Home
Energy Navigator Setup Manual tcm135
Contents
1. O Yes No A Sampling possible by default rule No A Displays power consumption when there is setpoint gap based on CT value A Displays power consumption when there is setpoint gap based on CT value Sampling possible by default rule Q Available A Some functions available x Unavailable Commissioning Manual Energy Navigator Setup EM11A028 DCM601A51 intelligent Touch Manager You need the outdoor unit address to use Energy Navigator Configure the outdoor unit address in advance see the intelligent Touch Manager Installation Manual EM11A016 EM11A018 For information on how the administrator can configure and use the function refer to the appropriate sections of the User Manual The remaining part of this manual provides the procedures for commissioning See i 5 intelligent Touch Manager Installation Configure the outdoor unit address Manual EM 1A016 EM11A018 D F 7 Commissioning Manual Configure the model type of the outdoor unit EM11A021 EM11A022 SS Commissioning Manual Supplementary Volume Commissioning for Power Proportional Distribution Commissioning for Power Proportional Distribution EM11A027 w Log into the service mode D Configure the source from which to obtain the room temperature This manual a Configure the month when to start data collection w Configure an additional energy conversion type When necessary Commissioning Manu
2. confirmation dialog box that appears touch the Yes button to save the settings and restart iTM Data Clear Energy Navigator Setup Room temperature settings Modify Setting of start month to collect data Modify Settings by energy conversion type Modify Data Clear 1 1 Clear ME You can clear the trend data as needed Touch the Clear button 11 On the confirmation dialog box that appears touch the Yes button to clear the data and restart iTM 13 Commissioning Manual Energy Navigator Setup EM11A028 DCM601A51 intelligent Touch Manager DAIKIN INDUSTRIES LTD Head office Umeda Center Bldg 2 4 12 Nakazaki Nishi Kita ku Osaka 530 8323 Japan Tokyo office JR Shinagawa East Bldg 2 18 1 Konan Minato ku Tokyo 108 0075 Japan DAIKIN EUROPE N V Zandvoordestraat 300 B 8400 Oostende Belgium EM11A028 203 HT
3. from this list which shows management point names along with their current settings Specify whether to use the suction temperature or analogue input Ai as the source of the room temperature by selecting either of the two radio buttons under Room temperature settings 4 If you have chosen Ai touch the Modify button to bring up the Ai Selection window Commissioning Manual Energy Navigator Setup EM11A028 10 DCM601A51 intelligent Touch Manager Ai Selection 4 1 00 Mgmt point list Name Detailed Type i ai 1 Internal Ai i ai 2 Internal Ai i ai 3 Internal Ai er a Select your desired Ai management point from the list and then touch the OK button to return to the Room temperature settings window The selection you made using the radio button group 4 is saved when you touch the Modify button 5 The list 3 is updated to reflect the change Repeat the steps above to configure all of the indoor unit management points When you are done touch the OK button to save the settings and return to the Energy Navigator Setup window Configure the month when to start data collection To configure the month when to start data collection use the following procedure Energy Navigator Setup B Room temperature settings Modify B Setting of start month to collect data 6 Modify EI Settings by energy conversion type Modify MB Data Clear Clear EE Touch the Modify button 6 to bring up th
4. DAIKIN ee Commissioning Manual Supplementary Volume intelligent Touch Manager Energy Navigator Setup Model DCM601A51 Contents Energy Navlaator SGT pisses ceases cccteen EDE SEE Dene GE ee DR Gewese 2 Log into the service MOPS se RE EE EG eg ee ie ee EE DE EE EE Ee Ge Gee 7 e Configure the source from which to obtain the room temperature ese ee ee ee ee ee 9 e Configure the month when to start data collection ee ee ee ee ee eenen 11 e Configure an additional energy conversion type see ee RA AA ee ee ee ee ee 12 SO RE EA OE AE EE ONE AA AE OE TE 13 DCM601A51 intelligent Touch Manager Energy Navigator Setup Energy Navigator assists equipment administrators in implementing systematic operations management by analyzing the operational status of the equipment formulating energy saving plans establishing equipment operations standards necessary to achieve energy saving goals Energy Navigator consists of the following four main functional areas Function Summary Budget Actual Energy Management visualizes the yearly and monthly progress of the actual energy consumption goals with respect to the planned energy consumption and also provides functionality to compare the actual energy consumption of the current year with that of the previous year 1 Budget Actual Energy Management JoyeBinen AB1euzg Equipment Operations Management identifies and visualizes any equ
