Home
Pacer DA40 User Manual
Contents
1. 95 Krif Road Page 12 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com Miltronics Mfg Inc 95 Krif Road Keene New Hampshire 03431 USA 800 283 1141 603 352 0187 Fax 603 352 1036 sales miltronics com www miltronics com www pacer instruments usa com Copyright 2009 2013 Miltronics Mfg Inc Miltronics AT400 TAT420 THT500 and the Miltronics Mfg Inc logo are trademarks of Miltronics Mfg Inc THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com Citron 95 Krif Road Page 1 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com _ THT 500 TEMPERATURE HUMIDITY TRANSMITTER User Manual THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com Mittron l 95 Krif Road Page 2 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com Warranty This product is fully warranted against defective materials and or workmanship for a period of one year after purchase provided it was not improperly used For your protection please use this pro
2. all custom length cables for the THTS00 must be ordered at the time the transmitter is purchased or the unit must be returned for calibration The maximum length for probe cables is 150 ft please consult manufacturer if longer cable is required Cable grips will seal on round cables from 2 5 to 6 5mm diameter For wire bundles if you wish to insure water tightness use RTV silicon or other sealant safe for electronics at end of cable grip Notes THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com 95 Krif Road Page 8 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com APPENDIX A No Longer Available APPENDIX B Collecting data by means of resident Hyper Terminal program on Win 95 98 NT4 and Win 2000 PC s A Set up Communication Port 1 Find and open HyperTerminal under Accessories and Communications 2 Type a name like Humidity Transmitter and select an icon then click OK 3 In the Connect using box select a COM port probably COM 1 Click OK B Set up COM 1 Properties 1 Set Bits per second to 1200 2 Set Data bits to 8 3 Set Parity to None 4 Set Stop bits to 1 5 Set Flow control to None 6 Click OK
3. the select Save C Connect cable and transfer data 1 Connect the RS 232 cable to COM 1 port 2 Power up transmitter 3 Select Call from Call menu Data will fill window 4 To stop select Disconnect from Call menu 5 To save data select Save As and give file a name D To transfer to Excel 1 Select data file from C5 above and open with Notepad 2 Select data to be transferred and Copy 3 Open a new blank Excel worksheet select Paste 4 Select entire Column A Under Data menu select Text to columns and click Next 5 Follow directions to separate data then click Finish THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com 95 Krif Road Page 5 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com INSTALLATION AND SETUP FOR THTS00 Note Make all connections with Power Off Remove cover to attach Transmitter to mounting area and to attach power and signal cables Attach in location free of physical dangers such as excessive heat or continuous condensing moisture Note Terminals 13 15 are not installed on any transmitter TERMINAL CONNECTIONS 123 45 6 7 8 9 10111213 14 15 VOOSODOSDSVOVSGOOY OOOoOo0oo0ooOoOo000000 1 4 20 mA temp 9 220 VAC 2 0 1 Volt temp
4. 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com SPECIFICATIONS Sensors Humidity sensor Capacitive Thin Film Temperature PT100 RTD Range Relative Humidity 5 to 95 RH Temperature 4 to 176 F 20 to 80 C Accuracy Relative Humidity 2 RH Temperature 40 5 C Resolution optional display Relative Humidity 0 1 RH Temperature 0 1 For C Response Time Relative Humidity 90 of final value in 15 sec Temperature Approximately 60 seconds Analog Outputs separate and concurrent Relative Humidity 0 1V 0 5V and 4 20mA represent 0 100 RH Temperature 0 1V 0 5V and 4 20mA represent 4 to 176 F 20 to 80 C Operating Range 4 to 176 F 20 to 80 C Power Supply 120 or 220V AC 50 60Hz also 10 30 VDC Input Current with all options 10 30VDC 38mA 110VAC 18mA 220V AC 9mA Output Impedance 0 1V and 0 5V outputs 1KO Enclosure ABS plastic NEMA Class 4 Dimensions Housing 4 8 x 4 8 x 2 2 Probe 4 5 x 1 diameter Weight 18 ounces Options Sintered metal filter Harsh environments THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com 95 Krif Road Page 9 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com In order to insure the proper calibration
