Home
Smart Pulse Manual
Contents
1. Insert the left index finger into the device as in the picture 7 Right hand or other fingers are not clinically verified therefore the test result will not be correct using them 3 When the word READY appears on the screen of the device click on the START button Picture 7 When the user clicks on the START button if the message fail to initialize the serial port appears after closing this popup window move back to the initial screen Close the program and restart it Stress measurement shall take 3 minutes and Vascular Health measurement will be approximately 30 seconds When the measurement is completed it will be automatically moved to the Result Screen 10 5 View Stress Vascular Health Result Screen Picture 8 PULS En Details of Test Result KEMER no kuk Yoo Gender Mate Pe Oe our heart rate is no normal in comparison with the same Mean Heart Rate Measurement Page Ectopic Beat Plethysmograph When the pressure fluctuation of blood in aorta with the shape of waves by the Stress Analysis Arterial Health Analysis constriction of heart reaches into the peripheral nerve the change inthe amp volume of blood flow at the tip of finger Autonomic Nerve cae DENE D will be appeared It is called Pulse wave Plethysmogram which is shown Physical Stress AE by detecting this change in volume Arterial Elasticity our vessel state and blood circulati
2. However when the name of the user who is already registered is typed in the user s name will appear on the window located on the right side of the screen and when the NEXT button is pressed after selecting the name the screen will move to the Measurement Screen The RESULT TRANSFER button moves the user s data that is stored in the device to the computer The Result button is for checking the measurement result 9 Clicking on the DELETE button will delete the user that has been selected from the right side of the screen Picture 5 This will delete the user and all of the measurement data associated with that user This information cannot be retrieved Clicking on the NEXT button after selecting or registering a user causes a move to the measurement window D Clicking on the BACK button causes a move to the Start Screen 4 Measurement Picture 6 Accelerated Plethys mograph HRV Tachogram Picture 6 A new user can initially register from Registry of User Information Amendment window and a user who is already registered will have his her name appear if the name is selected from the window on the right side of the screen or typed in beside Name Select the name and click on the NEXT button to move to the measurement window and start measuring Check if the Smart Pulse is turned on and insert the left index finger Check if the word READY appears on the screen
3. Picture 4 Click on the Setup button from the Start Screen in Picture 3 For the Reference Type select ASIA for Asian and WEST for Westerners If the user name is recorded the recorded name will appear under the Total Result when the result report is printed If the phone number is recorded it will appear under the Total Result when the result sheet is printed Select language Korean English Japanese Chinese Beep has a function to turn the beep sound of the device On or Off When the time on the device is incorrect press Time Set Function to have the time automatically set up identical to the time on a computer If set up has been completed for everything click SAVE button to save the settings By clicking on the CANCEL button the settings will not be saved The data cannot be retrieved if it is not saved 3 User Registration and Modification Picture 5 PULSEN G d Male AOF Name Gender Date of Birth en er E r E A Name Byung kuk Yoo Date of Birth 1971 year month day Picture 5 When Vascular Health or Stress is measured by clicking on the relevant buttons the screen moves to Registry of User Information Amendment Clicking on the REGISTRATION button after recording the user s gender name and date of birth from the Registry of User Information Amendment window registers the contents in the window on the right side of the screen
4. n LTD AND THEIR AFFILIATES COLLECTIVELY SILICON LABS H Silicon Laboratories CP210x YCP Drivers for Windows P 2003 Server Vista DEVELOPED CERTAIN MATERIALS E G DEVELOPMENT TOOLS date CODE Silicon Laboratories CP210 VCP Drivers for Windows P 2003 Server Vista _2 e SiL EMBEDDABLE CODE DLLs SOFTWARE COMPUTER PROGRAMS AND OTHER THIRD PARTY PROPRIETARY eae tit te LICENSED MATERIALS ae You MAY USE IN CONJUNCTION WITH SILICON LABS MCU PRODUCTS ANY USE OF THE LICENSED MATERIALS IS SEET T0 THIS END USER LICENSE gt Silicon Laboratories CP210x YCP Drivers for Windows xP 20045 Silicon Laboratories CP210x YCP Drivers for Windows xP 20076 x Choose Destination Location a Welcome to the InstallShield Wizard for Silicon Danaa aaa Laboratories CP210x YCP Drivers for Windows cere Soren eee wee Setup will install Silicon Laboratories CP210x VCP Drivers for Windows XP 2003 The InstallShield Wizard will copy Silicon Laboratories Server Vista v6 4 in the following folder CP210x VCP Drivers for Windows XP 2003 Server Vista SE Aorta poir combed To contra Gack Nad To install to this folder click Next To install to a different folder click Browse and select gt z t another folder Destination Folder c OP210x Windows_XP_S2K3_Vista_7_3 Cancel Silicon Laboratories CP210x VCP Drivers for Winaoows xP 20078 x Ready to Install the Program a The wizard is ready to begin in
