installation manual - ADSF
Contents
1. COMUHICRTIOH SET UP ET UP 4 b PASSL WORD SET UF UP 4 pce Bo FAS UNUSED SERIAL COMMUNICATION SERVICE SET UP SECTION PASSWORD MANAGEMENT SECTION SECTION e Refer to par 14 4 when entering the initial set up section e If entering the serial communication setting section please refer to para 14 3 e For the other sub menus refer to the following paragraph on the section you have had access to 37 19 FUNCTIONS AND SETTINGS To enter type 10 character technical password for more information refer to Password management paragraph i EXIT 1 The buttons in this sub menu are used as follows button F2 to access the F function setting see the Function setting paragraph button to access the P parameter setting see the Parameter setting paragraph button F1 issue the door opening command button F3 itis only used in case the S12 digital programmer is connected to two operators to choose whether to act on the functions and parameters of operator 1 or of operator 2 The number 1 or 2 at the top right of the display indicates the selected operator If the 12 programmer is connected to a single operator the number 1 appears at the top right of the display button to return to the general programming menu 19 1 FUNCTION SETTING AA SELECTOR SELECTION JAA f kie MECHANICAL W SELECTOR OFF In this section the display describe
2. Periodically check battery efficiency LED SIGNALLING To allow recharging batteries must always be connected to the electronic control unit SIGNALLED EVENTS GREENGREEN LEDLED EDRED LEDLED The equipment must be disconnected from the mains when BATTERY DISCONNECTED ON ON removing the batteries In case of replacement always use genuine batteries BATTERY CHARGING BLINKING OFF Replacement must be performed by qualified personnel Remove batteries from the equipment before its disposal BATTERY CHARGED WITH MAINS VOLTAGE ON OFF Batteries contain polluting substances therefore they must be LOW OR DAMAGED BATTERY WITH AND WITHOUT MAINS VOLTAGE OFF BLINKING disposed of in accordance with the provisions of local regulations BATTERY CHARGED WITHOUT MAINS VOLTAGE OFF ON 33 17 PROGRAM SELECTORS The program selector allows the door user to select the operating mode Depending on one s preferences the EV MSEL mechanical key selector or the 12 digital programmer can be used Each program selector is described in details below e e 17 1 EV MSEL MECHANICAL KEY SELECTOR The operation of the 5 position mechanical key selector must be enabled by setting the F01 function to ON on the N DSEL programmer S ELECTRIC CONNECTIONS Terminal 1 of EV MSEL to terminal 8 Internal radar of EUROSLIDER operator control unit Terminal 2 of EV MSEL to terminal 11 Common of EUROSLIDER operator control unit Terminal 3 of E
3. M8 8 OPERATOR 1 OPERATOR 2 ON ON 7 7 o3 o3 2 2 DIP7 OFF DIP7 ON DIP2 OFF DIP2 OFF 27 14 COMMISSIONING OF AUTOMATED DEVICE INITIAL SET UP After performing the mechanical installation of the automatic door and the electrical connections to the electronic control unit you can start up the automated equipment Preliminary checks check the cleanliness of the sliding rail and of the ground guide check the belt s tension check that leaves are properly aligned and fastened to chariots check that the position of the mechanical limit switch is correct check that leaves move smoothly and frictionless check proper operation of the electric lock if installed and of the relevant manual release SET UP operation is compulsory to allow the operator electronic control unit to acquire stroke points During the stroke learning cycle there must be no obstacles in the leaf movement area If the 12 digital programmer is used to manage a single EUROSLIDE automatic door dips 1 and 2 of the S3 dip switch on the LOGIC2 operator control unit bust be set to OFF If the 12 digital programmer is used to manage two EUROSLIDE automatic doors dips 1 and 2 of the S3 dip switch on the LOGIC2 control unit of operator 1 must be set to OFF while on the LOGIC2 control unit of operator 2 dip 1 must be set to ON and dip 2 to OFF see Table Before powering the system set the S3 dip switch of the LOGIC2 logic board as specifie
4. oignage Affixed Left on Site Technician Signature _ Date amp Time A www adsf co uk LOG BOOK Company Name amp Address Installer Name Site Address Install Date Unit ID No Operators Installed Activation Devices Sensor Push Pad Keyfob Access Control Safety Devices Threshold Sensor Side Screen Sensor On Door Sensor Barriers Escape System Break Out Doors Y N Break Out Force N Battery Back Up Battery Settings F O CONT Repair Maintenance History Date Works Carried Out Signature Manufacturer ADSF Unit 3 Millers Court Windmill Road Bristol BS21 6UL LOG BOOK Repair Maintenance History Signature Name Works Carried Out _ NEN SEN NEN MEN VEN NEN NEN s NEN s 1 pd VEN NEN NEN MEN NEN NEN NEN WEN NEN a EN EN NEN BEEN NEN NEN a
5. UNIT LENGTH LT 2PL B S 24 PL LT B S 2 12 LT LM 397 LC F M 120 x2 DOUBLE LEAF DOOH WITH SLIM ELECTHIC LOCK PL T j umm LT TRANSOM PL FREE LM LEAF E LENGTH PASSAGE WIDTH F n p LT 2PL B 2S 24 PL LT B 2 S 6 LM 4 2 6 LC BELT M MOTOR C CONTROL UNIT E ELECTRIC LOCKLENGTH 400mm 345mm 1 2 5mm LC F M 120 x2 SINGLE DOOR RH LEAF WITH SLIM ELECTRIC LOCK LT TRANSOM PL FREE LM LEAF l LENGTH PASSAGE WIDTH F MER LT 2PL B S 24 PL LT B S 2 12 LM LT B S 2 12 M MOTOR C CONTROL UNIT E ELECTRIC 20 cca LT LM 467 LT LM 522 LOCKLENGTH LT 62 LC F M 120 x2 SINGLE DOOR LH LEAF WITH SLIM ELECTRIC LOCK 41 LI LT TRANSOM PL FREE LM LEAF LENGTH PASSAGE WIDTH S PULLEY LT 2PL B S 24 PL LT B S 2 12 LM LT B S 2 12 87 M MOTOR C CONTROL UNIT E ELECTRIC LT LM 342 LT LM 397 LOCKLENGTH 75 LC F M 120 x2 5 COVERING CASING The casing of the EUROSLIDE automated equipment features two support links A specially designed to ensure that it remains stable in the opening position To fully remove the casing from the automated equipment press the end section of the pins B located on the support links and extract them by pulling them from the opposite end Fig 1 Manually support the casing before extracting the pin In the lower section of the casing you can install an optional
6. Clean sensors and check that presence detectors activate properly Once maintenance is completed reset the partial cycle counter and the event memory see paragraph 23 MAINTENANCE Warning any potentially damaged or worn component must be replaced Make use only of original spare parts for this purpose check ADSF UK price list www adsf co uk 60 MAINTENANCE PROGRAM Premis Euroslide Operator Maintenance program for sliding door Premis Euroslide Each 6 month Warning Before work on the operator cut main power line Check that all securing screws are well tightened Clean and lubricate moving and sliding components Lubricate closing spring if present Check wiring connections Check that arm connection screw are well tightened Check that the door wing is stable and that the movement is fluent and with no friction from door open position up to door closed position Check the condition of the hinges and lubricate it Check that speeds timing and safety functions are well adjust Check that safety and activation sensor are properly functioning Warning Any part that appear damaged or worn must be changed Make use only of original spare parts for this purpose check price list Check that the doors are compliant to BS EN16005 61 UK LTD NBS Specification Premis Euroslide single sliding door system The Premis System operator can be adapted to the needs of each installation
7. 1000mm e Door height 2000mm 3000mm e Finish Anodised silver Polyester powder coated standard BS colours Polyester powder coated standard RAL colours e Glazing As standard Double glazed available on request e Control Digital Selector Key Switch e Safety amp security Intelligent self learning movement and presence sensors across door threshold Rear edge presence sensors for back of door safety Monitored battery backup provides up to 30 minutes operation in the event of a mains power failure lectric Motor 40Vdc with encoder i Max 70 cm s per lea losing Speed 60 ause Time Max 20 o ner leaf o aa Working Temperature Degree of Protection ower Supply Of External Accessories 0 ransom Dimension Umm x 150mm 210mmxi20mm ransom Length 500mm requency Of Use BS7036 Part 2 1996 Authorized Technician Checklist Company Name amp Address Installer Name Site Address Date Door Location General Times s Activation Distances mm Opening Time Closing Time Hold Open Time Straight Approach Straight Approach Closing Energies Drawing In Protection Check Speed J Max Speed J Entrapment N Safety Barrier Y N Finger Guards Y N Safety Devices Photocells Y N Photocell Height mm On Door Safety Sensors Escape System Break Out Doors Y N Break Out Force N Battery Back Up Battery Settings F O CONT Engineers Notes
8. compensating profile allowing to close the gap between the fixture and the casing thus improving the automated equipment appearance To adjust the compensating profile depth you must detach the casing from the automated equipment and put it on a flat surface FIG 3 Arrange the compensating profile as shown in the figure and fasten it to the casing by means of the special plastic clips Choose the optimum adjustment depth for the compensating profile referring to Fig 4 then fasten each plastic clip by first inserting the clip teeth into the compensating profile grooves and then pushing the upper section of the clip forward until it connects to the casing Put the casing back in place on the automated equipment by reinstalling the support links with the special pins then close the casing over the automated equipment hooking the upper section to the transom FIG 5 Fasten the casing by means of the screws located on side panels FIG 6 If the transom is flush with the wall you can fasten the casing frontally by drilling a hole at the front seat on the side panel and fastening the casing by means of the special EV KFCF Kit optional FIG 7 Upon request the standard covering casing can be replaced with a smaller one when the fixture section dimensions prevent the standard casing from closing on the transom The smaller covering casing includes the slot for brush insertion MEM 8 STANDARD COVERING CASING SMALLER COVERIN
9. functional settings please refer to the instructions supplied with the OA PRESENCE T sensor The safety sensor operation test is carried out at the beginning of each door opening and closing cycle Should the sensor fail to properly respond to the test request by the operator control unit the control unit buzzer will beep and the leaf motion speed will be slow throughout the entire stroke 53 26 GONG FUNCTION The GONG function is a entry warning triggered by the activation of the closing safety sensor that is the sensor connected to the E C 1 terminal or to the E C 2 terminal while the automatic door is being crossed To enable the GONG operation set the F39 function to ON on the S12 digital programmer and insert the UR1 module into the J7 OUT3 connector of the LOGIC2 control unit GONG FUNCTION DIAGRAM E Qu LOGIC2 CONTROL UNIT m liid E eI Bab E Waiting time between 2 consecutive door crossing warning GONGS 0096 GONG disabled 0196 immediate 0296 to 10096 1 second to 4 minutes Perform the following operations to activate the GONG function f Use the UR1 module please refer to paragraph 24 and insert it into the J7 OUT 3 connector of the LOGIC2 control unit Select the N O contact between terminals 1 2 of the UR1 module by means of jumper J1 Connect the entry warning buzzer GONG by connecting the power supply to the voltage free contact a
10. paragraph Cyclic function inactive Cyclic function active It activates the continuous door opening and closing cycle it is only used for operation or durability tests 40 PARAMETER TABLE PARAMETER P01 P02 P03 P04 P05 P06 P07 P08 P09 P10 P11 P12 P13 P14 P15 P16 P17 P18 P19 P20 EXPLANATION Opening speed Increasing the value will increase speed during the opening process Closing speed Increasing the value will increase speed during the closing process Reduced opening distance during winter Increasing the value will increase the reduced opening value min 40 cm leaf max 150 cm leaf Motor thrust power At maximum value the maximum motor thrust is obtained Open door pausing time in automatic work programs Setting values range between 0 closing immediately after opening and 20 seconds Open door pausing time in the Night Lock work program Setting values range between 01 closing immediately after opening to 20 seconds When the value is set to 0 default value the function is disabled This parameter allows to set a pausing time in Night Lock mode which exceeds the pausing time set by the P5 parameter Acceleration ramp when opening It sets the leaf acceleration phase during the opening cycle start Increasing the value will increase the leaf starting acceleration during the opening process Acceleration ramp when closing It sets the leaf acceleration ph
11. Accessories aade O Jmm x Jmm Dmm mm requency Of Use losing Speed x Maxf cm s prlea OO UK LTD NBS Specification Premis Euroslide Bi Part sliding door system The Premis System operator can be adapted to the needs of each installation It is prepared for heavy traffic both in large supermarkets hotels airports hospitals and in small and medium buildings offices chemist s restaurants points of sale in general Its most important features are its silent movement when opening and closing dynamic stability and its quick and easy installation All equipment is designed to meet the rigorous safety requirements of BS 7036 1996 and EN16005 installed by Automatic Door Suppliers Association ADSA accredited engineers Standard details for Premis Euroslide Bi Part sliding door system e Supplier ADSF UK LTD e Product reference Premis Euroslide Model e Door configuration Bi parting no fixed panels Bi parting two fixed panels e Drive operation Standard e Door leaf width 700mm 1500mm e Door height 2000mm 3000mm e Finish Anodised silver Polyester powder coated standard BS colours Polyester powder coated standard RAL colours e Glazing As standard Double glazed available on request e Control Digital Selector or Key switch Safety amp security Intelligent self learning movement and presence sensors across door threshold Rear edge presence sensors for
12. DOOR ACQUIRED AAA When acquisition of serial code is completed the display must show the closed padlock symbol on number 1 and the open padlock symbol on the if a single EUROSLIDE operator is connected fig C a nn eni t If the 512 digital programmer is connected to two EUROSLIDE operators to manage two automatic doors instead once serial code acquisition is completed the closed padlock symbol must be displayed on number 1 and on number 2 fig D Press EXIT button to exit Serial communication setups section and enter the general programming menu 14 4 INITIAL SET UP From general programming menu F1 button allows moving forward among menu symbols Select INITIAL SET UP symbol Give a quick pulse to ENTER button to enter the Initial setup section If the 12 digital programmer is connected to two automatic doors select by pressing the F3 button once whether the initial set up concerns the operator of door 1 or that of door 2 A SELECT E el ES OPERATOR Tz AND T H PRESSE SELECT ENE OPERATOR AND THEN PRESSCHK EH TO CONTINUE CONTINUE EXIT 1 OPERATOR 1 OPERATOR 2 The initial set up must be carried out separately on each operator Type the 10 character technical password for access to set up configuration The default technical password supplied by Premis to the S12 digital programmer is A A A A A A A A A
