Info Area Product Version Product Info Area Asset Tag Product Info Area IP address OEM record Shelf Manager IP Connection
40. o be finalized in an upcoming 2 5 x update 4 A switchover on deactivation of the physical active Shelf Manager is now supported Now if the configuration parameter SWITCHOVER_ON_HANDLE_OPEN is set a programmatic deactivation of the physical Shelf Manager also initiates a switchover to the backup Shelf Manager To allow this physical Shelf Managers are now not affected by global power down and power cycle operations such as those initiated due to a thermal critical alert or via the IPMI command Chassis Control 5 The Shelf Manager now does not consider that an IPM controller has been replaced and preserves the identification of that IPM controller if only the Firmware Revision and or Auxiliary Firmware Revision fields are changed in the Get Device ID response for the IPM controller This allows the Shelf Manager to better distinguish firmware upgrades of an IPM controller from the removal and reinsertion of a different IPM controller 6 The major Shelf Manager interface facilities specifically the CLI and the RMCP interface are now monitored for deadlocks by the watchdog timer A deadlock that makes either of those Shelf Manager interfaces unresponsive now causes the hardware watchdog timer to trigger and reset the Shelf Manager the backup Shelf Manager takes over In that case a dump of the current state of the Shelf Manager s internal locks is written to the file Nar nvdata dumplog bin on the Flash file system This file can b
41. ommand version The output shows the version of u boot Linux Kernel and RFS image for both the current FW version and the alternative FW version in flash At the end of the output the version of the shelfman application is displayed version Current Boot Image Name 63998 04664 uboot bin 1 1 4 Created Mon Jan 21 15 36 19 2008 Image Type MIPS Linux Firmware uncompressed Data Size 183836 Bytes 179 53 kB 0 18 MB Load Address 0x9FC00000 Entry Point 0x00000000 Current Kernel Release Note Schroff Firmware part number 63998 04664 7 31 January 22 2008 Image Name Created Image Type Data Size Load Address Entry Point Current RFS Image Name Created Image Type Data Size Load Address Entry Point Alternate Boo Image Name Created Image Type Data Size Load Address Entry Point Alternate Lin Image Name Created Image Type Data Size Load Address Entry Point Alternate RFS Image Name Created Image Type Data Size Load Address Entry Point Pigeon Poin Running on th Pigeon Poin Pigeon Poin Schroff Aivancea TGA 63998 04664 kernel Linux 2 4 26 Mon Jan 21 15 36 19 2008 MIPS Linux Kernel Image 855848 Bytes 835 79 kB 0x80100000 0x802C6040 gzip compressed 0 82 MB 63998 04664 RFS Mon Jan 21 15 36 19 2008 MIPS Linux RAMDisk Image gzip compressed 3508822 Bytes 3426 58 kB 3 35 MB 0x00000000 0x00000000 T 63998 04662 ubo
42. ot bin 1 1 4 Tue Jan 8 15 27 50 2008 MIPS Linux Firmware uncompressed 183836 Bytes 179 53 kB 0 18 MB 0x9FCO0000 0x00000000 ux 63998 04662 kernel Linux 2 4 26 Tue Jan 8 15 27 49 2008 MIPS Linux Kernel Image gzip compressed 855848 Bytes 835 79 kB 0 82 MB 0x80100000 0x802C6040 63998 04662 RES Tue Jan 8 15 27 49 2008 MIPS Linux RAMDisk Image 3508822 Bytes 0x00000000 0x00000000 gzip compressed 3426 58 kB 3 35 MB Shelf Manager Command Line Interpreter e Backup Shelf Manager with limited functionality Shelf Manager ver 2 5 1 is a trademark of Pigeon Point Systems Copyright c 2002 2007 Pigeon Point Systems All rights reserved Build date time Jul 30 2007 16 44 14 Carrier ACB Carrier subtype 4 subversion 0 Step 8 Updating FRU data files Change to the var nvdata directory cd var nvdata Do not use the Release Note Schroff Firmware command clia frudataw to update the FRU ID files part number 63998 04664 8 31 January 22 2008 Schroff AivanceaTCA Note The only exception to this recommendation is for ACB IV shelf managers that do not contain FRU data This will be true for most ACB IV shelf managers that originally shipped with firmware V2 3 2 or earlier You can check for the presence of shelf manager FRU data with the commands clia frudata 10 0 and clia frudata 12 0 If you get a response like that shown below then you need to use the commands c
