         Contents
1.                                                                      6  Arming the System                                                                    6  Split Arming                                                                         7  At Home Arming                                                                   7  Disarming the System                                                                7  Disconnecting from Your Security System                                     8  If an Alarm Sounds                                                                    8  Fire Alarm                                                                            8  Intrusion Alarm                                                                     8  Alarm Memory                                                                          8  Zone Bypassing                                                                       9  Trouble Conditions                                                                    9  Keypad Zones                                                                         10  Quick Arm Feature                                                                   11  Enabling the Quick Arm Feature                                             11  Arming with the Quick Arm Feature                                         14  Door Chime Feature                                                                 11  Enabling the Door Chime                           
2.                             42  Programming Access Codes                                                     12  Fire Alarm Operation                                                                13  Testing Your Security System                                                     14  Bell Test                                                                             14  Zone Testing                                                                       14  Emergency Key Testing                                                        15  Fire Safety in the Home                                                             15  Household Fire Safety Audit                                                       15  Family Escape Planning                                                            16    Maintenance  Limited Warranty    INTRODUCTION    The Escort Voice Assisted Security Control provides easy to understand  English audible information about the status of your security system and  makes operation simple by prompting the user through each operation     The Escort allows any touch tone telephone to act as a keypad for your  security system  This telephone could be any phone that is on the same line  as your security system or an outside telephone which may be used to call the  number of the line to which the security system is connected  Voice messages  guide you through the different operations     Some optional features described in this manual may not be available on yo
3.         Your security system has the capability to be split armed and is currently  armed with this option on the indicated zones  You will not hear this  message if your system does not have this capability        Press star    for options      This message indicates that your security system has options which are  under user s control with the system armed  You will not hear this message  if your system does not have these options  Your installer will inform you of  which are on your system and their operations     Access CODES    When using a telephone to operate your security system  you will use the  same access codes as when using the regular keypad  No additional codes  are required  Your Master Code and other access codes that have been  programmed on your system function exactly as if you were using a regular  keypad  Refer to your system   s instruction manual for further information on  access codes     ARMING THE SYSTEM    To arm your security system using a telephone  first access the system as  explained in the section    Accessing Your Security System       If your system is ready to be armed you will hear the prompt    System  disarmed  enter code to arm system     If you do not hear this prompt or you  hear additional prompts please refer to the    Disarmed Status    section for  further information     Enter your 4 digit access code  You will hear the appropriate prompts from the  following list       Arming system  exit delay in progress      The system is 
4.    to exit      press the     key and you will return to the system status messages     8    ZONE BYPASSING    Use zone bypassing when access is needed to part of the protected area when  the system is armed  Bypassed zones will not cause an alarm  Zones that are  temporarily out of service due to damaged wiring or contacts may be bypassed  to allow system arming with partial protection until repairs can be made     Zones can be bypassed when the system is disarmed  You will hear the  message    System disarmed  enter code to arm system     Then press         You will hear the options menu including the prompt    To bypass zones  press one 1      Press  1      If your system has been programmed to allow bypassing only with an access  code  you will hear the message    Enter access code     Enter your 4 digit access  code  Next you will hear the message    Select zones to bypass     Press the  number of the zone you wish to bypass  You will hear the message    Bypassing  zone       where the message gives the number of each bypassed zone  Pressing  the number of a zone that is bypassed will remove the bypass from that zone        To remove bypassing from all zones  press  0  twice  You will hear the  message    Bypassing no zones    if there are no bypassed zones     Next you will hear the prompt    Press pound     to exit     These messages will  repeat while you are selecting the zone you are bypassing  Press     when  you are finished to return to the status messages     Zo