5. the latter case left click the mouse to select the data while Ctrl button is pressed from the keyboard In order to change the data after an incorrect selection of the data being saved press the Ctrl button and left click your mouse again to cancel the selection If the user moves out from the RESULT TRANSFER with the remaining data the device has retained the data When the user measures another person and wants to move the data to a computer by clicking on the RESULT TRANSFER button all of previous data should be stored under a new name The new data can then be moved and saved D After finish moving the result as the measured users data is removed the number shown in of Picture 1 decreases Click the user s name again from the window on the right side of the screen then click the RESULT button 7 Measurement Method 1 Start Picture 3 Arterial Health Stress Cumulative Test Measurement Measurement Result Picture 3 Start the Smart Pulse T program while the device is connected to a computer with a USB Cable To start measuring Vascular Health click on the Arterial Health Measurement button from the Start Screen 3 To start measuring Stress and Vascular Health click on the Stress Measurement button 2 Set up button function Picture 4 Reference Type VEST x User Name MEDICORE Beep FON OFF Telephone 02 2056 2600 Time set EO SET ai r laleler lel me ENGLISH
6. Smart Pulse Manual Medicore Co Ltd Vascular Health Stress Check up Table of contents 1 What is the Smart Pulse 2 seeps eee ene eens uedueeneeeuendeneeueduene ts 2 2 Product CONTIN INES acta ceca cee eee eee eee eee eee eee 2 3 EUS UREN OM sec E cg sete eee eee Se EEE 2 7 Wi 1 24 189 Me ipa Gee ne Pn Pn nn en EE Dn ee ee eee eee eee ree 4 S FoncUonror r each Da a a a A AEAEE EEE E E 4 6 TV ASU SING POCO oeer a A A E E EEE 6 7 Measurement ISBN ioc 8 8 Precautions during the PSS UI CPN ccs 12 i Usage Precautions ceo A EAA EE E 13 10 Product Specih aO oaran a a a AAAA AAEN rr EEO E EAT ON E E 13 1 What is the Smart Pulse The Smart Pulse is a portable self measurement medical device The measurement is easily done at home or at the office The measurement results are available after connecting the Smart Pulse to a computer The device is used to detect adult diseases in the early stages by checking the functioning of the autonomic nervous system the status of their stress the aging of their blood vessels and their blood circulation by analyzing small changes in their heartbeats 2 Product components Main body Module 1 Manual 1 3 USB Cable 1 Software CD 1 3 Installation D When the user inserts the provided CD into the CD or DVD drive the install program will run automatically If the program doesn t run automatically the user can run the Install program of the Smart Pulse manually
7. The program can be installed by the process shown below Install Finish Next I accept the terms of the license agreement Next Next Install Finish Install Confirm haa SmartPulse 1 0 0 Setup SmartPutse 1 0 0 Setup Welcome to the SmartPulse 1 0 0 Completing the SmartPulse 1 0 0 Setup Wizard as Setup Wizard This wizard wall gee you through the instalation of SmartPulse 1 0 0 has been installed on your computer SmartPulse 1 0 Click Finish to close this wizard It i recommended that you close af other applications before starting Setup This vill make it possible to update relevant system Files without having to reboot your EEEN VM Rum SmatPulkse 1 0 0 Click Instal to start the installation Silicon Laboratories CP210x CP Drivers for Win L xP 200f63 Existing Installed Instances Detected F Pil License Agreement Select the appropriate application instance to maintain or update z Please read the following license agreement carefully Spi has detected one or more instances of this application already installed on your system You can maintain or update an existing instance or install a completely new instance END USER LICENSE AGREEMENT OF IMPORTANT READ CAREFULLY Install a new instance of this application BEFORE AGREEING 10 TERMS Maintain or update the instance of this application selected below Display Name SILICON LABORATORIES INC SILICON LABORATORIES PETR TONES PTE a n