13. INTERLOCK 29 2 INTERLOCK APPLICATION WITH INDEPENDENT INTERNAL DETECTORS 29 3 INTERLOCK APPLICATION WITH A SINGLE INTERNAL DETECTOR 30 CHEMIST S FUNCTION 31 MEANING OF BUZZER WARNING SIGNALS 32 MAINTENANCE PROGRAM DECLARATION OF INCORPORATION OF PARTLY ASSEMBLED MACHINERY UK Premis Slide Operators 22 23 27 28 28 28 28 29 31 31 52 33 34 34 35 38 38 38 38 39 41 43 43 44 44 45 46 46 47 50 51 51 51 52 52 52 53 54 55 56 57 57 58 58 59 60 60 61 GENERAL SAFETY WARNINGS Carefully read this instruction manual for the safe installation and operation of the automatic door Improper installation and incorrect use of the product could cause serious injury Keep the instruction manual for future reference The installer must provide all the information about operation and provide the system user with the user manual delivered with the product MEANING OF THE SYMBOLS USED IN THESE INSTRUCTIONS DANGER Indication of dangerous situations that could cause material damage and personal injury WARNING Identifies the procedures that must be understood and followed to prevent product damage or malfunctions NOTE To point out and place attention on important information GENERAL SAFETY OBLIGATIONS The mechanical and electric installation must be performed by specialised personnel in accordance with current directives and regulations The installer must make sure that the structure to be automate
14. SENSOR FOR AUX2 PRJ38 STOP PHOTOCELL CLOSING E C 2 OPENING E O 2 31 15 BATTERY POWERED EMERGENCY OPENING DEVICE EV BAT1 Insert the battery charger board into connector J1 located on the LOGIC2 control unit see the figure to the side Connect the battery taking care that polarity is correct red cable black cable The battery charger board self checks the battery charge level and displays a green and a red led see table LED SIGNALLING BATTERY 18V 700mAh BATTERY CHARGER Operation The EV BAT 1 device trips in case of mains power failure allowing the EUROSLIDE operator to keep running The battery operating time depends on various factors like the number of operations performed the leaf weight the connected external devices etc The charged battery can supply energy for approximately 10 continuous door opening closing cycles IMPORTANT BATTERY TYPE NiMH 18V 700mAh LED SIGNALLING WARNING SIGNALLED EVENTS Periodically check battery efficiency BATTERY DISCONNECTED ON ON To allow recharging batteries must always be connected to the electronic control unit BATTERY CHARGING BLINKING OF The equipment must be disconnected from the mains when removing BATTERY CHARGED WITH MAINS VOLTAGE OFF BLINKING ON BATTERY DISCHARGED OF BATTERY CHARGED WITHOUT MAINS VOLTAGE the batteries In case of replacement always use genuine batteries Replacement must be p
15. SETTINGS DIP 7 z OFF Output High F11 ON If the safety sensor is installed on E C 1 DIP 8 ON Test input Low F12 ON If the safety sensor is installed on E C 2 DIP 14 OFF Self monitoring enabled F15 ON Closing safety sensor test enabled DIP 3 z ON DIP 4 z OFF Presence detection timer 60 sec F17 OFF LOW level test For information about the adjustments and the other sensor functional settings please refer to the instructions supplied with the OAM DUAL T sensor 52 25 3 OA PRESENCE T SENSORApplication as opening side safety sensor OA PRESENCE T SENSOR WIRING EUROSLIDER OPERATOR LOGIC2 TERMINAL BOARD Correspondence between the sensor cables and the terminal board of the EUROSLIDER operator LOGIC2 control Power supply TERMINAL 17 2 GREEN Power supply TERMINAL 18 3 BLUE Opto NPN sensor 1 safety TERMINAL 13 Opening safety sensor 1 BLUE Opto NPN sensor 2 safety TERMINAL E O 1 Opening safety sensor 2 4 WHIT COM sensor 1 safety TERMINAL 11 COM E WHITE COM sensor 2 safety TERMINAL GND COM 7 BROWN Test TERMINAL 16 TEST 8 ORANGE Test TERMINAL 18 OA PRESENCE T DIP SWITCH SETTINGS S12 PROGRAMMER FUNCTIONAL SETTINGS 102 ON Test input Low F13 ON If the safety sensor is installed on E O 1 F14 ON If the safety sensor is installed on E O 2 F16 ON Opening safety sensor test enabled For information about the adjustments and the other sensor F17 OFF LOW level test
16. Selector Key Switch e Safety amp security Intelligent self learning movement and presence sensors across door threshold Rear edge presence sensors for back of door safety Monitored battery backup provides up to 30 minutes operation in the event of a mains power failure DL OV ac 23U DUHP Power 1 1 8W 12 50 0 lectric Motor losing Speed per leaf Tem Opening Speed 60 cm ause Time 2 Mae O perature ower Supply Of External Accessories 2 052502 5 5 02 ransom Dimension Umm x 150mm 210mmxi20mm ransom Length 500mm _ requency Of Use lt o g Q D D 79 S D a o 3 79 ADS NBS specification Premis Euroslide Telescopic 4 wing sliding door system Especially suitable for small spaces where a reasonable opening width is required and there is insufficient space to install a sliding door leaving the desired gap The two leaf doors are recommendable for shops interior doors in corridors offices etc The four leaf doors provide very wide access and are normally fitted in car showrooms shops hotels etc Standard details for Premis Euroslide Telescopic 4 wing sliding door system Supplier ADSF UK LTD e Product reference Telescopic 4 wing sliding door system e Door configuration Bi Part telescopic slide no fixed panels Bi Part telescopic slide fixed panels e Drive operation Standard e Door leaf width 450mm
17. The door closes back as soon as the opening radars and the closing safety sensors are no longer engaged to minimise the amount of time during which the door stays open To maximise the benefit of this function we recommend that you install single direction activation sensors Setting of the Manual free door program in the EV MSEL mechanical key selector Standard operation of the EV MSEL mechanical selector Manual free door program not enabled Manual free door program enabled when Outgoing only is selected Manual free door program enabled when Night lock is selected Manual free door program enabled when Reduced opening during winter is selected Operation of the OUT4 output with UR1 relay module door status Blinking slowly while the door is opening on when the door is open blinking fast when the door is closing off when the door is closed Operation of the OUT4 output with UR1 relay module alarm warning it activates for two seconds if the internal radar or the closing safety sensor are engaged while the door is closed in Night Lock mode Operation of the OUT3 output with UR1 relay module management of heat blade device generating a flow of cold or heated air to separate the outside temperature from the inside one The output activates when the door opens and deactivates when the door closes Operation of the OUT3 output with UR1 relay module Gong signalling the door is being crossed through Please refer to the Gong function
18. YELLOW COM TERMINAL 7 5 PINK Opto NPN sensor 1 safety TERMINAL 6 E C 1 Closing safety sensor 1 PINK Opto NPN sensor 2 safety TERMINAL E C 2 Closing safety sensor 2 6 BLUE COM sensor 1 safety TERMINAL 7 COM BLUE COM sensor 2 safety TERMINAL GND COM 7 RED Test TERMINAL 16 TEST 8 BLACK Test TERMINAL 18 OA AXIS T DIP SWITCH SETTINGS S12 PROGRAMMER FUNCTIONAL SETTINGS 10 OFF Self testing enabled F11 ON If the safety sensor is installed on E C 1 DIP 11 OFF Output High F12 ON If the safety sensor is installed on E C 2 12 Test input Low F15 ON Closing safety sensor test enabled DIP 3 ON DIP 4 OFF Presence detection timer 60 sec F17 OFF LOW level test For information about the adjustments and the other sensor functional settings please refer to the instructions supplied with the OA AXIS T sensor 25 2 OAM DUAL T SENSOR Application as activation and closing safety sensor OAM DUAL T SENSOR WIRING EUROSLIDER OPERATOR LOGIC2 TERMINAL BOARD EE between the sensor cables and the terminal board of the EUROSLIDER operator LOGIC2 control 1 WHITE Power supply TERMINAL 17 2 BROWN Power supply TERMINAL TERMINAL18 3 GREEN N A a a TERMINAL 8 a E radar or 9 External radar 4 4YELLOW COM ITERMNAL7 COM 7 PINK Opto NPN sensor 2 safety T 7 RED est TERMINAL 16 TEST 8 BLACK Test TERMINAL 18 OAM DUAL T DIP SWITCH SETTINGS S12 PROGRAMMER FUNCTIONAL
19. back of door safety Monitored battery backup provides up to 30 minutes operation in the event of a mains power failure lectric Motor 40Vdc with encoder Opening Speed Max 70 cm s per lea losing Speed 00 2 Working Temperature 15 C 50 Degree of Protection ower Supply Of External Accessories ransom Dimension 0mm x 150mm ransom Length a 500mm requency Of Use vl NE ause Time SES C ADS NBS specification Premis Euroslide Telescopic 2 wing sliding door system Especially suitable for small spaces where a reasonable opening width is required and there is insufficient space to install a sliding door leaving the desired gap The two leaf doors are recommendable for shops interior doors in corridors offices etc The four leaf doors provide very wide access and are normally fitted in car showrooms shops hotels etc Standard details for Premis Euroslide Telescopic 2 wing sliding door system Supplier ADSF UK LTD e Product reference Telescopic 2 wing sliding door system e Door configuration Single telescopic slide no fixed panels Single telescopic slide fixed panels e Drive operation Standard e Door leaf width 450mm 2000mm e Door height 2000mm 3000mm e Finish Anodised silver Polyester powder coated standard BS colours Polyester powder coated standard RAL colours e Glazing As standard Double glazed available on request e Control Digital
20. carry out the system diagnostics and to access the event memory containing information about the automatism and its operation Access to the programming menu is protected by a technical safety password to ensure that only specialised and authorised personnel can perform any operation on the automatism 12 digital programmer can also be used by the final user but only for choosing the operating mode of automatic door the user can also select the preferred language and set up a user password to prevent the use of digital programmer by unauthorized persons Connect the 12 digital programmer to the control unit of the EUROSLIDE operator using a 0 33mm 4 wire cable with twisted pairs for RS485 applications Terminal 13V connect to terminal 1 of the EUROSLIDE control unit 13V Terminal connect to terminal 4 of the EUROSLIDE control unit GND Terminal A connect to terminal 2 of the EUROSLIDE control unit A Terminal B connect to terminal 3 of the EUROSLIDE control unit B For each subject matter described in the following paragraphs the use of digital programmer hereinafter S12 is explained in the specific case A single 12 digital programmer connected to two EUROSLIDE operators can manage the operation of two independent automatic doors Connect in parallel the A B signals of the two operators see the diagram below 12 DIGITAL PROGRAMMER 5 ET 13V ABO yi 111 1
21. damaged if FO7 function OFF or the door opens and remains open if FO7 function ON about to run out 35 The symbol indicates the presence of mains power voltage and the battery if any is e The symbol indicates the absence of mains power voltage and operator activity is In this case the control unit buzzer emits before each door opening for 10 cycles e he symbol without mains power voltage indicates that the emergency battery is Operation of other buttons located on S12 program selector panel REDUCED OPENING DURING WINTER To reduce the passage opening To activate the reduced opening during winter press the button once The symbol on the display indicates that the function is on The reduced opening during winter only operates in bi directional single direction and open door automatic programs To disable the reduced opening during winter press the button once more F2 CHEMIST S OPENING To open the door by a few centimetres To enable the chemist s opening press the F2 button once the F2 symbol appears on the display To disable the chemist s opening press the F2 button once more the F2 symbol goes off on the display F1 Door opening command Press F1 button to open the door but only in bi directional and single direction programs if F32 function OFF Press F1 button to open the door in all operating programs both automatic and night lock if F32 function ON F3 It is o
22. direction for EUROSLIDE operator for single leaf with rightward opening Running direction for EUROSLIDE operator for two mobile leaves with leftward opening E C 1 closing safety sensor input inactive when the safety sensor is not installed on the E C 1 input E C 1 closing safety sensor input active closing safety sensor on E C 1 input installed E C 2 closing safety sensor input inactive when the safety sensor is not installed on the E C 2 input E C 2 closing safety sensor input active closing safety sensor on E C 2 input installed E O 1 opening safety sensor input inactive when the safety sensor is not installed on the E O 1 input E O 1 opening safety sensor input active opening safety sensor on E O 1 input installed E O 2 opening safety sensor input inactive when the opening safety sensor is not installed on the E O 2 input E O 2 opening safety sensor input active opening safety sensor on E O 2 input installed Tests on closing safety sensors E C 1 and E C 2 inactive for sensors which are not pre arranged for the monitoring The function is active if F11 or F12 ON Test on closing safety sensors E C 1 and E C 2 active for sensors pre arranged for automatic door monitoring by the operator cat 2 pl c For further information please refer to the Safety sensors paragraph Tests on opening safety sensors E O 1 and E O 2 inactive for sensors which are not pre arranged for the monitoring The function is active if F13 or F14 ON Test on op
23. door must activate the internal radar of the second door to get door 2 to open e door 2 opens when door 1 has closed back f the person enters through door 2 and it closes back the end of the pause time Operation when the person approaches from the opposite direction is the same Toopen the door even when the other is open the OPEN input control must be operated 29 3 INTERLOCK APPLICATION WITH A SINGLE INTERNAL DETECTOR DOOR 1 DOOR 2 EXTERNAL INTERNAL RADAR N x RADAR l 7 I N amp X v 43 v X ko Z 2 N N AT gt DETECTOR IN COMMON BETWEEN THE TWO DOORS Theuse of asingle internal detector connected in parallel to the Start input ofthe LOGIC2 control units of both door operators is required when the inner distance between the two doors doesn t allow to use two independent radars Setthe F26 function to ON on both door operators Select which ofthe two doors must open first in case of simultaneous command on both F27 door opening 0 5 seconds after the command is issued F27 ON door opening immediately after the command is issued Decide which of the doors must have opening priority and on it set F27 ON on the other door set F27 OFF The interlock operation includes the following steps a the person approaching from the outside activates the external radar of door 1 and door 1 opens b the person enters the inner area between the two doors and engages the internal detector