43. rkarounds for this version 3 Missing Fan Presence sensors Implication Fan Tray insertion or de insertion will not create an event on the Shelf Manager Workaround Monitor an alternate event such as the Hot Swap Sensor 4 Limited ACB IV Sensors Recognized Implication Voltage and Fuse sensors are not part of the SDR records and will not be operational Workaround There are no workarounds for this version Bug fixes 1 The Shelf Manager could reboot due to watchdog expiration if clia utility was suspended while producing the output e g in commands like clia sensordata more 2 In rare circumstances the Shelf Manager could fail and reboot during initial startup when an attempt was made to access Shelf FRU Info before the Shelf FRU Info subsystem in the Shelf Manager was initialized 2 5 New and changed features 1 Updated release of Monterey Linux This release in based on an update of Monterey Linux that has the following new features ShMM 500R The USB device driver has been fixed to properly handle errors that may occur during direct memory access operations Without this fix the USB connection between active and backup Shelf Managers might break unexpectedly and be restored only by a backup Shelf Manager reboot ShMM 5OOR The utility wimp has been removed from busybox because it can cause unbounded growth of the login log in RAM Release Note Schroff Firmware part number 63998 04664 24 31 January 22
44. server You need to substitute 192 168 0 6 in the command for the IP address of the FTP server on your network The example below shows a successful ping test ping e 2 192 168 0 6 PING 192 168 0 6 192 168 0 6 56 data bytes 64 bytes from 192 168 0 6 icmp_seq 0 ttl 64 time 1 5 ms 64 bytes from 192 168 0 6 icmp_seq 1 ttl 64 time 1 9 ms gt 192 168 0 6 ping statistics 2 packets transmitted 2 packets received 0 packet loss round trip min avg max 1 5 1 7 1 9 ms Connect a serial console cable to from a terminal or PC running a terminal emulator Hypercom Minicom Hyperterminal etc to the console port of the Shelf Manager Set the terminal or emulator to 115200 N 8 1 115200 baud no parity 8 bits per character 1 stop bit STEP 2 Upgrade Process Release Note Schroff Firmware part number 63998 04664 12 31 January 22 2008 Schrof Ff AivanceaTCA Put the three Reliable Upgrade FLASH images 63998 04664 shmm500 kernel 63998 04664 shmm500 rfs 63998 04664 u boot bin on an FTP server that is on the same network as the Shelf Managers For this example the Reliable Upgrade FLASH images were put in the tmp directory on the FTP server A single command is executed on the active Shelf Manager to upgrade the FLASH images This command will download the FLASH images using FTP copy them into the alternate FLASH memory configure the Shelf Manager for a provisional boot and reboot the Shelf Manager If all
45. t Swap button was deactivated programmatically and then extracted from the shelf it was not necessarily re activated automatically after the reinsertion the command clia activate or additional pressing of the button was necessary 5 The help text produced by the clia help command was not specific enough regarding address parameters whether a hardware address or an IPMB address is expected 6 An SDR could remain in the SDR Repository after the Clear SDR Repository IP MI command 7 A crash of the Shelf Manager was possible when the file var nvdata sdrrepository was corrupted in a specific way 8 The chassis id SNMP variable always returned even though writing was done properly 9 An SNMP set operation could fail if the value to be set was 0 10 The fru device activated SNMP variable didn t work with FRUs in M1 and couldn t do deactivation properly 11 An incorrect DHCP request could be sent when a switchover occurred before a reply from any DHCP server 12 The Chassis Control Power Cycle IPMI command could cause a non zero FRUs to get stuck in state M1 on ECN 002 compliant IPM controllers 2 4 3 New and changed features 1 Updated releases of Monterey Linux This release in based on updates of Monterey Linux that have the following new features ShMM 500 Merged patches into base ML release ShMM 500 Added U Boot fix for an md 0 hang ShMM 500 Added NFS mount capability to busybox mount ShMM 500