8. device to the computer 6 Measurement Procedure 1 Measuring directly by connecting the device to a computer Run the program while the device is connected to a computer by a USB Cable When the power button is held down the device will be turned ON and the start screen Picture 3 on the computer will display Clicking on the Setup button on the start screen Picture 3 will display the setup screen Picture 4 Fill out the information for Reference Type User name Telephone User language and Save it If set up was previously done with this computer click on the cancel button The Finger Out display will become READY when the left index finger is inserted deep into the device Select Arterial Health Measurement or Stress Measurement from the start screen Picture 3 For a new user click on the REGISTRATION button from Registry of User Information Amendment screen Picture 5 after inserting gender user name and date of birth The name of a user who is already registered will appear in the window on the right side of the screen Select the user for the test and then click the NEXT button to move to a measurement screen Clicking on the START button on the measurement screen will sound a beep if beep was turned on in the setup screen After about ten seconds there will be another beep signaling that the measurement has been started If the measurement is not working correctly and the message Co
9. dobe Reader Program should be installed on the computer because this User Manual is a PDF file 4 Name of each part Picture 1 Picture 2 Pulse Status Display While measuring the pulse red light will be flickering but while waiting the light will be yellow Measuring Mode Selection Display There are two modes which are 25beat and 3M beat measuring of heart rates in beat 25beat meauring of 25 beats of heart rate 3M 3 minutes When connected to a computer the device will be displaying DIRECT during the measurement Progress Bar Display When the 3 minute measurement mode is selected the measurement progress during the 3 minutes is displayed in a progress bar Display of the number of records stored Shows how many measurement results are stored The maximum is 5 tests Battery Display Shows the level of charge in the battery Pulse Rate Display Shows the pulse rate per minute during the measurement Pulse Display Shows the pulse that is being measured in a graph When a finger is not inserted Finger Out is displayed Power and Measurement Mode Change Button USB Cable connection 5 Function of each part 1 Power button function in picture 1 When the power button is held down while the device is off the power will be turned on After the power is turned on use short presses on the button without inserting a finger into the measurement device to select measurement mode 25b
10. eat 3minutes The power will be turned off when the button is held down When the left index finger is inserted into the device Finger Out will be changed to READY on the screen Use a short press on the button to start the measurement The power will be turned off when the button is held down During the measurement taking out the finger from the device or a short press on the button will stop the measurement The power will be turned off if the button is held down Automatic turn off function If there have not been any measurements after the power is turned on the power will be turned off automatically after 5 minutes If the finger is taken out from the device during the measurement or the measurement is stopped power will be turned off automatically after 5 minutes 2 Measurement Mode Selection Function in picture 1 Select the measurement mode 25beat 3minutes by a short press on the power button without inserting the index finger into the measurement device 3 Measurement Screen Change When the left index finger is inserted deep into the device the status will become READY automatically Start measuring with a short press on the power button The first 10 seconds after starting the measurement is a waiting time for the device to establish a normal wave The pulse status display in Picture 1 is shown in yellow and the pulse display is displayed in green Aft
11. er 10 seconds the pulse status display will flicker as it changes to red and the pulse display will be changed to blue The measuring time will be shown as the progress display bar in Picture 1 moves to the right side The Pulse Rate Display in Picture 1 is shown in real time The Pulse Display in Picture 1 will show Finger Out as the power is turned on READY when a finger is inserted into the device and the actual pulse wave form during the measurement When the measurement is done the Pulse Status Display in Picture 1 changes to yellow and the Pulse Display in Picture 1 will display READY 4 Display of the number of records stored in Picture 1 Up to 5 measurements are stored This means that before a sixth measurement is made the results of the 5 that are stored need to be moved to the computer If this does not occur the very first measurement stored will be deleted to make room for the new measurement Moving the data that is stored in the device to the computer by clicking on the RESULT TRANSFER button on the computer screen will change the number of measurements stored in the device to Zero 0 5 Measurement Method There are two measurement methods One is to measure directly by connecting the device to a computer The other is to measure without connecting the device to a computer and then looking at the results on the computer after the measurements are transferred from the