24. it is a defect on the LOGIC2 control unit You need to turn the main 230V power supply OFF and then ON again after a few seconds If the problem persists it is a defect on the LOGIC2 control unit Check that the leaf slides properly and that there are no obstacles along the path it follows also check that motor and encoder are connected then repeat the set up attempt You need to turn the main 230V power supply OFF and then ON again after a few seconds Check that the motor runs that the motor and encoder connectors are properly plugged in and that the encoder and motor cables are not damaged You need to turn the main 230V power supply OFF and then ON again after a few seconds If the problem persists it is an issue with the LOGIC2 control unit or the encoder Check that the test settings and parameters are correct that the test has also be enabled on the safety sensor and that the electrical connections between sensor and control unit are correct Check that the test settings and parameters are correct that the test has also be enabled on the safety sensor and that the electrical connections between sensor and control unit are correct During operation the battery is constantly monitored Should the system signal any damage to it check that the battery and the battery charger board are working properly You need to turn the main 230V power supply OFF and then ON again after a few seconds If the problem persists it
25. symbol 1 is displayed at the top right 50 24 UR1 MODULE The UR1 module is an optional interface board designed to manage the functions described below It is equipped with a no voltage contact relay output terminals 1 2 that can be of N O or N C type depending on the position of the J1 jumper and of a signal output of OPEN COLLECTOR type 24 1 UR1 module in the OUT3 connector of the LOGIC2 control unit a HEAT BLADE FUNCTION F39 z OFF on the S12 digital programmer Use the no voltage contact on terminals 1 and 2 of the UR1 module to control an air blade which is a device that generates a cold or heated air flow to separate NC the external temperature from the internal temperature The output is active when the door is moving or open whereas it deactivates J1 250 when the door is closed N C contact between b DOOR OPEN WARNING LIGHT terminals 1 2 FUNCTION F39 z OFF on the S12 digital programmer Use the no voltage contact on terminals 1 and 2 of the UR1 module to supply power to a door status warning light NO the output is active when the door is in motion or open while it disables when the J1 door is closed N O contact between c DOOR CROSSING WARNING GONG terminals 1 2 FUNCTION F39 ON Refer to the GONG FUNCTION paragraph for a detailed description of the GONG operation d INTERLOCKING SYSTEM BETWEEN TWO AUTOMATIC DOORS FUNCTION F26 z ON when this function is ON it automatically exclu
26. the electric lock must work normally When the knob is in the released position the electric lock must remain open and free the leaves Cut the exceeding steel cable from the release anchor 21 ELECTRONIC SECTION 77 ELECTRIC ARRANGEMENTS AUTOMATISM POWER SUPPLY DESCRIPTION OF ACCESSORIES CORRESPONDING CABLE 15 Internal movement and presence sensor for door 1 CABLE 8 x 0 5 mm opening and safety during closing 2 Emergency opening button 1 CABLE 2 x 0 5 mm 3 Digital programmer 1 CABLE 4 x 0 33 mm with twisted pairs for RS485 4 External movement and presence sensor for door 1 CABLE 8 x 0 5 mm opening and safety during closing 5 Opening safety sensor 1 CABLE 6 x 0 5 mm Okey button 1 CABLE 2 x 0 5 mm T EUROSLI DE operator 1 CABLE 3 x 1 5 F N T 22 12 ELECTRIC CONNECTIONS H39uVHO A llva 53 P nO 176 LLI Q9 lt lt A tIdININV ISOtid TV LISIG TASG N H3aOON3 aosnoszartavisia UVWOOZ ASL AH3LLVS GIONENOS raiaviss IHNOIS V4 33VSTV4 0019l819313 N HOLIMS SLELILS Alddns H3MOd HOSN3S AL3HVS SNISO TO NOLLVALLOV SNIN3dO HO SHOSNIS AL2HVS NVHOVIG GHVANVIS SNOLLO3NNOO 1V2IH12313 m opi SoJn3 siueJg 23 PART DESCRIPTION LED DL1 40V it displays the presence of 40V
27. voltage at the switching power supply DL2 13V z it displays the presence of the 13V output voltage at terminals 17 18 DL3 E1 DLA E2 z they display the signals coming from the encoder sensor DI5 WD z it displays the proper operation of the main micro controller MP1 by blinking very fast if the led is off or it blinks slowly it indicates an electronic board fault DL8 F3 z it displays the status of photocell FT1 FR3 mod PRJ38 Buzzer z noise signaller MP1 microcontroller A PS1 START button It performs door opening S3 dip switch for operator number selection 1 OFF 2 OFF OPERATOR 1 1 ON 2 OFF OPERATOR 2 only in case a single 12 digital programmer is used to control two automatic doors CONNECTOR J1 Battery charger board connection CONNECTOR J3 Encoder wiring connection e CONNECTOR 44 Motor wiring connection CONNECTOR J5 Electric lock 1 wiring connection LOCK1 CONNECTOR J6 Electric lock 2 wiring connection LOCK2 e CONNECTOR J7 Optional UR1 module connection OUT3 e CONNECTOR J8 Optional UR1 module connection OUT4 ELECTRIC CONNECTION DESCRIPTION On the plastic side panels of the EUROSLIDE operator part 1 in figure in para 3 there is a hole that must be broken open through which the electric cables must be inserted Along the upper part of the aluminium transom there are various fairleads part 8 in the figure in para 3 inside of which the cables should be ru
28. A Press the button in correspondence with letter A asterisk appears on the first letter case on the display repeat this operation for all the other characters reguired If the password typed is correct you enter the section dedicated to set up configuration if the password typed is wrong you return to general programming menu We recommend that you modify the default technical password To this purpose please refer to the Password management paragraph In this section F1 buttons allows selecting the function OFF ON status while Pas OPERATOR TYPE FaN button allows moving to the following function SELECTION Press F2 button to return to previous function on OFF EVOLUS 90 200 UFF Select the operator model i s OFF EUROSLIDE SD HIE REESE aqu rat EE ON EUROSLIDE HD or EUROSLIDE TS Su Select the motion direction OPENING E EUROSLIDE sliding door OFF 2 leaves or 1 leaf opening to the left 50 aC ON 1 leaf opening to the right aM OFF C LERVES 1 1 LEAF D FF UOLUS T um EUROSLIDE telescopic door OFF 4 movable leaves or 2 movable leaves opening to the right RUE m auES g T ON 2 movable leaves opening to the left P LEAVES DPEN 5 v ELECTROLOCE TYPE Select the model of the installed electric lock OFF FAIL SECURE OFF FAIL SECURE or bistable model OR BISTABLE ON SAFE mode ic _ OH F
29. AIL SRFE If the operator is not equipped with an electric lock keep setting to OFF If S03 function is set to OFF only DOUBLE ELEC TRC LOCK Only select ON if a double electric lock for chemist s function is installed in the operator 509 FOR PHARMACY Please refer to the CHEMIST S FUNCTION paragraph FUNCTION 0 92 If no chemist s electric lock is installed keep setting to OFF EHRBLE PREUIOUS FUNCTION MUST BE SET OFF SAFETY SENSOR 1 IN CLOSING s OFF HOT PRESEHT OFF ON USED Select ON only if a safety sensor has been installed on closing on input E C 1 29 Select ON only if a safety sensor has been installed on closing on input E C 2 SRFETY SEHSOR P SOS RURSUS UE NOT PRESENT ON USED 2 SAFETY SENSOR 1 Select ON only if a safety sensor has been installed on opening on input E O 1 IH OPENING PRESENT 3t SAFETY SENSOR 2 Select ON only if a safety sensor has been installed on opening on input E O 2 OPENING HOT PRESENT USED L w TEST SAFETY SENSOR FOR CLOSIHG If S05 and or S06 functions are set to ON only ALIM OFF TEST DISABLE Select ON if the monitored closing safety sensors have been installed as required by standard ON TEST ENABLE EN 16005 to activate sensor test at the beginning of each cycle select OFF only if the closing safety sensors have not been set up to be monitored
30. CHANICAL COMPONENTS OF THE EUROSLIDE SLIDING DOOR OPERATOR 2 TECHNICAL SPECIFICATIONS OF THE EUROSLIDE OPERATOR 90Kg lectric Motor 40Vdc with encoder Opening Speed Max 70 cm s per lea losing Speed Max 60 M Degree of Protection gap Power Supply Of External Accessories Y ogade ransom Dimension omm x 150mm 210mmxi20mm _ Li m ner leaf ause Time Tn C EUHOSLIDE OPERAIOR COMPONENTS side panel pair 6 upper belt coupling 2 electronic control unit lower belt coupling 5 motor assembly with encoder cable gland idle cover links 0 pulley mechanical ouble wheel carriage AU limit switch driving 1 belt 12 5 transom 4 sliding rail 5 casing 16 casing compensating profile 7 rail gasket 5 brush 4 TECHNICAL DATA COMPONENT ARRANGEMENT DOUBLE DOOR LEAF WITHOUT ELECTRIC LOCK E Pp B __ a a LT TRANSOM PL FREE LM LEAF C CONTROL LC BELT LENGTH PASSAGE UNIT LENGTH LT 2PL B 2S 24 PL LT B 2 S 6 345mm LC F M 120 x2 SINGLE LEAF RH WITHOUT ELECTRIC LOCK LT TRANSOM PL FREE LM LEAF WIDTH LM C CONTROL LC BELT LENGTH PASSAGE IDEE PULLEY A UNIT LENGTH LT 2PL B S 24 PL LT B S 2 12 5 LT LM 397 LC F M 120 x2 SINGLE DOOR LH LEAF WITHOUT ELECTRIC LOCK LT TRANSOM PL FREE LM LEAF WIDTH LM C CONTROL LC BELT LENGTH PASSAGE ID LE pur REY
31. For more information refer to Safety sensors paragraph If S07 and or S08 functions are set to ON only Select ON if the monitored opening safety sensors have been installed as required by standard EN 16005 to activate sensor test at the beginning of each cycle select OFF only if the opening safety sensors have not been set up to be monitored For more information refer to Safety sensors paragraph LOGIC STATE SELECTION FOR SENSORS TEST If SO9 and or S10 functions are set to ON only Select test logic status used by operator control unit to monitor safety sensors OH TEST LEVEL HIGH The set up depends on the characteristics of sensor installed If the type of sensors in use is AXIS T OA PRESENCE T select OFF UFF IESI LEVEL LOW For more information refer to Safety sensors paragraph OPEM IHPLIT CONTRCT SELECTION Contact configuration on OPEN input between terminals 5 7 of LOGIC2 board Select ON with normally open contact or when the OPEN input is not used uu aun v Select OFF when using a device with normally closed contact Peli i NORMALLY CLOSED _ 2 INTERLOCK INPUT Configuring the contact on the STOP INTERLOCK input CONTACT SELECTION Select ON with normally open contact or when no device is connected to the input Select OFF when using a device with normally closed contact O FF H U ld NORMALLY OPEN NORMALLY CLOSED The operator
32. G CASING 6 ADJUSTMENT OF THE BELT TENSIONING To adjust belt tensioning slightly loosen the A screw of the idle pulley then screw in to increase belt tensioning or unscrew to decrease belt tensioning the hexagonal screw B After achieving the optimum driving belt tension fully tighten screw A 7 POSITIONING THE MECHANICAL LIMIT SWITCH The mechanical limit switch must be adjusted so that both during opening and closing it stops the carriage stroke before the mobile leaf crashes against any other component It is also used by the electronic control unit to acquire the leaf limit points When adjusting the opening mechanical limit switch take into account that except for the set up manoeuvre and for the first manoeuvre after a power failure at the end of the opening the mobile leaf stops about 5 mm before coming into contact with the limit switch To adjust the limit switch loosen the 3 fastening screws move the limit switch to the desired position then fully tighten the 2 screws again FASTENING SCREWS 8 ANCHORING THE LEAVES TO THE CARRIAGES AND ADJUSTING THEM Undo the two front screws A of every carriage and remove the movable part C Fasten the movable part C you removed to the fixture at the distance indicated in figure 11 if an electric lock is not installed or in figure 12 if the electric lock is installed Now hang the leaf to the automated equipment matching the two carriage parts then
33. INSTALLATI ON MANUAL Technical Help Line Tel 01275 871787 PT ALITOMATIC ENTRANCE SPECIALISTS Sales 01275 871787 Fax 01275 870692 Email info adsf co uk Website www adsf co uk OPremis Euroslide mu wm F2 F3 Design with Quality in mind Q NAVARRA Puertas Automatic Doors UK Premis Slide Operators AUTOMATIC ENTRANCE SPECIALISTS O Premis Euroslide SLIDING DOOR TYPE Euroslide SD 1 Leaf Euroslide SD 2 Leaves Euroslide HD 1 Leaf Euroslide HD 2 Leaves Kg 130 Kg 90 Kg 200 Kg 150 Dimensions 120x150 mm x L max 6500 mm TECHNICAL DATA lectric Motor Opening Speed losing Speed x 00 Maxf cm s prlea ause Time _ 0 Maos ner leaf Se Working Temperature Degree of Protection pn O ower Supply Of External Accessories 0d 0 2 ransom Dimension Jmm x 15Umm Dmm omm ransom Length Su requency Of Use Number of opening cycles 1 000 000 cicli 4 000 cicli giorno tested 1 000 000 Cycle 4 000 Cycles day Safety test Function available for safety sensors with monitoring system Function available to reduce energy consumption in public buildings Interlock system Configuration for automatic doors with interlock system Emergency battery BAT1 Optional It ensures 10 opening cycles in case of emergency Emergency battery BAT2P Optional It ensures continuous opening cycles for 30 minutes Product life time perf
34. INTERLOCK input configuration normally open contact N O Forced closing function inactive Forced closing function active Please refer to the Forced closing function paragraph In case of failure of the closing safety sensor test the door stays open In case of failure of the closing safety sensor test the door closes slowly after 30 seconds The function is active only if the total weight of the closing movable leaves has been set using the P35 parameter single leaf sliding door or telescopic door with two movable leaves The function is active only if the total weight of the closing movable leaves has been set using the P35 parameter double leaf sliding door or telescopic door with four movable leaves Constant pause time Automatic increase of the pause time if the door cannot close due to the high flow of people Interlock function inactive Interlock function active Please refer to the Interlock system paragraph This function is active if F26 ON Door opening is delayed by 0 5 after the issuing of the relevant command Please refer to the Interlock system paragraph This function is active if F26 ON The door opens immediately after the issuing of the relevant command Please refer to the Interlock system paragraph This function is active if F26 ON The opening command is not stored in memory Please refer to the Interlock system paragraph This function is active if F26 ON The opening command is stored in memory Pl