5.   For security reasons  in some applications the Master Code will not be changeable     With the system disarmed  access the system as described in the    Accessing  Your Security System    section of this manual  When you hear the system  status messages  press the     key    You will then hear the options available from the Options Menu     Select  Options         When the Options Menu is being presented  press the  5  Key  to enter the Access Code Menu     Enter your 4 digit Master Code at the    Enter Master Access Code    prompt   You will then hear    Select a Code  Codes  code numbers  are in use     The  number of each code that is already programmed will be announced  If you  hear    Press nine 9  for more     then press the  9  key to announce which  Access Codes from 9 to 16 are in use     If your system prompted you to    Press nine 9  for more     then codes 1 to 8  can be programmed after they are announced  You must press  9  before you  are able to program codes 9 to 16  Enter the number of the code to be    12    programmed or changed  This number must always be a single digit from 1  to 8  If you have pressed  9  and hear    Codes  9 to 16  are in use    or    No  codes are in use     then press  1 to 8  to program the corresponding codes  from 9 to 16  1   9  2   10  etc    If your system did not prompt you to    Press  nine 9  for more     then enter a two digit number from  01  to  16  after the     Select a code    message     After selecting the code to
6.   One or more zones on your security system are open  Activated zones  must be closed or bypassed before your system can be armed  Refer to  the sections    Arming Your System    and    Bypassing Zones           Alarm in memory  press star    three 3      There has been an alarm on your security system  Press     3  to find  which zone initiated the alarm        System in trouble  press star    two 2       Your security system has a problem which may affect its operation or  which may require service  Press      2  and refer to the section    Trouble  Conditions    to determine which trouble has occurred        System open zone    zone number       The zone or zones indicated by this message are presently open  Open  zones must be closed or bypassed before your system can be armed   Refer to the sections    Arming Your System    and    Bypassing Zones        ARMED STATUS       System armed  enter code to disarm system     Your security system is armed        Warning  zone bypass active     There is at least one zone bypassed  unable to give an alarm  on your  security system        Fire zone trouble     There is a problem with the fire detection circuit on your alarm system         Alarm on zone    Zone number      An alarm has been caused on your security system by the zone or zones  indicated         At home arming active     Your security system is armed with the At home option  Refer to the section     At home Arming           System in split arming  zone    zone number s
7.  be programmed or changed  you will hear the  prompt    Programming Code  code number     to indicate which Access  Code is about to be programmed  The system will announce    Reprogram   ming Code  code number     to indicate which Access Code is about to be  erased and reprogrammed     After the message indicating which code is to be programmed or repro   grammed  you will hear    Enter 4 digit code     Enter 4 digits to program the new  Access Code  do not enter      or     as a digit in an Access Code  To  completely erase a code  enter                 When the code has been pro   grammed  the system will again announce the    Select a Code    message  You  may program another code  or press the     Key to return to the stand by mode     FIRE ALARM OPERATION    When the fire zone is activated  the bell will sound with a pulsing tone   Transmission of the alarm to the monitoring station will be delayed for 30  seconds to allow you to reset the alarm  This delay feature is designed to  reduce the number of false alarms caused by cooking smoke and other  accidental causes  The fire alarm will be transmitted to the monitoring station  only if the alarm is not acknowledged and silenced within 30 seconds     To silence the alarm  access the system following the directions in the    Ac   cessing Your Security System    section of this manual     When you hear the system status  press the     Key to silence the fire alarm   Press the  x  Key and the system will announce     Selec
8.  flame or burning materials to test a smoke detector  Contact your  installer for instructions and information on the safe testing of smoke detectors     14    EMERGENCY KEY TESTING    Note that the Fire  Auxiliary and Panic functions will only work if they are enabled  by your installer  Ensure that your installer informs you of whether or not these  features are active on your system  If they are enabled on your system  you may  test the Fire  Auxiliary and Panic functions by using a telephone     With the system disarmed  access the system with a local phone  After you  hear the status of the system  press and hold the  1  Key for 2 seconds to  initiate a Fire alarm  The bell will sound with a pulsing tone  Enter access code  to silence the alarm  After the Fire alarm function has been tested  perform the  test for the Auxiliary  2  Key and Panic  3  Key     When testing is complete  contact the monitoring station to verify that all  functions worked properly and to inform the monitoring station that you have  completed testing     If any of the system   s functions should fail to work properly  contact your  installer for service     FIRE SAFETY IN THE HOME    Most fires occur in the home and to minimize this danger it is recommended  that a household fire safety audit be conducted and a family escape plan be  developed     HouSEHOLD FIRE SAFETY AUDIT    1 Are all electrical appliances and outlets in a safe condition e g  frayed  cords  over loaded lighting circuits  If y