12. ill not be accurate if the person being tested has been drinking coffee smoking a cigarette or has taken medications 3 hours before the measurement Do not drink alcohol a day before the measurement During winter when hands are cold measurement error may occur due to capillary contraction Have the person warm their hands before measuring If left index finger is manicured the nail polish should be removed before measuring Light Absorption errors occur causing the measurement result to be inaccurate Wait 2 hours after eating before measuring Locations that are too quiet too noisy hot or cold are not good for the measurement Suitable temperature Between 22 26 degrees Celsius or 72 79 degrees Fahrenheit 12 9 Usage precautions 10 Do not put the device into water or touch it with wet hands Clean surface of the device using alcohol and dry cloth Do not drop or open the device Product Specifications 8 O amp O Size W x D x H 35mm x 57mm x 40mm Weight Approximately 50g two pounds Power 3 V DC Battery Life The battery is automatically charged when the device is connected to a computer by a USB CABLE and is fully charged after approximately 3 hours When measuring continuously the battery will last up to 3 hours The battery will likely last more than 12 hours in general use Recommended computer specifications and operating system A Pentium IV 1 Ghz over Memory 512MB ove
13. m Port Error appears the user should check the USB cable connection between the device and the computer Close the program Keep the device on and restart the program When the measurement starts the user should not move or talk and should not take a deep breath or do abdominal breathing but maintain a normal breathing pattern in a comfortable posture The measurement result will appear automatically for the user to see after the measurement is done 2 Check the results after a measurement has been made without the connection to a computer by connecting the device to the computer and sending the data that has been saved in the device to the computer When power button is held down the device will turn ON and the screen indicator will light Measurement mode 25beat 3 minutes can be selected by a short press of the power button when a finger is not inserted into the device The 25beat mode will only measure the Vascular Health The 3 minute mode will measure both the Stress and the Vascular Health 3 When the left index finger is inserted deep into the device the Finger Out display will change to READY A short press of the power button will cause a beep The measurement will begin after ten seconds When the measurement starts the user should not move or talk and should not take a deep breath or do abdominal breathing but should maintain a normal breathing pattern and be in a comfortable posture When the measu
14. on are good You are recommended to keep the current condition with the proper lite ndenecy and regular physical exercise See 56 100 K ae eevee TYPE 2 i E Result Foods like Fruits Bapana Spinach Lentil Pea Salmon Tuna supplements Ilke Follc acid Omega tatty acid and Tryptophan pre ns it may be helpful if you do regular exercise take and Mackerel will be neptal Dietary lt arcisea prescriptions professionals ne will be helpful For e an ae inshine and get consulting with Picture 8 In order to see older measurement results select the user from the Registry of User Information Amendment window then click on the Result Button New measurement results are automatically viewable after the measurement has been completed Inthe Result screen the results will be displayed differently according to the measurement mode In Stress Measurement Mode both Stress and Vascular Health results are shown but in Arterial Health Measurement Mode Stress result is not shown and only Vascular Health result is shown Results on the screen will be printed on the paper when PRINT button is pressed But the printer should be connected to the computer 6 View the Accumulated Measurement Result Picture 9 Gender Mae Mean Heart Rate sete TE Ectopic Beat Level of Aterial Health Physical Stress Mental Stress 41 Low Stress Resistance Stress Score Picture 9 11 In order to see
15. r B WIN XP WIN7 32bit preferable Mac PC unavailable Manufacturer Manufacturer country Medicore Ltd KOREA 13 Thank you for purchasing the Smart Pulse This product is delivered after passing strict quality control procedures involving rigorous testing If any defects have occurred naturally or during the production of this product and were found to be under the terms of warranty the product will be repaired free of charge from our head office or its distributor However if the product was used improperly inappropriately connected to power or was remodeled or repaired by other service providers other than a Medicore Service Centre or their distributor the product will not be repaired free of charge Medicore Ltd provides free service for one year after the purchase Please provide a paper copy of the warranty when requesting a repair Please follow precautions in the manual Head office 82 2 2056 2629 82 2 2056 2650 E MAIL infol medi core co kr Website http www medi core com 14