35. ION OF THE MANUAL RELEASE ON THE WALL Identify the fastening point on the wall taking into account that the standard cable sheath is 3 metre long and that it must reach the electric lock CABLE BLOCK CABLE IERMINAL Pass the release cable in the slit in the base and then inside the adjustment register as shown in the figure Then position the cable terminal on the release knob cable block see figure FAS I ENING SCREW BLACK BANDS N FASTENING SCREW Drill the wall and fasten the base of the release mechanism using the fastening screws Apply the adhesive label as shown in the figure taking the four black bands on the label as a reference which must be positioned in correspondence of the 4 cardinal points Insert the adjustment register using 2 nuts one in the plastic slot and the other outside of it LOWER SCREW CABLE ERMINAL Now insert the release knob on the base of the mechanism being careful to keep the cable terminal in the seat of the cable block and the knob in the correct position When inserting the knob the cable terminal must be in the position just beyond the lower fastening screw in a clockwise direction Once the knob is inserted fasten the closing screw insert the sheath and turn the knob to the RELEASED position In this position only the orange part of the label must be seen with the drawn black arrows Make sure that the system is operating by turning the knob clockwise and ke
36. It is prepared for heavy traffic both in large supermarkets hotels airports hospitals and in small and medium buildings offices chemist s restaurants points of sale in general Its most important features are its silent movement when opening and closing dynamic stability and its quick and easy installation All equipment is designed to meet the rigorous safety requirements of BS 7036 1996 and EN16005 installed by Automatic Door Suppliers Association ADSA accredited engineers Standard details for Premis Euroslide single sliding door system e Supplier ADSF UK LTD e Product reference Premis Euroslide Model e Door configuration Single sliding no fixed panel Single sliding one fixed panel e Drive operation Standard e Doorleaf width 700mm 3000mm e Door height 2000mm 3000mm e Finish Anodised silver Polyester powder coated standard BS colours Polyester powder coated standard RAL colours e Glazing As standard Double glazed available on request e Control Digital Selector or Key switch e Safety amp security Intelligent self learning movement and presence sensors across door threshold Rear edge presence sensors for back of door safety Monitored battery backup provides up to 30 minutes operation in the event of a mains power failure 90Kg lectric Motor 40Vdc with encoder Max 70 cm s per leaf Max 6 PauseTime Max20Sc _ 1 1 Degree of Protection Power Supply Of External
37. MINAL BOARD 4 Inputs 11 12 13 14 15 11 Input COMMON 12 auxiliary AUX 1 N O contact serving for three functions depending on the configuration set on the control board a Using the mechanical key selector EV MSEL for the selection of the door work program 01 connect terminal 12 to terminal 3 of the mechanical selector b If S12 digital programmer is present the activation of the AUX 1 input causes the door to close and the Night lock function to activate by passing S12 digital programmer setting c If INTERLOCK operation is activated between two Premis automatic doors F26 ON the activation of the AUX1 input by passes the interlock function see the Interlock system paragraph 13 z input of the Safety side sensor for opening E O 1 N C contact The operation of safety sensor for opening E O 1 must be enabled by 12 digital programmer function F13 ON The door opens at slow speed if the sensor detects an obstacle during opening if F19 OFF The door stops if the sensor detects an obstacle during opening if F19 ON 14 STOP INTERLOCK input Input contact logic state can be selected as N O or N C by 12 digital programmer function F21 The input can be used for three different purposes according to the configuration set on the control unit a Stop command to stop door motion b detection of the interlock signal to prevent the door from opening when the interlock function is enab
38. O RECEIVER 1 GENERAL INFORMATION The EN RF1 single channel receiver is a 433 92 MHz radio receiver designed to open the Euroslider automatic door using the SPYCO transmitters manufactured by Premis 2 USE The EN RF1 receiver must be coupled to the J9 connector of the LOGIC2 electronic control unit and it is prearranged to control the opening of the automatic door in all the automation work programs The automatic door opening control is given by the SPYCO radio control while the protection and safety of the door movement are ensured by devices outside the receiver itself It shall never be used in any case where the door activation or deactivation may cause injuries and damage Class receiver in compliance with the ETSI EN 300 220 1 V 2 1 1 2006 04 standards chapter 4 1 1 3 INSTALLATION OF THE RECEIVER Couple the EN RF 1 receiver fig 1 to the J9 connector of the electronic control unit LOGIC2 fig 2 Proceed with saving the SPYCO radio controls fig 3 as follows a Enter the programming mode of the SPYCO transmitters pressing and holding the SW1 button until the L1 led is steadily lit approx seconds b Press the button of the SPYCO transmitter to be saved and the successful saving will be indicated by 5 fast flashings of the L1 led c Afterwards the L1 led will be steadily lit again and it will be possible to save another transmitter by repeating the described operation from step b and so on with all the transmitters
39. ON door opening immediately after the command is issued Decide which of the doors must have opening priority and on it set F27 ON on the other door set F27 OFF E EXTERNAL Choose if you want or don t want to store in memory the opening command on the internal radar of the second door while the first door is still moving F28 OFF opening command storage disabled To open the second door the radar must be activated when the first door has closed back F28 ON opening command storage enabled To open the second door the radar can be activated even when the first door is still moving the second one will open automatically as soon as the first one has completed the closing procedure If you wish the second door to open automatically after a preset time if its radar is detecting a presence even though the first door has not closed back yet setthe P22 parameters P22 0 the function is disabled and the second door opens only after the first one has closed back P22 01 second door opens 10 seconds after the opening of the first one if its radar is engaged P22 100 the second door opens 2 minutes after the opening of the first one if its radar is engaged The interlock operation includes the following steps a the person approaching from the outside activates the external radar of door 1 and door 1 opens b thepersonenters the internal area between the two doors C door closes back after the pause time d the
40. V MSEL to terminal 12 AUX 1 of EUROSLIDER operator control unit Terminal 4 of EV MSEL to terminal 15 AUX 2 of EUROSLIDER operator control unit For any check on proper connection and operation of key mechanical selector enter inputs diagnostics see par 14 6 to ensure that different key positions correspond to activation of the following symbols 4 ir Mu 7 7 BJ 5 no active symbol OPERATING MODE Insert and rotate the key in EV MSEL selector to select the program desired Open door program The door stops in complete opening position Reduced opening program during winter To open the door partially Bi directional automatic program The door automatically opens when each opening control activates Single direction automatic program output only To exclude the incoming detection on external radar input Night lock program The door can only be open by OPEN input or radio control if EN RF1 radio receiver is installed The key can be taken out of the selector when in any position in order to prevent the work program from undesired changes 3 gt MANUAL FREE DOOR PROGRAM The manual free door program can be selected by means of the EV MSEL selector to disable the automatic door automatic operation and to let the operator manually move the leaves To enable the MANUAL FREE DOOR program in the desired position of the EV MSEL mechanical selector operate on the F36 F37 function com
41. already started up before 5 BEEPS Encoder disconnected or not working Motor disconnected or not working 1 BEEP before the opening Failed opening safety sensor test 1 BEEP before the opening Battery failure or low battery charge warning 2 BEEPS when the door is open Failed closing safety sensor test 1 prolonged BEEP 1 Detection of an internal system failure 32 MAINTENANCE PROGRAM To ensure that the automatic door keeps running safely along time we recommend to carry out the maintenance operations once every 6 months The installer can set the number of opening closing cycles after which the SCHEDULED MAINTENANCE message will appear on the display of the 12 digital programmer P33 parameter Warning Before performing any operation on the automated equipment cut off the mains power supply Check that all screws are tight Check the belt s tension Clean the carriage sliding rail and the ground sliding guide Check that carriages and leaves are properly aligned and that the door s final ledge is in correct position Check that the electric lock if any is properly fastened and that the mechanical release device operates properly Check connections and electric cables Check leaf stability and make sure that they move smoothly and frictionless along the whole stroke Check that motion speeds involved forces and installed safety devices are working appropriately
42. ase during the closing cycle start Increasing the value will increase the leaf starting acceleration during the closing process Braking ramp when opening It sets the leaf deceleration phase at the end of the opening cycle Increase the value for quicker braking at the end of the opening process Braking ramp when closing It sets the leaf deceleration phase at the end of the closing cycle Increase the value for quicker braking at the end of the closing process Deceleration starting distance when opening Increasing the value will increase the distance from the end of the stroke during opening at which the leaf proceeds at slow speed until the end of the stroke Deceleration starting distance when closing Increasing the value will increase the distance from the end of the stroke during closing at which the leaf proceeds at slow speed until the end of the stroke Motor thrust power at the end of the closing cycle It sets the thrust power in the last phase of the closing cycle this allows the leaf to more easily close on the final ledge Increasing the value will increase the thrust power Motor thrust time at the end of the closing cycle It sets the thrust duration in the last phase of the closing cycle this allows the leaf to more easily close on the final ledge Increasing the value will prolong the thrust time Tension keeping the door closed It sets the tension the motor exerts when the door is closed to keep the leaves properly in co
43. bination on the 12 digital programmer see para FUNCTION SETTING 34 17 2 812 DIGITAL PROGRAMMER USED AS PROGRAM SELECTOR 12 digital programmer can be installed in the system and used by the user like a program selector as an alternative to manual and EV MSEL mechanical selector if you need a more complete tools in terms of functions and graphs To enable 12 operation like a program selector set up 01 function OFF see Functions setup paragraph me eom m Om By pulse pressing the button choose the automatic door operating mode Each time a button is pressed it switches from a work program to the next one The operating programs to be selected by button are described below Bi directional automatic program The door automatically opens when each opening control activates Single direction automatic program output only To exclude the incoming detection on external radar input Single direction automatic program input only To exclude the outgoing detection on internal radar input Open door program The door stops in complete opening position Night lock program The door can only be open by OPEN input or radio control if EN RF1 radio receiver is installed Free manual door The automatic operation is disabled and door can be manually open Power warning light display operating ensured by emergency battery if any which is in working order e he symbol with mains power voltage indicates that the battery is
44. bling time will be of 120 seconds OPENING DISTANCE IN CHEMIST S MODE Increasing the value will increase the reduced opening value in chemist s mode min setting 5cm leaf max 20cm leaf Unused parameter Unused parameter Unused parameter Unused parameter Unused parameter Unused parameter Unused parameter Unused parameter Unused parameter Scheduled maintenance This parameter allows to select the number of opening closing cycles after which the SCHEDULED MAINTENANCE message appears on the display of the 12 program selector When the parameter is set to OFF default value the message is not displayed Select the number of cycles according to the door operation and to the usage conditions 8K 8000 cycles 16K 16000 cycles 32K 32000 cycles 64K 64000 cycles 128K 128000 cycles 256K 256000 cycles 512K 512000 cycles Setting of the movable leaf total weight to avoid exceeding the impact force limits during opening EN16005 and DIN18650 When selecting the value of the movable leaf total weight the door opening speed will be automatically adjusted by the operator to avoid exceeding the impact force limits during opening provided for by the EN16005 and DIN18650 standards When the value is set to 00 Kg the function is disabled and the opening speed can be set using the P01 potentiometer in this case the installer must take other safety measures in compliance with the regulations in force The setting
45. ches back to the PASSWORD MANAGEMENT section press the EXIT button to return to the general programming menu e fthe typed password doesn t match the previous one the PASSWORD ERROR message appears on the display the system will switch back to the PASSWORD MANAGEMENT section and the user will have to repeat the procedure 21 3 HOW TO CHANGE THE SERVICE PASSWORD e Select SERVICE PASSWORD e Press OK F1 button C CURRENT PASSWORD PASSWORD Type the primary password m ws EXIT Type the new service password selecting a combination of 5 characters from the letters A B C D REPEAT NEW PASSWORD e 115 required to repeat the new password so type the previous combination again e f the password typed is correct PASSWORD OK is shown on display for one second and the system returns to the PASSWORD MANAGEMENT section Press the EXIT button to return to general programming menu If the typed password doesn t match the previous one the PASSWORD ERROR message appears on the display the system will switch back to the PASSWORD MANAGEMENT section and the user will have to repeat the procedure 45 21 4 ENABLING USER PASSWORD USAGE primary and service e Select PASSWORD ON OFF Press OK F1 button CURREHT PASSWORD PASSWORD e Type the primary password EXIT B ON PASSIJORD ON PASSWORD OFF on Exit OFF e Press the ON D button