9.  status messages  press the      Key     You will hear the options available from the Options Menu     Select Op   tions         While the Options Menu is being presented  press the  6  Key to  enter the User Functions Menu  Enter the 4 digit Master Code when you hear     Enter Master Access Code        You will hear the functions available from the User Function Menu     User  Function Menu         Press the  6  Key to select the    Select Chime on or off     function  The  6  Key works like a switch to turn the Door Chime feature on and  off  With the Door Chime feature turned off  pressing the  6  Key will enable it   You will hear    Chime on     When the Door Chime feature is enabled  pressing  the  6  Key will shut it off  You will hear    Chime off        After either enabling or disabling the Door Chime feature  press the     Key to  return to the stand by mode     PROGRAMMING ACCESs CODES    You may program the Access Codes used to arm and disarm your system  A  4 digit Access Code can be assigned to each user of the system  and the  codes can be customised to make them easy to remember  Note that an  Access Code is like the key to a lock  the security of your system depends on  maintaining the secrecy of your Access Codes  Under no circumstance  should a system user ever reveal their Access Code to anyone     You may program up to 15 Access Codes in addition to the Master Code  Your  installer will inform you if you are able to change the Master Code on your system 
10.  user may find the following booklet prepared by the FCC helpful     How to Identify and Resolve    Radio Television Interference Problems     This booklet is available from the U S  Government Printing Office   Washington  D C  20402  Stock   004 000 00345 4     IMPORTANT INFORMATION    NOTIFICATION TO TELEPHONE COMPANY Upon request  the customer shall notify the telephone company  of the particular line which the connection will be made  and provide FCC registration number and the ringer  equivalence of the protective circuit     FCC Registration Number  FS3CAN 75252 KX N  Ringer Equivalence Number  0 1B    MALFUNCTION OF THE EQUIPMENT In the event that this equipment should fail to operate properly  the  customer shall disconnect the equipment from the telephone line to determine if it is the customer   s equipment which  is not working properly  or if the problem is with the telephone company network  If the problem is with this  equipment  the customer shall discontinue use until it is repaired     TELEPHONE CONNECTION REQUIREMENTS Except for the telephone company provided ringers  all  connections to the telephone network shall be made through standard plugs and telephone company provided  jacks  or equivalent  in such a manner as to allow for easy  immediate disconnection of the terminal equipment   Standard jacks shall be so arranged that  if the plug connected there is withdrawn  no interference to the operation  of the equipment at the customer   s premises which re
11. TM          Voice Assisted  Security Control    INISTESIUL N TIO  I AV  UNIOPNE    SOFTWARE VERSION 1 0R    FCC COMPLIANCE STATEMENT    CAUTION  Changes or modifications not expressly approved by Digital Security Controls Ltd  could void your  authority to use this equipment     This equipment generates and uses radio frequency energy and if not installed and used properly  in strict  accordance with the manufacturer   s instructions  may cause interference to radio and television reception  It has  been type tested and found to comply with the limits for Class B device in accordance with the specifications in  Subpart    B    of Part 15 of FCC Rules  which are designed to provide reasonable protection against such interfer   ence in any residential installation  However  there is no guarantee that interference will not occur in a particular  installation  If this equipment does cause interference to television or radio reception  which can be determined by  turning the equipment off and on  the user is encouraged to try to correct the interference by one or more of the  following measures       Re orient the receiving antenna     Relocate the alarm control with respect to the receiver     Move the alarm control away from the receiver     Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits    If necessary  the user should consult the dealer or an experienced radio television technician for additional  suggestions  The