46. to set the jumpers on the Shelf Manager to route the primary Ethernet port to the front panel When the jumpers are on the pins towards the front panel the Ethernet is connected to the front panel connector See the Shelf User Manual for details of the jumper setting You need to configure the IP Address that the Shelf Manager will use on the network to access the FTP server The command clia setlanconfig 1 ip 192 168 0 2 will set the IP Address of the active Shelf Manager to 192 168 0 2 The active Shelf Manager is the one with the green LED illuminated and not blinking You need to substitute 192 168 0 2 in the example for your desired IP Address If your Shelf Manager is on a different network than your FTP server then you need to configure the Default Gateway The command clia setlanconfig 1 dft_gw_ip 192 168 0 1 will set the IP Address of the Default Gateway to 192 168 0 1 You need to substitute 192 168 0 1 in the example for the IP Address of the Default Gateway on your network If you use subnets on your network then you need to change the Subnet Mask from the default value of 255 255 255 0 The command clia setlanconfig 1 subnet_mask 255 255 255 128 will set Subnet Mask of the Subnet Mask to 255 255 255 128 You need to substitute 255 255 255 128 in the example for the Subnet Mask of your network You can use the command ping 192 168 0 6 to test the network connection to the FTP
47. tool provisional flash is 1 rupgrade_tool copying image s rupgrade_tool copying 63998 04664 u boot bin from 192 168 0 7 to tmp using ftp protocol 220 FileZilla Server version 0 9 22 beta 220 Schroff Development FIP Server 220 Please visit http sourceforge net projects filezilla USER ftp 331 Password required for ftp PASS KKKKK 230 Logged on TYPE I 200 Type set to I PASV 227 Entering Passive Mode 192 168 0 7 6 199 RETR 63998 04664 u boot bin 150 Connection accepted 226 Transfer OK QUIT 221 Goodbye rupgrade_tool copying 63998 04664 shmm500 kernel from 192 168 0 7 to tmp usi ng ftp protocol 220 FileZilla Server version 0 9 22 beta 220 Schroff Development FTP Server 220 Please visit http sourceforge net projects filezilla USER ftp 331 Password required for ftp Release Note Schroff Firmware part number 63998 04664 13 31 January 22 2008 Schroff Aivancea TGA PASS kkxkxk xx 230 Logged on TYPE I 200 Type set to I PASV 227 Entering Passive Mode 192 168 0 7 6 200 RETR 63998 04664 shmm500 kernel 150 Connection accepted 226 Transfer OK QUIT 221 Goodbye rupgrade_tool copying 63998 04664 shmm500 rfs from 192 168 0 7 to tmp using ftp protocol 220 FileZilla Server version 0 9 22 beta 220 Schroff Development FIP Server 220 Please visit http sourceforge net projects filezilla USER ftp 331 Password required for ftp PASS KKK KK
48. ve all rows Max Current OEM Record Power Management Save all rows Power OEM Record Power Management Save all rows Consumption Internal Use Area Complete Release Note Schroff Firmware part number 63998 04664 17 31 January 22 2008 FRU ID file upgrade Schroff AivanceaTCA The syntax is sh lt path gt fru_update lt IPMC gt lt FRU ID gt lt path gt lt filename gt lt options gt The table below lists valid values for lt IPMC gt and lt FRU ID gt lt IPMC gt lt FRU ID gt Description 10 0 Shelf Manager 1 20 1 Shelf SEEPROM 1 20 2 Shelf SEEPROM 2 20 254 Both Shelf SEEPROMs 20 3 Fan Tray 0 20 4 Fan Tray 1 20 5 Fan Tray 2 20 6 PEM 0 20 7 PEM 1 20 8 SAP lt path gt Location of the FRU files normally var nvdata lt filename gt Name of the FRU file Example 11596032BABIN bin 11596032 Product name BA Revision of the FRU data file BIN Identification for a FRU data file bin Format of FRU data file lt options gt p The power management section will not be saved and restored Examples sh var nvdata fru_update 20 254 var nvdata 11596101ABBIN bin Writes Chassis FRU data of the 11596 101 Shelf into both FRU_data SEEPROMs and restores the variables listed in Table 1 sh var nvdata fru_update 20 254 var nvdata 11596101ABBIN bin p Writes Chassis FRU data of a 11596 101 Shelf into both FRU_data SEEPROMs and r