46. d in the table LOGIC2 OPERATOR 1 OF LOGIC2 OPERATOR oo Follow chapter 14 1 only if S12digital programmer is new and powered for the first time Follow chapter 14 2 if digital programmer has already been used before 14 1 FIRST START OF S12 DIGITAL PROGRAMMER Power the EUROSLIDE operator by mains voltage the control unit buzzer emits some quick LAN T ITALIANO short beeps IGLISH Language selection is shown on the display of S12 digital programmer use the F2 and buttons to move arrow to the desired language Press EXIT button to exit Language section and enter Serial communication setups section as under 14 3 14 2 USE OF 12 DIGITAL PROGRAMMER Power the EUROSLIDE operator by mains voltage the control unit buzzer emits some quick short beeps The display signals the lack of communication between 12 and operator control units since the serial code of LOGIC2 logic board is not stored on N DSEL Press button for about 5 seconds to enter the general programming menu The F1 button allows to move forward among the menu symbols Select RS485 symbol Give a quick pulse to ENTER to enter the Serial communication setups section as described under para 14 3 14 3 SERIAL COMMUNICATION SETTINGS 12 programmer automatically detects the presence of operator electronic control unit fig A and stores the board serial code LOGIC2 fig B AUTOMATIC
47. d is stable and robust and if necessary make it this way by making structural modifications Keep product and packaging materials out of children s reach as they might be a source of danger Do not let the children stay or play within the range of the door This product was designed and built exclusively for the purpose described in this documentation Any other use that is not specifically indicated could adversely impact the condition of the product and the safety of people ADSF UK accepts no responsibility for incorrect product installation and usage as well as for any damages caused by changes made without its prior consent ADSF UK is not responsible for the construction of the fixtures to be motorised The IP22 degree of protection requires that the operator is installed only on the inner side of buildings This product cannot be installed in explosive environments or atmospheres or in the presence of flammable gases or fumes Make sure that the characteristics of the electric distribution network are compatible with the technical data indicated in this manual and that upstream of the system there is an omnipolar switch with an opening distance of the contacts of at least 3mm and a residual current device Connect the ground conduit of the electric system The automatic door must be checked started up and tested by skilled and well prepared personnel A technical dossier must be prepared for every automation as required by the Machine Di
48. des the other functions associated with F39 Refer to paragraph 21 INTERLOCK SYSTEM for a detailed description of the 24 2 UR1 module in the OUTA connector of the LOGIC2 control unit a SIGNALLING OF THE AUTOMATIC DOOR OPERATION DOOR STATUS FUNCTION F38 z OFF on the S12 digital programmer Use the no voltage contact on terminals 1 and 2 of the UR1 module to activate a door status warning light OPENING MOVEMENT SLOW FLASHING DOOR OPEN FIXED LIGHT ON CLOSING MOVEMENT FAST FLASHING DOOR CLOSED LIGHT OFF b ALARM WARNING FUNCTION F38 ON The output contact of the UR1 module activates for two seconds if in the NIGHT LOCK work program the INTERNAL RADAR or CLOSING SAFETY SENSOR inputs activate when the door is closed 51 25 SAFETY SENSORS This paragraph describes the procedure to be followed to properly connect and set up some of the safety sensors available on the market and complying with the EN12978 standard to ensure a safety level which complies with PL c Cat 2 as provided for by the EN16005 standard 25 1 OA AXIS T SENSOR Application as activation and closing safety sensor OA AXIS T SENSOR WIRING EUROSLIDER OPERATOR LOGIC2 TERMINAL BOARD Correspondence between the sensor cables and the terminal board of the EUROSLIDER operator LOGIC2 control 1 WHITE Power supply TERMINAL 17 2 BROWN Power supply TERMINAL 18 3 GREEN N A activation TERMINAL 8 Internal radar or 9 External radar 4
49. e transom L1 and L2 every 600mm The figure shows the fastening dimensions When drilling the transom and the wall take care not to damage the sliding rail B1 as that would affect the operation and the noiselessness of the automated equipment After fastening the transom thoroughly clean the sliding area from any drilling scraps SECTION WITH COMMERCIAL PROFILES SECTION WITH POLISHED EDGE ATTACHMENT 41 5 DIMENSIONAL TABLE FOR EUROSLIDE SD AND HD OPERATORS LEGEND PL FREE PASSAGE LT AUTOMATION LENGTH LM z LEAF WIDTH PASSAGE OPENING HEIGHT 1 MOBILE LEAF 2 MOBILE LEAVES S PL II Tr n T n z LT LT Dimensioning mm Dimensioning mm LM leaf Sz overlapping PL nominal LM leaf Sz overlapping PL nominal Liz automation B contact with passage LT automation B contact with passage length S 50 B 10 opening length S 50 B 10 opening LT 2PL B S 24 LM LT B S PL LT B S 12 LT 2PL Bi28 94 21 8 8 6 PL ITB S 6 2 2000 1008 968 2000 9 949 2500 1258 1218 2500 1199 3000 1508 1468 3000 5 1449 3500 1758 1718 3500 1699 4000 2008 1968 4000 s9 1949 4500 2258 2218 4500 RD 2199 5000 2508 2468 5000 2449 5500 2758 2718 5500 5 2699 6000 3008 2968 6000 29 2949 6500 3258 3218 6500 9 3199 70 SLIM ELECTRIC LOCK 70 7 GENERAL DESCRIPTION The EUROSLIDE automation electric lock is available in 3 models which have different behavi
50. ease refer to the Interlock system paragraph Operation with automatic closing Step by step function a START or OPEN input command opens the door a second command is required to close back the door Push amp Go function inactive Push amp Go function active Manually moving the leaf by a few centimetres in the opening direction activates an automatic opening cycle The internal and external radars are not active during the closing operation in the work program Night Lock The internal and external radars are active during the closing operation in the Night Lock work program causing the door to reopen The F1 button of the 12 digital programmer controls door opening in automatic programs only The F1 button of the 12 digital programmer controls door opening both in automatic programs and in night lock mode It enables the warning beep by the buzzer when the motor thrust power limit is reached Please refer to the Functional testing paragraph Please refer to the Functional testing paragraph It disables the warning beep by the buzzer when the motor thrust power limit is reached Switching from reduced opening during winter to full opening inactive Switching from reduced opening during winter to full opening active If the door cannot close due to the high flow of people after approximately one minute it switches from reduced opening to full opening Energy saving function inactive Energy saving function active
51. ening safety sensors E O 1 and E O 2 active for sensors pre arranged for automatic door monitoring by the operator cat 2 pl c For further information please refer to the Safety sensors paragraph The function is active if F15 or F16 ON Safety sensor test with logic level LOW For information please refer to the Safety sensors paragraph The function is active if F15 or F16 ON Safety sensor test with logic level HIGH For information please refer to the Safety sensors paragraph PRJ38 FT1 FR3 photocell not installed PRJ38 FT1 FR3 photocell installed and working as a stop sensor in the panic exit breakout system The activation of the safety sensor during opening slows down the leaf opening motion until the end of the stroke is reached The activation of the safety sensor during opening stops the leaf motion until the obstacle is removed OPEN input configuration normally closed contact When a device with N C contact is installed OPEN input configuration normally open contact When not in use or if a device with N O contact is installed 39 FUNCTION STATUS OFF F21 ON OFF F22 ON OFF F23 ON OFF F24 ON OFF F25 ON Eat OFF ON OFF F27 ON OFF F28 Sn OFF F29 ON OFF F30 ai OFF F31 ahi OFF F32 ON OFF F33 ON OFF F34 ON OFF F35 ai F36 F37 OFF OFF ON OFF OFF ON ON ON OFF F38 ON OFF F39 ON OFF F40 ON EXPLANATION STOP INTERLOCK input configuration normally closed contact N C STOP
52. ensured by the application of one of the following vsa methods e Use of protection devices sensors complying with standard EN12978 SLIDING DOOR HAZARDOUS AREA e LOW ENERGY motion It is essential to be aware that when most users are old ill disabled people and children any contact of the door with the user is not acceptable Any residual risks must be properly signalled A Main closing edge B Secondary closing edge 4 1 MODEL DESCRIPTION The Euroslide operator has been designed and manufactured for the control of pedestrian automatic sliding doors A list of the operator models for Euroslide sliding doors produced by Premis is provided below e Euroslide SD Operator for single leaf max weight 130Kg or double leaf max weight 90Kg leaf doors 40Vdc 80W motor e Euroslide HD Operator for single leaf max weight 200Kg or double leaf max weight 150Kg leaf doors 40Vdc 130W motor Euroslide TS Operator for telescopic doors equipped with 2 movable leaves max weight 150Kg leaf or 4 movable leaves max weight 75Kg leaf 40Vdc 130W motor The choice of the model depends on the weight of the leaves and on the type of door to be automated single or double leaf sliding door or telescopic door equipped with two or four movable leaves All EUROSLIDE operator models can be equipped with the battery for emergency opening and with the electric block The operator must be installed in indoor environments ME
53. eping the cable taut with your hand WARNING THE KNOB TURNS MAX 45 50 DEGREES AND AT THE END THERE ARE CLICKS IN ORDER TO MAINTAIN THE POSITION AFTER THE RELEASE Apply the provided screw cover label as shown in the figure and return the knob to the RELEASED position 10 5 INSTALLATION OF THE MANUAL RELEASE OVER THE TRANSOM 20 Put the drilling template into place aligning it with the reference marks at the top of the EUROSLIDE transom Align the template with the centre of the solenoid axis Drill a hole into the transom as indicated on the template Fix the release knob bottom using the supplied screws Insert the 250mm sheath Apply the adhesive label as shown in the figure taking the four black bands on the label as a reference which must be positioned in correspondence of the 4 cardinal points Insert the steel cable terminal into the release knob as shown in the figure and fasten the knob to the base with the special screw SCREW COVER LABEL Apply the screw cover label on the fastening screw By moving the release knob to the RELEASED position only the orange part of the label must be seen with the drawn black arrows Insert the compression spring and insert the metal cable inside the special release anchor then lock it with the screw clamp Adjust the cable tension so to give the spring a light pre load Check that the manual release works when the knob is in the locked position
54. er end of the cable has a connection that is inserted in the LOCK1 connector on the Euroslide operator electronic control unit If the bistable electric lock EV EBSBIS is installed there will be a second power cable One end of it must be connected to the secondary solenoid cables LOCK2 of the electric lock and the other end must be connected to the LOCK 2 output on the electronic control unit where the connector is located 14 10 3 MANUAL RELEASE The Fail Secure EV EBSFSE and Bistable EV EBSBIS models are equipped with the EV EBSSMA manual release system that is used to release the electric lock in the case of a power failure and therefore move the leaves freely 2 RELEASE KNOB FASTENING For the fastening on both the right and left side of the automation A you need to fix the adjustment register on the bottom of the release knob Insert the steel cable inside the flexible sheath as shown in the figure Fix the bottom of the release knob to the side panel using the supplied self threading screws on the two hole existing in the side panel T5 Apply the adhesive label as shown in the figure taking the four black bands on the label as a reference which must be positioned in correspondence of the 4 cardinal points Insert the steel cable terminal into the release knob as shown in the figure and fasten the knob to the base with the special screw Apply the screw cover label on the fastening
55. er which the door opens since the issuing of the opening command and the activation of the electric lock When the parameter is set to the minimum value i e 0 the leafstarts as soon as the electric lock is activated when it is set to 100 the delay will be of5 seconds 41 PARAMETER P21 P22 P23 P24 P25 P26 P27 P28 P29 P30 P31 P32 P33 P34 P35 EXPLANATION Internal Radar and Start enabling time when the Night Lock work program is selected Time during which the Internal Radar and Start inputs remain enabled to open the door after the Night Lock work program has been set At 0 the function is disabled at 0196 time 10 seconds at 10096 time 120 seconds Time after which the interlock between two automatic doors gets disabled if the open door doesn t close back setting is enabled if F26 ON Please refer to the Interlock system paragraph When the parameter is set to 0 the default value the function is disabled Time after which the interlock gets automatically disabled if the currently open door doesn t close back due to the high flow of people In this case if the internal radar of the second door is activated by the people who are in the gap between the two doors the second door opens allowing people to move out At 0196 the interlock disabling time and the second door opening time will be of 10 seconds At 50 the interlock disabling time will be of 60 seconds at 100 the interlock disa