12. and still have all of those devices ring when your telephone number is called   In most  but not all areas  the sum of the REN   s of all devices connected to one line should not exceed five  5   To  be certain of the number of devices that you may connect to your line  you may want to contact your local  telephone company     EQUIPMENT MAINTENANCE FACILITY  Digital Security Controls Ltd  160 Washburn St Lockport  NY 14094    TABLE OF CONTENTS    l    Page  Introduction                                                                             2  About Your Security System                                                        D  Fire Detection                                                                       2  Monitoring                                                                           3  General System Operation                                                      3  Accessing your Security System                                                  4  Local Access                                                                       4  Remote ACCESS                                                                    4  Answering Machine Override                                                  4  System Status                                                                          4  Disarmed Status Messages                                                    5  Armed Status                                                                       5  Access Codes     
13. armed but will not respond to an opening of the designated  exit door during the delay period        Quick arming system       This message indicates that the system was armed by pressing     0O    Refer to the section    Quick Arming           To clear interior zones bypass  press star    one 1       Your system may have zones designated as Home Away  These zones will  automatically bypass when you arm the system  To re activate the Home   Away zones press     1       At home arming  exit delay in progress       Your system has been armed by pressing     9   Refer to the section    At   home Arming        6    SPLIT ARMING    If your installer has enabled the split arming option on your control panel  then  you will need to know which codes have been assigned to each system  When  armed with this option you will hear    System in split arming  zone    zone  numbers armed     indicating that the system is split and which zones are now  armed        AT HOME ARMING    If you At home Arm your system  the entry delay on the designated exit entry  door is removed so that anyone entering while you are at home will immedi   ately sound an alarm     You can At home Arm by pressing      You will hear a message list that  includes    Press nine 9  for at home arming     Press  9   The system will  prompt you to    Enter access code     Enter your 4 digit access code  You will  then hear the message    At home arming  exit delay in progress        DISARMING THE SYSTEM    7    If you ret
14. e ground level  an approved fire ladder or rope  should be provided as well as training in its use     Exits on the ground level should be kept clear  e g  remove snow from  exterior patio doors     The family should have a predetermined assembly point where every   one can be accounted for  e g  across the street or at a neighbours     Once everyone is out of the house call the Fire Department     A good plan emphasizes quick escape  Do not investigate first or  attempt to fight the fire and do not attempt to rescue valuables or other  belongings as this takes up valuable time  Once outside  do not re   enter the house  Wait for the fire department     Write the plan down and rehearse frequently so that should an emer   gency arise  everyone will know what they are to do  Revise the plan  as conditions change  e g  more or fewer family members or changes  to the house        Make sure your fire warning system is operational by conducting  weekly tests as noted elsewhere in this manual  If you are unsure  about system operation  contact your installing dealer     It is recommended that you contact your local fire department and  request further information on home fire safety and escape planning  If  available  have your local fire prevention officer conduct an in house  fire safety inspection     MAINTENANCE    With normal use  the system requires minimum maintenance  The following  points should be observed     1 Do not wash the security station with a wet cloth  Light dust
15. he system with a local  phone  When you hear the status of the system  press the  2  Key and hold it  for 2 seconds  You will hear a tone and then the message    Auxiliary alarm         3  Panic To sound a Panic Alarm  access the system with a local phone  When  you hear the status of the system  press the  3  Key and hold it for 2 seconds   If your system has been programmed for a silent panic alarm  you will hear  nothing further  If the panic alarm is not programmed to be silent  then you will  hear a tone and then the message    Panic alarm    and the bell siren will sound        10    Quick ARM FEATURE    When the Quick Arm feature is enabled  the system may be armed by enter   ing     O  instead of an Access Code  Note that the      0  command will only  arm the system  it will not disarm the system  The Quick Arm feature can be  used to allow a person  such as a baby sitter  to arm the system without  having to be provided with an Access Code        ENABLING THE QUICK ARM FEATURE    With the system disarmed  access the system as described in the    Accessing  Your Security System    section of this manual  While you are listening to the  status of the system  press the      Key     You will hear the options available from the Options Menu     Select Op   tions         While the Options Menu is being announced  press the  6  Key to  enter the User Functions Menu  You will then hear    Enter Master Access  Code     Enter the 4 digit Master Code     You will hear the func
