        Form A6188 - Well Control User Program
         Contents
1.      Note  Depending on the size and complexity of the user program  this process may take several  minutes  When the process ends  the Status field on the Flags screen displays Completed     4  Click Update on the Flags screen  This completes the process of saving your new configuration     Note  For archive purposes  you should also save this configuration to your PC   s hard drive or a  removable media  such as a diskette or a flash drive  using the File  gt  Save Configuration  option on the ROCLINK 800 menu bar     Issued Nov 09 11    Generic Properties Calculations Program User Manual     This page is intentionally left blank       12 Issued Nov 09    Generic Properties Calculations Program User Manual    4 REFERENCE MATERIALS    This section provides additional information plus tables of parameters for the user defined point type  used by the Generic Properties program     Point Type 27  Generic Props    Issued Nov 09    Generic Properties Calculations Program User Manual    4 1 Point Type 27  Generic Props Setup    Point type 27 contains the parameters for configuring the Generic Properties program  There are four logicals of this point type  one logical for  each meter run      Point Type 27  Generic Props Setup    Parm    Name    Point Tag ID    Viscosity    Issued Nov 09    Access    R O    R W    R W    R W    R W    R W    R W    R W    R W    R W    Length    10    Range    0x20   gt  Ox7E for  Each ASCII  character    Any valid floating  point value    Any vali
2.     Active Properties This read only field shows the properties calculation standard currently  Calculation performing property calculations for the selected meter run     8 Issued Nov 09    Field    Generic  Properties       Fluid Phase    Densities      Base    Densities      Flowing       Viscosity       Heating Value       Sp Heat Ratio    Issued Nov 09    Generic Properties Calculations Program User Manual    Description    Sets the status of the Generic Properties program for the selected meter run   Valid selections are Enabled or Disabled     Sets the physical state of the fluid flowing through the selected meter  This  selection is used by the active flow calculation  Valid selections are Gas or Liquid     Sets the density at base conditions  Click    to display the Select TLP screen and  specify the TLP selection used to obtain this value or manually enter a value  The  units are Lb CF or Kg M3     Sets the density at flowing conditions  Click    to display the Select TLP screen  and specify the TLP selection used to obtain this value or manually enter a value   The units are Lb CF or Kg M3     Sets the viscosity  Click l  to display the Select TLP screen and specify the TLP  selection used to obtain this value or manually enter a value  The units are  Lom Ft Sec or Cp     Sets how the system determines the heating value of the gas  Click lto display  the Select TLP screen and specify the TLP selection used to obtain this value or  manually enter a value  The units 
3.   TX 77065 USA VA   Pickering  North Yorkshire UK Y018 7JA EM ERSON f  Website  www EmersonProcess com Remote   j    
4.  on the CD ROM   As Figure 2 shows  the screen  lists all valid user program files with the  BIN extension     Issued Nov 09 3       Generic Properties Calculations Program User Manual    Select User Program File    Look in   E Program Files    de jE     My Documents    Ja    My Computer Filename        men    oni Files of type   User Programs    bin       Cancel         Figure 2  Select User Program File    6  Click Open to select the program file  The User Program Administrator screen displays  As  shown in Figure 3  note that the Download User Program File frame identifies the selected  program and that the Download  amp  Start button is active     User Program Administrator    User Programe Installed in Device  1   Liquid Alloc Mame  No Program  2   Ho Program  Version   Library Yersion    4  Ho Program  BW Cone Flaw Created   DARAM Used      6   No Program CRE  O40 FLASH Used      Entry Pt   Displays      ear   star   stop   Status   Empty    Download User Program File    E  Program Files GenencProperties_ 3  bin    Mame  a   jes Download  amp  Start   Download      Yersion  Rev  1 00   Created  11 75 2009 8 16 59 AM  CAC  OxCO4D   Size   3219    KA                                                                          lt      K   lt    lt           Figure 3  User Program Administrator    Issued Nov 09    Generic Properties Calculations Program User Manual    7  Click Download    Start to begin loading the selected programs  The following message  displays     Confirm 