56. erformed by qualified personnel Remove batteries from the equipment before its disposal Batteries contain polluting substances therefore they must be disposed of in accordance with the provisions of local regulations 32 16 BATTERY POWERED EMERGENCY OPENING DEVICE EV BAT2P Battery unit location inside the EUROSLIDE operator Depending on the space available inside the EUROSLIDE operator the battery unit can be installed on the right side of the transom next to the electronic control unit casing Solution 1 or to the left of the gearmotor Solution 2 Solution 1 Side view screw in through the front slot of the plate Solution 2 Front view Side view screw in through the rear slot of the plate EE III eee LS II II E Insert the battery charger board into connector J1 located on the LOGIC2 electronic control unit see figure 1 Connect the battery taking care that polarity is correct red cable black cable OPERATION The EV BAT2P device trips in case of mains power failure allowing the EUROSLIDER operator to keep running The battery operating time depends on various factors on the number of operations performed on the leaf weight on the connected external devices etc Indicatively the charged battery can supply energy for about 30 continuous door opening closing cycles or for approximately two hours if the door isn t operated WARNING IMPORTANT
57. f f Atthis point it is possible to save again the code of the transmitters to be used following the procedure described in paragraph 3 6 TECHNICAL SPECIFICATIONS Power supply 12Vdc Absorption 10mA stand by 50mA in operation Outputs OPEN COLLECTOR Frequency 433 92 Mhz Memory capacity 250 users Range without obstacles 30 meters Operating temperature 20 55 Receiver class ETSI EN 300 220 1 Chapter 4 1 1 Class 3 7 DECLARATIONS Marketing sale and use are valid without restrictions in all EU countries With this document Premis SpA declares that the EN RF1 receiver complies with all the essential requirements and with all other relevant dispositions established by 1999 5 EC directive The declaration of conformity is annexed to the EN RF1 receiver instructions 55 LED MEANING FIG 1 LED OFF LED ON LED BLINKING SLOW full memory or transmitter already saved LED BLINKING FAST transmitter saving LED BLINKING VERY FAST memory deletion 28 FORCED CLOSING FUNCTION To enable the Forced closing operation set the F22 function to ON When a N C contact is connected to the Stop Interlock input terminals 11 14 it allows to forcibly close the door at slow speed after the device activation During this closing operation all control and safety inputs are disabled Should the forced closing device still be active once the door is closed the only way to open the door will be using a held c
58. he obstacle To set up the available functions refer to Functions setup paragraph To adjust the variable parameters refer to Adjustment of parameters section REPEATING THE INITIAL SET UP Set up operation must be repeated if one of the following conditions varies leaf weight leaf stroke opening direction type of electric lock replacement of the LOGIC2 board 14 6 INPUT DIAGNOSTICS 12 programmer allows checking the inputs status to ensure proper operation of all devices connected with EUROSLIDE operator To enter Inputs diagnostics while the automatic door operating program is shown on display keep F2 button pressed for about 3 seconds The F3 button is only used in case the 12 programmer is connected to two EUROSLIDE operators and the symbol 1 is displayed at the top right if the inputs on operator 1 are being viewed or 2 if the viewed inputs are those of operator 2 Press F3 once to switch from 1 to 2 and vice versa If the 12 programmer only manages a single operator the symbol 1 is displayed at the top right The display shows the symbols of all operator inputs with the relevant terminal number If an input is used the corresponding symbol lights up with an arrow on a side ETF SAFETY SAFETY SENSOR FOR SENSOR FOR CLOSING E C 1 OPENING E O 1 INTERNAL RADAR EXTERNA RADAR STOP INTERLOCK EN RF1 RECEIVER activated by the SPYCO radio control SAFETY SAFETY SENSOR FOR AUX 1
59. ight Lock work program Bank function the electric lock activates when the door is closed in all work programs Electric lock type selection FAIL SECURE EV EBSFSE or BISTABLE EV EBSBIS Electric lock type selection FAIL SAFE EV EBSFSA Electric lock for chemist s function not installed Double electric lock for chemist s function active Electric lock not active when the door is closed in the OUTGOING ONLY work program Electric lock active when the door is closed in the OUTGOING ONLY work program Operation when powered by battery if the mains power supply is off the door keeps working normally Operation when powered by battery if the mains power supply is off the door opens and stays open in the automatic work programs Battery monitoring if the battery is low or damaged the control unit buzzer beeps before the door opens for ten cycles Battery monitoring if the battery is low or damaged the door opens and stays open in automatic programs Operation without mains power supply with battery getting depleted the door works normally Operation without mains power supply with battery getting depleted the door opens and stays open Operator type selection EUROSLIDE SD Operator type selection EUROSLIDE HD or EUROSLIDE TS Running direction for EUROSLIDE operator for double leaf and single leaf with leftward opening Running direction for EUROSLIDE operator for four mobile leaves or two mobile leaves with rightward opening Running
60. in common between the two doors C door 1 closes back after the pause time detection on the Start input of door 1 is disabled during the pause time throughout the closing procedure and for 5 seconds after the door has closed d door2 opens when door 1 has closed back if the internal detector on the Start inputis active e the person enters through door 2 and it closes back atthe end ofthe pause time Operation when the person approaches from the opposite direction is the same To open the door even when the other is open the OPEN input control must be operated 58 30 CHEMIST S FUNCTION On the Euoslide operator you can install a dedicated second electric lock for the chemist s opening it is an electric lock version specially designed for the chemist s function This type of electric lock must be connected to the LOCK 2 output J6 connector of the LOGIC2 control unit and only works if the control unit is configured with the function set to ON Fail secure type electric lock and with the F04 function set to ON chemist s function enabled The figure below shows the location of the two electric locks inside the Euroslide operator the chemist s electric lock kit includes the installation instructions NORMAL LOCK STAINLESS STEEL PLATE FAIL SECURE LOCK1 PHARMACY LOCK2 PHARMACY LOCK STAINLESS STEEL PLATE To activate the chemist s function you must press the F2 button on the digital programmer 12 from the mai
61. is an issue with the LOGIC2 control unit You need to turn the main 230V power supply OFF and then ON again after a few seconds If the problem persists it is a defect on the LOGIC2 control unit The system restores automatically after a few seconds If the problem persists it is an issue with the LOGIC2 control unit 23 MAINTENANCE To enter type the 10 character technical password for more information refer to Password management paragraph RESET ERRORS RESET PARTIAL COUNTER This section is only accessed to reset any error existing in the event memory and the partial counter of the door opening closing cycles The event memory and partial counter reset must be performed by specialized personnel only during routine maintenance after performing all system operation checks The buttons in this section are used as follows The v button allows to move forward in the reset type selection The F2 button allows to return to the previous reset F1 OK button allows to confirm data resetting for the selected reset type The F3 button is only used if the S12 digital programmer is connected to two operators for the management of two automatic doors and the symbol in the top right section of the display indicates 1 if the reset operations refer to operator 1 or 2 if they refer to operator 2 Every touch on F3 button allows to switch from 1 to 2 and vice versa If the S12 programmer only manages a single operator the
62. is ready for the set up cycle OPERATOR READY Press the button OK TO SET UP The control unit buzzer emits 4 beeps and starts the set up cycle PRESS 0K TO START The door starts closing until it is fully closed then it performs an opening closing cycle at slow 3 SECONDS SOUND speed which it will necessarily have to complete At the end of the cycle a prolonged BEEP signal zal SIGNAL MEAN SET UP COMPLETED that set up is over 30 14 5 FUNCTIONAL TESTING Select door automatic operation by program selector Once the set up is completed the default program selector is the S12 digital programmer function F01 OFF If the EV MSEL mechanical selector is installed set function F01 ON please refer to paragraph 19 1 Function setting Refer to Program selectors paragraph describing the two types of selector provided for to select the automatic door operating mode To start an opening manoeuvre give a pulse to PS1 button Start on the LOGIC2 board or engage the door opening devices Ensure that door opening and closing cycle is properly performed and that pulse organs and safety sensors operate to adjust sensor detection field refer to the instructions delivered with the sensor The safety sensors must ensure that the leaf doesn t impact against any automatic door users please comply with the provisions contained in the regulations in force During door movement intermittent signals could be heard as e
63. le signal brown cable e TERMINAL BOARD M8 S12 digital programmer 1 Power supply positive 13V 2 Communication signal A 3 Communication signal B 4 Power supply negative GND PRJ38 PHOTOCELLS The pair of PRJ38 Premis photocells consists of a transmitting and a receiving capsule The transmitting capsule besides is equipped with a 2 wire cable bearing the PRJ38 TX mark while the receiving capsule has a 3 wire cable bearing the PRJ38 RX mark Drill an 11 5 mm hole to fasten the capsules into the fixture To avoid any interference due to exposure to direct sunlight we recommend that you install the receiving capsules on the side that is best protected against Photocell operation mode The PRJ38 photocell is used as a STOP sensor in the panic exit breakout system To ensure proper operation the photocells must be perfectly aligned and at the same height The PRJ38 photocell must be enabled by the 12 digital programmer function F18 ON The activation of the PRJ38 photocell stops the door motion and the control unit buzzer beeps 4 times Interrupting the photocell infrared beam will cause the F3 led to light up DL8 26 M7 12 DIGITAL PROGRAMMER RECEIVING TRANSMITTING 13 12 DIGITAL PROGRAMMER SCOPE and CONNECTIONS The 12 digital programmer is the essential tool for the installer to configure the automatic door operation and perform the set up and function parameter setting operations to
64. led function F26 ON In this case the input must be configured as N C C connection of a door closing device allowing to forcibly close the door when function F22 is set to ON In this case the input must be configured as N C 15 z auxiliary AUX 2 N O Contact serving for two functions depending on the configuration set on the control board a Using the mechanical key selector EV MSEL for the selection of the door work program F01 ON connect terminal 15 to terminal 4 of the mechanical selector b It can be used as a door opening command in all automatic door work programs e TERMINAL BOARD 5 Inputs 5 6 7 8 9 10 5 zinput OPEN Input contact logic state can be selected as N O or N C by 12 digital programmer function F20 The activation allows opening the door of all operating programs 6 input of the safety side SENSOR for closing E C 1 N C contact The operation of safety sensor for closing must be enabled by 12 digital programmer function F11 ON If during closing it detects the presence of an obstacle the door stops and reopens If during pause it detects the presence of an obstacle the door remains open 7 z Input COMMON 8 INTERNAL RADAR input N O contact Activation causes the door to open It is not active when the program selector is set to Incoming only or to Night lock 9 EXTERNAL RADAR input N O contact Activation causes the door to open It is not active when the p
65. ly used if the 12 digital programmer is connected to two operators for the management of two automatic doors and the symbol in the top right section of the display indicates 1 if the displayed information refer to operator 1 or 2 if they refer to operator 2 Every touch on F3 button allows to switch from 1 to 2 and vice versa fthe S12 programmer only manages a single operator the symbol 1 is displayed at the top right e The F1 button allows to switch to the event memory to display error messages press it again to return to the information area e he EXIT button allows to return to main view of the door work program DIAGRAM 2 I1 I2 INFORMATION AREA E1 E2 EVENT MEMORY 5 F1 F1 F1 F1 F1 F1 ERROR ERROR ERROR ERROR ERROR ERROR EVENT EVENT EVENT EVENT EVENT EVENT MEMORY MEMORY MEMORY MEMORY MEMORY MEMORY INFORMATION INFORMATION INFORMATION INFORMATION INFORMATION AREA AREA AREA AREA AREA F1 F1 F1 F1 F1 INFO INFO INFO INFO INFO The purpose of the diagram is illustrating the path to be followed to view the information and the event memory the texts included in figures refer to the memory cells appearing on the left side of the display when viewing the information or the errors 47 Refer to the following tables for the list of information and error messages INFORMATION AREA EET s ANN o dili It displays the door opening closing cycles which have been carried out since the latest
66. maintenance intervention This counter must be reset by the person in charge of maintenance after each intervention please refer to the Maintenance paragraph It displays the door opening closing cycles which have been carried out since the first start up of the operator BE onini It displays the software release of the LOGIC2 control unit A microcontroller KI Identification number Identification number including data for manufacturer use BE nini It displays the software release of the LOGIC2 control unit B microcontroller The events memory stores the last 5 error messages in chronological order When all the 5 memory cells are full of messages the following event stored shall be located in E1 cell the other memory events are shifted by one position and the event in E5 cell shall be deleted The events memory stores messages divided into warnings and errors Stored errors are signalled by displaying the symbol directly from the main screen of the work program access the events memory to show the relevant message The warnings stored are not shown in the main screen of work program but only stored in events memory 48 EVENT MEMORY Massages which may be displayed in cells E1 through E5 WARNINGS SYMBOL MESSAGEONDISPLAY MEANING J PROBLEM RESOLUTION SOFTWARE RESET OPENING OBSTACLE CLOSING OBSTACLE BATTERY DISCHARGED Generic malfunction which triggered a microcontroller reset The doo