16. ing with a  barely damp cloth should remove normal accumulations of dust     2  The battery bell test is designed to determine battery condition  however it is  recommended that the stand by batteries be replaced every three years     3 For other system devices such as smoke detectors  passive infrared   ultrasonic or microwave motion detectors or glassbreak detectors  consult  the respective manufacturer s literature for testing and maintenance     LIMITED WARRANTY    Digital Security Controls Ltd  warrants that for a period of twelve months from  the date of purchase  the product shall be free of defects in materials and  workmanship under normal use and that in fulfillment of any breach of such  warranty  Digital Security Controls Ltd  shall  atits option  repair or replace the  defective equipment upon return of the equipment to its factory  This warranty  applies only to defects in parts and workmanship and not to damage incurred  in shipping or handling  or damage due to causes beyond the control of  Digital Security Controls Ltd  Such as lightning  excessive voltage  mechani   cal shock  water damage  or damage arising out of abuse  alteration or  improper application of the equipment        The foregoing warranty shall apply only to the original buyer  and is and shall  be in lieu of any and all other warranties  whether expressed or implied and of  all other obligations or liabilities on the part of Digital Security Controls Ltd   This warranty contains the entire wa
17. lly review the Family Escape Planning guidelines in this manual     Note  Your installer must enable the fire detection portion of this equipment  before it becomes functional     2    3         important Note    A security system cannot prevent emergencies  It is only intended to alert you  and  if included  a monitoring station of an emergency situation  Security  systems are generally very reliable but they may not work under all conditions  and they are not a substitute for prudent security practices or life and property  insurance  Your security system should be installed and serviced by qualified  security professionals who should instruct you on the level of protection that  has been provided and on system operation           MONITORING    This system is capable of transmitting alarms  troubles  and emergency  information over telephone lines to a monitoring station  If you inadvertently  initiate an alarm  immediately call the monitoring station to prevent an unnec   essary response     Note  The monitoring function must be enabled by the installer before it  becomes functional     GENERAL SYSTEM OPERATION    Your security system is made up of a DSC control panel  one or more regular  keypads  the Escort  and various detectors and sensors  The DSC control  panel will be mounted out of the way in a utility room or basement  The metal  cabinet contains the system electronics  Escort Voice Assisted Security Con   trol  fuses and stand by battery  There is normally no rea
18. mains connected to the telephone network shall occur by reason  of such withdrawal     INCIDENCE OF HARM Should terminal equipment or protective circuitry cause harm to the telephone network   the telephone company shall  where practicable  notify the customer that temporary disconnection of service may  be required  however  where prior notice is not practicable  the telephone company may temporary discontinue  service if such action is deemed reasonable in the circumstances  In the case of such temporary discontinuance  the  telephone company shall promptly notify the customer and will be given the opportunity to correct the situation   The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted     CHANGE IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES The Telephone Company may make  changes in its communications facilities  equipment  operations or procedures  where such actions is reasonably  required and proper in its business  Should any such changes render the customer   s terminal equipment incompat   ible with the telephone company facilities the customer shall be given adequate notice to the effect of the  modifications to maintain uninterrupted service     GENERAL This equipment should not be used on coin telephone lines  Connection to party line service is subject  to state tariffs     RINGER EQUIVALENCE NUMBER  REN  The REN is useful to determine the quantity of devices that you  may connect to your telephone line 
19. ne bypasses are automatically removed each time the system is disarmed  and must be reapplied before the next arming  For security reasons your  installer may program the system to prevent the bypass command from  operating on certain zones     TROUBLE CONDITIONS    The control panel continuously monitors a number of possible trouble condi   tions  If one of these conditions occurs  the regular keypad will beep twice  every ten seconds  There is no indication on a telephone until the system is  accessed     Access your security system as described  If your system is armed  only one  trouble will be indicated in the system status messages  If you hear    Fire  zone trouble     then there is a problem with the fire detection circuit of your  system     If a trouble is present while your system is disarmed  you will hear the status  message    System in trouble  press star    two 2      Press      and you will  hear the options list  including    For system troubles press two 2      Press   2  and then you will hear the applicable messages from the following list        Battery trouble      Indicates a low or disconnected stand by battery      AC power trouble      Indicates that your security system has lost AC power        Day zone trouble      Indicates a trouble on a 24 hour zone        Phone line trouble      Indicates a problem with the telephone line con   nected to your system        Fail to communicate trouble      Indicates that your security system has  attempted to c