5. 0 0 0      Manual entry  T L P   parameter that will be copied to  the above Heating Value Parameter     Viscosity of the liquid or gas  This parameter is copied    to the corresponding Meter Run s Viscosity Parameter   TLP  47  X  18      14    Generic Properties Calculations Program User Manual    Point Type 27  Generic Props Setup    de y Name Access ea Length Range Default Description of functionality and meaning of values  10 Viscosity Source TLP R W TLP 3 Any valid floating 0 0 0 Specifies the source TLP for the Viscosity Value  0 0 0  point type TLP   Manual entry  T L P   parameter that will be copied  ce to the above Viscosity Value Parameter   11 Specific Heat Ratio R W FLOAT 4 Any valid floating 1 3 Specific Heat Ratio of the liquid or gas  This parameter  point value is copied to the corresponding Meter Run   s Specific  Heat Ratio Parameter  TLP  47  X  19  for use by the  ee active flow calculation   12 Specific Heat Ratio Source R W TLP 3 Any valid floating 0 0 0 Specifies the source TLP for the Specific Heat Ratio  TLP point type TLP Value  0 0 0   Manual entry  T L P   parameter that  will be copied to the above Specific Heat Ratio  Parameter     Issued Nov 09 Reference 15    Generic Properties Calculations Program User Manual    If you have comments or questions regarding this manual  please direct them to your local sales representative or  contact     Emerson Process Management i   Remote Automation Solutions  lt    Marshalltown  lowa 50158 USA     Houston
6. 07 and its configuration  For more information   refer to the FloBoss 107 Flow Manager Instruction Manual  Form A6206  or the ROCLINK 800  Configuration Software User Manual  for FloBoss 107   Form A6217      1 2 Product Overview    The Generic Properties program for the FB107 disables the on board AGAS properties calculations and  allows you to manually enter gas or liquid properties or copy them from another TLP source  A separate  flow calculation program uses these values for its calculation  Properties that can be manually entered or  copied from another TLP source include base density  flowing density  viscosity  heating value  and  specific heat ratio     1 3 Program Requirements    You download the Generic Properties program to   and then run it from   the Flash and RAM memory  on the FB107  The Generic Properties program is compatible with firmware version 1 21  or greater  of  the FB107  Download and configure the program using the ROCLINK 800 Configuration software   version 1 83 or greater      Program specifics include     ROCLINK    File Name Target Unit  User Defined Flash Used DRAM Used 800 Display  Version Point  UDP   in bytes   in bytes  Verion Number  GenericProperties_3 bin FB107 1 21 27 3155 16384 1 83 28    For information on viewing the memory allocation of user programs  refer to ROCLINK 800  Configuration Software User Manual  for FloBoss 107   Form A6217      Issued Nov 09 1    Generic Properties Program User Manual     This page is intentionally le
7. A  is A AAA AAA a 3  3 Configuration 7  3 1 Generic Properties Setup Screen eurini a a aa a aen a 8  S22    SAVING A UON een a a aea e aa aa a aL 10  4 Reference Materials 13  4 1 Point Type 27  Generic Props Setup     ooooccccnnccccconnnccnnnccnnnnnnnncnnnnnonnononnnnnnnnnnnnnnnnennnnnnnnnnnans 14    Issued Nov 09    Generic Properties Program User Manual     This page is intentionally left blank       Iv Issued Nov 09    Generic Properties Calculations Program User Manual  1 INTRODUCTION    1 1 Scope and Organization    This document serves as the user manual for the Generic Properties program  QERO9Q022   which is  intended for use in a FloBoss 107  FB 107   This manual describes how to download  install  and  configure the Generic Properties user program  referred to as the    Generic Properties program    or    the  program    throughout the rest of this manual   You access and configure this program using  ROCLINK    800 Configuration Software loaded on an IBM compatible personal computer running  Windows   2000  with Service Pack 2   XP  or Vista     The sections in this manual provide information in a sequence appropriate for first time users  Once you  become familiar with the procedures and the software  the manual becomes a reference tool     This manual has the following major sections       Chapter l     Introduction     Chapter 2     Installation     Chapter 3     Configuration    Chapter 4     Reference    This manual assumes that you are familiar with the FB 1
8. Download    2  Download  amp  Start User Program 3      a        Figure 4  Confirm Download    8  Click Yes to begin the download  When the download completes the following message  displays     ROCLINK 800       Figure 5  ROCLINK 800 Download Confirmation    9  Click OK  The User Program Administrator screen displays  see Figure 6   Note that     The User Programs Installed in Device frame identifies the installed program s      The Status field indicates that the program is running     User Program Administrator F  x     User Programe Installed in Device      Liguid Alloc Mame   Generic Properties      Ho Program  3   Generic Properties Version  Aew  1 00 Library Version  Rew  1  No Program Created  11 18 2009 08 16 59 DRAM Used  16384   Y Cone Flow    No Program CRE  Osc040 FLASH Used  3219  Entry Pt  Ox5 C0000    Displays     8    Clear   Start Stop ees Running    Download User Program File    E  Pragram Files  GenericProperties_3 bin Browse         Mame  Generic Properties Download  amp  Start   Download      Yersion  Rev  1 00   Created  11 76 2009 8 16 59 AM  CAC  OxCO4D   Size  3219       Figure 6  User Program Administrator  10  Click Close  The ROCLINK 800 screen displays and the download 1s complete     Issued Nov 09    Generic Properties Calculations Program User Manual     This page is intentionally left blank       6 Issued Nov 09    Generic Properties Calculations Program User Manual    3 CONFIGURATION    After you have loaded the Generic Properties program on 
