1. Control method Continuous proportional control PID constant setting Setting possible by auto tuning PID constant range Proportional band P Thermocouple 0 1 to full scale C Microvoltage voltage current 0 1 1000 0 Integral time I 0 0 to 3276 7s Differential time D 0 0 to 3276 7s Set value setting range Thermocouple Input range of thermocouple being used Specified input range for Microvoltage voltage current Dead band setting range 0 1 to 10 0 Isolation specifications Isolation method Specific isolated area Dielectric withstand voltage 500VAC for 1 minute Between input and ground Transformer isolation Between input channels Insulation resistance 500VDC for 20MQ or more FeRAM reading writing times Max 10 times Number of I O occupied points 16 points I O assignment intelligent 16 points Connector 18 point terminal block Applicable wire size 0 3 to 0 75mm Applicable solderless terminal R1 25 to 3 use of crimped terminal with sleeve is prohibited External power supply DC24V 20 15 Ripple spike 500mVp p or less Inrush current 0 2A 4us or less 0 07A Internal current consumption 0 27A Weight 0 25kg External dimensions 27 4 W x 98 H x 112 D mm 1 Accuracy is calculated as follows Accuracy Command accuracy Reference junction tempera
2. Less than 100 C 2 0 Ke Ji PEI 100 to less than 500 C LOG 500 C or more Command value x 0 2 1 digit S R N 50 to less than 1000 C 2 0 C Thermocouple prg W5Re W26Re 1000 C or more Command value x 0 2 1 digit Less than 400 C 140 0 C B 400 to less than 1000 C 2 0 C 1000 C or more Command value x 0 2 1 digit Microvoltage Voltage Current Full scale x 0 2 Features C 6 Online Module Change Hot Swap In the event of Q62HLC failure the Q62HLC can be replaced without stopping the system 1 Online module change can only be used with process CPU QnPHCPU 7 RFB Reset FeedBack Limiter When a deviation continues for an extended period of time the RFB reset feedback limiter function performs an integral control action to prevent the PID operation result s manipulated value MV from exceeding the valid manipulated value MV range The RFB limiter also prevents overshooting which can easily occur at startup and when the set value SV is increased etc 8 Sensor Compensation A sensor compensation value can be specified to prevent deviations between process values PV and the actual temperature humidity pressure and flow rate 9 Loop Disconnection Detection This function detects control loop faults caused by problems with the load external operation device and inputs sensor etc The following Q62HLC operations are performed if an i
3. Supported thermocouples K J T S R N E B PL I W5Re W26Re When using simple analog output Input characteristic See item 2 Output characteristic Digital value 0 to 4000 Output range 4 to 20mA Maximum resolution See item 2 Maximum resolution 4uA Ambient temperature 7 gt Ambient temperature te Yo Z 23c 2 C See item 3 a E EO EAE Full scale x 0 2 GE E B Ambient temperature 53 Ambient temperature Liss See item 3 b or Full scale x 0 4 g O S o C to 55 C 3 0 C to 55 C Ambient temperature Q i 0 lt JE osc 2 C oe EE A 3 Ambient temperature P 68 1 0C0 O 0 C to 55 C Conversion speed 25ms 2 channels constant regardless of the number of channels used Speed change rate 25ms 2 channels constant regardless of the number of channels used Sampling period 25ms 2 channels constant regardless of the number of channels used Absolute max input Microvoltage 12V Voltage 15V Current 30MA Permissible load resistance 6002 or less Input impedance Normal mode rejection ratio Thermocouple Microvoltage Voltage 1M Current 2502 Output impedance 60dB or more 50 60Hz 5MQ Specifications Common mode rejection ratio 120dB or more 50 60Hz Input filter Primary delay digital filter 0 0 to 100 0s Sensor compensation value setting 50 00 to 50 00
4. del Valles Barcelona Spain NO 11 Kawasan Industri Pergudangan Jakarta Utara 14440 France Mitsubishi Electric Europe B V French Branch Tel 33 1 5568 5568 a Messung Systems Pvt Lid Wetec al AAE 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Fax 33 1 5568 5685 aioe ae NO 111 Unit No15 M I D C Bhosari Pune Fax 91 20 2712 8108 India South Africa Circuit Breaker Industries LTD Tel 27 11 928 2000 ee E 7 Private Bag 2016 1600 Isando Tripswitch Drive Elandsfontein Fax 27 11 392 2354 Australia Mitsubishi Electric Australia Pty Lid TOL pelea GSA TTT Gauteng South Africa 348 Victoria Road Rydalmere N S W 2116 Australia Fax 61 2 9684 7245 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd Tel 852 2887 8870 10 F Manulife Tower 169 Electric Road North Point Hong Fax 852 2887 7984 Kong China Mitsubishi Electric Automation Shanghai Ltd Tel 86 21 6475 3228 1 3 F Block5 103 Cao Bao Road Shanghai 200233 China Fax 86 21 6474 6996 sfa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADAMINAMI 5 HIGASIKU NAGOYA JAPAN 0510 MDOC Specifications subject to change without notice Printed in Japan on recycled paper