20. ommunicate with the monitoring station and failed        Bell or siren trouble      Indicates that there is a problem with your bell siren  or its wiring        Fire zone trouble      Indicates a problem with the fire detection circuit of your  system        Reset clock time trouble      Indicates that the internal clock on your system  needs to be reset        No system trouble      Indicates that there are no troubles on your system at  this time        Press pound    to exit    Pressing     will return you to the system status  messages     Note  A trouble condition reduces the security your system is designed to  provide  Call your installing company for service     KEYPAD ZONES    Three emergency use functions are available from a local telephone  When  you have access to the system  a Fire  Auxiliary or Panic alarm can be initiated  with the press of a single key     Note that these functions will not work unless they are enabled by your  installer or if you have accessed your security system from a remote phone   Ensure that your installer informs you whether or not these functions are  enabled on your security system      1  Fire To sound a Fire Alarm  access the system with a local phone  When  you hear the status of the system  press the  1  Key and hold it for 2 seconds   You will hear a tone and then the message    Fire alarm     The bell will sound  and the alarm will be transmitted to the monitoring station      2  Auxiliary To sound an Auxiliary Alarm  access t
21. ompt    Enter access code      Enter a valid access code within 15 seconds or the system will hang up   The system will also hang up if an incorrect code is entered     e Once a valid access code has been entered  you will hear a message  or  sequence of messages  giving the current status of your security system     ANSWERING MACHINE OVERRIDE    If an answering machine is on the same telephone line as your security  system  the answering machine must be set to answer between 2 to 8 rings     If you call from an outside telephone to access your security system  the  answering machine will answer the call  Within 15 seconds press              Do not wait for the message on the answering machine to finish  Your answer   ing machine will be disconnected from the line and your security system will  announce the system status     SYSTEM STATUS    There are two groups of status messages  one provides information on the  system when it is disarmed and the other when it is armed  You will hear at  least one status message when you access the system  The Escort will then  provide as many messages from the following lists as are necessary to  describe the current status of your security system     4    5    DISARMED STATUS MESSAGES       System disarmed  enter code to arm system     Your security system is ready to be armed        Warning  zone bypass active     There is at least one zone bypassed  unable to give an alarm  on your  security system        Secure system before arming    
22. ou are uncertain about the  condition of your electrical appliances or household service  have a  professional evaluation     2 Are all flammable liquids stored safely in closed containers in a well  ventilated cool area  Cleaning with flammable liquids should be avoided     3 Are fire hazardous materials  matches  well out of reach of children     4 Are furnaces and wood burning appliances properly installed  clean and  in good working order  Have a professional evaluation     15    FAMILY ESCAPE PLANNING    There is often very little time between the detection of a fire and the time it  becomes deadly  It is thus very important that a family escape plan be  developed and rehearsed     1 Every family member should participate in developing the escape plan     2 Study the possible escape routes from each location within the house    and since many fires occur at night  special attention should be given to  the escape routes from sleeping quarters     3  It is essential that escape from a bedroom be possible without opening    16    the interior door  To facilitate such an escape   e Make sure that doors and or windows that open to the outside are    easily opened  e g  not painted shut     If opening the exit  or simply getting to the exit may be too difficult for  children  the elderly or handicapped  plans for rescue should be  developed  This includes making sure that those who are to perform  the rescue can promptly hear the fire warning signal     If the exit is above th
23. rranty  Digital Security Controls Ltd   neither assumes  nor authorizes any other person purporting to act on its  behalf to modify or to change this warranty  nor to assume for it any other  warranty or liability concerning this product     In no event shall Digital Security Controls Ltd  be liable for any direct or  indirect or consequential damages  loss of anticipated profits  loss of time or  any other losses incurred by the buyer in connection with the purchase   installation or operation or failure of this product     WARNING    Digital Security Controls Ltd  recommends that the entire system be com   pletely tested on a regular basis  However  despite frequent testing  and due  to  but not limited to  criminal tampering or electrical disruption  it is possible  for this product to fail to perform as expected        1993  2000 Digital Security Controls Ltd   Toronto  Canada   www dsc com    Printed in Canada 29000474 R1    
