1. c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 5 Enable Shade Control Group 3 Parameter Number 15 Parameter Size 1 The device can operate shade control devices via Group 3 if this parameter is activated inactive Default LED Transmission Indication Parameter Number 19 Parameter Size 1 defines the behavior of the LED when transmitting data o homeros Poll Group 2 Interval Parameter Number 20 Parameter Size 1 defines the poll interfal for group 2 if polling is activated 1 255 Interval Default 2 Poll Group 2 Parameter Number 22 Parameter Size 1 defines if Group 2 shall be polled or not o dont poll poll Default Command Classes Supported Command Classes Basic version 1 Association version 1 Version version 1 All Switch version 1 Configuration version 1 Manufacturer Specific version 1 Multilevel Switch version 1 c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 6 Technical Data Power Supply 230V Attachable Loads ohmic loads up to 300 W IP Rating IP 20 Frequency 868 42 MHz Wireless Range Explorer Frame Support Yes SDK 4 54 00 Device Type Slave with routing capabilities Generic Device Class Multilevel Switch Specific Device Class Multilevel Power Switch Routing Yes Explanation of Z
2. controls Z Wave associated devices only If the insert is mounted correctly pushing the upper part of the left or right paddle will turn ON the load Pushing the lower part of the left or right paddle will turn OFF the electric load Pressing and holding the switch will allow dimming and brightening of Z Wave dimmers if associated LED Control The LED on the TZ65 D will turn on when the load attached is off to act as a night light However the LED can be user configured to turn on when the load attached is on The TZ65 D will flicker its LED when it is transmitting to any of its 4 groups This can be changed if desired See oeLED transmission indication s Associations a Z Wave devices control other Z Wave devices The relationship between one device controlling another device is called association In order to control a different device the controlling device needs to maintain a list of devices that will receive controlling commands These lists are called association groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireless command Association Groups Tap left paddle once max nodes in group 5 Tap right paddle once max nodes in group 5 Tap right paddle twice max nodes in group 5 every switching command max nodes in group 5 Configuration Parameters Z Wav
3. TKB Home Z Wave Bria Paddle Wall immer TKBHOME Firmware Version 1 3 Quick Start ES This device is a Z Wave actuator To include the device into the network turn the controller into the inclusion mode and then press the upper or lower part of the paddle of the device The device is now ready to work Please refer to the chapters below for detailed information about all aspects of the products usage What is Z Wave This device is equipped with wireless communication complying to the Z Wave standard Z Wave is the international standard for wireless communication in smart homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated remote controls R This results in a number of possible communication patterns within a Z Wave network that are partly or completely supported by a specific device 0 00 NTN OO 1 Controllers control actuators 2 Actuators report change of status back to cont
4. Wave specific terms Controller is a Z Wave device with capabilities to manage the network Controllers are typically Gateways Remote Controls or battery operated wall controllers Slave is a Z Wave device without capabilities to manage the network Slaves can be sensors actuators and even remote controls Primary Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of bringing new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product does not contain hazardous chemicals c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 7 Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the
5. cannot be assured the voltage supply has to be interrupted immediately and the equipment has to be protected from unintended operation Installation Guidelines The TZ65 D wall mounted dimmer needs a pattress box with 230 V power wires for installation It does not fit into European wall boxes with 60 mm diameter c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 2 1 To install the wall dimmer first remove the paddle using a small screw driver 2 Afterwards remove the four screws through the retaining ring holding the trim ring to the mounting plate This will allow the removal of the trim ring When removing the trim ring make sure not to bend or disrupt the shape of the antenna wire 3 Wire the product according to the schematics The two wired from the mains distribution panel are directly connected to the inserts contacts N and L The contact L is the switched load output and needs to be connected to the cable of the load 4 Install the product in the wall box 5 Reinstall the trim ring and the retaining ring with the four screws Mind the arrow on the inserts top side showing the mounting direction of the insert 6 Return the switching paddle by pushing it into the mounting frame Make sure the LED window is also towards the stamped word oeBottom on the retaining ring LOAD NEUTRAL LINE TZ66D Behavior within the Z Wave netw
6. e products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features IMPORTANT Controllers may only allow to configure signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example to set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 4 Start Level Bit Parameter Number 1 Parameter Size 1 defines if the start level bit shall be ignores when transmitting a dim command to a dimmer o lwe dont ignore Default Suspend Group 4 Parameter Number 2 Parameter Size 1 defines if the Association group 4 shall be active or not o yes Default Night Light Parameter Number 3 Parameter Size 1 Activates Night Light o LED blinks on activity Default Night Light active Invert Switch Parameter Number 4 Parameter Size 1 Inverts Switching on is upper part o dont invert Default Enable Shade Control Group 2 Parameter Number 14 Parameter Size 1 The device can operate shade control devices via Group 2 if this parameter is activated o inactive Default
7. groundwater and get into the food chain damaging your health and well being c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 8
8. ntrol The left paddle controls the local load while the right paddle remotely controls Z Wave associated devices only The association of further Z Wave devices needs to be done by a Z Wave controller The unit is powered by 230V and needs a pattress box with 230 V power wires for installation The unit is shipped completely with electronics switching paddle and mounting frame in arctic white HomePro style which can be replaced by another mounting frame of the HomePro switching series The unit is designed for use within a 3 wire system which means that a neutral wire blue is needed for operations Attention The Switch does not fit in a german 60mm pattress box Before Device is installed Please read carefully the enclosed user manual before installation of the radio actuator in order to ensure an error free functioning ATTENTION only authorized technicians under consideration of the country specific installation guidelines norms may do works with 230 Volt mains power Prior to the assembly of the product the voltage network has to be switched off and ensured against re switching The product is permitted only for proper use as specified in the user manual Any kind of guarantee claim has to be forfeited if changes modifications or painting are undertaken The product must be checked for damages immediately after unpacking In the case of damages the product must not be operated in any case lf a danger free operation of the equipment
9. ork 1 On factory default the device does not belong to any Z Wave network The device needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode this device can join or leave the network Leaving the network i e being excluded sets the device back to factory default If the device already belongs to a network follow the exclusion process before including it in your network Otherwise inclusion of this device will fail If the controller being included was a primary controller it has to be reset first The device is included and excluded by a single click on the switch when the controller is in inclusion resp exclusion mode Operating the device c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 3 The actuator can be set to control other Z Wave devices and is operated by the local switching paddles or wirelessly using Z Wave commands The left paddle controls the local load while the right paddle remotely
10. roller 3 Sensors report change of status of measured values to controller c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 1 4 Sensors directly control actuators 5 Actuators control other actuators 6 Remote controls send signals to static controllers to trigger scenes or other actions 7 Remote controls control other actuators There are two different role a controller can have There is always one single primary controller that is managing the network and including excluding devices The controller may have other functions like control buttons as well All other controllers don t manage the network itself but can control other devices They are called secondary controllers The image also shows that its not possible to operate a sensor just from a remote control Sensors only communicate with static controllers Product description The TZ65 D dual wall switch is switching attached loads and is controlled either by the local switching paddle or remotely via the Z Wave wireless protocol It is included and controlled in a Z Wave network by a remote control a wireless control centre or any other kind of Z Wave controller including a PC software Beside the local switch the unit can control other Z Wave units remotely in up to three additional Z Wave groups which are associated with this device Tipping one time or two times the switching paddle performs the co