5. 86 2 2299 2509 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Tel 55 11 5908 8331 Taiwan Rua Correia Dias 184 Edificio Paraiso Trade Center 8 ander Fax 55 11 5574 5296 Korea Mitsubishi Electric Automation Korea Co Ltd Tel 82 2 3660 9552 Paraiso Sao Paulo SP Brazil Dong seo Game Channel Bldg 2F 660 11 Deungchon dong Fax 82 2 3664 8372 Germany Mitsubishi Electric Europe B V German Branch Tel 49 2102 486 0 Kangseo ku Seoul 157 030 Korea Gothaer Strasse 8 D 40880 Ratingen GERMANY Fax 49 2102 486 7170 Singapore Mitsubishi Electric Asia Pte Ltd Tel 65 6470 2460 U K Mitsubishi Electric Europe B V UK Branch Tel 44 1707 276100 307 Alexandra Road 05 01 02 Fax 65 6476 7439 Travellers Lane Hatfield Herts AL10 8XB UK Fax 44 1707 278695 Mitsubishi Electric Building Singapore 159843 Italy Mitsubishi Electric Europe B V Italian Branch Tel 39 039 60531 Thailand FSA Tech Cou Ltd ot eT Us Oe pee Goce Centro Dir Colleoni Pal Perseo Ingr 2 Fax 39 039 6053312 896 19 20 21 22 S V City Building Office Tower 1 Floor Fax 66 2 682 6020 Via Paracelso 12 20041 Agrate Brianza Milano Italy 12 Rama Ill Rd Bangpongpang Yannawa Bangkok 10120 Spain Mitsubishi Electric Europe B V Spanish Branch Tel 34 93 565 3131 Indonesia P T Autoteknindo SUMBER MAKMUR Tel 62 21 663 0833 Carretera de Rubi 76 80 Fax 34 93 589 2948 Muara Karang Selatan Block A Utara No 1 Kav Fax 62 21 663 0832 E 08190 Sant Cugat
6. C supports thermocouples which comply with the JIS IEC NBS and ASTM standards Items complying with any of these standards can be used NBS Stands ind ASTM Standard T J 3 Supports Variety of Input Ranges The use of an input sensor microvoltage voltage and current inputs enables analog value measurements in the ranges shown below JIS Standard IEC Standard Voltage Current 0 to 10mV Oto 1V 0 to 100mV 1 to 5V 4 to 20mA 10 to 10mV 0 to 5V 0 to 20mA 2 1 to 1V 100 to 100mV a N 10 to 10V 4 Program Control Function Control program profiles can be specified where set values SV and PID constants proportional band P integral time I differential time D are automatically changed at specified times SV Program control using 16 segment program profile Time 5 Cascade Control Function Cascade control can be performed with channel 1 as the master and channel 2 as the slave Resin nozzle temperature control rformance specifications 1 Performance specifications Number of input points Analog input specifications 2 points 2 channels 2 channels per module Number of output points Item Specifications Number of analog input output points Analog output specifications Specifications 2 points 2 channels Analog input See item 2 Digital input Binary with 16 bit symbol Digital output 16 bit binary value Analog output Current
7. Changes for the Better Mi iI MN il October 2005 New Product Release No 235E Q62HLC Loop Control Module j The New Loop Control Module e Control of rapid temperature increases at flip chip bond IC manufacturer Ideal For Fast Response Control ee e Drying oven cooling temperature control on freeze drying machines Q Staggering 25ms sampling and control update time an industry first Supports sensor types such as thermocouple microvoltage voltage and current input Continuous proportional PID control by 4 to 20mA current output results in highly stable and accurate control ranges a A l y l Q62HLC om Mitsubishi Electric Corporation Nagoya Works is a factory certified for 15014001 standards for environmental management systems and ISO9001 standards for quality assurance managememt systems KA QUALITY MANAGEMENT ENVIRONMENTAL MANAGEMENT EC97J1113 1 High Speed PID Control The Q62HLC loop control module uses a continuous proportional PID control format which features a sampling period of 25ms for high accuracy high resolution thermocouple inputs microvoltage inputs voltage inputs current inputs and current outputs These features make the Q62HLC ideal for applications such as rapid temperature increase control pressure control and flow rate control 2 Connectable to Thermocouples that Comply with Major International Standards The Q62HL