24. s in  a pulsing mode  follow your emergency evacuation plan immediately  See  guidelines for family escape planning in this manual     INTRUSION ALARM    If an intrusion alarm sounds  continuous bell siren   an intruder may be on the  premises  Go to a safe place immediately  If you are certain that the premises  are safe  the alarm may be silenced from a telephone but you will first have to  access your system as described previously  Transmission to the monitoring  station will not be interrupted by silencing the alarm unless a transmission  delay was put in by your installer  If the alarm was unintentional  notify the  monitoring station or local authorities immediately     You can determine the source of the alarm by following the instructions in the     Alarm Memory    section  Once the source of the alarm has been corrected   your system can be armed again        ALARM MEMORY    Your security system is designed to store in memory alarms that occurred  while the system was armed  If there has been an alarm while the system was  armed  then you will hear the message    Alarm in memory  press star     three 3     when the system is disarmed  Press      and you will hear    For zone  memory  press  3     along with the other messages  Press  3  and you will  hear    Alarm on zone       to indicate the zone s  that were in alarm  If you  press     3  and there are no alarms in memory  you will hear the message     Memory is clear     When you hear the message    Press pound 
25. son for anyone but  the installer or service person to have access to the control panel     The security system has several zones or areas of protection and each of  these zones will have one or more detection sensors connected to it  motion  detectors  glassbreak detectors  door contacts or shock sensors         The regular keypad is an important part of your security system  It is used to  send commands to the system and display system status  Even though a  telephone via the Escort can be used to operate your system  the telephone  will not automatically display or indicate system status or zones in alarm  It is  essential  therefore  that a regular keypad be placed in a location that is  accessible by all users of the security system and that it be checked regularly  for any changes in system status     ACCESSING YOUR SECURITY SYSTEM    LOCAL ACCESS   Use this procedure to access your security system from a telephone that is on  the same line as your security system  No dialing is necessary    e Pick up the telephone  You will hear a dial tone     e Press               The dial tone will stop  Then you will hear a message  or  sequence of messages  giving the current status of your security system     REMOTE ACCESS    e Dial the number of the telephone line to which your security system is  connected  Your security system will answer the call after 8 rings     e Press              within 15 seconds or the system will hang up     e You will hear three beeps and then the pr
26. t Options           The system will describe the options available from the Options Menu  When  the Options Menu is being presented  press the  4  Key to reset the smoke  detectors  When the  4  Key is pressed  the system will announce    Sensor  Reset    to indicate that the smoke detectors are being reset     If the smoke detector that caused the alarm is clear of smoke  the system will  return to normal when the detector is reset     If the smoke detector is not clear of smoke  an alarm will sound again after 90  seconds  You may silence the alarm and reset the detector again following  the instructions above  The sensor reset procedure can be repeated as many  times as necessary until the cause of the alarm is corrected  If a smoke  detector frequently goes into alarm for unknown reasons  contact your in   staller for service or possible relocation of the detector    13       Important Note  If the fire alarm is a false alarm and you suspect that the  alarm has been transmitted to the monitoring station  call the monitoring  station immediately to avoid an unnecessary response  If you are not  sure if there is a fire condition or not  or if the fire alarm sounds at night   follow your evacuation plan immediately     TESTING YOUR SECURITY SYSTEM    It is recommended that you test your security system weekly  To test your  system  first call the monitoring station and inform them that you are about to  test your system     BELL TEST    With the system disarmed  access the s
27. tions available from the User Functions Menu     User  Function Menu         Press the  4  Key to select the    Select Quick Arm on or  off    function  The  4  Key works like a switch to turn the Quick Arm feature on  and off  With the Quick Arm feature turned off  pressing the  4  Key enable it  and you will hear    Quick Arm on     When the Quick Arm feature is enabled   pressing the  4  Key will disable it and you will hear    Quick Arm off        After either enabling or disabling the Quick Arm feature  press the     Key to  return to the stand by mode     ARMING WITH THE QUICK ARM FEATURE    Access the system as described in the    Accessing Your Security System     section of this manual  When you hear the system status messages  press      then  0  to arm the system  The system will announce    Quick Arming System        Door CHIME FEATURE    When the Door Chime feature is enabled  a series of beeps will sound from the  system s keypad when certain zones are opened or closed  your installer  must configure the zones which are to be used with the Door Chime feature   The Door Chime can be used to indicate the opening and closing of a door   such as a back door  that is not always in sight  Note that the Door Chime  feature  when enabled  only operates when the system is disarmed     ll    ENABLING THE DOOR CHIME    With the system disarmed  access the system as described in the    Accessing  Your Security System    section of this manual  While listening to the system 