9. Remote Automation Solutions    Generic Properties Program   for the FloBoss    107     User Manual  QER090022    Form A6287  November 2009         EMERSON     Generic Properties Program User Manual    Revision Tracking Sheet    November 2009    This manual may be revised periodically to incorporate new or updated information  The revision date of each  page appears at the bottom of the page opposite the page number  A change in revision date to any page also  changes the date of the manual that appears on the front cover  Listed below is the revision date of each page  if  applicable      Page Revision  Initial release Nov 09    NOTICE       Remote Automation Solutions     RAS      division of Emerson Process Management shall not be liable for technical or editorial errors in this  manual or omissions from this manual  RAS MAKES NO WARRANTIES  EXPRESSED OR IMPLIED  INCLUDING THE IMPLIED  WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND  IN NO  EVENT SHALL RAS BE LIABLE FOR ANY INCIDENTAL  PUNITIVE  SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING  BUT NOT  LIMITED TO  LOSS OF PRODUCTION  LOSS OF PROFITS  LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING  WITHOUT LIMITATION FOR CAPITAL  FUEL AND POWER  AND CLAIMS OF THIRD PARTIES     Bristol  Inc   Bristol Canada  BBI SA de CV and Emerson Process Management Ltd  Remote Automation Solutions division  UK   are wholly  owned subsidiaries of Emerson Electric Co  doing business as Remot
10. are BTU CF  BTU Lb  MJ M3  or MJ Kg     Sets the specific heat ratio of the gas  defined as the specific heat of the gas at  constant pressure divided by the specific heat of the gas at constant volume    Click    to display the Select TLP screen and specify the TLP selection used to  obtain this value or manually enter a value     Note  Accepted practice for natural gas applications is to use a value of 1 3   which was used to develop the expansion factor tables in the AGA 3  Report     Part 3     5  Proceed to Section 3 2 to save the configuration     Generic Properties Calculations Program User Manual  3 2 Saving the Configuration    Whenever you modify or change the configuration  it is a good practice to save the final configuration to  memory  To save the configuration     1  Select ROC  gt  Flags  The Flags screen displays     Restart Flash Memory    warm Start   Save Configuration      Llear    Cold Start    Cold Start  amp  Clear Alarma E vents   ee      Cold Start  amp  Clear Displays      Cold Start  amp  Clear FST    Cold Start  amp  Clear History      Cold Start  amp  Clear ALL        Update   Y OK   7 Cancel           Figure 9  Flags    2  Click Save Configuration  A verification message displays   ROCLINK 800    2  Perform Flash Memory Save Configuration        Figure 10  Save Verification    10 Issued Nov 09    Generic Properties Calculations Program User Manual    3  Click Yes  When the save process completes  a confirmation message displays     ROCLINK 800  
11. d floating  point type TLP    Any valid floating  point value    Any valid floating  point type TLP    Any valid floating  point value    Any valid floating  point type TLP    Any valid floating  point value    Default    1 0    1 0    0 0 0    1025 0    0 0 0    Description of functionality and meaning of values  Point tag identification  This value is copied from point    type 46  parameter 0     Enables or Disables the Generic Properties Program   O Disable  1 Enable       Specifies the Phase of the Fluid  0 Gas  1 Liquid  This    parameter signals the active flow calculation program  of the Phase of Fluid     Base Density of the liquid or gas  This parameter is  copied to the corresponding Meter Run s Base Density   TLP  47  X  25  for use by the active flow calculation     Specifies the source TLP for the Base Density  0 0 0      Manual entry  T L P   parameter that will be copied to  the above Base Density Parameter     Flowing Density of the liquid or gas  This parameter is    copied to the corresponding Meter Run   s Flowing  Density  TLP  47  X  24  for use by the active flow  calculation     Specifies the source TLP for the Flowing Density  0 0 0      Manual entry  T L P   parameter that will be copied  to the above Flowing Density Parameter     Heating Value of the liquid or gas  This parameter is  copied to the corresponding Meter Run   s Heating  Value  TLP  47  X  17  for use by the active flow  calculation        Specifies the source TLP for the Heating Value  