5. al Energy Navigator Setup EM11A028 6 DCM601A51 intelligent Touch Manager Log into the service mode Display the Menu List screen Touch the four corners of the screen in the indicated order The Password Input dialog appears Emergency auto Timer Stop Chandagver Extension Schedule Mon 23 01 Close Ed Missing AEL 5 SEEN J Ee ee Ea EJ 7 Commissioning Manual Energy Navigator Setup EM11A028 DCM601A51 intelligent Touch Manager Enter the service password daikin and touch the OK button to log into the SE Mode AIC AutoRegist a DII NET Engineering Close and log into the SE Mode gt lt Mgmt Pnt DataRegist Dealer Activation Option a W Contact Into Outdoor Setup ee AE Changeover Option Service Login Time Zone History Mgmt AN Lv Other Setting Furthermore if the screen is locked entering the service password instead of the administrator password after carrying out the special operation indicated below allows you to unlock the screen Commissioning Manual Energy Navigator Setup EM11A028 DCM601A51 intelligent Touch Manager Configure the source from which to obtain the room temperature Configure the source from which to obtain the room temperature that will be displ
6. ans Legend Yes x No Legend Available A Available in part x Unavailable 3 Commissioning Manual Energy Navigator Setup EM11A028 DCM601A51 intelligent Touch Manager The following table describes how the availability of each of Budget Actual Management and Equipment Operations Management depends on the engineering details Engineering details Availability of Availability energy Energy budget actual management function Energy budget actual visualization function Monthly Energy 9y 8 Annual ener Monthly ener t consumption Pa anergy mager ee puaget Year to year energy of meters consumption ia actual visualization actual visualization estimation function comparison function plan function function Yes Yes O O Yes No N A O Ens ee can pe Available by manually visualized by manually entering the actual entered he ave energy consumption energy consumption O A Available by manually entering the actual energy consumption Engineering details Energy budget actual management function DORN Availability of Energy Actual energy EE EE Availability energy consumption consumption Energy Group of meters consumption plan registration registration registration function Energy type Energy Conven plan function function registration factor registration function function O O O O O O O Creation of group to which to manually enter th
7. ayed on the Operational Status graph on the Detailed View screen accessible from Energy Navigator s Failure to Turn Off sampling screen and Setpoint Gap sampling screen Detailed View screen operational state Detailed View 1 1 01 Operation status Date of occurrence a Back 09 06 2012 Sat Next gt j 24 Hour BA gt D lt gag M Mgmt Pnt AIC Other AutoRegist DataRegist Activation Time Zone History Mgmt Setting CO A Net Za Navi DIIII NET Changeover Engineering Option Energy Contact Into Outdoor Setup Navigator Service Login Close Touch the Energy Navigator button 1 to bring up the Energy Navigator Setup window 9 Commissioning Manual Energy Navigator Setup EM11A028 DCM601A51 intelligent Touch Manager Energy Navigator Setup B Room temperature settings 2 Modify _ Setting of start month to collect data Modify E Settings by energy conversion type Modify E Data Clear Clear Touch the Modify button 2 to bring up the Room temperature settings window Room temperature settings Mgmt point list Room temperature settings Detailed Type suction Temp Suction Temp Suction Temp Suction Temp Suction Temp IS Suction Temp Suction Temp Suction Ti Suction Ti ad The Mgmt point list box 3 provides a list of registered indoor unit management points Select your desired management point