16. rement is completed the result will be automatically saved After connecting the device to a PC by the USB cable run the Smart Pulse program on the main screen of the computer When the measurement is completed click on the Register button from the Registry of User Information Amendment Picture 5 after inserting gender user s name and date of birth Then click the User Name from the window on the right side of the screen and click on the RESULT TRANSFER button to move the data saved in the device to computer Please wait until the progress bar disappears since the transfer may take a while When the user is already registered clicking the user s name from the window on the right side of the screen will select the user If the result cannot be to the computer there is a likely a problem with Com Port This will probably be resolved by disconnecting the USB Cable that is connected from the device to the computer and reconnecting it D When the progress bar disappears the measurements have been moved from the device and saved into the computer Save the data to a name of the user by clicking on Move All or Move Selected buttons When the Move all button is selected the saved data will be saved under the name of the selected user Clicking on the Move Selected button causes the selected data to be saved one by one The data can also be saved for more than 2 at a time by selecting all the data at once In
17. stallation a ae The InstallShield Wizard has successfully copied the Silicon Laboratories CP210x YCP Drivers for Windows P 2003 Server Vista v6 4 to your hard drive The driver installer listed below should be executed in order to install drivers or update an existing driver Click Install to begin the installation IF you want to review or change any of your installation settings click Back Click Cancel to exit the wizard Click Finish to complete the Silicon Laboratories CP210 VCP Drivers for Windows XP 2003 Server Vista v6 4 setup E The InstallShield Wizard has successfully copied the Silicon Silicon Laboratories CP210x USB to UART Bridge Dril amp Silicon Laboratories Silicon Laboratories CP210x USB to UART Bridge Driver Version 6 4 3 When the Software installation is completed an icon as shown in the brackets will appear Click the icon fi to start the measurement Please note When the user reinstalls the program the current program must be completely deleted prior to reinstalling the new software If the USB driver is not automatically installed the user can install it manually by the following process My computer Select CD Drive Click right button on a mouse Open CP210xX When the installation is completed read the User Manual which is available by clicking on the top right side of the screen as shown in Picture 3 In order to read the manual the A
18. the accumulated measurement result click on the Accumulated Test Result button from the start screen select a user from the window on the right side of the Registry of User Information Amendment window then click on the NEXT button If the selected user was measured several times click on the NEXT button from Arterial Stress Health Test window to see the additional measurements The more measurements are taken the longer displaying of the accumulated measurement results for viewing will take Clicking on the RESTART button causes the screen to go back to the Start Screen Clicking on the BACK button causes the screen to go back to the User Registration Modification window Precautions during the measurement oF ov Q The user should measure with his her eyes open and should not move or talk during the measurement The device will work normally when the left index finger is inserted deep into the device s holder Do not shake the finger during the measurement After exercising do not measure right away but relax for approximately 10 minutes Breathe normally and do not take deep breaths Put the device on the table to take a stable measurement since we recommended locating the index finger in the device at the same position over the heart Measurement results for people with Arrhythmia or Cardiac disease cannot be trusted Measuring in the morning is desirable The results w
Download Pdf Manuals
Related Search
Related Contents
UNICOM Electric Smart GST-900M User's Manual MCC - IQ SERVIS, as Gebruiksaanwijzing Mode d`emploi 赤経モーターモジュール取扱説明書 TDS-BD-APX500 Hardware User Manual 4265 and 4270 - Adler Instrumentos Samsung SGH-L310 Korisničko uputstvo Module d`alimentation flexible – `FPM75 - Jade 取扱説明書ダウンロード 4 - Cloudfront.net Copyright © All rights reserved.