5. THTS00 10 110 VAC 3 0 5 Volt temp 11 220 110 VAC 4 4 20 mA air velocity 12 No Connection 5 0 5 Volt air velocity 13 No Connection 6 0 1 Volt air velocity 14 No Connection 7 Ground 15 No Connection 8 V 10 30 VDC POWER HOOKUP la Ifusing 110VAC power hook white neutral wire into slot 10 Then hook black hot wire into slot 11 lb If using 220VAC power hook either hot wire into slot 11 Then hook the other hot wire into slot 9 Ic Ifusing 10 30VDC first hook ground wire into slot 7 Then hook V wire into slot 8 THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com 95 Krif Road Page 6 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com RH OUTPUT 2a If you want 0 1V FS hook output ground reference to slot 7 Then hook RH output wire to slot 6 2b If you want 0 5V FS hook output ground reference to slot 7 Then hook RH output wire to slot 5 2c If you want 4 20mA FS hook output ground reference to slot 7 Then hook RH wire to slot 4 TEMPERATURE OUTPUT 3a If you want 0 1V FS hook output ground reference to slot 7 Then hook temperature output wire to slot 3 3b If you want 0 5V FS hook output ground reference to slot 7 Then hook temperature output wire to slot 2 3c If you want 4 20mA FS hook output ground reference
6. to slot 7 Then hook temperature output wire to slot 1 MOUNTING THE PROBE Mount at location where measurements are to be made Do not change the length of the cable supplied at purchase as doing so will change the calibration Protect the probe with a sintered metal filter optional if dust or spray is present METRIC OR ENGLISH UNITS Shown on the diagram but no longer available REPLACING COVER Use care not to damage the seal if the cover has a display use proper polarity when reinstalling connectors see Diagram 1 DISPLAY SWITCH Shown on the diagram but no longer available NOTE Be sure to tighten screws above slots when finished THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com 95 Krif Road Page 7 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com Diagram 1 Location and Polarity of Connectors and Switches Temperature 4 330 Display and humidity 11 cm Connector 23 4 Connections Metric or Front cover Note Processor switch and other English Switch items on left of board are present Units Connector only when RS 232 and or display Switch options are present THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com
7. duct as soon as possible If returned it must be securely wrapped sent prepaid and insured to Miltronics Mfg Inc 95 Krif Road Keene NH 03431 PH 603 352 3333 FX 603 352 4444 Please include a note with name address telephone number and description of the problem Although we provide assistance on Pacer Instruments amp Miltronics products both personally and through our literature it is still the total responsibility of the customer to determine the suitability of the product for use in their application This manual is provided by Miltronics Mfg Inc without any kind of warranty Precautions have been taken in accurately preparing this manual however we neither assume responsibility for any omissions or errors that may appear nor assume liability for any damages that result from the use of the products in accordance with the information contained in the manual THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com MAittron l 95 Krif Road Page 11 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com Notes THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com 95 Krif Road Page 10 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sale
8. s pacer instruments usa com or sales miltronics com Notes THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com 95 Krif Road Page 3 of 12 Keene NH 03431 800 283 1141 or 800 828 9089 Fax 603 352 4444 or 603 352 1036 sales pacer instruments usa com or sales miltronics com INTRODUCTION The THTS500 humidity temperature transmitters supply accurate humidity and temperature THT500 data from a room or process air source on a continuous basis to a computer chart recorder printer meter or control circuit The AT400 and TAT420 air velocity transmitters supply accurate air velocity and TAT420 temperature data from a building or process airflow on a continuous basis to a computer chart recorder printer and meter or control circuit Every instrument has terminals for both DC and AC power and 0 1V 0 5V and 4 20mA outputs The outputs are concurrent and can accept multiple wires depending on the gauge used The humidity or humidity temperature probe can be mounted on the instrument enclosure or at a remote location that choice must be made at the time of purchase The probe can be fitted with a optional sintered metal filter for dusty or harsh environments THT500 User Manual Miltronics Mfg Svcs Inc Rev 1 2 www pacer instruments usa com 06 Sept 2013 www miltronics com 95 Krif Road Page 4 of 12 Keene NH 03431 800 283 1141 or
Download Pdf Manuals
Related Search
Related Contents
Modelo 380940 - Extech Instruments MP5 Navy 取扱説明書 Operating instructions Kicker 2009 CompVT Truck Sub Box Owner's Manual WARTUNGSPLAN KURZANLEITUNG VEHICLE ALARM SYSTEM `GN6I` User manual. Bedienungsanleitung IC-DPR5 取扱説明書 HP Deskjet 3520 e-All-in-One Printer Setup Poster Copyright © All rights reserved.