8. e Month to Collect Data Setup window 11 Commissioning Manual Energy Navigator Setup EM11A028 DCM601A51 intelligent Touch Manager Month to Collect Data Setup Start month for yearly collecting data EE From the Start month for yearly collecting data combo box 7 select the month January through December when to begin collecting the data for use on the annual budget actual management graph Touch the OK button On the confirmation dialog box that appears touch the Yes button to save the settings and restart iTM Configure an additional energy conversion type You can configure an additional energy conversion type for use in Budget Actual Energy Management as needed Energy Navigator Setup B Room temperature settings Modify _ Setting of start month to collect data Modify Settings by energy conversion type 8 Modify E Data Clear Clear Touch the Modify button 8 to bring up the Energy Conversion TypeSetup window Commissioning Manual Energy Navigator Setup EM11A028 12 DCM601A51 intelligent Touch Manager Energy Conversion TypeSetup 9 Name ABC Unit 1 0 Oi Modify 1000 10 Modify 1000000 100 Modity ME Fill in the Name 9 and Unit 10 fields and specify the x1 000 and x1 000 000 units To fill in each field use a text input dialog box that appears when you touch the Modify next to the field When you are done touch the OK button On the
9. e actual energ consumption O Creation of group to which to manually enter the actual energy consumption Yes Yes O Yes No C Q Available AN Some functions available x Unavailable Commissioning Manual Energy Navigator Setup EM11A028 DCM601A51 intelligent Touch Manager Engineering details Equipment operation management Trial Power Proportional Distribution Operation rules Operation rule creation Sampling period target setup function function Sampling period setup function Sampling target setup function Yes Yes O O Yes No No Yes No No Engineering details O O O O O O Equipment operation management Trial Power Proportional Distribution Operation rules Failure to turn off sampling function Failure to turn off sampling result display function Detailed display function Yes Yes O Yes No A Sampling possible by default rule No A Displays power consumed during failure to turn off based on CT value Engineering details A Displays power consumed during failure to turn off based on CT value Sampling possible by default rule Equipment operation management Trial Power Proportional Distribution Operation rules Setpoint gap sampling function Setpoint gap sampling function Detailed display function Yes Yes
10. ipment operations plans Visualize based on CT values how the energy consumption is affected by deviations of in house air conditioners from operations plans 2 Ability to perform budget actual management of the whole energy consumed by the building and to ensure that equipment operations comply with operations plans O Budget actual energy management with watt hour meters A Identify deviation from equipment operations plans Visualize based on CT values how the energy consumption is affected by deviations of in house air conditioners from operations plans 3 Ability to perform extensive energy management of equipment systems that are among the largest energy consumers in the building as well as air conditioners that have great opportunities for operational improvement Manage actual energy consumption based on billing statements O Identify deviation from equipment operations plans Visualize the waste of energy due to deviations of in house air conditioners from operations plans 4 Ability to perform budget actual management of the whole energy consumed by the building and to efficiently achieve energy saving goals O Budget actual energy management with watt hour meters O Identify deviation from equipment operations plans Visualize the waste of energy due to deviations of in house air conditioners from operations pl
11. ipment systems that are or were running during the hours when they are supposed to stop and any air conditioners that are running beyond the set temperature range set forth as part of the air conditioner operations plans 2 Equipment Operations Management Identification of deviation from operations plans Data Export allows you to export measurement data to a CSV 3 Data Export format so that you can perform advanced analysis on the data using external software Commissioning allows you to configure settings necessary to take 4 Commissioning the advantage of Energy Navigator This function is available in the service mode only Energy Navigator can address various needs but depending on how your equipment is engineered such as whether or not watt hour meters are installed and whether or not the commissioning process for Power Proportional Distribution has been completed Commissioning Manual Energy Navigator Setup EM11A028 2 DCM601A51 intelligent Touch Manager What is needed Engineering details Overview of available functionality Availability of Meters installed Trial Power Proportional Distribution Budget Actual Energy Management Equipment Operations Management Equipment administrator 1 Ability to easily gain visibility into the operational status of the equipment A Manage actual energy consumption based on billing statements A Identify deviation from equ