67. menu sections concerning parameters and functions setting initial set up and maintenance area Default preset technical password is A A A A A A A A A A WARNING It is recommended to change the default technical password and be very careful not to forget it b PRIMARY PASSWORD for the system s owner user It is a 5 character password used by the user to prevent unauthorized persons from having access to 512 programmer and change the work program Using a primary password is optional and must be enabled by system s owner Default preset primary password is WARNING When enabling the password be careful not to forget the access combination c SERVICE PASSWORD for user It is a 5 character password that the system s owner may divulge to persons to be authorized to use 12 programmer The service password only allows changing the automatic door work program Default preset service password is To change the service password it is necessary to have access by primary password Use the button to move the selection arrow downward and the F2 button to move the arrow upward 43 21 1 HOW TO CHANGE THE TECHNICAL PASSWORD e Select TECHNICAL PASSWORD e Press OK F1 button CURRENT C PASSWORD e Type the default preset technical password by pressing 10 times on A button R e Type the new technical password selecting a combina
68. mitted by the buzzer to indicate that the limit power delivered by operator has been reached especially if leaf dimensions and weight are close to the limits allowed A short noise signal by the buzzer during start in opening is to be considered as normal as the pick up phase is the moment requiring maximum force Adjust the thrust power by P04 parameter of 12 programmer see Adjustment of parameters paragraph To deactivate the buzzer noise signal when the power limit is reached set up F33 function to ON see Functions setup The buzzer noise signal for almost the entire stroke means that the leaf exceeds the limits allowed or frictions exist on the fixture in this case the movements of automatic door are difficult and the opening closing cycle could not be completed Check that the electric lock and the manual release are working properly If the operator is equipped with emergency battery connect the battery connector to the BATTERY connector on the LOGIC2 control unit and make sure that the battery charger board is inserted into the J1 connector of the control unit for detailed information about operation with the emergency battery please refer to para Emergency opening device Safety on impact placing an obstacle in front of the leaf while it is in motion will cause the leaf to stop and the motion direction to be reversed when performing the next cycle the leaf shall slow down in the point where it had come into contact with t
69. n The installer must prepare suitable fairleads on the side panel of the operator control unit for the passage of the cables and ensure wire stability inside the operator control unit prior to the start up of the automatic door in order to prevent any contact between the electric cables and the moving parts of the automatism e TERMINAL BOARD M1 F N GROUND 230Vac 50 60Hz mains supply phase at terminal F neutral at terminal N ground connection at terminal Ground the operator by connecting the ground cable from the line to the Faston connector on the aluminium transom connect the second ground Faston on the transom to the ground terminal on the electronic control unit The line is protected by 5A fuse F1 On the power supply mains foresee an omni polar switch selector with contact opening distance at least of 3 mm The power supply line must be protected against short circuit and dispersion to ground Separate the 230Vac power supply line from the very low voltage line control unit relative to control and safety accessories e TERMINAL BOARD M3 Power supply of external accessories SENSORS POWER SUPPLY rprearranged SENSORS 13Vdc output for power supply to accessories radars and sensors Max load 500mA Y u 17 Positive terminal 13V 18 z Negative terminal O The presence of the output voltage is displayed by the DL2 led 16 TEST terminal for safety sensors prearranged with test function 24 TER
70. n UR1 module Terminal 1 of the UR1 module of control unit 1 must be connected to terminal 14 STOP I of control unit 2 Terminal 11 COM of control unit 2 must be connected to terminal 2 of its own UR1 module Terminal 1 of the UR1 module of control unit 2 must be connected to terminal 14 STOP I of control unit 1 Terminals 7 COM of both control units must be connected to each other If you wish to by pass the interlock operation and allow the two doors to operate independently you need to connect an ON OFF switch in parallel between terminals 12 AUX1 and 7 Common of both operator control units This way when the switch contact is open the interlock is enabled while when the switch contact is closed the interlock is disabled and the two automatic doors can operate independently To enable interlocked operation you need to install the 12 digital programmer as program selector You cannot use the EV MSEL mechanical key selector 57 29 2 INTERLOCK APPLICATION WITH INDEPENDENT INTERNAL DETECTORS The internal radars of each door are used independently when the DOOR 1 distance between the two doors is such that there are no Mel in the detection field of the two internal radars Setthe F26 function to ON on both door operators Select which of the two doors must open first in case of EXTERNAL simultaneous command on both RADAR N yo F27 OFF door opening 0 5 seconds after the command is DOOR 2 issued F27
71. n screen of the work program F2 on Whenever an opening command is issued the door will only open by a few centimetres the chemist s opening distance is set through the P23 parameter on the 12 programmer and must not exceed the length of the slot existing in the chemist s electric lock bracket When the door is open the leaf cannot be further opened manually because the Lock 2 chemist s electric lock prevents the leaf from moving To disable the chemist s function and allow the door to fully open press the F2 button again on the S12 digital programmer F2 off 59 31 MEANING OF BUZZER WARNING SIGNALS The LOGIC2 control unit of the operator is equipped with a buzzer emitting a set of warning signals whose meaning varies according to the number of emitted beeps and to the signal duration WARNING SIGNAL BEEP MEANING 8 short and fast BEEPS Operator not set up when powered 3 short BEEPS Self diagnosis failure on the PRJ38 photocell 4 BEEPS Intervention on the PRJ38 photocell 4 short BEEPS Set up cycle initial phase starting warning Prolonged sound 3 seconds Initial set up completion indication Prolonged and intermittent sound during motion The power limit the operator can supply to the motor is exceeded while the leaf is in motion This warning activates if the F33 function is set to OFF To disable this warning set F33 to ON 1 BEEPS After powering the operator
72. nly used if the S12 digital programmer manages two automatic doors When the work program main screen is displayed the F3 button allows to switch from operator 1 to operator 2 and vice versa The number 1 appears on the display when operator 1 is selected the number 2 appears when operator 2 is selected Select the number of the automatic door operator on which you wish to set the work program PROGRAMMED MAINTENANCE message If the PROGRAMMED MAINTENANCE message appears on the display please j lt j contact the authorised support centre to request a system maintenance intervention 4 PROGRAMMED PT 123 pe 36 18 GENERAL PROGRAMMING MENU To enter the general programming menu while the automatic door operating program is shown on display keep button pressed for about 5 seconds The programming menu consists of different sub menus divided by subject Diagram 1 Choose the section you wish to access by pressing the F1 gt gt button The selected menu icon is highlighted and the section title appears at the top of the display To enter the selected sub menu give a quick pulse on ENTER button To exit the general programming menu and return to the operating program view press EXIT DIAGHAM 1 PAVIE HES 8 k POTEHTIOMETERS 4 UNUSED SET UP FUNCTIONS AND POTENTIOMETERS LANGUAGE SECTION SECTION SECTION EAI DAILY OP UP 4 at SERVICE E
73. ntact with the ledge Increasing the value will increase the thrust exerted by the leaf onto the closing ledge Wind stop when the door is closed It sets the intensity of the contrast force exerted by the motor should anyone attempt to forcibly open the door Increasing the value will increase the intensity of the force contrasting the attempt to open the leaves Distance from the final closing ledge at which the door reopens if an obstacle is detected during the closing cycle When decreasing this value to 0 the motion direction will be reversed if an obstacle is detected up to 5mm from the final closed door ledge Below this distance the door stops and doesn t reopen Distance between the end of the leaf stroke during opening and the mechanical opening limit switch Increasing the value will increase the distance between the leaf and the mechanical limit switch with respect to the value stored during set up Decreasing the value will decrease the distance between the leaf and the mechanical limit switch with respect to the value stored during set up Waiting time between 2 consecutive door crossing warning gongs It sets the waiting time elapsing between the gong buzzer activation as the person passes through the automatic door to its reactivation as an other person passes to prevent repeated consecutive gongs Please refer to the Gong function paragraph Start delay when opening with respect to activation of electric lock It sets the time aft
74. ommand on the OPEN input manned mode 56 29 INTERLOCK SYSTEM The interlock system is used to connect two automatic doors when a door can only open if the other is closed For the electrical connection between the LOGIC2 control units of the two operators you need to use a UR1 module optional for each control unit Plug the UR1 module into the J7 OUT3 connector of the LOGIC2 control unit 29 1 ELECTRICAL CONNECTION FOR INTERLOCK FR3 VDC GND OPEN E e 1 COM RADIN RADEX START COM AUXI 0 2 AUX2 me 13V P PS1 ENCODER MOTOF 558 o 1j E J aa a a ur j M3 START J3 J4 J5 LOCK 1 J6 LOCK 2 J7 OUT 3 i LOGIC2DOOR1 UAOYVHO AHaLIVg SWITCH ON OFF FR3 VDC GND OPEN E 1 COM RADIN RADEX SART AUX1 2 STOP I AUX2 TEST 13V 0 9 10 12 13 14 15 16 17 18 PS1 ENCODER MOTOF J8 START J3 J4 J5 LOCK 1 J6 LOCK 2 J7 OUT 3 LOGIC2 DOOR2 ael is The dotted line of the ON OFF switch connected to the AUX 1 input is used to disable the interlock operation connection not essential for the system operation Switch OFF contact open interlock ON Switch ON contact closed interlock OFF The above diagram shows the electrical connection between the two doors ensuring that they are interlocked during operation e Terminal 11 COM of control unit 1 must be connected to terminal 2 of its ow
75. ormance and reliability depend on its proper installation on regular maintenance and following the manufacturer sinstructions ANTI PANIC BREAKOUT SYTEM for emergency exit Clear passage 700 1200 mm 1 anta 1 leaf 1400 2400 mm 2 ante 2 leaves Max Loading capacity 100 Kg CERTIFICATION AND CONFORMITY complies with the following European Directives and Standards Machinery Directive 2006 42 EC Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Breakout systems for emergency exit Test Report n 251018 dated 30th January 2009 EUROPEAN STANDARDS EN 16005 EN 13849 1 EN 13849 2 EN 61000 6 2 EN 61000 6 3 EN 60335 DIN 18650 1 DIN 18650 2 www adsf co uk UK OD Premis Slide Operators AUTOMATIC ENTRANCE SPECIALISTS OPremis Euroslide CONTENTS GENERAL SAFETY WARNINGS GENERAL SAFETY OBLIGATIONS 1 MODEL DESCRIPTION 2 TECHNICAL SPECIFICATIONS OF THE PREMIS OPERATOR MECHANICAL COMPONENTS OF THE PREMIS SLIDING DOOR OPERATOR 3 PREMIS OPERATOR COMPONENTS 4 TECHNICAL DRAWINGS COMPONENT ARRANGEMENT 5 COVERING CASING 6 ADJUSTING THE BELT TENSIONING 7 POSITIONING THE MECHANICAL LIMIT SWITCH 8 ANCHORING THE LEAVES TO THE CARRIAGES AND ADJUSTING THEM 9 INSTALLATION DIMENSIONS 10 SLIM ELECTRIC LOCK MECHANICAL COMPONENTS OF THE PREMIS T TELESCOPIC DOOR OPERATOR ANNEX PREMIS T TELESCOPIC DOOR OPERATOR supplied among the documents accompanying the PREMIS T operato
76. our during a power failure a EV EBSFSA FAIL SAFE In the case of a power failure mains power supply and emergency battery power the electric lock will free the leaves which can then be moved manually b EV EBSFSE FAIL SECURE In the case of a power failure mains power supply and emergency battery power the electric lock will keep the leaves blocked c BISTABLE EBSBIS In the case of a power failure mains power supply and emergency battery power the electric lock will remain in its current position Therefore the leaves are free if the electric lock was not activated or will remain blocked if the electric lock was activated Electric locks are supplied in Kit including coupling brackets and fastening accessories 70 2 POSITIONING and ELECTRIC CONNECTION The dimensions for fastening the electric lock on the automation are specified in Paragraph TECHNICAL DRAWINGS The electric lock is fastened to the automation by 2 M6 X 10 screws on M6 nuts which are located in the special lower slot in the transom The sliding carriages must be regulated so that when the leaf is in the closed position the electric lock lever can hook to the carriage bracket and keep the leaves blocked x LI m The electric lock kit includes a power supply cable This cable has two wires on one end that are connected to the electric lock solenoid wires with the specific terminals The oth
77. r page 4 10 10 11 12 14 AUTOMATIC ENTRANCE SPECIALISTS OPremis Euroslide ELECTRONIC SECTION 11 ELECTRIC ARRANGEMENTS 12 ELECTRIC CONNECTIONS 13 S12 DIGITAL PROGRAMMER SCOPE AND CONNECTIONS 14 COMMISSIONING OF AUTOMATED DEVICE INITIAL SET UP 14 1 FIRST START OF 12 DIGITAL PROGRAMMER 14 2 USE OF 12 DIGITAL PROGRAMMER 14 3 SERIAL COMMUNICATION SETTINGS 14 4 INITIAL SET UP 14 5 FUNCTIONAL TESTING 14 6 INPUT DIAGNOSTICS 15 BATTERY OPERATED OPENING DEVICE 1 16 BATTERY OPERATED OPENING DEVICE EV BAT2P 17 PROGRAM SELECTORS 17 1 MECHANICAL KEY SELECTOR EV MSEL 17 2 512 DIGITAL PROGRAMMER USED LIKE PROGRAM SELECTOR 18 GENERAL PROGRAMMING MENU 19 FUNCTIONS AND SETTINGS 19 1 FUNCTION SETTING 19 2 PARAMETER SETTING FUNCTION TABLE PARAMETER TABLE 20 LANGUAGE 21 PASSWORD MANAGEMENT 21 1 HOW TO CHANGE THE TECHNICAL PASSWORD 21 2 HOW TO CHANGE THE PRIMARY PASSWORD 21 3 HOW TO CHANGE THE SERVICE PASSWORD 21 4 ENABLING USER PASSWORD USAGE 21 5 DISABLING USER PASSWORD USAGE 22 INFORMATION AND EVENT MEMORY 23 MAINTENANCE 24 UR1 MODULE 24 1 UR1 MODULE IN THE OUT3 CONNECTOR OF THE LOGIC2 CONTROL UNIT 24 2 UR1 MODULE IN THE OUT4 CONNECTOR OF THE LOGIC2 CONTROL UNIT 25 SAFETY SENSORS 25 1 OA AXIS T SENSOR 25 2 OAM DUAL T SENSOR 25 3 OA PRESENCE T SENSOR 26 GONG FUNCTION 27 EN RF1 RADIO RECEIVER 28 FORCED CLOSING FUNCTION 29 INTERLOCK SYSTEM 29 1 ELECTRICAL CONNECTION FOR