12. e Automation Solutions     RAS      a division of Emerson Process  Management  FloBoss  ROCLINK  Bristol  Bristol Babcock  ControlWave  TeleFlow and Helicoid are trademarks of RAS  AMS  PlantWeb and  the PlantWeb logo are marks of Emerson Electric Co  The Emerson logo is a trademark and service mark of the Emerson Electric Co  All  other trademarks are property of their respective owners     The contents of this publication are presented for informational purposes only  While every effort has been made to ensure informational  accuracy  they are not to be construed as warranties or guarantees  express or implied  regarding the products or services described herein or  their use or applicability  RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice   All sales are governed by RAS    terms and conditions which are available upon request     RAS does not assume responsibility for the selection  use or maintenance of any product  Responsibility for proper selection  use and  maintenance of any RAS product remains solely with the purchaser and end user           2009 Remote Automation Solutions  division of Emerson Process Management  All rights reserved     ji Issued Nov 09    Generic Properties Calculations Program User Manual    Contents    Page  1 Introduction 1  al   Scope and Organizacion 1  12 o sacle eds ated aceeatae tues aeae 1  ALS  Program Requirements aria litio 1  2 Installation 3  21 Bownoading the OGR
13. ft blank        gt   Issued Nov 09    Generic Properties Calculations Program User Manual    2 INSTALLATION    This section provides instructions for installing the Generic Properties program  Read Section 1 3 of this  manual for program requirements     2 1 Downloading the Program    This section provides instructions for installing the program into the Flash memory on the FB 107     To download the program using ROCLINK 800 software   1  Connect the FB 107 to your computer using the LOI port   2  Start and logon to ROCLINK 800     3  Select Utilities  gt  User Program Administrator from the ROCLINK menu bar  The User  Program Administrator screen displays  see Figure 1      User Program Administrator    User Programe Installed in Device    Mame  Liquid Alloc   2   No Program    3   Ho Program Version  Aew  1 10 Library Version  Rew  2   egin Created  08 31 2009 15 5717 DRAM Used  32768   5  Cone Flow   6   No Program ERE  OCC  FLASH Used  34560  Entry Pt  0540000    Displays  23  24  26  27    _ Clear   Star   Stop   Ghabuz   Running    Download User Program File      Browse         Name     bad      Version    Created    CAC     Size         _             E  Update   Close      Figure 1  User Program Administrator       4  Click Browse in the Download User Program File frame  The Select User Program File screen  displays  see Figure 2      5  Select the path and user program file to download from the CD ROM   Program files are  typically located in the Program Files folder
14. g value   and specific heat ration for the selected meter run     To access this screen   1  Select User Program  gt  Generic Properties   2  Select Display  28  Generic Properties   3  Double click  1  Meter  1  The following Generic Properties Setup screen displays     au ROCLINK 800    Generic Properties Setup Display   FB107        File Edit View ROC Configure Meter Utilities Tools Window Help    Oe Of Y Awl t S2OR8  Point Number   1   Meter  1 a Meter T ag  Meter  1   Meter Description  Meter  1 Description   Active Flow Calculation  l   Cone Active Properties Calculation  Generic Properties    Genenc Properties Fluid Phase  f Enabled    Gas  C Disabled FC    Liquid    Densities  Base   UDP25 1  BADENS E 1 0 Lb CF  Flowing JUDP251  FLDENS El 7 0 Lb CF    Viscosity   Manual   J0 0000063     Lbm Ft Sec  Heating Value  iM anual al 1025 0 BTUACF  Sp Heat Ratio  Manual   1 3      Save As   Auto Scan    2  Update   Close           Figure 8  Generic Properties Setup Screen    4  Review the values in the following fields              Field Description   Point Number Selects the logical number of the meter run to view  Click w to display all defined  instances    Meter Tag This read only field shows the unique identifier for the selected meter    Meter This read only field shows the description of the selected meter    Description   Active Flow This read only field shows the flow calculation standard currently performing flow   Calculation calculations for the selected meter run 
15. the FB107  you configure and monitor the  program using one program specific display  Generic Properties Setup   Use the Generic Propties Setup    screen to enable the program and configure the parameters associated with the Generic Properties  program     You can access the program specific screen from the main ROCLINK 800 screen     vam ROCLINK 800    On Line   Com1   FB107   FB107        File Edit View ROC Configure Meter Utilities Tools Window Help    De sae  SiREVe  Ninh  SPRSORR EL Rl      Ig On Line   Com    FB107   FB107 nas na      ll  Modules       mu 1 0     amp  Control  fy Meter    Me System    History     User Program  Administrator    Liquid Alloc    Generic Properties  El Display  28  Generic Properties   1  Meter  1         Cone Flow    User Display    ell e  d          f                   General   Advanced   1 0 Paints   Meter Points   Diagnostic      Installed Module    CPU Actual Module    CPU   Description    Application Firmware    Revision    Rev 1 20    Part Number   W68182  BuldDate   Jun 23 2008 7 40   Serial Number    W 48083 0022 D E 07460021 Boot Revision    Rev 1 00   Boot Build Date    Nov 17  2006 8 32   Integrity   ATAN    Uninstall       lt       Auto Scan   Update   I Apply  Point Type 27 DRE 1 37PM  gt     Figure 7  ROCLINK 800       Issued Nov 09 1    Generic Properties Calculations Program User Manual    3 1 Generic Properties Setup Screen    Use this screen to enable the Generic Properties program to set the densities  viscosity  heatin
    