8. GX Configurator TC is available Although the module can be setup using standard ladder programming Using this utility tool greatly simplifies setup without the need for any extra programming Diagnostics can also be performed DAEK E O pE e Q62HLC RUN ALM Unit mm ERR ME avoc T Paim NCE ti Ld o Gle o L D an ine co a 10 vA T Cul yal 13 14 Pa EBAT ma NOIE Tiria M3 screw A fhe 3 accessory item M3 screw 49 L bracket for accessory item FG terminal J accessory item 112 27 4 Product name Model Model code Q62HLC type Loop Control Module Q62HLC 1W4257 GX Configurator TC Version 1 SWOD5C QTCU E 1 13PX16 1 Version 1 20W and later are supported Related manuals Manual name VEUVE 0 EELO IB SH No Model code Loop Control Module User s Manual F He Included with product IB 0800319 13JP75 Hardware Edition P Loop Control Module User s Manual p Sold separately SH 080573ENG 13JR85 Country Region Sales office Tel Fax Country Region Sales office Tel Fax U S A Mitsubishi Electric Automation Inc Tel 1 847 478 2100 Taiwan Setsuyo Enterprise Co Ltd Tel 886 2 2299 2499 500 Corporate Woods Parkway Vernon Hills IL 60061 Fax 1 847 478 2396 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Fax 8
9. nput disconnection occurs Input Input Range Operation Thermocouple All Up scale 2 Microvoltage Woltane 1 to 5V Down scale 3 g 0 to 1V 1 to 1V 0 to 5V 5 to 5V O to 10V 10 to 10V OV vicinity value displays 4 4 to 20mA Down scale Current a 0 to 20mA OmA vicinity value displays 4 2 Displays the input range upper limit value full scale x 5 value 3 Displays the input range lower limit value full scale x 5 value 4 No alarm is activated at any channel even channels where no sensor is connected because the process value PV is in the input range 10 Scaling This function automatically saves a scaled process value PV to the buffer memory 1 1 Simple Analog Input Output This function allows the Q62HLC to serve as a simple thermocouple microvoltage input module a DI module or an Al module by monitoring the process value PV and manually setting the manipulated value MV 1 2 Auto Tuning Mode Setting This functions permits an auto tuning mode to be specified for the set control value by setting the AT auto tuning operation gap time and the AT insertion loss time 13 Setting Data Backup Buffer memory setting data can be backed up to an FeRAM If data is written directly to the buffer memory by using GX Developer TEST function the minimum requirement sequence program LD OUT Yn1 is adequate 14 Easy Setting Using Utility Package An optional utility package
10. ture compensation accuracy 2 Supported I P Sensor Types And Characteristics Input Input Range Digital Value Resolution K 200 to 1372 C 2000 to 13720 J 200 to 1200 C 2000 to 12000 I 200 to 400 C 2000 to 4000 S 50 to 1768 C 500 to 17680 R 50 to 1768 C 500 to 17680 0 1 C Thermocouple N 0 to 1300 C 0 to 13000 E 200 to 1000 C 2000 to 10000 B 0 to 1800 C 0 to 18000 PLI 0 to 1390 C 0 to 13900 W5Re W26Re 0 to 2300 C 0 to 23000 0 to 10mV 0 5uV 0 to 20000 0 to 100mV 5uV Microvoltage 10 to 10mV 1uV 10000 to 10000 100 to 100mV 10uV Oto 1V 0 05mV 1 to 5V 0 2mV 0 to 20000 0 to 5V 0 25mV Voltage 0 to 10V 0 5mV 1to 1V 0 1mV 5 to 5V 10000 to 10000 0 5mV 10 to 10V imV 4 to 20mA 0 8uA Current 0 to 20000 0 to 20mA 1A 3 Command Accuracy a With ambient temperature of 23 2 C Less than 100 C 1 0 C Ker ele 100 to less than 500 C 0 5 C 500 C or more Command value x 0 1 1 digit S R N 50 to less than 1000 C 1 0 C Thermocouple Lateran W5Re W26Re 1000 C or more Command value x 0 1 1 digit Less than 400 C 70 0 C B 400 to less than 1000 C 1 0 C 1000 C or more Command value x 0 1 1 digit Microvoltage Voltage Current Full scale x 0 1 b With ambient temperature of 0 to 55 C

Download Pdf Manuals

image

Related Search

Q62HLC q60hls-24v-r q62 icd 10

Related Contents

LASER: A LAyout Sensitivity ExploreR Report and User's Manual  287998-38439-9031_IW 120-180_de_en_fr_cs_ru    Mort d`une petite fille de 7 ans, solidarité avec l`école Marie Curie de  Metropolis DGT -PT  Life Fitness LS-9500 User's Manual  Samsung CL-25A6W Manual de Usuario  取扱説明書  工事・保守マニュアル  TDSHーBA 東芝電球ペンダン ト取扱説明書 保管用  