78. r has come into contact with an obstacle during opening this caused the motion direction to be reversed The door has come into contact with an obstacle while closing this caused the motion direction to be reversed Low battery charge warning in the absence of mains power supply during battery powered operation System restoration is automatic If the problem persists remove the obstacle or check that the leaf slides properly If the problem persists remove the obstacle or check that the leaf slides properly As soon as the mains power supply is restored the battery will be recharged ERRORS SYMBOL MESSAGE ON DISPLAY MEANNG ACTION POWER FAULT INITIAL SETTING ERROR ENCODER OR MOTOR ERROR OPENING SAFETY SENSOR ERROR CLOSING SAFETY SENSOR ERROR BATTERY FAULT BRAKING FAULT EEPROM REGISTER FAULT w G av ADDL NA The motor piloting signal test has detected a fault The operator has not managed to complete the initial set up Signals from the encoder are not detected detected during the encoder Failed opening safety sensor test Failed closing safety sensor test The system signals a damage to the battery The closing brake signal test has detected a fault Failed internal memory register test l operation check 4 9 The system restores automatically after a few seconds and carries out an other testing attempt If the problem persists
79. rective Disconnect the power supply before working on the automation and before opening the cover Maintenance is of fundamental importance for the proper operation and safety of the automation Check the efficiency of all parts every six months Use only original spare parts for maintenance and when replacing product components Cleaning operations must be performed with the power supply disconnected using a damp cloth Do not deposit or let water or other liquids penetrate into the Euroslide operator or the accessories that are part of the system It is recommended to take out a maintenance contract The automatic sliding doors must be designed and installed in a way to protect users against the risk and danger of crushing impact shearing and conveying between the door and adjacent parts near the door The person responsible for starting up the automation must perform a risk assessment based on the place of installation and the type of users that could use the automatic door Safety during the opening cycle is ensured by the application of one of the following methods e Safety distances between the secondary closing edge and the adjacent environment parts Force limitation on the leaf e Use of protection devices sensors complying with standard EN12978 e Installation of protections like fixed panels or barriers preventing people from reaching the dangerous points Low Energy motion w Safety during the closing cycle is
80. rogram selector is set to Outgoing only or to Night lock 10 START input N O contact Activation causes the door to open It is not active when the program selector is set to Night lock 25 COE 1 SVEA ALM 2 7 SAFET STER CCH NGE C 1 BAG nx START 5 7 E 000009 M5 e TERMINAL BOARD M6 E O 2 Input of safety sensor for opening E O 2 N C contact The operation of safety sensor for opening E O 2 must be enabled by N DSEL digital programmer function F14 ON The door opens at slow speed if the sensor detects an obstacle during opening function F19 OFF The door stops if the sensor detects an obstacle during opening function F19 ON E C 2 Input of safety sensor for closing E C 2 N C contact The operation of safety sensor for closing E C 2 must be enabled by N DSEL digital programmer function F12 ON If during closing sensor detects the presence of an obstacle the door stops and reopens If during pause sensor detects the presence of an obstacle the door remains open FR3 PRJ38 PHOTOCELL receiving capsule signal brown cable power supply positive for the receiving capsule blue cable GND power supply negative for the receiving capsule black cable e TERMINAL BOARD M7 FT power supply positive of the transmitting capsule blue cable Ft1 PRJ38 PHOTOCELL transmitting capsu
81. s the purpose of the selected function the F1 button sets the function status to OFF the F3 button sets the function status to ON the F2 button allows to switch to the next function the button allows to return to the previous function For information about the operation of each function please refer to the FUNCTION TABLE below 19 2 PARAMETER SETTING LAs OPENING SPEED P MAX 10 CH SECOHD 2 H x EXIT 1 INZ In this section the display describes the selected parameter type the F1 button decreases the set percentage value the F3 button increases the set percentage value the button allows to switch to the next parameter the F2 button allows to return to the previous parameter For information about the operation of each parameter please refer to the PARAMETER TABLE below 38 FUNCTION TABLE FUNCTION STATUS F01 F02 F03 F04 05 F06 F07 08 09 10 11 12 F13 F14 F15 F16 F17 F18 F19 F20 OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF ON EXPLANATION Choice of the work program selector S12 digital programmer Choice of the work program selector EV MSEL mechanical selector Standard function the electric block activates when the door is closed only in the N
82. screw By moving the release knob to the UNRELEASED position only the orange part of the label must be seen with the drawn black arrows F Insert the flexible sheath into the special hole on the side panel Use the whole which is furthest from the register to ensure that the sheath retains a wide enough bending radius LEFT SIDE PANEL RIGHT SIDE PANEL 16 Insert the sheath using the fairleads until reaching the electric lock Cut off the excess sheath Insert the steel cable into the release knob and the sheath until reaching the electric lock Fit the sheath stop on the tip of the cut sheath Insert the compression spring and insert the metal cable inside the special release anchor then lock it with the screw clamp Adjust the cable tension so to give the spring a light pre load NOTE Check that the manual release works when the knob is in the locked position the electric lock must work normally When the knob is in the released position the electric lock must remain open and free the leaves Cut the exceeding steel cable from the release anchor In case of FAIL SECURE electric lock by releasing the release the electric lock will close In case of a bistable electric lock by releasing the release it will open In case it is necessary to manually close the door with a bistable electric lock it will be sufficient to lift the core of the secondary solenoid with a screwdriver 10 4 INSTALLAT
83. screw the A screws into their seats without tightening them Adjust the height of the leaf by means of the control screw B and fully tighten the two A screws Adjust the leaf horizontally by means of the eyelets E provided in the movable part of the carriage To ensure that the automated equipment works properly it is important that the mobile leaf is perpendicular to the transom Adjust the height of the opposing wheel by operating the adjustment screw D so that the wheel skims the top inner part of the transom but without exerting any pressure Then manually move the leaf until it reaches the end of stroke and check that there are no frictions at any point otherwise adjust the opposing wheel position again DOUBLE DOOH LEAF WIIHOUI ELECIHIC LOCK OA A k fe 11 9 INSTALLATION MEASURES REQUIRED TOOLS Tape measure drill level thin flat head screwdriver medium sized flat head screwdriver cross head screwdriver Allen wrenches with handle sizes 3 4 5 6 flat head wrench 10 The transom must be fastened to a flat surface solid enough to bear the weight of the leaves to be used If the wall or the support do not meet these characteristics you will have to provide for a suitable tubular element as the transom is not self bearing Fasten the transom by means of M6 steel or equivalent anchors The fastening points must be distributed alternately between the reference lines on th
84. t terminals 1 2 of the UR1 module The diagram above illustrates the electrical connection in the case a 12Vdc supply is used by taking the power supply directly from terminals 17 18 of the LOGIC2 control unit To activate the GONG function use the S12 digital programmer and set function F39 to ON at this point each time that the safety sensors are operated when closing the door the GONG will sound for 2 seconds To change the waiting time elapsing from when the GONG buzzer is activated to the next time it is activated engaging the closing safety sensors act on the P19 parameter on the 12 digital programmer This waiting time is used to prevent the buzzer from sounding continuously in the case of the passage of a high number of people This time is reset when the door is completely closed The table below provides some information about the waiting times according to the set value of P19 2 400 GONGOF Now the GONG function is definitely ON By crossing the automatic door and by engaging the closing safety sensors the audible indication of the GONG will sound for 2 seconds the GONG will then be inhibited for the waiting time set previously with P19 Once the waiting time has expired the GONG will be activated again for 2 seconds if the door is crossed engaging the closing safety sensors WARNING If the interlocking function is used F26 ON the gong function will be automatically set to OFF 54 27 EN RF1 RADI
85. tion of 10 characters from the letters A B C D REPEAT HEU PASSWORD PASSLIORD e tis required to repeat the new password so type the previous combination again e lf the password typed is correct PASSWORD is shown on display for one second and the general programming menu is restored From this moment on when having access to general programming to enter initial set up functions and adjustments settings of serial communication and maintenance section the new stored password needs to be typed The password is not required afterwards when switching sections without exiting the general programming menu If the password typed is not correct PASSWORD ERROR is shown on display and the general programming menu is restored 21 2 HOW TO CHANGE THE PRIMARY PASSWORD e Select PRIMARY PASSWORD e Press OK F1 button CURRENT PASSWORD e the default preset primary password A A A A A by pressing 5 times on A 22WORL button If the primary password is not the default password as it had already been changed before type the currently used primary password e Type the new primary password selecting a combination of 5 characters from the letters A B C D 44 REPEAT e tis required to repeat the new password so type the previous combination again fthetyped password is correct the PASSWORD message appears on the display for one second then the system swit
86. to be used NOTE e Should the button of an already saved transmitter be pressed during the programming phase the L1 led of the receiver will blink slowly for 5 times MEMORY FULL e A maximum of 250 transmitters can be saved on the receiver When the last memory cell available ZC 1 is reached the L1 led will blink slowly for 5 times d Once the transmitter saving procedure is finished exit the programming mode by pressing and holding the SW1 button until the L1 led turns off o 4 USE OF THE RADIO CONTROL By pressing the button of a saved SPYCO transmitter the automatic door opens and the L1 led of the receiver will remain on until the button of the transmitter is released The radio control opens the door in all the automation work programs 5 CANCELLATION OF THE MEMORY OF THE RECEIVER Should it be necessary to cancel all the saved transmitter codes from the memory of the EN RF1 receiver proceed as follows a Extract the EN RF 1 receiver from the connector of the LOGIC2 control unit b Keep the receiver SW1 button pressed and then couple again the EN RF 1 receiver to the J9 connector of the LOGIC2 control unit C Release the EN RF 1 receiver SW1 button only when the L1 led of the receiver starts blinking d The L1 led will be blinking very fast for approx 8 seconds thus indicating the cancellation of the memory of the receiver e When the cancellation of the memory of the EN RF 1 receiver is finished the L1 led will turn of
87. to enable the usage of user passwords and return to the PASSWORD MANAGEMENT menu To return to the work program view press the EXIT button twice e From this moment on whenever the user wants to access to 512 digital programmer to change the automatic door work program the primary or service password must be typed When the user decides to enable the password usage it is recommended to change the combination of both primary and service password 21 5 DISABLING USER PASSWORD USAGE e From the PASSWORD MANAGEMENT section select PASSWORD ON OFF Press OK F1 button CURRENT PASSWORD PASSWORD e Type the primary password ON PASSWORD ON OFF PASSWORD OFF EXIT OFF e Press OFF F1 button to disable user password usage To return to the general programming menu press the EXIT button twice From this moment on the access to 512 digital programmer like program selector is free 46 22 INFORMATION AND EVENT MEMORY 12 digital programmer allows displaying information on automation and accessing to events memory where fault errors are stored After displaying the automatic door work program press the button for 5 to enter the information area Diagram 2 The buttons inside the information area are used as follows The v button allows to move to the next information or event in event memory e The F2 button allows to move to the next information or event in event memory e button is on
88. values for the total weight of the movable leaves range between 30 Kg and 320Kg Setting of the movable leaf total weight to avoid exceeding the impact force limits during closing DIN18650 When selecting the value of the movable leaf total weight the door closing speed will be automatically adjusted by the operator to avoid exceeding the impact force limits during closing set by the DIN18650 standard When the value is set to 00 Kg the function is disabled and the closing speed can be set using the P02 potentiometer in this case the installer must take other safety measures in compliance with the regulations in force The setting values for the total weight of the movable leaves range between 30 Kg and 320Kg Use the F24 function to specify whether the automatic door has a single leaf or two leaves 42 20 LANGUAGE e Use the F2 amp buttons to move arrow to the desired language e Press EXIT SET button to return to general programming menu 21 PASSWORD MANAGEMENT PASSWORD MANAGEMENT a PRIMARY PASSWORD gt TEMPORARY PASSWORD d TECHNIQUE PASSWORD PASSWORD OH OFF NI This section shows three types of password a TECHNICAL PASSWORD for technical personnel in charge of installation and maintenance It is the 10 character password of the installer who starts the system Using the technical password is compulsory to prevent unauthorized persons from having access to general programming
Download Pdf Manuals
Related Search
Related Contents
Franck Mouteault Patrice Fort datasheet: pdf Samsung Galaxy Camera (3G) מדריך למשתמש CyberPower BRG1000AVRLCD uninterruptible power supply (UPS) TVCC50030 TVCC50530 Cables Direct 4m Cat5e Montageanleitung Cisco Unity VM, 300 users (w/ 16 sessions, no media-orderDVD) 簡易マニュアル Manuale YZF R125 Copyright © All rights reserved.