28. ur  security system  You will not hear the voice prompts for any option that you do  not have on your system     In this manual  the voice messages are printed in bold and enclosed in  quotes  e g     Warning  zone bypass active     When instructed to press a  key or keys to perform an operation  the symbol for that key s  will be  enclosed in square brackets  e g       2      ABOUT YOUR SECURITY SYSTEM    Your DSC security equipment has been designed to give you the greatest  possible flexibility and convenience  The Escort will guide you through each  operation with English language voice prompts  However to fully benefit from  the features of your security system you should read this manual and the  instruction manual provided with your system very carefully  Have your in   staller instruct you on system operation and on which features have been  implemented on your system  All users of this system should be equally  instructed in its use  Fill out the System Information page in the Instruction  Manual and store it and this manual in a safe place for future reference     FIRE DETECTION    This equipment is capable of monitoring fire detection devices such as smoke  detectors and providing a warning alarm if a fire condition is detected  Good  fire detection depends on having adequate numbers of fire detectors placed  in appropriate locations  This equipment should be installed in accordance  with N F P A  standard  74  N F P A  Batterymarch Park  Quincey MA 02269    Carefu
29. urn to find that an alarm has occurred while you were away  it is  possible that an intruder may still be on the premises  Do not enter  Go to the  nearest telephone and contact the authorities     To disarm your security system using a telephone  first access the system as  explained in the section    Accessing Your Security System        If your system is armed you will hear the prompt    System armed  enter code  to disarm system     If you hear additional prompts please refer to the    Armed  Status    section for further information     Enter your 4 digit access code  You will hear    Disarming system     If there  were no alarms while the system was armed you will also hear    No alarm in  memory     When the system is disarmed you will hear additional prompts   Please refer to the    Disarmed Status    section for further information     DISCONNECTING FROM YOUR SECURITY SYSTEM    Pressing           will disconnect the telephone from your security system  when using an in house or outside phone     You will also be disconnected from the security system if no key is pressed for  two minutes  An in house telephone  on the same line as the security system   can be hung up to disconnect without pressing               Note  If an outside phone is hung up without pressing            the security  system will remain on the line for two minutes causing a busy signal     IF AN ALARM SOUNDS    FIRE ALARM    If your system has been installed with fire detectors and the alarm sound
30. ystem with a local phone as de   scribed in the    Accessing Your Security System    section of this manual  When  you hear the system status  press the   gt   Key     The system will describe the options available from the Options Menu which  starts with    Select Options        When the Options Menu is being presented   press the  6  Key to enter the User Functions Menu  The system will prompt  you to    Enter Master Access Code     After entering your 4 digit Master Code   you will hear    User Function Menu        The system will describe the functions  available from the User Function Menu  When the User Function Menu is  being presented  press the  8  Key to test the bell and keypad buzzer     When the  8  Key is pressed  the system will announce    Bell test active     The  bell and all keypad buzzers will sound for 2 seconds        ZONE TESTING    To ensure that all zones are working properly and the system is correctly  announcing all zones  perform the following test     With the system disarmed  access the system with a local phone  The system  will announce    System disarmed  enter code to arm system        Have someone activate each zone one at a time by walking in motion detector  areas  or by opening doors and windows that are monitored with contacts   Ensure that the system announces the opening of each zone with the mes   sage    System open zone  zone number         Test smoke detectors only by following the manufacturer   s instructions  Never  use an open
    
Download Pdf Manuals
 
 
    
Related Search
 English  english to spanish  english to russian  english to french  english to japanese  english to german  english  english to korean  english to tamil  english to spanish translation  english to italian  english to chinese  english to hindi  english to tagalog  english to marathi  english to latin  english to arabic  english to tagalog translator  english bulldog  english to telugu  english to vietnamese  english to spanish google translate  english to polish  english alphabet  english breakfast  english language 
    
Related Contents
User`s Manual Advantech RISC SOM  4. - Konica Minolta  Manual do utilizador BT-03i  取扱説明書ダウンロード(PDF)  Model 2200  516 05 00 Rev0 Folheto de Instruções Depilador Corpus 2  EnviroMon User's Guide  Pelco WS5000 User's Manual  EXSYS USB 2.0 for 3.5 SATA II  Le dossier scientifique quadriennal 2008-2011 - Crisco    Copyright © All rights reserved. 